Meeting Various Needs with the FUJITSU GENERAL VRF AIRSTAGE Series

Upload: others

Post on 27-Apr-2020

3 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: Meeting Various Needs with the FUJITSU GENERAL VRF ...winfinity.com.sg/wp-content/uploads/2016/07/Airstage-J-II.pdf · Meeting Various Needs with the FUJITSU GENERAL VRF AIRSTAGE

Meeting Various Needs with

the FUJITSU GENERAL VRF AIRSTAGE Series

Page 2: Meeting Various Needs with the FUJITSU GENERAL VRF ...winfinity.com.sg/wp-content/uploads/2016/07/Airstage-J-II.pdf · Meeting Various Needs with the FUJITSU GENERAL VRF AIRSTAGE

INDOOR UNITS

Compact Cassette

HighStatic Pressure Duct

Cassette

Floor / Ceiling

Compact Duct

Ceiling

Slim Duct(Drain Pump internal)

Compact Wall Mounted(EEV internal / EEV external)

Low Static Pressure Duct /Duct

Wall Mounted

02

The AIRSTAGE J-II Series adopts the best technology and was designed with the greatest care to provide not only energy savings and comfort but also ease of design, installation, and maintenance. Fujitsu General provides air conditioning systems for a wide range of applications from small office buildings and stores to large houses.

Building owners End usersInstallers Service and Management companies

Various Line-up for each buildings

OUTDOOR UNITS

4HP5HP6HP

AJ*A36LALH

AJ*A45LALH

AJ*A54LALH

AJ* : AJY (FUJITSU), AJH (GENERAL)

Wide lineup of indoor units and controllers to support a variety of properties.

Page 3: Meeting Various Needs with the FUJITSU GENERAL VRF ...winfinity.com.sg/wp-content/uploads/2016/07/Airstage-J-II.pdf · Meeting Various Needs with the FUJITSU GENERAL VRF AIRSTAGE

CONTROLLERS

CentralRemote Controller

GroupRemote Controller

Touch PanelController

System Controller (Software)

WiredRemote Controller

SimpleRemote Controller

WirelessRemote Controller

03

Large Homes

Central Controller Individual Controller

Small Office

Page 4: Meeting Various Needs with the FUJITSU GENERAL VRF ...winfinity.com.sg/wp-content/uploads/2016/07/Airstage-J-II.pdf · Meeting Various Needs with the FUJITSU GENERAL VRF AIRSTAGE

The building load is the range of almost 40 % to 80%. Therefore, most air conditioners do not operate at maximum load, but operate at low to medium loads. Especially, for multi system, operation performance at partial load is important because all the air conditioners do not always operate all the time. Aiming at energy saving performance matched to actual operation, Fujitsu General has developed a high intermediate performance air conditioner corresponding not only to the rated performance at 100% load, but also to low to medium load

04

High EER / COP

High part load performance (6HP class)

FEATURES

Efficiency in actual operation

Load curve (a typical office building)

4 HP 5 HP

Conditions : Connected indoor units: AUXA30LALH+AUXD24LALHCooling : indoor temp. of 27°CDB / 19°CWB, outdoor temp. of 35°CDB / 24°CWBHeating : indoor temp. of 20°CDB / 15°CWB, outdoor temp. of 7°CDB / 6°CWB

6 HP

4.534.00 4.20

3.603.95

3.45

5.75

COPHeating part load

EERCooling part load

5.73

100%3.95

50%

100%3.45

50%

: COP: EER

66 %UP

46 %UP

00

20

40

60

80

100

3 6 9 12Time (h)

15 18 21 24

Bui

ldin

g lo

ad (%

)

Page 5: Meeting Various Needs with the FUJITSU GENERAL VRF ...winfinity.com.sg/wp-content/uploads/2016/07/Airstage-J-II.pdf · Meeting Various Needs with the FUJITSU GENERAL VRF AIRSTAGE

05

Com

pres

sor

effic

ienc

y

High

HighCompressor capacity

DC Twin Rotary compressor

Highly accurate parts

Optimized refrigerant flow design

High efficiency compressor motorDC twin rotary compressorEfficiency in all load regions is good. Especially good performance from low to medium at normal operation.

Large propeller fanHigh performance and low noise realized by large propeller and optimization of angle.

DC inverter controlEfficiency is improved by mounting of new active filter module.

Subcool heat exchangerCooling performance is improved by mounting of dual tube heat exchanger.

DC fan motorMiniaturized, low noise, high efficiency, multi-stage DC fan motor is mounted.

Large heat exchangerHeat exchange performance is substantially improved by mounting of 3-row large heat exchanger.

Pre

ssur

e

Enthalpy

effect

Cooling performance improved

Page 6: Meeting Various Needs with the FUJITSU GENERAL VRF ...winfinity.com.sg/wp-content/uploads/2016/07/Airstage-J-II.pdf · Meeting Various Needs with the FUJITSU GENERAL VRF AIRSTAGE

Auto Off functionThis prevents waste of energy.

Heating Cooling

OriginalSet Temp.

Set point limitation setting

Central Remote Controller

30

28

26

24

22

20

18

16

14

12

10

Cooling Set Temperature

Economy operationControl Temperature

Heating Set Temperature

Economy operationControl Temperature

Set Temp.

MAX. -4°C

MAX. +2°C

Economy operation

UpUp

Economy operation

Set Temp.

DownDown

DownDown

Capacity

Time

Settinglevel

18:00 20:00 22:00

OFF OFF OFF

Wasteful Operation is Prevented.

Operation Performance is Efficiently Controlled.Room temperature set point limitationThe minimum and maximum temperature range can be set.

Economy operationThe temperature setting is offset automatically over a certain period of time.

Capacity save operation The power consumption at peak is cut down.

Capacity saveSettingrange

80%

60%

40%

0%

06

FEATURES

(°C)

Page 7: Meeting Various Needs with the FUJITSU GENERAL VRF ...winfinity.com.sg/wp-content/uploads/2016/07/Airstage-J-II.pdf · Meeting Various Needs with the FUJITSU GENERAL VRF AIRSTAGE

Current model

Function setting is required. 1 indoor unit (Master) can apply this function.

ON

OFF

Operation stopped at oil recovery Time

Time

ONJ-II seriesSet Temp.

Temp.(°C)

Noiselevel

Time

(4~6HP)

Low Noise Design

Various Comfort Control Function

Heating capacity is improved at low outdoor temperature by our advanced technology.

Low noise design of outdoor unitSignificantly reduced noise by optimized airflow structure design of outdoor unit.

Powerful Heating

Low noise modeOutdoor unit can be switched to silent mode, depending on the installation environment.

Easy auto changeover functionAt the auto mode, cooling and heating mode is switched automatically to maintain the setting temperature.

Non-stop oil recovery operationThe product continues to operate without stopping the cooling or heating operation during oil recovery modes.

Auto louver grill (Option for Slim Duct)

Auto louver grille provides comfort and efficient heating with louver controlled ductable outlet

Rated noise value

-5dB ~ -6dB

56dB

53dB

Current model

J-II series

6HP class (Cooling)

Low noise mode

Heating operation

Heating operation

07

33%UP !

Cooling operation

7

Current model (6HP class)

16.6

Hea

ting

cap

acity

(kW

)

J-II series (6HP)

Outdoor temperature (°C)

Current model (6HP class)

-20 -10 0

With Auto Louver40

30

15

20

25

35

Tem

pera

ture

(°C

)

Page 8: Meeting Various Needs with the FUJITSU GENERAL VRF ...winfinity.com.sg/wp-content/uploads/2016/07/Airstage-J-II.pdf · Meeting Various Needs with the FUJITSU GENERAL VRF AIRSTAGE

FEATURES

Central Control of Small Office, Shop, etc.

08

Control system composition example

BACnet® Gateway(Software)

Network Convertorfor LONWORKS®

System Controller(Software)

Building controlcomputer

System Controller (Software)UTY-APGXMax. controllable 1,600 indoor units

Convertor forBMS Control

Building ManagementSystem

BACnet® Gateway(Software)UTY-ABGX

Network Convertorfor LONWORKS®

UTY-VLGX

NetworkConvertorUTY-VGGX

Security system

Ventilation system

Lighting facilities

A/C central controller

Group Remote ControllerUTY-CGG*Max. controllable18 indoor units

Central Remote ControllerUTY-DCG*Max. controllable100 indoor units

Touch Panel ControllerUTY-DTG*Max. controllable400 indoor units

G*: GY (FUJITSU), GG (GENERAL)

VRF network system

or

CentralRemote Controller

Touch Panel Controller

NetworkConvertor

Group Remote Controller

Page 9: Meeting Various Needs with the FUJITSU GENERAL VRF ...winfinity.com.sg/wp-content/uploads/2016/07/Airstage-J-II.pdf · Meeting Various Needs with the FUJITSU GENERAL VRF AIRSTAGE

Group Remote ControllerUTY-CGG*

• Max. controllable 18 indoor units

Individual and Central Control of Large Homes

09

Control system composition example

CentralRemote Controller

or

GroupRemote Controller

WirelessRemote Controller

WiredRemote Controller

+Wireless

Remote Controller

IR Receiver Unit+

Wireless Remote Controller

SimpleRemote Controller

WiredRemote Controller

+Simple

Remote Controller

WiredRemote Controller

Central Remote ControllerUTY-DCG*

or

• Automatic display of number of connected indoor unit

• Max. controllable 100 units

Simple Remote Controller

Wired Remote ControllerUTY-RNK*

With operation modeUTY-RSK*

Without operation modeUTY-RHK* K*: KY (FUJITSU), KYT (FUJITSU), KG (GENERAL)

H*: HY (FUJITSU), HG (GENERAL) G*: GY (FUJITSU), GG (GENERAL)

Wireless Remote ControllerUTY-LNH*

Page 10: Meeting Various Needs with the FUJITSU GENERAL VRF ...winfinity.com.sg/wp-content/uploads/2016/07/Airstage-J-II.pdf · Meeting Various Needs with the FUJITSU GENERAL VRF AIRSTAGE

Long Piping Length

High Capacity Connection

Our advanced refrigerant control technology allows us to achieve a total refrigerant piping length of 180 m. This opens up new possibilities in system design.

180 m max.

Height difference between indoor and indoor units

15 m max.

Piping length from first separation tube to the farthest indoor unit

40 m max.

Height difference between outdoor and indoor units

30 m max.

Actual piping length

120 m max.

Total piping length

CoolingCooling46°C

21°C

-5°C -5°C

-20°C -20°C

Heating

(°C)

-20°C areaOperation possiblein heating.

50

40

30

20

10

0

-10

-20

Number of connectable indoor unit

4 HP

5HP

6 HP

2 to 6 units

2 to 8 units

2 to 9 units

Wide operating rangeInstallation in extreme temperature conditions is possible due to an increase in operational range.Cooling : -5°C~46°CHeating : -20°C~21°C

10

FEATURES

12 types, 52 models

Indoor unit Connectable indoor unit capacity range

130 % max.

Page 11: Meeting Various Needs with the FUJITSU GENERAL VRF ...winfinity.com.sg/wp-content/uploads/2016/07/Airstage-J-II.pdf · Meeting Various Needs with the FUJITSU GENERAL VRF AIRSTAGE

3 7 1 0 2 4 5 6

Easier InstallationEasy piping connectionImprovement of the reliability by decreasing the flare connection.

Easy to connect with V-II communication system

It is possible to connect directly with the transmission cable of the V-II system without convertor.

