Meter Mounting Equipment
DTE Energy Area
MIL
BA
NK
OV
ERV
IEW
MILBANK OVERVIEW2
2
ilbank ManufacturingCompany was estab-lished in 1927 byCharles A. Milbank.
Originally, the company manu-factured high voltage switches;however, by 1941 Milbank devot-ed itself primarily to the manufac-ture of sheet metal enclosuresand related equipment for theelectrical generation and distribu-tion industry. Today we are anindustry leader in the manufac-ture of electrical meter sockets.Through a national network ofmanufacturer’s representatives weprovide wholesale electrical dis-tributors with quality electricalproducts for the utility, contractor,industrial and OEM markets.
As the meter standards havechanged, Milbank has been suc-cessful in adapting its productline to these changes. Our fullscale engineering departmentdesigns products to meet cus-tomer specifications and satisfyall utility requirements.
Milbank’s employee base of over1,000 with our five manufactur-ing facilities comprising almost550,000 square feet gives us theflexibility to schedule, produce,and ship orders quickly.Currently, Milbank manufacturesover 10,000 different catalogitems, and this list continues togrow. Our unique product offer-ing includes: Residential &Commercial Meter Sockets;Residential & Commercial MeterPedestals; RV/MH Power Outlets,Pedestals, and Transformers;Commercial & IndustrialElectrical Enclosures; CircuitBreakers; Disconnects & SafetySwitches; Safety Sockets; Utility &Residential Secondary Pedestals;Hubs and related accessories. Ifyou don’t find a unit in this cata-log to service your needs, send usyour specifications and we willbe happy to work with you.
Our success has come from aloyal customer base that can relyon us to build quality products at
a fair price in a timely manner.Our willingness and ability todesign and produce new productsto meet our customer demands isan important factor to remaincompetitive in today’s electricalmarket.
Milbank has been serving theelectric utility & wholesale distri-bution industries for over 75years with innovative, qualityengineered products. So remem-ber us for all of your metermounting and related require-ments, and we will be happy toserve you as we have in thepast—with dependable serviceand quality products!
We take great pride in beingone of the few family-ownedbusinesses left in our industry.We are a third generation runbusiness and truly believe that...
FAMILY MAKES ADIFFERENCE!
Charles A. Milbank1879-1966
Bill Martin Robert F. Waldrop,1922-2002
Robert F. Waldrop, IIChairman
Katrina Waldrop HenkeVice Chairman
MMilbank–Quality Metering Products for over 75 Years
3TA
BLE O
F CO
NTEN
TSTABLE OF CONTENTS
Catalog Number Logic . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4
DISCONNECTSU3800 . . . . . . . . . . . . . . . . . . . .60 Amp Non-Fusible AC Disconnect . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .5U3803 . . . . . . . . . . . . . . . . . . . .30 Amp Fusible AC Disconnect . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .5U3806 . . . . . . . . . . . . . . . . . . . .60 Amp Fusible AC Disconnect . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .5U3822-20GR . . . . . . . . . . . . . .60 Amp Non-Fused AC Disconnect / 20 Amp GFCI Receptacle . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .6U4881-O-50GB . . . . . . . . . . . .50 Amp Spa Box with GFCI Protection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .6U4881-O-60GB . . . . . . . . . . . .60 Amp Spa Box with GFCI Protection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .6U4881-O . . . . . . . . . . . . . . . . . .Spa Box with Breaker Provision & GFCI Protection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .6
SINGLE POSITION DTE NO.U7487-O-TG . . . . . . . . . . . . . . .125 Amp, 4 Terminal, OH/UG . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .ZSW-100 . . . . . . . . . . . . .7U7040-RL-TG . . . . . . . . . . . . . .200 Amp, 4 Terminal, OH/UG . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .ZSU-200 . . . . . . . . . . . . . .7U7021-RL-TG . . . . . . . . . . . . . .200 Amp, 4 Terminal, OH . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .ZS-200 . . . . . . . . . . . . . .7
SINGLE POSITION HEAVY DUTY LEVER BYPASSU9801-RXL . . . . . . . . . . . . . . .200 Amp, 4 Terminal, 1∅3W, OH/UG . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .N/A . . . . . . . . . . . . . . . .8U9701-RXL . . . . . . . . . . . . . . .200 Amp, 7 Terminal, UG, 3∅4W . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .ZS3-200H, ZS3-200P . . . . . . . .8U1129-O . . . . . . . . . . . . . . . . . .320 Amp, 4 Terminal, UG, 1∅3W . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .ZSU-320 . . . . . . . . . . . . . .9
MULTIPLE POSITION (HORIZONTAL GANGS) U1252-X . . . . . . . . . . . . . . . . . .2 Position, 200 Amp / Pos., 4 Terminal, 1∅3W, OH/UG . . . . . . . . . . . . . . . . . . . . . . . .ZS2-200 . . . . . . . . . . . . .10
