metalux 22rln 2' x 2' led specification grade troffer with ... · pdf filemetalux...

5
Metalux SPECIFICATION FEATURES Construction Rigid housing is die formed of code gauge prime cold rolled steel and features full length die-formed stiffeners and unibody endplate for added strength. Side flanges are hemmed. Innovative design provides superior lens brightness uniformity and visual comfort. Unibody endplates are securely attached with interlocking tabs and screws. Four auxiliary fixture end suspension points provided. Ample KOs are provided for continuous row wiring. Endplates have integral Grid-lock feature for safety and convenience. Controls The RLN LED is Powered by Fifth Light, with a standard 0-10V continuous dimming driver that works with any 0-10V control/ dimmer. Combine with energy saving products like occupancy sensors, daylighting controls and lighting relay panels to maximize energy savings. In addition, the RLN can include a factory-installed integrated sensor system for occupancy and daylight dimming control and manual control from an optional handheld remote. Or, specify the Digital Addressable Lighting Interface (DALI) drivers, dimmable down to 10%, for use with Fifth Light controls. See ordering information for details on all three options. Electrical Long-Life LED system coupled with electrical driver to deliver optimal performance. LED’s available in 3000K, 3500K or 4000K with a minimum CRI of 80. Projected life is 60,000 hours at 94% lumen output. cULus listed. Electronic drivers are available for 120-277V applications. Emergency Battery Pack Option Optional 120V-277V integral emergency battery pack is available in 7-watts or 14-watts to meet critical life-safety lighting requirements. The 90-minute batteries provide constant power to the LED system, ensuring code- compliance. A test switch/indicator button can be tested safely from the ground using a laser pointer, while the patented EZ Key prevents accidental discharge of the battery during construction. See ordering information for details. Finish Multistage, iron phosphate pretreatment ensures maximum bonding and rust inhibition. Housing and ballast cover finished with new 90% reflective white enamel for superior performance. Hinging/Latching Positive cam action steel latches with baked white enamel finish. Safety-lock T-hinges allow hinging and latching either side. Door assembly hinges down for easy access from below without tools. Frame/Sheilding Die formed, heavy gauge, flat steel door with reinforced mitered corners and painted after fabrication, baked matte white enamel finish. Positive light seals. Acrylic frosted lens. Compliance Modules are UL recognized components and indoor luminaires are cULus listed for 25ºC ambient environments, RoHS compliant, and LED modules comply with IESNA LM-79 and LM-80 standards. DesignLights Consortium ® Qualified and classified for DLC Standard, refer to www. designlights.org for details. Warranty Five year warranty. RLN blends modern styling with an innovative optical design. This contemporary, high quality luminaire provides superior visual comfort and is dedicated to the latest solid-state lighting and driver technology for optimal performance and energy efficiency. The RLN is compatible with all of today’s popular ceiling systems and is available with a number of options and accessories for application versatility. The RLN series features efficiency, quality and performance. The series is an excellent choice for commercial office spaces, schools, hospitals or retail merchandising areas. DESCRIPTION CERTIFICATION DATA cULus 1598 Damp Location Listed IC Rated LM79/LM80 Compliant ROHS Compliant DesignLights Consortium® Qualified Catalog # Type Date Project Comments Prepared by PS519128EN 10-10-2017 22RLN LED 2' X 2' TROFFER LED MODULE Specification Grade Troffer Rectilinear Shielding 23-3/4" [603mm] 3-1/4" [83mm] RECTILINEAR Safe and convenient means of disconnecting power RLN Fl at, White Steel DOOR FRAMES 23-3/4" [603mm] 23-3/4" [603mm] MOUNTING DATA

Upload: vuminh

Post on 06-Mar-2018

251 views

Category:

Documents


9 download

TRANSCRIPT

Page 1: Metalux 22RLN 2' x 2' LED Specification Grade Troffer with ... · PDF fileMetalux SPECIFICATION FEATURES Construction Rigid housing is die formed of code gauge prime cold rolled steel

Metalux

SPECIFICATION FEATURES

ConstructionRigid housing is die formed of code gauge prime cold rolled steel and features full length die-formed stiffeners and unibody endplate for added strength. Side flanges are hemmed. Innovative design provides superior lens brightness uniformity and visual comfort. Unibody endplates are securely attached with interlocking tabs and screws. Four auxiliary fixture end suspension points provided. Ample KOs are provided for continuous row wiring. Endplates have integral Grid-lock feature for safety and convenience.

