microwave site master™ s820e “ site master: proven accuracy and reliability you can trust ”...

20
Microwave Site Master™ S820E Site Master: Proven Accuracy and Reliability you can trustSlide 1

Upload: william-foster

Post on 17-Dec-2015

220 views

Category:

Documents


1 download

TRANSCRIPT

Page 1: Microwave Site Master™ S820E “ Site Master: Proven Accuracy and Reliability you can trust ” Slide 1

Microwave Site Master™ S820E

“Site Master: Proven Accuracy and Reliability

you can trust”

Slide 1

Page 2: Microwave Site Master™ S820E “ Site Master: Proven Accuracy and Reliability you can trust ” Slide 1

Advanced Architecture

World’s first 40 GHz handheld cable &

antenna analyzer = widest frequency

coverage

Highest Dynamic Range 110 dB typical

Highest corrected directivity = highest

measurement accuracy

The most built-in Waveguide calibration

support, 10 bands standard + 4 custom

Full 4 receiver VNA architecture

Will support full reversing S-Parameter

measurements (Future VNA Option)

1 Hz frequency resolution across full range

of operation, even up to 40 GHz

Slide 2

1 MHz to 8, 14, 20, 30, 40 GHz Cable and Antenna Analyzer

Highest RF Immunity (+17 dBm)

250 x 177 x 61 mm (10.0 x 7.1 x 2.4 in)

<3.0 kg (6.6 lbs)

Page 3: Microwave Site Master™ S820E “ Site Master: Proven Accuracy and Reliability you can trust ” Slide 1

Advanced Architecture

Uses same sampler technology as our

premium VectorStar™ VNA models

Instant On from standby mode

Highest RF Immunity +17 dBm

650 us/point measurement speed typical

New efficient circuitry delivers >4 hour

battery life

Rugged K(m) connectors on units 20 GHz

and above. Easily convert to N(f) type

without compromising field ruggedness

Measure long, embedded transmission

systems easily with USB Transmission

Sensor and USB Extenders

Slide 3

Ruggedized K(m) test ports

easily and robustly converted to N(f)

using 71693-R adapters

stands up to rugged field use

Page 4: Microwave Site Master™ S820E “ Site Master: Proven Accuracy and Reliability you can trust ” Slide 1

Easy to use (Integrated Help)

Integrated Help function

System Info Tab displays instrument info,

hardware info and software info in one

convenient screen

FAQ Tab displays multiple frequently

asked questions. Touch any of the desired

questions to reveal the answer. Some FAQ

answers may include hyperlinks to the

built-in User Guide for more detailed

information

User Guide Tab provides easy access to

the instrument’s full HTML based user

guide. No longer need to carry a hardcopy

with you in the field

Slide 4

Help screen illustrating

multiple help selection tabs

Page 5: Microwave Site Master™ S820E “ Site Master: Proven Accuracy and Reliability you can trust ” Slide 1

Easy to use (Easy Guided Calibration)

Easy Guided Calibration

4 step Cal Setup allows you to select

from a variety of calibration types,

choose the calibration type that best

suits your needs

Choose between Coaxial or Waveguide

line type and following calibration

steps will change accordingly

Select the DUT connector type, photos

provide examples of what each

connector typically looks like

Once DUT connector type is selected,

the selection of built-in calibration kits

is narrowed down to models that fit

the chosen DUT type

Slide 5

S820E Guided Calibration simplifies

calibration process, minimizes errors

Page 6: Microwave Site Master™ S820E “ Site Master: Proven Accuracy and Reliability you can trust ” Slide 1

Easy to use (S820D-like Classic Mode)

S820D-like Classic Mode

Mimics the same basic GUI operation as

the former S810D/S820D models

Supports 2-Port Cable Loss like the

S8X0D series but uses extendable USB

sensors instead of basic diode detectors

1-port measurements like the S8X0D

models, no Smith Chart, no 1-port phase

measurement helps to minimize

confusion and reduce errors with new

users

Switch to Advanced Mode when

comfortable to gain access to more

measurement types and more

performance enhancing user control

features like adjustable IFBWSlide 6

820D-like Classic Mode GUI

Similar flow of operation compared

to previous S8X0D models

Page 7: Microwave Site Master™ S820E “ Site Master: Proven Accuracy and Reliability you can trust ” Slide 1

Easy to use (All connectors conveniently located on top)