CT ENCLOSURES AND SOCKETSUC7444-O-201 . . . . . . . . . . . . .20 Amp, 8 Terminal, Transformer Rated, Prewired with Test Switch . . . . . . . . . . . . . .ZS3-20-5S . . . . . . . . . . . .11UC7445-O-521 . . . . . . . . . . . . .20 Amp, 13 Terminal, Transformer Rated, Prewired with Test Switch . . . . . . . . . . . . .ZS3-20-9S . . . . . . . . . . . .11
CONDOMINIUM METER BANKS U2351-RXL . . . . . . . . . . . . . . .1 Position, 125 Amp / Pos., 4 Terminal, Not Bussed . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .12U2852-X . . . . . . . . . . . . . . . . . .2 Position, 125 Amp / Pos., 4 Terminal, 200 Amp Main Bus Rating . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .12U2853-X . . . . . . . . . . . . . . . . . .3 Position, 125 Amp / Pos., 4 Terminal, 200 Amp Main Bus Rating . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .12U2854-X . . . . . . . . . . . . . . . . . .4 Position, 125 Amp / Pos., 4 Terminal, 400 Amp Main Bus Rating . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .12U2855-X . . . . . . . . . . . . . . . . . .5 Position, 125 Amp / Pos., 4 Terminal, 400 Amp Main Bus Rating . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .12U2856-X . . . . . . . . . . . . . . . . . .6 Position, 125 Amp / Pos., 4 Terminal, 400 Amp Main Bus Rating . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .12U2288-RXL . . . . . . . . . . . . . . .1 Position, 200 Amp / Pos., 4 Terminal, Not Bussed . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .12U2862-X . . . . . . . . . . . . . . . . . .2 Position, 200 Amp / Pos., 4 Terminal, 250 Amp Main Bus Rating . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .12U2863-X . . . . . . . . . . . . . . . . . .3 Position, 200 Amp / Pos., 4 Terminal, 300 Amp Main Bus Rating . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .12U2864-X . . . . . . . . . . . . . . . . . .4 Position, 200 Amp / Pos., 4 Terminal, 400 Amp Main Bus Rating . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .12U2865-X . . . . . . . . . . . . . . . . . .5 Position, 200 Amp / Pos., 4 Terminal, 600 Amp Main Bus Rating . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .12U2866-X . . . . . . . . . . . . . . . . . .6 Position, 200 Amp / Pos., 4 Terminal, 600 Amp Main Bus Rating . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .12
MOBILE HOMEU5136-O-100S . . . . . . . . . . . . .1 Position Pedestal, 100 Amp / Pos., 4 Terminal, Circuit Breaker Provisions . . . . . . . . . . . . . . . . . . . . . . . . . . . .14U5136-O-200S . . . . . . . . . . . . .1 Position Pedestal, 200 Amp / Pos., 4 Terminal, Circuit Breaker Provisions . . . . . . . . . . . . . . . . . . . . . . . . . . . .14U5136-O-200S/22 . . . . . . . . . .1 Position Pedestal, 200 Amp / Pos., 4 Terminal, Circuit Breaker Provisions, 22K AIC Rated . . . . . . . . . . . . . . .14U5137-O-100S . . . . . . . . . . . . .2 Position Pedestal, 100 Amp / Pos., 4 Terminal, Circuit Breaker Provisions . . . . . . . . . . . . . . . . . . . . . . . . . . . .14U5137-O-200S . . . . . . . . . . . . .2 Position Pedestal, 200 Amp / Pos., 4 Terminal, Circuit Breaker Provisions . . . . . . . . . . . . . . . . . . . . . . . . . . . .14U5137-O-200S/22 . . . . . . . . . .2 Position Pedestal, 200 Amp / Pos., 4 Terminal, Circuit Breaker Provisions, 22K AIC Rated . . . . . . . . . . . . . . .14
ACCESSORIES . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .15-16
MISCELLANEOUSConduit & Ampacity Information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .17Energization of Electrical Equipment . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .18Additional Milbank Products . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .19
3
CATALOG NUMBER LOGIC4C
ATA
LOG
NU
MB
ER L
OG
IC
4
530 &
60 AM
P–FUSIB
LE / NO
N-FU
SIBLE–A
IR C
ON
DITIO
NER
DISC
ON
NEC
TS30 & 60 AMP–FUSIBLE / NON-FUSIBLE–AIR CONDITIONER DISCONNECTS
5
U3800(No deadfront required)
Milbank’s air conditioner disconnect has a removable hinged cover which makes wiring a breeze. Ourcompact design meets all wire bending space requirements in the NEC and also complies with article440-14 in the NEC. To insure the safest conditions, we designed our disconnect pullers to be remov-able or they may be reinstalled in the “off” position. Another safety feature is the padlock provision onthe front cover. As with all Milbank products, our enclosure is constructed of G90U galvanized steeland finished with an attractive, light gray, baked powder coating. Our state of the art finish combinesepoxy and polyester hybrid resins into a hybrid powder coating which is then electrostatically applied.This offers a durable, non-fading finish.
TECHNICAL INFORMATION
AMP TYPE CATALOGNUMBER
MAXH.P.
WT.#
30 FUSIBLE U3803 3 3.7
60 FUSIBLE U3806 10 3.7
60 NONFUSIBLE U3800 10 3.25
LINE & LOADWIRE RANGE
GROUNDWIRE RANGE DIMENSIONS WIRE RATING
CU AL CU/AL
#14-#2AWG
#12-#2AWG #12-2 AWG
#14-#2AWG
#12-#2AWG #12-2 AWG
#14-#2AWG
#12-#2AWG #14-4 AWG
D″″ W″″ H″″ CU °°C AL °°C
3 5 91⁄4 60°/75° 60°
3 5 91⁄4 60°/75° 60°
3 5 8 60°/75° 60°/75°
PROFILE
U3800 is UL Listed without deadfront. Line andload terminations are fully insulated.
U3800 std. quantity is 20 per carton.
U3803 & U3806 std. quantity is 6 percarton.
