Meeting Various Needs with
the FUJITSU GENERAL VRF AIRSTAGE Series
INDOOR UNITS
Compact Cassette
HighStatic Pressure Duct
Cassette
Floor / Ceiling
Compact Duct
Ceiling
Slim Duct(Drain Pump internal)
Compact Wall Mounted(EEV internal / EEV external)
Low Static Pressure Duct /Duct
Wall Mounted
02
The AIRSTAGE J-II Series adopts the best technology and was designed with the greatest care to provide not only energy savings and comfort but also ease of design, installation, and maintenance. Fujitsu General provides air conditioning systems for a wide range of applications from small office buildings and stores to large houses.
Building owners End usersInstallers Service and Management companies
Various Line-up for each buildings
OUTDOOR UNITS
4HP5HP6HP
AJ*A36LALH
AJ*A45LALH
AJ*A54LALH
AJ* : AJY (FUJITSU), AJH (GENERAL)
Wide lineup of indoor units and controllers to support a variety of properties.
CONTROLLERS
CentralRemote Controller
GroupRemote Controller
Touch PanelController
System Controller (Software)
WiredRemote Controller
SimpleRemote Controller
WirelessRemote Controller
03
Large Homes
Central Controller Individual Controller
Small Office
The building load is the range of almost 40 % to 80%. Therefore, most air conditioners do not operate at maximum load, but operate at low to medium loads. Especially, for multi system, operation performance at partial load is important because all the air conditioners do not always operate all the time. Aiming at energy saving performance matched to actual operation, Fujitsu General has developed a high intermediate performance air conditioner corresponding not only to the rated performance at 100% load, but also to low to medium load
04
High EER / COP
High part load performance (6HP class)
FEATURES
Efficiency in actual operation
Load curve (a typical office building)
4 HP 5 HP
Conditions : Connected indoor units: AUXA30LALH+AUXD24LALHCooling : indoor temp. of 27°CDB / 19°CWB, outdoor temp. of 35°CDB / 24°CWBHeating : indoor temp. of 20°CDB / 15°CWB, outdoor temp. of 7°CDB / 6°CWB
6 HP
4.534.00 4.20
3.603.95
3.45
5.75
COPHeating part load
EERCooling part load
5.73
100%3.95
50%
100%3.45
50%
: COP: EER
66 %UP
46 %UP
00
20
40
60
80
100
3 6 9 12Time (h)
15 18 21 24
Bui
ldin
g lo
ad (%
)
05
Com
pres
sor
effic
ienc
y
High
HighCompressor capacity
DC Twin Rotary compressor
Highly accurate parts
Optimized refrigerant flow design
High efficiency compressor motorDC twin rotary compressorEfficiency in all load regions is good. Especially good performance from low to medium at normal operation.
Large propeller fanHigh performance and low noise realized by large propeller and optimization of angle.
DC inverter controlEfficiency is improved by mounting of new active filter module.
Subcool heat exchangerCooling performance is improved by mounting of dual tube heat exchanger.
DC fan motorMiniaturized, low noise, high efficiency, multi-stage DC fan motor is mounted.
Large heat exchangerHeat exchange performance is substantially improved by mounting of 3-row large heat exchanger.
Pre
ssur
e
Enthalpy
effect
Cooling performance improved
Auto Off functionThis prevents waste of energy.
Heating Cooling
OriginalSet Temp.
Set point limitation setting
Central Remote Controller
30
28
26
24
22
20
18
16
14
12
10
Cooling Set Temperature
Economy operationControl Temperature
Heating Set Temperature
Economy operationControl Temperature
Set Temp.
MAX. -4°C
MAX. +2°C
Economy operation
UpUp
Economy operation
Set Temp.
DownDown
DownDown
Capacity
Time
Settinglevel
18:00 20:00 22:00
OFF OFF OFF
Wasteful Operation is Prevented.
Operation Performance is Efficiently Controlled.Room temperature set point limitationThe minimum and maximum temperature range can be set.
Economy operationThe temperature setting is offset automatically over a certain period of time.
Capacity save operation The power consumption at peak is cut down.
Capacity saveSettingrange
80%
60%
40%
0%
06
FEATURES
(°C)
Current model
Function setting is required. 1 indoor unit (Master) can apply this function.
ON
OFF
Operation stopped at oil recovery Time
Time
ONJ-II seriesSet Temp.
Temp.(°C)
Noiselevel
Time
(4~6HP)
Low Noise Design
Various Comfort Control Function
Heating capacity is improved at low outdoor temperature by our advanced technology.
Low noise design of outdoor unitSignificantly reduced noise by optimized airflow structure design of outdoor unit.
Powerful Heating
Low noise modeOutdoor unit can be switched to silent mode, depending on the installation environment.
Easy auto changeover functionAt the auto mode, cooling and heating mode is switched automatically to maintain the setting temperature.
Non-stop oil recovery operationThe product continues to operate without stopping the cooling or heating operation during oil recovery modes.
Auto louver grill (Option for Slim Duct)
Auto louver grille provides comfort and efficient heating with louver controlled ductable outlet
Rated noise value
-5dB ~ -6dB
56dB
53dB
Current model
J-II series
6HP class (Cooling)
Low noise mode
Heating operation
Heating operation
07
33%UP !
Cooling operation
7
Current model (6HP class)
16.6
Hea
ting
cap
acity
(kW
)
J-II series (6HP)
Outdoor temperature (°C)
Current model (6HP class)
-20 -10 0
With Auto Louver40
30
15
20
25
35
Tem
pera
ture
(°C
)
FEATURES
Central Control of Small Office, Shop, etc.
08
Control system composition example
BACnet® Gateway(Software)
Network Convertorfor LONWORKS®
System Controller(Software)
Building controlcomputer
System Controller (Software)UTY-APGXMax. controllable 1,600 indoor units
Convertor forBMS Control
Building ManagementSystem
BACnet® Gateway(Software)UTY-ABGX
Network Convertorfor LONWORKS®
UTY-VLGX
NetworkConvertorUTY-VGGX
Security system
Ventilation system
Lighting facilities
A/C central controller
Group Remote ControllerUTY-CGG*Max. controllable18 indoor units
Central Remote ControllerUTY-DCG*Max. controllable100 indoor units
Touch Panel ControllerUTY-DTG*Max. controllable400 indoor units
G*: GY (FUJITSU), GG (GENERAL)
VRF network system
or
CentralRemote Controller
Touch Panel Controller
NetworkConvertor
Group Remote Controller
Group Remote ControllerUTY-CGG*
• Max. controllable 18 indoor units
Individual and Central Control of Large Homes
09
Control system composition example
CentralRemote Controller
or
GroupRemote Controller
WirelessRemote Controller
WiredRemote Controller
+Wireless
Remote Controller
IR Receiver Unit+
Wireless Remote Controller
SimpleRemote Controller
WiredRemote Controller
+Simple
Remote Controller
WiredRemote Controller
Central Remote ControllerUTY-DCG*
or
• Automatic display of number of connected indoor unit
• Max. controllable 100 units
Simple Remote Controller
Wired Remote ControllerUTY-RNK*
With operation modeUTY-RSK*
Without operation modeUTY-RHK* K*: KY (FUJITSU), KYT (FUJITSU), KG (GENERAL)
H*: HY (FUJITSU), HG (GENERAL) G*: GY (FUJITSU), GG (GENERAL)
Wireless Remote ControllerUTY-LNH*
Long Piping Length
High Capacity Connection
Our advanced refrigerant control technology allows us to achieve a total refrigerant piping length of 180 m. This opens up new possibilities in system design.
180 m max.
Height difference between indoor and indoor units
15 m max.
Piping length from first separation tube to the farthest indoor unit
40 m max.
Height difference between outdoor and indoor units
30 m max.
Actual piping length
120 m max.
Total piping length
CoolingCooling46°C
21°C
-5°C -5°C
-20°C -20°C
Heating
(°C)
-20°C areaOperation possiblein heating.
50
40
30
20
10
0
-10
-20
Number of connectable indoor unit
4 HP
5HP
6 HP
2 to 6 units
2 to 8 units
2 to 9 units
Wide operating rangeInstallation in extreme temperature conditions is possible due to an increase in operational range.Cooling : -5°C~46°CHeating : -20°C~21°C
10
FEATURES
12 types, 52 models
Indoor unit Connectable indoor unit capacity range
130 % max.
3 7 1 0 2 4 5 6
Easier InstallationEasy piping connectionImprovement of the reliability by decreasing the flare connection.
Easy to connect with V-II communication system
It is possible to connect directly with the transmission cable of the V-II system without convertor.
J-II system V-II system
Connects without a converter
Easy wiring connection• Decreasing wiring mistakes by using non-polar 2 wires.(Remote controller cable is 3 wires)
• Improvement of wiring installation by common with V-II power supply method.
Flexible installation of outdoor unitCorresponds to the outdoor unit concentration installation.
Convenient Commissioning SupportAutomatic address setting functionThe address of each indoor unit can be automatically set by button switch of outdoor unit.
Connection check functionPossible to confirm whether wiring connection and address setting are correct by check run function for a short time.
Reduced installation intervals by front access
Flexible installation by 4 way pipe direction
11
Press the push buttonof outdoor unit.
• Display connected indoor unit numbers• Duplicately set address number of
indoor unit can be displayed
Flare connection
Terminal box
Flare connection
EV kit
J-II series Previous model
Power supply cablePower supply(Indoor )
Power supply(Outdoor )
Emergencystop function
Emergency Stop Function
FEATURES
SU MO TU WE TH FR SA
Wired Remote Controller
Simple Remote Controller
Error status can be checked easily via the indoor unit wired controller An error code is displayed on a liquid crystal screen.
Faulty unit number (Remote controller address)Error code
Remote controller address
Error code
Design for Easy MaintenanceEasy to read 7-segment LEDConfirm detail operational and trouble status without using specific equipment
Movable PCB panelEasier for maintenance work behind the PCB
7-segment LED
Emergency alarm can be received by indoor, outdoor units, Central Remote Controller or Touch Panel Controller when they received it, all units will be stopped.
