models smt /smt h/smt 130m/smt /smt d 150 · supply circuit. 4. to reduce the risk of injury to...

4
1. Make sure that the electric service supply voltage is AC 120V, 60Hz. 2. Follow all local electrical and safety codes, as well as the National Electrical Code (NEC) and the Occupational Safety and Health Act (OSH Act). 3. Always disconnect the power source before working on or near the ventilating fan, motor or junction box. 4. Protect the power cord from sharp edges, oil, grease, hot surfaces, chemicals or other objects. 5. Do not kink the power cord. 6. Do not install the unit where ducts are configured as shown in Fig. A. 7. Provide suction parts with proper ventilation. 8. This unit is UL listed for use over a bathtub or shower when installed in a GFCI-protected branch circuit. 9. These ventilating fans are intended for residential usage only. WARNING TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, OR INJURY TO PERSONS, OBSERVE THE FOLLOWING: 1. Use this unit only in the manner intended by the manufacturer. If you have questions, contact the manufacturer. 2. Before servicing or cleaning the unit, switch the power off at the service panel and lock the service disconnecting means to prevent the power from being switched on accidentally. When the service disconnecting means cannot be locked, securely fasten a prominent warning device, such as a tag, to the service panel. 3. Installation work and electrical wiring must be done by a qualified person(s) in accordance with all applicable codes and standards, including fire-rated construction. 4. Sufficient air is needed for proper combustion and exhausting of gases through the flue (chimney) of fuel burning equipment to prevent back drafting safety standards such as those published by the National Fire Protection Association (NFPA), and the American Society for Heating Refrigeration and Air Conditioning Engineers (ASHRAE) and local code authorities. 5. When cutting or drilling into the wall or ceiling, do not damage electrical wiring and other hidden utilities. 6. Ducted ventilating fans must always be vented to the outdoors. 7. If this unit is to be installed over a tub or shower, it must be marked as appropriate for the application and be connected to a GFCI (Ground Fault Circuit Interrupter) - protected branch circuit. 8. Do not use this unit with any other solid-state control device. Solid-state controls may cause harmonic distortion, which can cause a motor humming noise. 9. NEVER place a switch where it can be reached from a tub or shower. 10. Not to be installed in a ceiling thermally insulated to a value greater than R40. (This is required for installation in Canada only). Fig. A CAUTION 1. For general ventilating use only. Do not use to exhaust hazardous or explosive materials and vapors. 2. Not for use in cooking areas. (Fig. B) 3. This product must properly connect to the grounding conductor of the supply circuit. 4. To reduce the risk of injury to persons, install the fan at least 7 feet (2.1m) above the floor. Fig. B SUPPLIED ACCESSORIES Part name Appearance Quantity Grille For models of: SMT130, SMT130H, SMT150, SMT150D 1 For model of: SMT130M 1 Tapping Screw (ψ4x25) 5 Screw (#8-32x1/4”) 5 Duct connector 1 Suspension bracket I 13” (318.5mm) 2 Suspension bracket II 13” (318.5mm) 2 Turning angle too large Duct shrink Too many elbows Elbow near the body Body 45° Cooking area 45° Do not install above or inside this area Cooking Equipment floor VENTILATION FAN READ AND SAVE THESE INSTRUCTIONS GENERAL SAFETY INFORMATION INSTALLATION AND OPERATING INSTRUCTIONS follow the heating equipment manufacturer’s guideline and Page 1. MODELS SMT130/SMT130H/SMT130M/SMT150/SMT150D

Upload: others

Post on 12-Mar-2020

25 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: MODELS SMT /SMT H/SMT 130M/SMT /SMT D 150 · supply circuit. 4. To reduce the risk of injury to persons, install the fan at least 7 feet (2.1m) above the ˝oor. Fig. B SUPPLIED ACCESSORIES

1. Make sure that the electric service supply voltage is AC 120V, 60Hz.

2. Follow all local electrical and safety codes, as well as the National Electrical Code (NEC) and the Occupational Safety and Health Act (OSH Act).