�
�
�
U3803
U3806
AC DISCONNECT / SPA BOX6A
C D
ISC
ON
NEC
T /
SPA
BO
X
6
• Meets NEC # 210.63 Requirements *• UL Listed as Power Outlet• Type 3R Enclosure• In-Use Cover**• Duplex Ground Connector• 1” Concentric Knockouts
AC DISCONNECT• 1∅∅, 240 Volt• 60 amp, Non-Fused
GFCI RECEPTACLE• 20 amp• Reset/Test Button• Padlock provision
Combination AC Disconnect / 20 Amp GFCI Receptacle–Together in 1 Box
To ensure the safest conditions, Milbank disconnect pullers are designed to be reversible so they may be reinstalled in the OFF position.All units are designed with a padlock provision on the cover for security.
**Note: U3822-20GR cover rated as IN-USE COVER (Cover may be closed with cords plugged into receptacle).*Reprinted with permission from NFPA 70-2002, National Electrical Code®, Copyright 2001, National Fire Protection Association, Quincy, MA 02269. This reprinted material is not the completeand official position of the NFPA on the referenced subject, which is represented only by the standard in its entirety. National Electrical Code® and NEC® are registered trademarks of theNational Fire Protection Association, Quincy, MA.
* NEC® #210.63 Heating, Air-Conditioning and RefrigerationEquipment Outlet. ...The receptacle shall be locat-ed on the same level and within7.5 m (25 ft.) of the heating, air-conditioning and refrigerationequipment.
* NEC® #210.08 Ground-FaultCircuit– Interruptor protectionfor personnel.
U4881-O-50GB
AMP TYPE CATALOGNUMBER
WT.#
–BREAKER
PROVISION U4881-O 7
LINE & LOAD CONNECTORWIRE RANGE
GROUND CONNECTORWIRE RANGE DIMENSIONS
CU AL CU/AL
#14-1/0 #14-1/0 #14-1/0
D″″ W″″ H″″
3 3⁄4 71⁄2 81⁄2
50
60
BREAKER
BREAKER
U4881-O-50GB
U4881-O-60GB
8
8
#14-1/0
#14-1/0
#14-1/0
#14-1/0
#14-1/0
#14-1/0
3 3⁄4
3 3⁄4
71⁄2
71⁄2
81⁄2
81⁄2
•• 240 volt ground fault protection•• UL listed, Type 3R rainproof•• Milbank reliability•• Easy installation•• 2 pole, 50 amp GFCI breaker protection•• Compact size:
8-1/2” H x 7-1/2” W x 3-3/4” D•• 3 or 4 wire installation•• 1∅∅, 120 / 240 VAC•• Standard package of 12•• 2 extra one-pole breaker spaces•• 100 amp overall rating
Sub Panel Breaker Enclosure•• Use as a 100 amp, 4 circuit sub panel
enclosure• U4881-O has provision for (2) 2-pole or
(4) 1-pole small frame breakers
Hot Tub Disconnect or Sub Panel Breaker Enclosure–Type 3RSpa Box with GFCI Protection
U3822-20GR
60 amp, Non-Fused AC Disconnect
Duplex 20 ampGFCI Receptacle
Type 3REnclosure withIn-Use Cover
AMP TYPE CATALOGNUMBER
MAXH.P.
WT.#
60 NONFUSIBLE U3822-20GR 10 6
LINE & LOAD CONNECTORWIRE RANGE
GROUND CONNECTORWIRE RANGE DIMENSIONS WIRE RATING
CU AL CU/AL
#14-#2AWG
#12-#2AWG #14-4 AWG
D″″ W″″ H″″ CU °°C AL °°C
4.8 5.25 7.4 60°/75° 60°/75°
OHZS-200
ZSU-200 UGU7040-RL-TG* H.O. 21⁄2 21⁄2 21⁄2 21⁄2 1⁄4,
1⁄2 1⁄441⁄8 11 151⁄2#6-350 kcmil #6-350 kcmil
7
Utility requirements for this equipment may vary. Always consult the serving utility for their requirements before ordering orinstalling equipment in this catalog.
7
125 / 200 AMP–4 & 5 TERMINAL-RINGLESS–600 VAC125 / 200 A
MP–4 &
5 TERM
INA
L-RIN
GLESS–600 V
AC
SERVICEDTE NO. CATALOGNUMBER
HUB
UGZSW-100 U7487-O-TG BLANK
CONNECTORSCU/AL
LINE LOAD
DIMENSIONS CONCENTRIC K.O.’S
1 2 3 4 5 6
11⁄2 11⁄2 2 11⁄4 — 1⁄4
D″″ W″″ H″″
35⁄16 8 111⁄2#6-2/0 #6-2/0
OHZS-200 U7021-RL-TG H.O. 21⁄2 21⁄2 21⁄2 — 1⁄4 1⁄4 ,1⁄241⁄8 8 151⁄2#6-350 kcmil #6-350 kcmil
125 AMP–4 TERMINAL–RINGLESS
FIFTH TERMINAL: For field mounted fifth terminal order catalog number 5T8K2 for 125 amp unit. For 200 amp units, order K5T.CONNECTORS: Extruded aluminum connectors are tin plated. Units are supplied with duplex neutral.*UNDERGROUND SERVICE: A closing plate must be used when the U7040-RL is used for underground service. Order closing
plate catalog number A7551 as extra. For overhead service, order hub separately. See page 15.
