microscope ppt, by jitendra kumar pandey,medical micro,2nd yr, mgm medical college mumbai

76
Jitendra kumar pandey PG, Med. Microbiology 2 nd year

Upload: jitu-pandey

Post on 07-May-2015

10.982 views

Category:

Education


5 download

DESCRIPTION

information about all microscope ,

TRANSCRIPT

Page 1: Microscope ppt, by jitendra kumar pandey,medical micro,2nd yr, mgm medical college mumbai

Jitendra kumar pandey

PG, Med. Microbiology

2nd year

Page 2: Microscope ppt, by jitendra kumar pandey,medical micro,2nd yr, mgm medical college mumbai

INTRODUCTION

Microscope is the biggest tool for us Microscope is the biggest tool for us to reveal the mystery and beauty of to reveal the mystery and beauty of the unseen world. the unseen world.

Antony van Leeuwenhoek (1632-Antony van Leeuwenhoek (1632-1723)1723)

Robert Hook(1678)Robert Hook(1678)

Page 3: Microscope ppt, by jitendra kumar pandey,medical micro,2nd yr, mgm medical college mumbai

DEFINITION

Microscope may be defined as an Microscope may be defined as an optical instrument consisting of a optical instrument consisting of a lens or combination of lenses for lens or combination of lenses for making anmaking an

enlarged or magnified image of a enlarged or magnified image of a minute object.minute object.

Page 4: Microscope ppt, by jitendra kumar pandey,medical micro,2nd yr, mgm medical college mumbai

Microscopes use lenses to bend and Microscopes use lenses to bend and focus light rays to produce enlarged focus light rays to produce enlarged images of small objects. images of small objects.

There are mainly two groups based There are mainly two groups based on source of illumination.on source of illumination.

Page 5: Microscope ppt, by jitendra kumar pandey,medical micro,2nd yr, mgm medical college mumbai

TYPES

Light Microscope : use sunlight or artificial light.

1. Bright field microscope.

2. Dark field microscope.

3. Phase contrast microscope.

4. Fluorescence microscope. Electron microscope : use of electron.

1. Transmission electron microscope.

2. Scanning electron microscope.

Page 6: Microscope ppt, by jitendra kumar pandey,medical micro,2nd yr, mgm medical college mumbai

LIGHT MICROSCOPY

Page 7: Microscope ppt, by jitendra kumar pandey,medical micro,2nd yr, mgm medical college mumbai

Light Microscopy

Microscopes are of great importance in the study of microorganisms and biomolecules.

Light microscopes are simplest of all microscopes.

Light microscopes use lenses to bend and focus light rays to produce enlarged images of small objects.

Page 8: Microscope ppt, by jitendra kumar pandey,medical micro,2nd yr, mgm medical college mumbai

Types of Light Microscope. Bright-field Microscopy. Dark-field Microscopy. Phase contrast Microscopy. Fluorescence Microscopy.

Page 9: Microscope ppt, by jitendra kumar pandey,medical micro,2nd yr, mgm medical college mumbai

WORKING OF COMPOUND MICROSCOPE

Light is transmitted and focussed by mirror and condenser.

Focussed light illuminate the object or specimen.

The refracted light is collected by an objective where primary image of the object is formed, it is real,inverted enlarged image of the object.

The eyepiece further magnifies this primary image into virtual,erect enlarged image, this is the final image that lies above the stage.

Page 10: Microscope ppt, by jitendra kumar pandey,medical micro,2nd yr, mgm medical college mumbai

APPLICATION

Observation of morphology of microorganisms.

Detection of cell structures. Observation of intracellular structures. Observation of motility. Measurement of size. Observation of blood smears.

Page 11: Microscope ppt, by jitendra kumar pandey,medical micro,2nd yr, mgm medical college mumbai
Page 12: Microscope ppt, by jitendra kumar pandey,medical micro,2nd yr, mgm medical college mumbai
Page 13: Microscope ppt, by jitendra kumar pandey,medical micro,2nd yr, mgm medical college mumbai

The useful magnification of Light microscope is limited by its resolving power.

