models: hvr bi-level cooler hthbhvrbl-nf with bottle filler · 2012-10-15 · page 2 printed in the...

2
HYDROBOOST HVR Bi-Level Cooler with Bottle Filler HTHBHVR8BL-NF Complete water station including HydroBoost™ bottle filling station and HVR water cooler. HVR WATER COOLER HYDROBOOST™ BOTTLE FILLING STATION Stainless steel design for tamper-resistance. Pushbutton activation enhanced with embossed user graphics. Quick fill rate is 1.1 gallons per minute on chilled model and 1.5 gpm on ambient model. Laminar flow provides a clean fill with minimal splash and easy maintenance. 30-second shut-off timer for water flow. Recessed orifice to prevent GENERAL SUGGESTED SPECIFICATION halseytaylor.com HALSEY TAYLOR, 2222 CAMDEN COURT, OAK BROOK, ILLINOIS 60523 6-2012 JOB NAME: ______________________ ________________________________ ________________________________ ENGINEER/CONTRACTOR NAME: ________________________________ APPROVAL: _____________________ DATE: __________________________ Models: GREEN COUNTER™ Visually displays count of plastic water bottles saved from the landfills. INLET STRAINER Easily cleaned in-line strainer screen traps particles of 140 microns or larger before they enter the waterway. TEMPERATURE CONTROL Positive sensing thermostat for controlling temperature of storage tank water. Factory set at 50 o F adjustable + 5 o F. REFRIGERATION SYSTEM (Model HTHBHVR8BL-NF Only) Unit provides 8GPH of 50 o F drinking water at 90 o F ambient air and 80 o F inlet water. Hermetically sealed, positive start compressor with lifetime lubrication and built-in overload protection, efficient capillary sizing, large capacity dryer-strainer and self-lubricated fan cools copper/ aluminum condenser. R-134a refrigerant. Protected by Halsey Taylor’s Limited Warranty. Trap and service stop not included. NOTE: Continued product improvement makes specification sheets subject to change without notice. Vandal-Resistant cross-contamination. Protected behind tempered glass. Model HTHBHVR8BL-NF shall deliver 8GPH of 50 F drinking water at 90 F ambient air and 80 F inlet water. Model HTHBHVRBL-NF shall deliver non-chilled drinking water. Shall have stainless steel construction. Shall include vandal-resistant, one-piece bubbler with integral hood. Shall include vandal-resistant pushbutton activation with embossed user graphics. Shall include 30-second auto shut-off for water flow. Shall include Green Counter with tempered glass protective covering. Shall provide 1.1-1.5 gpm with laminar flow for minimal splash and recessed orifice to prevent cross-contamination. Cooler shall have stainless steel basin with anti-splash ridge and removeable drain strainer. Shall comply with ADA standards, UL399, CAN/CSA 22.2 No. 120, NSF/ANSI 61 and NSF/ANSI 372. o o o Self-contained, stainless steel, wall mount single level water cooler. Model HTHBHVR8BL-NF delivers chilled water; HTHBHVRBL-NF delivers ambient drinking water. Vandal-resistant one-piece, chrome- plated bubbler with integral hood guard design to prevent tampering, airborne deposits and contamination. Automatic stream height regula- tor is located inside unit to prevent tampering. A constant stream height is automatically maintained under line pressures that vary from 20 to 105 psi. Includes self-closing vandal-resistant pushbutton which does not require grasping or twisting. Type 300 series stainless steel cooler top with satin finish to resist stains and corrosion. Basin includes anti-splash ridge and contoured to insure proper drainage. HTHBHVRBL-NF

Upload: others

Post on 31-Mar-2020

2 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: Models: HVR Bi-Level Cooler HTHBHVRBL-NF with Bottle Filler · 2012-10-15 · Page 2 Printed in the U.S.A Bi-Level HVR Cooler with HydroBoost™ Bottle Filler (CONTINUED) HTHBHVR8BL-NF

HYDROBOOST™

HVR Bi-Level Cooler with Bottle Filler

HTHBHVR8BL-NF

Complete water station including HydroBoost™ bottle filling station and HVR water cooler.

HVR WATER COOLER

HYDROBOOST™ BOTTLE FILLING STATION Stainless steel design for tamper-resistance. Pushbutton activation enhanced with embossed user graphics. Quick fill rate is 1.1 gallonsper minute on chilled model and 1.5 gpm on ambient model. Laminar flow provides a clean fill with minimal splash and easy maintenance. 30-second shut-off timer for water flow. Recessed orifice to prevent

GENERAL

SUGGESTED SPECIFICATION

halseytaylor.com HALSEY TAYLOR, 2222 CAMDEN COURT, OAK BROOK, ILLINOIS 60523 6-2012

JOB NAME: ______________________

________________________________

________________________________

ENGINEER/CONTRACTOR NAME:

________________________________

APPROVAL: _____________________

DATE: __________________________

Models:

GREEN COUNTER™Visually displays count of plastic water bottles saved from the landfills.

INLET STRAINER Easily cleaned in-line strainer screen traps particles of 140 microns or larger before they enter the waterway.

TEMPERATURE CONTROLPositive sensing thermostat for controlling temperature of storage tank water. Factory set at 50o F adjustable + 5o F.

