met one 7000 series remote airborne particle counters customer name date presenter presenter title

20
MET ONE 7000 Series Remote Airborne Particle Counters Customer Name Date Presenter Presenter Title

Upload: britain

Post on 13-Jan-2016

43 views

Category:

Documents


0 download

DESCRIPTION

MET ONE 7000 Series Remote Airborne Particle Counters Customer Name Date Presenter Presenter Title. MET ONE 7000 Series. Agenda. MET ONE 7000 Series Overview Features and Benefits Part Numbers. Introduction to the MET ONE 7000 Series. - PowerPoint PPT Presentation

TRANSCRIPT

Page 1: MET ONE 7000 Series Remote Airborne Particle Counters Customer Name Date Presenter Presenter Title

MET ONE 7000 SeriesRemote Airborne Particle Counters

Customer NameDate

PresenterPresenter Title

Page 2: MET ONE 7000 Series Remote Airborne Particle Counters Customer Name Date Presenter Presenter Title

Copyright 2008 Hach Ultra Analytics – Page 2

MET ONE 7000 Series

Page 3: MET ONE 7000 Series Remote Airborne Particle Counters Customer Name Date Presenter Presenter Title

Copyright 2008 Hach Ultra Analytics – Page 3

Agenda

• MET ONE 7000 Series Overview• Features and Benefits• Part Numbers

Page 4: MET ONE 7000 Series Remote Airborne Particle Counters Customer Name Date Presenter Presenter Title

Copyright 2008 Hach Ultra Analytics – Page 4

Introduction to the MET ONE 7000 Series

1. Designed for ISO 21501 compliance, ensures confidence in data accuracy, reliability and repeatability.

2. Flexible communication options and easy installation features allow easy integration of the remote counter with any FMS system.

3. The counter offers the most advanced instrument status and user notification indication feature available in the industry, saving troubleshooting and downtime related costs work.

The MET ONE 7000 Series remote airborne particle counters, designed for ISO 21501 compliance, offers accurate, reliable, consistent and repeatable continuous particle monitoring. With a sensitivity range of 0.3 to 10 µm, the MET ONE 7000 Series is designed to meet the specific needs of cleanroom operations within the aseptic or sterile manufacturing facilities in the Life Science industry.

Page 5: MET ONE 7000 Series Remote Airborne Particle Counters Customer Name Date Presenter Presenter Title

Copyright 2008 Hach Ultra Analytics – Page 5

Introduction to MET ONE 7000 Series

Service port for instrument set-up Also can be used for optional

remote display unit (future enhancement)

Optional Relative Humidity-Temperature

probe connection

Optional remote indicator light port

Multi-color status indicator LED

• ISO 21501 compliant design

• Multiple I/O option

• Built-in enhanced instrument status and user notification indicator

• Long Life Laser™

• VHP tolerant flow path and optics

• Wall plate, umbilical cords and tubes with quick connect fittings for ease of installation and removal

• Up to 1000 sampling data storage

• 0.3 µm sensitivity, 0.1 or 1.0 cfm flow rate

• Built-in flow sensor option

• Remote status indicator light option Standard 2 channel, optional 4 channel

• Sealed enclosure with sealed connectors

• RH-Temp probe option

• Free set-up utility program

Page 6: MET ONE 7000 Series Remote Airborne Particle Counters Customer Name Date Presenter Presenter Title

Copyright 2008 Hach Ultra Analytics – Page 6

First Counter Designed With ISO 21501 Compliant Capabilities

ISO 21501 is a new calibration standard replacing ASTM F328 and other similar existing standards

• Accuracy in counting specific particle size

• Significantly improved measurement repeatability from counter to counter

• Reliability in accurate identification of particle sizes of interest that affect product quality and yield

Page 7: MET ONE 7000 Series Remote Airborne Particle Counters Customer Name Date Presenter Presenter Title

Copyright 2008 Hach Ultra Analytics – Page 7

Flexible Communication Options

Save FMS integration costs, repair and inventory related costs with multiple communications