ControlsThe RLN LED is Powered by Fifth Light, with a standard 0-10V continuous dimming driver that works with any 0-10V control/ dimmer. Combine with energy saving products like occupancy sensors, daylighting controls and lighting relay panels to maximize energy savings. In addition, the RLN can include a factory-installed integrated sensor system for occupancy and daylight dimming control and manual control from an optional handheld remote. Or, specify the Digital Addressable Lighting Interface (DALI) drivers, dimmable down to 10%, for use with Fifth Light controls. See ordering information for details on all three options.

ElectricalLong-Life LED system coupled with electrical driver to deliver optimal performance. LED’s available in 3000K, 3500K or 4000K with a minimum CRI of 80. Projected life is 60,000 hours at 94% lumen output. cULus listed. Electronic drivers are available for 120-277V applications.

Emergency Battery Pack OptionOptional 120V-277V integral emergency battery pack is available in 7-watts or 14-watts to meet critical life-safety lighting requirements. The 90-minute batteries provide constant power to the LED system, ensuring code-compliance. A test switch/indicator button can be tested safely from the ground using a laser pointer, while the patented EZ Key prevents accidental discharge of the battery during construction. See ordering information for details.

FinishMultistage, iron phosphate pretreatment ensures maximum bonding and rust inhibition. Housing and ballast cover finished with new 90% reflective white enamel for superiorperformance.

Hinging/LatchingPositive cam action steel latches with baked white enamel finish. Safety-lock T-hinges allow hinging and latching either side. Door assembly hinges down for easy access from below without tools.

Frame/SheildingDie formed, heavy gauge, flat steel door with reinforced mitered corners and painted after fabrication, baked matte white enamel finish. Positive light seals. Acrylic frosted lens.

ComplianceModules are UL recognized components and indoor luminaires are cULus listed for 25ºC ambient environments, RoHS compliant, and LED modules comply with IESNA LM-79 and LM-80 standards. DesignLights Consortium® Qualified and classified for DLC Standard, refer to www.designlights.org for details.

WarrantyFive year warranty.

RLN blends modern styling with an innovative optical design. This contemporary, high quality luminaire provides superior visual comfort and is dedicated to the latest solid-state lighting and driver technology for optimal performance and energy efficiency. The RLN is compatible with all of today’s popular ceiling systems and is available with a number of options and accessories for application versatility.

The RLN series features efficiency, quality and performance. The series is an excellent choice for commercial office spaces, schools, hospitals or retail merchandising areas.

DESCRIPTION

C E R T I F I C A T I O N D A T A

cULus 1598

Damp Location Listed

IC Rated

LM79/LM80 Compliant

ROHS Compliant

DesignLights Consortium® Qualified

Catalog # Type

Date

Project

Comments

Prepared by

PS519128EN10-10-2017

22RLNLED

2 ' X 2 ' T R O F F E R L E D M O D U L E

Spec i f i ca t ion Grade Trof ferRect i l inear Shie ld ing

23-3/4" [603mm]

3-1/4"[83mm]

RECTILINEAR

Safe and convenient means of disconnecting power

R L NF la t , W h it e St e e l

DOOR FRAMES

23-3/4"[603mm]

23-3/4" [603mm]

MOUNTING DATA

Page 2: Metalux 22RLN 2' x 2' LED Specification Grade Troffer with ... · PDF fileMetalux SPECIFICATION FEATURES Construction Rigid housing is die formed of code gauge prime cold rolled steel

Specifications and dimensions subject to change without notice.

Eaton 1121 Highway 74 SouthPeachtree City, GA 30269P: 770-486-4800www.eaton.com/lighting

22RLN LED RECTILINEAR SHIELDING

Ceiling TrimType TypeExposed Grid GConcealed T GSlot Grid G

(Verify compatibility/ consultfactory.)