SERVICEDTE NO. CATALOGNUMBER
HUBCONNECTORS
CU/AL
LINE LOAD
DIMENSIONS CONCENTRIC K.O.’S
1 2 3 4 5 6D″″ W″″ H″″
200 AMP–4 TERMINAL–RINGLESS
1 2
35
6
6
1 2
34 45 6
702170407487
U7487-O-TGU7040-RL-TG
U7021-RL-TG
200 AMP–4 & 7 TERMINAL–RINGLESS–JAW CLAMPING LEVER–600 VAC820
0 A
MP–
4 &
7 T
ERM
INA
L–R
ING
LESS
–JA
W C
LAM
PIN
G L
EVER
–600
VA
C
Utility requirements for this equipment may vary. Always consult the serving utility for their requirements before ordering orinstalling equipment in this catalog.
8
3 21⁄2 3 3 1⁄4 1⁄4,1⁄247⁄8 13 19
DIMENSIONS CONCENTRIC K.O.’S
1 2 3 4 5 6D″″ W″″ H″″
HUBS: For proper hub selection see the hub suffix chart on the accessory page.BYPASS: Lever supplies clamping action on meter spades and also operates bypass device.CONNECTORS: Units are supplied with extruded aluminum connectors and bonded, triplex neutral. FIFTH TERMINAL: For field mounted fifth terminal, order as extra K3866.
U9801-RXL
1 2
34 465
98019701
200 AMP—4 TERMINAL—RINGLESS—1∅∅3W
DIMENSIONS CONCENTRIC K.O.’S
1 2 3 4 5 6D″″ W″″ H″″
3 21⁄2 3 31⁄4 1⁄4,
1⁄247⁄8 13 19
200 AMP–7 TERMINAL–RINGLESS–3∅∅4W
HUBS: For proper hub selection see the hub suffix chart on the accessory page.
BYPASS: Lever supplies clamping action on meter spades and also operates bypass device.
CONNECTORS: Units are supplied with extruded aluminum connectors and bonded, triplex neutral. INSULATED NEUTRAL: For field installed insulated neutral for the U9701 order kit number K1047.
U9701-RXL
DTE NO.
N/A 200 OH/UG U9801-RXL C.P. #6-350 kcmil #6-350 kcmil
AMP SERVICE CATALOGNUMBER
HUBCONNECTORS
CU/AL
LINE LOAD
AMP SERVICE CATALOGNUMBER
HUBCONNECTORS
CU/AL
LINE LOAD
200OH
UGU9701-RXL C.P. #6-350 kcmil #6-350 kcmil
ZS3-200H
ZS3-200P
DTE NO.
DTE NO.
ZSU-320
9320 A
MP–4 TER
MIN
AL–R
ING
LESS–JAW
CLA
MPIN
G LEV
ER–600 V
AC
320 AMP–4 TERMINAL–RINGLESS–JAW CLAMPING LEVER–600 VAC
Utility requirements for this equipment may vary. Always consult the serving utility for their requirements before ordering orinstalling equipment in this catalog.
9
U1129-O
1
65
4 3 4
2
320 UG U1129-O BLANK 3 21⁄2 3 3 1⁄4 1⁄4,1⁄247⁄8 15 303/8”-16 STUDS 3/8”-16 STUDS
AMP SERVICE CATALOGNUMBER
HUBCONNECTORS
CU/AL
LINE LOAD
DIMENSIONS CONCENTRIC K.O.’S
1 2 3 4 5 6D″″ W″″ H″″
HUBS: For proper hub selection see the hub suffix chart on the accessory page.BYPASS: Lever supplies clamping action on meter spades and also operates bypass device.CONNECTORS: For connector kits, order as extra K1350 (twin 350) or K1540 (single 600). Separate kits are required for line
and load. FIFTH TERMINAL: For field mounted fifth terminal order catalog number K3865.
320 AMP—4 TERMINAL—RINGLESS—1∅∅3W
DTE NO.
ZS2-200
200 AMP/POSITION—4 TERMINAL—HORIZONTAL GANG—300 VAC1020
0 A
MP/
POSI
TIO
N—
4 TE
RM
INA
L—H
OR
IZO
NTA
L G
AN
G—
300
VA
C
Utility requirements for this equipment may vary. Always consult the serving utility for their requirements before ordering orinstalling equipment in this catalog.
10
2 OH/UG U1252-X C.P. 21⁄2 3 21⁄21⁄2 1⁄4,
1⁄2 1⁄4,1⁄2,151⁄8 261⁄2 143/8”-16 STUDS #6-350 kcmil
NO.OF
POSSERVICE CATALOG
NUMBERHUB
CONNECTORSCU/AL
LINE LOAD
DIMENSIONS CONCENTRIC K.O.’S
1 2 3 4 5 6D″″ W″″ H″″
HUBS: For proper hub selection see the hub suffix chart on the accessory page.FIFTH TERMINAL: For field mounted fifth terminal in the 9 o’clock position, order catalog number K5T.CONNECTORS: Extruded aluminum connectors are tin plated.BUSSING: Bussing is 5/16” x 1” aluminum. AMPS: Rated 200 amp per position / 400 amp overall.
200 AMP/POSITION—4 TERMINAL—RINGLESS—1∅∅3W
1 1 1
23 35 64 4
U1252-X
1120 A
MP–8 &
13 TERM
INA
L–TRA
NSFO
RM
ER R
ATED
–TEST SWITC
H PR
OV
ISION
–600 VA
C20 AMP–8 & 13 TERMINAL–TRANSFORMER RATED–TEST SWITCH PROVISION–600 VAC
Utility requirements for this equipment may vary. Always consult the serving utility for their requirements before ordering orinstalling equipment in this catalog.
