model: - edgeedge.rit.edu/edge/p13632/public/documents/specifications... · web viewmass flow...

14
Micromotion Flow tubes ($2000-$3000 new) ELITE Model Nominal Line Size Maximum Flow Rate Flow Rate at 1 Bar rP (water) English Units Metric Units English Units Metric Units English Units Metric Units CMF010 1/10 to 1/6 inch 2 to 4 mm 4 lb/min 108 kg/h 3.4 lb/min 92 kg/h CMF025 1/4 to 1/2 inch 6 to 13 mm 80 lb/min 2180 kg/h 48 lb/min 1,306 kg/h BRIEF SPECIFICATIONS Mass flow accuracy +/-0.05% of flow rate Volume flow accuracy +/-0.05% of flow rate Gas flow accuracy +/-0.35% of flow rate Density accuracy +/-0.0002 g/cc Wetted parts 304L, 316L Stainless Steel, C22 Nickel Alloy or Super Duplex Temperature rating -400 to 662°F (-240 to 350°C) Pressure rating 1450 - 6000** psi (100 to 413** bar) * Listed specifications may vary with sensor or transmitter model. **Available on select line sizes Micromotion Transmitter ($3000-$4000 new) BRIEF SPECIFICATIONS Flow accuracy with ELITE sensors with F-Series sensors with D, DT, DL sensors +/- 0.10% of flow rate +/- 0.20% of flow rate

Upload: trantruc

Post on 20-May-2018

234 views

Category:

Documents


1 download

TRANSCRIPT

Page 1: Model: - EDGEedge.rit.edu/edge/P13632/public/Documents/Specifications... · Web viewMass flow accuracy +/-0.05% of flow rate Volume flow accuracy +/-0.05% of flow rate Gas flow accuracy

Micromotion Flow tubes ($2000-$3000 new)

ELITE Model

Nominal Line Size Maximum Flow Rate Flow Rate at 1 Bar rP (water)

English Units Metric Units English Units Metric Units English Units Metric Units

CMF010 1/10 to 1/6 inch 2 to 4 mm 4 lb/min 108 kg/h 3.4 lb/min 92 kg/h

CMF025 1/4 to 1/2 inch 6 to 13 mm 80 lb/min 2180 kg/h 48 lb/min 1,306 kg/h

BRIEF SPECIFICATIONS

Mass flow accuracy +/-0.05% of flow rate

Volume  flow accuracy +/-0.05% of flow rate

Gas flow accuracy +/-0.35% of flow rate

Density accuracy +/-0.0002 g/cc

Wetted parts 304L, 316L Stainless Steel, C22 Nickel Alloy or Super Duplex

Temperature rating -400 to 662°F (-240 to 350°C)

Pressure rating 1450 - 6000** psi (100 to 413** bar)* Listed specifications may vary with sensor or transmitter model.**Available on select line sizes

Micromotion Transmitter ($3000-$4000 new)

 BRIEF SPECIFICATIONSFlow accuracy

with ELITE sensors

with F-Series sensors

with D, DT, DL sensors

+/- 0.10% of flow rate

+/- 0.20% of flow rate

+/- 0.15% of flow rate

Density Accuracy

+/- 0.0005 g/cc

Page 2: Model: - EDGEedge.rit.edu/edge/P13632/public/Documents/Specifications... · Web viewMass flow accuracy +/-0.05% of flow rate Volume flow accuracy +/-0.05% of flow rate Gas flow accuracy

with ELITE sensors

with F-Series sensors

with D, DT, DL sensors

+/- 0.002 g/cc

Varies by sensor model

Outputs

2 analog (milliampere) outputs

1 frequency/pulse output

1 dual-channel frequency output*

1 optocoupler output*

1 control output

Local display**

Digital Communication

Bell-202 and/or RS-485 serial standards

HART and/or Modbus protocols

Power Supply Options

85-250 VAC

110/115 VAC*

220/230 VAC*

12-30 VDC*Rack-mount version only.**Optional on field-mount version. Standard on rack-mount version.

