the GCe BusinessGCE has almost 100 years of experience in the manufacture and supp-ly of high pressure gas equipment. During this time the GCE product range has increased dramatically. Today´s product portfolio fits a large variety of applications, from simple pressure regulators and blowpipes for cutting and welding to highly sophisticated gas supply systems for the medical, electronic and analytical industries.

GCE GrOUp InCLUDEs fOUr bUsInEss ArEAs:• Cutting & Welding• Process Application• Medical• High Purity

OriGinsThe origins of GCE (Gas Control Equipment) go back to the start of the 20th century when Gas Welding was first invented. The GCE group was formed as an independent company in 1987 through the merging of two of the worlds leading gas and welding companies into one inde-pendent unit. GCE has grown rapidly since its establishment and is leading the restructuring of the European gas equipment industry through mergers and acquisitions. Through its extensive Research and Development programs GCE has set standards that have become the benchmark for the whole industry.

GCe serviCesThe main industrial customers for GCE are wholesalers and local distri-butors. However in some markets GCE distributes equipment with the full cooperation of the main gas supplier for that market.

For these companies GCE provides both commercial and technical support. A significa t part of the sales volume in this area also comes from key end user accounts such as shipyards, repair shops, OEM custo-mers and welding machine manufacturers.

A COMPLete rAnGe FOr MeDiCALThe supply of Medical Gas Equipment is a very important part of our business. All Medical Gas Applications require the highest safety stan-dards, specialised knowledge and a full understanding of patient re-spiratory requirements. GCE fully complies with the European Medical Directive 93/42/EEG and the QSR (Quality System Regulations known as the GMP standards).Western Europe is the traditional market for a whole range of products for all different types of customers and together with the growing Eas-tern European market, these are GCE’s main sales area. Our sales force is also active in a number of other markets including North and South America, North Africa and the Middle East, and continues to expand to other parts of the world, such as China and India. As a result, our pro-ducts are designed in accordance with the requirements of all Europe-an standards as well as those of other regions where they will be used.Supplies to the major Gas Companies account for the majority of sales however in each market various distributors, healthcare providers, hos-pitals and other manufacturers of medical also play a significa t role in the distribution of GCE-branded and CE-marked products.GCE supply complete systems for supplying oxygen, nitrous oxide, other gases and vacuum to hospitals, ambulance service providers, emergency services and home care providers, as well as other special services using this equipment.

Sales o˘c e Sales representation Headquarters Production units Stock point

www.gcegroup.com

Page 3: MEDICAL CATALOGUE

1

COnTEnTsCOMBi vALves 4

MediVital®. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5

hiGh Pressure reGuLAtOrs 8MediSelect® II . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9Single Stage Therapy Regulators . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10Dual Stage Therapy Regulator . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10Select Flow . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12Resuscitation Regulator . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12Demand Regulator . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12Therapy Regulator . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13Spare parts . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13

hOsPitAL wArD equiPMent 17Vacuum Regulator - Medievac+ . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17Accessories for Medievac . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17Flexiunit . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19ACCESSORIES - Suction Bottles - WITH SINGLE USE BAGS. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20ACCESSORIES - Suction jars - MediCollect 2000 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20Flowmeter - MediMeter . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 22Mediflow Ultra II (Low Pressure Regulator) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 24ACCESSORIES - MediWet II Humidifier . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 25

hOMeCAre 27ELITE - Pneumatic Gas conServer . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 29ECOlite® 4000 Oxygen Conserver . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 31Inogen One® G2 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 32Inogen One® G3 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 32Nuvo Lite Oxygen Concentrator . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 33Nuvo 8 Concentrator . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 33

eMerGenCy equiPMent 35Demand Valves - EASE II . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 37Ambulance panel II . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 39GSS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 41Portaflow . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 42Portaflow Valve . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 42MARS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 43Net head harness . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 43Oxygen Cylinders . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 43Bags and accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 44

MisCeLLAneOus 45Medical Cylinder Valves . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 45

serviCinG OPtiOns 46CertiFiCAtes 47GenerAL Business terMs AnD COnDitiOns 48

Page 4: MEDICAL CATALOGUE

2

GCE LATIN AMERICA

REGIONAL OFFICEPo. Box: 0843-01211 Dakris pl. 6408 Los Ríos, Ciudad de Panamá

Tel: +507 317 61 68 Fax: + 507 317 65 00

Email: [email protected]

www.gcegroup.com

COMbI VALVEs

Page 5: MEDICAL CATALOGUE

COMbI VALVEs

Page 6: MEDICAL CATALOGUE

4

•Available in different variants, they are designed to fulfil the equirements for all types of medical gases in different application areas and cylinder pressures up to 300 bar

•Gas from the cylinder is first ontrolled by the shut-offvalve and then passes through the pressure regulator and delivered to the patient through the fl w outlet or the pressure outlet

•They are always provided with an external pressure relief valve to protect the user outlets from over pressure

•Available with a protective guard and bed hanger for easier and safer handling by the healthcare personnel and patients.

