microgenus - the...

12
MICROGENUS WALL-HUNG ELECTRONIC IGNITION GAS COMBINATION BOILER COMPACT DESIGN - OUTSTANDING PERFORMANCE

Upload: others

Post on 17-Jul-2020

8 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: microGENUS - The Initiativetheinitiativegroup.org.uk/fscinitiativedatabase/Ariston/microgenus_p… · Air intake Fan Combustion chamber hood Main heat exchanger Safety thermostat

MICROGENUSWALL-HUNG ELECTRONIC IGNITION GAS COMBINATION BOILER

COMPACT DESIGN - OUTSTANDING PERFORMANCE

Page 2: microGENUS - The Initiativetheinitiativegroup.org.uk/fscinitiativedatabase/Ariston/microgenus_p… · Air intake Fan Combustion chamber hood Main heat exchanger Safety thermostat
Page 3: microGENUS - The Initiativetheinitiativegroup.org.uk/fscinitiativedatabase/Ariston/microgenus_p… · Air intake Fan Combustion chamber hood Main heat exchanger Safety thermostat

MICROGENUS – DEVELOPED FROM 50 YEARS OF ARISTON QUALITYThe microGENUS comes closer to satisfying yourneeds and is the result of Ariston’s extensiveexperience within the domestic appliance sectorwhere it has been a leading brand for over 50years, this demonstrates our ability to anticipateconsumer demands.The manufacturing process that guarantees thequality of Ariston boilers has ISO 9001certification. Produced on recently builtmanufacturing lines where each process isconstantly tested, checked and subjected to strictQuality Control to guarantee the long-life and theabsolute reliability of each boiler.For any further needs that may arise afterinstallation, Ariston places the best in technicalsupport and customer service at your disposal,offering swift and highly qualified assistance.

CONTROL PANEL - FUNCTIONALITYWITH EASE OF USEThe microGENUS control panel has all thecontrols that you need and has been designed foreasy and instinctive operation. It features anEconomy/Comfort switch that allows you toimmediately select instant hot water.The panel also features temperature adjustmentknobs and lights that indicate the boiler’soperating status.

The microGENUScombines the mostadvanced centralheating and domestichot water productiontechnologies into anextremely competitiveproduct, with minimiseddimensions, that canbe located almostanywhere. This quiet,reliable and durableboiler is covered by a 2year guarantee that canbe extended to 5 years.

ARISTON MICROGENUS - SMALL IN SIZE,AMPLE IN COMFORT

with optional5 year extendable

guarantee

Page 4: microGENUS - The Initiativetheinitiativegroup.org.uk/fscinitiativedatabase/Ariston/microgenus_p… · Air intake Fan Combustion chamber hood Main heat exchanger Safety thermostat
Page 5: microGENUS - The Initiativetheinitiativegroup.org.uk/fscinitiativedatabase/Ariston/microgenus_p… · Air intake Fan Combustion chamber hood Main heat exchanger Safety thermostat

MICROGENUS - SMALL, LIGHTAND EASY TO INSTALL

In its continuous attention to installerrequirements, Ariston has instilled thebest technical and design solutionsinto the microGENUS, to make itsinstallation easier and possible inextremely tight spaces.The microGENUS is in fact only 30 cmdeep and weighs just 35 kg, allowingeasy handling by a single person. Theflue system is designed to simplifythe problems related to installationsaving time while improving efficiency.Servicing and Maintenance are madesimple and rapid thanks to easyaccess to all components, outlets forthe analysis of combustion productsand the revolutionary new PCB withmicro processor system that allowsall of the boiler functions to betested.The front panel can be easilydismantled by removing a singlescrew!

5 year guarantee on D.H.W. plate

heat exchanger

THE CHARACTERISTICS OF A BOILER WITH LARGERDIMENSIONS WITHOUT ANYCOMPROMISESWith the microGENUS, Ariston hasincreased the level of quality andperformance that is normallyachieved by boilers of much largerdimensions. It is a product that isdecidedly different from othersoffered on the market that need tosacrifice quality or performance toreduce dimensions.The microGENUS is equipped with ananti-frost device, an hour-by-hourprogrammable time clock, an anti-scale system and a comprehensiverange of accessories.