Touch Panel Controller
CentralRemote Controller
or
Emergencystop function
Emergencystop function
T h P l
Central
Note : In case of received Emergency alarm by Indoor / outdoor unit : All units connected within same refrigerant system will be stopped. Central Remote Controller or Touch Panel Controller : all units connected within VRF network system with Central Remote Controller or Touch Panel Controller will be stopped.
12
Equipment Detail (Diagram)
Trouble diagnosis by Service ToolConnection to Service Tool• Detail operation status and recent
error history can be checked and analyzed by using Service Tool.
• Last 5 min. operation memory can be also recorded.
Transmission cable(Non-polar 2 wires)
Service ToolUTY-ASGXUSB adaptor(Field supplied)
Software
OUTDOOR UNITS
Specifications
Dimensions
AJ* : AJY (FUJITSU), AJH (GENERAL)
AJ* : AJY (FUJITSU), AJH (GENERAL)
AJ*A36LALH / AJ*A45LALH / AJ*A54LALH
Detail
650
970 32 12370
Terminal blocks (Transmission)
Terminal blocks (Power)
3-Way valve (Liquid)
3-Way valve (Gas)
Ø28
(Cab
le po
rt)
Ø28 (Cable port)
Pipe portPipe port
Pipe & cable port
Pipe port89
50438
622
65 15
1450
21 55 21 65
166
370
43(L
iquid)
51(G
as)
(410
)40
3213
34
907
297
(Gas
valve
)
279
5095 12
050 50
25
87131
(Liqu
id va
lve)
()
1000
111
70
155
14221
227
305
341
154
36
Ø28 (Cable port)Ø28 (Cable port)
Ø28 (Cable port)Ø28 (Cable port)
AA
(Unit : mm)
13
Capacity range HP
Model name
4 5 6
AJ*A36LALH AJ*A45LALH AJ*A54LALH
Power source
Capacity kW
kW
W / W
dB(A)
mm
Cooling
Cooling
Heating
Dimensions (H×W×D)
Heat exchanger fin
COP
EER
Input power
Sound pressure level
Connection pipe diameter
Weight
mm
kg
kg
11.2
12.5
14.0
16.0
1,334 x 970 x 370
Blue fin
117
Maximum connectable indoor unit 6 8 9
15.5
18.0
Heating 2.76 3.81 4.56
2.80 3.89 4.49
Cooling
Heating
Cooling
Heating
Air flow rate High m3/h
4.53 4.20 3.95
4.00 3.60 3.45
6,200 6,400 6,900
50 51 53
52 53 55
Refrigerant charge 4.8 5.3
9.52
15.88 19.05
Liquid
Gas
°CDBOperation rangeCooling
Heating
-5 to 46
-20 to 21
Note : Specifications are based on the following conditions.Cooling : Indoor temperature of 27°CDB / 19°CWB, and outdoor temperature of 35°CDB / 24°CWB.Heating : Indoor temperature of 20°CDB / (15°CWB), and outdoor temperature of 7°CDB / 6°CWB.Pipe length : 7.5 m; Height difference between outdoor unit and indoor unit : 0 m.The protective function might work when using it outside the operation range.
1Ø, ~ 230 V, 50 Hz
INDOOR UNIT
14
* : Y(FUJITSU), H(GENERAL)
Compact Cassette
Cassette
Compact Duct
Slim Duct(Drain pump internal)
Low Static Pressure Duct
High Static Pressure Duct
Floor / Ceiling
Ceiling
Wall Mounted
Duct
Compact Wall Mounted(EEV internal)
Compact Wall Mounted(EEV external)
AUXB07LALH
ARXB07LALH
AS*E07LACH
AS*A07LACH
ARXD07LATH
AUXB09LALH
ARXB09LALH
AS*E09LACH
AS*A09LACH
ARXD09LATH
AUXB12LALH
ARXB12LALH
AS*E12LACH
AS*A12LACH
ARXD12LATH
AUXB14LALH
AS*E14LACH
ARXB14LALH
AS*A14LACH
ARXD14LATH
AB*A12LBTH AB*A14LBTH
12 Types, 52 Models, Capacity range from 2.2kW to 14.0kW
With this model, connection of EV kit is necessary
Indoor Unit Lineup
Capacity range (kW)
Model code
2.27
2.89
3.612
4.514
15
Comprehensive range of indoor units of variety design and capacity ranges available which can be selected to suit any air conditioning needs.
AUXA54LALHAUXA36LALH
ARXB36LATH
ARXC36LATH
ARXA36LATH
AUXA45LALH
ARXC45LATH
ARXB45LATH
ARXA45LATH
AUXA30LALH
AB*A54LBTHAB*A36LBTH AB*A45LBTHAB*A30LBTH
ARXB30LATH
ARXA30LATH
AUXB18LALH
ARXB18LALH
AUXD18LALH
ARXD18LATH
AUXD24LALH
ARXB24LATH
ARXA24LATH
AS*A24LACHAS*A18LACH AS*A30LACH
AUXB24LALH
ARXD24LATH
AB*A18LBTH AB*A24LBTH
7.124
5.618
11.236
9.030
12.545
14.054
Compact Cassette
Note : Specifications are based on the following conditions. Cooling : Indoor temperature of 27°CDB / 19°CWB, and outdoor temperature of 35°CDB / 24°CWB.Heating : Indoor temperature of 20°CDB / (15°CWB), and outdoor temperature of 7°CDB / 6°CWB.Pipe length : 7.5 m; Height difference between outdoor unit and indoor unit : 0 m.
INDOOR UNIT
Fast
Slow
Wind velocity
16
Air Outlet Shutter Plate:Fresh Air Intake Kit:Insulation Kit For High Humidity:
UTR-YDZBUTZ-VXAAUTZ-KXGC
SpecificationsModel No.
Power source
Air flow rate
Input power
Capacity
Sound pressure level
Dimensions (H x W x D)
Weight
Connection pipe diameter
Grille(option)
mm
kg
mm
kg
mm
V/ø/Hz
m3/h
W
kW
dB(A)
AUXB24LALH
7.1
8.0
84
1,030
830
450
50
44
30
AUXB18LALH
5.6
6.3
36
710
580
400
41
35
27
AUXB14LALH
4.5
5.0
35
680
590
390
38
34
27
AUXB12LALH
3.6
4.1
29
600
530
390
37
34
27
AUXB09LALH
2.8
3.2
25
550
450
350
35
30
25
AUXB07LALH
2.2
2.8
25
540
450
350
34
30
25
Model name
Dimensions (H x W x D)
Weight
High
High
Med
Cooling
Heating
Low
Med
Low
Liquid (Flare)
Gas (Frare)
Drain
AUXB07LALHAUXB09LALHAUXB12LALH
AUXB14LALHAUXB18LALHAUXB24LALH
Powerful wide air flow & Quiet operation
Grille is an option
1Ø, 230V ~, 50Hz
245 x 570 x 570
ø25 (I.D) ; ø32 (O.D.)
UTG-UFYC-W (FUJITSU brand); UTG-UFGC-W (GENERAL brand)
50 x 700 x 700
2.6
15
ø6.35
ø12.70
17
ø9.52
ø15.88
Optional parts
High efficiency 2-stage turbo fan
Adoption of laminar wing
Spin direction Airflow direction
Quiet
Airflow runs through smoothly along the laminar wing
No airflow separation
Laminar wingQuiet
Quiet quality
Designed by CFD-analysis (fluid) simulations
Optimization of wing form (laminar wing type) and wing number (7 blades each)
High lift drain pump
Ceiling panelHeight
700mm
Previous turbo fan2-stage turbo fan1-stage
+2-stage2 stage
In the case of a conventional fan, the air outlet range was narrow as the airflow moved to the motor side which meant the velocity of air passing through the heat exchanger was uneven.
Heat exchangeefficiency:
20%UP
A evenly spread air distribution across the heat exchanger is possible due to the new 2 stage turbo fan which produces two separate airflow streams.
Cassette
IR Receiver Kit :Air Outlet Shutter Plate :Panel Spacer :Insulation Kit for High Humidity :Wide Panel :Fresh Air Intake Kit :H* : HY(FUJITSU), HG(GENERAL)
UTY-LRH*B1UTR-YDZCUTG-BGYA-WUTZ-KXGA / UTZ-KXGBUTG-AGYA-WUTZ-VXGA
High efficiency turbo fan with 3-dimensional blade
450mm
Heat exchanger< Motor side >
Uneven airflow
Separation phenomenon of airflow causes noise
: Spin direction : Airflow direction : Turbulent flow noise
< Motor side >Heat exchanger
3-dimensional blade
High efficiency airflow distribution has been achieved by the introduction of a 3 dimensional blade which increases the air passing over the heat exchanger.
Previous blade
500mm
No airflow separation
Quiet
Previous turbo fanAir passing through the heat exchanger was uneven and the air would only flow close to the ceiling.
Fast
Slow
Wind velocity
Improvement of the airflow distribution
The louvre design distributes air leaving a space between the chassis and the ceiling allowing far and wide air flow distribution.
Much less temperature irregularity happens by spreading airflow widely
Note : Specifications are based on the following conditions. Cooling : Indoor temperature of 27°CDB / 19°CWB, and outdoor temperature of 35°CDB / 24°CWB.Heating : Indoor temperature of 20°CDB / (15°CWB), and outdoor temperature of 7°CDB / 6°CWB.Pipe length : 7.5 m; Height difference between outdoor unit and indoor unit : 0 m.
Bottom viewFront part Ceiling
Rear part
Round louvre
17
Grille is an option
Powerful, wide airflow and quiet operation
AUXD18LALHAUXD24LALHAUXA30LALH
AUXA36LALHAUXA45LALHAUXA54LALH
SpecificationsModel No.
