met one 7000 series remote airborne particle counters customer name date presenter presenter title
TRANSCRIPT
MET ONE 7000 SeriesRemote Airborne Particle Counters
Customer NameDate
PresenterPresenter Title
Copyright 2008 Hach Ultra Analytics – Page 2
MET ONE 7000 Series
Copyright 2008 Hach Ultra Analytics – Page 3
Agenda
• MET ONE 7000 Series Overview• Features and Benefits• Part Numbers
Copyright 2008 Hach Ultra Analytics – Page 4
Introduction to the MET ONE 7000 Series
1. Designed for ISO 21501 compliance, ensures confidence in data accuracy, reliability and repeatability.
2. Flexible communication options and easy installation features allow easy integration of the remote counter with any FMS system.
3. The counter offers the most advanced instrument status and user notification indication feature available in the industry, saving troubleshooting and downtime related costs work.
The MET ONE 7000 Series remote airborne particle counters, designed for ISO 21501 compliance, offers accurate, reliable, consistent and repeatable continuous particle monitoring. With a sensitivity range of 0.3 to 10 µm, the MET ONE 7000 Series is designed to meet the specific needs of cleanroom operations within the aseptic or sterile manufacturing facilities in the Life Science industry.
Copyright 2008 Hach Ultra Analytics – Page 5
Introduction to MET ONE 7000 Series
Service port for instrument set-up Also can be used for optional
remote display unit (future enhancement)
Optional Relative Humidity-Temperature
probe connection
Optional remote indicator light port
Multi-color status indicator LED
• ISO 21501 compliant design
• Multiple I/O option
• Built-in enhanced instrument status and user notification indicator
• Long Life Laser™
• VHP tolerant flow path and optics
• Wall plate, umbilical cords and tubes with quick connect fittings for ease of installation and removal
• Up to 1000 sampling data storage
• 0.3 µm sensitivity, 0.1 or 1.0 cfm flow rate
• Built-in flow sensor option
• Remote status indicator light option Standard 2 channel, optional 4 channel
• Sealed enclosure with sealed connectors
• RH-Temp probe option
• Free set-up utility program
Copyright 2008 Hach Ultra Analytics – Page 6
First Counter Designed With ISO 21501 Compliant Capabilities
ISO 21501 is a new calibration standard replacing ASTM F328 and other similar existing standards
• Accuracy in counting specific particle size
• Significantly improved measurement repeatability from counter to counter
• Reliability in accurate identification of particle sizes of interest that affect product quality and yield
Copyright 2008 Hach Ultra Analytics – Page 7
Flexible Communication Options
Save FMS integration costs, repair and inventory related costs with multiple communications
• Serial I/O (RS-485 with Modbus RTU or FX protocol)
• Ethernet
• Analog
• Wireless
RJ 45 sealed connectorfor Ethernet, RS485 serial or
Analog I/O Makes integration to any FMS easier
Copyright 2008 Hach Ultra Analytics – Page 8
Ease of Installation Features • Easy installation with AC or DC input power options
– 100~230 VAC 50/60 Hz house power– 24 VDC local power network
• Reduces re-installation time during routine calibration and maintenance with DIP switch feature for serial units
• Quick-connect type sealed vacuum connection
AC or DC input power option
Makes installation easier
DIP switch for setting address of
RS485 serial I/O instrument Makes installation and removal easier
Quick connect type vacuum connector
For ease of installation
Copyright 2008 Hach Ultra Analytics – Page 9
Ease of Installation Features • Wall plate for terminating end-user cables
and tubing, reduces disruption to connectivity during routine calibration
• Umbilical with quick connect sealed connectors protect counter from wash down and make reinstallation easy
• Quick-connect type sealed vacuum connection makes reinstallation during routine calibration easy
User terminates wiring, tubing at the rear end of
the wall plateMakes installation easier
Umbilical cords and tubing supplied to
connect the counter with wall plate
For ease of installation and subsequent removal for routine calibration and maintenance. Ensure sealed connections
Wall Plate - Front Makes installation and
removal of counter easier
Copyright 2008 Hach Ultra Analytics – Page 10
Installation Features - Standard Accessories
Item Number
Description
1 MET ONE 7000 Counter
2 Mounting Plate
3, 4 Isokinetic Probe (0.1 or 1.0 cfm)
