most frequently cited serious violations fy2015 - construction

25
OSHA Federal Standards October 1, 2014 – September 30, 2015

Upload: lythu

Post on 02-Jan-2017

227 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: Most Frequently Cited Serious Violations FY2015 - Construction

OSHA Federal Standards

October 1, 2014 – September 30, 2015

Page 2: Most Frequently Cited Serious Violations FY2015 - Construction

NUMBER OF SERIOUS VIOLATIONS – FY 2015

29

CFR

19

26

.

MOST FREQUENTLY CITED SERIOUS VIOLATIONS IN CONSTRUCTION 2015

2

19

26

Ove

rall MFC

FALL PROTECTION – RESIDENTIAL CONSTRUCTION

PORTABLE LADDERS NOT EXTENDED 3 FEET ABOVE LANDING

FALL PROTECTION – UNPROTECTED SIDES & EDGES

FALL PROTECTION – TRAINING

EYE AND FACE PROTECTION

HEAD PROTECTION

SCAFFOLDS – FALL PROTECTION

AERIAL LIFTS – FALL PROTECTION

SAFE ACCESS

FALL PROTECTION – ROOFING WORK ON LOW-SLOPED ROOFS

29

CFR

19

26

SU

BPA

RTS

638

711

764

780

1183

1219

1347

1370

1514

4060

451(e)(1)

501(b)(10)

453(b)(2)(v)

451(g)(1)

100(a)

503(a)(1)

102(a)(1)

501(b)(1)

1053(b)(1)

501(b)(13)

ML

LL

EE

MM

XM

Page 3: Most Frequently Cited Serious Violations FY2015 - Construction

NUMBER OF SERIOUS VIOLATIONS – FY 2015

29

CFR

19

26

.

72

124

281

434

632

28(a)

25(a)

20(b)(1)

21(b)(2)

20(b)(2)

GENERAL SAFETY & HEALTH [1926.20 – .35]

3

EMPLOYEE TRAINING PROGRAMS

PERSONAL PROTECTIVE EQUIPMENT – EMPLOYER RESPONSIBILITY

INITIATE AND MAINTAIN ACCIDENT PREVENTION PROGRAMS

INSPECTIONS BY A COMPETENT PERSON

SUB

PAR

T C

HOUSEKEEPING

Page 4: Most Frequently Cited Serious Violations FY2015 - Construction

NUMBER OF SERIOUS VIOLATIONS – FY 2015

29

CFR

19

26

. 23

23

27

28

29

47

50(g)

62(d)(2)(v)(B)

62(d)(2)(v)(C)

51(f)(1)

62(d)(2)(v)(E)

62(d)(1)(i)

OCCUPATIONAL HEALTH & ENVIRONMENTAL CONTROLS [1926.50 – .66]

4

WASHING FACILITIES FOR HARMFUL CONTAMINANTS

LEAD – BIOLOGICAL MONITORING

EMERGENCY EYEWASH/SHOWER

LEAD – CHANGE AREAS PROVIDED PRIOR TO EXPOSURE ASSESSMENT

LEAD – PROTECTIVE CLOTHING & EQUIPMENT PROVIDED PRIOR TO EXPOSURE ASSESSMENT

SUB

PAR

T D

LEAD – DETERMINING EXPOSURE AT OR ABOVE ACTION LEVELS

Page 5: Most Frequently Cited Serious Violations FY2015 - Construction

NUMBER OF SERIOUS VIOLATIONS – FY 2015

29

CFR

19

26

.

12

18

229

1183

1347

96

102(a)(2)

95(a)

100(a)

102(a)(1)

PERSONAL PROTECTIVE & LIFE SAVING EQUIPMENT [1926.95 – .107]

5

EYE AND FACE PROTECTION

HEAD PROTECTION

PPE – PROVIDED USED & MAINTAINED

SUB

PAR

T E

FOOT PROTECTION

REQUIRED EYE & FACE PROTECTION – ANSI REQUIREMENTS

Page 6: Most Frequently Cited Serious Violations FY2015 - Construction

NUMBER OF SERIOUS VIOLATIONS – FY 2015

29

CFR

19

26

.

