milk sampler product data - icar · 2017-12-05 · milk sampler product data introduction the milk...

18
Milk sampler Product data Introduction The Milk sampler is designed to be used with the Voluntary Milking System. Typically, the sampler is connected to the Milking Sta- tion once a month to obtain samples. Con- nections are made to the FloMaster milk me- ter, the pneumatic system and the Alcom bus. The Alcom bus enables data communi- cation with the Milking Station. Surplus milk is returned to the station. The sampler can handle many different kinds of bottles just by changing the sample holder. In addition, the transparent main cover enables monitoring of the sampling process. To simplify maintenance and service, the control box is opened with a slide latch. MEMO V3 3VMX_4190_070_en_752 (0207) 4190:070:1(4) Milk sampler VMX Product data Main cover Control box Slide latch Connection to the FloMaster milk meter on the Milking Station. Connection to the Milking Station's Alcom bus. Connection to the Milking Station's pneumatic system. Return of surplus milk to the Milking Station.

Upload: others

Post on 28-May-2020

4 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: Milk sampler Product data - ICAR · 2017-12-05 · Milk sampler Product data Introduction The Milk sampler is designed to be used with the Voluntary Milking System. Typically, the

Milk sampler

Product data

IntroductionThe Milk sampler is designed to be usedwith the Voluntary Milking System. Typically,the sampler is connected to the Milking Sta-tion once a month to obtain samples. Con-nections are made to the FloMaster milk me-ter, the pneumatic system and the Alcombus. The Alcom bus enables data communi-cation with the Milking Station. Surplus milkis returned to the station.

The sampler can handle many differentkinds of bottles just by changing the sampleholder. In addition, the transparent maincover enables monitoring of the samplingprocess.

To simplify maintenance and service, thecontrol box is opened with a slide latch.

MEMO V3

3VMX_4190_070_en_752 (0207) 4190:070:1(4)

Milk sampler

VMX Product data

Main cover

Control box

Slidelatch

Connection to the FloMaster milkmeter on the Milking Station.

Connection to the Milking Station'sAlcom bus.

Connection to the Milking Station'spneumatic system.

Return of surplus milk to theMilking Station.

Page 2: Milk sampler Product data - ICAR · 2017-12-05 · Milk sampler Product data Introduction The Milk sampler is designed to be used with the Voluntary Milking System. Typically, the

MEMO V3

3VMX_4190_070_en_752 (0207) 4190:070:2(4)

Milk sampler

VMX Product data

Steppingmotors

Milk container

Pneumatictube-clamp valve

Connection to FloMaster

Note: It is of utmost importance that the cylindri-cal cones on the milk container and the con-tainer lid are facing each other and that they areproperly inserted in the clamp when assembled.

Return valve

Sample valve

Runner (at zeroposition)

Page 3: Milk sampler Product data - ICAR · 2017-12-05 · Milk sampler Product data Introduction The Milk sampler is designed to be used with the Voluntary Milking System. Typically, the

Function and handling

Zero point calibrationAt start-up, the stepping motors move therunner to the zero point. The runner holdsthe flexible tube that conveys milk to thesample bottles. The positions of the samplebottles are calculated using the zero point asreference.

PositioningWhen a cow is starting to be milked, the run-ner is moved to a designated sample bottle.At the same time, the pneumatic tube-clampvalve opens the inlet to the milk container toallow passage of milk from the FloMastermilk meter. There is vacuum in the containerat this point.

SamplingOnce the milking is complete, the samplevalve is opened 5 times to admit air into thecontainer and thereby mixing the milk. Theinlet valve then closes and the container ispressurised; the return valve is opened andsurplus milk is returned to the Milking Sta-tion. The return valve closes and pressuris-ation stops. The container is then pressur-ised again and the sample valve is openedto convey the remaining milk to the samplebottle.

CleaningThe Milk sampler can be cleaned at thesame as the Milking Station, provided that itis connected to the station. The cleaning wa-ter takes the same route as the milk. Therunner is positioned at the zero point andwater is drained through a duct at the bot-tom of the Milk sampler.

TransportationWhen the Milk sampler is transported be-tween different locations, the runner must bepositioned at the zero point.