5 Wall Plate
6 Communication Cable with Sealed RJ-45 Connectors
7 Power Cable AC or DC
8 Vacuum Tubing with Sealed Quick Connectors
• Reduces initial installation time
• Minimizes removal and re-installation time during routine calibration and maintenance
• Provides wash-down tolerance with sealed umbilical and tubing
Copyright 2008 Hach Ultra Analytics – Page 11
Enhanced Instrument Diagnostics
• Instrument can be diagnosed for flow, sensor, communication failures, and count alarm or count alert through built-in or external light indicator
Steady Green = Normal (set by software or internal)
Flashing Red = Count Alarm (set by software or internal)
Flashing Yellow = Count Alert (set by software only)
One short flash, one long flash Blue = Flow Fail (set by software or internal)
Solid Blue = Sensor Fail (set by software or internal)
Flashing Blue (2 Hz) = Communication Failure (internally set based on communication timeout)
• Enhanced instrument status indication reduce troubleshooting time and downtime
Built in or optional remote multi-color status
indicator LED
Copyright 2008 Hach Ultra Analytics – Page 12
MET ONE 7000 Series Setup Utility Program
• Reduce set-up time with the MET ONE 7000 Series setup utility program
– Local Setup– LAN Setup– Data Display
• Reduce troubleshooting time – Run MET ONE 7000 Series remote counters without
FMS software for troubleshooting– Obtain instrument information such as model, serial
number and built in flow sensor
Copyright 2008 Hach Ultra Analytics – Page 13
Local Setup Screen Capture
Copyright 2008 Hach Ultra Analytics – Page 14
LAN Setup Screen Capture
Copyright 2008 Hach Ultra Analytics – Page 15
Data Display Screen Capture
Copyright 2008 Hach Ultra Analytics – Page 16
MET ONE 7000 Feature Summary
Features Benefits
Designed for ISO 21501 calibration capabilityCounter calibrated per ISO 21501 requirements measures particles accurately, reliably and consistently
Flexible communication optionsEasy to integrate with any FMS system due to flexible communication features such as Serial Modbus, Ethernet Analog and Wireless, and optional OPC server feature
Enhanced instrument status and user notification indicator
Additional status indications provide faster troubleshooting and reduces downtime
Long Life Laser Average ~10 years – reduces cost of ownership
Ease of installation, removal and interchangeabilityShorter installation time and flexibility for removal and replacement of counters for routine calibration work
Sealed enclosure and sealed connectors Provides better sealing for use in wash-down areas
Flow Path and optics are VHP tolerantCounter will not be damaged by accidental inclusion of VHP in the sensor flow path during disinfecting process
Increased data storageNo loss of data during accidental communication or computer problem
Hach Ultra MET ONE Brand Quality, performance and service
Copyright 2008 Hach Ultra Analytics – Page 17
MET ONE 7000 Series Monetization
• Reliability in accurate identification of particles due to ISO 21501 compliant design that improves product quality and yield
• Reduced troubleshooting time (labor), and less downtime
• Standardized sensor irrespective of communication systems saving integration cost, repair time, downtime and inventory related costs
• Reduced replacement parts cost and lower overall cost of ownership
• Reduced removal and re-installation cost during routine calibration/maintenance work
• Reduced risk of data loss due to communication disruption
Please use the monetization tab in the value selling document
Copyright 2008 Hach Ultra Analytics – Page 18
MET ONE 7000 Series Part Numbers
How to Order 20887_ 5 - N _ - _ _ -_
0 = DC Type cableB = Type B Power CordD= Type D Power CordE= Type E Power CordG= Type G Power CordJ= Type J Power Cord
D = 24 VDC Input PowerA = 100~230 VAC 50/60 HZ Input Power
A = Analog 4~20 mAE = EthernetS = Serial RS485
F = with flow measurementN = without flow measurement
N = No Built-in Pump
5 = 0.5µm Minimum sensitivity
0 = 0.1 cfm 1 = 1.0 cfm
208871 5 - NF - ED - 0 (Example) 208871 5 - NF - SA - B (Example)
Copyright 2008 Hach Ultra Analytics – Page 19
Standard Shipment Includes
Item Number
Description
1 MET ONE 7000 Counter
2 Mounting Plate
3, 4 Isokinetic Probe (0.1 or 1.0 cfm)
5 Wall Plate
6 Communication Cable with Sealed RJ-45 Connectors
7 Power Cable AC or DC
8 Vacuum Tubing with Sealed Quick Connectors
Copyright 2008 Hach Ultra Analytics – Page 20
MET ONE 7000 Series