metal covering at eave - huber engineered...
TRANSCRIPT
07-09-2012
Telephone: 800.933.9220 - Facsimile: 704.547.9228 - www.zipsystem.comSales Office: 10925 David Taylor Drive - Suite 300 - Charlotte, NC 28262
DRAWING NOT TO SCALE
These construction details are provided to assist in the installation of ZIP System product(s) and may not apply to
every stituation. Manufacturer accepts no responsibility or liability for the use of these or other construction details.
ZIP SYSTEM® SHEATHING-ROOF WITHMETAL COVERING AT EAVE A-1
ICE DAM PROTECTION AS
PRESCRIBED BY LOCAL
BUILDING CODE.
1/8-INCH GAP RECOMMENDED AT
PANEL EDGES UNLESS
OTHERWISE PROVIDED BY
MACHINED PROFILED EDGES
ROOF ASSEMBLY
METAL ROOF COVERING
ZIP SYSTEM SHEATHING
ROOF TRUSS
SOFFIT VENT
07-09-2012
Telephone: 800.933.9220 - Facsimile: 704.547.9228 - www.zipsystem.comSales Office: 10925 David Taylor Drive - Suite 300 - Charlotte, NC 28262
DRAWING NOT TO SCALE
These construction details are provided to assist in the installation of ZIP System product(s) and may not apply to
every stituation. Manufacturer accepts no responsibility or liability for the use of these or other construction details.
ZIP SYSTEM® ROOF W/ METAL AT EAVE FORBRICK WALL ASSEMBLY A-2
CODE APPROVED FLASHING
TOP EDGE OF FLASHING
TAPED TO WALL SHEATHING
WITH ZIP SYSTEM TAPE OR
ADHESIVE BACKED FLASHING.
(MUST MEET AC148)
CODE APPROVED FLASHING
LAPPED OVER STANDING
SEAM METAL ROOF
WALL ASSEMBLY
VINYL/WOOD/FIBER CEMENT SIDING (INSTALLED IN
ACCORDANCE WITH CLADDING MANUFACTURER'S
INSTALLATION RECOMMENDATIONS)
ZIP SYSTEM SHEATHING
WOOD OR LIGHT GAUGE METAL STUDS
TOP EDGE OF FLASHING TAPED TO
WALL SHEATHING WITH ZIP SYSTEM
TAPE OR ADHESIVE BACKED
FLASHING. (MUST MEET AC148)
ADHESIVE BACKED FLASHING
RECOMMENDED (MUST MEET AC148)
ROOF ASSEMBLY
METAL ROOF COVERING
ROOF UNDERLAYMENT
PLYWOOD OR OSB SHEATHING
ROOF TRUSS OR RAFTERS
ADHESIVE BACKED
FLASHING RECOMMENDED
(MUST MEET AC148)
ROOF UNDERLAYMENT
07-09-2012
Telephone: 800.933.9220 - Facsimile: 704.547.9228 - www.zipsystem.comSales Office: 10925 David Taylor Drive - Suite 300 - Charlotte, NC 28262
DRAWING NOT TO SCALE
These construction details are provided to assist in the installation of ZIP System product(s) and may not apply to
every stituation. Manufacturer accepts no responsibility or liability for the use of these or other construction details.
TYPICAL FELT ROOF W/ METAL INTO ZIPSYSTEM® SHEATHING-WALL ABOVE A-4
CODE APPROVED FLASHING
CODE APPROVED
FLASHING LAPPED
OVER STANDING SEAM
METAL ROOF
ROOF ASSEMBLY
METAL ROOF COVERING
ZIP SYSTEM SHEATHING
ROOF TRUSS OR RAFTER
WALL ASSEMBLY
VINYL/WOOD/FIBER CEMENT SIDING (INSTALLED IN
ACCORDANCE WITH CLADDING MANUFACTURER'S
INSTALLATION RECOMMENDATIONS)
BUILDING PAPER/HOUSEWRAP
PLYWOOD OR OSB SHEATHING
WOOD OR LIGHT GAUGE METAL STUDS
BUILDING PAPER/HOUSEWRAP
ADHESIVE BACKED FLASHING
RECOMMENDED (MUST MEET AC148)
ADHESIVE BACKED
FLASHING RECOMMENDED
(MUST MEET AC148)
BUILDING PAPER/HOUSEWRAP
LAPPED OVER FLASHING
07-09-2012
Telephone: 800.933.9220 - Facsimile: 704.547.9228 - www.zipsystem.comSales Office: 10925 David Taylor Drive - Suite 300 - Charlotte, NC 28262
DRAWING NOT TO SCALE
These construction details are provided to assist in the installation of ZIP System product(s) and may not apply to
every stituation. Manufacturer accepts no responsibility or liability for the use of these or other construction details.
