microsenzorii stocastici ca noi instrumente de masurare a ...uefiscdi.gov.ro/userfiles/file/pn...

27
Microsenzorii stocastici ca noi instrumente de masurare a substantelor de importanta biologica PN-II-ID-PCE-2011-3-0570 Raluca-Ioana van Staden Laboratorul de Electrochimie si PATLAB Bucuresti Institutul National de Cercetare pentru Electrochimie si Materie Condensata PATLAB

Upload: others

Post on 23-Aug-2021

2 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: Microsenzorii stocastici ca noi instrumente de masurare a ...uefiscdi.gov.ro/userfiles/file/PN II_PCE_Competitia 2011...Microsenzorii stocastici ca noi instrumente de masurare a substantelor

Microsenzorii stocastici ca noi

instrumente de masurare a

substantelor de importanta biologica

PN-II-ID-PCE-2011-3-0570

Raluca-Ioana van Staden

Laboratorul de Electrochimie si PATLAB Bucuresti

Institutul National de Cercetare pentru Electrochimie si Materie Condensata

PATLAB

Page 2: Microsenzorii stocastici ca noi instrumente de masurare a ...uefiscdi.gov.ro/userfiles/file/PN II_PCE_Competitia 2011...Microsenzorii stocastici ca noi instrumente de masurare a substantelor

Obiective PATLAB

O1 Identificarea celor mai bune materiale nanostructurate pentru designul microsenzorilor stocastici; O2 Evaluarea diferitilor parametrii care pot afecta caracteristicilor de raspuns ale microsenzorilor stocastici cum ar fi, natura matricei, pH-ul si taria ionica, electrolitii; O3 Aplicarea noilor microsenzori stocastici la determinarea moleculelor de importanta biologica, cum ar fi hormoni tiroidieni, biomarkeri pentru obezitate, etc.; O4 Dezvoltarea de instrumente pentru scanarea substantelor de importanta biologica; O5 Dezvoltarea unei baze de date pentru analiza calitativa utilizand microsenzori stocastici; O6 Integrarea tinerilor cercetatori in echipa laboratorului.

Page 3: Microsenzorii stocastici ca noi instrumente de masurare a ...uefiscdi.gov.ro/userfiles/file/PN II_PCE_Competitia 2011...Microsenzorii stocastici ca noi instrumente de masurare a substantelor

Test de scanare pentru obezitate

PATLAB

Page 4: Microsenzorii stocastici ca noi instrumente de masurare a ...uefiscdi.gov.ro/userfiles/file/PN II_PCE_Competitia 2011...Microsenzorii stocastici ca noi instrumente de masurare a substantelor

Electroactive

material

Matrix Calibration

equation

Linear

conc.

range

toff

(s)

Sensitivity (mg/s . mL)

P DP 1/ton=0.02 + 1.96 x 102 x c

R = 0.9965 0.125pg/mL-0.125µg/mL 6.4 1.96x105

MD DP 1/ton=0.06 + 1.69 x 102 x c

R = 0.9966 1.25pg/mL-0.125µg/mL 3.9 1.69x105

MD Graphite

1/ton=0.04 + 1.30 x 102 x c

R = 0.9791 1.25pg/mL-0.125µg/mL 5.2 1.30x105

MD Graphene

1/ton=0.03 + 2.26 x 103 x c

R = 0.9993 0.125pg/mL-12.5pg/mL 6.1 2.26x106

MD CNT 1/ton=0.05 + 0.07 x 102 x c

R = 0.9091 12.5pg/mL-1.25µg/mL 3.9 7.00x103

MD C60

1/ton=0.02 + 1.21 x 102 x c

R = 0.9998 1.25pg/mL-0.125µg/mL 7.4 1.21x105

Leptin PATLAB

Page 5: Microsenzorii stocastici ca noi instrumente de masurare a ...uefiscdi.gov.ro/userfiles/file/PN II_PCE_Competitia 2011...Microsenzorii stocastici ca noi instrumente de masurare a substantelor

PAI-1

Electroactive

material

Matrix Calibration

equation

Linear

conc.

range

toff

(s)

