Redundancy
Jeffrey Lam RCDD
![Page 2: Microsoft power point 6. redundancy](https://reader036.vdocuments.mx/reader036/viewer/2022073117/55778ebad8b42acf398b50be/html5/thumbnails/2.jpg)
Different Tiers of data centers
![Page 3: Microsoft power point 6. redundancy](https://reader036.vdocuments.mx/reader036/viewer/2022073117/55778ebad8b42acf398b50be/html5/thumbnails/3.jpg)
HDA
EDA
ZDA
Redundancy
Manhole
MDA
ER
MDA
ER
Manhole
HDAHDA HDA
EDA EDA EDA
ZDA
TIER 1
TIER 2
TIER 3
TIER 4
LEGEND
![Page 4: Microsoft power point 6. redundancy](https://reader036.vdocuments.mx/reader036/viewer/2022073117/55778ebad8b42acf398b50be/html5/thumbnails/4.jpg)
99.995%DO WE REALLY NEED SUCH
HIGH AVAILABILTY???
If systems are up… Then yearly downtime is...
99.671% 1 day, 4 hours, 49 minutes
99.741% 23 hours, 41 minutes
99.982% 1 hour, 34 minutes
99.995% 26 minutes
CONSIDER THIS...
![Page 5: Microsoft power point 6. redundancy](https://reader036.vdocuments.mx/reader036/viewer/2022073117/55778ebad8b42acf398b50be/html5/thumbnails/5.jpg)
Redundancy
Normal
OperationN
100kVA
100kVA
N200kVA
Data Center
with
200kVA
power
requirement
1 UPS of 200kVA
capacity
2 UPS of 100kVA
capacity
A data center requires 200kVA of UPS power.
Which is the preferred design?
Are there any redundancy?
QUIZ
#1
![Page 6: Microsoft power point 6. redundancy](https://reader036.vdocuments.mx/reader036/viewer/2022073117/55778ebad8b42acf398b50be/html5/thumbnails/6.jpg)
Redundancy
100kVA
100kVA
100kVA
100kVA
100kVA
100kVA
100kVA
100kVA
100kVA
100kVA
100kVA
100kVA
100kVA
100kVA
100kVA
Redundant UPS systems delivering 200kVA power.
N
N+1
2N200kVA
power
required at
datacenter
Data Center
2(N+1)
![Page 7: Microsoft power point 6. redundancy](https://reader036.vdocuments.mx/reader036/viewer/2022073117/55778ebad8b42acf398b50be/html5/thumbnails/7.jpg)
Redundancy
100kVA
100kVA
100kVA
100kVA
100kVA
100kVA
100kVA
100kVA
100kVA
100kVA
100kVA
100kVA
100kVA
100kVA
100kVA
Component failure
Power failure
Normal Operation
Normal Operation
Normal Operation
Data Center
N
N+1
2N
2(N+1)
![Page 8: Microsoft power point 6. redundancy](https://reader036.vdocuments.mx/reader036/viewer/2022073117/55778ebad8b42acf398b50be/html5/thumbnails/8.jpg)
Redundancy
100kVA
100kVA
100kVA
100kVA
100kVA
100kVA
100kVA
100kVA
100kVA
100kVA
100kVA
100kVA
100kVA
100kVA
100kVA
Path failure
Power failure
Power failure
Normal Operation
Normal Operation
N
N+1
2N
2(N+1)
Data Center
![Page 9: Microsoft power point 6. redundancy](https://reader036.vdocuments.mx/reader036/viewer/2022073117/55778ebad8b42acf398b50be/html5/thumbnails/9.jpg)
Redundancy
100kVA
100kVA
100kVA
100kVA
100kVA
100kVA
100kVA
100kVA
100kVA
100kVA
DUAL FAILURE = components & path failure
Power Failure
Normal
Operation
2N
2(N+1)
Data Center
![Page 10: Microsoft power point 6. redundancy](https://reader036.vdocuments.mx/reader036/viewer/2022073117/55778ebad8b42acf398b50be/html5/thumbnails/10.jpg)
Redundancy
100kVA
100kVA
100kVA
100kVA
100kVA
100kVA
Data Center
QUIZ
#2
2(N+1)