J-II system V-II system

Connects without a converter

Easy wiring connection• Decreasing wiring mistakes by using non-polar 2 wires.(Remote controller cable is 3 wires)

• Improvement of wiring installation by common with V-II power supply method.

Flexible installation of outdoor unitCorresponds to the outdoor unit concentration installation.

Convenient Commissioning SupportAutomatic address setting functionThe address of each indoor unit can be automatically set by button switch of outdoor unit.

Connection check functionPossible to confirm whether wiring connection and address setting are correct by check run function for a short time.

Reduced installation intervals by front access

Flexible installation by 4 way pipe direction

11

Press the push buttonof outdoor unit.

• Display connected indoor unit numbers• Duplicately set address number of

indoor unit can be displayed

Flare connection

Terminal box

Flare connection

EV kit

J-II series Previous model

Power supply cablePower supply(Indoor )

Power supply(Outdoor )

Page 12: Meeting Various Needs with the FUJITSU GENERAL VRF ...winfinity.com.sg/wp-content/uploads/2016/07/Airstage-J-II.pdf · Meeting Various Needs with the FUJITSU GENERAL VRF AIRSTAGE

Emergencystop function

Emergency Stop Function

FEATURES

SU MO TU WE TH FR SA

Wired Remote Controller

Simple Remote Controller

Error status can be checked easily via the indoor unit wired controller An error code is displayed on a liquid crystal screen.

Faulty unit number (Remote controller address)Error code

Remote controller address

Error code

Design for Easy MaintenanceEasy to read 7-segment LEDConfirm detail operational and trouble status without using specific equipment

Movable PCB panelEasier for maintenance work behind the PCB

7-segment LED

Emergency alarm can be received by indoor, outdoor units, Central Remote Controller or Touch Panel Controller when they received it, all units will be stopped.

Touch Panel Controller

CentralRemote Controller

or

Emergencystop function

Emergencystop function

T h P l

Central

Note : In case of received Emergency alarm by Indoor / outdoor unit : All units connected within same refrigerant system will be stopped. Central Remote Controller or Touch Panel Controller : all units connected within VRF network system with Central Remote Controller or Touch Panel Controller will be stopped.

12

Equipment Detail (Diagram)

Trouble diagnosis by Service ToolConnection to Service Tool• Detail operation status and recent

error history can be checked and analyzed by using Service Tool.

• Last 5 min. operation memory can be also recorded.

Transmission cable(Non-polar 2 wires)

Service ToolUTY-ASGXUSB adaptor(Field supplied)

Software

Page 13: Meeting Various Needs with the FUJITSU GENERAL VRF ...winfinity.com.sg/wp-content/uploads/2016/07/Airstage-J-II.pdf · Meeting Various Needs with the FUJITSU GENERAL VRF AIRSTAGE

OUTDOOR UNITS

Specifications

Dimensions

AJ* : AJY (FUJITSU), AJH (GENERAL)

AJ* : AJY (FUJITSU), AJH (GENERAL)

AJ*A36LALH / AJ*A45LALH / AJ*A54LALH

Detail

650

970 32 12370

Terminal blocks (Transmission)

Terminal blocks (Power)

3-Way valve (Liquid)

3-Way valve (Gas)

Ø28

(Cab

le po

rt)

Ø28 (Cable port)

Pipe portPipe port

Pipe & cable port

Pipe port89

50438

622

65 15

1450

21 55 21 65

166

370

43(L

iquid)

51(G

as)

(410

)40

3213

34

907

297

(Gas

valve

)

279

5095 12

050 50

25

87131

(Liqu

id va

lve)

()

1000

111

70

155

14221

227

305

341

154

36

Ø28 (Cable port)Ø28 (Cable port)

Ø28 (Cable port)Ø28 (Cable port)

AA

(Unit : mm)

13

Capacity range HP

Model name

4 5 6

AJ*A36LALH AJ*A45LALH AJ*A54LALH

Power source

Capacity kW

kW

W / W

dB(A)

mm

Cooling

Cooling

Heating

Dimensions (H×W×D)

Heat exchanger fin

COP

EER

Input power

Sound pressure level

Connection pipe diameter

Weight

mm

kg

kg

11.2

12.5

14.0

16.0

1,334 x 970 x 370

Blue fin

117

Maximum connectable indoor unit 6 8 9

15.5

18.0

Heating 2.76 3.81 4.56

2.80 3.89 4.49

Cooling

Heating

Cooling

Heating

Air flow rate High m3/h

4.53 4.20 3.95

4.00 3.60 3.45

6,200 6,400 6,900

50 51 53

52 53 55

Refrigerant charge 4.8 5.3

9.52

15.88 19.05

Liquid

Gas

°CDBOperation rangeCooling

Heating

-5 to 46

-20 to 21

Note : Specifications are based on the following conditions.Cooling : Indoor temperature of 27°CDB / 19°CWB, and outdoor temperature of 35°CDB / 24°CWB.Heating : Indoor temperature of 20°CDB / (15°CWB), and outdoor temperature of 7°CDB / 6°CWB.Pipe length : 7.5 m; Height difference between outdoor unit and indoor unit : 0 m.The protective function might work when using it outside the operation range.

1Ø, ~ 230 V, 50 Hz

Page 14: Meeting Various Needs with the FUJITSU GENERAL VRF ...winfinity.com.sg/wp-content/uploads/2016/07/Airstage-J-II.pdf · Meeting Various Needs with the FUJITSU GENERAL VRF AIRSTAGE

INDOOR UNIT

14

* : Y(FUJITSU), H(GENERAL)

Compact Cassette

Cassette

Compact Duct

Slim Duct(Drain pump internal)

Low Static Pressure Duct

High Static Pressure Duct

Floor / Ceiling

Ceiling

Wall Mounted

Duct

Compact Wall Mounted(EEV internal)

Compact Wall Mounted(EEV external)

AUXB07LALH

ARXB07LALH

AS*E07LACH

AS*A07LACH

ARXD07LATH

AUXB09LALH

ARXB09LALH

AS*E09LACH

AS*A09LACH

ARXD09LATH

AUXB12LALH

ARXB12LALH

AS*E12LACH

AS*A12LACH

ARXD12LATH

AUXB14LALH

AS*E14LACH

ARXB14LALH

AS*A14LACH

ARXD14LATH

AB*A12LBTH AB*A14LBTH

12 Types, 52 Models, Capacity range from 2.2kW to 14.0kW

With this model, connection of EV kit is necessary

Indoor Unit Lineup

Capacity range (kW)

Model code

2.27

2.89

3.612

4.514

Page 15: Meeting Various Needs with the FUJITSU GENERAL VRF ...winfinity.com.sg/wp-content/uploads/2016/07/Airstage-J-II.pdf · Meeting Various Needs with the FUJITSU GENERAL VRF AIRSTAGE

15

Comprehensive range of indoor units of variety design and capacity ranges available which can be selected to suit any air conditioning needs.

AUXA54LALHAUXA36LALH

ARXB36LATH

ARXC36LATH

ARXA36LATH

AUXA45LALH

ARXC45LATH

ARXB45LATH

ARXA45LATH

AUXA30LALH

AB*A54LBTHAB*A36LBTH AB*A45LBTHAB*A30LBTH

ARXB30LATH

ARXA30LATH

AUXB18LALH

ARXB18LALH

AUXD18LALH

ARXD18LATH

AUXD24LALH

ARXB24LATH

ARXA24LATH

AS*A24LACHAS*A18LACH AS*A30LACH

AUXB24LALH

ARXD24LATH

AB*A18LBTH AB*A24LBTH

7.124

5.618

11.236

9.030

12.545

14.054

Page 16: Meeting Various Needs with the FUJITSU GENERAL VRF ...winfinity.com.sg/wp-content/uploads/2016/07/Airstage-J-II.pdf · Meeting Various Needs with the FUJITSU GENERAL VRF AIRSTAGE

Compact Cassette

Note : Specifications are based on the following conditions. Cooling : Indoor temperature of 27°CDB / 19°CWB, and outdoor temperature of 35°CDB / 24°CWB.Heating : Indoor temperature of 20°CDB / (15°CWB), and outdoor temperature of 7°CDB / 6°CWB.Pipe length : 7.5 m; Height difference between outdoor unit and indoor unit : 0 m.

INDOOR UNIT

Fast

Slow

Wind velocity

16

Air Outlet Shutter Plate:Fresh Air Intake Kit:Insulation Kit For High Humidity:

UTR-YDZBUTZ-VXAAUTZ-KXGC

SpecificationsModel No.

Power source

Air flow rate

Input power

Capacity

Sound pressure level

Dimensions (H x W x D)

Weight

Connection pipe diameter

Grille(option)

mm

kg

mm

kg

mm

V/ø/Hz

m3/h

W

kW

dB(A)

AUXB24LALH

7.1

8.0

84

1,030

830

450

50

44

30

AUXB18LALH

5.6

6.3

36

710

580

400

41

35

27

AUXB14LALH

4.5

5.0

35

680

590

390

38

34

27

AUXB12LALH

3.6

4.1

29

600

530

390

37

34

27

AUXB09LALH

2.8

3.2

25

550

450

350

35

30

25

AUXB07LALH

2.2

2.8

25

540

450

350

34

30

25

Model name

Dimensions (H x W x D)

Weight

High

High

Med

Cooling

Heating

Low

Med

Low

Liquid (Flare)

Gas (Frare)

Drain

AUXB07LALHAUXB09LALHAUXB12LALH

AUXB14LALHAUXB18LALHAUXB24LALH

Powerful wide air flow & Quiet operation

Grille is an option

1Ø, 230V ~, 50Hz

245 x 570 x 570

ø25 (I.D) ; ø32 (O.D.)

UTG-UFYC-W (FUJITSU brand); UTG-UFGC-W (GENERAL brand)

50 x 700 x 700

2.6

15

ø6.35

ø12.70

17

ø9.52

ø15.88

Optional parts

High efficiency 2-stage turbo fan

Adoption of laminar wing

Spin direction Airflow direction

Quiet

Airflow runs through smoothly along the laminar wing

No airflow separation

Laminar wingQuiet

Quiet quality

Designed by CFD-analysis (fluid) simulations

Optimization of wing form (laminar wing type) and wing number (7 blades each)

High lift drain pump

Ceiling panelHeight

700mm

Previous turbo fan2-stage turbo fan1-stage

+2-stage2 stage

In the case of a conventional fan, the air outlet range was narrow as the airflow moved to the motor side which meant the velocity of air passing through the heat exchanger was uneven.

Heat exchangeefficiency:

20%UP

A evenly spread air distribution across the heat exchanger is possible due to the new 2 stage turbo fan which produces two separate airflow streams.

Page 17: Meeting Various Needs with the FUJITSU GENERAL VRF ...winfinity.com.sg/wp-content/uploads/2016/07/Airstage-J-II.pdf · Meeting Various Needs with the FUJITSU GENERAL VRF AIRSTAGE

Cassette

IR Receiver Kit :Air Outlet Shutter Plate :Panel Spacer :Insulation Kit for High Humidity :Wide Panel :Fresh Air Intake Kit :H* : HY(FUJITSU), HG(GENERAL)

UTY-LRH*B1UTR-YDZCUTG-BGYA-WUTZ-KXGA / UTZ-KXGBUTG-AGYA-WUTZ-VXGA

High efficiency turbo fan with 3-dimensional blade

450mm

Heat exchanger< Motor side >

Uneven airflow

Separation phenomenon of airflow causes noise

: Spin direction : Airflow direction : Turbulent flow noise

< Motor side >Heat exchanger

3-dimensional blade

High efficiency airflow distribution has been achieved by the introduction of a 3 dimensional blade which increases the air passing over the heat exchanger.