MEMO V3

3VMX_4190_070_en_752 (0207) 4190:070:3(4)

Milk sampler

VMX Product data

Page 4: Milk sampler Product data - ICAR · 2017-12-05 · Milk sampler Product data Introduction The Milk sampler is designed to be used with the Voluntary Milking System. Typically, the

Technical dataMax air overpressure 8 bar.

Min air overpressure 6 bar.

Max air pressure after the pressure regula-tor: 0.8 bar.

Min air pressure after the pressure regulator:0.6 bar.

Max voltage 24 VDC.

Max power consumption:

Milk valves 8 W/ valve.

Control valves 2.5 W/valve.

Weight 20 kg.

MEMO V3

3VMX_4190_070_en_752 (0207) 4190:070:4(4)

Milk sampler

VMX Product data

Page 5: Milk sampler Product data - ICAR · 2017-12-05 · Milk sampler Product data Introduction The Milk sampler is designed to be used with the Voluntary Milking System. Typically, the

Milk sampler

Operation

Connecting the Milk sampler1. Stop the cow traffic through the Milking

Station. Milking must not take place whensteps 1 to 10 below are carried out.

2. Remove the cover on the milking moduleand place the sampler in front of the sta-tion.

3. Shut off the vacuum by turning the man-ual valve on the sanitary trap.

4. Remove the plug from the FloMaster milkmeter.

5. Insert the inlet into the milk meter.It might be necessary to check this con-nection for air leakages once the sam-pling has started.

6. Connect the sampler tube by sliding theconnector over holder on the milk meter.Use the hook to secure the position. Seefigure 6 on the next page.

7. Connect the pneumatic hose to the socketplaced above the FF meters. See figure 7below.

8. Connect the electrical cable to the Alcombus. See figure 8 below.

9. Connect the return line to the Milking Sta-tion. See figure 9 below.

Note: For proper operation, the return linemust be arranged as in figure 9.

10. Turn on the vacuum again.

MEMO V3

3VMX_4190_150_en_752 (0207) 4190:150:1(14)

Milk sampler

VMX Operation

Page 6: Milk sampler Product data - ICAR · 2017-12-05 · Milk sampler Product data Introduction The Milk sampler is designed to be used with the Voluntary Milking System. Typically, the

MEMO V3

3VMX_4190_150_en_752 (0207) 4190:150:2(14)

Milk sampler

VMX Operation

Slide the milk sampler connectorover the holder on the FloMaster.

Use the hook to secure the milksampler connection to theFloMaster.

Page 7: Milk sampler Product data - ICAR · 2017-12-05 · Milk sampler Product data Introduction The Milk sampler is designed to be used with the Voluntary Milking System. Typically, the

MEMO V3

3VMX_4190_150_en_752 (0207) 4190:150:3(14)

Milk sampler

VMX Operation

Connect the pneumatic hose to the socketabove the FF meters

Connect the electric cable to the Alcom bus.

Page 8: Milk sampler Product data - ICAR · 2017-12-05 · Milk sampler Product data Introduction The Milk sampler is designed to be used with the Voluntary Milking System. Typically, the

MEMO V3

3VMX_4190_150_en_752 (0207) 4190:150:4(14)

Milk sampler

VMX Operation

Connect the return line to the pipe on the end unit

The return line must be arranged as shownin the figure above; let it pass under the lockstrap and press it over the pipe end.

Page 9: Milk sampler Product data - ICAR · 2017-12-05 · Milk sampler Product data Introduction The Milk sampler is designed to be used with the Voluntary Milking System. Typically, the

SamplingA sampling sequence is normally performedduring a 24-hour interval and stopped after asystem cleaning. In this way, the samplerwill be cleaned after the sampling.

Note: The sampler must be disconnect be-fore milking starts again to avoid milk resi-dues in the sampler during storage or trans-portation

If milking has started anew, a system clean-ing should be performed again before themilk sampler is disconnected.

If this is inconvenient or impractical, carryout the steps under “Manual cleaning” belowin this chapter.

Starting a sampling sequenceSampling is performed by using the touchscreen.

– Press VMS in the top right corner to dis-play the VMS menu.

– Press Milk Sampler to display the Milksampler window.

– Select a sample bottle by typing the bot-tle's number in the Milk sampler window.Number one is normally used as the firstbottle.Use the Clear button if you type the wrongnumber.

– Press Start Sampling Milk at pos to startthe sampling.