Page 6: microGENUS - The Initiativetheinitiativegroup.org.uk/fscinitiativedatabase/Ariston/microgenus_p… · Air intake Fan Combustion chamber hood Main heat exchanger Safety thermostat

MICROGENUS 27 MFFI

MICROGENUS 23 MFFI Ø 3/4” BSP

Ø 3/4” BSP

Ø 1/2” BSP

Ø 1/2” BSP

Ø 3/4” BSP

Ø 3/4” BSP

Ø 1/2” BSP

Ø 1/2” BSP

Ø 3/4” BSP

Ø 3/4” BSP

Ø mm G1 60/100 - G2 80

Ø mm G1 60/100 - G2 80

ACentral heating flow

BDomestic hot water outlet

DDomestic hot water inlet

ECentral heating return

FFlue (Ø mm)

CGas inlet

• Compact dimensions(300x400x700 mm)

• Aesthetically pleasing design

• Available in 80,000 or 95,000 Btu/h

• Fully modulating in C.H./D.H.W. with an accuracy to ± 1°C

• High performance: High efficiency

• Government Standard AssessmentProcedure (SAP) efficiencyrating up to 80.3%

• Comfort switch (pre-heat function)

• D.H.W. flow rate of up to 11.2 l/min (2.6 gal/min) (95, 000 Btu/h version)

• Anti-frost and anti-scale device

• Built-in automatic by-pass

• Built-in mechanical time clock

• Coaxial flue system up to 4 m,twin pipe flue system up to 27 m

• Split exhaust and intake pipes for built-in combustion analysis

• Direct access to air pressure switch and relative signal

• D.H.W. stainless steel plate heat exchanger guaranteed for 5 years

• 2 year manufacturer's guarantee

• Guarantee extendable up to 5 years

CLEARANCE DIMENSIONS – PIPE FITTINGS – EXHAUST OUTLETS

WALL-HUNG GAS COMBINATION BOILERROOM-SEALED COMBUSTION CHAMBER

MICROGENUS 23 MFFI27 MFFI

Twin pipe exhaust Coaxial exhaust

Fully modulating Electronic ignition

D.H.W. plate heatexchanger

Automatic by-pass

C.H. Tempadjustment

D.H.W. Tempadjustment

P.C.B.adjustment

IPX4D Anti-frost device

Anti-scaledevice

12

3

40bar

Insufficient systempressure shutdown

High efficiency

Page 7: microGENUS - The Initiativetheinitiativegroup.org.uk/fscinitiativedatabase/Ariston/microgenus_p… · Air intake Fan Combustion chamber hood Main heat exchanger Safety thermostat

SCHEMATIC

TECHNICAL INFORMATION

bar

A B D EC

G1

ROOM-SEALED FAN FLUE23 MFFI - 27 MFFI

4

1

23

5

Graph of boiler residual head

flow rate l/h100 200 300 400 500 600 700 800 900 1000 1100 1200 1300

100

200

300

400

500

MICROGENUS23 MFFI

MICROGENUS27 MFFI

FLUE EXHAUST CONNECTION SYSTEM (room-sealed fan flue version)1. Simplified coaxial system coupling.2. Air pressure switch can be accessed directly from the exterior.3. Check the pressure switch is functioning directly from the exterior.4. Separation of the intake.5. External combustion analysis points integrated into the boiler.

Category II 2H3+ II 2H3+Type C* C*

POWERHeat input max. kW - Btu/h 25.6 - 88,000 29.8 - 101,700Heat input min. kW - Btu/h 11.0 - 37,500 12.0 - 41,000Heat output max. kW - Btu/h 23.8 - 81,300 27.8 - 95,000Heat output min. kW - Btu/h 9.7 - 32,000 10.5 - 36,000

EFFICIENCYSEDBUK Rating Band D D

CHARACTERISTICSHeat loss to the casing (∆T= 50°C) % 1.0 0.2Heat loss through the flue when burner on % 6.1 6.3Heat loss through the flue when burner off % 0.4 0.4Maximum exhaust discharge (Natural Gas) kg/h 49.5 60Residual discharge head mbar 0.96 1.60Consumption at nominal capacity G20(1) m3/h 2.72 3.15Gas consumption after 10 minutes* m3 0.32 0.37(15°C, 1013 mbar) G30-G31(1) kg/h 2.02/2.00 2.34/2.31Exhaust gas temperature at nominal capacity °C 123 123.8CO2 content % 7.2 6.9O2 content % 7.5 8.1CO2 content (0% O2) ppm 51.9 48Minimum ambient temperature °C +5 +5Pressure loss through boiler (max) (∆T=20°C) mbar 200 200Residual head of system bar 0.25 0.25Central heating temperature max/min C° 82/42 82/42Domestic hot water temperature max/min C° 56/36 56/36D.H.W. flow rate ∆T=35°C l/min 9.7 11.4D.H.W. flow rate ∆T=35°C gal/min 2.2 2.6D.H.W. minimum flow rate l/min 2.6 2.6Domestic hot water pressure max/min bar 8/0.2 8/0.2Built-in expansion vessel capacity l 6 6Built-in expansion vessel pre-charged pressure bar 1 1Maximum water content of system l 130 130Maximum heating pressure bar 3 3Gas inlet pressure - Natural Gas (G20) mbar 20 20Gas inlet pressure - LPG (G30-G31) mbar 30-37 30-37Weight Kg 34 35G.C. number 47-116-14 47-116-15