11
1 PIECE COVER—RINGLESS—WITH PREWIRED TEST SWITCH
NO.OF
TERMS
CATALOGNUMBER
HUB CONNECTORSCU
DIMENSIONS CONCENTRIC K.O.’S
1 2 3 4 5 6D″″ W″″ H″″
8 UC7444-O-201 BLANK #14 - #4 MAX 11⁄4 11⁄4 11⁄4 11⁄4 11⁄4 1⁄4,1⁄241⁄8 12 20
13 UC7445-O-521 BLANK #14 - #4 MAX 11⁄4 11⁄4 11⁄4 11⁄4 11⁄4 1⁄4,1⁄241⁄8 12 20
1
3 4 56
2
CONNECTORS: Units are supplied with sleeve type connectors (#4 max).
UC7445-O-521NOTE: Picture is NOT shown with
DTE-specified wiring configuration.
DTE NO.
ZS3-20-5S
ZS3-20-9S
CONDOMINIUM METER BANKS12C
ON
DO
MIN
IUM
MET
ER B
AN
KS
Utility requirements for this equipment may vary. Always consult the serving utility for their requirements before ordering orinstalling equipment in this catalog.
12
U2854-X-4/125(Order circuit breakers as extra)
U2866-X
CATALOGNUMBER
NO.OF
POS.
1
2
3
MAIN BUSRATING
LINECONNECTOR
SIZE
U2351-RXL NOT BUSSED
U2852-X 200 AMP
U2853-X 200 AMP
#6-2/0 AWG
*3/8″-16 STUD
*3/8″-16 STUD
CATALOGNUMBER
NO.OF
POS.
1
2
3
MAIN BUSRATING
LINECONNECTOR
SIZE
U2288-RXL NOT BUSSED
U2862-X 250 AMP
U2863-X 300 AMP
#6-250 AWG
*3/8″-16 STUD
*3/8″-16 STUD
CATALOGNUMBER
NO.OF
POS.
4
5
6
MAIN BUSRATING
LINECONNECTOR
SIZE
U2854-X 400 AMP
U2855-X 400 AMP
U2856-X 400 AMP
*3/8″-16 STUD
*3/8″-16 STUD
*3/8″-16 STUD
CATALOGNUMBER
NO.OF
POS.
4
5
6
MAIN BUSRATING
LINECONNECTOR
SIZE
U2864-X 400 AMP
U2865-X 600 AMP
U2866-X 600 AMP
*3/8″-16 STUD
*3/8″-16 STUD
*3/8″-16 STUD
SIZE SUFFIX
SINGLE
TWIN
K1539-K1
-K3
-K2
-K4
K1540
K1350
K1541
U2852-56U2862-66
U2854-56U2864-66
U2854-56U2863-66
U2864-66
#6-350kcmil
#4-600kcmil
#6-350kcmil
#2-600kcmil
KITNUMBER
COMPATIBLEWITH
WIRERANGE
*CONNECTORS: For line wire connector kits, orderseparately.
FIFTH TERMINALS: For field mounted fifth terminalorder catalog number K2381. Order one per meterposition (9 o’clock position only).
BREAKERS: Units have provision for one doublepole main per meter position. Breakers not includ-ed. Order as extra Milbank type Q or QNR or com-parable. Refer to accessories section in back ofcatalog.
125 AMP/POSITION 200 AMP/POSITION
125 AMP/POSITION 200 AMP/POSITION
CONNECTOR KITS *
VERTICAL
RECTANGULAR
13C
ON
DO
MIN
IUM
METER
BA
NK
SCONDOMINIUM METER BANKS
Utility requirements for this equipment may vary. Always consult the serving utility for their requirements before ordering orinstalling equipment in this catalog.
13
A A
CBEEE
BC C
D D D
BE E E C
29" or 41"
5 13/16"
13" or 18"
21"
25" or 37"
5 13/16"
18"
21"
5 13/16"
CB
D
A
CB
D
E E E E E E
A A A AA
29" or 41"
4 7/8"
36"
37" or 25"
4 7/8"
31"
VERTICAL
RECTANGULAR
125 & 200 amp/pos.(single position)
125 amp/pos.(2-3 position)
200 amp/pos.(2-3 position)
125 amp/pos.(4,5 & 6 position)
200 amp/pos.(4,5 & 6 position)
CONDOMINIUMMETERING BANKS
U2852-X
FIG.
A
B
C
D
E
DIMENSIONS
11⁄4 ″ CONCENTRIC K.O.
1⁄4,1⁄2″ CONCENTRIC K.O.
3″ CONCENTRIC K.O.
4″ HUB OPENING
2″ CONCENTRIC K.O.
200 AMP–MOBILE HOME METER PEDESTALS–4 TERMINAL–RINGLESS–120 / 240 VAC1420
0 A
MP–
MO
BIL
E H
OM
E M
ETER
PED
ESTA
LS–4
TER
MIN
AL–
RIN
GLE
SS–1
20 /
240
VA
C
14
�
• UL Listed File E90945.
• 200 amp maximum, 120/240 V, 1∅3W.
• Ringless type meter socket with horn bypass and stainlesssteel latch.
• Short circuit withstand rating 10K AIC, for 22K AIC, order with“22” suffix.
• Type 3R construction for durable outdoor use.
• Milbank grey polyester powder coat finish.
• Wire terminations accept copper or aluminum conductors.
• Line & Neutral: (2) #6-350 kcmil per phase.
