MicroMicro Hydro Power in Hydro Power in WNCWNC
Oct 27, 2007Oct 27, 2007Andrews, NCAndrews, NC
![Page 2: Micro Hydro Power in WNC Oct 27, 2007 Andrews, NC](https://reader035.vdocuments.mx/reader035/viewer/2022062221/56649d935503460f94a79a67/html5/thumbnails/2.jpg)
Hydro, Driven by Solar PowerHydro, Driven by Solar Power
![Page 3: Micro Hydro Power in WNC Oct 27, 2007 Andrews, NC](https://reader035.vdocuments.mx/reader035/viewer/2022062221/56649d935503460f94a79a67/html5/thumbnails/3.jpg)
Existing hydroelectric plants (yellow) and potential high head/low power energy sites (orange) in the conterminous United States. Purple represents areas excluded from hydropower development due to Federal statutes and policies.
Source: Water Energy Resources of the United States with Emphasis on Low Head/Low Power Resources (p. 47), U.S. Department of Energy
![Page 4: Micro Hydro Power in WNC Oct 27, 2007 Andrews, NC](https://reader035.vdocuments.mx/reader035/viewer/2022062221/56649d935503460f94a79a67/html5/thumbnails/4.jpg)
Hydro power in USA, Canada and the WorldHydro power in USA, Canada and the World
US Supply
![Page 5: Micro Hydro Power in WNC Oct 27, 2007 Andrews, NC](https://reader035.vdocuments.mx/reader035/viewer/2022062221/56649d935503460f94a79a67/html5/thumbnails/5.jpg)
Most of that global hydro power is produced by large-scale hydroelectric plants
![Page 6: Micro Hydro Power in WNC Oct 27, 2007 Andrews, NC](https://reader035.vdocuments.mx/reader035/viewer/2022062221/56649d935503460f94a79a67/html5/thumbnails/6.jpg)
Today, we will be talking about
microhydro•Small in scale
•Minimum environmental impact
•Site specific: you must have the resource
•Affordable.
•Consistent: Produces continuously, 24/7
![Page 7: Micro Hydro Power in WNC Oct 27, 2007 Andrews, NC](https://reader035.vdocuments.mx/reader035/viewer/2022062221/56649d935503460f94a79a67/html5/thumbnails/7.jpg)
We don’t need a river, just some falling water
![Page 8: Micro Hydro Power in WNC Oct 27, 2007 Andrews, NC](https://reader035.vdocuments.mx/reader035/viewer/2022062221/56649d935503460f94a79a67/html5/thumbnails/8.jpg)
Types of SystemsTypes of Systems
Turbines can be of many forms. Turbines can be of many forms.
Listed are a few of the major types.Listed are a few of the major types.
High head Medium head Low head
Impulse turbines Pelton Turgo
cross-flow multi-jet Pelton Turgo
cross-flow
Reaction turbines
Francis
Pump-as-turbine
(PAT)
propeller Kaplan
![Page 9: Micro Hydro Power in WNC Oct 27, 2007 Andrews, NC](https://reader035.vdocuments.mx/reader035/viewer/2022062221/56649d935503460f94a79a67/html5/thumbnails/9.jpg)
Pelton and TurgoImpulse – jet of water
4 “
![Page 10: Micro Hydro Power in WNC Oct 27, 2007 Andrews, NC](https://reader035.vdocuments.mx/reader035/viewer/2022062221/56649d935503460f94a79a67/html5/thumbnails/10.jpg)
Banki
Crossflow
Banki and CrossflowImpulse – sheet of water
![Page 11: Micro Hydro Power in WNC Oct 27, 2007 Andrews, NC](https://reader035.vdocuments.mx/reader035/viewer/2022062221/56649d935503460f94a79a67/html5/thumbnails/11.jpg)
http://www.toshiba.co.jp/f-ene/hydro/english/products/equipment/index01_2.htm
Kaplan
http://www.waterwheelfactory.com/francis.htm
FrancisReaction Turbines
Submerged in the flow; driven by the pressure differential
![Page 12: Micro Hydro Power in WNC Oct 27, 2007 Andrews, NC](https://reader035.vdocuments.mx/reader035/viewer/2022062221/56649d935503460f94a79a67/html5/thumbnails/12.jpg)
Turbines are turned by water.
That turning motion drives a generator which produced electricity.
![Page 13: Micro Hydro Power in WNC Oct 27, 2007 Andrews, NC](https://reader035.vdocuments.mx/reader035/viewer/2022062221/56649d935503460f94a79a67/html5/thumbnails/13.jpg)
You need two things to make power
Head and Flow
![Page 14: Micro Hydro Power in WNC Oct 27, 2007 Andrews, NC](https://reader035.vdocuments.mx/reader035/viewer/2022062221/56649d935503460f94a79a67/html5/thumbnails/14.jpg)
Power Estimates
![Page 15: Micro Hydro Power in WNC Oct 27, 2007 Andrews, NC](https://reader035.vdocuments.mx/reader035/viewer/2022062221/56649d935503460f94a79a67/html5/thumbnails/15.jpg)
Gross Power Calculations
Power (watts) = Head (ft) * Flow (GPM)
10
The equation assumes a turbine efficiency of 53%. Actual efficiency varies with conditions.
Power output is proportional to the combination of head and flow
![Page 16: Micro Hydro Power in WNC Oct 27, 2007 Andrews, NC](https://reader035.vdocuments.mx/reader035/viewer/2022062221/56649d935503460f94a79a67/html5/thumbnails/16.jpg)
Examples
Turtle Island Mollies Branch
![Page 17: Micro Hydro Power in WNC Oct 27, 2007 Andrews, NC](https://reader035.vdocuments.mx/reader035/viewer/2022062221/56649d935503460f94a79a67/html5/thumbnails/17.jpg)
Turtle Island
Stream flow = 300 GPM(1/2 of flow is 150 GPM)Total Head is 140 feet
Gross Power Estimate = (140 ft * 150 GPM)/10= 2100 W
![Page 18: Micro Hydro Power in WNC Oct 27, 2007 Andrews, NC](https://reader035.vdocuments.mx/reader035/viewer/2022062221/56649d935503460f94a79a67/html5/thumbnails/18.jpg)
Mollies Branch
Mollies Branch has a flow of 300 GPM
(1/2 of flow is 150 GPM)
Total Head is 110 feet
Gross Power Estimate =
(110 ft * 150 GPM)/10= 1650 W
![Page 19: Micro Hydro Power in WNC Oct 27, 2007 Andrews, NC](https://reader035.vdocuments.mx/reader035/viewer/2022062221/56649d935503460f94a79a67/html5/thumbnails/19.jpg)
Why is this gross power?