The resolving power in limited by wavelength of illuminating beam.

Resolution is determine by certain physical parameters like wave length of light and light generating power of the objective & condenser lens.

Page 14: Microscope ppt, by jitendra kumar pandey,medical micro,2nd yr, mgm medical college mumbai

Higher N.A

Better light generation

Better Resolution

Shorter the Wavelength

Better Resolution.

Page 15: Microscope ppt, by jitendra kumar pandey,medical micro,2nd yr, mgm medical college mumbai

The ordinary microscope is called as a The ordinary microscope is called as a bright field microscop.bright field microscop.

It forms dark image against bright It forms dark image against bright background.background.

Page 16: Microscope ppt, by jitendra kumar pandey,medical micro,2nd yr, mgm medical college mumbai

Structure It consist of sturdy metal body or stand, a

base, and arm. A light source either a mirror or an

electronic illuminator located in the base. Two focusing knobs are located on the

arm. A stage is positioned about halfway up the

arm and holds slide clip or stage clip.

Page 17: Microscope ppt, by jitendra kumar pandey,medical micro,2nd yr, mgm medical college mumbai

Bright Field Microscopy

Page 18: Microscope ppt, by jitendra kumar pandey,medical micro,2nd yr, mgm medical college mumbai

The sub stage condenser is mounted beneath the stage and focuses a cone of light on the slide.

The curve upper arm holds body assembly to which nosepiece and ocular lens or eyepiece are attached.

The nose piece holds three or five objective lenses of different magnifying power.

Page 19: Microscope ppt, by jitendra kumar pandey,medical micro,2nd yr, mgm medical college mumbai

These lenses can be rotated to position any objective beneath the body assembly.

Ideally the microscope should be parafocal. Parafocal- Image should remain in focus when

objective are changed For bright field microscopy staining of

organism is required

Page 20: Microscope ppt, by jitendra kumar pandey,medical micro,2nd yr, mgm medical college mumbai

How Image is formed

Page 21: Microscope ppt, by jitendra kumar pandey,medical micro,2nd yr, mgm medical college mumbai

How Image is formed

Page 22: Microscope ppt, by jitendra kumar pandey,medical micro,2nd yr, mgm medical college mumbai

Image is created by objective and ocular lenses working together.

Light from illuminated specimen is focused by the objective lens creating enlarged image within the microscope.

The ocular lens further modifies the primary image.

Page 23: Microscope ppt, by jitendra kumar pandey,medical micro,2nd yr, mgm medical college mumbai

Total magnification is calculated by magnification by objective multiply by magnification by eyepiece.

Ex : 45x X 10x =450x

Page 24: Microscope ppt, by jitendra kumar pandey,medical micro,2nd yr, mgm medical college mumbai

Image formed by bright field microscopy

Page 25: Microscope ppt, by jitendra kumar pandey,medical micro,2nd yr, mgm medical college mumbai

Advantages

Bright field compound microscopes are commonly used to view live and immobile specimens such as bacteria, cells, and tissues. For transparent or colorless specimens, however, it is important that they be stained first so that they can be properly viewed under this type of a microscope. Staining is achieved with the use of a chemical dye. By applying it, the specimen would be able to adapt the color of the dye. Therefore, the light won’t simply pass through the body of the specimen showing nothing on the microscope’s view field

Page 26: Microscope ppt, by jitendra kumar pandey,medical micro,2nd yr, mgm medical college mumbai

Dark field Microscopy

Page 27: Microscope ppt, by jitendra kumar pandey,medical micro,2nd yr, mgm medical college mumbai

Dark field microscopy allows viewer to observe living unstained cell and organisms simply by changing the way in which they illuminate the object.

A hollow cone of light is focused on the specimen in such a way that unreflected and unrefracted rays do not enter the objective.