17

19

22

23

42

150(c)(1)(viii)

150(a)(4)

150(c)(1)(iv)

150(c)(1)(vi)

150(c)(1)(i)

2A FIRE EXTINGUISHER PROVIDED PER 3000 SQFT OF BUILDING AREA

EXTINGUISHERS WITH 50FT OF 5 GALLONS OF FLAMMABLE LIQUIDS

PROVIDING FIRE EXTINGUISHER NOT RATED LESS THAN 2A FOR EACH FLOOR

FIRE PROTECTION & PREVENTION [1926.150 – .159]

6

SUB

PAR

T F

PORTABLE FIRE EXTINGUISHERS INSPECTED PERIODICALLY & MAINTAINED

INSPECTION & MAINTENANCE OF FIRE FIGHTING EQUIPMENT

Page 7: Most Frequently Cited Serious Violations FY2015 - Construction

NUMBER OF SERIOUS VIOLATIONS – FY 2015

29

CFR

19

26

.

2

5

15

22

23

200(c)(1)

200(a)

201(a)

200(g)(2)

200(g)(1)

SIGNS, SIGNALS & BARRICADES [1926.200 – .203]

7

TRAFFIC SIGNS AT POINTS OF HAZARD

TRAFFIC CONTROL SIGNS/DEVICES

FLAGGERS - SIGNALING

SUB

PAR

T G

USE OF CAUTION SIGNS

VISIBILITY OF SIGNS AND SYMBOLS

Page 8: Most Frequently Cited Serious Violations FY2015 - Construction

NUMBER OF SERIOUS VIOLATIONS – FY 2015

29

CFR

19

26

.

9

11

15

16

19

250(a)(1)

251(a)(2)(i)

251(b)(1)

251(a)(1)

252(a)

MATERIALS STORED TO PREVENT SLIDING FALLING, OR COLLAPSE

MATERIALS HANDLING, STORAGE, USE & DISPOSAL [1926.250 – .252]

8

GENERAL RIGGING EQUIPMENT IDENTIFICATION

EXTERIOR DROP CHUTES

RIGGING EQUIPMENT INSPECTION & REMOVAL FROM SERVICE

WELDED ALLOY STEEL CHAIN SLING IDENTIFICATION

SUB

PAR

T H

Page 9: Most Frequently Cited Serious Violations FY2015 - Construction

NUMBER OF SERIOUS VIOLATIONS – FY 2015

29

CFR

19

26

.

29

35

35

57

121

304(f)

300(b)(2)

304(h)(1)

304(d)

300(b)(1)

TOOLS: HAND & POWER [1926.300 – .307]

9

GUARDING OF ROTATING/MOVING PARTS

GUARDING OF CIRCULAR HAND-HELD RIPSAWS

TOOLS DESIGNED FOR GUARDS – GUARDS IN PLACE

GUARDING OF PORTABLE CIRCULAR SAWS

WOODWORKING TOOLS – ANSI REQUIREMENTS

SUB

PAR

T I

Page 10: Most Frequently Cited Serious Violations FY2015 - Construction

NUMBER OF SERIOUS VIOLATIONS – FY 2015

29

CFR

19

26

.

4

5

11

16

26

350(a)(7)

350(h)

351(b)(4)

350(a)(10)

350(a)(9)

WELDING & CUTTING [1926.350 -.354]

10

SECURING OF CYLINDERS WHILE IN USE

REGULATORS AND GAUGES SHALL BE IN PROPER WORKING ORDER

CYLINDERS SECURED UPRIGHT

OXYGEN CYLINDER STORAGE

USING CABLES NEEDING REPAIR

SUB

PAR

T J

Page 11: Most Frequently Cited Serious Violations FY2015 - Construction

NUMBER OF SERIOUS VIOLATIONS – FY 2015

29

CFR

19

26

.

153

167

174

215

282

403(b)(2)

404(b)(1)(i)

405(g)(2)(iv)

416(e)(1)

404(f)(6)

ELECTRICAL [1926.400 – .449]

11

EQUIPMENT INSTALLATION AND USE

USE OF GFCI OR ASSURED GROUNDING PROGRAM

GROUNDING PATH

WORN/FRAYED CORDS AND CABLES

FLEXIBLE CORD STRAIN RELIEF

SUB

PAR

T K

Page 12: Most Frequently Cited Serious Violations FY2015 - Construction

NUMBER OF SERIOUS VIOLATIONS – FY 2015

29

CFR

19

26

.

400

573

638

764

780

451(g)(1)(vii)

451(b)(1)

451(e)(1)

453(b)(2)(v)

451(g)(1)

SCAFFOLDS [1926.450 – .454]

12

FULL PLANKING

PROTECTION BY PFAS OR GUARD RAIL SYSTEM

FALL PROTECTION

AERIAL LIFTS – FALL PROTECTION

SAFE ACCESS

SUB

PAR

T L

Page 13: Most Frequently Cited Serious Violations FY2015 - Construction

NUMBER OF SERIOUS VIOLATIONS – FY 2015

29

CFR

19

26

.