Previous blade

500mm

No airflow separation

Quiet

Previous turbo fanAir passing through the heat exchanger was uneven and the air would only flow close to the ceiling.

Fast

Slow

Wind velocity

Improvement of the airflow distribution

The louvre design distributes air leaving a space between the chassis and the ceiling allowing far and wide air flow distribution.

Much less temperature irregularity happens by spreading airflow widely

Note : Specifications are based on the following conditions. Cooling : Indoor temperature of 27°CDB / 19°CWB, and outdoor temperature of 35°CDB / 24°CWB.Heating : Indoor temperature of 20°CDB / (15°CWB), and outdoor temperature of 7°CDB / 6°CWB.Pipe length : 7.5 m; Height difference between outdoor unit and indoor unit : 0 m.

Bottom viewFront part Ceiling

Rear part

Round louvre

17

Grille is an option

Powerful, wide airflow and quiet operation

AUXD18LALHAUXD24LALHAUXA30LALH

AUXA36LALHAUXA45LALHAUXA54LALH

SpecificationsModel No.

Power source

Air flow rate

Input power

Capacity

Sound pressure level

Dimensions (H x W x D)

Weight

Connection pipe diameter

Grille(option)

mm

kg

mm

kg

mm

V/ø/Hz

m3/h

W

kW

dB(A)

14.0

16.0

119

2,000

1,370

1,100

47

39

33

12.5

14.0

99

1,900

1,370

1,100

46

39

33

ø19.05

11.2

12.5

80

1,800

1,300

1,100

44

38

33

9.0

10.0

59

1,600

1,300

1,100

40

38

33

7.1

8.0

46

1,280

1,040

870

38

33

29

ø15.88

5.6

6.3

39

1,150

940

870

36

30

29

Model name

Dimensions (H x W x D)

Weight

High

High

Med

Cooling

Heating

Low

Med

Low

Liquid (Flare)

Gas (Frare)

Drain

1Ø, 230V ~, 50Hz

ø9.52

ø25 (I.D.) ; ø32 (O.D.)

UTG-UGYA-W (FUJITSU brand); UTG-UGGA-W (GENERAL brand)

50 x 950 x 950

5.5

246 x 840 x 840

23

288 x 840 x 840

27

Optional parts

AUXA54LALHAUXA45LALHAUXA30LALHAUXD24LALHAUXD18LALH AUXA36LALH

Page 18: Meeting Various Needs with the FUJITSU GENERAL VRF ...winfinity.com.sg/wp-content/uploads/2016/07/Airstage-J-II.pdf · Meeting Various Needs with the FUJITSU GENERAL VRF AIRSTAGE

INDOOR UNIT

Remote Sensor Unit :IR Receiver Unit :Drain Pump Unit :*WC : YWC, TWC

UTD-RS100UTB-*WCUTZ-PX1BBA

Optional parts

Note : Specifications are based on the following conditions.Cooling : Indoor temperature of 27°CDB / 19°CWB, and outdoor temperature of 35°CDB / 24°CWB.Heating : Indoor temperature of 20°CDB / (15°CWB), and outdoor temperature of 7°CDB / 6°CWB.Pipe length : 7.5 m; Height difference between outdoor unit and indoor unit : 0 m.

SpecificationsModel No.

Power source

Air flow rate

Input power

Capacity

Sound pressure level

Dimensions (H x W x D)

Weight

Static pressure range

Standard static pressure

Connection pipe diameter

mm

kg

mm

V/ø/Hz

m3/h

W

kW

dB(A)

Pa

5.6

6.3

96

890

810

730

0 to 50

25

36

34

30

ø9.52

ø15.88

4.5

5.0

90

800

750

700

0 to 50

25

33

32

30

217 x 953 x 595

25

2.8

3.2

55

440

370

340

0 to 50

25

31

29

27

217 x 663 x 595

18

ø6.35

ø12.70

2.2

2.8

46

370

310

280

0 to 50

25

29

26

24

High

High

Med

Cooling

Heating

Low

Med

Low

Liquid (Flare)

Gas (Frare)

Drain

1Ø, 230V ~, 50Hz

3.6

4.0

63

590

500

450

0 to 50

25

30

28

25

ø25 (I.D.) ; ø32 (O.D.)

Small and compact indoor unit suitable for many applications

Low noise level

7 9

0 to 50

27

Pa

dB(A)

Static pressurerange

Noise level(Low speed)

30

Model

24 25 30

12 14 18

A low noise level has been achieved for each capacity

Static pressure (Pa)

Low static pressuremode

Normal mode

Airflow drop prevention

Low noise realized

Airf

low

18

ARXB07LALHARXB09LALHARXB12LALH

ARXB14LALHARXB18LALH

Compact Duct

ARXB18LALHARXB14LALHARXB12LALHARXB09LALHARXB07LALH

Slim size (217mm) allows installation even where the space behind the ceiling is narrow.

Air-intake at back side makes it possible to reduce the noise effectively.

Compact design

Air-intake

Ultra-slim duct air conditioner for easy installation

Height217mm

Flexible installation

Floor concealedCeiling concealed

Bottom sideBack side

*1

*1: For the air-intake at bottom, the operation noise is larger than the value mentioned in the above table.

Page 19: Meeting Various Needs with the FUJITSU GENERAL VRF ...winfinity.com.sg/wp-content/uploads/2016/07/Airstage-J-II.pdf · Meeting Various Needs with the FUJITSU GENERAL VRF AIRSTAGE

Optional partsIR Receiver Unit:Remote Sensor Unit:Auto Louver Grille Kit

*WC : YWC, TWC

UTB-*WCUTD-RS100UTD-GXSA-W (for ARXD07/09/12/14LATH)UTD-GXSB-W (for ARXD18LATH)UTD-GXSC-W (for ARXD24LATH)

19

Slim Duct

•Slim design with drain pump •Increase static pressure range

ARXD07LATHARXD09LATHARXD12LATH

ARXD14LATHARXD18LATHARXD24LATH

Note : Specifications are based on the following conditions.Cooling : Indoor temperature of 27°CDB / 19°CWB, and outdoor temperature of 35°CDB / 24°CWB.Heating : Indoor temperature of 20°CDB / (15°CWB), and outdoor temperature of 7°CDB / 6°CWB.Pipe length : 7.5 m; Height difference between outdoor unit and indoor unit : 0 m.

SpecificationsModel No.

Power source

Air flow rate

Input power

Capacity

Sound pressure level

Dimensions (H x W x D)

Weight

Static pressure range

Standard static pressure

Connection pipe diameter

mm

kg

mm

V/ø/Hz

m3/h

W

kW

dB(A)

Pa

18

High

High

Med

Cooling

Heating

Low

Med

Low

Liquid (Flare)

Gas (Frare)

Drain

1Ø, 230V ~, 50Hz

19

ø25 (I.D.) ; ø32 (O.D.)

7.1

8.0

122

1,330

1,240

1,100

0 to 50

25

35

32

29

198 x 1,100 x 620

27

ARXD24LATH

4.5

5.0

92

800

710

610

0 to 90

25

34

32

28

ARXD14LATH

5.6

6.3

83

940

840

750

0 to 90

25

34

32

28

198 x 900 x 620

23

ARXD18LATH

3.6

4.0

54

600

510

450

0 to 90

25

30

27

24

ARXD12LATH

198 x 700 x 620

ø6.35

ø12.70

2.8

3.2

50

600

550

480

0 to 90

25

29

26

24

ARXD09LATH

2.2

2.8

44

550

490

440

0 to 90

25

28

25

22

ARXD07LATH

ø9.52

ø15.88

Auto Louver Grille Kit (Option)Slim design

Drain port

Height

Drain pump built-in

198mmDrain pump

This model is slim design, it can install at the place where a ceiling is narrow.

Simple flat Auto Louver will provide comfort airflow and harmonize with luxury interior.

Slim Duct

Wired RemoteController

Wireles RemoteController

Auto Louver Grille

Flexible installation

Floor concealedCeiling concealed

Selectable wide range static pressureBy using DC fan motor, it is possible to change the static pressure range 0 to 90Pa. The change of static pressure range is possible by remote controller.

Static pressurerange

0 to 90 Pa24 model is 0 to 50Pa 0

400 500 600 700 800

60

120

Air Flow [m3/h]

(ARXD12LATH)Available air flow rate range @ Hi speed

11 steps

Ext

erna

l Sta

tic P

ress

ure[

Pa]

Air-intakeAir intake direction can be selected to match the installation site.

Depending on the installation site, air-intake at back side makesit possible to reduce the noise effectively.

Bottom sideBack side

Normal

*1

*1: For the air-intake at bottom, the operation noise is larger than the value mentioned in the above table.

Page 20: Meeting Various Needs with the FUJITSU GENERAL VRF ...winfinity.com.sg/wp-content/uploads/2016/07/Airstage-J-II.pdf · Meeting Various Needs with the FUJITSU GENERAL VRF AIRSTAGE

20

Optional partsRemote Sensor Unit :Long-Life Filter : Flange (Square) :*WC : YWC, TWC

UTD-RS100 UTD-LF25NA UTD-SF045T

Flange (Round) :IR Receiver Unit :Drain Pump Unit :

UTD-RF204 UTB-*WCUTZ-PX1NBA

INDOOR UNIT

ARXB24LATHARXB30LATHARXB36LATHARXB45LATH

ARXA24LATHARXA30LATHARXA36LATHARXA45LATH

Low Static Pressure Duct Duct

Low Static Pressure Duct/Duct

Note : Specifications are based on the following conditions. Cooling : Indoor temperature of 27°CDB / 19°CWB, and outdoor temperature of 35°CDB / 24°CWB.Heating : Indoor temperature of 20°CDB / (15°CWB), and outdoor temperature of 7°CDB / 6°CWB.Pipe length : 7.5 m; Height difference between outdoor unit and indoor unit : 0 m.

SpecificationsModel No.

Power source

Air flow rate

Input power

Capacity

Sound pressure level

Dimensions (H x W x D)

Weight

Static pressure range

Standard static pressure

Connection pipe diameter

mm

kg

mm

V/ø/Hz

m3/h

W

kW

dB(A)

Pa

1Ø, 230V ~, 50Hz

270 x 1,135 x 700

ø9.52

ø25 (I.D.) ; ø32 (O.D.)

ø15.88 ø19.05ø15.88 ø19.05

High

High

Med

Cooling

Heating

Low

Med

Low

Liquid (Flare)

Gas (Frare)

Drain

12.5

14.0

312

1,720

1,670

1,600

30 to 150

100

43

41

39

ARXA45LATH

11.2

12.5

312

1,720

1,670

1,600

30 to 150

100

43

41

39

45

ARXA36LATH

9.0

10.0

188

1,280

1,210

1,130

30 to 150

100

40

38

36

ARXA30LATH

7.1

8.0

190

1,280

1,210

1,130

30 to 150

100

38

36

34

43

ARXA24LATH

12.5

14.0

338

1,970

1,790

1,670

0 to 80

60

41

38

36

ARXB45LATH

11.2

12.5

253

1,710

1,600

1,470

0 to 80

50

37

35

33

45

ARXB36LATH

9.0

10.0

198

1,410

1,280

1,150

0 to 80

50

34

32

29

ARXB30LATH

1Ø, 230V ~, 50Hz

270 x 1,135 x 700

ø9.52

ø25 (I.D.) ; ø32 (O.D.)