Sensitivity (mg/s . mL)

P DP 1/ton=0.04 + 3.9 x c

R = 0.9626 5ng/mL – 5µg/mL 7.2 3.90x103

MD DP 1/ton=0.06 + 3.8 x c

R = 0.9966 50ng/mL – 5µg/mL 3.6 3.37x103

MD Graphite

1/ton=0.01 + 9.43 x 103 x c

R = 0.9998 50pg/mL – 5ng/mL 9.9 9.43x106

MD Graphene

1/ton=0.07 + 4.50 x 102 x c

R = 0.9745 50pg/mL – 50ng/mL 2.6 4.50x105

MD CNT 1/ton=0.05 + 3.31 x 102 x c

R = 0.9695

500pg/mL –

50ng/mL 2.8 3.31x105

MD C60

1/ton=0.02 + 1.2 x 101 x c

R = 0.9996 50ng/mL – 5µg/mL 5.6 1.20x104

PATLAB

Page 6: Microsenzorii stocastici ca noi instrumente de masurare a ...uefiscdi.gov.ro/userfiles/file/PN II_PCE_Competitia 2011...Microsenzorii stocastici ca noi instrumente de masurare a substantelor

Scanarea probelor de sange pentru leptin.

Sample Leptin, pg/mL

P/DP MD/DP -CD/DP MD/C60 MD/

Graphite

MD/

Graphene

MD/CNT

1 10.1 15.0 11.7 15.6 9.87 10.0 10.4

2 14.0 19.0 12.0 10.0 10.0 14.0 16.0

3 1.00 1.00 1.46 1.73 1.35 1.60 1.36

4 10.0 10.0 14.8 19.0 11.7 10.0 14.0

5 3.00 3.00 3.49 2.80 3.30 3.73 3.30

PATLAB

Page 7: Microsenzorii stocastici ca noi instrumente de masurare a ...uefiscdi.gov.ro/userfiles/file/PN II_PCE_Competitia 2011...Microsenzorii stocastici ca noi instrumente de masurare a substantelor

Scanarea probelor de sange pentru PAI-1.

Sample PAI-1, pg/mL

P/DP MD/DP -CD/DP MD/C60 MD/

Graphite

MD/

Graphene

MD/CNT

1 108 119 99.0 106 107 105 109

2 105 109 97.0 103 136 105 100

3 146 180 130 120 135 100 136

4 466 441 410 440 488 420 490

5 508 500 538 573 563 510 560

PATLAB

Page 8: Microsenzorii stocastici ca noi instrumente de masurare a ...uefiscdi.gov.ro/userfiles/file/PN II_PCE_Competitia 2011...Microsenzorii stocastici ca noi instrumente de masurare a substantelor

Este necesara o metoda de scanare a salivei

copiilor pentru BPA.

*http://wakeup-world.com/2014/05/11/10-things-to-know-about-bpa-bisphenol-a/ *http://www.stats.org/stories/2009/science_suppressed_BPA_intro_jun12_09.html

*

BPA poate contribui la obezitatea copiilor

PATLAB

Page 9: Microsenzorii stocastici ca noi instrumente de masurare a ...uefiscdi.gov.ro/userfiles/file/PN II_PCE_Competitia 2011...Microsenzorii stocastici ca noi instrumente de masurare a substantelor

Caracteristicile de raspuns ale microsenzorilor stocastici

Matricea Materialul

Electroactiv

Ecuatia de calibrare si

coeficientul de corelatie*

Domeniul

linear de

concentratie

(mol/L)

toff (s) Sensibilitatea

(s mol L-1)

Graphene

MD

1/ton= 0.04 + 3.62 x 1011 x C

r=0.9999 10-15 – 10-13 6.6 3.62 x 1011

CNT 1/ton= 0.10 + 6.37 x 1011 x C

r=0.9999 10-15 – 10-13 8.2 6.37 x 1011

C60 1/ton= 0.04 + 1.33 x 1010 x C

r=0.9994 10-14 – 10-12 9.2 1.33 x 1010

PATLAB

Page 10: Microsenzorii stocastici ca noi instrumente de masurare a ...uefiscdi.gov.ro/userfiles/file/PN II_PCE_Competitia 2011...Microsenzorii stocastici ca noi instrumente de masurare a substantelor

