miroslav karásek pavel peterka jan radil 1o ge long-haul transmissions without in-line edfas
TRANSCRIPT
Miroslav KarásekPavel Peterka
Jan Radil
1O GE long-haul transmissions without in-line EDFAs
7 February , 2005 ONDM 2005, Milano, Italy 2
1O GE long-haul transmissions without in-line EDFAs
Outline
Motivation
Experimental results
Conclusions
7 February , 2005 ONDM 2005, Milano, Italy 3
Utilization of dark fibres – CEF networks
Cost effective deployment of multigigabit lines (N x 1 GE, N x 10 GE) using inexpensive commercial equipment (NRZ, without FEC)
National Research and Educational Networks (NRENs) rely on leased dark fibres and prefer to have no active components between the transmitter and the receiver
Due to the commercial availability of high-power erbium-doped fibre amplifiers, the span of repeaterless links has substantially increased
Repeaterless or Nothing-in-line (NIL) approach
1O GE long-haul transmissions without in-line EDFAs
Motivation
7 February , 2005 ONDM 2005, Milano, Italy 4
1O GE long-haul transmissions without in-line EDFAs Motivation
Fibre distances
For CzechLight - experimental and breakable network
7 February , 2005 ONDM 2005, Milano, Italy 5
Results of error-free transmission of 2 x 10 GE plus 2 x 1 GE channels over 200 km and 2 x 10 GE over 250 km of G.652 fibre without deployment of in-line amplifiers
1 x 10 GE and 2 x 10 GE over 287 km of mixed G.652/G.655 link
Commercially available equipment (Cisco Catalyst 6503 with 10 GE blades, high power and low noise Keopsys EDFAs and Raman fibre lasers) have been used in our experimental set-up
All the active components and the DCF were placed either at the transmitter, or at the receiver side of the link
BER better then 10-12 (using either the PING utility, or by BERT Acterna ONT-50)
1O GE long-haul transmissions without in-line EDFAs
Experimental results
7 February , 2005 ONDM 2005, Milano, Italy 6
1O GE long-haul transmissions without in-line EDFAs Experimental results – 4 WDM channels over 200
km
7 February , 2005 ONDM 2005, Milano, Italy 7
1O GE long-haul transmissions without in-line EDFAs
Experimental results – 4 WDM channels over 200 km
optical power at the input port of EDFA1
(resolution bandwidth of the optical spectrum analyzer 0.033 nm)
7 February , 2005 ONDM 2005, Milano, Italy 8
1O GE long-haul transmissions without in-line EDFAs
Experimental results – 4 WDM channels over 200 km
Optical power at the input to EDFA2: PSSMF=20 dBm
7 February , 2005 ONDM 2005, Milano, Italy 9
1O GE long-haul transmissions without in-line EDFAs
Experimental results – 4 WDM channels over 200 km
Optical powers at
the output of DCF
7 February , 2005 ONDM 2005, Milano, Italy 10
1O GE long-haul transmissions without in-line EDFAs
Experimental results – 4 WDM channels over 200 kmdependence of BER on EDFA1 output power for the 10 GE channel at 1545.97 nmmeasured by the ACTERNA ONT-50
7 February , 2005 ONDM 2005, Milano, Italy 11
1O GE long-haul transmissions without in-line EDFAs
Experimental results – 2 WDM channels over 250 km
λ1=1544.98nm, λ2=1545.97nm
7 February , 2005 ONDM 2005, Milano, Italy 12
1O GE long-haul transmissions without in-line EDFAs
Experimental results – 2 WDM channels over 250 km
Optical power at the output of the DCF2 in case of post-compensation scheme: PSSMF=15.5 dBm, PRL=1.1 W
7 February , 2005 ONDM 2005, Milano, Italy 13
1O GE long-haul transmissions without in-line EDFAs Experimental results – 2 channels / 287 km
G.652/G.655
287 km set-up not tested properly with BERT
7 February , 2005 ONDM 2005, Milano, Italy 14
1O GE long-haul transmissions without in-line EDFAs Experimental results – 2 channels / 287 km
The eye diagram – before the receiver
7 February , 2005 ONDM 2005, Milano, Italy 15
1O GE long-haul transmissions without in-line EDFAs Experimental results – 2 channels / 287 km
Number of successfully received packets as a function of PEDFA1
7 February , 2005 ONDM 2005, Milano, Italy 16
1O GE long-haul transmissions without in-line EDFAs Experimental results – 2 channels / 287 km
Number of successfully received packets as a function of PRL
7 February , 2005 ONDM 2005, Milano, Italy 17
Using commercially available and relatively cheap optical communication systems and components, NIL error-free transmission of N x 1 GE and N x 10 GE channels is possible
The error-free transmission is not very sensitive to optical powers launched into the SSMF and DCF, neither to Raman pump power
These results are encouraging especially for operators of national research and educational networks who rely on leased dark fibres and prefer as long NIL transmission as possible
We expect better results using DWDM transmitters (GBIC, SFP, XENPAK, XFP)
1O GE long-haul transmissions without in-line EDFAs
Conclusions
7 February , 2005 ONDM 2005, Milano, Italy 18
1O GE long-haul transmissions without in-line EDFAs References
[1] Karásek, M. - Peterka, P. - Radil, J. , „202 km repeaterless transmission of 2 x 10 GE plus 2 x 1 GE channels over standard single mode fibre. “, In: Optics Communications 235, pp. 269-274., 2004.
[2] Karásek, M. - Peterka, P. - Radil, J. , „Repeaterless Transmission of 2 x 10 GE Channels over 252 km of Standard Single Mode Fibre without in-line EDFA. “, In: IEE Proc. Optoelectronics, sent for publication, 2004.
[3] Radil, J. - Karásek, M., „Experiments with 10 GE long-haul transmissions in academic and research networks.“, In: I2 member meeting, Arlington, VA, 2004.
[4] Radil, J., „ Experiments on optical layer and breakable research networks. “, In: 14th TF-NGN meeting, Amsterdam, 2004.
7 February , 2005 ONDM 2005, Milano, Italy 19
1O GE long-haul transmissions without in-line EDFAs Thank you for your attention!