7.1

8.0

145

1,100

920

810

0 to 80

40

31

27

25

43

ARXB24LATH

Optimum model for hotels or bedrooms

Line-up of low-noise and high-power models, compatible with a wide range of static pressure

Static pressure 0

Airf

low

Low Static Pressure Duct type

Low Static Pressure Duct type

Duct type

ARXB30Low

29dB

Max.150Pa

An ultra low-noise model that achieves a quiet interior. Perfect for hotels or bedrooms with limited air duct installation space. Two different levels can be selected according to the static pressure range.

Powerful model with a flexible design

Duct type

With a powerful motor, appropriate for a wide range of static pressure. Flexible air duct installation is possible in a large space such as an office.

Easy maintenance

1.Control box2.Fan casing3.Fan4.Motor

Previous model

2

4

13

Large bottom panel: 1 piece

New model1

4

32

Bottom panel: 2 pieces

Two-direction drain piping

Two-direction drain pipingDuct indoor unit

See below for the case of rear suction type

Page 21: Meeting Various Needs with the FUJITSU GENERAL VRF ...winfinity.com.sg/wp-content/uploads/2016/07/Airstage-J-II.pdf · Meeting Various Needs with the FUJITSU GENERAL VRF AIRSTAGE

21

Optional partsLong-Life Filter :IR Receiver Unit :Remote Sensor Unit :*WC : YWC, TWC

UTD-LF60KAUTB-*WCUTD-RS100

High Static Pressure Duct

These indoor units allow for high airflow quantities

ARXC36LATHARXC45LATH

Note : Specifications are based on the following conditions. Cooling : Indoor temperature of 27°CDB / 19°CWB, and outdoor temperature of 35°CDB / 24°CWB.Heating : Indoor temperature of 20°CDB / (15°CWB), and outdoor temperature of 7°CDB / 6°CWB.Pipe length : 7.5 m; Height difference between outdoor unit and indoor unit : 0 m.

SpecificationsModel No.

Power source

Air flow rate

Input power

Capacity

Sound pressure level

Dimensions (H x W x D)

Weight

Static pressure range

Standard static pressure

Connection pipe diameter

mm

kg

mm

V/ø/Hz

m3/h

W

kW

dB(A)

Pa

12.5

14.0

427

3,500

3,000

2,460

100 to 250

100

49

45

42

47

1Ø, 230V ~, 50Hz

400 x 1,050 x 500

ø9.52 (Flare)

ø19.05 (Flare)

ø25 (I.D.) ; ø32 (O.D.)

11.2

12.5

405

2,600

1,950

1,450

100 to 200

100

45

38

32

45

High

High

Med

Cooling

Heating

Low

Med

Low

Liquid (Flare)

Gas (Frare)

Drain

ARXC45LATHARXC36LATH

Low noise design Easy installation (Compact size & Lightweight)A compact size and lightweight indoor unit has been developed by reducing the basic chassis and the overall material weight.

Volume

47.5%down

Weight

40%down

Previous model : 75kg

400

8001,250(unit: mm)

400

5001,050

ARXC36L : 45kg

Cutting off the corners of the conventional indoor unit front panel and fan casing, has enabled less turbulent air flow. Low noise is realized by adopting a plastic case and a plastic fan.

Previous modelNew model (ARXC36L)

Heat exchanger

Plastic fan

Casing (Plastic)

500mm

400m

m

ø225mm

New model:Plastic fan [45dB(A)]

400m

m

Heat exchanger

800mm

Previous model:Metal fan [53.1dB(A)]

Metal fanø240mm

Casing (Metal Sheet)

ARXC36L

45dB(A) (At 100Pa : Actual noise measurement value)

Page 22: Meeting Various Needs with the FUJITSU GENERAL VRF ...winfinity.com.sg/wp-content/uploads/2016/07/Airstage-J-II.pdf · Meeting Various Needs with the FUJITSU GENERAL VRF AIRSTAGE

22

Flexible installation Easy maintenance

INDOOR UNIT

AB*A12LBTHAB*A14LBTHAB*A18LBTHAB*A24LBTH

Floor / Ceiling Type

AB* : ABY(FUJITSU), ABH(GENERAL)Note : Specifications are based on the following conditions.

Cooling : Indoor temperature of 27˚CDB / 19˚CWB, and outdoor temperature of 35˚CDB / 24˚CWB.Heating : Indoor temperature of 20˚CDB / (15˚CWB), and outdoor temperature of 7˚CDB / 6˚CWB.Pipe length : 7.5 m; Height difference between outdoor unit and indoor unit : 0 m.Voltage : 230 [V].

SpecificationsModel No.

Power source

Air flow rate

Input power

Capacity

Sound pressure level

Dimensions (H x W x D)

Weight

Connection pipe diameter

mm

kg

mm

V/ø/Hz

m3/h

W

kW

dB(A)

1Ø, 230V ~, 50Hz

199 x 990 x 655

ø25 (I.D.) ; ø32 (O.D.)

ø6.35

ø12.70

ø9.52

ø15.88

High

High

Med

Cooling

Heating

Low

Med

Low

Liquid (Flare)

Gas (Frare)

Drain

7.1

8.0

99

1,000

820

680

47

42

37

AB*A24LBTH

5.6

6.3

74

1,000

720

580

46

39

35

27

AB*A18LBTH

4.5

5.0

42

780

640

550

40

36

34

AB*A14LBTH

3.6

4.0

30

660

570

490

36

32

28

25

AB*A12LBTH

Example for ceiling installation Floor console Under ceilingExample for floor installation

A combination of up/down and right/left directional swing allows three-dimensional air direction control.

Double auto swing

4

4

5

3

3

2

2 1

1

UP and DOWN SWINGRIGHT and LEFT SWING

5 steps selectable

4 steps selectable

• High power• Wide rotation range• High efficiency

High power DC fan motor

(Unit : mm)990 199

655

Symmetrical, slim and compact design.

Compact design

The slim and lightweight design allow the unit to be suspendedfrom the ceiling or installed on the floor. This type suits many room designs

Page 23: Meeting Various Needs with the FUJITSU GENERAL VRF ...winfinity.com.sg/wp-content/uploads/2016/07/Airstage-J-II.pdf · Meeting Various Needs with the FUJITSU GENERAL VRF AIRSTAGE

23

Optional partsDrain Pump Unit :Flange :

UTR-DPB24TUTD-RF204

Ceiling Type

AB*A30LBTHAB*A36LBTHAB*A45LBTHAB*A54LBTH

AB* : ABY(FUJITSU), ABH(GENERAL)Note : Specifications are based on the following conditions.

Cooling : Indoor temperature of 27˚CDB / 19˚CWB, and outdoor temperature of 35˚CDB / 24˚CWB.Heating : Indoor temperature of 20˚CDB / (15˚CWB), and outdoor temperature of 7˚CDB / 6˚CWB.Pipe length : 7.5 m; Height difference between outdoor unit and indoor unit : 0 m.Voltage : 230 [V].

SpecificationsModel No.

Power source

Air flow rate

Input power

Capacity

Sound pressure level

Dimensions (H x W x D)

Weight

Connection pipe diameter

mm

kg

mm

V/ø/Hz

m3/h

W

kW

dB(A)

1Ø, 230V ~, 50Hz

240 x 1,660 x 700

ø9.52

ø25 (I.D.) ; ø32 (O.D.)

High

High

Med

Cooling

Heating

Low

Med

Low

Liquid (Flare)

Gas (Frare)

Drain

14.0

16.0

180

2,270

1,780

1,280

51

45

36

AB*A54LBTH

12.5

14.0

131

2,010

1,600

1,230

48

42

35

48

ø19.05

AB*A45LBTH

11.2

12.5

85

1,690

1,400

1,170

45

38

34

AB*A36LBTH

9.0

10.0

66

1,630

1,370

1,140

42

38

33

47

ø15.88

AB*A30LBTH

General installation pattern which suspends the indoor unit from the ceiling.

InstallationOpen

Installation pattern where part of the indoor unit is embedded into the ceiling.

Concealed

Installation which fixes the indoor unit to the wall by the use of wall brackets (Field supplied). This type of installation can be used when the ceiling space is insufficient.

(Field Supplied)

Wall mounted

Auto airflow direction and auto swing

Double auto swing and wide airflow

4

3

2

1

4 steps selectable

5 steps selectable

Up and down

Right and left

Optional drain lift-up mechanism allows flexible installation.

Fresh air intake

Condensate lift-up mechanism (Option)

Indoor

Max.500mm

Easily concealed in any installation

Page 24: Meeting Various Needs with the FUJITSU GENERAL VRF ...winfinity.com.sg/wp-content/uploads/2016/07/Airstage-J-II.pdf · Meeting Various Needs with the FUJITSU GENERAL VRF AIRSTAGE

275mm

215mm

New model

790mm

Compact design Air conditioner filter features

More Comfort & Convenience

Long-life* ion deodorization filter

Apple-catechin filter

The filter deodorizes by powerfully decomposing absorbed odors using the oxidizing and reducing effects of ions generated by the ultra-fine-particle ceramic.*The filter can be used for approx. 3 years if it is washed under water to restore its surface action when it is dirty.

Fine dust, invisible mold spores, and harmful microorganisms are absorbed onto the filter by static electricity, and further growth is inhibited and deactivated by the polyphenol ingredient extracted from apples.

Easy maintenance

Removable & washable panel• Powerful cooling & heating by using DC fan motor • Auto-restart function memorizes the operating mode as before,

once the power supply is restored.• Comfortable timer (ON, OFF, PROGRAM, SLEEP)

24

Compact Wall Mounted Type

Simple design with energy saving.

INDOOR UNIT

AS*A07LACHAS*A09LACHAS*A12LACHAS*A14LACH

AS*E07LACHAS*E09LACHAS*E12LACHAS*E14LACH

EEV internal EEV external

AS* : ASY(FUJITSU), ASH(GENERAL)Note : Specifications are based on the following conditions.

Cooling : Indoor temperature of 27°CDB / 19°CWB, and outdoor temperature of 35°CDB / 24°CWB.Heating : Indoor temperature of 20°CDB / (15°CWB), and outdoor temperature of 7°CDB / 6°CWB.Pipe length : 7.5 m; Height difference between outdoor unit and indoor unit : 0 m.Voltage : 230 [V].

SpecificationsModel No.

Power source

Air flow rate

Input power

Capacity

Sound pressure level

Dimensions (H x W x D)

Weight

EV Kit (option)

Connection pipe diameter

mm

kg

mm

V/ø/Hz

m3/h

W

kW

dB(A)

2.2

2.8

15

490

450

370

34

32

26

3.6

4.1

20

560

480

420

38

34

30

4.5

5.0

28

680

490

420

43

35

30

2.8

3.2

16

500

450

370

35

32

26

UTR-EV09XB UTR-EV14XB

2.2

2.8

16

490

450

370

35

33

27

2.8

3.2

16

500

450

370

36

33

27

3.6

4.1

19

560

480

420

39

35

31

4.5

5.0

30

670

490

420

44

37

32

1Ø, 230V ~, 50Hz

275 x 790 x 215

9

ø6.35

ø12.70

ø13.8(I.D.) ; ø15.8-ø16.7(O.D.)

-

1Ø, 230V ~, 50Hz

275 x 790 x 215

9

ø6.35

ø12.70

ø13.8(I.D.) ; ø15.8-ø16.7(O.D.)