Page 28: Microscope ppt, by jitendra kumar pandey,medical micro,2nd yr, mgm medical college mumbai

Only light that has been reflected or refracted by the specimen forms the image

The field surrounding specimen appears dark while the object brightly illuminated.

The dark field microscope can revel considerable internal structure in larger eukaryotic microorganism.

Page 29: Microscope ppt, by jitendra kumar pandey,medical micro,2nd yr, mgm medical college mumbai

How image formed in dark field microscopy

Page 30: Microscope ppt, by jitendra kumar pandey,medical micro,2nd yr, mgm medical college mumbai

Advantages

The advantage of darkfield microscopy also becomes its disadvantage: not only the specimen, but dust and other particles scatter the light and are easily observed

For example, not only the cheek cells but the bacteria in saliva are evident.

The dark field microscopes divert illumination and light rays thus, making the details of the specimen appear luminous.

Page 31: Microscope ppt, by jitendra kumar pandey,medical micro,2nd yr, mgm medical college mumbai

Dark field light microscopes provide good results, especially through the examination of live blood samples.

It can yield high magnifications of living bacteria and low magnifications of the tissues and cells of certain organisms.

Certain bacteria and fungi can be studied with the use of dark field microscopes.

Page 32: Microscope ppt, by jitendra kumar pandey,medical micro,2nd yr, mgm medical college mumbai
Page 33: Microscope ppt, by jitendra kumar pandey,medical micro,2nd yr, mgm medical college mumbai

DEFINITION

Phase contrast microscopy is an optical Phase contrast microscopy is an optical illumination technique in which small phase illumination technique in which small phase shifts in the light passing through a transparent shifts in the light passing through a transparent specimen are converted into amplitude or specimen are converted into amplitude or contrast changes in the image. contrast changes in the image.

The technique was invented by Frits Zernite in The technique was invented by Frits Zernite in the 1930s for which he received the Nobel the 1930s for which he received the Nobel prize in physics in 1953 . prize in physics in 1953 .

Page 34: Microscope ppt, by jitendra kumar pandey,medical micro,2nd yr, mgm medical college mumbai
Page 35: Microscope ppt, by jitendra kumar pandey,medical micro,2nd yr, mgm medical college mumbai

Application

Applications for phase contrast microscopy Applications for phase contrast microscopy equipment range from the study of living equipment range from the study of living biological specimens, medical applications, biological specimens, medical applications, study of live blood cells, and other study of live blood cells, and other biological and science applicationsbiological and science applications

Most commonly used to provide constrast Most commonly used to provide constrast of transparent specimens such as living of transparent specimens such as living cells or small organisms. cells or small organisms.

Page 36: Microscope ppt, by jitendra kumar pandey,medical micro,2nd yr, mgm medical college mumbai

Phase contrast microscopy is used in study of living cells and tissues.

Microbes and parasites can be study . Useful in observing cells cultured in vitro

during mitosis.

Page 37: Microscope ppt, by jitendra kumar pandey,medical micro,2nd yr, mgm medical college mumbai
Page 38: Microscope ppt, by jitendra kumar pandey,medical micro,2nd yr, mgm medical college mumbai

Why fluorescence microscopy?

In all types of microscopes, cell constituents are not distinguishable, although staining dose , but not totally.

In fluorescent microscopy, various fluorescent dyes are used which gives property of fluorescence to only specific part of the cell and hence it can be focused.

Page 39: Microscope ppt, by jitendra kumar pandey,medical micro,2nd yr, mgm medical college mumbai

Fluorescence Principle

When certain compounds are illuminated with high energy light, they then emit light of a different, lower frequency. This effect is known as fluorescence.

Often specimens show their own characteristic autofluorescence image, based on their chemical makeup.

Page 40: Microscope ppt, by jitendra kumar pandey,medical micro,2nd yr, mgm medical college mumbai
Page 41: Microscope ppt, by jitendra kumar pandey,medical micro,2nd yr, mgm medical college mumbai

Many different fluorescent dyes can be used to stain different structures or chemical compounds.