GGrid/Lay-inStandard

GConcealed T

GSlot Grid

CEILING COMPATIBILITY

ENERGY AND PERFORMANCE DATA BY CATALOG NUMBER

Ambient Temperature

TM-21 LumenMaintenance

(60,000 hours)

TheoreticalL70

(Hours)

25°C > 94% > 368,000

LUMEN MAINTENANCE

PS519128EN10-10-2017

Stock orMTO*

Catalog Logic (Rectilinear Shielding)

DeliveredLumens

WattsEfficacy(lm/W)

MTO 22RLN-LD5-20-UNV-L830-CD1-U 1935 16.43 118

MTO 22RLN-LD5-20-UNV-L835-CD1-U 2016 16.43 123

MTO 22RLN-LD5-20-UNV-L840-CD1-U 2016 16.43 123

MTO 22RLN-LD5-25-UNV-L830-CD1-U 2441 20.9 117

STOCK 22RLN-LD5-25-UNV-L835-CD1-U 2543 20.9 122

STOCK 22RLN-LD5-25-UNV-L840-CD1-U 2543 20.9 122

MTO 22RLN-LD5-31-UNV-L830-CD1-U 3029 26.6 114

MTO 22RLN-LD5-31-UNV-L835-CD1-U 3155 26.6 119

MTO 22RLN-LD5-31-UNV-L840-CD1-U 3155 26.6 119

MTO 22RLN-LD5-35-UNV-L830-CD1-U 3416 30.57 112

STOCK 22RLN-LD5-35-UNV-L835-CD1-U 3558 30.57 116

STOCK 22RLN-LD5-35-UNV-L840-CD1-U 3558 30.57 116

MTO 22RLN-LD5-40-UNV-L830-CD1-U 3882 35.6 109

MTO 22RLN-LD5-40-UNV-L835-CD1-U 4044 35.6 114

MTO 22RLN-LD5-40-UNV-L840-CD1-U 4044 35.6 114

MTO 22RLN-LD5-44-UNV-L830-CD1-U 4238 39.62 107

MTO 22RLN-LD5-44-UNV-L835-CD1-U 4415 39.62 111

MTO 22RLN-LD5-44-UNV-L840-CD1-U 4415 39.62 111

*Made to order (MTO) requires a typical four week lead time.

Lumen Adjustment Factors 80->90 CRI

Example of LumenAdjustment Calculation

3000K

3500K

4000K

0.865

0.861

0.883

22RLN-LD5-25-UNV-L935-CD1-Uat 90CRI at 3500K

Lumen Adjustment Factor = 0.861

Total Light Output =2,543 lm x 0.861 = 2,190 lm

Efficacy = = 104.8 lm/W2,190 lm20.9 W

5000K n.a.

90 CRI

Page 3: Metalux 22RLN 2' x 2' LED Specification Grade Troffer with ... · PDF fileMetalux SPECIFICATION FEATURES Construction Rigid housing is die formed of code gauge prime cold rolled steel

Specifications and dimensions subject to change without notice.

Eaton 1121 Highway 74 SouthPeachtree City, GA 30269P: 770-486-4800www.eaton.com/lighting

PHOTOMETRICS

22RLN LED RECTILINEAR SHIELDING

PS519128EN10-10-2017

22RLN-LD5-25-UNV-L835-CD1-U

Electronic Driver

Linear LED 3500K

Spacing criterion: (II) 1.19 x mounting height, (⊥) 1.23 x mounting height

Lumens: 2542.9

Input Watts: 20.9W

Efficacy: 121.7 lm/W

Test Report: 22RLN-LD5-25-UNV-L835-CD1-U.IES

051015202530354045505560657075808590

C a n d l e p owe r

Angle Along II 45° Across ⊥

994 994 994986 990 994967 974 980938 946 956897 910 922847 861 878789 804 824723 739 761655 668 689586 593 613511 518 534438 440 451363 361 369292 283 286 219 209 208151 139 13589 77 7436 27 230 0 0