High

High

Med

Cooling

Heating

Low

Med

Low

Liquid (Flare)

Gas (Frare)

Drain

AS*E14LACHAS*E12LACHAS*E09LACHAS*E07LACHAS*A14LACHAS*A12LACHAS*A09LACHAS*A07LACH

Page 25: Meeting Various Needs with the FUJITSU GENERAL VRF ...winfinity.com.sg/wp-content/uploads/2016/07/Airstage-J-II.pdf · Meeting Various Needs with the FUJITSU GENERAL VRF AIRSTAGE

Ion Deodorization Filter

Apple-catechin Filter

Pre Filter

Organic coating fin used heat exchanger

Antibacterial deodorizing pre-filter with special ceramic powder

Long-life* Ion Deodorization Filter

Apple-catechin Filter

Using different filters at both sides

The filter deodorizes by powerfully decomposing absorbed odors using the oxidizing and reducing effects of ions generated by the ultra-fine-particle ceramic.

Fine dust, invisible mold spores, and harmful microorganisms are absorbed onto the filter by static electricity, and further growth is inhibited and deactivated by the polyphenol ingredient extracted from apples.

(*The filter can be used for approx. 3 years if it is washed under water to restore its surface action when it is dirty.)

25

“Vertical airflow” provides powerful floor level heating

Air conditioner filter features

Wall Mounted Type

Simple & Elegant Appearance Design

AS*A18LACHAS*A24LACHAS*A30LACH

AS* : ASY(FUJITSU), ASH(GENERAL)Note : Specifications are based on the following conditions.

Cooling : Indoor temperature of 27˚CDB / 19˚CWB, and outdoor temperature of 35˚CDB / 24˚CWB.Heating : Indoor temperature of 20˚CDB / (15˚CWB), and outdoor temperature of 7˚CDB / 6˚CWB.Pipe length : 7.5 m; Height difference between outdoor unit and indoor unit : 0 m.Voltage : 230 [V].

SpecificationsModel No.

Power source

Air flow rate

Input power

Capacity

Sound pressure level

Dimensions (H x W x D)

Weight

Connectionpipe diameter

mm

kg

mm

V/ø/Hz

m3/h

W

kW

dB(A)

High

High

Med

Cooling

Heating

Low

Med

Low

Liquid (Flare)

Gas (Frare)

Drain

8.0

9.0

91

1,240

980

770

52

45

35

AS*A30LACH

1Ø, 230V ~, 50Hz

7.1

8.0

64

1,100

910

730

48

43

35

320 x 998 x 228

15

ø9.52

ø15.88

ø12 (I.D.) ; ø16 (O.D.)

AS*A24LACH

5.6

6.3

35

840

770

690

41

39

35

AS*A18LACH

Easy maintenance

“Horizontal airflow” does not blow cool air directly at the occupants in the room

Power diffuser

Power diffuser (full open)

46o

(24/30)

(24/30)

Simplification of drain pan cleaning improves maintenance-ability.

33 32 31 30 29

(˚C)

(24/30)

Vertical airflow

Outside air conditions: 2°C 60%Operation contents: HeatingSet temperature (Max set temp) 30°C, Air flow HiVertical flap: DownwardHorizontal flap: Center

00 3 6 9 12(m)

1

2.1(m)

(˚C)

15 16 17 18

(24/30)

Horizontal airflow

Outside air conditions: 35°C 40%Operation contents: CoolingSet temperature (Min set temp) 18°C, Air flow HiVertical flap: UpwardHorizontal flap: Center

00 3 6 9 12(m)

1

2.1(m)

Page 26: Meeting Various Needs with the FUJITSU GENERAL VRF ...winfinity.com.sg/wp-content/uploads/2016/07/Airstage-J-II.pdf · Meeting Various Needs with the FUJITSU GENERAL VRF AIRSTAGE

26

CONTROLLER

SystemAir ConditioningCentral Control

Air ConditioningIndividual Control

Outdoor unit

Indoor unit

Signal AmplifierUTY-VSGX

General-purpose Building Control Computer

BuildingManagement

Service Tool (Software)UTY-ASGX

USBAdaptor

NetworkConvertor

UTY-VGGX

Card-key

(Field supplied)

(Field supplied)

For single split

Connectable tovarious sized BMS/BAS

NetworkConvertorUTY-VGGX

Web Monitoring Tool (Software)UTY-AMGX

(VRF system side)

Internet orPublic Telephone Line

(Monitoring side)

or

IR Receiver UnitUTB-YWC

Remote/Monitoring side

Internet or PublicTelephone Line

IR Receiver KitUTY-LRH*B1

Wired Remote ControllerUTY-RNK*

External Switch ControllerUTY-TEKX

Network Convertor(BMS / LONWORKS®)UTY-VLGX

System Controller (Software)UTY-APGX

Simple Remote ControllerUTY-RSK*

Simple Remote ControllerUTY-RHK*Without master control

Wireless Remote ControllerUTY-LNH*

The V-II system supports every users needs by offering a variety of Control systems,including individual control, central control and building management control options.

System diagram

*2USB

Adaptor

(Field supplied)

*2

USBAdaptor

(Field supplied)

*2

*1

USBAdaptor

(Field supplied)

*2

BACnet ® Gateway (Software)UTY-ABGX

Group Remote ControllerUTY-CGG*

Touch Panel ControllerUTY-DTG*

*1. BMS/BAS: Building Management System / Building Automation System*2. USB Adaptor is U10 USB Network Interface of Echelon® Corporation.

Transmission line (VRF Network)Remote controller lineUSB cable

LONWORKS® NetworkEthernetSignal line(Single split system)

The devices above cannot be connected to the S series. (Except System Controller & BACnet® Gateway)

Central Remote ControllerUTY-DCG*

Control Systems

* : Y(FUJITSU), G(GENERAL)

Group Remote Controller line

Page 27: Meeting Various Needs with the FUJITSU GENERAL VRF ...winfinity.com.sg/wp-content/uploads/2016/07/Airstage-J-II.pdf · Meeting Various Needs with the FUJITSU GENERAL VRF AIRSTAGE

27

Max. controllable remote controller groups

Max. controllable indoor units

Max. controllable groups

On / Off

Operation mode setting

Fan speed setting

Room temp. setting

Room temp. set point limitation

Test operation

Up/down air direction flap setting

Right/left air direction flap setting

Group setting

RC prohibition

Anti freeze setting

Economy mode setting

Failure

Defrosting

Current time

Day of week

R.C. prohibition

Cooling/heating priority

Address display

Schedule timer

On/off timer

Sleep timer

Program timer

Day off

Min. unit of timer setting (Minutes)

Status monitoring system

Electricity charge calculation

Error history

Emergency stop

Control via internet

E-mail notification for malfunction

Item

Model name

Air

cond

ition

ing

cont

rol f

unct

ion

Dis

play

Tim

erC

ontr

ol

Period

On/off per day

On/off per week

Central RemoteController

100

100

16

-

-

-

-

-

-

-

-

-

-

Week

20

140

-

-

-

2

10

-

-

-

-

-

-

UTY-DCG*

Touch PanelController

400

400

400

Year

20

140

-

-

-

10

-

-

-

UTY-DTG*

*3

Comparison table of Controllers

K*:KY(FUJITSU), KYT(FUJITSU), KG(GENERAL), H*: HY(FUJITSU), HG(GENERAL), G*: GY(FUJITSU), GG(GENERAL)*1 "Operation mode" setting is not available for this model.*2 In the case of connection constitution for only J-II.*3 This function is available only through external input. control.

System Controller

1600

1600

1600

-

Year

72

504

-

-

-

10

-

UTY-APGX

Software

*3

Group RemoteController

8

18

-

-

-

-

-

-

-

-

-

-

-

Week

4

28

-

-

-

-

10

-

-

-

-

-

-

UTY-CGG*

*2

Wireless RemoteController

1

9

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

5

-

-

-

-

-

-

UTY-LNH*

*2

*1Simple RemoteController

1

9

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

UTY-RHK*

*2

Simple RemoteController

1

9

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

UTY-RSK*

*2

Wired RemoteController

1

9

-

-

-

-

-

Week

4

28

-

-

30

-

-

-

-

-

UTY-RHK*

*2

Page 28: Meeting Various Needs with the FUJITSU GENERAL VRF ...winfinity.com.sg/wp-content/uploads/2016/07/Airstage-J-II.pdf · Meeting Various Needs with the FUJITSU GENERAL VRF AIRSTAGE

CONTROLLER

28

The room temperature can be controlled by detecting the temperature accurately from the built-in sensor•Simple operation with Built-in Weekly / Daily Timer.•Control up to 9 indoor units.•Up to 2 wired remote controllers can be connected to a single indoor unit.

•A large On / Off button is provided in the centre of the remote controller for easy operation.

•Background light enables easy operation in a darkened room.

•Following an error display, diagnostics can be carried out on the controller.

User-friendly operation

Built-in timers

Wired Remote Controller

Simple Remote Controller

Compact remote controller provides access to basic functions

UTY-RSK*UTY-RHK* (Without ability to change operation mode)

•Up to 9 indoor units can be controlled with one remote controller.•Suitable for hotels or offices as it is easily operated with no complex functions.

Weekly timer: Possible to set ON/OFF time to operate twice each day of the week.Setback timer: Possible to set temperature for two times spans and for each day of the week.At "Weekly timer" + "Set back timer" setup

Indoor temperature can be detected accurately by the inclusion of a thermo sensor in the body of the wired controller. This new wired remote controller and the optional remote sensor allows flexibility in sensor location, suitable for all requirements.

Accurate and comfortable

Example of changing sensorRemote Sensor in the bedroom

Wired Remote Controller in the living room

Wired remotecontroller

Indoor unit

Remotesensor

The detecting point can be easily changed

Day Night

Displayed temperature is set temperature.

Max. controllable

9indoor units

Max. controllable

9indoor units

Functions

*1: "Operation mode" setting is not available. It is recommend to use together with other type controller.

Two methods are available for determining the cause of failure in the event of a malfunction occurs:

Diagnosis check function

Simple installationComponents are compatible with standard switch boxes. Flat back surface allows to be installed wherever it is needed.

Model

On / Off

Fan control

Operation mode

Room temp. setting

UTY-RSK* UTY-RHK*

*1

UTY-RNK*

Model No.

SpecificationsUTY-RNK*

DC 12V

120 x 120 x 18

160

UTY-RSK*

DC 12V

120 x 75 x 14

90 (100 : UTY-RSKYT)

UTY-RHK*

DC 12V

120 x 75 x 14

90 (100 : UTY-RHKYT)

Power Source

Dimensions (H x W x D) (mm)

Weight (g)

DC12V is supplied by the indoor unit.K*: KY(FUJITSU), KYT(FUJITSU), KG(GENERAL)

UTY-RSK* UTY-RHK*Without ability to

change operation mode

Page 29: Meeting Various Needs with the FUJITSU GENERAL VRF ...winfinity.com.sg/wp-content/uploads/2016/07/Airstage-J-II.pdf · Meeting Various Needs with the FUJITSU GENERAL VRF AIRSTAGE

29

UTY-LNH*

•A single controller controls up to 9 indoor units.