These are not accurate calculations because we used the gross or static head instead of the net or dynamic head.
A more accurate power calculation is made after calculating pipe friction losses.
Stay tuned................
![Page 20: Micro Hydro Power in WNC Oct 27, 2007 Andrews, NC](https://reader035.vdocuments.mx/reader035/viewer/2022062221/56649d935503460f94a79a67/html5/thumbnails/20.jpg)
...or Charts from ManufacturerP.M. Alternator output in watts
FEET OF NET HEAD
GAL/M 25 50 75 100 200 300
3 - - - - 45 80
6 - - 30 45 130 180
10 - 40 75 95 210 300
15 25 75 110 150 320 450
20 40 100 160 240 480 600
30 65 150 250 350 650 940
50 130 265 420 600 1100 1500
100 230 500 750 1100 1500 -
200 - 580 900 1300 - -
![Page 21: Micro Hydro Power in WNC Oct 27, 2007 Andrews, NC](https://reader035.vdocuments.mx/reader035/viewer/2022062221/56649d935503460f94a79a67/html5/thumbnails/21.jpg)
Measuring Head
![Page 22: Micro Hydro Power in WNC Oct 27, 2007 Andrews, NC](https://reader035.vdocuments.mx/reader035/viewer/2022062221/56649d935503460f94a79a67/html5/thumbnails/22.jpg)
Measuring Head
5’ stick with carpenters level Sight level Water level Pipe with pressure gauge GPS Unit Transit Topo map Altimeter
![Page 23: Micro Hydro Power in WNC Oct 27, 2007 Andrews, NC](https://reader035.vdocuments.mx/reader035/viewer/2022062221/56649d935503460f94a79a67/html5/thumbnails/23.jpg)
Measuring Head
5’ stick with level (3 people)
5’
![Page 24: Micro Hydro Power in WNC Oct 27, 2007 Andrews, NC](https://reader035.vdocuments.mx/reader035/viewer/2022062221/56649d935503460f94a79a67/html5/thumbnails/24.jpg)
Measuring Head
Sight level (2 people)
Eye level
![Page 25: Micro Hydro Power in WNC Oct 27, 2007 Andrews, NC](https://reader035.vdocuments.mx/reader035/viewer/2022062221/56649d935503460f94a79a67/html5/thumbnails/25.jpg)
Remember, you don’t have to follow the creek.
![Page 26: Micro Hydro Power in WNC Oct 27, 2007 Andrews, NC](https://reader035.vdocuments.mx/reader035/viewer/2022062221/56649d935503460f94a79a67/html5/thumbnails/26.jpg)
Measuring HeadWater level and measuring tape (2 people)
Water level
![Page 27: Micro Hydro Power in WNC Oct 27, 2007 Andrews, NC](https://reader035.vdocuments.mx/reader035/viewer/2022062221/56649d935503460f94a79a67/html5/thumbnails/27.jpg)
Measuring Head Transit Most accurate if you have the equipment
![Page 28: Micro Hydro Power in WNC Oct 27, 2007 Andrews, NC](https://reader035.vdocuments.mx/reader035/viewer/2022062221/56649d935503460f94a79a67/html5/thumbnails/28.jpg)
Measuring Head
Pipe with pressure gauge at the bottom
Could use garden hose(s)
2.31 feet = 1 psi This gauge reads 38 psi 38 psi x 2.31 feet/psi = 88 ft
of static head
![Page 29: Micro Hydro Power in WNC Oct 27, 2007 Andrews, NC](https://reader035.vdocuments.mx/reader035/viewer/2022062221/56649d935503460f94a79a67/html5/thumbnails/29.jpg)
Measuring Head
GPS, altimeter, topo map
Difference in elevation readings
![Page 30: Micro Hydro Power in WNC Oct 27, 2007 Andrews, NC](https://reader035.vdocuments.mx/reader035/viewer/2022062221/56649d935503460f94a79a67/html5/thumbnails/30.jpg)
Measuring Flow
![Page 31: Micro Hydro Power in WNC Oct 27, 2007 Andrews, NC](https://reader035.vdocuments.mx/reader035/viewer/2022062221/56649d935503460f94a79a67/html5/thumbnails/31.jpg)
Measuring Flow
Units GPM: gallons per minute CFM: cubic feet per minute CFS: cubic feet per second
How much to use? Don’t take the whole creek! Use minimum flow Avoid taking more than ½ of the flow
Water temp could be effected!!! Let the ecosystem thrive
![Page 32: Micro Hydro Power in WNC Oct 27, 2007 Andrews, NC](https://reader035.vdocuments.mx/reader035/viewer/2022062221/56649d935503460f94a79a67/html5/thumbnails/32.jpg)
Methods of Flow Assessment
5-gallon bucketSmall stream, small waterfall
Float methodLarger, flat, uniform stream
V-notch Weir Rectangular Weir Make several measurements to assess
seasonal variation
![Page 33: Micro Hydro Power in WNC Oct 27, 2007 Andrews, NC](https://reader035.vdocuments.mx/reader035/viewer/2022062221/56649d935503460f94a79a67/html5/thumbnails/33.jpg)
5 gallon bucket
![Page 34: Micro Hydro Power in WNC Oct 27, 2007 Andrews, NC](https://reader035.vdocuments.mx/reader035/viewer/2022062221/56649d935503460f94a79a67/html5/thumbnails/34.jpg)
5 gallon bucket
If the measured flow using a 5 gallon bucket and a stop watch was 5 gallons in 1.5 seconds, how many GPM would this be?