Printed reports from sampling sequencesare available by using VMS Status. A reportcontains such items as the date of the sam-pling, cow numbers and milk yields.

For further information, see VMS Status,Program Description.

MEMO V3

3VMX_4190_150_en_752 (0207) 4190:150:5(14)

Milk sampler

VMX Operation

Displays the Milk sampler window.

The Milk sampler window.

VMS menu

Page 10: Milk sampler Product data - ICAR · 2017-12-05 · Milk sampler Product data Introduction The Milk sampler is designed to be used with the Voluntary Milking System. Typically, the

Stopping a sampling sequenceA sampling sequence is stopped manuallyfrom the touch screen.

– After the system cleaning, press Stop MilkSampling on the Milk sampler window.The runner then goes to the zero point.

– When the runner is at the zero point, dis-connect the Milk sampler from the MilkingStation.

– Remove the sample holder and flush theinside of the Milk sampler. Make sure thatthe runner is clean.

MEMO V3

3VMX_4190_150_en_752 (0207) 4190:150:6(14)

Milk sampler

VMX Operation

The Milk sampler window.

Page 11: Milk sampler Product data - ICAR · 2017-12-05 · Milk sampler Product data Introduction The Milk sampler is designed to be used with the Voluntary Milking System. Typically, the

Adjustments

Pressure regulator– Connect a manometer after the pressure

regulator.

– Start the sampling from the touch screen.

– Fold the drain tube to close it.

– Adjust the pressure to 0.7 bar.

– Tighten the locking nut.

Tube wheel– Turn the tube wheel 8 rounds clockwise.

– Pull the tube through the hole in the wheel.

– Let the wheel pull back the tube.

– Check that 250 mm of the tube protrudesfrom the hole in the wheel.

MEMO V3

3VMX_4190_150_en_752 (0207) 4190:150:7(14)

Milk sampler

VMX Operation

Pressure regulator(attached to thecontrol-box cover).

Tube wheel

Page 12: Milk sampler Product data - ICAR · 2017-12-05 · Milk sampler Product data Introduction The Milk sampler is designed to be used with the Voluntary Milking System. Typically, the

Maintenance

Daily check– Clean the Milk sampler on the inside and

on the outside. Make sure that the step-ping motor screws and the guides areclean.

– Check the silicone tubes for damage.

Service– Exchange the silicone tubes every sixth

month.

– Lubricate the packing boxes every sixthmonth.

– Exchange the gasket in the milk containerevery sixth month.

– Check the pressure regulator every sixthmonth.

MEMO V3

3VMX_4190_150_en_752 (0207) 4190:150:8(14)

Milk sampler

VMX Operation

Page 13: Milk sampler Product data - ICAR · 2017-12-05 · Milk sampler Product data Introduction The Milk sampler is designed to be used with the Voluntary Milking System. Typically, the

Manual cleaningCarry out the steps below if there is risk ofremaining milk residues inside the sampler.This might be the case if the sampler wasnot disconneted immediately after a systemcleaning.

– Open the control-box cover and the maincover.

– Remove all hoses connected to the milkcontainer, then remove the container.

– Put one finger on the tube wheel to pre-vent it from unwinding too rapidly andthereby damaging the spring in the tubewheel. See figure 1.

– Lift up the sample tube that are inserted inthe runner. See figure 2.

– Remove the plastic silicon tube, comingfrom the tube wheel, from the metal tube.See figure 3.

Continued on the next page.

MEMO V3

3VMX_4190_150_en_752 (0207) 4190:150:9(14)

Milk sampler

VMX Operation

Sampletube

Page 14: Milk sampler Product data - ICAR · 2017-12-05 · Milk sampler Product data Introduction The Milk sampler is designed to be used with the Voluntary Milking System. Typically, the

Continued from the previous page.

– Retract the tube and unwind it slowly fromthe tube wheel by turning the wheel with afinger. See figure 4.

Note: Use a finger to control the speed ofthe tube wheel when unwinding the tube. Ifyou let the tube wheel rotate freely, thespring will be damaged and must be re-placed.

– Remove all tubes that have been into con-tact with milk. See figure 5.

– Clean the container and all tubes thathave been in contact with milk, using ap-propriate detergents.

Note: If the Milk Sampler has not beencleaned for a long time, the milk residuesmight be impossible to remove. In this case,replace the tubes.