• Line Ground: (4) #14-1/0.
• Load (CB): 1/0 to 300 kcmil per pole.
• Load Neutral: (1) #6-350 kcmil.
• Load Ground: (2) #14-1/0, (4) #14/6.
• Commercial grade, plug-in main circuit breaker. Available in100, 125, 150 & 200 amp. Type UQFP-M.
• 4 circuit plated copper interior accepts (2) 2-pole or (4) 1-polestandard plug-in type circuit breakers. Branch circuit ratedto 125 amps max. Acceptable manufacturers: Milbank, Cutler-Hammer, GE or Siemens.
• Factory or field installable receptacle bridge and receptacle /circuit breaker kits available. See accessories below.
U5136-O-200S
SINGLE PEDESTALCATALOG # MAIN BREAKER AMPS INTERIOR WEIGHT (lbs)U5136-O-100S UQFP-M-100 100 4 Circuit 82U5136-O-200S UQFP-M-200 200 4 Circuit 82U5136-O-200S/22* UQFPH-M-200 200 4 Circuit 82
DOUBLE PEDESTALCATALOG # MAIN BREAKER AMPS INTERIOR WEIGHT (lbs)U5137-O-100S (2) UQFP-M-100 Series 100 4 Circuit 115U5137-O-200S (2) UQFP-M-200 Series 200 4 Circuit 115U5137-O-200S/22* (2) UQFPH-M-200 Series 200 4 Circuit 115
RECEPTACLE / CIRCUIT BREAKER KITS AND ACCESSORIES (Sold separately)CATALOG # RECEPTACLE CIRCUIT BREAKER CONDUCTOR CONFIGURATIONK5400-520 5-20R Duplex 20 amp, 1 Pole 12 Awg
K5400-520GR 5-20R Duplex GFI 20 amp, 1 Pole 12 Awg GFI Rec.
K5400-TT30 TT30R 30 amp, 1 Pole 10 Awg
K5400-1450 14-50R 50 amp, 2 Pole 8 Awg
K5400-BRIDGE-1POS Self-grounded one position receptacle bridge with hardwareK5400-BRIDGE-2POS Self-grounded two position receptacle bridge with hardwareK5415 Stabilizer foot with hardwareK5035 Pad mount kit with hardware (see note below)K5T 5th terminal for 3 or 9 o’clock positionK5193 Wire kit to convert series wired main breaker to parallel
• A maximum of two receptacle / circuit breaker kits can be installed in each power head. Order from above. Other kits available.Consult factory for factory-installed receptacle kits.
• Receptacle / circuit breaker kits include receptacle, circuit breaker, wire, cover plate and mounting screws. • Receptacle bridge K5400-BRIDGE-1POS or K5400-BRIDGE-2POS not included with pedestal. Order separately.• Pedestals are stocked with series wired main circuit breakers. Order K5193 kit to field convert to parallel main lug circuit
breaker. For parallel wired main circuit breakers, change “S” suffix to “P” (Ex.: U5136-O-100P).• K5415 Stabilizer Foot sold separately. Recommended for double pedestals.• Pad mount pedestals available. Order U5138 (single meter) or U5139 (double meter) prefix. K5035 pad mount kit required.
Order separately.
24”
*
15A
CC
ESSOR
IESACCESSORIES
Utility requirements for this equipment may vary. Always consult the serving utility for their requirements before ordering orinstalling equipment in this catalog.
15
INTERCHANGEABLE UNIT HUBS
CLOSING COVERS
METAL CLOSING PLATE(for ringless sockets)
CP-21
METER CLOSING PLATE(Grey Plastic)
6003
HUBADAPTER PLATE
(Converts 4″ opening to21⁄2″ opening)
S8324
FIFTH TERMINALS
PLUG-IN FIFTH TERMINAL5T8K2
(Fits in round hole of oldstyle block)
FIFTH TERMINALK5T
(Fits in square holeof new style 200 amp block)
HEAVY DUTY JAWCLAMPING
K3865
FOR CONDO METERING BANKS(125-200 AMP) K2381
HUB SUFFIX CHART
O Plain Top WL 1″ For -RL OpeningYL 11⁄4″ For -RL OpeningZL 11⁄2″ For -RL OpeningDL 2″ For -RL OpeningELF
G
H
21⁄2″ For -RL Opening
3″ For -R Opening
31⁄2″ For -R Opening
4″ For -R Opening
RL Small Hub OpeningR Large Hub OpeningXL Small Closing PlateX
RXL Large Hub Openingadapted to small Closing Plate
RRL Large Hub Openingadapted to small Hub Opening
Large Closing Plate
REMOVABLE HUBCLOSING PLATE
DESCRIPTION SUFFIX CAT. #
STANDARD(for -RL opening)
-XL A7551
LARGE(for -R opening)
-X A9064
1″WL
SIZESUFFIX MILBANKNO.
YLZLDLEL
A751411⁄4″ A751511⁄2″ A75162″ A7517
21⁄2″ A7518
3″F
SIZESUFFIX MILBANKNO.
GH
A811031⁄2″ A81114″ A8112
SMALL “RL"OPENING(STANDARD)
LARGE “R” OPENING(HEAVY DUTY)
HEAVY DUTY JAWCLAMPING
K3866
ACCESSORIES16A
CC
ESSO
RIE
S
Utility requirements for this equipment may vary. Always consult the serving utility for their requirements before ordering orinstalling equipment in this catalog.