3. Always disconnect the power source before working on or near the ventilating fan, motor or junction box.

4. Protect the power cord from sharp edges, oil, grease, hot surfaces, chemicals or other objects.

5. Do not kink the power cord.

6. Do not install the unit where ducts are con�gured as shown in Fig. A.

7. Provide suction parts with proper ventilation.

8. This unit is UL listed for use over a bathtub or shower when installed in a GFCI-protected branch circuit.

9. These ventilating fans are intended for residential usage only. WARNING

TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, OR INJURY TO PERSONS, OBSERVE THE FOLLOWING:

1. Use this unit only in the manner intended by the manufacturer. If you have questions, contact the manufacturer.

2. Before servicing or cleaning the unit, switch the power o� at the service panel and lock the service disconnecting means to prevent the power from being switched on accidentally. When the service disconnecting means cannot be locked, securely fasten a prominent warning device, such as a tag, to the service panel.

3. Installation work and electrical wiring must be done by a quali�ed person(s) in accordance with all applicable codes and standards, including �re-rated construction.

4. Su�cient air is needed for proper combustion and exhausting of gases through the �ue (chimney) of fuel burning equipment to prevent back draftingsafety standards such as those published by the National Fire Protection Association (NFPA), and the American Society for Heating Refrigeration and Air Conditioning Engineers (ASHRAE) and local code authorities.

5. When cutting or drilling into the wall or ceiling, do not damage electrical wiring and other hidden utilities.

6. Ducted ventilating fans must always be vented to the outdoors.

7. If this unit is to be installed over a tub or shower, it must be marked as appropriate for the application and be connected to a GFCI (Ground Fault Circuit Interrupter) - protected branch circuit.

8. Do not use this unit with any other solid-state control device. Solid-state controls may cause harmonic distortion, which can cause a motor humming noise.

9. NEVER place a switch where it can be reached from a tub or shower.

10. Not to be installed in a ceiling thermally insulated to a value greater than R40. (This is required for installation in Canada only).

Fig. A

CAUTION

1. For general ventilating use only. Do not use to exhaust hazardous or explosive materials and vapors.

2. Not for use in cooking areas. (Fig. B)

3. This product must properly connect to the grounding conductor of the supply circuit.

4. To reduce the risk of injury to persons, install the fan at least 7 feet (2.1m) above the �oor.

Fig. B SUPPLIED ACCESSORIES

Part name Appearance Quantity

Grille

For models of: SMT130, SMT130H, SMT150, SMT150D

1

For model of: SMT130M 1

Tapping Screw (ψ4x25) 5

Screw (#8-32x1/4”) 5

Duct connector

1

Suspension bracket I 13” (318.5mm)

2

Suspension bracket II 13” (318.5mm)

2

Turning angle too large Duct shrink

Too many elbows Elbow near the body

Body

45°

Cooking area

45°

Do not install above or inside this area

CookingEquipment �oor

VENTILATION FAN

READ AND SAVE THESE INSTRUCTIONS GENERAL SAFETY INFORMATION

INSTALLATION AND OPERATING INSTRUCTIONS

follow the heating equipment manufacturer’s guideline and

Page 1.MODELS SMT130/SMT130H/SMT130M/SMT150/SMT150D

Page 2: MODELS SMT /SMT H/SMT 130M/SMT /SMT D 150 · supply circuit. 4. To reduce the risk of injury to persons, install the fan at least 7 feet (2.1m) above the ˝oor. Fig. B SUPPLIED ACCESSORIES

INSTALLATION Attach duct connector Option 1. Attach the duct connector from outside and secure by using one screw (#8-32x1/4”). Insert tab into hole in housing

Screw from Parts Bag Option 2. Attach the duct connector from the housing can inside, and secure by using one screw (#8-32x1/4”).

Pull existing ductworkinto Housing

Screw fromParts Bag

Insert tab into hole inhousing

Install the housing (I)-using suspension brackets

1. Sliding suspension brackets available to allow for positioning of housing anywhere between joists up to a span of 24”.

2. Insert the suspension brackets into the channels on the housing. Make sure the tabs face up as shown. (Fig. C )

3. Extend the suspension brackets to the width of the joists. Hold the fan in place by wrapping the suspension bracket tabs around the bottom of the joist. Make sure the fan body is level and perpendicular to the joist. (Fig. D )