Note: When re-assembling the milk con-tainer, make sure that the cylindrical coneson the container and the lid are positioned inaccordance with the figure below.

MEMO V3

3VMX_4190_150_en_752 (0207) 4190:150:10(14)

Milk sampler

VMX Operation

Disconnect thesetubes when cleaningthe Milk Samplermanually

Note that the cylindricalcones must be facingeach other and properlyinserted in the clampwhen re-assembling themilk container.

Clip

Cylindrical coneon container lid

Cylindrical cone onmilk container

Page 15: Milk sampler Product data - ICAR · 2017-12-05 · Milk sampler Product data Introduction The Milk sampler is designed to be used with the Voluntary Milking System. Typically, the

Milk diagram

VA 804 Milk Sample Inlet Valve

VL 801 Milk Sample Valve

VL 802 Milk Sample Return Valve

MEMO V3

3VMX_4190_150_en_752 (0207) 4190:150:11(14)

Milk sampler

VMX Operation

Inlet

Samplebottle

Milk container

Return line forsurplus milk

VA 804

B0,B1

VL 801 VL 802

R1 B2B3

C1

VL 802

VL 801

C1

Page 16: Milk sampler Product data - ICAR · 2017-12-05 · Milk sampler Product data Introduction The Milk sampler is designed to be used with the Voluntary Milking System. Typically, the

Pneumatic diagram

VA 803 Milk Sample Pressure Valve

VA 804 Milk Sample Inlet Valve

R1 Pressure Regulator

B3 To Alcom I/O board

B4 To Alcom I/O board

C1 Inlet Valve

MEMO V3

3VMX_4190_150_en_752 (0207) 4190:150:12(14)

Milk sampler

VMX Operation

Milkcontainer

VA 803

VA 804

R1B3

B4

C1

R1

VA 803 VA 804

Alcom I/O board

Page 17: Milk sampler Product data - ICAR · 2017-12-05 · Milk sampler Product data Introduction The Milk sampler is designed to be used with the Voluntary Milking System. Typically, the

MEMO V3

3VMX_4190_150_en_752 (0207) 4190:150:13(14)

Milk sampler

VMX Operation

88

VL802

VA

804

VA

803

Ye

Gy

5

Ysensor

Xsensor

VL801

3 2 1

+ S G

W181

21

W183

Bk

Bk

Bk

Bk

Bk

Bk

21

W182

Bk

Bk

Bk

Bk

21

32

1

+S

G

32

1

+S

G

32

1

+S

G

32

1

+S

G

32

1

+S

G

3 2 1

+ S G

3 2 1

+ S G

3 2 1

+ S G

3 2 1

+ S G

3 2 1

+ S G

3 2 1

+ S G

3 2 1

+ S G

321

+SG

321

+SG

321

+SG

321

+SG

321

+SG

321

+SG

321

+SG321

+SG

12

12

Ye Bn

Gr

Wh

Gy

Be

Rd

Bk

Ye

Gy

Be

Rd

Bk

X1

4321

Bn

Be

Bn

Be

Bn

Be

Bn

Be

21

Gy

Wh

Gr

Bn

Ye

1 2 3 4 5

Be

Rd

Gr

Ye/W

h

Bk

Y

R2

Be

Bk

Bn

R1

Be

Bk

Bn

Gy

Wh

Gr

Bn

Ye

1 2 3 4 5

Be

Rd

Gr

Ye/W

h

Bk

X

Gy

Wh

Gr

Bn

Ye

B 3 B 4

A0

A1

A2

A3

A4

B 0 B 1 B 2 B 5 B 6 B 7

C7 C5 C4 C3 C2 C1 C0C6

X3

X2

W188

W187

W186

W185

W184

W180

Milk

Sam

ple

Valv

e

Milk

Sam

ple

Retu

rnV

alv

e

Milk

Sam

ple

Pre

ssure

Valv

e

Milk

Sam

ple

Inle

tV

alv

e

Milk

sam

pler

Alc

omI/O

Page 18: Milk sampler Product data - ICAR · 2017-12-05 · Milk sampler Product data Introduction The Milk sampler is designed to be used with the Voluntary Milking System. Typically, the

MEMO V3

3VMX_4190_150_en_752 (0207) 4190:150:14(14)

Milk sampler

VMX Operation