C o e f f i c i e n t s o f U t i l i z a t i o n

Effective floor cavity reflectance 20%

rc 80% 70% 50% 30% 10% 0%rw 70 50 30 10 70 50 30 10 50 30 10 50 30 10 50 30 10 0

RCR0123456789

10

119 119 119 119 116 116 116 116 111 111 111 106 106 106 102 102 102 100109 105 101 97 107 102 99 95 98 95 92 94 92 90 91 89 87 85100 92 85 80 97 90 84 79 86 81 77 83 79 75 80 77 73 7191 81 73 67 89 79 72 66 76 70 65 74 68 64 71 67 63 6184 72 63 57 81 71 63 56 68 61 56 66 60 55 64 58 54 5277 64 56 49 75 63 55 49 61 54 48 59 53 48 57 52 47 4571 58 49 43 69 57 49 43 55 48 43 54 47 42 52 46 42 4066 53 44 38 64 52 44 38 51 43 38 49 42 38 48 42 37 3562 48 40 34 60 48 40 34 46 39 34 45 38 34 44 38 33 3258 44 36 31 56 44 36 31 43 36 31 42 35 30 41 35 30 2854 41 33 28 53 41 33 28 40 33 28 39 32 28 38 32 28 26

Z o n a l L u m e n S u m m a r y

Zone Lumens % Fixture0-30

0-40

0-60

0-90

0-180

758 29.8

1220 48.0

2075 81.6

2543 100.0

2543 100.0

L u m i n a n c e Da t a

Anglein Deg

Average0-Degcd/sm

Average45-Degcd/sm

Average90-Degcd/sm

4555657585

2654 2686 27762446 2457 25182213 2144 21671868 1720 16701323 992 845

249

0˚ 30˚

40˚

50˚

70˚

90˚

20˚

80˚

60˚499

748

997

10˚

22RLN-LD5-35-UNV-L835-CD1-U

Electronic Driver

Linear LED 3500K

Spacing criterion: (II) 1.19 x mounting height, (⊥) 1.23 x mounting height

Lumens: 3558.3

Input Watts: 30.6W

Efficacy: 116.3 lm/W

Test Report: 22RLN-LD5-35-UNV-L835-CD1-U.IES

051015202530354045505560657075808590

C a n d l e p owe r

Angle Along II 45° Across ⊥

1393 1393 13931381 1386 13921356 1363 13721315 1326 13391255 1274 12881186 1205 12281107 1126 11501017 1032 1061920 935 962817 833 855718 722 744613 614 633509 504 515408 399 402303 293 293213 194 192124 109 10252 37 320 0 0

C o e f f i c i e n t s o f U t i l i z a t i o n

Effective floor cavity reflectance 20%

rc 80% 70% 50% 30% 10% 0%rw 70 50 30 10 70 50 30 10 50 30 10 50 30 10 50 30 10 0

RCR0123456789

10

119 119 119 119 116 116 116 116 111 111 111 106 106 106 102 102 102 100109 105 101 97 107 102 99 95 98 95 92 94 92 90 91 89 87 85100 92 85 80 97 90 84 79 86 81 77 83 79 75 80 77 73 7191 81 73 67 89 79 72 66 76 70 65 74 68 64 71 67 63 6184 72 63 57 81 71 63 56 68 61 56 66 60 55 64 58 54 5277 64 56 49 75 63 55 49 61 54 48 59 53 48 57 52 47 4571 58 49 43 69 57 49 43 55 48 43 54 47 42 52 46 42 4066 53 44 38 64 52 44 38 51 43 38 49 42 38 48 42 37 3562 48 40 34 60 48 40 34 46 39 34 45 38 34 44 38 33 3258 44 36 31 56 44 36 31 43 36 31 42 35 30 41 35 30 2954 41 33 28 53 41 33 28 40 33 28 39 32 28 38 32 28 26