4. Ensure that the distance between the ceiling and fan body is appropriate for mounting the grille.

5. Secure the suspension brackets to the joists with nails or using the tapping screws (ψ4x25) through holes near nails.

6. Secure the suspension bracket to the fan body using the screws (8-32 x 1/4").

7. Follow steps 2 to 6 of the installation instructions to complete the installation work.

Channel

Suspension Bracket

Tab Face

Fig. C

Bottom of Joist

JoistJoist

Screw

Fig. D

Install the housing (II)-using mounting tabs

Slotted tabs are provided to position the housing �ush with 1/2” ceiling material. Bend the tabs outwards 90° (Use a screw driver if desired) and position the housing so that the tabs rest against the bottom edge of the joists (or front of the stud). Nail the housing to the joist or stud using four nails to ensure a solid, quiet installation. (Fig. E & F)

Joist

Tabs

Fig. E

Screw 4X25

Joist

Fig. F

Install the housing (III)-existing ceiling installation

Position the housing so that it is centered in the existing ceiling opening; make sure the housing is �ush with the �nished ceiling. Nail the housing in place and then drive the nails through the housing where indicated by arrows.(Fig. G)

Nails

Fig. G

Page 2.MODELS SMT130/SMT130H/SMT130M/SMT150/SMT150D

Page 3: MODELS SMT /SMT H/SMT 130M/SMT /SMT D 150 · supply circuit. 4. To reduce the risk of injury to persons, install the fan at least 7 feet (2.1m) above the ˝oor. Fig. B SUPPLIED ACCESSORIES

Page 3.MODELS SMT130/SMT130H/SMT130M/SMT150/SMT150D

Duct connection

Ceiling

Body

Tape

Duct

Outside

Gradient1°~2°

Inside

Fig. H

1. Insert the duct into the duct connector and tape all ductwork connections to make them secure and airtight. (Fig. H)

2. Install the duct with a gradient 1°~2° to the outside.

Connect wiring

1. Follow all local electrical and safety codes.

2. NEVER place a switch where it can be reached from a tub or shower.

3. Connect wires as shown in wiring diagrams.

Moti on Model: SMT130 M

Single Speed Model s: SMT130 , SMT150

OFF

ON L

NPOWER SWITCH

JUNCTION BOX SWITCH BOX

WHITE

BLACK

GREENG RD

BLACK

ON/OFF SWITCH(purchase separately) SWITCH BOX

120 VACLINE IN

WHITE

GROUND(bare)

POWERSWITCH

WIRINGPLATE

Humidity Model: SMT130H Dual Speed Model: SMT150D

HI

POWER SWITCH

MODE SWITCH

JUNCTION BOX SWITCH BOX

WHITE

BLACKOFF

ON

WHITE

BL UE

GREENGRD

L

N

L

N

ON/OFF SWITCH(purchase separately) SWITCH BOX

120 VACLINE IN

WIRINGPLATE

BLACKWHITEGROUND

(bare)

BLUE

MODESWITCH

POWERSWITCH

4. Using wire nuts (not provided), connect the house power cable to the

ventilating fan wires. 5. 14 AWG (2.1 mm2) is the smallest conductor that shall be used for

branch-circuit wiring. Grille attachment

1. Insert the motion sensor unit into the grille (Fig. I) (only for SMT130M)

2. Insert the mounting springs into the slots and mount the grille to the body. (Fig. J)

Sensor unit

Celling

Grille

Fig. I

Slots

Spring

Fig. J

Page 4: MODELS SMT /SMT H/SMT 130M/SMT /SMT D 150 · supply circuit. 4. To reduce the risk of injury to persons, install the fan at least 7 feet (2.1m) above the ˝oor. Fig. B SUPPLIED ACCESSORIES

Page 4.MODELS SMT130/SMT130H/SMT130M/SMT150/SMT150D

Operation

SMT130M SMT150DSMT130H

Low speed air volumepreset control (SMT130H,SMT130M, SMT150D).

Delay time control(SMT130M & SMT150D)or Humidity preset control(SMT130H).

control options control options control options

Single Models: SMT130, SMT150 1. Single speed control mode: Turn the POWER switch on to operate at

single speed mode - the LED indicator will be green.

Humidity Model: SMT130 H 2. Humidity control mode: Turn the POWER switch on to operate at

humidity control mode - the LED indicator will be blue. When the ambient humidity is higher than the user-adjustable set-point, the fan will run at full speed. When the ambient humidity is lower than the set-point, the fan will continue to run at the full speed until a 10-minute time delay has elapsed, and then will automatically change to the user-adjustable low speed air�ow.