Power source
Air flow rate
Input power
Capacity
Sound pressure level
Dimensions (H x W x D)
Weight
Connection pipe diameter
Grille(option)
mm
kg
mm
kg
mm
V/ø/Hz
m3/h
W
kW
dB(A)
14.0
16.0
119
2,000
1,370
1,100
47
39
33
12.5
14.0
99
1,900
1,370
1,100
46
39
33
ø19.05
11.2
12.5
80
1,800
1,300
1,100
44
38
33
9.0
10.0
59
1,600
1,300
1,100
40
38
33
7.1
8.0
46
1,280
1,040
870
38
33
29
ø15.88
5.6
6.3
39
1,150
940
870
36
30
29
Model name
Dimensions (H x W x D)
Weight
High
High
Med
Cooling
Heating
Low
Med
Low
Liquid (Flare)
Gas (Frare)
Drain
1Ø, 230V ~, 50Hz
ø9.52
ø25 (I.D.) ; ø32 (O.D.)
UTG-UGYA-W (FUJITSU brand); UTG-UGGA-W (GENERAL brand)
50 x 950 x 950
5.5
246 x 840 x 840
23
288 x 840 x 840
27
Optional parts
AUXA54LALHAUXA45LALHAUXA30LALHAUXD24LALHAUXD18LALH AUXA36LALH
INDOOR UNIT
Remote Sensor Unit :IR Receiver Unit :Drain Pump Unit :*WC : YWC, TWC
UTD-RS100UTB-*WCUTZ-PX1BBA
Optional parts
Note : Specifications are based on the following conditions.Cooling : Indoor temperature of 27°CDB / 19°CWB, and outdoor temperature of 35°CDB / 24°CWB.Heating : Indoor temperature of 20°CDB / (15°CWB), and outdoor temperature of 7°CDB / 6°CWB.Pipe length : 7.5 m; Height difference between outdoor unit and indoor unit : 0 m.
SpecificationsModel No.
Power source
Air flow rate
Input power
Capacity
Sound pressure level
Dimensions (H x W x D)
Weight
Static pressure range
Standard static pressure
Connection pipe diameter
mm
kg
mm
V/ø/Hz
m3/h
W
kW
dB(A)
Pa
5.6
6.3
96
890
810
730
0 to 50
25
36
34
30
ø9.52
ø15.88
4.5
5.0
90
800
750
700
0 to 50
25
33
32
30
217 x 953 x 595
25
2.8
3.2
55
440
370
340
0 to 50
25
31
29
27
217 x 663 x 595
18
ø6.35
ø12.70
2.2
2.8
46
370
310
280
0 to 50
25
29
26
24
High
High
Med
Cooling
Heating
Low
Med
Low
Liquid (Flare)
Gas (Frare)
Drain
1Ø, 230V ~, 50Hz
3.6
4.0
63
590
500
450
0 to 50
25
30
28
25
ø25 (I.D.) ; ø32 (O.D.)
Small and compact indoor unit suitable for many applications
Low noise level
7 9
0 to 50
27
Pa
dB(A)
Static pressurerange
Noise level(Low speed)
30
Model
24 25 30
12 14 18
A low noise level has been achieved for each capacity
Static pressure (Pa)
Low static pressuremode
Normal mode
Airflow drop prevention
Low noise realized
Airf
low
18
ARXB07LALHARXB09LALHARXB12LALH
ARXB14LALHARXB18LALH
Compact Duct
ARXB18LALHARXB14LALHARXB12LALHARXB09LALHARXB07LALH
Slim size (217mm) allows installation even where the space behind the ceiling is narrow.
Air-intake at back side makes it possible to reduce the noise effectively.
Compact design
Air-intake
Ultra-slim duct air conditioner for easy installation
Height217mm
Flexible installation
Floor concealedCeiling concealed
Bottom sideBack side
*1
*1: For the air-intake at bottom, the operation noise is larger than the value mentioned in the above table.
Optional partsIR Receiver Unit:Remote Sensor Unit:Auto Louver Grille Kit
*WC : YWC, TWC
UTB-*WCUTD-RS100UTD-GXSA-W (for ARXD07/09/12/14LATH)UTD-GXSB-W (for ARXD18LATH)UTD-GXSC-W (for ARXD24LATH)
19
Slim Duct
•Slim design with drain pump •Increase static pressure range
ARXD07LATHARXD09LATHARXD12LATH
ARXD14LATHARXD18LATHARXD24LATH
Note : Specifications are based on the following conditions.Cooling : Indoor temperature of 27°CDB / 19°CWB, and outdoor temperature of 35°CDB / 24°CWB.Heating : Indoor temperature of 20°CDB / (15°CWB), and outdoor temperature of 7°CDB / 6°CWB.Pipe length : 7.5 m; Height difference between outdoor unit and indoor unit : 0 m.
SpecificationsModel No.
Power source
Air flow rate
Input power
Capacity
Sound pressure level
Dimensions (H x W x D)
Weight
Static pressure range
Standard static pressure
Connection pipe diameter
mm
kg
mm
V/ø/Hz
m3/h
W
kW
dB(A)
Pa
18
High
High
Med
Cooling
Heating
Low
Med
Low
Liquid (Flare)
Gas (Frare)
Drain
1Ø, 230V ~, 50Hz
19
ø25 (I.D.) ; ø32 (O.D.)
7.1
8.0
122
1,330
1,240
1,100
0 to 50
25
35
32
29
198 x 1,100 x 620
27
ARXD24LATH
4.5
5.0
92
800
710
610
0 to 90
25
34
32
28
ARXD14LATH
5.6
6.3
83
940
840
750
0 to 90
25
34
32
28
198 x 900 x 620
23
ARXD18LATH
3.6
4.0
54
600
510
450
0 to 90
25
30
27
24
ARXD12LATH
198 x 700 x 620
ø6.35
ø12.70
2.8
3.2
50
600
550
480
0 to 90
25
29
26
24
ARXD09LATH
2.2
2.8
44
550
490
440
0 to 90
25
28
25
22
ARXD07LATH
ø9.52
ø15.88
Auto Louver Grille Kit (Option)Slim design
Drain port
Height
Drain pump built-in
198mmDrain pump
This model is slim design, it can install at the place where a ceiling is narrow.
Simple flat Auto Louver will provide comfort airflow and harmonize with luxury interior.
Slim Duct
Wired RemoteController
Wireles RemoteController
Auto Louver Grille
Flexible installation
Floor concealedCeiling concealed
Selectable wide range static pressureBy using DC fan motor, it is possible to change the static pressure range 0 to 90Pa. The change of static pressure range is possible by remote controller.
Static pressurerange
0 to 90 Pa24 model is 0 to 50Pa 0
400 500 600 700 800
60
120
Air Flow [m3/h]
(ARXD12LATH)Available air flow rate range @ Hi speed
11 steps
Ext
erna
l Sta
tic P
ress
ure[
Pa]
Air-intakeAir intake direction can be selected to match the installation site.
Depending on the installation site, air-intake at back side makesit possible to reduce the noise effectively.
Bottom sideBack side
Normal
*1
*1: For the air-intake at bottom, the operation noise is larger than the value mentioned in the above table.
20
Optional partsRemote Sensor Unit :Long-Life Filter : Flange (Square) :*WC : YWC, TWC
UTD-RS100 UTD-LF25NA UTD-SF045T
Flange (Round) :IR Receiver Unit :Drain Pump Unit :
UTD-RF204 UTB-*WCUTZ-PX1NBA
INDOOR UNIT
ARXB24LATHARXB30LATHARXB36LATHARXB45LATH
ARXA24LATHARXA30LATHARXA36LATHARXA45LATH
Low Static Pressure Duct Duct
Low Static Pressure Duct/Duct
Note : Specifications are based on the following conditions. Cooling : Indoor temperature of 27°CDB / 19°CWB, and outdoor temperature of 35°CDB / 24°CWB.Heating : Indoor temperature of 20°CDB / (15°CWB), and outdoor temperature of 7°CDB / 6°CWB.Pipe length : 7.5 m; Height difference between outdoor unit and indoor unit : 0 m.
SpecificationsModel No.
Power source
Air flow rate
Input power
Capacity
Sound pressure level
Dimensions (H x W x D)
Weight
Static pressure range
Standard static pressure
Connection pipe diameter
mm
kg
mm
V/ø/Hz
m3/h
W
kW
dB(A)
Pa
1Ø, 230V ~, 50Hz
270 x 1,135 x 700
ø9.52
ø25 (I.D.) ; ø32 (O.D.)
ø15.88 ø19.05ø15.88 ø19.05
High
High
Med
Cooling
Heating
Low
Med
Low
Liquid (Flare)
Gas (Frare)
Drain
12.5
14.0
312
1,720
1,670
1,600
30 to 150
100
43
41
39
ARXA45LATH
11.2
12.5
312
1,720
1,670
1,600
30 to 150
100
43
41
39
45
ARXA36LATH
9.0
10.0
188
1,280
1,210
1,130
30 to 150
100
40
38
36
ARXA30LATH
7.1
8.0
190
1,280
1,210
1,130
30 to 150
100
38
36
34
43
ARXA24LATH
12.5
14.0
338
1,970
1,790
1,670
0 to 80
60
41
38
36
ARXB45LATH
11.2
12.5
253
1,710
1,600
1,470
0 to 80
50
37
35
33
45
ARXB36LATH
9.0
10.0
198
1,410
1,280
1,150
0 to 80
50
34
32
29
ARXB30LATH
1Ø, 230V ~, 50Hz
270 x 1,135 x 700
ø9.52
ø25 (I.D.) ; ø32 (O.D.)
7.1
8.0
145
1,100
920
810
0 to 80
40
31
27
25
43
ARXB24LATH
Optimum model for hotels or bedrooms
Line-up of low-noise and high-power models, compatible with a wide range of static pressure
Static pressure 0
Airf
low
Low Static Pressure Duct type
Low Static Pressure Duct type
Duct type
ARXB30Low
29dB
Max.150Pa
An ultra low-noise model that achieves a quiet interior. Perfect for hotels or bedrooms with limited air duct installation space. Two different levels can be selected according to the static pressure range.
Powerful model with a flexible design
Duct type
With a powerful motor, appropriate for a wide range of static pressure. Flexible air duct installation is possible in a large space such as an office.