• Serial I/O (RS-485 with Modbus RTU or FX protocol)

• Ethernet

• Analog

• Wireless

RJ 45 sealed connectorfor Ethernet, RS485 serial or

Analog I/O Makes integration to any FMS easier

Page 8: MET ONE 7000 Series Remote Airborne Particle Counters Customer Name Date Presenter Presenter Title

Copyright 2008 Hach Ultra Analytics – Page 8

Ease of Installation Features • Easy installation with AC or DC input power options

– 100~230 VAC 50/60 Hz house power– 24 VDC local power network

• Reduces re-installation time during routine calibration and maintenance with DIP switch feature for serial units

• Quick-connect type sealed vacuum connection

AC or DC input power option

Makes installation easier

DIP switch for setting address of

RS485 serial I/O instrument Makes installation and removal easier

Quick connect type vacuum connector

For ease of installation

Page 9: MET ONE 7000 Series Remote Airborne Particle Counters Customer Name Date Presenter Presenter Title

Copyright 2008 Hach Ultra Analytics – Page 9

Ease of Installation Features • Wall plate for terminating end-user cables

and tubing, reduces disruption to connectivity during routine calibration

• Umbilical with quick connect sealed connectors protect counter from wash down and make reinstallation easy

• Quick-connect type sealed vacuum connection makes reinstallation during routine calibration easy

User terminates wiring, tubing at the rear end of

the wall plateMakes installation easier

Umbilical cords and tubing supplied to

connect the counter with wall plate

For ease of installation and subsequent removal for routine calibration and maintenance. Ensure sealed connections

Wall Plate - Front Makes installation and

removal of counter easier

Page 10: MET ONE 7000 Series Remote Airborne Particle Counters Customer Name Date Presenter Presenter Title

Copyright 2008 Hach Ultra Analytics – Page 10

Installation Features - Standard Accessories

Item Number

Description

1 MET ONE 7000 Counter

2 Mounting Plate

3, 4 Isokinetic Probe (0.1 or 1.0 cfm)

5 Wall Plate

6 Communication Cable with Sealed RJ-45 Connectors

7 Power Cable AC or DC

8 Vacuum Tubing with Sealed Quick Connectors

• Reduces initial installation time

• Minimizes removal and re-installation time during routine calibration and maintenance

• Provides wash-down tolerance with sealed umbilical and tubing

Page 11: MET ONE 7000 Series Remote Airborne Particle Counters Customer Name Date Presenter Presenter Title

Copyright 2008 Hach Ultra Analytics – Page 11

Enhanced Instrument Diagnostics

• Instrument can be diagnosed for flow, sensor, communication failures, and count alarm or count alert through built-in or external light indicator

Steady Green = Normal (set by software or internal)

Flashing Red = Count Alarm (set by software or internal)

Flashing Yellow = Count Alert (set by software only)

One short flash, one long flash Blue = Flow Fail (set by software or internal)

Solid Blue = Sensor Fail (set by software or internal)

Flashing Blue (2 Hz) = Communication Failure (internally set based on communication timeout)

• Enhanced instrument status indication reduce troubleshooting time and downtime

Built in or optional remote multi-color status

indicator LED

Page 12: MET ONE 7000 Series Remote Airborne Particle Counters Customer Name Date Presenter Presenter Title

Copyright 2008 Hach Ultra Analytics – Page 12

MET ONE 7000 Series Setup Utility Program

• Reduce set-up time with the MET ONE 7000 Series setup utility program

– Local Setup– LAN Setup– Data Display

• Reduce troubleshooting time – Run MET ONE 7000 Series remote counters without

FMS software for troubleshooting– Obtain instrument information such as model, serial

number and built in flow sensor

Page 13: MET ONE 7000 Series Remote Airborne Particle Counters Customer Name Date Presenter Presenter Title