All connectors located on top

Allows instrument to be used while in

protective softcase

No need to spend time looking for desired

connector

Keeps sides clear for easy handling

Reduces risk of cabling getting caught or

snagged on nearby items

Slide 7

1. RF Port 1 6. DC Power Input

2. RF Port 2 7. Two USB 2.0 Type A ports

3. BNC External Trigger Input 8. Ethernet Port 10/100 MB/s

4. BNC External Reference Input 9. 3.5 mm Aux Headphone

Jack Output5. USB Type Mini B

Page 8: Microwave Site Master™ S820E “ Site Master: Proven Accuracy and Reliability you can trust ” Slide 1

Versatile features and options (Advanced Mode)

Advanced Mode (Default)

Additional measurement types like Smith

Chart, 1-Port Phase, Transmission (2 port)

Transmission (Ext. Sensor)

Dual Display Format

Mix any 2 measurement types

Simultaneously measure RL/VSWR and 2-

Port Cable loss using external sensor

Supports different calibration types for

each display, EG:Upper trace has

standard 1-port OSL calibration, lower

trace has 2-Port external sensor

transmission calibration

Slide 8

820E Advanced Mode

Dual Display

Page 9: Microwave Site Master™ S820E “ Site Master: Proven Accuracy and Reliability you can trust ” Slide 1

Versatile features and options (Advanced Mode Continued)

System Function Tool Bar

Provides one-touch access to common

system functions like Preset, Save, Help,

Screenshot, Mode Selector, Full Screen

User Defined Shortcuts

Quick one-touch access to six favorite

user defined shortcuts. Recall favorite

setups without having to open Menu

screen or File menu

Additional Markers (8 vs 6) and additional

marker functions

Slide 9

820E Advanced Mode

System Function Tool Bar

And User Defined Shortcuts

Page 10: Microwave Site Master™ S820E “ Site Master: Proven Accuracy and Reliability you can trust ” Slide 1

Versatile features and options (High Accuracy Power Meter)

Measure True RMS power accurately using

Anritsu MA series USB power sensors

As low as ±0.16 dB uncertainty

Supports Inline High Power Measurements with

MA24105A

Easily configure upper/lower measurement

limits and scale

Displays both dBm and Watts simultaneously

Choose which one you prefer as the main

readout

Easily add offsets to correct for external

loss/gain

Easily set relative measurements

Slide 10

820E-High Accuracy Power Meter

Page 11: Microwave Site Master™ S820E “ Site Master: Proven Accuracy and Reliability you can trust ” Slide 1

Versatile features and options (Standard Features)

3 Year Warranty (1 year on battery)

2-Port Transmission Measurements

2-Port Cable Loss Measurement

(requires external USB Sensor)

High Accuracy Power Meter (requires

external USB Sensor)

Ethernet 10/100 port

Remote Control/PC File Transfer

3 USB ports (2 Type A, 1 Type mini-B)

Remote Control/PC File transfer

Peripheral device support

Large Internal Memory

Internally store >2000 files

Sweeps, setups, screenshotsSlide 11

820E-0720 includes two

71693-R ruggedized adapters

as standard accessories

Page 12: Microwave Site Master™ S820E “ Site Master: Proven Accuracy and Reliability you can trust ” Slide 1

Versatile features and options (Standard Features)

Built-in GPS support (requires 2000-1723-R)

10 user selectable languages

Fast preview of stored sweeps

Large 800 x 600 8.4” Easy to read High

Resolution TFT Touchscreen

Supports Daylight & Nighttime modes

Touch screen provides efficient GUI and

ease of use, with or without gloves

Alphanumeric keyboard

EZ Name Quick Matrix for fast saving

Can lock touch screen and use cursor

mode or USB mouse for instrument

control

Slide 12

820E-0720 includes two

71693-R ruggedized adapters

as standard accessories

Page 13: Microwave Site Master™ S820E “ Site Master: Proven Accuracy and Reliability you can trust ” Slide 1

Versatile features and options (Standard Features)

Active Thermal Management

Allows for faster warmup

Provides superior measurement stability

Passes stringent MIL-PRF-28800F Section

4.5.6.3 Explosive Atmosphere

Requirement

Increases MTBF and reliability

Hi Capacity Li-Ion field replaceable battery

Extend field operating time by adding a

spare optional battery

Hot swappable when externally powered

S820E-0720 model comes standard with two

71693-R ruggedized K(f) to N(f) adapters

Slide 13

820E-0720 includes two

71693-R ruggedized adapters

as standard accessories

Page 14: Microwave Site Master™ S820E “ Site Master: Proven Accuracy and Reliability you can trust ” Slide 1