![Page 35: Micro Hydro Power in WNC Oct 27, 2007 Andrews, NC](https://reader035.vdocuments.mx/reader035/viewer/2022062221/56649d935503460f94a79a67/html5/thumbnails/35.jpg)
5 gallon bucket
If the measured flow using a 5 gallon bucket and a stop watch was 5 gallons in 1.5 seconds, how many GPM would this be?
GPMgal
200min1
sec60
sec5.1
5
![Page 36: Micro Hydro Power in WNC Oct 27, 2007 Andrews, NC](https://reader035.vdocuments.mx/reader035/viewer/2022062221/56649d935503460f94a79a67/html5/thumbnails/36.jpg)
Float methodBig, flat, uniform creek
![Page 37: Micro Hydro Power in WNC Oct 27, 2007 Andrews, NC](https://reader035.vdocuments.mx/reader035/viewer/2022062221/56649d935503460f94a79a67/html5/thumbnails/37.jpg)
Float methodFlow (ft3/s) = Velocity (ft/s) x Cross Sectional Area (ft2)
![Page 38: Micro Hydro Power in WNC Oct 27, 2007 Andrews, NC](https://reader035.vdocuments.mx/reader035/viewer/2022062221/56649d935503460f94a79a67/html5/thumbnails/38.jpg)
Float method
1. Calculate the average depth
Lay a board across the stream, measure the depth every foot, average the depths
![Page 39: Micro Hydro Power in WNC Oct 27, 2007 Andrews, NC](https://reader035.vdocuments.mx/reader035/viewer/2022062221/56649d935503460f94a79a67/html5/thumbnails/39.jpg)
Float method
2. Calculate the cross sectional area
Area (ft2) = Average depth (ft) x Width (ft)
![Page 40: Micro Hydro Power in WNC Oct 27, 2007 Andrews, NC](https://reader035.vdocuments.mx/reader035/viewer/2022062221/56649d935503460f94a79a67/html5/thumbnails/40.jpg)
Float method
3. Calculate velocity
Measure where you measured the area, an orange makes a good float, start well upstream, a 10’ span is good, average multiple measurements
![Page 41: Micro Hydro Power in WNC Oct 27, 2007 Andrews, NC](https://reader035.vdocuments.mx/reader035/viewer/2022062221/56649d935503460f94a79a67/html5/thumbnails/41.jpg)
Float method
4. Correct for Friction
Flow (ft3/s) = Velocity (ft/s) x Cross Sectional Area (ft3) x .83
Multiply x 0.830.83 to correct for friction on the bottom of the stream
![Page 42: Micro Hydro Power in WNC Oct 27, 2007 Andrews, NC](https://reader035.vdocuments.mx/reader035/viewer/2022062221/56649d935503460f94a79a67/html5/thumbnails/42.jpg)
Float MethodSo, if these guys measure this 3’ wide
stream and get an average depth of 8” and it takes an orange an average 5 seconds to go 10 feet, what is the flow in GPM?
•Area = 3’ x 8” x (1’/12”) = 2 ft2
•Velocity = 10 ft/5 s = 2 ft/s
•Flow = 2 ft2 x 2 ft/ s = 4 ft3/s
•4 ft3/s x 7.48 gal/1 ft3 x 60s/1 min = 1795 gpm
•Correct for friction, 1795 gpm x .83 = 1490 gpm
![Page 43: Micro Hydro Power in WNC Oct 27, 2007 Andrews, NC](https://reader035.vdocuments.mx/reader035/viewer/2022062221/56649d935503460f94a79a67/html5/thumbnails/43.jpg)
Weir Method
For larger flows or more accurate measurements
Small V-notch
Larger Rectangular
All you needs is depth and the table
![Page 44: Micro Hydro Power in WNC Oct 27, 2007 Andrews, NC](https://reader035.vdocuments.mx/reader035/viewer/2022062221/56649d935503460f94a79a67/html5/thumbnails/44.jpg)
V-notch Weir
![Page 45: Micro Hydro Power in WNC Oct 27, 2007 Andrews, NC](https://reader035.vdocuments.mx/reader035/viewer/2022062221/56649d935503460f94a79a67/html5/thumbnails/45.jpg)
Rectangular Weir
![Page 46: Micro Hydro Power in WNC Oct 27, 2007 Andrews, NC](https://reader035.vdocuments.mx/reader035/viewer/2022062221/56649d935503460f94a79a67/html5/thumbnails/46.jpg)
“the pipe”
PenstockPenstock
![Page 47: Micro Hydro Power in WNC Oct 27, 2007 Andrews, NC](https://reader035.vdocuments.mx/reader035/viewer/2022062221/56649d935503460f94a79a67/html5/thumbnails/47.jpg)
The IntakeDiverting clean water into the penstock
Screen
Start of Penstock
Steam Flow
The intake’s job:
Filter and Settle
Build it either:Simple and easy
to repairOr
Bullet-proof
![Page 48: Micro Hydro Power in WNC Oct 27, 2007 Andrews, NC](https://reader035.vdocuments.mx/reader035/viewer/2022062221/56649d935503460f94a79a67/html5/thumbnails/48.jpg)
The IntakeDiverting clean water into the penstock
Screen Start of Penstock
Steam Flow
A dirty creek
may need more
settling time
Overflow
![Page 49: Micro Hydro Power in WNC Oct 27, 2007 Andrews, NC](https://reader035.vdocuments.mx/reader035/viewer/2022062221/56649d935503460f94a79a67/html5/thumbnails/49.jpg)
PenstockA full pipe; delivering clean water to the turbine
![Page 50: Micro Hydro Power in WNC Oct 27, 2007 Andrews, NC](https://reader035.vdocuments.mx/reader035/viewer/2022062221/56649d935503460f94a79a67/html5/thumbnails/50.jpg)
Pipe can be a Considerable Cost…up to 40%
![Page 51: Micro Hydro Power in WNC Oct 27, 2007 Andrews, NC](https://reader035.vdocuments.mx/reader035/viewer/2022062221/56649d935503460f94a79a67/html5/thumbnails/51.jpg)
Factors to Consider: Penstock
surface roughness design pressure method of jointing weight and ease of installation accessibility of the site terrain design life and maintenance weather conditions availability relative cost likelihood of structural damage
![Page 52: Micro Hydro Power in WNC Oct 27, 2007 Andrews, NC](https://reader035.vdocuments.mx/reader035/viewer/2022062221/56649d935503460f94a79a67/html5/thumbnails/52.jpg)
Burying Pipe
Burying a pipe line removes the biggest eyesore of a hydro scheme.