Z o n a l L u m e n S u m m a r y

Zone Lumens % Fixture0-30

0-40

0-60

0-90

0-180

1061 29.8

1709 48.0

2903 81.6

3558 100.0

3558 100.0

L u m i n a n c e Da t a

Anglein Deg

Average0-Degcd/sm

Average45-Degcd/sm

Average90-Degcd/sm

4555657585

3700 3773 38723423 3428 35343092 3024 30462636 2400 23761911 1360 1176

349

0˚ 30˚

40˚

50˚

70˚

90˚

20˚

80˚

60˚699

1048

1397

10˚

Page 4: Metalux 22RLN 2' x 2' LED Specification Grade Troffer with ... · PDF fileMetalux SPECIFICATION FEATURES Construction Rigid housing is die formed of code gauge prime cold rolled steel

Specifications and dimensions subject to change without notice.

Eaton 1121 Highway 74 SouthPeachtree City, GA 30269P: 770-486-4800www.eaton.com/lighting

A C C E S S O R I E SEQ-CLIP-U=T-BAR Safety Earthquake Clips (1)

DF-22-W=2' x 2' Drywall Frame KitDF10P-C =Decorator Dimmer, 0-10VSF10P- =Decorator Slide Dimmer, 0-10VSK-22-WS=Field Install Surface Mount Kit, ShallowSK-22-WT=Field Install Surface Mount Kit, TallISHH-01=Programming Remote for Integrated SensorISHH-02=Personal Control Remote for Integrated Sensor

S A M P L E N U M B E R : 2 2 R L N - L D 5 - 3 5 - U N V - L 8 3 5 - C D 1 - U

Voltage (2)

347V=347 Volt (8)

UNV=UniversalVoltage 120-277

Number of Drivers1=1 Driver

Door FrameStandard=Flat White SteelDoor (Leave Blank)

RatingBlank=StandardATW-SW4=ChicagoRated

Series (7)

22RLN=2x2 RLN Series

Lamp TypeLD5=LED 5.0

Shielding

OptionsEmergencyEL7W=7-watt, 120V-277V emergency battery pack installed (3)

EL14W=14-watt 120V-277V emergency battery pack installed (3)

GTD2=Bodine Generator Transfer Device (9)

ETS2=IOTA Emergency Transfer Switch (9)

Flex (5)

Multiple Configurations Available

Blank=Standard LensRDP=Rectilinear with Round Pattern Insert

Driver TypeCD=0-10V Dimming Driver(10% - 100% Dimming)HCD=0-10V Dimming Driver(1% - 100% Dimming)SD=Step-Dim Driver

(6)

5LTD=Fifth Light DALI Driver(10% - 100% Dimming) (4), (6)

SR=Sensor Ready (1% to 100% dimming)

(11)

PackagingU=Unit PackPALC=JobPack, in carton

Stock Lumen Output25=2500 Lumen35=3500 Lumen

MTO Lumen Output20=2000 Lumen31=3100 Lumen40=4000 Lumen44=4400 Lumen

NOTES: (1)An EQ Grid Clip is recommended for all 9/16" ceiling systems. Four required per fixture. (2)Products also available in non-US voltages and frequencies for international markets. (3)With integral test switch/indicator/laser test. For approximate delivered lumens multiply the lumens per watt of the desired fixture by the wattage of the emergency battery pack (100 lm/W x 7=700 lumens). IES-format photometry for luminaire under emergency operation available. (4)Must be used in conjunction with a DALI control system. For complete DALI solutions by Fifth Light visit www.eaton.com/lightingsystems. (5)Flex does not include dimming leads. Control leads provided by others. (6)2000, 2500,3100 and 3500 Lumen packages not available with Step- Dim (SD) and Fifth Light (5LTD) driver option. (7) DesignLights Consortium® Qualified and classified for DLC Standard/Premium (all lumen packages), refer to www.designlights.org for details. (8) 347V versions are not available with emergency options. (9) Used to transfer fixture to secondary power source for life-safety operation. When used with a dimming fixture, two devices are required to ensure control is disabled while operating under emergency power. (10) Integral sensors work with CD and HCD drivers only and is factory prewired to the driver for stand-alone control. (11) SR driver compatible with LWI option only. (12) LWT compatible with CD and HCD drivers only. (13) LWT sensor is external to luminaire, cable factory wired. Must be used in conjunction with a LumaWatt Pro control system. For complete LumaWatt Pro wireless solutions, visit www.eaton.com/lumawattpro Specifications & dimensions subject to change without notice. Consult your Eaton Representative for availability and ordering information.