REFRIGERATION SYSTEM (Model HTHBHVR8BL-NF Only)Unit provides 8GPH of 50oF drinking water at 90oF ambient air and 80oF inlet water. Hermetically sealed, positive start compressor with lifetime lubrication and built-in overload protection, efficient capillary sizing, large capacity dryer-strainer and self-lubricated fan cools copper/ aluminum condenser. R-134a refrigerant. Protected by Halsey Taylor’s Limited Warranty.

Trap and service stop not included.

NOTE: Continued product improvement makes specification sheets subject to change without notice.

Vandal-Resistant

cross-contamination.

Protected behind tempered glass.

Model HTHBHVR8BL-NF shall deliver 8GPH of 50 F drinking water at 90 F ambient air and 80 F inlet water. Model HTHBHVRBL-NF shall deliver non-chilled drinking water. Shall have stainless steel construction. Shall include vandal-resistant, one-piece bubbler with integral hood. Shall include vandal-resistant pushbutton activation with embossed user graphics. Shall include 30-second auto shut-off for water flow. Shall include Green Counter with tempered glass protective covering. Shall provide 1.1-1.5 gpm with laminar flow for minimal splash and recessed orifice to prevent cross-contamination. Cooler shall have stainless steel basin with anti-splash ridge and removeable drain strainer. Shall comply with ADA standards, UL399, CAN/CSA 22.2 No. 120, NSF/ANSI 61 and NSF/ANSI 372.

ooo

Self-contained, stainless steel, wall mount single level water cooler. Model HTHBHVR8BL-NF delivers chilled water; HTHBHVRBL-NF delivers ambient drinking water. Vandal-resistant one-piece, chrome-plated bubbler with integral hood guard design to prevent tampering, airborne deposits and contamination. Automatic stream height regula-tor is located inside unit to prevent tampering. A constant stream height is automatically maintained under line pressures that vary from 20 to 105 psi. Includes self-closing vandal-resistant pushbutton which does not require grasping or twisting. Type 300 series stainless steel cooler top with satin finish to resist stains and corrosion. Basin includes anti-splash ridge and contoured to insure proper drainage.

HTHBHVRBL-NF

Page 2: Models: HVR Bi-Level Cooler HTHBHVRBL-NF with Bottle Filler · 2012-10-15 · Page 2 Printed in the U.S.A Bi-Level HVR Cooler with HydroBoost™ Bottle Filler (CONTINUED) HTHBHVR8BL-NF

Printed in the U.S.APage 2

Bi-Level HVR Cooler with HydroBoost™ Bottle Filler (CONTINUED)

HTHBHVR8BL-NF and HTHBHVRBL-NF

OPERATING PRESSURESSupply water – 105 psi maximum Minimum 40 psi supply line pressure required in special circumstances when both units are in use simultaneously to ensure adequate flow.

ELECTRICALHydroBoost Station equipped with plug-in, 3-wire ground type service cord. Install 120-volt receptacle, rated at 15-amp minimum, to receive 3-wire parallel blade grounding type male plug.

CL

CL

13-7/8"352mm

18-3/4"476mm

20-1/8"511mm

25-1/8"638mm

5"127mm

2-7/16"63mm

10"254mm

20-3/8"518mm

37-1/2"952mm 2-9/16"

65mm

7-1/4"185mm

6-1/2"165mm

11/16"18mm

4-9/16"116mm

O 5/16"8mm HOLES

(5 PL)

FINISHED FLOOR

F

AE

D

B

F

E

C

6-3/4"171mm

12-5/16"313mm

33-1/16"840mm

ORIFICEHEIGHT

39-9/16"1005mmORIFICEHEIGHT

HANGERBRACKET

1/4" X 1/2" (6mm X 13mm)OBROUND HOLE (5 PL)

27"686mm*

48"1219mm

2-5/8"67mm

18-9/16"472mm

5-1/8"131mm

4-1/8"105mm

51-1/8"1298mm

31-15/16"811mm

RIM HEIGHT

8"203mm

18-1/16"459mm

7"178mm

7"178mm

1-1/4"32mm

1-1/4"32mm

16-5/16"414mm

O 5/16"8mm HOLES

(3 PL)5-3/4"146mm

5-3/4"146mm

1-3/8"35mm1-3/8"

35mm

18-1/2"470mm

3-1/2"89mm4-1/2"114mm

6-1/4"159mm

* REDUCE HEIGHT BY 3” FOR INSTALLATION OF CHILDRENS ADA COOLERLEGEND:A = RECOMMENDED WATER SUPPLY LOCATION 3/8” O.D. UNPLATED COPPER TUBE CONNECT STUB 1-1/2” (38mm) OUT FROM WALL. SHUT OFF VALVE NOT FURNISHED.B = RECOMMENDED LOCATION FOR WASTE OUTLET 1-1/4” O.D. DRAIN.C = 1-1/2” TRAP NOT FURNISHED.D = ELECTRICAL SUPPLY (3) WIRE RECESSED BOX, DUPLEX OUTLET REQUIRED.E = INSURE PROPER VENTILATION BY MAINTAINING 6” (152mm) MIN. CLEARANCE FROM CABINET LOUVER TO WALL.F = 7/16” BOLT HOLES FOR FASTENING UNITS TO WALL.