It is vital to ensure a buried penstock is properly and meticulously installed subsequent problems such
as leaks are much harder to detect and rectify.
![Page 53: Micro Hydro Power in WNC Oct 27, 2007 Andrews, NC](https://reader035.vdocuments.mx/reader035/viewer/2022062221/56649d935503460f94a79a67/html5/thumbnails/53.jpg)
Penstock Support SystemPVC likes to stay straight
HDPE can follow the contour of the ground
![Page 54: Micro Hydro Power in WNC Oct 27, 2007 Andrews, NC](https://reader035.vdocuments.mx/reader035/viewer/2022062221/56649d935503460f94a79a67/html5/thumbnails/54.jpg)
Pipe Friction Losses
Must use charts to calculate head loss due to pipe friction
Flow varies with D3
4” pipe can flow 8x more water than 2” pipe
![Page 55: Micro Hydro Power in WNC Oct 27, 2007 Andrews, NC](https://reader035.vdocuments.mx/reader035/viewer/2022062221/56649d935503460f94a79a67/html5/thumbnails/55.jpg)
Lets do an example
Turtle Island 140 ft static head Pipe = 3” HDPE (High Density Poly Ethylene)
What is friction loss for 1300’ pipe for a flow of 100 GPM?
What is the dynamic or net head?
![Page 56: Micro Hydro Power in WNC Oct 27, 2007 Andrews, NC](https://reader035.vdocuments.mx/reader035/viewer/2022062221/56649d935503460f94a79a67/html5/thumbnails/56.jpg)
Lets do an example:PIPE FRICTION LOSS
Polyethylene SDR - Pressure Rated Pipe
Pressure Loss from Friction in Feet of Head per 100 Feet of Pipe
Flow US GPM
0.5 0.75 1 1.25 1.5 2 2.5 3
1 1.13 0.28 0.09 0.02
2 4.05 1.04 0.32 0.09 0.04
3 8.6 2.19 0.67 0.19 0.09 0.02
4 14.6 3.73 1.15 0.3 0.14 0.05
5 22.1 5.61 1.75 0.46 0.21 0.07
90 13.5 5.71 1.98
95 15 6.31 2.19
100 16.5 6.92 2.42
150 34.5 14.7 5.11
200 25 8.7
300 18.4
![Page 57: Micro Hydro Power in WNC Oct 27, 2007 Andrews, NC](https://reader035.vdocuments.mx/reader035/viewer/2022062221/56649d935503460f94a79a67/html5/thumbnails/57.jpg)
Lets do an example
Turtle Island 140 ft head 3” HDPE (High Density Poly Ethylene) What is friction loss for 1300’ pipe for a flow of 100 GPM? What is the dynamic head?
Chart says we’ll lose 2.42’ of head per 100’ of pipe.
We have 13 x 100’ of pipe, so 13 x 2.42’ = 31.5’ of total head loss
Dynamic or Dynamic or net headnet head = 140’ – 31.5’ = = 140’ – 31.5’ = 108.5’108.5’
![Page 58: Micro Hydro Power in WNC Oct 27, 2007 Andrews, NC](https://reader035.vdocuments.mx/reader035/viewer/2022062221/56649d935503460f94a79a67/html5/thumbnails/58.jpg)
Nozzles
![Page 59: Micro Hydro Power in WNC Oct 27, 2007 Andrews, NC](https://reader035.vdocuments.mx/reader035/viewer/2022062221/56649d935503460f94a79a67/html5/thumbnails/59.jpg)
Nozzles
The flowrate from the penstock is controlled by properly sizing the nozzle(s) at the turbine.
![Page 60: Micro Hydro Power in WNC Oct 27, 2007 Andrews, NC](https://reader035.vdocuments.mx/reader035/viewer/2022062221/56649d935503460f94a79a67/html5/thumbnails/60.jpg)
Nozzles
What size nozzles and how many would you recommend if one wants to use about ½ of a stream with 300 GPM of measured flow with 100 ft of head (pelton wheel)?