Easy maintenance
1.Control box2.Fan casing3.Fan4.Motor
Previous model
2
4
13
Large bottom panel: 1 piece
New model1
4
32
Bottom panel: 2 pieces
Two-direction drain piping
Two-direction drain pipingDuct indoor unit
See below for the case of rear suction type
21
Optional partsLong-Life Filter :IR Receiver Unit :Remote Sensor Unit :*WC : YWC, TWC
UTD-LF60KAUTB-*WCUTD-RS100
High Static Pressure Duct
These indoor units allow for high airflow quantities
ARXC36LATHARXC45LATH
Note : Specifications are based on the following conditions. Cooling : Indoor temperature of 27°CDB / 19°CWB, and outdoor temperature of 35°CDB / 24°CWB.Heating : Indoor temperature of 20°CDB / (15°CWB), and outdoor temperature of 7°CDB / 6°CWB.Pipe length : 7.5 m; Height difference between outdoor unit and indoor unit : 0 m.
SpecificationsModel No.
Power source
Air flow rate
Input power
Capacity
Sound pressure level
Dimensions (H x W x D)
Weight
Static pressure range
Standard static pressure
Connection pipe diameter
mm
kg
mm
V/ø/Hz
m3/h
W
kW
dB(A)
Pa
12.5
14.0
427
3,500
3,000
2,460
100 to 250
100
49
45
42
47
1Ø, 230V ~, 50Hz
400 x 1,050 x 500
ø9.52 (Flare)
ø19.05 (Flare)
ø25 (I.D.) ; ø32 (O.D.)
11.2
12.5
405
2,600
1,950
1,450
100 to 200
100
45
38
32
45
High
High
Med
Cooling
Heating
Low
Med
Low
Liquid (Flare)
Gas (Frare)
Drain
ARXC45LATHARXC36LATH
Low noise design Easy installation (Compact size & Lightweight)A compact size and lightweight indoor unit has been developed by reducing the basic chassis and the overall material weight.
Volume
47.5%down
Weight
40%down
Previous model : 75kg
400
8001,250(unit: mm)
400
5001,050
ARXC36L : 45kg
Cutting off the corners of the conventional indoor unit front panel and fan casing, has enabled less turbulent air flow. Low noise is realized by adopting a plastic case and a plastic fan.
Previous modelNew model (ARXC36L)
Heat exchanger
Plastic fan
Casing (Plastic)
500mm
400m
m
ø225mm
New model:Plastic fan [45dB(A)]
400m
m
Heat exchanger
800mm
Previous model:Metal fan [53.1dB(A)]
Metal fanø240mm
Casing (Metal Sheet)
ARXC36L
45dB(A) (At 100Pa : Actual noise measurement value)
22
Flexible installation Easy maintenance
INDOOR UNIT
AB*A12LBTHAB*A14LBTHAB*A18LBTHAB*A24LBTH
Floor / Ceiling Type
AB* : ABY(FUJITSU), ABH(GENERAL)Note : Specifications are based on the following conditions.
Cooling : Indoor temperature of 27˚CDB / 19˚CWB, and outdoor temperature of 35˚CDB / 24˚CWB.Heating : Indoor temperature of 20˚CDB / (15˚CWB), and outdoor temperature of 7˚CDB / 6˚CWB.Pipe length : 7.5 m; Height difference between outdoor unit and indoor unit : 0 m.Voltage : 230 [V].
SpecificationsModel No.
Power source
Air flow rate
Input power
Capacity
Sound pressure level
Dimensions (H x W x D)
Weight
Connection pipe diameter
mm
kg
mm
V/ø/Hz
m3/h
W
kW
dB(A)
1Ø, 230V ~, 50Hz
199 x 990 x 655
ø25 (I.D.) ; ø32 (O.D.)
ø6.35
ø12.70
ø9.52
ø15.88
High
High
Med
Cooling
Heating
Low
Med
Low
Liquid (Flare)
Gas (Frare)
Drain
7.1
8.0
99
1,000
820
680
47
42
37
AB*A24LBTH
5.6
6.3
74
1,000
720
580
46
39
35
27
AB*A18LBTH
4.5
5.0
42
780
640
550
40
36
34
AB*A14LBTH
3.6
4.0
30
660
570
490
36
32
28
25
AB*A12LBTH
Example for ceiling installation Floor console Under ceilingExample for floor installation
A combination of up/down and right/left directional swing allows three-dimensional air direction control.
Double auto swing
4
4
5
3
3
2
2 1
1
UP and DOWN SWINGRIGHT and LEFT SWING
5 steps selectable
4 steps selectable
• High power• Wide rotation range• High efficiency
High power DC fan motor
(Unit : mm)990 199
655
Symmetrical, slim and compact design.
Compact design
The slim and lightweight design allow the unit to be suspendedfrom the ceiling or installed on the floor. This type suits many room designs
23
Optional partsDrain Pump Unit :Flange :
UTR-DPB24TUTD-RF204
Ceiling Type
AB*A30LBTHAB*A36LBTHAB*A45LBTHAB*A54LBTH
AB* : ABY(FUJITSU), ABH(GENERAL)Note : Specifications are based on the following conditions.
Cooling : Indoor temperature of 27˚CDB / 19˚CWB, and outdoor temperature of 35˚CDB / 24˚CWB.Heating : Indoor temperature of 20˚CDB / (15˚CWB), and outdoor temperature of 7˚CDB / 6˚CWB.Pipe length : 7.5 m; Height difference between outdoor unit and indoor unit : 0 m.Voltage : 230 [V].
SpecificationsModel No.
Power source
Air flow rate
Input power
Capacity
Sound pressure level
Dimensions (H x W x D)
Weight
Connection pipe diameter
mm
kg
mm
V/ø/Hz
m3/h
W
kW
dB(A)
1Ø, 230V ~, 50Hz
240 x 1,660 x 700
ø9.52
ø25 (I.D.) ; ø32 (O.D.)
High
High
Med
Cooling
Heating
Low
Med
Low
Liquid (Flare)
Gas (Frare)
Drain
14.0
16.0
180
2,270
1,780
1,280
51
45
36
AB*A54LBTH
12.5
14.0
131
2,010
1,600
1,230
48
42
35
48
ø19.05
AB*A45LBTH
11.2
12.5
85
1,690
1,400
1,170
45
38
34
AB*A36LBTH
9.0
10.0
66
1,630
1,370
1,140
42
38
33
47
ø15.88
AB*A30LBTH
General installation pattern which suspends the indoor unit from the ceiling.
InstallationOpen
Installation pattern where part of the indoor unit is embedded into the ceiling.
Concealed
Installation which fixes the indoor unit to the wall by the use of wall brackets (Field supplied). This type of installation can be used when the ceiling space is insufficient.
(Field Supplied)
Wall mounted
Auto airflow direction and auto swing
Double auto swing and wide airflow
4
3
2
1
4 steps selectable
5 steps selectable
Up and down
Right and left
Optional drain lift-up mechanism allows flexible installation.
Fresh air intake
Condensate lift-up mechanism (Option)
Indoor
Max.500mm
Easily concealed in any installation
275mm
215mm
New model
790mm
Compact design Air conditioner filter features
More Comfort & Convenience
Long-life* ion deodorization filter
Apple-catechin filter
The filter deodorizes by powerfully decomposing absorbed odors using the oxidizing and reducing effects of ions generated by the ultra-fine-particle ceramic.*The filter can be used for approx. 3 years if it is washed under water to restore its surface action when it is dirty.
Fine dust, invisible mold spores, and harmful microorganisms are absorbed onto the filter by static electricity, and further growth is inhibited and deactivated by the polyphenol ingredient extracted from apples.
Easy maintenance
Removable & washable panel• Powerful cooling & heating by using DC fan motor • Auto-restart function memorizes the operating mode as before,
once the power supply is restored.• Comfortable timer (ON, OFF, PROGRAM, SLEEP)
24
Compact Wall Mounted Type
Simple design with energy saving.
INDOOR UNIT
AS*A07LACHAS*A09LACHAS*A12LACHAS*A14LACH
AS*E07LACHAS*E09LACHAS*E12LACHAS*E14LACH
EEV internal EEV external
AS* : ASY(FUJITSU), ASH(GENERAL)Note : Specifications are based on the following conditions.
Cooling : Indoor temperature of 27°CDB / 19°CWB, and outdoor temperature of 35°CDB / 24°CWB.Heating : Indoor temperature of 20°CDB / (15°CWB), and outdoor temperature of 7°CDB / 6°CWB.Pipe length : 7.5 m; Height difference between outdoor unit and indoor unit : 0 m.Voltage : 230 [V].
SpecificationsModel No.
Power source
Air flow rate
Input power
Capacity
Sound pressure level
Dimensions (H x W x D)
Weight
EV Kit (option)
Connection pipe diameter
mm
kg
mm
V/ø/Hz
m3/h
W
kW
dB(A)
2.2
2.8
15
490
450
370
34
32
26
3.6
4.1
20
560
480
420
38
34
30
4.5
5.0
28
680
490
420
43
35
30
2.8
3.2
16
500
450
370
35
32
26
UTR-EV09XB UTR-EV14XB
2.2
2.8
16
490
450
370
35
33
27
2.8
3.2
16
500
450
370
36
33
27
3.6
4.1
19
560
480
420
39
35
31
4.5
5.0
30
670
490
420
44
37
32
1Ø, 230V ~, 50Hz
275 x 790 x 215
9
ø6.35
ø12.70
ø13.8(I.D.) ; ø15.8-ø16.7(O.D.)
-
1Ø, 230V ~, 50Hz
275 x 790 x 215
9
ø6.35
ø12.70
ø13.8(I.D.) ; ø15.8-ø16.7(O.D.)
High
High
Med
Cooling
Heating
Low
Med
Low
Liquid (Flare)
Gas (Frare)
Drain
AS*E14LACHAS*E12LACHAS*E09LACHAS*E07LACHAS*A14LACHAS*A12LACHAS*A09LACHAS*A07LACH
Ion Deodorization Filter
Apple-catechin Filter
Pre Filter
Organic coating fin used heat exchanger
Antibacterial deodorizing pre-filter with special ceramic powder
Long-life* Ion Deodorization Filter
Apple-catechin Filter
Using different filters at both sides
The filter deodorizes by powerfully decomposing absorbed odors using the oxidizing and reducing effects of ions generated by the ultra-fine-particle ceramic.