Copyright 2008 Hach Ultra Analytics – Page 13

Local Setup Screen Capture

Page 14: MET ONE 7000 Series Remote Airborne Particle Counters Customer Name Date Presenter Presenter Title

Copyright 2008 Hach Ultra Analytics – Page 14

LAN Setup Screen Capture

Page 15: MET ONE 7000 Series Remote Airborne Particle Counters Customer Name Date Presenter Presenter Title

Copyright 2008 Hach Ultra Analytics – Page 15

Data Display Screen Capture

Page 16: MET ONE 7000 Series Remote Airborne Particle Counters Customer Name Date Presenter Presenter Title

Copyright 2008 Hach Ultra Analytics – Page 16

MET ONE 7000 Feature Summary

Features Benefits

Designed for ISO 21501 calibration capabilityCounter calibrated per ISO 21501 requirements measures particles accurately, reliably and consistently

Flexible communication optionsEasy to integrate with any FMS system due to flexible communication features such as Serial Modbus, Ethernet Analog and Wireless, and optional OPC server feature

Enhanced instrument status and user notification indicator

Additional status indications provide faster troubleshooting and reduces downtime

Long Life Laser Average ~10 years – reduces cost of ownership

Ease of installation, removal and interchangeabilityShorter installation time and flexibility for removal and replacement of counters for routine calibration work

Sealed enclosure and sealed connectors Provides better sealing for use in wash-down areas

Flow Path and optics are VHP tolerantCounter will not be damaged by accidental inclusion of VHP in the sensor flow path during disinfecting process

Increased data storageNo loss of data during accidental communication or computer problem

Hach Ultra MET ONE Brand Quality, performance and service

Page 17: MET ONE 7000 Series Remote Airborne Particle Counters Customer Name Date Presenter Presenter Title

Copyright 2008 Hach Ultra Analytics – Page 17

MET ONE 7000 Series Monetization

• Reliability in accurate identification of particles due to ISO 21501 compliant design that improves product quality and yield

• Reduced troubleshooting time (labor), and less downtime

• Standardized sensor irrespective of communication systems saving integration cost, repair time, downtime and inventory related costs

• Reduced replacement parts cost and lower overall cost of ownership

• Reduced removal and re-installation cost during routine calibration/maintenance work

• Reduced risk of data loss due to communication disruption

Please use the monetization tab in the value selling document

Page 18: MET ONE 7000 Series Remote Airborne Particle Counters Customer Name Date Presenter Presenter Title

Copyright 2008 Hach Ultra Analytics – Page 18

MET ONE 7000 Series Part Numbers

How to Order 20887_ 5 - N _ - _ _ -_

0 = DC Type cableB = Type B Power CordD= Type D Power CordE= Type E Power CordG= Type G Power CordJ= Type J Power Cord

D = 24 VDC Input PowerA = 100~230 VAC 50/60 HZ Input Power

A = Analog 4~20 mAE = EthernetS = Serial RS485

F = with flow measurementN = without flow measurement

N = No Built-in Pump

5 = 0.5µm Minimum sensitivity

0 = 0.1 cfm 1 = 1.0 cfm

208871 5 - NF - ED - 0 (Example) 208871 5 - NF - SA - B (Example)

Page 19: MET ONE 7000 Series Remote Airborne Particle Counters Customer Name Date Presenter Presenter Title

Copyright 2008 Hach Ultra Analytics – Page 19

Standard Shipment Includes

Item Number

Description

1 MET ONE 7000 Counter

2 Mounting Plate

3, 4 Isokinetic Probe (0.1 or 1.0 cfm)

5 Wall Plate

6 Communication Cable with Sealed RJ-45 Connectors

7 Power Cable AC or DC

8 Vacuum Tubing with Sealed Quick Connectors

Page 20: MET ONE 7000 Series Remote Airborne Particle Counters Customer Name Date Presenter Presenter Title

Copyright 2008 Hach Ultra Analytics – Page 20

MET ONE 7000 Series