![Page 61: Micro Hydro Power in WNC Oct 27, 2007 Andrews, NC](https://reader035.vdocuments.mx/reader035/viewer/2022062221/56649d935503460f94a79a67/html5/thumbnails/61.jpg)
Nozzles
Maximum efficient flow at various heads
From Harris Hydro(FIGURES IN GALLONS/MIN)
FEET OF NET HEAD
# of nozzles 25 50 75 100 200 300
1 17 25 30 35 50 60
2 35 50 60 70 100 120
3 52 75 90 105 150 -
4 70 100 120 140 200 -
![Page 62: Micro Hydro Power in WNC Oct 27, 2007 Andrews, NC](https://reader035.vdocuments.mx/reader035/viewer/2022062221/56649d935503460f94a79a67/html5/thumbnails/62.jpg)
NozzlesNOZZLE FLOW CHART – from ES & D
FLOW RATE IN U.S. GALLONS PER MINUTE
Head Feet
PSI Nozzle Diameter, inches RPM
1/8 3/16 1/4 5/16 3/8 7/16 1/2 5/8 3/4 7/8 1
5 2.2 6.18 8.4 11 17.1 24.7 33.6 43.9 460
10 4.3 3.88 6.05 8.75 11.6 15.6 24.2 35 47.6 62.1 650
15 6.5 2.68 4.76 7.4 10.7 14.6 19 29.7 42.8 58.2 76 800
20 8.7 1.37 3.09 5.49 8.56 12.4 16.8 22 34.3 49.4 67.3 87.8 925
30 13 1.68 3.78 6.72 10.5 15.1 20.6 26.9 42 60.5 82.4 107 1140
40 17.3 1.94 4.37 7.76 12.1 17.5 23.8 31.1 48.5 69.9 95.1 124 1310
50 21.7 2.17 4.88 8.68 13.6 19.5 26.6 34.7 54.3 78.1 106 139 1470
60 26 2.38 5.35 9.51 14.8 21.4 29.1 38 59.4 85.6 117 152 1600
80 34.6 2.75 6.18 11 17.1 24.7 33.6 43.9 68.6 98.8 135 176 1850
100 43.3 3.07 6.91 12.3 19.2 27.6 37.6 49.1 76.7 111 150 196 2070
120 52 3.36 7.56 13.4 21 30.3 41.2 53.8 84.1 121 165 215 2270
150 65 3.76 8.95 15 23.5 33.8 46 60.1 93.9 135 184 241 2540
200 86.6 4.34 9.77 17.4 27.1 39.1 53.2 69.4 109 156 213 278 2930
250 108 4.86 10.9 19.9 30.3 43.6 59.4 77.6 121 175 238 311 3270
300 130 5.32 12 21.3 33.2 47.8 65.1 85.1 133 191 261 340 3591
400 173 6.14 13.8 24.5 38.3 55.2 75.2 98.2 154 221 301 393 4140
300 gpm/2 = 150 gpm usable flow
150 gpm/4 = 37.5 gpm per nozzle
(4) 7/16” nozzles should do it(4) 7/16” nozzles should do it
![Page 63: Micro Hydro Power in WNC Oct 27, 2007 Andrews, NC](https://reader035.vdocuments.mx/reader035/viewer/2022062221/56649d935503460f94a79a67/html5/thumbnails/63.jpg)
Micro Turbines
![Page 64: Micro Hydro Power in WNC Oct 27, 2007 Andrews, NC](https://reader035.vdocuments.mx/reader035/viewer/2022062221/56649d935503460f94a79a67/html5/thumbnails/64.jpg)
Harris Hydro Efficient, durable, battery
charging pelton turbine with an adjustable permanent magnet generator.
20-600 feet of head 2-250 GPM of flow
1 nozzle $1800 2 nozzle $1950 4 nozzle $2150
![Page 65: Micro Hydro Power in WNC Oct 27, 2007 Andrews, NC](https://reader035.vdocuments.mx/reader035/viewer/2022062221/56649d935503460f94a79a67/html5/thumbnails/65.jpg)
Energy Systems & Design Stream Engine Brushless, permanent magnet
alternator which is adjustable Capable of outputs over 1 kilowatt Heads from 6 to 300 feet. Equipped with a rugged bronze turgo
wheel, universal nozzles (adaptable to sizing from 1/8 to1 inch), and a digital multimeter which is used to measure output current.
www.microhydropower.com
2 Nozzle Bronze $23954 Nozzle Bronze $2545High Voltage Option $200 High Current Option $100
![Page 66: Micro Hydro Power in WNC Oct 27, 2007 Andrews, NC](https://reader035.vdocuments.mx/reader035/viewer/2022062221/56649d935503460f94a79a67/html5/thumbnails/66.jpg)
Energy Systems & Design Low Head Propeller Turbine Uses the same generator as the
Stream Engine, however the water turbine component uses a low head propeller design.
heads of 2 feet up to 10 feet. At the maximum head, the output
is 1 kW.
www.microhydropower.com
Water Baby Operates much the same as the
Stream Engine but requires very little water (pelton wheel)
Will operate on as little as 3 gpm but requires at least 100 feet of head.
At a head of 100 feet and a flow of 3 gpm the output is 25 watts; at 24 gpm the output is 250 watts.
Baby Generator, 1 Nozzle(12/24 volt)
$1395
Extra Nozzles (installed) $120 ea
High Voltage (48/120 volt) $100
LH1000 with Draft Tube $1995
High Voltage Option $200 extra
High Current Option $100 extra
![Page 67: Micro Hydro Power in WNC Oct 27, 2007 Andrews, NC](https://reader035.vdocuments.mx/reader035/viewer/2022062221/56649d935503460f94a79a67/html5/thumbnails/67.jpg)
Hydro Induction Power
Good for long wire runs, 60' - 500' head, 10 - 600 gpm
The units produce 3-Phase 120V, 240V, or 480V 'wild' (unregulated) AC, which is then stepped down to battery voltage.
The heavy-duty brushless alternator is housed on the Harris Housing
Uses the Harris bronze Pelton Wheel for flows up to 200 gpm and the bronze Turgo Runner for flows of 200 to 600 gpm.
www.hipowerhydro.com
HV 600 with 2 Nozzles $2500 HV 600 with 4 Nozzles $2600 HV 1200 with 4 Nozzles $3000 HV 1800 with 4 Nozzles $3500 HV 3600 with 4 Nozzles $5000 Turgo option $600
![Page 68: Micro Hydro Power in WNC Oct 27, 2007 Andrews, NC](https://reader035.vdocuments.mx/reader035/viewer/2022062221/56649d935503460f94a79a67/html5/thumbnails/68.jpg)
Hydro Induction Power
Now offer a new LOW VOLTAGE (12V/24V), brushless unit (48V coming in 2006).
It can generate either 12V or 24V with pressures from 20psi to 150psi (46' - 400'). Above this pressure, it will generate 48V.
Lots of accessories
www.homehydro.com
12/24V Hydro with 1 Nozzle: $1350
12/24V Hydro with 2 Nozzles:$1400
12/24V Hydro with 3 Nozzles:$1450
12/24V Hydro with 4 Nozzles:$1500
Upgrade from Harris Hydro: $500 Turgo option $600
![Page 69: Micro Hydro Power in WNC Oct 27, 2007 Andrews, NC](https://reader035.vdocuments.mx/reader035/viewer/2022062221/56649d935503460f94a79a67/html5/thumbnails/69.jpg)
Powerpal
Low head model A simple AC single-phase, brushless
permanent magnet alternator is attached to a propeller turbine.