ZIP SYSTEM® SHEATHING-ROOF W/ METALINTO WATER RESISTANT BARRIER WALL ABOVE A-5
ROOF ASSEMBLY
ASPHALT-FIBERGLASS
SHINGLES
ZIP SYSTEM SHEATHING
ROOF TRUSS OR RAFTERS
METAL RIDGE CAP VENT
CUT BACK ZIP SYSTEM
TAPE PRIOR TO
INSTALLATION OF RIDGE
VENT (OPENING SIZE
BASED ON RIDGE VENT
MANUFACTURER'S
RECOMMENDATIONS)
ZIP SYSTEM TAPE
INSTALLED AT RIDGE
FOR TEMPORARY
DRY-IN
07-09-2012
Telephone: 800.933.9220 - Facsimile: 704.547.9228 - www.zipsystem.comSales Office: 10925 David Taylor Drive - Suite 300 - Charlotte, NC 28262
DRAWING NOT TO SCALE
These construction details are provided to assist in the installation of ZIP System product(s) and may not apply to
every stituation. Manufacturer accepts no responsibility or liability for the use of these or other construction details.
ZIP SYSTEM® SHEATHING ROOF WITHMETAL AT RIDGE VENT A-6
FOLLOW SKYLIGHT
MANUFACTURER'S
RECOMMENDED
FLASHING/WATERPROOFING
DETAILS
ROOF ASSEMBLY
METAL ROOF COVERING
ZIP SYSTEM SHEATHING
R
O
O
F
S
L
O
P
E
07-09-2012
Telephone: 800.933.9220 - Facsimile: 704.547.9228 - www.zipsystem.comSales Office: 10925 David Taylor Drive - Suite 300 - Charlotte, NC 28262
DRAWING NOT TO SCALE
These construction details are provided to assist in the installation of ZIP System product(s) and may not apply to
every stituation. Manufacturer accepts no responsibility or liability for the use of these or other construction details.
ZIP SYSTEM® SHEATHING-ROOF WITHMETAL AT SKYLIGHT A-7
1/8-INCH GAP RECOMMENDED AT
PANEL EDGES UNLESS
OTHERWISE PROVIDED BY
MACHINED PROFILED EDGES
.
TOP EDGE OF FLASHING TAPED TO
WALL SHEATHING WITH ZIP SYSTEM
TAPE OR ADHESIVE BACKED
FLASHING. (MUST MEET AC148)
ZIP SYSTEM TAPE OR ADHESIVE
BACKED FLASHING (MUST MEET
AC148) INSTALLED AT JOINT
BETWEEN ZIP SYSTEM WALL AND
ROOF SHEATHING*
1/8-INCH GAP RECOMMENDED AT
PANEL EDGES UNLESS
OTHERWISE PROVIDED BY
MACHINED PROFILED EDGES
CODE APPROVED
FLASHING
METAL ROOF COVERING -
FASTEN PER CODE USING
FASTENERS COMPATIBLE
WITH SPECIFIC METAL
ROOF COVERING.
WALL ASSEMBLY
ZIP SYSTEM SHEATHING
WOOD OR LT. GA. METAL STUDS
ZIP SYSTEM SHEATHING (ROOF).
07-09-2012
Telephone: 800.933.9220 - Facsimile: 704.547.9228 - www.zipsystem.comSales Office: 10925 David Taylor Drive - Suite 300 - Charlotte, NC 28262
DRAWING NOT TO SCALE
These construction details are provided to assist in the installation of ZIP System product(s) and may not apply to
every stituation. Manufacturer accepts no responsibility or liability for the use of these or other construction details.
ZIP SYSTEM SHEATHING W/ METAL COVERINGAT WALL TO ROOF TRANSITION A-8
ZIP SYSTEM TAPE*
METAL VALLEY FLASHING
METAL ROOF COVERING -
FASTEN PER CODE USING
FASTENERS COMPATIBLE
WITH SPECIFIC METAL
ROOF COVERING.
07-09-2012
Telephone: 800.933.9220 - Facsimile: 704.547.9228 - www.zipsystem.comSales Office: 10925 David Taylor Drive - Suite 300 - Charlotte, NC 28262
DRAWING NOT TO SCALE
These construction details are provided to assist in the installation of ZIP System product(s) and may not apply to
every stituation. Manufacturer accepts no responsibility or liability for the use of these or other construction details.