Micropump ($300-$400 new)

Page 3: Model: - EDGEedge.rit.edu/edge/P13632/public/Documents/Specifications... · Web viewMass flow accuracy +/-0.05% of flow rate Volume flow accuracy +/-0.05% of flow rate Gas flow accuracy
Page 4: Model: - EDGEedge.rit.edu/edge/P13632/public/Documents/Specifications... · Web viewMass flow accuracy +/-0.05% of flow rate Volume flow accuracy +/-0.05% of flow rate Gas flow accuracy
Page 5: Model: - EDGEedge.rit.edu/edge/P13632/public/Documents/Specifications... · Web viewMass flow accuracy +/-0.05% of flow rate Volume flow accuracy +/-0.05% of flow rate Gas flow accuracy

Rockwell Flex Drive (around $700 new)

Link in case the chart is not readable: http://literature.rockwellautomation.com/idc/groups/literature/documents/td/22-td001_-en-p.pdf

Page 6: Model: - EDGEedge.rit.edu/edge/P13632/public/Documents/Specifications... · Web viewMass flow accuracy +/-0.05% of flow rate Volume flow accuracy +/-0.05% of flow rate Gas flow accuracy

Reliance Motor ($410 new)

Page 7: Model: - EDGEedge.rit.edu/edge/P13632/public/Documents/Specifications... · Web viewMass flow accuracy +/-0.05% of flow rate Volume flow accuracy +/-0.05% of flow rate Gas flow accuracy

Honeywell Controller (model DC300C-0-000-20-0000-0) EZ Price (ea.): $499.00

Specifications

Attached in PDF file in email

Page 8: Model: - EDGEedge.rit.edu/edge/P13632/public/Documents/Specifications... · Web viewMass flow accuracy +/-0.05% of flow rate Volume flow accuracy +/-0.05% of flow rate Gas flow accuracy

Intellifaucet taken from http://www.hassmfg.com/ifvif.plSince not sure of specific 375 modelFeatures and flow are the biggest differences between Intellifaucet models. Here's a quick summary of the features of the 3 series of Intellifaucet mixing valves:

D & E Series - low-cost, 15 presets - suitable for general purpose use and in photographic darkrooms

K & RK Series - 1/10 degree settings, digital display - used in the most demanding laboratory, commercial and industrial environments

BC Series - batching - very popular in pretzel, bagel, cracker and bread bakeries

Flow capacity is the next most important factor for selecting an Intellifaucet. The maximum flow rates range from 4 GPM to 42 GPM. The following table summarizes the key features of the different Intellifaucet models.

Intellifaucet Comparison TableFeature D & E K & RK BC

Price range $545 - $765 $1,095 - $3,895 $1,570 - $3,895Flow Range Brass Models* GPM

250 1/4 - 5375 1 - 10

250 1/4 - 4.2375 1 - 10500 2 - 23750 5 - 42

250 1/4 - 4.2375 1 - 10500 2 - 23750 5 - 42

Flow Range SS Models* GPM

NA 250 1/4 - 4.2375 1 - 8.5500 2 - 15750 5 - 42

250 1/4 - 4.2375 1 - 8.5500 2 - 15750 5 - 42

Batch Volume for 1 minute draw*

NA NA 250 14 lbs375 70 lbs500 150 lbs750 300 lbs

Controls 16 position rotary knob

Membrane keypad Membrane keypad

Remote inputs NA K NARK 4-20mA temp, dry contact Start/Stop

4-20mA temp, dry contact Start Batch/Stop, pulse input from flowmeter

Outputs Power LED, Temp Ready LED

Digital Display Digital Display, 9VDC for flowmeter Hall effect sensor

*The fine print: Flow rates and batch volumes are approximate. Factors such as supply pressure, flow restrictions, piping configuration, added components, filters and screens all affect these numbers. These numbers are shown for comparison purposes only. All valves fail in place during power failure. Use a UPS backup system for critical applications.

Page 9: Model: - EDGEedge.rit.edu/edge/P13632/public/Documents/Specifications... · Web viewMass flow accuracy +/-0.05% of flow rate Volume flow accuracy +/-0.05% of flow rate Gas flow accuracy

Variations of 375

E375 http://www.hassmfg.com/search.pl/1213638750-2927?keyword=1278

Specifications

Flow range at 50 psi: 1 - 10 GPMFlow adjustment: none (must use external valve)Valve port size: 3/8 inchValve Cv: 1.7Inlet size: 1/2 NPT male on 4 inch centersOutlet size: 1/2 NPT femaleValve body material: Brass with Type 303ss seatValve trim materials: Type 303 stainless steelInlet pressure: 10 - 100 psiInlet temperature: 35 - 180 °F (1.7 - 82.2 °C)Power requirements: 12 - 16 VDC (AC power adaptor included)(International Power Supplies available at extra cost - specify voltage and frequency)Power consumption: 23 Watts maximumControl accuracy: ± 0.2 °F (0.1 °C)Step response time: less than 2 secondsControl temperature range: 55 - 115 °F (12.8 - 46.1 °C)Operating EnvironmentTemperature range: 40 - 140 °F (4.4 - 60 °C)Humidity range: 10 - 90 % relative humidityStandards: Exceeds ASSE Standard 1016

