Page 1: MEMBRANE PARTICLE FILTERS · • DOC - large pore foam structure: insensitve for plugging - sulfur tolerant coating –and/or FBC - converts OC drying soot; agglomerating particles,

© 2018, VERT

MEMBRANE PARTICLE FILTERSwith PULSE CLEANING

for MARINE and OTHERAPPLICATIONS

10. VERT-Forum – March 14th 2019

Thomas Lutz / Andreas Mayer

Page 2: MEMBRANE PARTICLE FILTERS · • DOC - large pore foam structure: insensitve for plugging - sulfur tolerant coating –and/or FBC - converts OC drying soot; agglomerating particles,

BACKGROUND and TARGET

• Marine contribution to global PM-burden

• Marine diesel fuel properties → sulfur and ash

• PM characteristics

• Why not standard wall flow DPF?

→ MAN experience (Lauer, 16th ETH-NPC)

• Membrane filter structure

• → A membrane filter based concept

2

Page 3: MEMBRANE PARTICLE FILTERS · • DOC - large pore foam structure: insensitve for plugging - sulfur tolerant coating –and/or FBC - converts OC drying soot; agglomerating particles,

Three Major Sources of PM and PNMTZ 2011 – one large ship equals 80’000 trucks

3

Page 4: MEMBRANE PARTICLE FILTERS · • DOC - large pore foam structure: insensitve for plugging - sulfur tolerant coating –and/or FBC - converts OC drying soot; agglomerating particles,

EMISSION LIMITS

4

Page 5: MEMBRANE PARTICLE FILTERS · • DOC - large pore foam structure: insensitve for plugging - sulfur tolerant coating –and/or FBC - converts OC drying soot; agglomerating particles,

ON-BOARD PM EXPOSITION‘AIDA Prima’, launched 2014

E.g. ice rink behind the stack:

Measured values:

½-h-average: 68’000 #/cc

peak values: > 250’000 #/cc

Source: J. Kersten, plusminus/ARD, March 2017

5

Page 6: MEMBRANE PARTICLE FILTERS · • DOC - large pore foam structure: insensitve for plugging - sulfur tolerant coating –and/or FBC - converts OC drying soot; agglomerating particles,

TYPICAL PARTICLE SIZE DISTRIBUTIONSULZER 4 RT-flex 58T-B - MDO

Source: KTI Project 4207.2 KTS

6

Page 7: MEMBRANE PARTICLE FILTERS · • DOC - large pore foam structure: insensitve for plugging - sulfur tolerant coating –and/or FBC - converts OC drying soot; agglomerating particles,

PARTICLE COMPOSITION

Source: KTI Project 4207.2 KTS

7

Page 8: MEMBRANE PARTICLE FILTERS · • DOC - large pore foam structure: insensitve for plugging - sulfur tolerant coating –and/or FBC - converts OC drying soot; agglomerating particles,

DPF BACKPRESSURE DEVELOPMENTIrreversible due to high ash content

Backpressure [mbar]Temperature at filter inlet

Source: P. Lauer – 16th ETH-NPC 2012 8

Page 9: MEMBRANE PARTICLE FILTERS · • DOC - large pore foam structure: insensitve for plugging - sulfur tolerant coating –and/or FBC - converts OC drying soot; agglomerating particles,

CRUCIAL REQUIREMENTS for MARINE DPF

Sulfur tolerant > 20’000 ppm

Ash tolerant > 20 times more ash than HDV

Regeneration below 250°C (2-stroke engines)

OC/EC > 4 sticky particles

DOC sulfur tolerant and not plugging

Low backpressure ( < 100 mbar)

Continuous soot + on site ash cleaning

Ceramic membrane filter with pulse cleaning

9

Page 10: MEMBRANE PARTICLE FILTERS · • DOC - large pore foam structure: insensitve for plugging - sulfur tolerant coating –and/or FBC - converts OC drying soot; agglomerating particles,

DRY DUST COLLECTOR for HIGH-TEMPERATURE GASESNGK CERALLEC System

10

Source: NGK 2016

Page 11: MEMBRANE PARTICLE FILTERS · • DOC - large pore foam structure: insensitve for plugging - sulfur tolerant coating –and/or FBC - converts OC drying soot; agglomerating particles,

Source: NGK 2016

NGK MEMBRANE FILTER

11

Page 12: MEMBRANE PARTICLE FILTERS · • DOC - large pore foam structure: insensitve for plugging - sulfur tolerant coating –and/or FBC - converts OC drying soot; agglomerating particles,

A NEW CONCEPT for a MARINE DPF SYSTEM

• DOC- large pore foam structure: insensitve for plugging

- sulfur tolerant coating – and/or FBC

- converts OC drying soot; agglomerating particles, heating gas

• DPF- very fine pore membrane structure

- high space velocity permitted small bulk size

- high frequency on site pulse cleaning to keep backpressure small

- pressure pulse formation and wave propagation will be crucial

- modular design

• SCR- high cell density due to clean gas

12

Page 13: MEMBRANE PARTICLE FILTERS · • DOC - large pore foam structure: insensitve for plugging - sulfur tolerant coating –and/or FBC - converts OC drying soot; agglomerating particles,

FILTER SYSTEMTEST RIG

(sketch)

1 Pressure wave generator

2 Membrane filter

3 Foam DOC

Compressed air vessel

Valve (e.g. sleeve valve)

Fast pressure sensors

Measurement of soot load(balance)

Fast pressure sensors

T, mass flow, PN (ev.size distrib. etc.)exhaust emissions

150x150x500 mm

T, PN, ev. size distr.

p, T

massflow

Exhaust emissions, PN etc.

NGK Cerallecelement

Fo

am

DO

C

V = 1.0 - 1.2 dmDOC

3DOC:

(150 x 150 mm or O 150 mm)

13

2

1

3

Page 14: MEMBRANE PARTICLE FILTERS · • DOC - large pore foam structure: insensitve for plugging - sulfur tolerant coating –and/or FBC - converts OC drying soot; agglomerating particles,

SHOCK WAVE GENERATION

Sleeve valvemovement

Opening time: 0.2 ms

Source: BBC Comprex research

14

Wave front

Page 15: MEMBRANE PARTICLE FILTERS · • DOC - large pore foam structure: insensitve for plugging - sulfur tolerant coating –and/or FBC - converts OC drying soot; agglomerating particles,

WORK PACKAGESTwo years from January 2019

15

Page 16: MEMBRANE PARTICLE FILTERS · • DOC - large pore foam structure: insensitve for plugging - sulfur tolerant coating –and/or FBC - converts OC drying soot; agglomerating particles,

PARTNERS

• Research Partners

- AFHB

- Combustion and flow solutions GmbH

• Industrial Partners

- NGK - UMICORE

- LIEBHERR - Fraunhofer Institut

- WIN G&D

- Pure Clean Air

• Financing Partners

- BAFU-Technologiefonds (CHF 170‘000)

- VERT (CHF 45‘000)

• Project Management: A. Mayer, Th. Lutz

16

Page 17: MEMBRANE PARTICLE FILTERS · • DOC - large pore foam structure: insensitve for plugging - sulfur tolerant coating –and/or FBC - converts OC drying soot; agglomerating particles,

A Final Remark

The ability of on site ash removing from the DPF might also be an attractive solution for construction machinery and locomotives

17

Page 18: MEMBRANE PARTICLE FILTERS · • DOC - large pore foam structure: insensitve for plugging - sulfur tolerant coating –and/or FBC - converts OC drying soot; agglomerating particles,

Towards a blue sky and blue water

18

Thank you for your attention