model 3b76 accessories & options - oapl · dummies, alignment axis, attachment hardware and...
TRANSCRIPT
![Page 1: Model 3B76 Accessories & Options - OAPL · dummies, alignment axis, attachment hardware and wrenches. Product Data Sheet Small Adult Ankle Joint ( 16mm Systems ) The Small Adult Triple](https://reader033.vdocuments.mx/reader033/viewer/2022042808/5f83613b2b5bc67b4d3d3713/html5/thumbnails/1.jpg)
3B76-LATL
3B76-LATR
3B76-MEDL
3B76-MEDR
Small Adult Triple Actionwith Left Lateral Stirrup
Small Adult Triple Actionwith Right Lateral Stirrup
Small Adult Triple Actionwith Left Medial Stirrup
Small Adult Triple Actionwith Right Medial Stirrup
Each
Each
Each
Each
Order No. Description UOM
Patent Pending©2019 Becker Orthopedic Appliance Co., All rights reserved.Revision 4/1/19
800-521-2192 | 248-588-7480 800-923-2537 | 248-588-2960
BeckerOrthopedic.com
pf
Model 3B76Small Adult Triple Action® ankle joint
Alignment Scale
Front View Side View
Standard(blue)
No Yes Yes Yes Yes
Standard(blue)
X1(low)
X2 (low/mod)
X3(mod)
X4(high)
X5(very high)
Booster Required
Bottom Spring
Top Spring
Stiffness
10° 10° 10° 10° 10°Max. ROM
High (silver)Standard
(blue)Standard
(blue)High
(silver)High
(silver)None
Standard(blue)
Standard(blue)
PIN Guide
1 2 3 4 5Spring Configuration
Accessories & Options
3B00-BS Small Adult Triple ActionBooster Spring Only Each
Order No. Description UOM
Booster Spring with multiple resist options
Model 3B00-BS
Lateral StirrupModels 3B76-LATR
& 3B76-LATL
Medial StirrupModels 3B76-MEDR
& 3B76-MEDL
FabricationTool Kit
Models 3B00-FTK
The fabrication tool kit includes fabrication dummies, alignment axis, attachment hardware and wrenches.
Product Data Sheet
Small Adult Ankle Joint( 16mm Systems )
![Page 2: Model 3B76 Accessories & Options - OAPL · dummies, alignment axis, attachment hardware and wrenches. Product Data Sheet Small Adult Ankle Joint ( 16mm Systems ) The Small Adult Triple](https://reader033.vdocuments.mx/reader033/viewer/2022042808/5f83613b2b5bc67b4d3d3713/html5/thumbnails/2.jpg)
The Small Adult Triple Action ankle joint for 16mm systems is designed to provide highly adjustable active ankle control of the lower extremity during all phases of the gait cycle. The component excels in the orthotic treatment of complex disorders, such as stroke, multiple sclerosis and cerebral palsy.
Ankle alignment, plantarflexion / dorsiflexion spring stiffness and range of motion are independently adjustable to help simplify optimization. The clinician can easily tune the component to meet the changing needs of their patient through all stages of recovery and rehabilitation.
The Triple Action ankle joint provides multiple spring options, high spring stiffness and spring durability. The booster spring offers five high stiffness spring options with a direct reading range of motion dial. Ankle alignment is read directly from the component body to simplify adjustment and track patient progress.
± 10°
Spring 1 standard resistance
With the adjustment screw, or Booster Spring turned
fully clockwise, the 0° ROM setting locks the stirrup
ComponentSetting
AdjustmentRange Reference
0-10° ROM adjustment range
•
• 5° per turn of the adjustment screw or Booster Spring
5 high stiffness spring options (No. 1 thru 5)
Ankle Alignment
Plantarflexion / Dorsiflexion Spring Stiffness
(with optional BoosterSpring, Model 3B00-BS)
Plantarflexion / Dorsiflexion Spring Stiffness
(Model 3B76)
Plantarflexion / Dorsiflexion Range of Motion
0° alignment corresponds to the corrected angle of the
cast during fabrication
Standard spring stiffness x1/x2/x3/x4/x5 depending on Booster Spring configuration
Standard spring stiffness suitable for flaccid equinus in patients up to 80 Kg (180 lb)
Specifications
Features IndicationsLower limb functional and structural deficits as a result of:
ContraindicationsPatient weight greater than 80 kg (180 lb)
Independent adjustment of:
Five high stiffness spring options (with optional Booster Spring)
High mediolateral stability and smooth articulation in single upright orthotic designs
Peroneal nerve palsyStrokeMultiple sclerosisCerebral palsyMyelomeningoceleContractureSurgical release or tendon transferOther pathologic neuromusculoskeletal conditions
••••••••
Ankle alignmentPlantarflexion/dorsiflexion range of motionPlantarflexion/dorsiflexion spring stiffness
•••
Description
Patent Pending©2019 Becker Orthopedic Appliance Co., All rights reserved.Revision 4/1/19
800-521-2192 | 248-588-7480 800-923-2537 | 248-588-2960
BeckerOrthopedic.com
pf
Dimensions(3B76)
165mm(6.5in)
89mm(3.5in)
16mm(0.63in)
Product Data Sheet
Small Adult Ankle Joint( 16mm Systems )