16
MILBANK2-POLE—200 AMP LARGE FRAME—10K AIC & 22K AIC
AMPS
100 UQFP-100
125 UQFP-125
150 UQFP-150
175 UQFP-175
200 UQFP-200
10K AICPLUG-IN
UQFPH-100
UQFPH-125
UQFPH-150
UQFPH-175
UQFPH-200
UQFB-100
UQFB-125
UQFP-150
UQFB-175
UQFB-200
10K AICBOLT-ON
22K AICPLUG-IN
UQFP-M-100
UQFP-M-125
UQFP-M-150
UQFP-M-175
UQFP-M-200
10K AICPLUG-IN
UQFPH-M-100
UQFPH-M-125
UQFPH-M-150
UQFPH-M-175
UQFPH-M-200
22K AICPLUG-IN
UQFB-100-X1
UQFB-125-X1
UQFP-150-X1
UQFB-175-X1
UQFB-200-X1
10K AICBOLT-ON
UQFBH-100
UQFBH-125
UQFBH-150
UQFBH-175
UQFBH-200
22K AICBOLT-ON
ISOLATEDNEUTRAL
KITK1047
PLUG-IN BREAKER COMPATIBILITY CHART
AMPS CUTLER-HAMMER(WESTINGHOUSE)
SIEMENS(ITE)
SIEMENSMURRAY /
CROUSE-HINDSG.E. SQ-D
125-200 HQP / BR / WBJ Q / QN MD Q LINE —
≤≤ 100 QUICKLAG P /BR / HQP QP MP Q LINE HOMELINE
DISCONNECT SLEEVE
M5-144
CONNECTOR KITS
For use with 3/8”-16stud type units only
SINGLETWIN
K1350K2 6-350 kcmil
K1350L
K1541
K2L
K4
6-350 kcmil Non-rotating
4-600 kcmil
CATALOG #SUFFIX (3 per set) – 1 ∅∅
K3442K6 6-350 kcmil K3083K8 4-600 kcmil
CATALOG #SUFFIX (4 per set) – 3 ∅∅
K3082K5 6-350 kcmil
K3441K74-600 kcmil or
(2) 1/0-250 kcmil
CATALOG #SUFFIX (4 per set) – 3 ∅∅
K1539K1 6-350 kcmil
K1540
K1540L
K3
K3L
4-600 kcmil or(2) 1/0-250 kcmil
4-600 kcmil or(2) 1/0-250 kcmil
Non-rotating
CATALOG #SUFFIX (3 per set) – 1 ∅∅
Replaces the load side slide-in nut assembly onMilbank 200 amp sockets. Allows for a 100 amp taplocation in addition to the #6-350 kcmil load-sideconnector. K5022 Includes Safety BarrierExtensions–for applications over 300 VAC.
K4977-INT INTERNAL HEX
K5022-INT INTERNAL HEX
LOAD TAP CONNECTORS (3 per set)
17C
ON
DU
IT AN
D A
MPA
CITY
INFO
RM
ATIO
NCONDUIT AND AMPACITY INFORMATION
17
TYPE
RHW & RHH(without outer covering)
THW
CONDUCTORSIZE
AWG,MCM1412108
CONDUIT TRADE SIZES (INCHES)1⁄2 3⁄4 1 11⁄4 11⁄2 2 21⁄2 3 31⁄2 46441
10863
1613115
29241910
40322613
65534322
93766132
1431179549
19215712766
16385
6 1 2 3 7 10 16 23 36 48 62
3 1 1 2 4 6 10 15 23 31 40
1/02/03/04/0
250300350400500
600700750
111
1111
2111
3321
5543
8765
121097
16141210
21181513
11
11111
11111
22111
43321
65443
87654
109876
111
111
111
322
433
544
TWTHW
FEPB (6 thru 2),RHW and
RHH(without outer covering)
RH, THHW
*This table is for concentric stranded conductors only. For cables with compact conductors refer to N.E.C.
*CU
A
18161412108
64321
1/02/03/04/0
250300350400500
600700750
255285310335380
420460475
——
20�
25�
35�50
6585100115130
150175200230
B
250300350400500
600700750
———12108
64321
1/02/03/04/0
A
AL or CU-Clad AL
205230250270310
340375385
———
20�
30�40
50657590100
120135155180
C
AMBIENTTEMP.C°°
CORRECTIONFACTOR
AMBIENTTEMP.F°°
21 - 25 1.05 70 - 7726 - 30 1.00 79 - 8631 - 35 .94 88 - 9536 - 40 .88 97 - 10441 - 45 .82 106 - 11346 - 50 .75 115 - 12251 - 55 .67 124 - 13156 - 60 .58 133 - 14061 - 65 .33 142 - 15866 - 70 — 160 - 176
* ALLOWABLE AMPACITIES OF INSULATED COPPER &ALUMINUM CONDUCTORS (3W IN CONDUIT) 75°°C (167°°F)
AMPACITY CORRECTION FACTORS
Overall ampere ratings of UL Listed Milbank multiple position meter sockets are based on 1993N.E.C. Manual article 220-32 and ANSI / UL-414 (except where restricted by line connector size.)These requirements provide for a diversity factor / demand factor being utilized in determining the over-all (main bus / lug) rating of a gang socket. All Milbank UL Listed gang sockets meet or exceed thesediversity factor/demand factor requirements. Standard overall ampacity ratings for UL Listed and nonUL Listed gang sockets are as shown in the chart below. Ampere ratings of meter sockets are basedon the meter socket being wired with 75° C insulated wire conductor, sized in accordance with Table310-16 of the National Electric Code.