One particularly powerful method is the combination of antibodies coupled to a fluorochrome as in immunostaining.

Examples of commonly used fluorochromes are fluorescein or rhodamine

Page 42: Microscope ppt, by jitendra kumar pandey,medical micro,2nd yr, mgm medical college mumbai

Fluorescent Microscope

Page 43: Microscope ppt, by jitendra kumar pandey,medical micro,2nd yr, mgm medical college mumbai

A component of interest in the specimen is A component of interest in the specimen is specifically labeled with a fluorescent molecule specifically labeled with a fluorescent molecule called a fluorophore called a fluorophore

The specimen is illuminated with light of a specific The specimen is illuminated with light of a specific wavelength (or wavelengths) which is absorbed by wavelength (or wavelengths) which is absorbed by the fluorophores, causing them to emit longer the fluorophores, causing them to emit longer wavelengths of light (of a different color than the wavelengths of light (of a different color than the absorbed light). absorbed light).

Typical components of a fluorescence microscope Typical components of a fluorescence microscope are the light source (xenon arc lamp or mercury-are the light source (xenon arc lamp or mercury-vapor lamp), the excitation filter, the dichroic mirror vapor lamp), the excitation filter, the dichroic mirror and the emission filter.and the emission filter.

Page 44: Microscope ppt, by jitendra kumar pandey,medical micro,2nd yr, mgm medical college mumbai

The illumination light is separated from the The illumination light is separated from the much weaker emitted fluorescence through the much weaker emitted fluorescence through the use of an emission filter. use of an emission filter.

The filters and the dichroic are chosen to The filters and the dichroic are chosen to match the spectral excitation and emission match the spectral excitation and emission characteristics of the fluorophore used to label characteristics of the fluorophore used to label the specimen. the specimen.

In this manner, a single fluorophore (color) is In this manner, a single fluorophore (color) is imaged at a time. Multi-color images of several imaged at a time. Multi-color images of several fluorophores must be composed by combining fluorophores must be composed by combining several single-color images.several single-color images.

Page 45: Microscope ppt, by jitendra kumar pandey,medical micro,2nd yr, mgm medical college mumbai
Page 46: Microscope ppt, by jitendra kumar pandey,medical micro,2nd yr, mgm medical college mumbai
Page 47: Microscope ppt, by jitendra kumar pandey,medical micro,2nd yr, mgm medical college mumbai
Page 48: Microscope ppt, by jitendra kumar pandey,medical micro,2nd yr, mgm medical college mumbai
Page 49: Microscope ppt, by jitendra kumar pandey,medical micro,2nd yr, mgm medical college mumbai

Applications

Fluorescence microscopy is a critical tool for academic and pharmaceutical research, pathology, and clinical medicine.

Page 50: Microscope ppt, by jitendra kumar pandey,medical micro,2nd yr, mgm medical college mumbai
Page 51: Microscope ppt, by jitendra kumar pandey,medical micro,2nd yr, mgm medical college mumbai

INTRODUCTION

Electron microscope is a type of microscope that uses a particle beam of electrons to illuminate a specimen & create a highly-magnified image.

Co-invented by Germans, Max Knoll and Ernst Ruska in 1931

Page 52: Microscope ppt, by jitendra kumar pandey,medical micro,2nd yr, mgm medical college mumbai

Electron microscopes have much greater resolving power than light microscopes & can obtain much higher magnifications of up to 2 million times, while the best light microscopes are limited to magnifications of 2000 times. 

Can be used to study the Topography, Morphology, Composition & Crystallographic Information.

Page 53: Microscope ppt, by jitendra kumar pandey,medical micro,2nd yr, mgm medical college mumbai

Structure

Page 54: Microscope ppt, by jitendra kumar pandey,medical micro,2nd yr, mgm medical college mumbai

Structure Electron Gun: 2 types of guns- Thermionic

Emission Gun & Field Emission Gun. Thermionic: Electrons emitted from heated

filament ( tungsten, Lanthanum Hexaboride). Most common, cheap & ultra high vaccum not required.