Preset Temperatures°F: COLD, 55, 60, 65, 70, 75, 80, 85, 90, 95, 100, 105, 110, 115, HOT°C: COLD, 12.8, 15.6, 18.3, 21.1, 23.9, 26.7, 29.4, 32.2, 35.0, 37.8, 40.6, 43.3, 46.1, HOT

K375http://www.hassmfg.com/search.pl/1213638750-2927?keyword=1009

Specifications

Flow range at 50 psi: 1 to 10 GPMFlow adjustment: keypad selectable from 15 - 100 % of capacityValve port size: 3/8 inchValve Cv: 1.4Inlet size: 1/2 NPT male on 4 inch centersOutlet size: 1/2 NPT femaleValve body material: Brass with Type 303 stainless steel seatValve trim materials: Type 303 stainless steel

Page 10: Model: - EDGEedge.rit.edu/edge/P13632/public/Documents/Specifications... · Web viewMass flow accuracy +/-0.05% of flow rate Volume flow accuracy +/-0.05% of flow rate Gas flow accuracy

Control accuracy: +/- 0.2 F (0.1 C)Step response time: less than 4 secondsTemperature setting increment: 0.1 (F or C)Flow setting increment: 1 per centControl temperature range: 40 - 140 F (4.4 - 60 C)Timer range: 1 - 240 minutesInlet pressure: 10 - 100 psiInlet temperature: 35 - 180 F (1.7 - 82.2 C)Power requirements: 12 - 16 Volts DC (AC Power Adaptor included)(International Power Supplies available - specify voltage and frequency)Power consumption: 23 Watts maximumEnvironment temperature range: 40 - 140 F (4.4 - 60 C)Environment humidity range: 10 - 90 % relative humidityStandards: Exceeds ASSE Standard 1016

RK375 http://www.hassmfg.com/search.pl/1213638750-2927?keyword=1015

Specifications

Flow range at 50 psi: 1.0 - 10.0 GPMFlow adjustment: keypad selectable from 15 - 100 % of capacityValve port size: 3/8 inchValve Cv: 1.4Inlet size: 1/2 NPT male on 4 inch centersOutlet size: 1/2 NPT femaleValve body material: Brass with Type 303 stainless steel seatValve trim materials: Type 303 stainless steelControl accuracy: +/- 0.2 F (0.1 C)Step response time: less than 4 secondsTemperature setting increment: 0.1 (F or C)Flow setting increment: 1 per centControl temperature range: 40 - 140 F (4.4 - 60 C)Timer range: 1 - 240 minutesRemote input: 4-20 mA current loopRemote input impedence: 250 OhmsRemote switch requirement: dry contact closure, 5 VDC, 10 mA, 20 mS minimum contactInlet pressure: 10 - 100 psiInlet temperature: 35 - 180 F (1.7 - 82.2 C)Power requirements: 12 - 16 Volts DC (AC Power Adaptor included)(International Power Supplies available - specify voltage and frequency)Power consumption: 23 Watts maximumEnvironment temperature range: 40 - 140 F (4.4 - 60 C)Environment humidity range: 10 - 90 % relative humidityStandards: Exceeds ASSE Standard 1016

Page 11: Model: - EDGEedge.rit.edu/edge/P13632/public/Documents/Specifications... · Web viewMass flow accuracy +/-0.05% of flow rate Volume flow accuracy +/-0.05% of flow rate Gas flow accuracy

Bauman Control Valves (32-24-588, ½ inch, Cv 0.5 and 1.0)

NOTE: I found this on EBAY and it was the only information I could find for a ½” valve that was close to the model number

http://www.ebay.com/itm/HD-Baumann-1-2-Control-Valve-Model-32-246885-/330672132765?pt=LH_DefaultDomain_0&hash=item4cfd98529d

Model: 32-246885

- Signal 4-20 MA- Size 1/2"- Supply 25 PSI- Body Rating 300- Body 31655- Bench Range 5-15 PSI

Also found on EBAY, the correct model number but 1 inch and with a different Cv than provided

http://www.ebay.com/itm/Fisher-Baumann-32-24-588sf-588-sd-control-valve-actuator-/271054683803?pt=LH_DefaultDomain_0&hash=item3f1c1e3e9b

Model: 32-24-588SF

3-10 PSIBody rating: 150Size: 1”CV:9.5