ZIP SYSTEM® SHEATHING-ROOF W/ METAL W/CRIMPED VALLEY FLASHING A-9
ZIP SYSTE TAPE*
METAL VALLEY FLASHING
ZIP SYST TAPE OR ADHESIVE
BACKED FLASHING (MUST MEET AC148)
LAPPED OVER METAL VALLEY FLASHING
METAL ROOF COVERING -
FASTEN PER CODE USING
FASTENERS COMPATIBLE
WITH SPECIFIC METAL
ROOF COVERING.
07-09-2012
Telephone: 800.933.9220 - Facsimile: 704.547.9228 - www.zipsystem.comSales Office: 10925 David Taylor Drive - Suite 300 - Charlotte, NC 28262
DRAWING NOT TO SCALE
These construction details are provided to assist in the installation of ZIP System product(s) and may not apply to
every stituation. Manufacturer accepts no responsibility or liability for the use of these or other construction details.
ZIP SYSTEM® SHEATHING-ROOF WITH METALWITH FLAT VALLEY FLASHING A-10
LAP LOWER PANEL OF METAL
ROOF UNDER PREFORMED METAL
ROOF VENT
METAL ROOF COVERING - FASTEN
PER CODE USING FASTENERS
COMPATIBLE WITH SPECIFIC
METAL ROOF COVERING.
UPPER METAL ROOF PANEL CUT
TO FIT AROUND PREFORMED
METAL ROOF VENT
07-09-2012
Telephone: 800.933.9220 - Facsimile: 704.547.9228 - www.zipsystem.comSales Office: 10925 David Taylor Drive - Suite 300 - Charlotte, NC 28262
DRAWING NOT TO SCALE
These construction details are provided to assist in the installation of ZIP System product(s) and may not apply to
every stituation. Manufacturer accepts no responsibility or liability for the use of these or other construction details.
ZIP SYSTEM® SHEATHING-ROOF WITHMETAL AT PLUMBING VENT A-11
LAP ZIP SYSTEM TAPE OR
ADHESIVE BACKED FLASHING.
(MUST MEET AC148) OVER TOP
OF CONTINUOUS FLASHING
CODE-APPROVED FLASHING
AT ROOF TO CHIMNEY
INTERSECTION
1/8-INCH GAP RECOMMENDED AT PANEL
EDGES UNLESS OTHERWISE PROVIDED
BY MACHINED PROFILED EDGES
INSTALL ZIP SYSTEM
TAPE ON ALL JOINTS OF
CHIMNEY CRICKET
METAL ROOF COVERING - FASTEN PER
CODE USING FASTENERS COMPATIBLE
WITH SPECIFIC METAL ROOF COVERING
FLASHING PER MANUFACTURER'S
INSTALLATION INSTRUCTIONS
ZIP SYSTE SHEATHING ON
WOOD-FRAMED CHIMNEY FLUE
07-09-2012
Telephone: 800.933.9220 - Facsimile: 704.547.9228 - www.zipsystem.comSales Office: 10925 David Taylor Drive - Suite 300 - Charlotte, NC 28262
DRAWING NOT TO SCALE
These construction details are provided to assist in the installation of ZIP System product(s) and may not apply to
every stituation. Manufacturer accepts no responsibility or liability for the use of these or other construction details.
ZIP SYSTEM® SHEATHING-ROOF WITH METALINTO ZIP-WALL AT CHIMNEY A-12
ZIP SYSTEM SHEATHING ON
WOOD-FRAMED CHIMNEY
FLUE
FLASHING PER MANUFACTURER'S
INSTALLATION INSTRUCTIONS
METAL ROOF COVERING - FASTEN PER
CODE USING FASTENERS COMPATIBLE
WITH SPECIFIC METAL ROOF COVERING
07-09-2012
Telephone: 800.933.9220 - Facsimile: 704.547.9228 - www.zipsystem.comSales Office: 10925 David Taylor Drive - Suite 300 - Charlotte, NC 28262
DRAWING NOT TO SCALE
These construction details are provided to assist in the installation of ZIP System product(s) and may not apply to
every stituation. Manufacturer accepts no responsibility or liability for the use of these or other construction details.
ZIP SYSTEM® ROOF W/ METAL INTO ZIP-WALLAT CHIMNEY (ROOF EDGE) A-13