Fine dust, invisible mold spores, and harmful microorganisms are absorbed onto the filter by static electricity, and further growth is inhibited and deactivated by the polyphenol ingredient extracted from apples.
(*The filter can be used for approx. 3 years if it is washed under water to restore its surface action when it is dirty.)
25
“Vertical airflow” provides powerful floor level heating
Air conditioner filter features
Wall Mounted Type
Simple & Elegant Appearance Design
AS*A18LACHAS*A24LACHAS*A30LACH
AS* : ASY(FUJITSU), ASH(GENERAL)Note : Specifications are based on the following conditions.
Cooling : Indoor temperature of 27˚CDB / 19˚CWB, and outdoor temperature of 35˚CDB / 24˚CWB.Heating : Indoor temperature of 20˚CDB / (15˚CWB), and outdoor temperature of 7˚CDB / 6˚CWB.Pipe length : 7.5 m; Height difference between outdoor unit and indoor unit : 0 m.Voltage : 230 [V].
SpecificationsModel No.
Power source
Air flow rate
Input power
Capacity
Sound pressure level
Dimensions (H x W x D)
Weight
Connectionpipe diameter
mm
kg
mm
V/ø/Hz
m3/h
W
kW
dB(A)
High
High
Med
Cooling
Heating
Low
Med
Low
Liquid (Flare)
Gas (Frare)
Drain
8.0
9.0
91
1,240
980
770
52
45
35
AS*A30LACH
1Ø, 230V ~, 50Hz
7.1
8.0
64
1,100
910
730
48
43
35
320 x 998 x 228
15
ø9.52
ø15.88
ø12 (I.D.) ; ø16 (O.D.)
AS*A24LACH
5.6
6.3
35
840
770
690
41
39
35
AS*A18LACH
Easy maintenance
“Horizontal airflow” does not blow cool air directly at the occupants in the room
Power diffuser
Power diffuser (full open)
46o
(24/30)
(24/30)
Simplification of drain pan cleaning improves maintenance-ability.
33 32 31 30 29
(˚C)
(24/30)
Vertical airflow
Outside air conditions: 2°C 60%Operation contents: HeatingSet temperature (Max set temp) 30°C, Air flow HiVertical flap: DownwardHorizontal flap: Center
00 3 6 9 12(m)
1
2.1(m)
(˚C)
15 16 17 18
(24/30)
Horizontal airflow
Outside air conditions: 35°C 40%Operation contents: CoolingSet temperature (Min set temp) 18°C, Air flow HiVertical flap: UpwardHorizontal flap: Center
00 3 6 9 12(m)
1
2.1(m)
26
CONTROLLER
SystemAir ConditioningCentral Control
Air ConditioningIndividual Control
Outdoor unit
Indoor unit
Signal AmplifierUTY-VSGX
General-purpose Building Control Computer
BuildingManagement
Service Tool (Software)UTY-ASGX
USBAdaptor
NetworkConvertor
UTY-VGGX
Card-key
(Field supplied)
(Field supplied)
For single split
Connectable tovarious sized BMS/BAS
NetworkConvertorUTY-VGGX
Web Monitoring Tool (Software)UTY-AMGX
(VRF system side)
Internet orPublic Telephone Line
(Monitoring side)
or
IR Receiver UnitUTB-YWC
Remote/Monitoring side
Internet or PublicTelephone Line
IR Receiver KitUTY-LRH*B1
Wired Remote ControllerUTY-RNK*
External Switch ControllerUTY-TEKX
Network Convertor(BMS / LONWORKS®)UTY-VLGX
System Controller (Software)UTY-APGX
Simple Remote ControllerUTY-RSK*
Simple Remote ControllerUTY-RHK*Without master control
Wireless Remote ControllerUTY-LNH*
The V-II system supports every users needs by offering a variety of Control systems,including individual control, central control and building management control options.
System diagram
*2USB
Adaptor
(Field supplied)
*2
USBAdaptor
(Field supplied)
*2
*1
USBAdaptor
(Field supplied)
*2
BACnet ® Gateway (Software)UTY-ABGX
Group Remote ControllerUTY-CGG*
Touch Panel ControllerUTY-DTG*
*1. BMS/BAS: Building Management System / Building Automation System*2. USB Adaptor is U10 USB Network Interface of Echelon® Corporation.
Transmission line (VRF Network)Remote controller lineUSB cable
LONWORKS® NetworkEthernetSignal line(Single split system)
The devices above cannot be connected to the S series. (Except System Controller & BACnet® Gateway)
Central Remote ControllerUTY-DCG*
Control Systems
* : Y(FUJITSU), G(GENERAL)
Group Remote Controller line
27
Max. controllable remote controller groups
Max. controllable indoor units
Max. controllable groups
On / Off
Operation mode setting
Fan speed setting
Room temp. setting
Room temp. set point limitation
Test operation
Up/down air direction flap setting
Right/left air direction flap setting
Group setting
RC prohibition
Anti freeze setting
Economy mode setting
Failure
Defrosting
Current time
Day of week
R.C. prohibition
Cooling/heating priority
Address display
Schedule timer
On/off timer
Sleep timer
Program timer
Day off
Min. unit of timer setting (Minutes)
Status monitoring system
Electricity charge calculation
Error history
Emergency stop
Control via internet
E-mail notification for malfunction
Item
Model name
Air
cond
ition
ing
cont
rol f
unct
ion
Dis
play
Tim
erC
ontr
ol
Period
On/off per day
On/off per week
Central RemoteController
100
100
16
-
-
-
-
-
-
-
-
-
-
Week
20
140
-
-
-
2
10
-
-
-
-
-
-
UTY-DCG*
Touch PanelController
400
400
400
Year
20
140
-
-
-
10
-
-
-
UTY-DTG*
*3
Comparison table of Controllers
K*:KY(FUJITSU), KYT(FUJITSU), KG(GENERAL), H*: HY(FUJITSU), HG(GENERAL), G*: GY(FUJITSU), GG(GENERAL)*1 "Operation mode" setting is not available for this model.*2 In the case of connection constitution for only J-II.*3 This function is available only through external input. control.
System Controller
1600
1600
1600
-
Year
72
504
-
-
-
10
-
UTY-APGX
Software
*3
Group RemoteController
8
18
-
-
-
-
-
-
-
-
-
-
-
Week
4
28
-
-
-
-
10
-
-
-
-
-
-
UTY-CGG*
*2
Wireless RemoteController
1
9
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
5
-
-
-
-
-
-
UTY-LNH*
*2
*1Simple RemoteController
1
9
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
UTY-RHK*
*2
Simple RemoteController
1
9
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
UTY-RSK*
*2
Wired RemoteController
1
9
-
-
-
-
-
Week
4
28
-
-
30
-
-
-
-
-
UTY-RHK*
*2
CONTROLLER
28
The room temperature can be controlled by detecting the temperature accurately from the built-in sensor•Simple operation with Built-in Weekly / Daily Timer.•Control up to 9 indoor units.•Up to 2 wired remote controllers can be connected to a single indoor unit.
•A large On / Off button is provided in the centre of the remote controller for easy operation.
•Background light enables easy operation in a darkened room.
•Following an error display, diagnostics can be carried out on the controller.
User-friendly operation
Built-in timers
Wired Remote Controller
Simple Remote Controller
Compact remote controller provides access to basic functions
UTY-RSK*UTY-RHK* (Without ability to change operation mode)
•Up to 9 indoor units can be controlled with one remote controller.•Suitable for hotels or offices as it is easily operated with no complex functions.
Weekly timer: Possible to set ON/OFF time to operate twice each day of the week.Setback timer: Possible to set temperature for two times spans and for each day of the week.At "Weekly timer" + "Set back timer" setup
Indoor temperature can be detected accurately by the inclusion of a thermo sensor in the body of the wired controller. This new wired remote controller and the optional remote sensor allows flexibility in sensor location, suitable for all requirements.
Accurate and comfortable
Example of changing sensorRemote Sensor in the bedroom
Wired Remote Controller in the living room
Wired remotecontroller
Indoor unit
Remotesensor
The detecting point can be easily changed
Day Night
Displayed temperature is set temperature.
Max. controllable
9indoor units
Max. controllable
9indoor units
Functions
*1: "Operation mode" setting is not available. It is recommend to use together with other type controller.
Two methods are available for determining the cause of failure in the event of a malfunction occurs:
Diagnosis check function
Simple installationComponents are compatible with standard switch boxes. Flat back surface allows to be installed wherever it is needed.
Model
On / Off
Fan control
Operation mode
Room temp. setting
UTY-RSK* UTY-RHK*
*1
UTY-RNK*
Model No.
SpecificationsUTY-RNK*
DC 12V
120 x 120 x 18
160
UTY-RSK*
DC 12V
120 x 75 x 14
90 (100 : UTY-RSKYT)
UTY-RHK*
DC 12V
120 x 75 x 14
90 (100 : UTY-RHKYT)
Power Source
Dimensions (H x W x D) (mm)
Weight (g)
DC12V is supplied by the indoor unit.K*: KY(FUJITSU), KYT(FUJITSU), KG(GENERAL)
UTY-RSK* UTY-RHK*Without ability to
change operation mode
29
UTY-LNH*
•A single controller controls up to 9 indoor units.
Max. controllable
9indoor units
Selectable
4daily timers
Simple and sophisticated operations with a choice of 4 daily timers
UTY-LNH*
Wireless Remote Controller
Model No. UTY-LNH*
1.5V (R03 / LR03 / AAA) x 2
158 x 56 x 20
70
UTB-*WC
DC 12V
122 x 60 x 26.5
150
UTY-LRH*B1
DC 12V
213.8 x 213.8x 25.7
140
Battery or Power source
Dimensions (H x W x D) (mm)
Weight (g)
Specifications
DC12V is supplied by the indoor unit.H*: HY(FUJITSU), HG(GENERAL)
Cassette type indoor unit can be controlledwith Wireless Remote Controller
WirelessRemote Controller IR Receiver Kit
UTY-LRH*B1
IR Receiver Kit
UTB-*WC
Necessary to control for all duct type by Wireless Remote Controller
IR Receiver Unit
Duct type indoor unit
WirelessRemote Controller
IR Receiver Unit
Built-in timersSelect from 4 different timer programs: On / Off / Program / Sleep Program timer: The program timer operates the ON and OFF timer once within a 24 hour period.Sleep timer: The sleep timer function automatically corrects the set temperature according to the time setting to prevent excessive cooling or heating during sleep hours.