536

711

1219

1370

4060

501(b)(11)

501(b)(10)

503(a)(1)

501(b)(1)

501(b)(13)

FALL PROTECTION [1926.500 – .503]

13

ROOFING WORK ON LOW-SLOPED ROOFS

ROOFING WORK ON STEEP ROOFS

RESIDENTIAL CONSTRUCTION

UNPROTECTED SIDES & EDGES

FALL HAZARD TRAINING

SUB

PAR

T M

Page 14: Most Frequently Cited Serious Violations FY2015 - Construction

NUMBER OF SERIOUS VIOLATIONS – FY 2015

29

CFR

19

26

.

2

4

15

552(b)(8)

552(c)(1)

552(a)(1)

HELICOPTERS, HOISTS, ELEVATORS, AND CONVEYORS [1926.550 – .556]

14

HOISTS & ELEVATORS – COMPLYING WITH MANUFACTURER’S RECOMMENDATIONS

HOISTS & ELEVATORS – MATERIAL HOIST SHALL CONFORM WITH ANSI A10.5-1969

HOISTS & ELEVATORS – ENCLOSURES FOR HOIST TOWERS OUTSIDE OF STRUCTURE

SUB

PAR

T N

Page 15: Most Frequently Cited Serious Violations FY2015 - Construction

NUMBER OF SERIOUS VIOLATIONS – FY 2015

29

CFR

19

26

.

17

19

34

40

47

602(c)(1)(viii)(A)

602(c)(1)(vii)

602(c)(1)(vi)

602(c)(1)(ii)

602(d)

MOTOR VEHICLES, MECHANIZED EQUIPMENT, & MARINE OPERATIONS [1926.600 – .606]

15

INDUSTRIAL TRUCK OPERATOR TRAINING

INDUSTRIAL TRUCKS ANSI B56.1-1969 REQUIREMENTS

MODIFICATIONS THAT AFFECT CAPACITY RATING

SAFE RIDING SPACE ON INDUSTRIAL TRUCKS

SAFETY PLATFORM SECURED TO CARRIAGE OR FORKS

SUB

PAR

T O

Page 16: Most Frequently Cited Serious Violations FY2015 - Construction

NUMBER OF SERIOUS VIOLATIONS – FY 2015

29

CFR

19

26

.

55

159

173

242

512

651(k)(2)

651(j)(2)

651(k)(1)

651(c)(2)

652(a)(1)

EXCAVATIONS [1926.650 – .652]

COMPETENT PERSON - INSPECTION AND EMPLOYEE REMOVAL

COMPETENT PERSON - INSPECTIONS

PROTECTION FROM FALLING/ROLLING MATERIALS AND EQUIPMENT

SAFE EGRESS

CAVE-IN PROTECTION

SUB

PAR

T P

Page 17: Most Frequently Cited Serious Violations FY2015 - Construction

NUMBER OF SERIOUS VIOLATIONS – FY 2015

29

CFR

19

26

.

4

4

5

5

147

702(i)(1)

703(a)(2)

703(b)(1)

706(b)

701(b)

CONCRETE & MASONRY CONSTRUCTION [1926.700 – .706]

17

REINFORCING STEEL GUARDING

SHORING EQUIPMENT SHALL BE INSPECTED PRIOR TO ERECTION

MASONRY WALL OVER 8 FEET SHALL BE BRACED

SEMICIRCULAR MASONRY SAW GUARDING

LOCKOUT/TAGOUT OF BULK CEMENT STORAGE FACILITIES

SUB

PAR

T Q

Page 18: Most Frequently Cited Serious Violations FY2015 - Construction

NUMBER OF SERIOUS VIOLATIONS – FY 2015

29

CFR

19

26

.

7

8

13

23

118

760(c)(3)

760(b)(1)

760(b)(3)

761(b)

760(a)(1)

STEEL ERECTION [1926.750 – .761]

18

UNSECURED DECKING IN CDZ EXCEEDING 3,000 SQFT.

PROTECTION FROM FALL HAZARDS MORE THAN 2 STORIES OR 30 FEET

PROTECTION FROM FALL HAZARDS

FALL HAZARD TRAINING

FALL PROTECTION FOR CONNECTION

SUB

PAR

T R

Page 19: Most Frequently Cited Serious Violations FY2015 - Construction

NUMBER OF SERIOUS VIOLATIONS – FY 2015

29

CFR

19

26

.