Max. controllable

9indoor units

Selectable

4daily timers

Simple and sophisticated operations with a choice of 4 daily timers

UTY-LNH*

Wireless Remote Controller

Model No. UTY-LNH*

1.5V (R03 / LR03 / AAA) x 2

158 x 56 x 20

70

UTB-*WC

DC 12V

122 x 60 x 26.5

150

UTY-LRH*B1

DC 12V

213.8 x 213.8x 25.7

140

Battery or Power source

Dimensions (H x W x D) (mm)

Weight (g)

Specifications

DC12V is supplied by the indoor unit.H*: HY(FUJITSU), HG(GENERAL)

Cassette type indoor unit can be controlledwith Wireless Remote Controller

WirelessRemote Controller IR Receiver Kit

UTY-LRH*B1

IR Receiver Kit

UTB-*WC

Necessary to control for all duct type by Wireless Remote Controller

IR Receiver Unit

Duct type indoor unit

WirelessRemote Controller

IR Receiver Unit

Built-in timersSelect from 4 different timer programs: On / Off / Program / Sleep Program timer: The program timer operates the ON and OFF timer once within a 24 hour period.Sleep timer: The sleep timer function automatically corrects the set temperature according to the time setting to prevent excessive cooling or heating during sleep hours.

System addressingDuring installation work, system addressing can be performed using the Wireless Remote Controller, thus eliminating manual switch setting.

WirelessRemote Controller

Indoor unit

Transmission line

Outdoor unit

*WC : YWC, TWC

Easy operation settingCode selector switch prevents indoor unit mix-up. (Up to 4 codes can be set.)

Wide and precise

Page 30: Meeting Various Needs with the FUJITSU GENERAL VRF ...winfinity.com.sg/wp-content/uploads/2016/07/Airstage-J-II.pdf · Meeting Various Needs with the FUJITSU GENERAL VRF AIRSTAGE

CONTROLLER

30

Group control of indoor units with simple operation

UTY-CGG*

•Up to 8 remote controller groups can be controlled by one Group Remote Controller.

•Up to 64 Group Remote Controllers can be connected in one VRF network system.

Group Remote Controller Max. controllable

64group R.C. in a VRF

network system

Max. controllable

8remote

controller groups

SpecificationsModel No. UTY-CGG*

DC 12V

120 x 120 x 18

200

Power Source

Dimensions (H x W x D) (mm)

Weight (g)

DC12V is supplied by a network converter.G*: GY(FUJITSU), GG(GENERAL)

•Network Convertor is required to connect Group Remote Controllers to a VRF network system.

(Network Convertor allows up to 4 Group Remote Controllers) Network Convertor

ON / OFF, Operating mode, Room temperature and Fan speed setting can be controlled / monitored centrally or individually.

High performance and compact sizeThe weekly timer is provided as a standard function.1. The timer can be set up for up to 4 times per day. (On / Off,

operating mode, set temperature)2. Allows separate settings for each day of the week.

Built-in weekly timers

Centralcontrol

ON/OFFcontrol

Weeklytimer

•Single Group Remote Controller controls and monitors up to 8 remote controller groups.

Control up to 8 remote controller groups

UTY-VGGX

Hotel

Restaurant

Lobby

Office & Lounge

NetworkConvertor

1

2

Group RemoteController

Group Remote Controller 1 : To control office floor and hotel floor (8 remote controller groups).Group Remote Controller 2 : To control hotel floor (5 remote controller groups).

Office floor

Wired Remote Controller

Office room

WirelessRemote

Controller

Meeting room

Hotel floor

WirelessRemote

Controller

Office room

Guest room

Simple RemoteController

Restaurant

Wired RemoteController

Lobby

WiredRemote

Controller

Page 31: Meeting Various Needs with the FUJITSU GENERAL VRF ...winfinity.com.sg/wp-content/uploads/2016/07/Airstage-J-II.pdf · Meeting Various Needs with the FUJITSU GENERAL VRF AIRSTAGE

31

UTY-DCG*

Central Remote Controller

Max. controllable

16groups

Max. controllable

100Indoor units

SpecificationsModel No. UTY-DCG*

Power Source

Dimensions (H x W x D) (mm)

Weight (g)

PACKING LIST

Packing List

Control Panel

DC 5 V

120 x 162 x 26

308

Power Supply Unit

100-240V, 50-60Hz, Single phase

99 x 135 x 40

355

Control Panel / Power Supply Unit / Connecting cable, etc.

G*: GY(FUJITSU), GG(GENERAL)

Central control of small- and medium-sized buildings and tenants.

• Individual control and monitor of 100 indoor units • 5 inch TFT color screen • User friendly view and easy operation • Automatic display switching for the number of connected units • Operation guidance display • Automatic switching of function menu• Corresponds to 7 different languages like English, Chinese, French, German, Spanish, Russian, Polish.

• It allows multiple indoor units grouping (Max.16 groups controlled)• Interlock with external device

• External input / output contact • Detachable power supply unit

System overview

Functions

Group : Division A Group : Division B

Group : Hallway

Group : Division C

Group : 3F

Emergency stop functionGroup : Tenant A Group : Tenant B Group : Tenant C

Group : 2F

• Individual control• Remote controller prohibition (All, On/Off,Mode, Temp.,Timer,Filter)• Room temperature set point upper and lower limitation

Diverse control of indoor units

• The control panel and power supply unit can be installed separately.

• For flexibility in installation, the Control panel can be built into the wall or fix on the wall.

Easy Installation

Control panel + Power supply unit

Control panel

CeilingPower supply unit

Power supplyunit

Wall

Wall

Controlpanel

SW BOX

Setting pattern 1 Setting pattern 2

Weekly timer

Weekday28°C 28°C26°C26°CSet temp.

Weekend 26°C26°C

Time8:00 12:00 13:00 18:00 21:00

Holiday 28°C28°C

Automatic clock adjustment

Page 32: Meeting Various Needs with the FUJITSU GENERAL VRF ...winfinity.com.sg/wp-content/uploads/2016/07/Airstage-J-II.pdf · Meeting Various Needs with the FUJITSU GENERAL VRF AIRSTAGE

CONTROLLER

32

UTY-DTG*

Touch Panel Controller

•Large-sized 7.5-inch TFT color•LCD Easy finger touch operation•Stylish shape and design to suit all application•No additional component is required for installation•Up to 400 indoor units can be controlled•Selectable 2 display types (Icon / List) in monitoring mode•Corresponds to 7 different languages, English, Chinese, French, German, Spanish, Russian, Polish.

Max. controllable

400indoor units

Real size screen image

• Large and wide-angled LCD is easily viewable even at a distance• Easy-to-understand icon-driven Graphical User Interface (GUI)• Wide range of simple-to-understand icons

• Operation can be selected using your finger or the dedicated touch pen by pressing the appropriate on-screen icon

• Up-to-date status display• Background color identifies current control operation Blue for

monitoring, green for operational control• Flat touch screen is easily cleaned• Non-glare coating on touch panel controller minimizes fingerprint

marking

Easy operation

Data transfer availableby USB

CSV format data edited by PC can be imported to Touch Panel Controller.

Versatility

Page 33: Meeting Various Needs with the FUJITSU GENERAL VRF ...winfinity.com.sg/wp-content/uploads/2016/07/Airstage-J-II.pdf · Meeting Various Needs with the FUJITSU GENERAL VRF AIRSTAGE

33

SpecificationsModel No. UTY-DTG*

100-240V 50/60Hz

260 x 246 x 54

2,150

USB 2.0

Power Source

Dimensions (H x W x D) (mm)

Weight (g)

Interface

G*: GY(FUJITSU), GG(GENERAL)

Group A Group B

Up to 400 indoor units can be controlled

System overview

Emergency stop controlAir conditioner can be turned off through the external input control

It allows multiple indoor unit grouping

Emergency stop function

• Up to 400 indoor units can be controlled• It allows multiple indoor units grouping• Schedule timer function is standard (20 patterns per day)• Emergency stop function(through the external input control)• Temperature upper and lower limit setting• The clock of each indoor unit correct setting

Functions

Touch Panel Controller is easily mounted to the wall. Flat back surface allows to be installed wherever it is needed.• Correctable mechanism for tilting (horizontal) after the installation of the body

No additional component is required for installation

• There is no need for the installation space of power supply adaptor and transmission adaptor etc.

Easy installation & maintenance

Flexible groupingIndividual control

Schedule control Indoor units operation monitoring

Automatic clock adjustment

The time setting of each controller can be set in batch automatically.

Switch boxMounted plate

Easy-to-remove front cover

Page 34: Meeting Various Needs with the FUJITSU GENERAL VRF ...winfinity.com.sg/wp-content/uploads/2016/07/Airstage-J-II.pdf · Meeting Various Needs with the FUJITSU GENERAL VRF AIRSTAGE

UTY-APGX

System Controller

User friendly view and operation

System Controller realizes the advanced integrated monitoring & control of VRF network system from small scale buildings to large scale buildings.

Monitor mode (Site)

Monitor mode (Building)

Monitor mode (Floor) Monitor mode (List) Schedule setting

Main operation monitoring screen Management functions Operation monitoring of each siteMonitoring located site

Max. controllable

1,600indoor units

Max. controllable

400outdoor units

Max. controllable

4VRF network systems

Software

• Up to a maximum of 4 VRF network systems, 1600 indoor units, and 400 outdoor units can be controlled.

• Supports VRF S series, V series, V-ll series and J-II series. • In addition to air conditioning precision control function, central remote control, electricity charge calculation, schedule management, and energy saving functions are strengthened and building manager and owner needs are met.

• Corresponds to 7 different languages (English, Chinese,French, German, Spanish, Russian, Polish)

On site central control

Remote central controlSystem Controller may be used on site or remotely over various networks for remote central control. System Controller requires 2 softwares working together. VRF Controller runs on site and communicate with VRF system. VRF Explorer runs remotely and provides user interface and communicate with the VRF Controller. VRF Controller and VRF Explorer program may run in a single PC or in different PCs separated by network. By using VRF Explorer software, one PC can perform central control of 10 VRF system sites with max. 20 buildings per site.

Remote centralized control

Max. 4 VRF network systems per site

Building Management Company A (In charge of the day shift)

Internetor

Telephone Lineor

LAN

Internetor

Telephone Lineor

LAN

Building management company,management center, etc.

BuildingManagement Company B

(In charge of the night shift)

Security Company

Headquarters Management Center

A maximum of 10 locations, such as offices or factories

1 VRF Explorer can control or monitor up to 10 sites.

1 VRF Controller can be monitored from any number of VRF Explorers (Up to 5 connections simultaneously).

Office Management Center

VRF Explorer

VRF Explorer

VRF Explorer

VRF ExplorerVRF Explorer

VRF Explorer

VRF Controller

VRF Controller

Internetor

Telephone Lineor

LANVRF Explorer

VRF Controller

Central Monitoring Screenfor all Properties

Special Property Detailed Monitoring Screen

34

CONTROLLER

Page 35: Meeting Various Needs with the FUJITSU GENERAL VRF ...winfinity.com.sg/wp-content/uploads/2016/07/Airstage-J-II.pdf · Meeting Various Needs with the FUJITSU GENERAL VRF AIRSTAGE

35

•Batched stop•Divers control of indoor units•Oprating & control record•Schedule control•Error display & E-mail nitification•Prohibition setting

Others

FunctionsEnergy saving management UTY-PEGX:software

Pow

er c

onsu

mpt

ion

Time

Outdoor unit capacityupper limit

Peak cut operationControls overall operation while maintaining comfort according to the overall power consumption target value.

Apportions the power used by indoor and outdoor units and automatically calculates the electricity charge for each tenant.When you want to calculate the power used during a certain period in hotels, etc., computation linked with an electric meter is also possible. (Option)

Outdoor unit capacity saveSets an upper limit of outdoor unit capacity and performs capacity save operation at peak times.

Indoor unit rotation operationReduces annual power consumption by operating indoor units in rotation.