3. Full speed mode: Turn the MODE switch on to operate at full speed mode - the LED indicator will be amber.

Factory setting: low speed air�ow 70CFM, humidity 60%RH. Note: Humidity tolerance is about ±10%.

Motion Model: SMT130 M 4. Motion control mode: Turn the POWER switch on to operate at motion

control mode. When motion is detected, the fan will run at full speed mode - the LED indicator will be amber. When motion is not detected, the fan will continue to run at the full speed until the user-adjustable time delay has elapsed, and then will automatically change to the user-adjustable low speed air�ow - the LED indicator will be green.

Factory setting: low speed air�ow 70CFM, time delay 15 minutes.

Dual Speed Model: SMT15 0D 5. Low speed control mode: Turn the POWER switch on (MODE switch is o�)

to operate at the user-adjustable low speed air�ow - the LED will be green.

6. Full speed control mode: Turn the POWER switch & MODE switch on to operate at full speed mode - the LED indicator will be amber. When the user turns the MODE switch o�, the fan will continue to run at the full speed until the user-adjustable time delay has elapsed, and then will automatically change to the user-adjustable low speed air�ow - the LED indicator will be green.

Factory setting: low speed air�ow 70CFM, time delay 15 minutes. MAINTENANCE WARNING:

Disconnect the power source before working on the unit. Routine maintenance must be done every year.

CAUTION: 1. Never use gasoline, benzene, thinner or any other such chemicals to

clean the ventilating fan.

2. Do not allow water to enter the motor.

CLEANING 1. Pull down the springs to remove the grille.

2. Wash and clean the grille. (Use non-abrasive kitchen detergent and wipe dry with a new cloth.)

3. Using a cloth dampened with non-abrasive kitchen detergent, remove any dirt from the ventilating fan. Wipe dry with a new cloth.

4. Replace the grille. DIMENSIONS

11.375"

(289)10.5"(267)

7.675"(195)

14"

(356)14"(356)

Unit: Inches(mm)

6"(150)

SPECIFICATIONS

Model No. Voltage

(V) Frequency

(Hz)

Power @ 0.1” SP

(W)

Air Flow @ 0.1” SP

(CFM)

Weight (lb.)

Power (W) Note

SMT130 120 60 11.6 130 10.4 28 Single Speed

SMT130 H 120 60 11.6 130 10.4 28 Humidity

Sensor

SMT130 M 120 60 11.6 130 10.4 28 Motion Sensor

SMT150 120 60 16.9 150 10.4 30 Single Speed

SMT150D 120 60 16.9 150 10.4 30 Dual

Speed Note: Design and speci�cations subject to change without notice.

WARRANTY

DELTA ELECTRONICS THREE YEAR LIMITED WARRANTY Delta Electronics Inc. (”Delta Electronics”) warrants to the original consumer purchaser in the

USA that the Breez ventilation fan products will be free from defects in material or workmanship. This warranty is limited to three (3) years from the original date of purchase. Limitations and Exclusions 1. During the warranty period, a replacement for any defective product will be supplied free of

charge for installation by the consumer. The warranty provided herein does not cover charges for labor or other costs incurred in the troubleshooting, repair, removal, and installation service.

2. All returns of defective parts or products must include the product model number, and must be made through an authorized Delta Electronics distributor. Authorized returns must be shipped prepaid. Repaired or replacement products will be shipped by Delta Electronics F.O.B. shipping point.

3. Delta Electronics shall not be liable for any indirect, incidental, consequential, punitive, or special damages arising out of or in connection with products use or performance, regardless of the form of action whether in contract, tort (including negligence), strict product liability or otherwise.

4. This warranty does not extend to �uorescent lamp starters and tubes. 5. The warranty does not cover if user does not comply with manufacturer’s installation manual. 6. To qualify for warranty service, you must notify Delta Electronics at the address or telephone

number below. 7. Delta Electronics shall have no liability to the original owner-user with respect to any defect

caused by abuse, misuse, neglect, improper transportation or storage, improper testing, improper installation, improper operation, improper use, improper maintenance, improper repair, improper alteration, improper modi�cation, tampering or accident of products or parts thereof, or unusual deterioration or degradation of products or parts thereof due to a physical environment beyond

Address: 4405 Cushing Parkway, Fremont, CA 94538 US Toll Free Number: 1 -888 -979 -9889

the requirements of products’ speci�cations.

3. Do not soak resin parts in water over 140°F (60°C).