  • PLAN DE MEJORAMIENTO DEL SISTEMA DE TRATAMIENTO DE

    AGUAS RESIDUALES DE LABORATORIOS COASPHARMA,

    BOGOT D.C.

    SYSTEM IMPROVEMENT PLAN OF WASTEWATER TREATMENT

    LABORATORY COASPHARMA, BOGOTA D.C.

    Mara Fernanda Pabn Vidarte1

    Erika Johanna Sarria Rumie2

    lvaro Chvez Porras3

    1 Microbiloga, Universidad de Los Andes, Bogot, D.C., Colombia

    juanasamuel2211@gmail.com

    2 Bacteriloga/Microbiloga con nfasis en el Sector Industrial, Universidad Libre, Bogot D.C., Colombia,

    erikasarria@gmail.com

    3 Ingeniero Industrial, PhD, Docente del Programa de Ingeniera Industrial, Universidad Militar Nueva Granada,

    Bogot, D.C., Colombia

    alvaro.chavez@unimiltar.edu.co

    Resumen: En la actualidad, Laboratorios COASPHARMA SAS, se encuentra en proceso de

    certificacin, con el fin de garantizar los procesos de produccin, cumplir los parmetros de calidad y

    adoptar el mejoramiento continuo para ofrecer los mejores productos en el mercado. Dentro de sus

    procesos de aseguramiento, se encontr la necesidad de mejorar la calidad del agua residual que se

    vierte al alcantarillado, puesto que no estaba siendo tratada en forma adecuada, y los valores generados

    para DBO y DQO, no se encontraban dentro de los parmetros permitidos por la Resolucin 3957 de

    2009. COASPHARMA posee dos plantas de tratamiento de aguas residuales, una en la zona de

    Ricaurte (PTAR-Ricaurte), y la otra en la zona Paloquemao (PTAR-Paloquemao). Con el objeto de

    buscar el mejoramiento continuo en los procesos de la Cooperativa, en el ao 2011 se evalu el

    impacto negativo que generaban las aguas residuales provenientes de la fabricacin de productos

    farmacuticos, veterinarios y cosmticos de cada planta, y del casino ubicado en Paloquemao que

    tiene unos 400 usuarios. En los estudios preliminares que se hicieron durante los aos 2009 a 2011, se estableci que el

    incumplimiento de los parmetros mencionados, se deba a altos picos de produccin que

    coincidan con los meses de fin de ao en cada planta, cuando hay mayor actividad productiva. Al

    mismo tiempo, se observ que la fabricacin de ciertos productos especficos tambin generaba

    dichos picos. Como las caractersticas de las aguas residuales pueden diferir mucho entre la misma

    industria y dependiendo del tipo de producto fabricado, existe una gran variedad de residuos, fue

    necesario implementar diferentes sistemas de tratamiento, puesto que el contenido de sustancias

    orgnicas e inorgnicas presentes tienden a mezclarse de tal manera que los procesos u

    operaciones convencionales utilizados no eran efectivos. Se busc entonces, combinar sistemas

    para asegurar el cumplimiento de los parmetros exigidos por la normatividad del Distrito Capital,

    puesto que una de las fallas que se encontr en los resultados de DBO y DQO, fueron valores

    fuera de especificacin sobre los 800 mg/L y 1.500 mg/L respectivamente, acompaados de altos

    niveles de slidos en suspensin, grasas, aceites y detergentes, con valores sobre los 10 mg/L,

    resultados nada alentadores frente a la visita realizada por la Secretara Distrital de Ambiente, que

    solicit dar solucin inmediata a este incumplimiento, y responsabiliz a las PTAR de la

    Cooperativa, del proceso de depuracin de las aguas antes de ser vertidas en el alcantarillado. En

    esta forma, hubo necesidad de replantear los procesos internos y surgi el Plan de mejoramiento

    para el tratamiento de aguas residuales con control en el efluente, participando en los programas de

    produccin ms limpia para mitigar el impacto ambiental sobre la cuenca del ro Fucha.

  • Palabras clave: Aguas residuales, Demanda Bioqumica de Oxgeno (DBO5), Demanda Qumica

    de Oxgeno (DQO), Resolucin 3957 de 2009, Plan de mejoramiento

    Abstract: Currently, SAS COASPHARMA Laboratories, is in the process of certification,

    in order to ensure production processes, quality parameters meet and adopt continuous

    improvement to offer the best products on the market. Within its assurance processes, we

    found the need to improve the quality of wastewater that is discharged into the sewer, since

    he was not being treated properly, and the generated values for BOD and COD, were not

    within the parameters permitted by Resolution 3957 of 2009. COASPHARMA has two

    treatment plants wastewater, an area Ricaurte (Ricaurte-WWTP), while the other area

    Paloquemao (WWTP-Paloquemao). In order to seek continuous improvement in the

    processes of the Cooperative, in 2011 evaluated the negative impact that wastewater

    generated from the manufacture of pharmaceutical, veterinary and cosmetic of each plant

    and casino located in Paloquemao that has about 400 people as users.