Microsenzor

bazat pe

1 2 3 4 5 6 7 8 9 10 11 12

MD/C60 0.11 0.52 0.86 0.38 0.73 0.40 0.01 0.27 0.22 0.17 0.02 0.01

MD/CNT 0.14 0.53 0.87 0.39 0.74 0.46 0.01 0.26 0.23 0.15 0.01 0.03

MD/Graphene 0.15 0.56 0.80 0.36 0.85 0.56 0.01 0.20 0.18 0.20 0.03 0.02

ELISAa 0.12 0.56 0.87 0.45 0.74 0.56 -b 0.25 0.34 0.43 -b -b

Determinarea BPA (µg/mL) in saliva

copiilor

PATLAB

Page 11: Microsenzorii stocastici ca noi instrumente de masurare a ...uefiscdi.gov.ro/userfiles/file/PN II_PCE_Competitia 2011...Microsenzorii stocastici ca noi instrumente de masurare a substantelor

time (sec)

0 200 400 600 800 1000 1200 1400

I (A

)

-400x10-12

-300x10-12

-200x10-12

-100x10-12

0

100x10-12

200x10-12

300x10-12

400x10-12

toff

ton

Time (sec)

0 200 400 600 800 1000 1200 1400

I (A

)

-300x10-12

-200x10-12

-100x10-12

0

100x10-12

200x10-12

300x10-12

400x10-12 toff

ton

time (sec)

0 200 400 600 800 1000 1200 1400

I (A

)

-150x10-12

-100x10-12

-50x10-12

0

50x10-12

100x10-12

150x10-12

ton

toff

MD/C60 MD/GRAPHENE

MD/CNT

Diagrame obtinute pentru determinarea BPA in saliva copiilor

Page 12: Microsenzorii stocastici ca noi instrumente de masurare a ...uefiscdi.gov.ro/userfiles/file/PN II_PCE_Competitia 2011...Microsenzorii stocastici ca noi instrumente de masurare a substantelor

PATLAB

Test de scanare pentru DHT, E2, T2

Page 13: Microsenzorii stocastici ca noi instrumente de masurare a ...uefiscdi.gov.ro/userfiles/file/PN II_PCE_Competitia 2011...Microsenzorii stocastici ca noi instrumente de masurare a substantelor

Caracteristicile de raspuns ale microsenzorilor stocastici

Microsenzori bazati pe DP

si

Ecuatiile de calibrare si

coeficientii de corelatie (r)

Domeniul linear de

concentratie

(mol/L)

toff

(s)

Sensibilitatea

(s/mol L-1)

DHT

P 1/ton=0.05 + 1.86 x 1010 x c

r=0.9853 10-14 – 10-12 4.0 1.86 x 1010

MD 1/ton=0.08 + 2.65 x 1011 x c

r=0.9996 10-15 – 10-13 1.8 2.65 x 1011

-CD 1/ton=0.05 + 6.92 x 108 x c

r=0.9825 10-13 – 10-11 5.1 6.92 x 108

T2

P 1/ton=0.065 + 1.27 x 106 x c

r=0.9942 10-10 – 10-8 5.3 1.27 x 106

MD 1/ton=0.061 + 1.95 x 108 x c

r=0.9989 10-12 – 10-10 3.5 1.95 x 108

-CD 1/ton=0.069 + 1.27 x 107 x c

r=0.9999 10-11 – 10-9 3.1 1.27 x 107

E2

P 1/ton=0.03 + 2.51 x 109 x c

r=0.9987 6.59 x 10-14 – 6.59 x 10-12 7.4 2.51 x 109

MD 1/ton=0.02 + 3.50 x 105 x c

r=0.9966 6.59 x 10-11 – 6.59 x 10-8 8.5 3.50 x 105

-CD 1/ton=0.06 + 1.83 x 109 x c

r=0.9976 6.59 x 10-14 – 6.59 x 10-12 5.2 1.83 x 109

Page 14: Microsenzorii stocastici ca noi instrumente de masurare a ...uefiscdi.gov.ro/userfiles/file/PN II_PCE_Competitia 2011...Microsenzorii stocastici ca noi instrumente de masurare a substantelor

Determinarea hormonilor (pg/mL) in saliva

copiilor

aELISA (metoda standard). bELISA nu a putut determina analitul.