Forced thermostat off range

Target power consumption

Outdoor unit stop range

Outdoor unit capacity control screen

Ideal control line (Use of average power consumption)

Shows change in power consumption by time

Indoor unit rotation screen

Electricity charge apportionment

OptionBilling management for users for a set period of time, such as for hotels

Signal transmission line

1Ø, 2wire 230V, 50Hz

DPM

System Controller

Outdoor unit

Room 301 Room 302 Room 303

Room 201 Room 202 Room 203

Room 101 Room 102 Room 103

CT

1Ø, 2

wire

23

0V, 5

0Hz

Option

SpecificationsModel No. UTY-APGX

Personal Computer

Operating System

CPU

HDD

Memory

Interface

Accelerator

Other Software Required

AT compatible machine that runs Microsoft® Windows®

Microsoft® Windows® XP Professional (Service Pack 3 or later / English version),Microsoft® Windows Vista® Home Premium, Business (Service Pack 2 or later / Corresponds to 7 different languages.*),Microsoft® Windows® 7 Professional (64-bit is not supported. / Corresponds to 7 different languages.*)*English, Chinese, French, German, Spanish, Russian, Polish

Intel® Pentium® / Celeron 2 GHz (VRF Controller), 1 GHz (VRF Explorer) or higher

40 GB or more of free space (5 GB for VRF Explorer PC)

2 GB or more (VRF Controller), 1 GB or more (VRF Explorer)

USB port is required for each of the followings for Server PC ;• Wibu Key (Software protection key) • Echelon® U10 USB Network Interface (Required for each VRF Network)Ethernet port is required for remote connection using internet.

Adobe® Reader® 9.0 or later

Requires the internal graphics accelerator be compatible with Microsoft® DirectX® 9.0

PACKING LIST

Wibe Key

CD-ROM

Personal computer must be field supplied. U10 USB Network Interface must be field supplied. Contact Echelon® Corporation or its local sales representative for detail.Product Name : U10 USB Network Interface - TP/FT-10 Channel Model Number: 75010R

Includes the software for System Controller. Both VRF Controller and VRF Explorer software is included.

Software protection key to be inserted in a USB slot running System Controller.System Controller may only run on a PC with Wibu Key. Remote VRF Explorer software does not require Wibu Key.

Page 36: Meeting Various Needs with the FUJITSU GENERAL VRF ...winfinity.com.sg/wp-content/uploads/2016/07/Airstage-J-II.pdf · Meeting Various Needs with the FUJITSU GENERAL VRF AIRSTAGE

36

CONVERTOR & ADAPTOR

UTY-VGGX

Network Convertor

•Split type systems can be controlled from a central remote controller or PC controller through connection to the VRF's network convertor. •Standard remote controller and central remote controller provide On / Off control, master control, temperature and fan control, etc.•A single network convertor can be used to connect and control up to 16 single units.

Installation example

•This network convertor is to be used for connecting single split system or group remote controller with the VRF network system.

•Please select the function by switching the dip switch during the installation.

* 2 refrigerant circuits can be covered by a single network convertor. Up to a total of 16 network convertors, Central remote controller and Touch panel controllercan be connected in one VRF network system.

Used for connecting Group Remote Controller

Big Multi

VRF networksystem

System Controller Single Split

Group of Single Split

4 group remort controllers can be connected to a single Network convertor.

VRF networksystem

Network Convertor

Group Remote Controller

Please consult your distributor for connectable split type air conditioner. Up to 100 network convertors may be connected in a single VRF network system. A single network convertor is considered as a single refrigerant system, irrespective of the number of connected single models.

Network Convertor

USBadaptor

SpecificationsModel No. UTY-VGGX

50-60Hz 220-240V

8.5

67 x 288 x 211

1,500

Power Source

Power Consumption (W)

Dimensions (H X W X D) (mm)

Weight (g)

Model No. UTY-VLGX

220-240V 50/60Hz

4.5

67 x 288 x 211

1,500

Power Source

Power Consumption (W)

Dimensions (H X W X D) (mm)

Weight (g)

Page 37: Meeting Various Needs with the FUJITSU GENERAL VRF ...winfinity.com.sg/wp-content/uploads/2016/07/Airstage-J-II.pdf · Meeting Various Needs with the FUJITSU GENERAL VRF AIRSTAGE

37

Network Convertor for LONWORKS®

BACnet® Gateway

Installation example

UTY-VLGX

•For connection between VRF network system and a LONWORKS® open network for management of small to medium-sized BMS and VRF network system.

•The unit permits central monitoring and control of a VRF network system from a BMS through a LONWORKS® interface.•Up to 128 Indoor units can be connected to one Network Convertor for LONWORKS®

Transmission specifications (BMS side)

UTY-ABGX

•The VRF network system can be incorporated into a Building Management System.•Enables central control of up to 1,600 indoor units through BACnet®, a global standard for open networks. •Conforms to ANSI / ASHRAE Standards® 135-2004 BACnet® Application Specific Controller (B-ASC) BACnet® / IP over Ethernet.

•Connects up to 4 VRF network systems (1,600 indoor units / 400 outdoor units) per gateway.•Supports VRF S/V series, V-II series and J-II series

78kbps

FT-X1 (Echelon® Corporation)

Free topology

None(It attaches at the terminal of a network.)

Transmission speed

Transceiver

Transmission way form

Terminal resistor

Software

CD-ROM(Software)

SoftwareProtection Key

Installation example

Lighting facilities

Security system

Automatic fire alarm interface

Ventilation system

BACnet Operator Workstation (B-OWS)

USB adaptor (Field supplied)

USB adaptor (Field supplied)

USB adaptor (Field supplied)

USB adaptor (Field supplied)CD-ROM

(Software)Software

Protection Key

(UTY-ABGX)BACnet Gateway

Outdoor unitIndoor unit

VRF network system 1

VRF network system 2

Indoor unit

BACnet

Max. 4 VRF network systems

*1: USB adaptor is U10 USB Network Interface of Echelon® Corporation.

®

®

®

= BACnet® Gateway for each system.= USB cable= Transmission line (VRF Network)= Ethernet

*1

Outdoor unit

Max. controllable

128indoor units

Max. controllable

4Units to BMS

Max. controllable

4VRF network systems

Max. controllable

400outdoor units

Max. controllable

1,600indoor units

General-purpose building control computer(LONWORKS® device)

LONWORKS® Network

NetworkConvertor

VRF network system 1 Lighting facilities

Security system

Automatic firealarm interface

Ventilation system

Max. 128 indoor unitsMax. 100outdoor units

Max. 4 NetworkConvertor

VRF network system 2

Max. 128 indoor unitsMax. 100outdoor units

The BACnet Gateway version 2.0 is eligible to display BTL Mark. Founded by BACnet International, BTL (BACnet Testing Laboratories) is an indication of worth trusting for its quality after passing the strict tests.

SpecificationsModel No. UTY-ABGX

Personal Computer AT compatible machine that runs Microsoft® Windows®

Microsoft® Windows® XP Professional (Service Pack 3 or later / Corresponds to 7 different languages.*)Microsoft® Windows Vista® Home Premium, Business (Service Pack 2 or later / Corresponds to 7 different languages.*)Microsoft® Windows® 7 Home Premium, Professional (Corresponds to 7 different languages.*)*English, Chinese, French, German, Spanish, Russian, Polish•64-bit version of Windows® are not supported.

Intel® Pentium® / Celeron®, AMD Athlon / Duron processor 2 GHz or higher

40 GB or more of free space

2 GB or more

USB port (x 2-5) is requiredEthernet port is required

Adobe® Reader® 9.0 or later

PACKING LIST

Packing List

Personal computer must be field supplied. U10 USB Network Interface must be field supplied. Contact Echelon® Corporation or its local sales representative for detail.Product Name : U10 USB Network Interface - TP/FT-10 Channel Model Number : 75010R

CD-ROM / Wibu Key

Operating System

CPU

HDD

Memory

Interface

Other Software Required

Page 38: Meeting Various Needs with the FUJITSU GENERAL VRF ...winfinity.com.sg/wp-content/uploads/2016/07/Airstage-J-II.pdf · Meeting Various Needs with the FUJITSU GENERAL VRF AIRSTAGE

38

Signal Amplifier

CONVERTOR & ADAPTOR

UTY-VSGX

Installation example

•Transmission Line length can be extended up to 3,600m for with multiple Signal Amplifiers.

•Up to 8 signal amplifiers can be installed in a VRF network system.•A signal amplifier is required,(1) When the total wiring length of the transnission line exceeds 500m.(2) When the total number of units on the transnission line exceeds 64.

UTY-TEKX

Installation exampleAuto mode operation, which switches the cooling and the heating automatically, is enabled by using the sensor switch and External Switch Controller. Note: All indoor units will operate in the same mode.

B

AE

Signal Amplifier

C

Electrical wiring

•In combination with a field supply Card-Key Switch or other sensor, the External Switch Controller allows control of the ON / OFF, Room temperature, Fan speed and Master control functions. This makes this product suitable for installations such as hotel rooms.

•Card-key or other sensor switches are available as a field supplied parts.

Air conditioner switching can be controlled by connecting other sensor switches

RemoteController

Line

Indoor Unit 1 2 3 E COM SW1 SW2

Card-key

Externalinput

RemoteController

Line

Indoor Unit 1 2 3 E COM SW1 SW2

Sensor SW

Externalinput

Card-key(Field supplied)

Sensor SW(Field supplied)

External Switch Controller

External Switch Controller

Note 1. Please choose a thermosensor switch which can be set up for T1 and T2.

Note 2. The remote controller's operation is prior to the auto mode operation.

Roo

m te

mp.

Time

T1

T2

Cooling

Heating

SU MO TU WE TH FR SA

7

3 126 9 15 18 21

T1 = ON, T2 = OFF

To individual dry contact

Sensor SW(Field supplied)

External Switch Controller (UTY-TEKX)

SpecificationsModel No. UTY-VSGX

220-240V 50/60Hz

4.5

67 x 288 x 211

1,500

Power Source

Power Consumption (W)

Dimensions (H X W X D) (mm)

Weight (g)

Model No. UTY-TEKX

DC 12V

120 x 75 x 30

90

Power Source

Dimensions (H X W X D) (mm)

Weight (g)

DC12V is supplied by the indoor unit.

External Switch Controller

Page 39: Meeting Various Needs with the FUJITSU GENERAL VRF ...winfinity.com.sg/wp-content/uploads/2016/07/Airstage-J-II.pdf · Meeting Various Needs with the FUJITSU GENERAL VRF AIRSTAGE

39

SERVICE & MONITORING

SpecificationsModel No.

Personal Computer

UTY-AMGXUTY-ASGX

AT compatible machine that runs Microsoft® Windows®

UTY-ASGX

UTY-AMGX

Wiring connection

•Operation status can be checked and analyzed to detect even the smallest abnormalities•Storage of data on system operation status on a PC allows access even from off site.•Up to 400 indoor units (a single VRF network system) can be controlled and monitored for large scale buildings or hotels•This software can be connected to any point of transmission line with USB adaptor (field supplied).•Supports VRF S/V series, V-II series and J-II series.

Extensive monitoring and analysis functions for installation and maintenance

Software

•Troubleshooting is performed by monitoring each air conditioning unit remotely during periodical system checks.•Error notification can be automatically transmitted to several locations using the internet*1.•Requires either a dedicated internet connection or public telephone line.•Determination of an error occurrence can be made through error warnings and equipment status information obtained from a remote location.•The monitoring data in a remote side can be optionally downloaded. And, this data can be displayed in offline mode of the service tool.•Monitoring side computer is not required to install special software, requires only general web browser.•Supports VRF S/V series , V-II series and J-II series.

