mol safety standard specifications spill prevention 1 level gauge for oil storage tank 2 high level...

5
MOL Safety Standard Specifications

Upload: truongnguyet

Post on 25-May-2018

269 views

Category:

Documents


2 download

TRANSCRIPT

Page 1: MOL Safety Standard Specifications spill prevention 1 Level Gauge for Oil Storage Tank 2 High Level Alarm for Oil Storage Tank 3 High-High Level Alarm for Oil Storage Tank 4 Overflow

MOL SafetyStandard Specifications

Page 2: MOL Safety Standard Specifications spill prevention 1 Level Gauge for Oil Storage Tank 2 High Level Alarm for Oil Storage Tank 3 High-High Level Alarm for Oil Storage Tank 4 Overflow

Flame Retardant CurtainEliminates fire spreading in accommodation cabins

2

11

4

4

Security Cameras in Engine RoomHelps to find fire quickly and identify safety routes for evacuation and firefighting

FireProtection

FireProtection

Air control unit

Air SealEliminates oil leaks from PropellerShaft Stern tube

Oil spill prevention

Propeller Boss Cap Fins (PBCF)MOL original energy saving device– in use since 1987

Environment

6

3

5

High Expansion Foam Fire Extinguishing SystemReliable and much safer for crew than conventional CO2 system

FireProtection

PBCF

Oil tank unit

Flame retardant

MOL Safety Standard Specifications

Established in 2006 and has been under constant improvement ever since.From lessons learnt and experience of MOL.

Read about some of key safety features on our vessels!

When droppingthe chains

Overhead viewQuick release system

Normalcondition

Windlass Anchor chains

Outboard side seal

Seal ring

Air cell

Quick Release SystemFast detachment of anchor chains in emergency situations

Collisions and Groundings Prevention

7

Bunker OverflowPrevention SystemEliminates risk of fuel oil overflowing

Oil spill prevention

1 High Level Alarm

2 High-High Level Alarm

3 Overflow Alarm

4 Bunker Control Panel

Page 3: MOL Safety Standard Specifications spill prevention 1 Level Gauge for Oil Storage Tank 2 High Level Alarm for Oil Storage Tank 3 High-High Level Alarm for Oil Storage Tank 4 Overflow

★★

★★

Light Duty Type Fireman’s OutfitCan be speedily put on and allows free movement

FireProtection

Portable Rescue DavitRescues crew from enclosed spaces

Life saving

AED (Automated External Defibrillator)

Can save lives of those suffering heart attack

Life saving

Iridium satellite phone with wind-up chargerEnables emergency communicationunder no electric power situation

Life saving

Inflatable life jacketAllows free movement when working on deck, and prevents drowning

Life saving

Expansion

Easy to Move

Mitsui O.S.K. Lines, Ltd. | http://www.mol.co.jp/ | http://www.mol.co.jp/en/index.html

Page 4: MOL Safety Standard Specifications spill prevention 1 Level Gauge for Oil Storage Tank 2 High Level Alarm for Oil Storage Tank 3 High-High Level Alarm for Oil Storage Tank 4 Overflow

The "MOL Safety Standard Specifications" are unique to MOL and go beyond regulations set out in laws and international treaties, ensuring that MOL maintains a higher level of safety aboard its operated vessels. The specifications were first adopted in 2006 to draw upon the lessons of its earlier serious marine incidents, and are continually revised and updated based on its experiences.

The "MOL Safety Standard Specifications" currently comprise of total of 68 items as listed on this paper and highlighted items on the list are introduced on the brochure.

1 Fire Detectors in Various Locations 18 Oil Splash Prevention for Pipe Joint

2 Security Cameras in Engine Room 19 Arrangement of Electric Cable

3 Location of Fireman's Outfits 20 Material of Emergency Cable

4 Light Duty Type Fireman's Outfits 21 Oil Splash Prevention for Diesel Generator

5 High Expansion Foam Fire Extinguishing System 22 Fuel Valve Cooling System of Diesel Generator

6 Pump Capacity of Local Extinguishing System 23 Drain Pipe from Diesel Generator

7 Structure of Fire Dampers 24 Drain Alarm for Diesel Generator

8 Ready Function for CO2 Fire Extinguishing System 25 Position of Burner

9 Hydrant Connection in CO2 Bottle Room 26 Location of Main Switchboard

10 Special Design for Emergency Fire Pump 27 Arrangement of Oil Tank

11 Eye-plate inside Escape Trunk 28 Arrangement of Air Vent from Oil Tank

12 Door Lock with Internal Release 29 Capacity of Hydraulic Oil Tank

13 Compact and Lightweight Transceiver 30 Arrangement of Gas Bottle

14 Air Line for Quick Closing Valve 31 Oil Coaming for Machinery

15 Location of Purifier Room 32 Safety Function for Bow Thruster Panel

16 Location of Fire Control Station 33 Flame Retardant Curtain

17 Arrangement of Emergency Cable 34 Cabin Item for Fire Prevention

Fire Protection

Page 5: MOL Safety Standard Specifications spill prevention 1 Level Gauge for Oil Storage Tank 2 High Level Alarm for Oil Storage Tank 3 High-High Level Alarm for Oil Storage Tank 4 Overflow

Oil spill prevention

1 Level Gauge for Oil Storage Tank

2 High Level Alarm for Oil Storage Tank

3 High-High Level Alarm for Oil Storage Tank

4 Overflow Tank for Oil Storage Tank

5 Bunker Control Panel

6 Location of SOPEP Locker

7 Air Seal

8 Integrated Bilge Water Treatment System

9 Hydraulic Oil Piping

10 CCR Camera in Cargo Control Room

1 Quick Release System

2 Adjustable Chain Controller

3 Clear SWL Indication on Fittings

4 Brake System for Windlass & Winch

5 ECDIS Monitor in Captain Day Room

6 VHF Radio in Working Place

7 Two Day Light Signal

8 Anemometer and Anemoscope in Working Place

9 Reliable Steering System

10 Arrangement of Steering Gear System

11 Emergency Operation of Main Engine

12 Ballast Control Console

13 Prevention for Miss Ballast Operation

14 Alarm on Ballast Control Console

15 Fe-asy Checker 26

16 Location of Bilge Alarm

17 Bilge Alarm in Engine Room

18 Loading Calculator

19 DO Supply Pump of Diesel Generator

Collisions and Groundings Prevention

1 Inflatable Life Jacket

2 Portable Rescue Davit

3 Iridium Satellite Phone with Wind-up Charger

4 AED (Automated External Defibrillator)

Life saving

1 Propeller Boss Cap Fins (PBCF)

Environment