Electricity passes along a wire and into a house, where an electronic load controller stabilizes the voltage to 110V or 220V to protect electrical appliances during use.
Many models available (see chart, next slide)
www.powerpal.com
MHG-200LH MHG-500LH MHG-1000LH
Water head (ft) 4.92 4.92 4.92
Water flow (gpm) 555 1110 2061
Output Power 200W 500W 1000W
The 200 watt unit needs 550 gallons per minute
![Page 70: Micro Hydro Power in WNC Oct 27, 2007 Andrews, NC](https://reader035.vdocuments.mx/reader035/viewer/2022062221/56649d935503460f94a79a67/html5/thumbnails/70.jpg)
Powerpal High head model The Same AC single-phase,
brushless PMt alternator that is used for the Low Head Series is used here and attached to a Turgo Turbine.
Also comes with an electronic load controller (ELC)
www.powerpal.com
MHG-200HH
MHG-500HH
Water head (ft) 16.4 19.68 22.96 26.24 29.52 32.8 36.08
Water flow (gpm) 100 101 117 125 133 141 144
Output Power 160w 200w 275w 325w 390w 460w 520w
![Page 71: Micro Hydro Power in WNC Oct 27, 2007 Andrews, NC](https://reader035.vdocuments.mx/reader035/viewer/2022062221/56649d935503460f94a79a67/html5/thumbnails/71.jpg)
Canyon Hydro
Serious engineering
1854084
1013335
362415
121665
KWgpm
Canyon 2435
15340
8277
3197
1139
KWgpm
Canyon 751
300
200
100
50
100 KW Canyon Crossflow
www.canyonhydro.com
![Page 72: Micro Hydro Power in WNC Oct 27, 2007 Andrews, NC](https://reader035.vdocuments.mx/reader035/viewer/2022062221/56649d935503460f94a79a67/html5/thumbnails/72.jpg)
Alternative Power & Machine
Economy models Permanent magnet units Accessories Exercise Bicycle Type Battery
Chargers, etc. Niche: Ease of maintenance
and adjustment
www.apmhydro.com
![Page 73: Micro Hydro Power in WNC Oct 27, 2007 Andrews, NC](https://reader035.vdocuments.mx/reader035/viewer/2022062221/56649d935503460f94a79a67/html5/thumbnails/73.jpg)
Make your own
www.otherpower.com
![Page 74: Micro Hydro Power in WNC Oct 27, 2007 Andrews, NC](https://reader035.vdocuments.mx/reader035/viewer/2022062221/56649d935503460f94a79a67/html5/thumbnails/74.jpg)
Otherwww.ampair.com....it’s a wind and hydro turbine $1300
The Jack Rabbit, just drop it into the river
$1295www.bali-i.com/hydro/jackrabbit-prod.htm
![Page 75: Micro Hydro Power in WNC Oct 27, 2007 Andrews, NC](https://reader035.vdocuments.mx/reader035/viewer/2022062221/56649d935503460f94a79a67/html5/thumbnails/75.jpg)
Turbine Housing
Many options. Main point: allow the water to fall away from the turbine runner and not bounce back onto the runner
and to divert the water back to the stream.
![Page 76: Micro Hydro Power in WNC Oct 27, 2007 Andrews, NC](https://reader035.vdocuments.mx/reader035/viewer/2022062221/56649d935503460f94a79a67/html5/thumbnails/76.jpg)
BOS…….Balance of System
![Page 77: Micro Hydro Power in WNC Oct 27, 2007 Andrews, NC](https://reader035.vdocuments.mx/reader035/viewer/2022062221/56649d935503460f94a79a67/html5/thumbnails/77.jpg)
What is the BOS? DC only system (small
cabin) Charge controller Batteries
Conventional AC system (house) Charge controller Batteries Inverter
![Page 78: Micro Hydro Power in WNC Oct 27, 2007 Andrews, NC](https://reader035.vdocuments.mx/reader035/viewer/2022062221/56649d935503460f94a79a67/html5/thumbnails/78.jpg)
Model List Price ($US)
C35 $119.00
C40 $159.00
C60 $199.00
ie. Xantrex “C” Series Charge Controller•12, 24, 48 VDC•automatically directs extra power to a dedicated load such as an electric water heater and ensures batteries are never over-charged.
Model # is rated DC current
www.xantrex.com
![Page 79: Micro Hydro Power in WNC Oct 27, 2007 Andrews, NC](https://reader035.vdocuments.mx/reader035/viewer/2022062221/56649d935503460f94a79a67/html5/thumbnails/79.jpg)
Diversion Load, aka Dump Load
Usually a resistive load like a heater At least as large as the full turbine
output and within the current limit of the charge controller
Small hydro system = small amounts of heat
Use waste heat for water heating, air heating…
Usually not enough heat for domestic use (1kW = 3412 BTU)
Head lights as dump load for wind turbine
![Page 80: Micro Hydro Power in WNC Oct 27, 2007 Andrews, NC](https://reader035.vdocuments.mx/reader035/viewer/2022062221/56649d935503460f94a79a67/html5/thumbnails/80.jpg)
Outback Inverters
![Page 81: Micro Hydro Power in WNC Oct 27, 2007 Andrews, NC](https://reader035.vdocuments.mx/reader035/viewer/2022062221/56649d935503460f94a79a67/html5/thumbnails/81.jpg)
Xantrex Inverters
![Page 82: Micro Hydro Power in WNC Oct 27, 2007 Andrews, NC](https://reader035.vdocuments.mx/reader035/viewer/2022062221/56649d935503460f94a79a67/html5/thumbnails/82.jpg)
Batteryless Grid-Tie Options
Systems available for PV and wind Still a special system for Microhydro Contact Hydro Induction Power
www.hipowerhydro.com
![Page 83: Micro Hydro Power in WNC Oct 27, 2007 Andrews, NC](https://reader035.vdocuments.mx/reader035/viewer/2022062221/56649d935503460f94a79a67/html5/thumbnails/83.jpg)
AC Systems Larger systems can be
AC, no battery If the continuous output of
a system is high enough to meet your needs for surging capacity, no battery/inverter subsystem is required, and AC can be generated directly.