Versatile features and options (Standard Features)

easyTest™ Tools

Generate and share measurement script

files among multiple users

Display images, work instructions, details

Allows multiple users to achieve

consistent results with reduced errors

Saves valuable time in the field

Line Sweep Tools (LST) Software

Edit sweeps, rename, archive

Generate PDF or HTML reports

Convert RL/VSWR to DTF

Convert RL/VSWR to Smith Chart

Slide 14

820E-0720 includes two

71693-R ruggedized adapters

as standard accessories

Page 15: Microwave Site Master™ S820E “ Site Master: Proven Accuracy and Reliability you can trust ” Slide 1

New accessories supporting S820E (New calibration kits)

New series of high performance coaxial

calibration OSL/TOSL kits

Specified across full instrument operating

temperature range: -10°C to +55°C. This

is an industry leading first

Newly developed and manufactured by

Anritsu, not 3rd party OEM like most

competitor’s offerings

Provides unbeatable performance up to

40 GHz.

K type (2.92mm) mechanically compatible

with SMA and 3.5mm connectors

1-year recommended calibration cycle

Slide 15

OSLX50A-XX, TOSLX50A-XX

High performance, full temperature

Coaxial Calibration Kits

Page 16: Microwave Site Master™ S820E “ Site Master: Proven Accuracy and Reliability you can trust ” Slide 1

New accessories supporting S820E (New calibration kits)

New series of high performance coaxial

calibration OSL/TOSL kits

Male and Female Models with through

component have equal electrical length

Each calibration kit comes with its own

soft case pouch, and includes hardcopy of

technical data sheet

Cal coefficients are built into S820E

firmware, just select the model and the

analyzer takes care of the rest

Other Anritsu hand held analyzers will

support new calibration kits via future

firmware updates

Slide 16

OSLX50A-XX, TOSLX50A-XX

High performance, full temperature

Coaxial Calibration Kits

Page 17: Microwave Site Master™ S820E “ Site Master: Proven Accuracy and Reliability you can trust ” Slide 1

New accessories supporting S820E (New Flexible Cables)

New series of 40 GHz high performance phase-

stable test port extension cables

Available with Ruggedized K(f) connectors

to mate securely to S820E test ports

Available with standard K type connectors

Can be used with Anritsu bench top VNA’s

like VectorStar™ and Lightning™

Provides best performance/price ratio

Highly flexible for easy connection and

usage

Available in 0.6m and 1.0m lengths

Slide 17

14 Series Phase-Stable Flexible Cables

Page 18: Microwave Site Master™ S820E “ Site Master: Proven Accuracy and Reliability you can trust ” Slide 1

New accessories supporting S820E (USB Transmission Sensor)

New SC8268 USB Transmission Sensor

Designed to optimize 2-Port cable loss

measurement/2-Port Transmission (Ext.

Sensor) measurement

Provides full coverage from 1 MHz to 40

GHz

Delivers most accurate results with lowest

uncertainty

Slide 18

SC8268 USB Transmission Sensor

Page 19: Microwave Site Master™ S820E “ Site Master: Proven Accuracy and Reliability you can trust ” Slide 1

New accessories supporting S820E (USB Extender + Cat 5e)

New 2000-1717-R USB Extender

Extends USB Sensor up to 85m for

measuring 2-Port cable loss on embedded

cables, or on any DUT with ends located

physically far from each other

Completely passive, requires no

additional power source

Use with standard Cat 5e cable available

everywhere (Cat 6 recommended for best

results)

Use with 2100-28-R Cat 5e cable to

extend up to 22.5m or purchase custom

length from local cable supplier

Slide 19

S820E shown with 2000-1717-R USB

Extender and 2100-28-R cable and

SC8268 USB Transmission Sensor

Page 20: Microwave Site Master™ S820E “ Site Master: Proven Accuracy and Reliability you can trust ” Slide 1

Microwave Site Master™ S820E Cable/Antenna Analyzer

Slide 20

Advanced architecture, Easy to use, Versatile features and options

“Site Master: Proven Accuracy and Reliability you can trust”