System addressingDuring installation work, system addressing can be performed using the Wireless Remote Controller, thus eliminating manual switch setting.
WirelessRemote Controller
Indoor unit
Transmission line
Outdoor unit
*WC : YWC, TWC
Easy operation settingCode selector switch prevents indoor unit mix-up. (Up to 4 codes can be set.)
Wide and precise
CONTROLLER
30
Group control of indoor units with simple operation
UTY-CGG*
•Up to 8 remote controller groups can be controlled by one Group Remote Controller.
•Up to 64 Group Remote Controllers can be connected in one VRF network system.
Group Remote Controller Max. controllable
64group R.C. in a VRF
network system
Max. controllable
8remote
controller groups
SpecificationsModel No. UTY-CGG*
DC 12V
120 x 120 x 18
200
Power Source
Dimensions (H x W x D) (mm)
Weight (g)
DC12V is supplied by a network converter.G*: GY(FUJITSU), GG(GENERAL)
•Network Convertor is required to connect Group Remote Controllers to a VRF network system.
(Network Convertor allows up to 4 Group Remote Controllers) Network Convertor
ON / OFF, Operating mode, Room temperature and Fan speed setting can be controlled / monitored centrally or individually.
High performance and compact sizeThe weekly timer is provided as a standard function.1. The timer can be set up for up to 4 times per day. (On / Off,
operating mode, set temperature)2. Allows separate settings for each day of the week.
Built-in weekly timers
Centralcontrol
ON/OFFcontrol
Weeklytimer
•Single Group Remote Controller controls and monitors up to 8 remote controller groups.
Control up to 8 remote controller groups
UTY-VGGX
Hotel
Restaurant
Lobby
Office & Lounge
NetworkConvertor
1
2
Group RemoteController
Group Remote Controller 1 : To control office floor and hotel floor (8 remote controller groups).Group Remote Controller 2 : To control hotel floor (5 remote controller groups).
Office floor
Wired Remote Controller
Office room
WirelessRemote
Controller
Meeting room
Hotel floor
WirelessRemote
Controller
Office room
Guest room
Simple RemoteController
Restaurant
Wired RemoteController
Lobby
WiredRemote
Controller
31
UTY-DCG*
Central Remote Controller
Max. controllable
16groups
Max. controllable
100Indoor units
SpecificationsModel No. UTY-DCG*
Power Source
Dimensions (H x W x D) (mm)
Weight (g)
PACKING LIST
Packing List
Control Panel
DC 5 V
120 x 162 x 26
308
Power Supply Unit
100-240V, 50-60Hz, Single phase
99 x 135 x 40
355
Control Panel / Power Supply Unit / Connecting cable, etc.
G*: GY(FUJITSU), GG(GENERAL)
Central control of small- and medium-sized buildings and tenants.
• Individual control and monitor of 100 indoor units • 5 inch TFT color screen • User friendly view and easy operation • Automatic display switching for the number of connected units • Operation guidance display • Automatic switching of function menu• Corresponds to 7 different languages like English, Chinese, French, German, Spanish, Russian, Polish.
• It allows multiple indoor units grouping (Max.16 groups controlled)• Interlock with external device
• External input / output contact • Detachable power supply unit
System overview
Functions
Group : Division A Group : Division B
Group : Hallway
Group : Division C
Group : 3F
Emergency stop functionGroup : Tenant A Group : Tenant B Group : Tenant C
Group : 2F
• Individual control• Remote controller prohibition (All, On/Off,Mode, Temp.,Timer,Filter)• Room temperature set point upper and lower limitation
Diverse control of indoor units
• The control panel and power supply unit can be installed separately.
• For flexibility in installation, the Control panel can be built into the wall or fix on the wall.
Easy Installation
Control panel + Power supply unit
Control panel
CeilingPower supply unit
Power supplyunit
Wall
Wall
Controlpanel
SW BOX
Setting pattern 1 Setting pattern 2
Weekly timer
Weekday28°C 28°C26°C26°CSet temp.
Weekend 26°C26°C
Time8:00 12:00 13:00 18:00 21:00
Holiday 28°C28°C
Automatic clock adjustment
CONTROLLER
32
UTY-DTG*
Touch Panel Controller
•Large-sized 7.5-inch TFT color•LCD Easy finger touch operation•Stylish shape and design to suit all application•No additional component is required for installation•Up to 400 indoor units can be controlled•Selectable 2 display types (Icon / List) in monitoring mode•Corresponds to 7 different languages, English, Chinese, French, German, Spanish, Russian, Polish.
Max. controllable
400indoor units
Real size screen image
• Large and wide-angled LCD is easily viewable even at a distance• Easy-to-understand icon-driven Graphical User Interface (GUI)• Wide range of simple-to-understand icons
• Operation can be selected using your finger or the dedicated touch pen by pressing the appropriate on-screen icon
• Up-to-date status display• Background color identifies current control operation Blue for
monitoring, green for operational control• Flat touch screen is easily cleaned• Non-glare coating on touch panel controller minimizes fingerprint
marking
Easy operation
Data transfer availableby USB
CSV format data edited by PC can be imported to Touch Panel Controller.
Versatility
33
SpecificationsModel No. UTY-DTG*
100-240V 50/60Hz
260 x 246 x 54
2,150
USB 2.0
Power Source
Dimensions (H x W x D) (mm)
Weight (g)
Interface
G*: GY(FUJITSU), GG(GENERAL)
Group A Group B
Up to 400 indoor units can be controlled
System overview
Emergency stop controlAir conditioner can be turned off through the external input control
It allows multiple indoor unit grouping
Emergency stop function
• Up to 400 indoor units can be controlled• It allows multiple indoor units grouping• Schedule timer function is standard (20 patterns per day)• Emergency stop function(through the external input control)• Temperature upper and lower limit setting• The clock of each indoor unit correct setting
Functions
Touch Panel Controller is easily mounted to the wall. Flat back surface allows to be installed wherever it is needed.• Correctable mechanism for tilting (horizontal) after the installation of the body
No additional component is required for installation
• There is no need for the installation space of power supply adaptor and transmission adaptor etc.
Easy installation & maintenance
Flexible groupingIndividual control
Schedule control Indoor units operation monitoring
Automatic clock adjustment
The time setting of each controller can be set in batch automatically.
Switch boxMounted plate
Easy-to-remove front cover
UTY-APGX
System Controller
User friendly view and operation
System Controller realizes the advanced integrated monitoring & control of VRF network system from small scale buildings to large scale buildings.
Monitor mode (Site)
Monitor mode (Building)
Monitor mode (Floor) Monitor mode (List) Schedule setting
Main operation monitoring screen Management functions Operation monitoring of each siteMonitoring located site
Max. controllable
1,600indoor units
Max. controllable
400outdoor units
Max. controllable
4VRF network systems
Software
• Up to a maximum of 4 VRF network systems, 1600 indoor units, and 400 outdoor units can be controlled.
• Supports VRF S series, V series, V-ll series and J-II series. • In addition to air conditioning precision control function, central remote control, electricity charge calculation, schedule management, and energy saving functions are strengthened and building manager and owner needs are met.
• Corresponds to 7 different languages (English, Chinese,French, German, Spanish, Russian, Polish)
On site central control
Remote central controlSystem Controller may be used on site or remotely over various networks for remote central control. System Controller requires 2 softwares working together. VRF Controller runs on site and communicate with VRF system. VRF Explorer runs remotely and provides user interface and communicate with the VRF Controller. VRF Controller and VRF Explorer program may run in a single PC or in different PCs separated by network. By using VRF Explorer software, one PC can perform central control of 10 VRF system sites with max. 20 buildings per site.
Remote centralized control
Max. 4 VRF network systems per site
Building Management Company A (In charge of the day shift)
Internetor
Telephone Lineor
LAN
Internetor
Telephone Lineor
LAN
Building management company,management center, etc.
BuildingManagement Company B
(In charge of the night shift)
Security Company
Headquarters Management Center
A maximum of 10 locations, such as offices or factories
1 VRF Explorer can control or monitor up to 10 sites.
1 VRF Controller can be monitored from any number of VRF Explorers (Up to 5 connections simultaneously).
Office Management Center
VRF Explorer
VRF Explorer
VRF Explorer
VRF ExplorerVRF Explorer
VRF Explorer
VRF Controller
VRF Controller
Internetor
Telephone Lineor
LANVRF Explorer
VRF Controller
Central Monitoring Screenfor all Properties
Special Property Detailed Monitoring Screen
34
CONTROLLER
35
•Batched stop•Divers control of indoor units•Oprating & control record•Schedule control•Error display & E-mail nitification•Prohibition setting
Others
FunctionsEnergy saving management UTY-PEGX:software
Pow
er c
onsu
mpt
ion
Time
Outdoor unit capacityupper limit
Peak cut operationControls overall operation while maintaining comfort according to the overall power consumption target value.
Apportions the power used by indoor and outdoor units and automatically calculates the electricity charge for each tenant.When you want to calculate the power used during a certain period in hotels, etc., computation linked with an electric meter is also possible. (Option)
Outdoor unit capacity saveSets an upper limit of outdoor unit capacity and performs capacity save operation at peak times.
Indoor unit rotation operationReduces annual power consumption by operating indoor units in rotation.