Field Emission: Strong electron field used to extract electrons from filament. High vaccum needed.

Page 55: Microscope ppt, by jitendra kumar pandey,medical micro,2nd yr, mgm medical college mumbai

Structure Electromagnetic lens:

An electromagnet designed to produce a suitably shaped magnetic field for focusing & deflection of electrons in electron optical instruments.

A strong magnetic field is generated by passing a current through a set of windings. This field acts as a convex lens in case of electron microscope.

Page 56: Microscope ppt, by jitendra kumar pandey,medical micro,2nd yr, mgm medical college mumbai

Structure First condenser lens: The

first lens(controlled by "spot size knob") largely determines the "spot size"; the general size range of the final spot that strikes the sample.

Second condenser lens: The second lens(controlled by the "intensity/ brightness knob" changes the size of the spot on the sample; changing it from a wide dispersed spot to a pinpoint beam.

Page 57: Microscope ppt, by jitendra kumar pandey,medical micro,2nd yr, mgm medical college mumbai

Structure The other parts include

condenser aperture, objective lens, objective aperture, selected area aperture(to examine diffraction patterns), Intermediate lens(magnifies initial image formed by objective lens) & projector lens.

Page 58: Microscope ppt, by jitendra kumar pandey,medical micro,2nd yr, mgm medical college mumbai

TYPES There are 2 types of

electron microscopes: Transmission Electron

Microscope:Process is carried out under vaccum to avoid friction.

The "Virtual Source" at the top represents the electron gun, producing a stream of monochromatic electrons. The usual potential is around 10000 – 15000V.

Page 59: Microscope ppt, by jitendra kumar pandey,medical micro,2nd yr, mgm medical college mumbai

TEM This stream is focused

to a small, thin, coherent beam by the condenser lenses 1 & 2.

The beam is restricted by condenser aperture knocking out high angle electrons.

The beam strikes the specimen and parts of it are transmitted.

Page 60: Microscope ppt, by jitendra kumar pandey,medical micro,2nd yr, mgm medical college mumbai

TEM This transmitted portion is focused by the objective

lens into an image. The Objective & Selected Area metal apertures restrict

the beam. The image is passed down the column through the

intermediate and projector lenses, being enlarged all the way.

The image strikes the phosphor image screen & light is generated, allowing the user to see the image. The darker areas represent areas that fewer electrons were transmitted (thicker or denser). The lighter areas represent areas that more electrons were transmitted (thinner or less dense)

Page 61: Microscope ppt, by jitendra kumar pandey,medical micro,2nd yr, mgm medical college mumbai

TEM A TEM images using the electrons that pass through it- Unscattered Electrons, Elastically Scattered Electrons , Inelasticity Scattered electrons. TEM transmits electrons through a sample that has been cut so that it is only a few molecules thin & it reveals internal details of sample.Good resolution power up to 0.2 – 0.3nm.

Page 62: Microscope ppt, by jitendra kumar pandey,medical micro,2nd yr, mgm medical college mumbai

SCANNING ELECTRON MICROSCOPE

 The 1st  scanning electron microscope (SEM) debuted in 1938 by Von Ardenne with the first commercial instruments out around 1965.

In this case electrons are not used to directly image the specimen, but to excite it in such a way that it gives out secondary electrons which are collected by detectors & used to form the image.

Page 63: Microscope ppt, by jitendra kumar pandey,medical micro,2nd yr, mgm medical college mumbai

SEM The "Virtual Source" at the

top represents the electron gun, producing a stream of monochromatic electrons.

The stream is condensed by 1st condenser lens (controlled by "coarse probe current knob"). This lens is used to both form the beam and limit the amount of current in the beam.