Integrated SolutionsS=Integrated Sensor (10)

L=LumaWatt

Control TypeV=Analog (0-10V) Output for Local Control (10)

W=WaveLinx (10)

WI=Wireless Integral (11)

WT=Wireless Tile (12), (13)

Occupancy TechnologyP=Passive Infrared

Sensing TechnologyD=Dimming Daylight Harvesting (Closed Loop)

Coverage Pattern1= ~144 Square Feet

CCT

L930=3000KL935=3500KL940=4000K

L830=3000KL835=3500KL840=4000K

ORDERING INFORMATION

Catalog No. Wt.

22RLN-LD5-25 10 lbs.

22RLN-LD5-35 10 lbs.

SHIPPING DATA

22RLN LED RECTILINEAR SHIELDING

PS519128EN10-10-2017

Page 5: Metalux 22RLN 2' x 2' LED Specification Grade Troffer with ... · PDF fileMetalux SPECIFICATION FEATURES Construction Rigid housing is die formed of code gauge prime cold rolled steel

Specifications and dimensions subject to change without notice.

Eaton 1121 Highway 74 SouthPeachtree City, GA 30269P: 770-486-4800www.eaton.com/lighting

INTEGRATED SENSOR

22RLN LED RECTILINEAR SHIELDING

PS519128EN10-10-2017

The RLN with Integrated Sensor technology provides automatic energy savings without sacrificing performance. Traditionally, these types of energy savings required coordination between the luminaire and a lighting control system. The RLN delivers superior lighting with integrated occupancy and daylighting controls.

Capture the benefits of traditional lighting controls, without complicated coverage planning or special wiring. Ideal for new construction or retrofit, the RLN delivers automatic ON to an energy saving light level, while ensuring lighting is turned OFF when the space is unoccupied.

The integral daylight sensor reduces the need for special daylight zone planning. Each luminaire will automatically adjust the light level based on reflected light beneath the sensor in a closed loop method.

Occupied daylight light levels and unoccupied light levels can be adjusted using the integrated sensor programming remote (Catalog Number: ISHH-01). The integrated sensor personal remote (Catalog Number: ISHH-02) provides code compliant manual raise, lower, ON, OFF control.

The RLN with Integrated Sensor is easy to install with no special wiring and ensures energy savings out-of-the-box with default control settings.

How it works:

• As the user enters the space controlled by the integral sensor, the lighting turns ON to the default daylight level.

• Lighting will remain at that the daylight level until the space is unoccupied. This will start the occupancy timeout period (default 20 minutes).

• If the space remains unoccupied for half of the timeout period, the lighting will automatically reduce to the Energy Saver light level. This adjustable light level is typically half of the occupied daylight level.

• At the end of the timeout period the lighting will go to the unoccupied light level. This adjustable light level uses the OFF default setting.

Optional RemoteControl

ISHH-01 Remote

CL

Top View Side View

4m[12 ft.]

4m[12 ft.]

0m[0 ft.]

Coverage

Major Motion

3.3m[10 ft.]

0m[0 ft.]

0m[0 ft.]

4m[12 ft.]

4m[12 ft.]

Reccomended Mounting Height 8–12 ft.

Programming Remote

ISHH-01

To Set Output

1. Raise, Lower or Press Min.

50, 75, Max.

2. To save press SET

3. Select Occ or Un Occ

Raise/Lower

TimeOut5

10

15

20

HI

LO

ES

SET

Occ

50

MIN

UnOcc

MAX

75

100

0

Lig

ht

Leve

l (DO)Daylight Level

(DO)Daylight Level

Timeout Value

(ES)Energy SaverLight Level

OccupiedUnoccupiedOccupiedUnoccupied

Energy SavingsOpportunities

(DU)Unoccupied Level

Target light level default: 500 lux at 8 ft.