metrologyupgrade velo - rf shield 13/08/2014cernmassimiliano ferro-luzzi 1 38 scans per data set: 6...

3
metrology Upgrade VELO - RF shield 13/08/2014 CERN Massimiliano Ferro- Luzzi 1 38 scans per data set: 6 longitudinal scans over each central bulge nr 1 to 6 6 transverse scans over each bulge nr 7 to 12 7 transverse scans over each neck nr 13 to 19 repeat for other side thickness obtained from comparison of both sides I redefine "my axes"... Thickness by precise metrology Thickness by precise metrology Thanks to Didier Glaude

Upload: rachel-shields

Post on 06-Jan-2018

215 views

Category:

Documents


1 download

DESCRIPTION

metrologyUpgrade VELO - RF shield 13/08/2014CERNMassimiliano Ferro-Luzzi 3 seen from silicon detector side longer neck shorter neck inscription (sample label) inscription (sample label) z z x x y y origin My coordinate system  x=0, top of flange  y=0, edge of flange  z=0, edge of flange plot each y-scan offset by incremental +35mm for clarity

TRANSCRIPT

Page 1: MetrologyUpgrade VELO - RF shield 13/08/2014CERNMassimiliano Ferro-Luzzi 1 38 scans per data set:  6 longitudinal scans over each central bulgenr 1 to

metrology Upgrade VELO - RF shield 13/08/2014 CERN Massimiliano Ferro-Luzzi 1

38 scans per data set:6 longitudinal scans over each central bulge nr 1 to 66 transverse scans over each bulge nr 7 to 127 transverse scans over each necknr 13 to 19repeat for other sidethickness obtained from comparison of both sides

I redefine "my axes"...

Thickness by precise metrology Thickness by precise metrology Thanks to Didier Glaude

Page 2: MetrologyUpgrade VELO - RF shield 13/08/2014CERNMassimiliano Ferro-Luzzi 1 38 scans per data set:  6 longitudinal scans over each central bulgenr 1 to

metrology Upgrade VELO - RF shield 13/08/2014 CERN Massimiliano Ferro-Luzzi 2

seen from silicon detector sideseen from silicon detector side

longer neck

shorter neck

inscription(sample label)YDidier

XDidier

ZDidier

origin

Didier Glaude's coordinate system

X=0, top of flange Y=0, edge of flange Z=0, edge of flange

Page 3: MetrologyUpgrade VELO - RF shield 13/08/2014CERNMassimiliano Ferro-Luzzi 1 38 scans per data set:  6 longitudinal scans over each central bulgenr 1 to

metrology Upgrade VELO - RF shield 13/08/2014 CERN Massimiliano Ferro-Luzzi 3

seen from silicon detector sideseen from silicon detector side

longer neck

shorter neck

inscription(sample label)z

x

y

origin

My coordinate system

x=0, top of flange y=0, edge of flange z=0, edge of flange

plot each y-scan offset by incremental +35mm for clarity