Microsenzor

bazat pe DP

si

1 2 3 4 5 6 7 8 9 10 11 12

F F F F F F M M M M M M

T2

-CD/DP 3.1 0.3 1.2 1.3 3.3 1.7 2.3 2.1 1.0 1.1 1.7 1.1

P/DP 3.3 0.3 2.2 1.7 3.9 1.9 2.7 1.9 1.3 1.4 1.7 1.3

MD/DP 3.2 0.3 1.9 1.1 3.3 1.1 2.2 1.8 1.1 1.2 1.6 1.5

ELISAa -b 0.7 1.1 0.4 0.6 0.9 1.0 1.4 1.1 0.5 0.6 0.3

DHT

-CD/DP 0.3 0.3 0.3 0.2 0.1 0.3 0.3 0.3 0.3 0.1 0.2 0.2

P/DP 0.2 0.2 0.4 0.2 0.1 0.4 0.2 0.2 0.2 0.2 0.2 0.1

MD/DP 0.2 0.3 0.3 0.1 0.1 0.4 0.3 0.3 0.2 0.1 0.1 0.3

ELISAa -b -b 0.2 0.4 0.2 0.5 0.4 0.7 0.8 0.4 1.1 0.3

E2

-CD/DP 1.9 2.9 1.1 1.1 2.3 2.2 1.8 1.7 0.2 1.0 0.8 0.9

P/DP 1.7 2.3 1.0 1.0 2.2 2.0 1.4 1.5 0.6 1.3 1.0 1.0

MD/DP 1.1 2.7 1.2 1.5 2.6 1.5 1.6 1.4 0.7 1.0 0.8 1.6

ELISAa 1.8 1.7 1.3 1.1 1.5 2.0 1.3 1.7 0.5 1.1 1.0 0.9

Page 15: Microsenzorii stocastici ca noi instrumente de masurare a ...uefiscdi.gov.ro/userfiles/file/PN II_PCE_Competitia 2011...Microsenzorii stocastici ca noi instrumente de masurare a substantelor

Analiza DHT, E2, T2 in saliva utilizand microsenzorul bazat pe P/DP

Page 16: Microsenzorii stocastici ca noi instrumente de masurare a ...uefiscdi.gov.ro/userfiles/file/PN II_PCE_Competitia 2011...Microsenzorii stocastici ca noi instrumente de masurare a substantelor

Analiza DHT, E2, T2 in saliva utilizand microsenzorul bazat pe MD/DP

DHT T2 E2

Page 17: Microsenzorii stocastici ca noi instrumente de masurare a ...uefiscdi.gov.ro/userfiles/file/PN II_PCE_Competitia 2011...Microsenzorii stocastici ca noi instrumente de masurare a substantelor

Analiza DHT, E2, T2 in saliva utilizand microsenzorul bazat pe -CD/DP

Page 18: Microsenzorii stocastici ca noi instrumente de masurare a ...uefiscdi.gov.ro/userfiles/file/PN II_PCE_Competitia 2011...Microsenzorii stocastici ca noi instrumente de masurare a substantelor

HEPATITA B

Scanarea sangelui pentru

hepatita B si cancer !!!

PATLAB

Page 19: Microsenzorii stocastici ca noi instrumente de masurare a ...uefiscdi.gov.ro/userfiles/file/PN II_PCE_Competitia 2011...Microsenzorii stocastici ca noi instrumente de masurare a substantelor

Biomarkeri

• Cancer de san:

- CA15-3

• Hepatita B:

- HBvAg

- Acid D-pipecolic (D-PA)

Page 20: Microsenzorii stocastici ca noi instrumente de masurare a ...uefiscdi.gov.ro/userfiles/file/PN II_PCE_Competitia 2011...Microsenzorii stocastici ca noi instrumente de masurare a substantelor

Caracteristicile de raspuns ale senzorului

multimode bazat pe MD/DP, determinate in

modul stocastic.