ELECTRICAL DATAElectrical supply V/Hz 230/50 230/50Power consumption W 140 155Protection grade of electrical system IP X4D X4DInternal fuse rating FAST 2 AT FAST 2 AT

C*: C12, C32, C42, C52, C82; (1):15°C, 1013 mbar*: Calculated at 70% maximum output

Flue connector

Air intake

Fan

Combustionchamber

hood

Main heatexchanger

Safetythermostat

Combustionchamber

Burner

Detection electrode

Ignition electrodes

Motorised diverter valve

Main circuit temperature probe

Domestic hot watertemperature

probe

Gas valve Spark generator

Water entry filter

Secondary heatexchanger

Main circuit flowswitch

Combustionanalysis intake

Air pressureswitch

Exhaust pressureintakes (venturi)

Expansion vessel

3 bar safety valve

Circulation pumpwith automatic airrelease valve

Page 8: microGENUS - The Initiativetheinitiativegroup.org.uk/fscinitiativedatabase/Ariston/microgenus_p… · Air intake Fan Combustion chamber hood Main heat exchanger Safety thermostat

FLUE PIPE ACCESSORIES - FOR ANY INSTALLATION, THE RIGHT PARTS FOR MAKING YOUR JOB EASIER

1

2

3

4

5

6 7

8

Ariston boilers offer the best choice because theyare all designed to be completely adaptable tothe many different situations that may beencountered on a daily basis. The need for alteration is almost completelyeliminated, allowing you to install the boiler in ashort time and with the utmost ease. This will also contribute towards the success ofyour business: an objective that has alwaysdistinguished the relationship between Aristonand its customers/partners.

A

BC

F

JD

HI

F

G

E

K

G

L

TERMINAL POSITION mmA Directly below an openable window or other opening 300B Below gutters, solid pipes or drain pipes 75C Below eaves 200D Below balconies or car-port roof 200E From vertical drain pipes and soil pipes 75F From internal or external corners 300G Above ground or below balcony level 300H From a surface facing a terminal 600I From a terminal facing a terminal 1200J From an opening in the car port

(e.g. door, window) into dwelling 1200K Vertically from a terminal in the same wall 1500L Horizontally from a terminal in the same wall 300

INSTALLATION CONDITIONS

Page 9: microGENUS - The Initiativetheinitiativegroup.org.uk/fscinitiativedatabase/Ariston/microgenus_p… · Air intake Fan Combustion chamber hood Main heat exchanger Safety thermostat

1

0

1

0

1

0

1

0

1

0

1

0

1

0

1

0

TYPE 1 Coaxial System

TYPE 5 Coaxial System TYPE 6 Twin pipe system TYPE 7 Twin pipe system

TYPE 2 Coaxial System TYPE 3 Coaxial System TYPE 4 Coaxial System

TYPE 8 Twin pipe system

Vertical exhaust / suction system withcoaxial piping on a flat roof.

Vertical exhaust / suction system withcoaxial piping on a pitched roof.

Horizontal exhaust / suction system withcoaxial piping.

Exhaust / suction system with 45°elbows, connected to an air / fume flueduct system.

Exhaust / suction system with a 90°elbow, connected to an air / fume flue system.

Coaxial system: up to 4 m

Twin pipe system up to 27 m

Exhaust / suction system with two separate pipes - exhaust on a pitchedroof, suction through a wall.

Exhaust / suction system with twoseparate pipes - exhaust and suction ona pitched roof via a coaxial adaptor.

Exhaust / suction system with two separate pipes - exhaust via flue duct,suction through a wall.

Page 10: microGENUS - The Initiativetheinitiativegroup.org.uk/fscinitiativedatabase/Ariston/microgenus_p… · Air intake Fan Combustion chamber hood Main heat exchanger Safety thermostat

ACCESSORIES AND SPARE PARTSENGINEERED FORPERFECT INSTALLATION

REAR-PIPING CHASSISAllows easy installation where thesystem pipes are required to run upthe rear of the boiler. The rear-piping chassis consists of abracket on which the boiler is hung,this has two flanks that extend theside panel of the boiler chassis.Assemble by just bringing forwardthe valve kit and connecting thepipes. The rear-piping chassis kit includesthe pipe work elements forconnection to the system.