![Page 84: Micro Hydro Power in WNC Oct 27, 2007 Andrews, NC](https://reader035.vdocuments.mx/reader035/viewer/2022062221/56649d935503460f94a79a67/html5/thumbnails/84.jpg)
Storing Renewable Energy: Batteries
“Chemical engines used to push electrons around”
![Page 85: Micro Hydro Power in WNC Oct 27, 2007 Andrews, NC](https://reader035.vdocuments.mx/reader035/viewer/2022062221/56649d935503460f94a79a67/html5/thumbnails/85.jpg)
Battery Bank Sizing
A battery based alternative energy system will not be effective if it is not
sized correctly
![Page 86: Micro Hydro Power in WNC Oct 27, 2007 Andrews, NC](https://reader035.vdocuments.mx/reader035/viewer/2022062221/56649d935503460f94a79a67/html5/thumbnails/86.jpg)
Battery Bank Sizing
Battery storage for PV and Wind systems typically require 3 or more days of battery storage
Hydro systems run all the time Batteries in a hydro system typically need to
store energy for less than a day Often, the battery is sized to provide
sufficient current to the inverter rather than an amount of storage
![Page 87: Micro Hydro Power in WNC Oct 27, 2007 Andrews, NC](https://reader035.vdocuments.mx/reader035/viewer/2022062221/56649d935503460f94a79a67/html5/thumbnails/87.jpg)
Life Expectancy and cost
At least 5 years Often over 10 years or
1500 deep cycles Shipping is expensive Cost is about $200 per
6V battery
![Page 88: Micro Hydro Power in WNC Oct 27, 2007 Andrews, NC](https://reader035.vdocuments.mx/reader035/viewer/2022062221/56649d935503460f94a79a67/html5/thumbnails/88.jpg)
Rest Voltage vs. State of Charge
![Page 89: Micro Hydro Power in WNC Oct 27, 2007 Andrews, NC](https://reader035.vdocuments.mx/reader035/viewer/2022062221/56649d935503460f94a79a67/html5/thumbnails/89.jpg)
Hydrometer
Measures density of liquid with
respect to water The electrolyte has greater specific
gravity at greater states of charge Careful opening cells,
contamination of the electrolyte solution is possible
![Page 90: Micro Hydro Power in WNC Oct 27, 2007 Andrews, NC](https://reader035.vdocuments.mx/reader035/viewer/2022062221/56649d935503460f94a79a67/html5/thumbnails/90.jpg)
Temperature Batteries get sluggish
at cold temperatures Usable capacity drops
radically below 40° F Self Discharge
happens rapidly above 120° F
Keep them between 55° F 100° F
![Page 91: Micro Hydro Power in WNC Oct 27, 2007 Andrews, NC](https://reader035.vdocuments.mx/reader035/viewer/2022062221/56649d935503460f94a79a67/html5/thumbnails/91.jpg)
Rates of Charge and Discharge
Recommended rates are C/10 – C/20 Using a C/5 rate will cause much more
electrical energy to be loss as heat This heat can damage battery plates Example –
440 Ampere-hour batteryHow many amps added for a C/10How many amps added for a C/20
![Page 92: Micro Hydro Power in WNC Oct 27, 2007 Andrews, NC](https://reader035.vdocuments.mx/reader035/viewer/2022062221/56649d935503460f94a79a67/html5/thumbnails/92.jpg)
Equalizing Charge
After time individual cells vary in their state of charge
If difference is greater than .05 volts – equalize
Controlled overcharge at C/20 rate for 7 hours
![Page 93: Micro Hydro Power in WNC Oct 27, 2007 Andrews, NC](https://reader035.vdocuments.mx/reader035/viewer/2022062221/56649d935503460f94a79a67/html5/thumbnails/93.jpg)
Battery Care
Don’t discharge beyond 80% C/10 – C/20 rate Keep batteries at room temperature Use distilled water Size batteries properly Equalize every few months Keep batteries and connections clean
![Page 94: Micro Hydro Power in WNC Oct 27, 2007 Andrews, NC](https://reader035.vdocuments.mx/reader035/viewer/2022062221/56649d935503460f94a79a67/html5/thumbnails/94.jpg)
Connecting Cells
Amperage and voltage in battery can be increased by arranging the cells in two ways Series
One path for electrons to follow Connect + to –’ Increases voltage
Parallel Multiple paths for electrons to follow Connect (+ to +) and (- to -) Increases amperage
![Page 95: Micro Hydro Power in WNC Oct 27, 2007 Andrews, NC](https://reader035.vdocuments.mx/reader035/viewer/2022062221/56649d935503460f94a79a67/html5/thumbnails/95.jpg)
Wire Sizing
![Page 96: Micro Hydro Power in WNC Oct 27, 2007 Andrews, NC](https://reader035.vdocuments.mx/reader035/viewer/2022062221/56649d935503460f94a79a67/html5/thumbnails/96.jpg)
Wire Sizing for DC Applications
Voltage drop is caused by a conductors electrical resistance
This voltage drop can be used to calculate power loss
![Page 97: Micro Hydro Power in WNC Oct 27, 2007 Andrews, NC](https://reader035.vdocuments.mx/reader035/viewer/2022062221/56649d935503460f94a79a67/html5/thumbnails/97.jpg)
VDI Voltage drop Index
Easier method for determining wire size What you need to know
Amps (Watts/volts)Feet (one-way distance)Acceptable % volt drop Voltage
![Page 98: Micro Hydro Power in WNC Oct 27, 2007 Andrews, NC](https://reader035.vdocuments.mx/reader035/viewer/2022062221/56649d935503460f94a79a67/html5/thumbnails/98.jpg)
How to Use Formula and Chart
Example: 1 KW, 24 volt system, 50 feet, 3% drop
Amps = 1000 watts/ 24 volts = 41.67 amps
VDI = 41.67 amps * 50 feet = 28.9
3% * 24 volts
![Page 99: Micro Hydro Power in WNC Oct 27, 2007 Andrews, NC](https://reader035.vdocuments.mx/reader035/viewer/2022062221/56649d935503460f94a79a67/html5/thumbnails/99.jpg)
VDI Chart
24V VDI = 28.92 AWG wire
That’s pretty big wire
What if we make it a 48 volt system?