Biomarker toff

(s)

Domeniul linear de

concentratie

Sensibilitate Ecuatie de calibrared

CA15-3 3.3 5 – 500 a 44mU s/mL 1/ton= 20.11 + 0.044xC;a

R= 0.9608

HBVAg 1.9 10-10-10-8 b 3.9 x 105 g s/mL 1/ton= 0.05 + 3.9x105xC;b

R= 0.9997

D-PA 4.9 10-12-10-10 c 3.0 x 108 mol s/L 1/ton= 0.02 + 3.0x108xC;c

R= 0.9488

aU/mL; bg/mL; cmol/L; d<ton> = s.

Page 21: Microsenzorii stocastici ca noi instrumente de masurare a ...uefiscdi.gov.ro/userfiles/file/PN II_PCE_Competitia 2011...Microsenzorii stocastici ca noi instrumente de masurare a substantelor

Caracteristicile de raspuns ale senzorului

multimode bazat pe MD/DP, determinate in

modul DPV.

Biomarker E

(mV)

Linear

concentration

range

Sensitivity Equation of calibration

CA15-3 780 5 – 500 a 5pA U/mL H= 0.3 + 5.0xC;a,d

R= 0.9382

HBVAg 526 10-12- 5x10-9 b 2.9nA g/mL H= 3.1 + 2.9xC;b,e

R= 0.9976

D-PA 350 10-11-10-8 c 155.4pA mol/L H= 0.2 + 0.16xC;c,e

R= 0.9915

aU/mL; bg/mL; cmol/L; d<H>=pA; e<H>=nA

E(mV)

0.68 0.70 0.72 0.74 0.76 0.78 0.80 0.82 0.84 0.86 0.88

I(A

)

-5.0e-11

0.0

5.0e-11

1.0e-10

1.5e-10

2.0e-10

2.5e-10

3.0e-10

3.5e-10

E(mV)

0.25 0.30 0.35 0.40 0.45 0.50 0.55 0.60 0.65

I(A

)

-2.0e-10

0.0

2.0e-10

4.0e-10

6.0e-10

8.0e-10

1.0e-9

1.2e-9

E(mV)

0.1 0.2 0.3 0.4 0.5 0.6

I(A

)

0.0

2.0e-10

4.0e-10

6.0e-10

8.0e-10

1.0e-9

1.2e-9

1.4e-9

1.6e-9

1.8e-9

D-PA 1x10-12mol/L

Page 22: Microsenzorii stocastici ca noi instrumente de masurare a ...uefiscdi.gov.ro/userfiles/file/PN II_PCE_Competitia 2011...Microsenzorii stocastici ca noi instrumente de masurare a substantelor

Analiza calitativa a biomarkerilor in probele de

sange.

Biomarker Sample 1 Sample 2 Sample 3

Stochastic

mode

Standard

method

Stochastic

mode

Standard

method

Stochastic

mode

Standard

method

CA15-3 + + + + + +

HBVAg + + + + + +

D-PA + + + + + +

Page 23: Microsenzorii stocastici ca noi instrumente de masurare a ...uefiscdi.gov.ro/userfiles/file/PN II_PCE_Competitia 2011...Microsenzorii stocastici ca noi instrumente de masurare a substantelor

E(mV)

0.0 0.2 0.4 0.6 0.8 1.0

I(A

)

-2e-10

0

2e-10

4e-10

6e-10

8e-10

1e-9

Determinarea cantitativa a biomarkerilor direct

din sange.