Product features

(Field supplied)

Refrigerant piping

Tran

smis

sion

line

Indoor unit

Indoor unit

USB adaptor(Field supplied)

Functions•Equipment Detail (Diagram)

Support 4 VRF network systemsUSB adaptor (max. 4 adaptors per PC) permit, monitoring of up to 1,600 indoor units.Suitable for large-scale buildings or hotels.

VRF NetworkSystem 2

VRF NetworkSystem 3

VRF NetworkSystem 4

Indoor unitMax. 400

Indoor unitMax. 400

Indoor unitMax. 400

Indoor unitMax. 400

Web Monitoring System

Indoor unit

Transmission line

USB adapter(Field supplied)

Outdoor unit

WebMonitoring

Tool

USB adaptorsVRF Network System SideMonitoring Side

orInternet

PublicTelephone

Line

*1: Use of internet mail system required.

Max. Monitorand controll

100outdoor units

Max. Monitorand controll

400indoor units

VRF network systemcan be supported

41,600indoor units

can be supported

VRF NetworkSystem 1

Operating System

CPU

HDD

Memory

Interface

Software

Hardware

Microsoft® Windows® XP Professional (English version / Service pack 3 or later), Microsoft® Windows® Vista® Home Premium,Business Edition (English version), Microsoft® Windows® 7 Professional (64-bit is not supported. / English version)

1 GB (Vista, 7), 512 MB (XP) or more

USB port for U10 USB Network Interface and Software protection key. USB port (for U10 USB Network Interface Max.4, Software protection key)Following interface is required for remote connection:Public Telephone LIne : Modem is requiredInternet using LAN : Ethernet port is required

1 GB or more

Internet Explorer 6.0 or 7.0 or 8.0 / Adobe® Reader® 9.0 or later

CD-ROM drive

Intel® Pentium® / Celeron®, AMD AthlonTM / DuronTM 1 GHz or higher

10 GB or more of free space 40 GB or more of free space

PACKING LIST

Packing List

Personal computer must be field supplied. U10 USB Network Interface must be field supplied. Contact Echelon® Corporation or its local sales representative for detail.Product Name : U10 USB Network Interface - TP/FT-10 Channel Model Number: 75010R

CD-ROM / Wibu Key

Service Tool

SoftwareWeb Monitoring Tool

•Equipment Detail (List)•Operation History•Error History•Remote File Download•System List•Commissioning Tool•Network Topology Analyzer

•Remote setting•System Time Setting•Central Release•Model Name Writer•Error Memory Reader•Time Guard Information•Software Version acquire and display

Page 40: Meeting Various Needs with the FUJITSU GENERAL VRF ...winfinity.com.sg/wp-content/uploads/2016/07/Airstage-J-II.pdf · Meeting Various Needs with the FUJITSU GENERAL VRF AIRSTAGE

OTHERS

40

RFA data

Two kinds of model data, DXF data and RFA data, necessary in detailed design are offered. These data can be procured from the Fujitsu General web site and Design Simulator

2. 2D (DXF), 3D (RFA) contents data

FGL Web site

Design Simulator

for

FUJITSU VRF

Fujitsu General offers software which quickly performs model selection and creates material for model estimation in the VRF initial design stage. "Design Simulator" has functions which automatically select the proper model for the required capacity, automatically draft piping diagrams and wiring diagrams, and also automatically calculate the additional refrigerant charge amount, automatically generates the reports necessary for estimation. Operation is also easily performed by drag & drop and full-fledged model design estimates can be quickly made.

• Automatic model selection of indoor unit and outdoor unit• Simple drag & drop operation• Automatic generation of piping diagrams and wiring diagrams• Automatic calculation of additional refrigerant charge amount• Auto CAD Data (DXF), Revit Mep Data (RFA) export • Automatic report generation (Word, Excel)• Multi-language capability

Features

1. Quick model selection and design tool "Design Simulator" for VRF

VRF System Design

Page 41: Meeting Various Needs with the FUJITSU GENERAL VRF ...winfinity.com.sg/wp-content/uploads/2016/07/Airstage-J-II.pdf · Meeting Various Needs with the FUJITSU GENERAL VRF AIRSTAGE

41

Optional Parts

Controllers

Convertors / AdaptorsBACnet® Gateway

Wired Remote ControllerUTY-RNK*

Wireless Remote Controller

Simple Remote ControllerUTY-RSK*With operation mode

Simple Remote ControllerUTY-RHK*Without operation mode

UTY-LNH*IR Receiver UnitUTB-YWCUTB-TWC

For All Duct type

IR Receiver KitUTY-LRH*B1

For Cassette type

Group Remote ControllerUTY-CGG*

Network ConvertorUTY-VGGX

Network Convertor

Central Remote ControllerUTY-DCG*

for LONWORKS®

UTY-VLGXUTY-ABGX

Signal AmplifierUTY-VSGX

External Switch ControllerUTY-TEKX

Software

System ControllerUTY-APGX

Software

Touch Panel ControllerUTY-DTG*

K*:KY(FUJITSU), KYT(FUJITSU), KG(GENERAL), H*: HY(FUJITSU), HG(GENERAL), G*: GY(FUJITSU), GG(GENERAL)

CD-ROM (Software)

Software Protection Key

Page 42: Meeting Various Needs with the FUJITSU GENERAL VRF ...winfinity.com.sg/wp-content/uploads/2016/07/Airstage-J-II.pdf · Meeting Various Needs with the FUJITSU GENERAL VRF AIRSTAGE

OTHERS

42

Optional Parts

Connection Tube

Gas Pipe

Liquid Pipe

Gas Pipe

Liquid Pipe

Header

Model name3-6 Branches

UTR-H0908L

UTR-H0906L

3-8 Branches

UTR-BP090XSeparation Tube

UTR-H0908LHeader

UTR-H0906L

Gas Pipe

Liquid Pipe

Header

Others

FlangeRound

Square

RemoteSensor Unit

Long-Life Filter

Auto Louver Grille Kit

DrainPump Unit

Air Outlet Shutter Plate

Insulation Kit for High Humidity

EV Kit

Fresh AirIntake Kit

Wide Panel

Panel Spacer

Grill Kit

Indoor unit typeCompact

Duct Slim Duct Low StaticDuct Duct High Static

DuctCompactCassette

SlimCassette Cassette Floor /

Ceiling Ceiling Compact WallMounted

WallMountedItem

UTZ-PX1BBA

UTD-RS100 UTD-RS100

-

-

-

-

-

-

-

-

-

-

-

UTD-GXSB-W UTD-GXSC-W

-

-

-

-

-

-

-

-

-

-

-

UTD-LF25NA

UTD-RF204

UTD-SF045T

UTD-RS100

UTZ-PX1NBA

-

-

-

-

-

-

-

-

UTD-LF25NA

UTD-RF204 UTD-RF204

UTD-SF045T

UTD-RS100

UTZ-PX1NBA UTR-DPB24T

-

-

-

-

-

-

-

-

UTR-EV14XBUTR-EV09XB

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

UTD-LF60KA

UTD-RS100

-

-

-

-

-

-

-

-

-

-

-

UTR-YDZB

UTG-UFYC-W

UTZ-KXGC

UTZ-VXAA

-

-

-

-

-

-

-

-

-

UTG-AGYA-W

UTR-YDZC

UTG-UGYA-W

UTZ-KXGB

UTZ-VXGA

UTG-BGYA-W

-

-

-

-

-

-

-

UTG-AGYA-W

UTR-YDZC

UTG-UGYA-WUTG-UFGC-W UTG-UGGA-W UTG-UGGA-W

UTZ-KXGA

UTZ-VXGA

UTG-BGYA-W

-

-

-

-

-

-

- - - -

UTD-GXSA-W

Page 43: Meeting Various Needs with the FUJITSU GENERAL VRF ...winfinity.com.sg/wp-content/uploads/2016/07/Airstage-J-II.pdf · Meeting Various Needs with the FUJITSU GENERAL VRF AIRSTAGE

Flange (Round)UTD-RF204

Flange (Square)

Long-Life Filter

UTD-SF045T

Long-Life Filter

For Compact Duct type

For High Static Pressure Duct type

Drain Pump Unit

UTD-LF60KA

UTZ-PX1BBA

For Low Static Pressure Duct type /Duct type

UTZ-PX1NBA

For Low Static Pressure Duct type / Duct type

For Low Static Pressure Duct type / Duct type

For Low Static Pressure Duct type / Duct type / Ceiling type

For Ceiling type

Drain Pump UnitUTR-DPB24T

New amenity space can be offered by installing the Remote sensor.

For All Duct type

Remote Sensor UnitUTD-RS100

Panel spacer

50mm

Indoor unit950

Panel 600

600 (mm)

For Cassette type

Panel Spacer

For Cassette type

Wide Panel UTG-AGYA-W

UTG-BGYA-W

UTD-LF25NA

Shuts the air outlet when only using as 3 blow out.

For Compact Cassette type

Air Outlet Shutter PlateUTR-YDZB

For Compact Cassette type

Grille KitUTG-UFYC-WUTG-UFGC-W

For Cassette type

Grille KitUTG-UGYA-WUTG-UGGA-W

UTR-EV09XB (for AS*E07/09LACH)UTR-EV14XB (for AS*E12/14LACH)

For Compact Wall Mounted type(EEV external type)

EV Kit

Shuts the air outlet when only using as 3 blow out.

For Cassette type

Air Outlet Shutter PlateUTR-YDZC

Insulation Kit

Insulation Kit for High HumidityUTZ-KXGAUTZ-KXGBUTZ-KXGC

For Cassette typeFor Slim Cassette typeFor Compact Cassette type

For Cassette type

Fresh Air Intake KitUTZ-VXGA

For Compact Cassette type

Fresh Air Intake KitUTZ-VXAA

Auto Louver Grille KitUTD-GXSA-W (for ARXD07/09/12/14LATH)UTD-GXSB-W (for ARXD18LATH)UTD-GXSC-W (for ARXD24LATH)For Slim Duct type

43

Page 44: Meeting Various Needs with the FUJITSU GENERAL VRF ...winfinity.com.sg/wp-content/uploads/2016/07/Airstage-J-II.pdf · Meeting Various Needs with the FUJITSU GENERAL VRF AIRSTAGE

The colors may be different from the actual colors because this catalog is printed matter.Product specifications are subject to change without notice.

Distributed by :

“ ” is a worldwide trademark of FUJITSU GENERAL LIMITED and is a registered trademark in Japan, the U.S.A. and other countries or areas.*Echelon®, LONWORKS®, and the Echelon logo are trademarks of Echelon Corporation registered in the United States and other countries.*BACnet® is a registered trademark of the American Society of Heating Refrigeration and Air Conditioning Engineers (ASHRAE).

6NNJ22-1201E

1116, Suenaga, Takatsu-ku, Kawasaki 213-8502, Japanhttp://www.fujitsu-general.com/

Copyright© 2011 Fujitsu General Limited. All rights reserved.

Fujitsu General (Thailand) Co., Ltd.

ISO 9001Certified number : 01 100 89394

ISO 14001Certified number : 01 104 9245101

Fujitsu General (Shanghai) Co., Ltd.

ISO 9001Certified number : 01 100 79269

ISO 14001Certified number : 272043

Fujitsu General Central Air-conditioner (Wuxi) Co., Ltd.

ISO 9001Certified number : 00608Q11061R2M

ISO 14001Certified number : 00609E20454R2M