    In preliminary studies made during the years 2009 to 2011, it was established that the

    breach of the above parameters was due to high production peaks coinciding with the

    months of year-end on each floor, where there is more productive activity. At the same

    time, it was observed that the manufacture of specific products such peaks also generated.

    Since the characteristics of the wastewater can vary greatly from the same industry

    depending on the type of product being manufactured, there is a great variety of waste, it

    was necessary to implement different treatment systems, since the content of organic and

    inorganic substances present tend to mingle so that conventional process or operations used

    were not effective. It then sought to combine systems to ensure compliance with the

    parameters required by the regulation of the Capital District, since one of the faults found in

    the results of BOD and COD, were out of specification values above 800 mg/L and 1.500

    mg/L respectively, accompanied by high levels of suspended solids, fats, oils and

    detergents, with values above 10 mg/L, all encouraging results against the visit by the

    District Department of the Environment, who requested to give immediate solution this

    failure, and blamed the WWTP of the Cooperative, the process of water purification before

    being discharged into the sewer. In this way, there need to rethink internal processes and

    emerged Improvement Plan for wastewater treatment in the effluent control, participating in

    cleaner production programs to mitigate the environmental impact on the river Basin

    Fucha.

    Keywords: Wastewater biochemical oxygen demand (BOD5), Chemical Oxygen Demand

    (COD), Resolution 3957 of 2009, Improvement Plan.

    1 INTRODUCCIN

    Laboratorios COASPHARMA SAS, es la fusin de dos cooperativas colombianas: Planta de fabricacin

    de productos Farmacuticos y Veterinarios (FARMACOOP), y Planta de fabricacin de productos

    Cosmticos y Farmacuticos (COSMEPOP), ubicadas en dos sectores diferentes de la ciudad de Bogot.

    En 1974, naci la Cooperativa de trabajo asociado de produccin, comercializacin y servicios

    farmacuticos (FARMACOOP), primera cooperativa de trabajo asociado cuyo objeto social es la

    produccin, comercializacin y distribucin de productos farmacuticos para consumo humano y

    veterinario. En 1996, se cre la Empresa Cooperativa Multiactiva de Empleados de Cosmticos y

    Populares (COSMEPOP), encargada de fabricar y distribuir productos cosmticos.

    En la actualidad, Laboratorios COASPHARMA SAS se encuentra en proceso de certificacin, teniendo en

    cuenta que FARMACOOP haba obtenido esta certificacin en 2010, para la Norma Tcnica Colombiana -

    NTC ISO 9001: 2008. Se espera que para el ao 2012, en esta certificacin se incluya a COSMEPOP, puesto

    que antes de la fusin, las dos Cooperativas venan funcionando en forma independiente, y contaban con el

    certificado de Buenas Prcticas de Manufactura (BPM), otorgado por el Instituto Nacional de Vigilancia

    de Medicamentos y Alimentos (INVIMA). Esta certificacin seguir garantizando los procesos de

    produccin, cumpliendo los parmetros de calidad y buscando el mejoramiento continuo para ofrecer lo

    mejor en el mercado. Para seguir incentivando la conciencia ambiental dentro de sus procesos de

    aseguramiento, la Cooperativa desea mejorar la calidad del agua residual que vierte al alcantarillado, porque

    sus residuos no se tratan adecuadamente y pueden causar un impacto negativo en los ecosistemas del ro

    Fucha y afectar la salud de la comunidad en general [1].

  • En este documento, las dos plantas fueron identificadas como PTAR- Ricaurte (COSMEPOP), y

    PTAR-Paloquemao (FARMACOOP), y cuentan con un moderno sistema de produccin con maquinaria

    de avanzada tecnologa. En busca del mejoramiento continuo, se evalu el impacto negativo que generan

    las aguas residuales que provienen de la fabricacin de productos farmacuticos, veterinarios y

    cosmticos de ambas plantas, y el rea administrativa del casino que tiene unos 400 usuarios diarios. Al

    adelantar los estudios preliminares sobre el tema, se encontr que durante los aos 2009 a 2011, el

    incumplimiento de dichos parmetros obedeci principalmente a picos altos de produccin en los meses

    de fin de ao, y a la fabricacin de productos especficos en cada planta. Las aguas residuales en el caso

    de la PTAR- Ricaurte, se caracterizaron por la presencia de una alta carga orgnica que se traduce en una

    elevada Demanda Biolgica de Oxgeno (DBO5), que mide la cantidad de materia susceptible de ser

    consumida u oxidada por medios biolgicos [2] con valores fuera de especificacin sobre los 800 mg/L;

    valores de la Demanda qumica de O