Biomarker Sample 1 Sample 2 Sample 3

M1 M2 Std M1 M2 Std M1 M2 Std

CA15-3a 10.2 10.8 9.6 43.7 42.9 42.0 87.2 87.9 86.0

HBVAgb 420 419 417 327 327 324 529 528 524

D-PAc 325 326 320 219 216 211 625 627 620

CA15-3 HBVAg

D-PA

Sample 2

t(s)

0 100 200 300 400

I(A

)

-1e-10

-8e-11

-6e-11

-4e-11

-2e-11

0

2e-11

4e-11

6e-11

8e-11

1e-10 D-PA HBVAg CA15-3

Page 24: Microsenzorii stocastici ca noi instrumente de masurare a ...uefiscdi.gov.ro/userfiles/file/PN II_PCE_Competitia 2011...Microsenzorii stocastici ca noi instrumente de masurare a substantelor

Diseminarea rezultatelor

Capitol in carte:

Mechanism of potential development for potentiometric sensors, based on modeling of interaction between electrochemically active compounds from the membrane and analyte

R.I. Stefan-van Staden

Chapter 4, pp.131-154 in

Chemical Sensors Simulation and Modeling

Volume 5: Electrochemical Sensors (Ghenadii Korotcenkov, Ed)

Published in Sensors Technology Series (Joe Watson, Ed.)

Momentum Press, LLC, New York, 2013.

Page 25: Microsenzorii stocastici ca noi instrumente de masurare a ...uefiscdi.gov.ro/userfiles/file/PN II_PCE_Competitia 2011...Microsenzorii stocastici ca noi instrumente de masurare a substantelor

Diseminarea rezultatelor 1. Stochastic sensors based on nanostructured materials used in the screening of

whole blood for hepatitis B. R.I. Stefan-van Staden, I. Moldoveanu J Electrochem Soc, 161(2), B3001-B3005, 2014

2. New tool for screening of whole blood for early detection of breast cancer antigen (CA153). R.I. Stefan-van Staden, J.F. van Staden J. Mod.Med.Chem., 1(2), 86-91, 2013

3. Enantioselective Surface Plasmon Resonance Sensor Based on C60 Fullerene-Glutathione Self-Assembled Monolayer (SAM). R.I. Stefan-van Staden. Chirality, 26(3), 129-131, 2014

4. New Multimode Sensors based on Nanostructured Materials for Simultaneous Screening of Biological Fluids for Specific Breast Cancer and Hepatitis B Biomarkers. R.I. Stefan-van Staden, I. Moldoveanu J Electrochem Soc, 161(4), B45-B48, 2014

5. A new genetic test for obesity, based on stochastic sensors. Raluca-Ioana Stefan-

van Staden, Livia Alexandra Gugoasa. J Electrochem Soc, 161(9), B167-B170, 2014

6. Screening of children saliva samples for bisphenol A using stochastic, amperometric and multimode microsensors. R.I. Stefan-van Staden, L.A. Gugoasa, B. Calenic, J.F. van Staden, J Legler Analytical Chemistry Research, 1, 000, 2014

Page 26: Microsenzorii stocastici ca noi instrumente de masurare a ...uefiscdi.gov.ro/userfiles/file/PN II_PCE_Competitia 2011...Microsenzorii stocastici ca noi instrumente de masurare a substantelor

Diseminarea rezultatelor

1. Analysis of L-thyroxine and 3,3’,5-triiodo-L-thyronine using potentiometric

microsensors. Iuliana Moldoveanu, Raluca-Ioana Stefan-van Staden, Jacobus

Frederick van Staden, Gabriel Lucian Radu U.P.B. Sci. Bull., In Press.

2. Amperometric microsensors based on inulins for the assay of L-T3 and L-T4.

Livia Alexandra Gugoasa, Raluca-Ioana van Staden, Grzegorz Bazylak,

Jacobus Frederick van Staden, Gabriel-Lucian Radu U.P.B. Sci. Bull., In Press.

Page 27: Microsenzorii stocastici ca noi instrumente de masurare a ...uefiscdi.gov.ro/userfiles/file/PN II_PCE_Competitia 2011...Microsenzorii stocastici ca noi instrumente de masurare a substantelor

Implicarea tinerilor

• Iuliana Moldoveanu – doctorand

• Livia Alexandra Gugoasa – doctorand

• Ionela Raluca Comnea – doctorand

• Ramona Georgescu - doctorand

• Dr Bogdan Calenic – postdoc

• Oana Elena Stoica – asistent tehnician

• Anita Girbea – masterand

• Radu Constantin Iacomin - masterand