NO. OF METERPOSITIONS
100A / POS.AMPACITY
125A / POS.AMPACITY
150A / POS.AMPACITY
200A / POS.AMPACITY
23456
200A200A200A225A270A
200A225A250A285A330A
200A225A270A338A396A
200A270A360A450A528A
MAXIMUM NUMBER OF CONDUCTORS IN CONDUIT*
A = Size: AWG/MCMB = Ampere Rating forInsulation Types:
FEPW, RH, RHW,THW, THWN, XHHW,
USE, 2W.C = Ampere Rating forInsulation Types:
RH, RHW, THW,THWN, XHHW, USE
(Per NEC table 310-16)
� Unless otherwise permitted elsewhere in the Code, the overcurrent protection for conductor types marked with an obelisk (�) shall not exceed 15amps for 14 AWG, 20 amps for 12 AWG, and 30 amps for 10 AWG copper: or 15 amps for 12 AWG and 25 amps for 10 AWG aluminum andcopper-clad aluminum after any correction factors for ambient temperature and number of conductors have been applied.
All meter sockets are 600 Volt rated unless otherwise noted.All meter socket ampacity ratings are continuous duty unless otherwise noted.
GANG SOCKET OVERALL AMPACITIES
ENERGIZATION OF ELECTRICAL EQUIPMENT18EN
ERG
IZA
TIO
N O
F EL
ECTR
ICA
L EQ
UIP
MEN
T
18
BEFORE ENERGIZING
IMPORTANT NOTE
WHEN ENERGIZING
AFTER ENERGIZING
A. Give equipment a thorough visual examination to determine that:1) No shipping or installation damage exists.2) Proper clearances have been maintained.3) All connections have been made.4) Equipment is clean and dry.
B. Make a thorough examination to:1) Verify tightness of all bolted connections (see table below).2) Manually operate all circuit breakers, switches, relays, etc.3) Check rigidity of all mountings, bus bars and components.4) Use test equipment to check continuity of circuitry and integrity of insulation.
C. All switches and circuit breakers should be in the “off” position.D. Verify that manual meter bypass (if applicable) is in non-bypass position.E. Install cover and/or close doors.F. If installation is not being energized at this time, follow “after-energizing” steps listed below. These
steps will secure the installation in case of accidental energization.
A. Use caution and follow established safety procedures:1) Wear safety apparel.2) Use safety equipment.3) Take action to prevent injury to yourself and others in the event of failure of the installation.4) Take action to prevent/decrease damage to property in the event of failure of the installation.5) If you are unsure how to safely energize the installation, get someone who is knowledgeable to do it.
A. Secure the installation:1) To prevent accidental contact with energized parts, cover all openings with approved filler devices.2) To prevent unauthorized access, secure all covers and/or doors with approved security devices.3) Attach/post information to advise others of potential hazards associated with the installation.
NOMINALSIZE
10
10
10
12
12
1/4
1/4
5/16
JOINT DESCRIPTION
SCREW NUTBRASS
STEEL
STEEL
STEEL
STEEL
STEEL
STEEL
STEEL
Brass Nut or Extruded Hole
CU or AL Busbar <1/8″Steel Nut or EH; CU or AL Busbar >1/8″
Aluminum Extruded Hole
Steel Nut or Extruded Hole
Aluminum Extruded Hole
Steel Nut or EH; CU or AL Busbar
Aluminum Extruded Hole
ALL
ALL
ALL
ALL
ALL
ALL
ALL
HEX
20-25 in. lbs.
25-30 in. lbs
30-35 in. lbs
30-35 in. lbs
40-50 in. lbs.
40-50 in. lbs.
50-60 in. lbs.
60-70 in. lbs.
5/16 STEEL Steel Nut or EH; CU or AL Busbar HEX 100-150 in. lbs.
3/8 STEEL Steel Nut HEX 150-200 in. lbs.
1/2 STEEL Steel Nut HEX 200-250 in. lbs.
HEAD TYPE TORQUE( INCH LBS. )
*Interior labels typically indicate the required torque for wire connectors and studs, and should be referenced first.EH: Extruded HoleCU: CopperAL: Aluminum
RECOMMENDED TORQUE FOR GENERAL APPLICATIONS*
In addition to national and local electrical codes, many utilities have specific requirements for metering equip-ment. Always consult the serving utility for their specifications and requirements prior to ordering or installingMilbank meter mounting equipment.
19A
DD
ITION
AL M
ILBA
NK
PRO
DU
CTS
ADDITIONAL MILBANK PRODUCTS
19
In addition to your local utility’s meter mountingequipment, Milbank also manufactures
supporting products, such as...
Air Conditioner DisconnectsHot Tub Disconnects
RV/Mobile Home Power OutletsTerminal Boxes
Temporary Power OutletsCommercial PedestalsCommercial Enclosures
CT EnclosuresCircuit Breakers
Distribution Unit SubstationsEnclosed Circuit Breakers
Safety SwitchesTest Switches
Contact your local distributor or go towww.milbankmfg.com
to find additional product literature.
Other quality products available from Milbank
Meter Mounting Equipment & More!Commercial Electrical Enclosures
Residential & Commercial Metering
Commercial Meter Pedestals
Disconnect Devices
Current Transformer Enclosures
RV/MH Pedestals
Temporary Power Outlets
Circuit Breakers
Distribution Unit Substations
Enclosed Circuit Breakers
Safety Switches
Test Switches