Forced thermostat off range
Target power consumption
Outdoor unit stop range
Outdoor unit capacity control screen
Ideal control line (Use of average power consumption)
Shows change in power consumption by time
Indoor unit rotation screen
Electricity charge apportionment
OptionBilling management for users for a set period of time, such as for hotels
Signal transmission line
1Ø, 2wire 230V, 50Hz
DPM
System Controller
Outdoor unit
Room 301 Room 302 Room 303
Room 201 Room 202 Room 203
Room 101 Room 102 Room 103
CT
1Ø, 2
wire
23
0V, 5
0Hz
Option
SpecificationsModel No. UTY-APGX
Personal Computer
Operating System
CPU
HDD
Memory
Interface
Accelerator
Other Software Required
AT compatible machine that runs Microsoft® Windows®
Microsoft® Windows® XP Professional (Service Pack 3 or later / English version),Microsoft® Windows Vista® Home Premium, Business (Service Pack 2 or later / Corresponds to 7 different languages.*),Microsoft® Windows® 7 Professional (64-bit is not supported. / Corresponds to 7 different languages.*)*English, Chinese, French, German, Spanish, Russian, Polish
Intel® Pentium® / Celeron 2 GHz (VRF Controller), 1 GHz (VRF Explorer) or higher
40 GB or more of free space (5 GB for VRF Explorer PC)
2 GB or more (VRF Controller), 1 GB or more (VRF Explorer)
USB port is required for each of the followings for Server PC ;• Wibu Key (Software protection key) • Echelon® U10 USB Network Interface (Required for each VRF Network)Ethernet port is required for remote connection using internet.
Adobe® Reader® 9.0 or later
Requires the internal graphics accelerator be compatible with Microsoft® DirectX® 9.0
PACKING LIST
Wibe Key
CD-ROM
Personal computer must be field supplied. U10 USB Network Interface must be field supplied. Contact Echelon® Corporation or its local sales representative for detail.Product Name : U10 USB Network Interface - TP/FT-10 Channel Model Number: 75010R
Includes the software for System Controller. Both VRF Controller and VRF Explorer software is included.
Software protection key to be inserted in a USB slot running System Controller.System Controller may only run on a PC with Wibu Key. Remote VRF Explorer software does not require Wibu Key.
36
CONVERTOR & ADAPTOR
UTY-VGGX
Network Convertor
•Split type systems can be controlled from a central remote controller or PC controller through connection to the VRF's network convertor. •Standard remote controller and central remote controller provide On / Off control, master control, temperature and fan control, etc.•A single network convertor can be used to connect and control up to 16 single units.
Installation example
•This network convertor is to be used for connecting single split system or group remote controller with the VRF network system.
•Please select the function by switching the dip switch during the installation.
* 2 refrigerant circuits can be covered by a single network convertor. Up to a total of 16 network convertors, Central remote controller and Touch panel controllercan be connected in one VRF network system.
Used for connecting Group Remote Controller
Big Multi
VRF networksystem
System Controller Single Split
Group of Single Split
4 group remort controllers can be connected to a single Network convertor.
VRF networksystem
Network Convertor
Group Remote Controller
Please consult your distributor for connectable split type air conditioner. Up to 100 network convertors may be connected in a single VRF network system. A single network convertor is considered as a single refrigerant system, irrespective of the number of connected single models.
Network Convertor
USBadaptor
SpecificationsModel No. UTY-VGGX
50-60Hz 220-240V
8.5
67 x 288 x 211
1,500
Power Source
Power Consumption (W)
Dimensions (H X W X D) (mm)
Weight (g)
Model No. UTY-VLGX
220-240V 50/60Hz
4.5
67 x 288 x 211
1,500
Power Source
Power Consumption (W)
Dimensions (H X W X D) (mm)
Weight (g)
37
Network Convertor for LONWORKS®
BACnet® Gateway
Installation example
UTY-VLGX
•For connection between VRF network system and a LONWORKS® open network for management of small to medium-sized BMS and VRF network system.
•The unit permits central monitoring and control of a VRF network system from a BMS through a LONWORKS® interface.•Up to 128 Indoor units can be connected to one Network Convertor for LONWORKS®
Transmission specifications (BMS side)
UTY-ABGX
•The VRF network system can be incorporated into a Building Management System.•Enables central control of up to 1,600 indoor units through BACnet®, a global standard for open networks. •Conforms to ANSI / ASHRAE Standards® 135-2004 BACnet® Application Specific Controller (B-ASC) BACnet® / IP over Ethernet.
•Connects up to 4 VRF network systems (1,600 indoor units / 400 outdoor units) per gateway.•Supports VRF S/V series, V-II series and J-II series
78kbps
FT-X1 (Echelon® Corporation)
Free topology
None(It attaches at the terminal of a network.)
Transmission speed
Transceiver
Transmission way form
Terminal resistor
Software
CD-ROM(Software)
SoftwareProtection Key
Installation example
Lighting facilities
Security system
Automatic fire alarm interface
Ventilation system
BACnet Operator Workstation (B-OWS)
USB adaptor (Field supplied)
USB adaptor (Field supplied)
USB adaptor (Field supplied)
USB adaptor (Field supplied)CD-ROM
(Software)Software
Protection Key
(UTY-ABGX)BACnet Gateway
Outdoor unitIndoor unit
VRF network system 1
VRF network system 2
Indoor unit
BACnet
Max. 4 VRF network systems
*1: USB adaptor is U10 USB Network Interface of Echelon® Corporation.
®
®
®
= BACnet® Gateway for each system.= USB cable= Transmission line (VRF Network)= Ethernet
*1
Outdoor unit
Max. controllable
128indoor units
Max. controllable
4Units to BMS
Max. controllable
4VRF network systems
Max. controllable
400outdoor units
Max. controllable
1,600indoor units
General-purpose building control computer(LONWORKS® device)
LONWORKS® Network
NetworkConvertor
VRF network system 1 Lighting facilities
Security system
Automatic firealarm interface
Ventilation system
Max. 128 indoor unitsMax. 100outdoor units
Max. 4 NetworkConvertor
VRF network system 2
Max. 128 indoor unitsMax. 100outdoor units
The BACnet Gateway version 2.0 is eligible to display BTL Mark. Founded by BACnet International, BTL (BACnet Testing Laboratories) is an indication of worth trusting for its quality after passing the strict tests.
SpecificationsModel No. UTY-ABGX
Personal Computer AT compatible machine that runs Microsoft® Windows®
Microsoft® Windows® XP Professional (Service Pack 3 or later / Corresponds to 7 different languages.*)Microsoft® Windows Vista® Home Premium, Business (Service Pack 2 or later / Corresponds to 7 different languages.*)Microsoft® Windows® 7 Home Premium, Professional (Corresponds to 7 different languages.*)*English, Chinese, French, German, Spanish, Russian, Polish•64-bit version of Windows® are not supported.
Intel® Pentium® / Celeron®, AMD Athlon / Duron processor 2 GHz or higher
40 GB or more of free space
2 GB or more
USB port (x 2-5) is requiredEthernet port is required
Adobe® Reader® 9.0 or later
PACKING LIST
Packing List
Personal computer must be field supplied. U10 USB Network Interface must be field supplied. Contact Echelon® Corporation or its local sales representative for detail.Product Name : U10 USB Network Interface - TP/FT-10 Channel Model Number : 75010R
CD-ROM / Wibu Key
Operating System
CPU
HDD
Memory
Interface
Other Software Required
38
Signal Amplifier
CONVERTOR & ADAPTOR
UTY-VSGX
Installation example
•Transmission Line length can be extended up to 3,600m for with multiple Signal Amplifiers.
•Up to 8 signal amplifiers can be installed in a VRF network system.•A signal amplifier is required,(1) When the total wiring length of the transnission line exceeds 500m.(2) When the total number of units on the transnission line exceeds 64.
UTY-TEKX
Installation exampleAuto mode operation, which switches the cooling and the heating automatically, is enabled by using the sensor switch and External Switch Controller. Note: All indoor units will operate in the same mode.
B
AE
Signal Amplifier
C
Electrical wiring
•In combination with a field supply Card-Key Switch or other sensor, the External Switch Controller allows control of the ON / OFF, Room temperature, Fan speed and Master control functions. This makes this product suitable for installations such as hotel rooms.
•Card-key or other sensor switches are available as a field supplied parts.
Air conditioner switching can be controlled by connecting other sensor switches
RemoteController
Line
Indoor Unit 1 2 3 E COM SW1 SW2
Card-key
Externalinput
RemoteController
Line
Indoor Unit 1 2 3 E COM SW1 SW2
Sensor SW
Externalinput
Card-key(Field supplied)
Sensor SW(Field supplied)
External Switch Controller
External Switch Controller
Note 1. Please choose a thermosensor switch which can be set up for T1 and T2.
Note 2. The remote controller's operation is prior to the auto mode operation.
Roo
m te
mp.
Time
T1
T2
Cooling
Heating
SU MO TU WE TH FR SA
7
3 126 9 15 18 21
T1 = ON, T2 = OFF
To individual dry contact
Sensor SW(Field supplied)
External Switch Controller (UTY-TEKX)
SpecificationsModel No. UTY-VSGX
220-240V 50/60Hz
4.5
67 x 288 x 211
1,500
Power Source
Power Consumption (W)
Dimensions (H X W X D) (mm)
Weight (g)
Model No. UTY-TEKX
DC 12V
120 x 75 x 30
90
Power Source
Dimensions (H X W X D) (mm)
Weight (g)
DC12V is supplied by the indoor unit.
External Switch Controller
39
SERVICE & MONITORING
SpecificationsModel No.
Personal Computer
UTY-AMGXUTY-ASGX
AT compatible machine that runs Microsoft® Windows®
UTY-ASGX
UTY-AMGX
Wiring connection
•Operation status can be checked and analyzed to detect even the smallest abnormalities•Storage of data on system operation status on a PC allows access even from off site.•Up to 400 indoor units (a single VRF network system) can be controlled and monitored for large scale buildings or hotels•This software can be connected to any point of transmission line with USB adaptor (field supplied).•Supports VRF S/V series, V-II series and J-II series.
Extensive monitoring and analysis functions for installation and maintenance
Software
•Troubleshooting is performed by monitoring each air conditioning unit remotely during periodical system checks.•Error notification can be automatically transmitted to several locations using the internet*1.•Requires either a dedicated internet connection or public telephone line.•Determination of an error occurrence can be made through error warnings and equipment status information obtained from a remote location.•The monitoring data in a remote side can be optionally downloaded. And, this data can be displayed in offline mode of the service tool.•Monitoring side computer is not required to install special software, requires only general web browser.•Supports VRF S/V series , V-II series and J-II series.