MICROGENUS JIG-KITSupplied within the boiler as standardThe jig-kit makes installation easierbecause it allows you to fill the systemeven without the boiler fitted. It isequipped with 4 isolation valves: 2 forthe heating circuit, 2 for the domesticwater system. The system return isolation valve canbe connected to the system cleanerusing the plug provided. The bracketthat holds the valves can bepositioned in two ways depending onwhether installation is with or withoutthe rear-piping chassis, and allowssmall adjustments for irregular walls.

The kit is supplied with:• double non-return valves on the

filling loop for filling the system;• cold domestic water inlet with three

settings: summer, winter, and off;• “end-feed” connections on copper

tail pipes to ease soldering to thesystem piping.

SYSTEM CLEANERA practical accessory for cleaningthe heating system. It is simple to use: connect thesystem cleaner to the system returnisolation valve, open the systemreturn isolation valve, switch on theboiler, allow the pump to run for thenecessary time then remove thesystem cleaner from the kit.The filter provided is made up of aremovable cartridge which absorbsany impurities in the system. This allows the flushing of a newheating system without theimpurities damaging the boilercomponents. The system cleaner can also beused to add chemical additives suchas inhibitors.

Page 11: microGENUS - The Initiativetheinitiativegroup.org.uk/fscinitiativedatabase/Ariston/microgenus_p… · Air intake Fan Combustion chamber hood Main heat exchanger Safety thermostat

ANTI-THEFT DEVICEProtects the boiler from theft andcan be assembled in two ways: withor without the rear-piping chassis.The simple assembly instructionsare included in the jig-kit and on theanti-theft device itself.

JIG-KIT COVERTo conceal the pipe-work or jig-kitbelow the boiler a specially designedcover is available. The cover is simplyand easily mounted to the bottom ofthe boiler.

DIGITAL TIME CLOCK7 day timer.

PRINTED CIRCUIT BOARDRegulates the sophisticatedmanagement and control functions: • flame control• water control• overheating switch-off device• anti-frost safety device• anti-scale device• maximum heating power

adjustment• “soft-light” gas pressure

adjustment• combustion analysis device

Page 12: microGENUS - The Initiativetheinitiativegroup.org.uk/fscinitiativedatabase/Ariston/microgenus_p… · Air intake Fan Combustion chamber hood Main heat exchanger Safety thermostat

ARISTONQUALITY PRODUCTSEXCEPTIONAL SERVICE

• Belfast• Bristol• Edinburgh• High Wycombe• Manchester• Portsmouth• Rochester• Rotherham

COMPREHENSIVETRAINING

The numerous AristonTraining Centres allow you tolearn and expand your knowledge of the field.Courses cover areas such as customer relations, productselection, installation, system start-up, checks,maintenance, guarantees,and legislative standards.

TECHNICAL HOT LINE

Immediate and effectivetechnical assistance is onlya phone call away.Assistance is also availablefor any information or adviceon the product most suitablefor your needs and therequirements of your systeminstallation.

PROFESSIONALSERVICE

Ariston service technicians areswift and prepared for anyeventuality. They offer you andyour customers a high level ofassistance, comprising thebest technical, logistic andhuman resources available.Ariston invests a great deal inthis field to guarantee adecisive advantage that others cannot offer.

MTS (GB) LimitedMTS BuildingHughenden AvenueHigh WycombeBucks, HP13 5FTTel: 01494 755600Fax: 01494 459775

Technical Service Hot Line 01494 539579Technical Service Fax Line 01494 463066

E-mail: [email protected]

E-mail: [email protected]

In th

e in

tere

sts

of o

ur c

usto

mer

s, M

TS (G

B) L

imite

d is

con

tinua

lly d

evel

opin

g th

ese

prod

ucts

to im

prov

e bo

thpe

rfor

man

ce a

nd d

esig

n. W

e th

eref

ore

rese

rve

the

right

to c

hang

e sp

ecifi

catio

n w

ithou

t prio

r not

ice.

Thi

s br

ochu

re is

acc

urat

e at

the

date

of p

rintin

g. C

onsu

mer

sta

tuto

ry ri

ghts

are

not

aff

ecte

d.

0063

Mon

th &

Yea

r Prin

ted

by V

ario

Pre

ss