1

1

1

2

2

800(d)

800(g)(3)

800(g)(5)(ii)

800(b)(3)

800(q)(2)

UNDERGROUND CONSTRUCTION, CAISSONS, COFFERDAMS, AND COMPRESSED AIR [1926.800 – .804]

19

DESIGNATED PERSON STATION ABOVE GROUND

5-PERSON RESCUE TEAMS FOR JOBSITES LESS THAN 25 EMPLOYEES

CONTROLLING ACCESS TO UNDERGROUND BY UNAUTHORIZED PERSONNEL

INSPECTION OF DRILLING AREA BEFORE DRILLING OPERATIONS STARTS

EMPLOYEES INSTRUCTED ON RECOGNITION AND AVOIDANCE OF HAZARDS UNDERGROUND

SUB

PAR

T S

Page 20: Most Frequently Cited Serious Violations FY2015 - Construction

NUMBER OF SERIOUS VIOLATIONS – FY 2015

29

CFR

19

26

.

3

4

4

6

49

850(g)

850(b)

851(b)

850(c)

850(a)

DEMOLITION [1926.850 – .860]

20

REMOVAL OF STRUCTURAL OR LOAD-SUPPORTING MEMBERS

SHORING AND BRACING OF WALLS AND FLOORS

ENGINEERING SURVEY PRIOR TO DEMOLITION OPERATIONS

UTILITIES SHUT OFF OR CAPPED BEFORE DEMOLITION OPERATIONS

OPEN WALLS PROTECTED BY A HEIGHT OF 42 INCHES

SUB

PAR

T T

Page 21: Most Frequently Cited Serious Violations FY2015 - Construction

NUMBER OF SERIOUS VIOLATIONS – FY 2015

29

CFR

19

26

.

1

2

2

950(b)(3)

960(c)(1)(iii)(B)

962(b)(3)

POWER TRANSMISSION AND DISTRIBUTION [1926.950 – .968]

21

INSULATION ON THE ENERGIZED PART

SUB

PAR

T V

NO INDUCED VOLTAGES

SUPERVISION AND ANNUAL INSPECTION

Page 22: Most Frequently Cited Serious Violations FY2015 - Construction

NUMBER OF SERIOUS VIOLATIONS – FY 2015

29

CFR

19

26

.

22

ROPS ON EQUIPMENT MANUFACTURED ON OR AFTER SEPT 1, 1972

SUB

PAR

T W

ROLLOVER PROTECTIVE STRUCTURE; OVERHEAD PROTECTION [1926.1000 – .1003]

1 11000(B)

Page 23: Most Frequently Cited Serious Violations FY2015 - Construction

NUMBER OF SERIOUS VIOLATIONS – FY 2015

29

CFR

19

26

.

150

244

276

364

1514

1051(a)

1060(a)

1053(b)(13)

1053(b)(4)

1053(b)(1)

STAIRWAYS AND LADDERS [1926.1050 – .1060]

23

USING TOP STEP AS A STEP

STAIRWAY OR LADDER PROVIDED AT BREAK IN ELEVATION ON 19 INCHES

PORTABLE LADDER – 3 FEET ABOVE LANDING SURFACE

APPROPRIATE USE

LADDER & STAIRWAY HAZARD TRAINING

SUB

PAR

T X

Page 24: Most Frequently Cited Serious Violations FY2015 - Construction

NUMBER OF SERIOUS VIOLATIONS – FY 2015

29

CFR

19

26

.

12

15

18

29

30

1101(e)(1)

1101(k)(3)(i)

1101(f)(1)(i)

1101(f)(2)(i)

1101(k)(9)(i)

TOXIC & HAZARDOUS SUBSTANCES [1926.1100 – .1152]

24

ASBESTOS – EXPOSURE MONITORING

CLASS I, II, AND III WORK IN REGULATED AREA

ASBESTOS – EXPOSURE ASSESSMENT BY A COMPETENT PERSON

ASBESTOS – IDENTIFY PRESENCE, LOCATION & QUANTITY OF ACM/PACM

ASBESTOS – TRAINING PROGRAM

SUB

PAR

T Z

Page 25: Most Frequently Cited Serious Violations FY2015 - Construction

NUMBER OF SERIOUS VIOLATIONS – FY 2015

29

CFR

19

26

.

8

8

9

10

15

1417(c)(1)

1428(a)

1424(a)(2)(ii)

1412(e)(1)

1412(f)(1)

CRANES AND DERRICKS IN CONSTRUCTION [1926.1400 – .1442]

25

MONTHLY INSPECTION OF EQUIPMENT

MAINTAIN BARRIERS AROUND HAZARD AREA

EQUIPMENT INSPECTION EVERY 12 MONTHS

SIGN PERSON QUALIFICATIONS

OPERATION PROCEDURES OF EQUIPMENT

SUB

PAR

T CC