![Page 100: Micro Hydro Power in WNC Oct 27, 2007 Andrews, NC](https://reader035.vdocuments.mx/reader035/viewer/2022062221/56649d935503460f94a79a67/html5/thumbnails/100.jpg)
How to Use Formula and Chart
Example: 1 KW, 48 volt system, 50 feet, 3% drop
Amps = 1000 watts/ 48 volts = 20.8 amps
VDI = 20.8 amps * 50 feet = 7.23
3% * 48 volts
![Page 101: Micro Hydro Power in WNC Oct 27, 2007 Andrews, NC](https://reader035.vdocuments.mx/reader035/viewer/2022062221/56649d935503460f94a79a67/html5/thumbnails/101.jpg)
VDI Chart
48V VDI = 7.28 AWG wire
That’s better (smaller, less $,
same losses).
![Page 102: Micro Hydro Power in WNC Oct 27, 2007 Andrews, NC](https://reader035.vdocuments.mx/reader035/viewer/2022062221/56649d935503460f94a79a67/html5/thumbnails/102.jpg)
Load Assessment
![Page 103: Micro Hydro Power in WNC Oct 27, 2007 Andrews, NC](https://reader035.vdocuments.mx/reader035/viewer/2022062221/56649d935503460f94a79a67/html5/thumbnails/103.jpg)
Hydro Load Assessment How do you know how
much energy you need?Electric billAverage US household
uses 850 kWhrs/month = 28 kWhrs/day
Also need capacity: what is the largest load to run?
Do a load assessment!!
![Page 104: Micro Hydro Power in WNC Oct 27, 2007 Andrews, NC](https://reader035.vdocuments.mx/reader035/viewer/2022062221/56649d935503460f94a79a67/html5/thumbnails/104.jpg)
Load Assessment A house on RE must use less electricity
Use less energy! produce the Negawatt!Efficient appliances
CF lighting Newer models (EnergyStar)
Divert heating loads to solar, gas, etc…
![Page 105: Micro Hydro Power in WNC Oct 27, 2007 Andrews, NC](https://reader035.vdocuments.mx/reader035/viewer/2022062221/56649d935503460f94a79a67/html5/thumbnails/105.jpg)
Load Assessment You’ll need for each appliance…
Power consumption In Watts Rating will be stamped on appliance
Number of hours/day appliance is on
Simple example: a 15 W CF bulb is on for an average of 5 hrs/day
day: (15 W)(5 hrs/day) = 75 Whrs/day
month: (75 Whrs/day)(30 days) = 2,250 Whrs
= 2.25 kWhrs
![Page 106: Micro Hydro Power in WNC Oct 27, 2007 Andrews, NC](https://reader035.vdocuments.mx/reader035/viewer/2022062221/56649d935503460f94a79a67/html5/thumbnails/106.jpg)
Incentives and Regulations
![Page 107: Micro Hydro Power in WNC Oct 27, 2007 Andrews, NC](https://reader035.vdocuments.mx/reader035/viewer/2022062221/56649d935503460f94a79a67/html5/thumbnails/107.jpg)
NC Renewable Energy Tax Credits
35% for all technologies Can take tax credit over 5 years No more than half of tax liability No refund based on tax credit
Credit Limits $1,400 residential solar domestic hot water$3,500 residential active space heating, combined solar hot water and space heating, passive space heating$10,500 residential biomass, wind, hydroelectric and photovoltaic or solar thermal electric
![Page 108: Micro Hydro Power in WNC Oct 27, 2007 Andrews, NC](https://reader035.vdocuments.mx/reader035/viewer/2022062221/56649d935503460f94a79a67/html5/thumbnails/108.jpg)
NC GreenPower Program
To improve the quality of the environment by encouraging the development of renewable energy resources through consumers’ voluntary purchase of green power.
Premium paid if approved by the Low Impact Hydropower Institute (LIHI)
www.ncgreenpower.org
![Page 109: Micro Hydro Power in WNC Oct 27, 2007 Andrews, NC](https://reader035.vdocuments.mx/reader035/viewer/2022062221/56649d935503460f94a79a67/html5/thumbnails/109.jpg)
Other State Incentives
www.dsireusa.org
![Page 110: Micro Hydro Power in WNC Oct 27, 2007 Andrews, NC](https://reader035.vdocuments.mx/reader035/viewer/2022062221/56649d935503460f94a79a67/html5/thumbnails/110.jpg)
Regulations
The US Army Corps of Engineers has jurisdiction over virtually all waterways in the United States. Any discharge of dredged or fill material
into all waters of the United States, which includes rearranging rocks within a streambed, would require notification of the Corps per Section
404 of the Clean Water Act.
Contact the local Army Corps of Engineers office about your proposed project beforeyou begin construction. They will help decide whether or
not a permit is required.
![Page 111: Micro Hydro Power in WNC Oct 27, 2007 Andrews, NC](https://reader035.vdocuments.mx/reader035/viewer/2022062221/56649d935503460f94a79a67/html5/thumbnails/111.jpg)
Local Installers
![Page 112: Micro Hydro Power in WNC Oct 27, 2007 Andrews, NC](https://reader035.vdocuments.mx/reader035/viewer/2022062221/56649d935503460f94a79a67/html5/thumbnails/112.jpg)
Wrap up: Site Assessment
Head Flow Pipe Length Wire Run Goals
![Page 113: Micro Hydro Power in WNC Oct 27, 2007 Andrews, NC](https://reader035.vdocuments.mx/reader035/viewer/2022062221/56649d935503460f94a79a67/html5/thumbnails/113.jpg)
MicroMicro Hydro Power in Hydro Power in WNCWNC
QuestionsQuestions