Product features
(Field supplied)
Refrigerant piping
Tran
smis
sion
line
Indoor unit
Indoor unit
USB adaptor(Field supplied)
Functions•Equipment Detail (Diagram)
Support 4 VRF network systemsUSB adaptor (max. 4 adaptors per PC) permit, monitoring of up to 1,600 indoor units.Suitable for large-scale buildings or hotels.
VRF NetworkSystem 2
VRF NetworkSystem 3
VRF NetworkSystem 4
Indoor unitMax. 400
Indoor unitMax. 400
Indoor unitMax. 400
Indoor unitMax. 400
Web Monitoring System
Indoor unit
Transmission line
USB adapter(Field supplied)
Outdoor unit
WebMonitoring
Tool
USB adaptorsVRF Network System SideMonitoring Side
orInternet
PublicTelephone
Line
*1: Use of internet mail system required.
Max. Monitorand controll
100outdoor units
Max. Monitorand controll
400indoor units
VRF network systemcan be supported
41,600indoor units
can be supported
VRF NetworkSystem 1
Operating System
CPU
HDD
Memory
Interface
Software
Hardware
Microsoft® Windows® XP Professional (English version / Service pack 3 or later), Microsoft® Windows® Vista® Home Premium,Business Edition (English version), Microsoft® Windows® 7 Professional (64-bit is not supported. / English version)
1 GB (Vista, 7), 512 MB (XP) or more
USB port for U10 USB Network Interface and Software protection key. USB port (for U10 USB Network Interface Max.4, Software protection key)Following interface is required for remote connection:Public Telephone LIne : Modem is requiredInternet using LAN : Ethernet port is required
1 GB or more
Internet Explorer 6.0 or 7.0 or 8.0 / Adobe® Reader® 9.0 or later
CD-ROM drive
Intel® Pentium® / Celeron®, AMD AthlonTM / DuronTM 1 GHz or higher
10 GB or more of free space 40 GB or more of free space
PACKING LIST
Packing List
Personal computer must be field supplied. U10 USB Network Interface must be field supplied. Contact Echelon® Corporation or its local sales representative for detail.Product Name : U10 USB Network Interface - TP/FT-10 Channel Model Number: 75010R
CD-ROM / Wibu Key
Service Tool
SoftwareWeb Monitoring Tool
•Equipment Detail (List)•Operation History•Error History•Remote File Download•System List•Commissioning Tool•Network Topology Analyzer
•Remote setting•System Time Setting•Central Release•Model Name Writer•Error Memory Reader•Time Guard Information•Software Version acquire and display
OTHERS
40
RFA data
Two kinds of model data, DXF data and RFA data, necessary in detailed design are offered. These data can be procured from the Fujitsu General web site and Design Simulator
2. 2D (DXF), 3D (RFA) contents data
FGL Web site
Design Simulator
for
FUJITSU VRF
Fujitsu General offers software which quickly performs model selection and creates material for model estimation in the VRF initial design stage. "Design Simulator" has functions which automatically select the proper model for the required capacity, automatically draft piping diagrams and wiring diagrams, and also automatically calculate the additional refrigerant charge amount, automatically generates the reports necessary for estimation. Operation is also easily performed by drag & drop and full-fledged model design estimates can be quickly made.
• Automatic model selection of indoor unit and outdoor unit• Simple drag & drop operation• Automatic generation of piping diagrams and wiring diagrams• Automatic calculation of additional refrigerant charge amount• Auto CAD Data (DXF), Revit Mep Data (RFA) export • Automatic report generation (Word, Excel)• Multi-language capability
Features
1. Quick model selection and design tool "Design Simulator" for VRF
VRF System Design
41
Optional Parts
Controllers
Convertors / AdaptorsBACnet® Gateway
Wired Remote ControllerUTY-RNK*
Wireless Remote Controller
Simple Remote ControllerUTY-RSK*With operation mode
Simple Remote ControllerUTY-RHK*Without operation mode
UTY-LNH*IR Receiver UnitUTB-YWCUTB-TWC
For All Duct type
IR Receiver KitUTY-LRH*B1
For Cassette type
Group Remote ControllerUTY-CGG*
Network ConvertorUTY-VGGX
Network Convertor
Central Remote ControllerUTY-DCG*
for LONWORKS®
UTY-VLGXUTY-ABGX
Signal AmplifierUTY-VSGX
External Switch ControllerUTY-TEKX
Software
System ControllerUTY-APGX
Software
Touch Panel ControllerUTY-DTG*
K*:KY(FUJITSU), KYT(FUJITSU), KG(GENERAL), H*: HY(FUJITSU), HG(GENERAL), G*: GY(FUJITSU), GG(GENERAL)
CD-ROM (Software)
Software Protection Key
OTHERS
42
Optional Parts
Connection Tube
Gas Pipe
Liquid Pipe
Gas Pipe
Liquid Pipe
Header
Model name3-6 Branches
UTR-H0908L
UTR-H0906L
3-8 Branches
UTR-BP090XSeparation Tube
UTR-H0908LHeader
UTR-H0906L
Gas Pipe
Liquid Pipe
Header
Others
FlangeRound
Square
RemoteSensor Unit
Long-Life Filter
Auto Louver Grille Kit
DrainPump Unit
Air Outlet Shutter Plate
Insulation Kit for High Humidity
EV Kit
Fresh AirIntake Kit
Wide Panel
Panel Spacer
Grill Kit
Indoor unit typeCompact
Duct Slim Duct Low StaticDuct Duct High Static
DuctCompactCassette
SlimCassette Cassette Floor /
Ceiling Ceiling Compact WallMounted
WallMountedItem
UTZ-PX1BBA
UTD-RS100 UTD-RS100
-
-
-
-
-
-
-
-
-
-
-
UTD-GXSB-W UTD-GXSC-W
-
-
-
-
-
-
-
-
-
-
-
UTD-LF25NA
UTD-RF204
UTD-SF045T
UTD-RS100
UTZ-PX1NBA
-
-
-
-
-
-
-
-
UTD-LF25NA
UTD-RF204 UTD-RF204
UTD-SF045T
UTD-RS100
UTZ-PX1NBA UTR-DPB24T
-
-
-
-
-
-
-
-
UTR-EV14XBUTR-EV09XB
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
UTD-LF60KA
UTD-RS100
-
-
-
-
-
-
-
-
-
-
-
UTR-YDZB
UTG-UFYC-W
UTZ-KXGC
UTZ-VXAA
-
-
-
-
-
-
-
-
-
UTG-AGYA-W
UTR-YDZC
UTG-UGYA-W
UTZ-KXGB
UTZ-VXGA
UTG-BGYA-W
-
-
-
-
-
-
-
UTG-AGYA-W
UTR-YDZC
UTG-UGYA-WUTG-UFGC-W UTG-UGGA-W UTG-UGGA-W
UTZ-KXGA
UTZ-VXGA
UTG-BGYA-W
-
-
-
-
-
-
- - - -
UTD-GXSA-W
Flange (Round)UTD-RF204
Flange (Square)
Long-Life Filter
UTD-SF045T
Long-Life Filter
For Compact Duct type
For High Static Pressure Duct type
Drain Pump Unit
UTD-LF60KA
UTZ-PX1BBA
For Low Static Pressure Duct type /Duct type
UTZ-PX1NBA
For Low Static Pressure Duct type / Duct type
For Low Static Pressure Duct type / Duct type
For Low Static Pressure Duct type / Duct type / Ceiling type
For Ceiling type
Drain Pump UnitUTR-DPB24T
New amenity space can be offered by installing the Remote sensor.
For All Duct type
Remote Sensor UnitUTD-RS100
Panel spacer
50mm
Indoor unit950
Panel 600
600 (mm)
For Cassette type
Panel Spacer
For Cassette type
Wide Panel UTG-AGYA-W
UTG-BGYA-W
UTD-LF25NA
Shuts the air outlet when only using as 3 blow out.
For Compact Cassette type
Air Outlet Shutter PlateUTR-YDZB
For Compact Cassette type
Grille KitUTG-UFYC-WUTG-UFGC-W
For Cassette type
Grille KitUTG-UGYA-WUTG-UGGA-W
UTR-EV09XB (for AS*E07/09LACH)UTR-EV14XB (for AS*E12/14LACH)
For Compact Wall Mounted type(EEV external type)
EV Kit
Shuts the air outlet when only using as 3 blow out.
For Cassette type
Air Outlet Shutter PlateUTR-YDZC
Insulation Kit
Insulation Kit for High HumidityUTZ-KXGAUTZ-KXGBUTZ-KXGC
For Cassette typeFor Slim Cassette typeFor Compact Cassette type
For Cassette type
Fresh Air Intake KitUTZ-VXGA
For Compact Cassette type
Fresh Air Intake KitUTZ-VXAA
Auto Louver Grille KitUTD-GXSA-W (for ARXD07/09/12/14LATH)UTD-GXSB-W (for ARXD18LATH)UTD-GXSC-W (for ARXD24LATH)For Slim Duct type
43
The colors may be different from the actual colors because this catalog is printed matter.Product specifications are subject to change without notice.
Distributed by :
“ ” is a worldwide trademark of FUJITSU GENERAL LIMITED and is a registered trademark in Japan, the U.S.A. and other countries or areas.*Echelon®, LONWORKS®, and the Echelon logo are trademarks of Echelon Corporation registered in the United States and other countries.*BACnet® is a registered trademark of the American Society of Heating Refrigeration and Air Conditioning Engineers (ASHRAE).
6NNJ22-1201E
1116, Suenaga, Takatsu-ku, Kawasaki 213-8502, Japanhttp://www.fujitsu-general.com/
Copyright© 2011 Fujitsu General Limited. All rights reserved.
Fujitsu General (Thailand) Co., Ltd.
ISO 9001Certified number : 01 100 89394
ISO 14001Certified number : 01 104 9245101
Fujitsu General (Shanghai) Co., Ltd.
ISO 9001Certified number : 01 100 79269
ISO 14001Certified number : 272043
Fujitsu General Central Air-conditioner (Wuxi) Co., Ltd.
ISO 9001Certified number : 00608Q11061R2M
ISO 14001Certified number : 00609E20454R2M