Page 64: Microscope ppt, by jitendra kumar pandey,medical micro,2nd yr, mgm medical college mumbai

SEM The beam is then constricted by the

condenser aperture eliminating some high-angle electrons

The second condenser lens forms electrons into a thin, tight, coherent beam & is controlled by "fine probe current knob"

The objective aperture further eliminates high-angle electrons from the beam

Page 65: Microscope ppt, by jitendra kumar pandey,medical micro,2nd yr, mgm medical college mumbai

SEM A set of coils then "scan" or "sweep" the

beam dwelling on points for a period of time determined by the scan speed (usually in the s range)

The Objective lens, focuses the scanning beam onto part of the specimen desired.

When the beam strikes the sample (for few s) interactions occur inside the sample and are detected by release of electrons.

Page 66: Microscope ppt, by jitendra kumar pandey,medical micro,2nd yr, mgm medical college mumbai

SEM Before the beam moves to its next dwell

point these instruments count the number of interactions and display a pixel whose intensity is determined by this number (the more reactions the brighter the pixel).

The interactions lead to release of – secondary electrons, backscattered electrons & X- rays.

Page 67: Microscope ppt, by jitendra kumar pandey,medical micro,2nd yr, mgm medical college mumbai

Sample Preparation - TEM Specimen is required to be completely dry. chemical fixation is required to preserve and

stabilize the structure of specimen. Fixation is usually performed by incubation in

a solution such as glutaraldehyde to cross- link proteins & followed by postfixation with osmium tetroxide to fix & stain lipid membranes.

Page 68: Microscope ppt, by jitendra kumar pandey,medical micro,2nd yr, mgm medical college mumbai

Sample Preparation - TEM The fixed tissue is then dehydrated. Because air-

drying causes collapse and shrinkage, this is commonly achieved by critical point drying, which involves replacement of water in the cells with organic solvents such as ethanol or acetone.

After dehydration, tissue for observation is embedded so it can be sectioned ready for viewing. To do this the tissue is passed through a 'transition solvent' such as epoxy propane and then infiltrated with a resin such as Araldite epoxy resin. After the resin has been polymerised the sample is thin sectioned (ultrathin sections)

Page 69: Microscope ppt, by jitendra kumar pandey,medical micro,2nd yr, mgm medical college mumbai

Sample Preparation - TEM Sectioning – produces thin slices of

specimen, semitransparent to electrons. These can be cut on an ultramicrotome with a diamond knife to produce ultrathin slices about 60-90 nm thick.

Staining – uses salts of heavy metals such as lead, uranium or tungsten to scatter imaging electrons and thus give contrast between different structures.

Page 70: Microscope ppt, by jitendra kumar pandey,medical micro,2nd yr, mgm medical college mumbai

Sample Preparation - SEM Specimen is required to be completely

dry, since the specimen chamber is at high vacuum.

living cells and tissues and whole, soft-bodied organisms usually require chemical fixation to preserve and stabilize their structure.

 Fixation is performed with glutaraldehyde followed with osmium tetroxide .

Page 71: Microscope ppt, by jitendra kumar pandey,medical micro,2nd yr, mgm medical college mumbai

Sample Preparation The fixed tissue is then dehydrated by

replacement of water in the cells with organic solvents such as ethanol or acetone.

The dry specimen is usually mounted on a specimen stub using an adhesive such as epoxy resin & sputter coated with gold before examination in the microscope. Gold has a high atomic number and sputter coating with gold produces high topographic contrast and resolution.

Page 72: Microscope ppt, by jitendra kumar pandey,medical micro,2nd yr, mgm medical college mumbai
Page 73: Microscope ppt, by jitendra kumar pandey,medical micro,2nd yr, mgm medical college mumbai
Page 74: Microscope ppt, by jitendra kumar pandey,medical micro,2nd yr, mgm medical college mumbai

Advantages

Spirillum volutans. Electron micrograph showing individual flagella

Page 75: Microscope ppt, by jitendra kumar pandey,medical micro,2nd yr, mgm medical college mumbai

Leptospira biflexa. Electron micrograph showing axial filament.

Page 76: Microscope ppt, by jitendra kumar pandey,medical micro,2nd yr, mgm medical college mumbai

THANK