15 yeArs LiFe tiMe •15 year life time ensured by extended endurance and cycle

testing for future market requirements

•Slow opening shut off alve with new Patented design

•Latest technology highest shock resistant gauge

•Flow selector designed for optimal gas fl w and patient safety

•Guard design provides maximum protection for the valve

COMbI VALVEsVALVEs InTEGrATED wITh prEssUrE rEGULATOr

MediVital®

Pressure inDiCAtOr•Good visibility of values/status•Wide dial angle improving readability•40 mm diameter

•Fluorescent scale face

eAsy use FLOw seLeCtOr•Excellent view of all selected fl ws•Large clear 4,5 mm digits •Optimized ergonomics of hand wheel •Increased fl w in between settings (min 50% of lower value)•Fixed arrow for fl w indication on the front of the valve•Increased clearance around hose nipple, enables easy connnection/ disconnection of cannula/mask•Facility for RF chip inside the fl w control knob

bEnEfITs fOr EnD UsErs shut OFF vALve•Clear visibility of open/close status – colour indication•Good visibility of open/close direction•Space for RF chip inside the hand wheel

Pressure OutLet•Completely enclosed & protected by the guard •Open/close push system with wide plastic grips for easy operation, for all main types •Improved design for primary types

Page 7: MEDICAL CATALOGUE

5

COMbI VALVEs - VALVEs InTEGrATED wITh prEssUrE rEGULATOrMediVital®

user FrienDLy•Suitable for use in Homecare, Emergency and Hospital applications•Easy read fl w selector and gauge • Shut off alve with clear open/closed status & colour coded marking• Ergonomic guard design allows for easy handling of the cylinder package• Compact and lightweight design less than 1150 grams• Easy clean guard material

hiGhest sAFety•Testing in accordance with the following standards; ISO 10534-3 ASTM G175 Pill test

• ISO 10297

• CE Marked CE 0434 in accordance with the medical directive 93/42/EC and TPED 2010/35 EU

• Phthalate and Halogenated polymer free components

• MRI compatible up to Tesla 3

• For use with oxygen, nitrous oxide and other medical mixed gases up to 300bar working pressure

teChniCAL DAtAGas: O2, Air, N2O/O2 and other medical mixed gasesInlet pressure: Up to 300 bar (4500 psi)Outlet pressure: 3,6 to 5,5 bar - acc. to EN ISO 10524-3 (or per customer specification)RPV closing: >3 barPRV opening and re-closing: >5.5 barFlow ranges: 0-2, 0-6, 0-15 and 0-25 lpmMaterials: Metallic parts (gas wetted): brass Elastomers: EPDM, silicon, PUR Plastics: PA66, PEEK, PI Springs (gas wetted): CuBe2, CuSn6Dimensions: Height: 153 mm; Width: 112 mm; Depth: 118 mmWeight:* 1150 g Inlet stem: Tapered or parallel threads (17E, 25E, M18, per customer specification)Filling port: ISO 5145, NEVOC or per customer specificationRegulatory status: Complies with MDD 93/42/EEC Complies with TPED 99/36/EEC Complies with EN ISO 10524-3 Complies with ISO 10297 Complies with EN 1789 Complies with ASTM G175 Production in accordance with EN ISO 9001 and EN ISO 13485Classification: IIbManufacturer: GCE s.r.o, Žižkova 381, 583 81 Chotěboř

* Standard Combivalve (flow control unit 0 - 15 l/min, flow outlet, DIN quick coupling pressure outlet) with guard. All technical data are given for information only and are subject to modifications by the manufacturer.

UsEr frIEnDLy

Page 8: MEDICAL CATALOGUE

hIGh prEssUrE rEGULATOrs

Page 9: MEDICAL CATALOGUE

hIGh prEssUrE rEGULATOrs

Page 10: MEDICAL CATALOGUE

8

ThE nEw GEnErATIOn Of MEDICAL hIGh prEssUrE GAs rEGULATOrs

hIGh prEssUrE rEGULATOr

MEDIsELECT® II

Rotating pressure gauge which allows convenient reading

Continuous fl w between settings, in the unlikely event of mechanism failure

•Regulator with fl w selector•Rotating pressure gauge which allows convenient reading•360° swivelling outlet – it enables better orientation of the nasal cannula or oxygen mask towards the patient

(preventing from twisting)• Innovative self centering fl w setting device with continuous fl w between settings. In the unlikely event of

indent mechanism failure, the patient will still be supplied with medical gas•Lateral and frontal reading of fl w settings•Higher number of fl w disc holes increases treatment options

Extra fl w setting of 25 lpm on the traditional 15 lpm variant, allows use in resuscitation•The additional 7 lpm is intended for nebulization

Two windows - frontal and lateral allow very good visibility of set values

360°

360°

360° swivelling outlet alows wider use of positioning

Page 11: MEDICAL CATALOGUE

9

hIGh prEssUrE rEGULATOrsMEDIsELECT® II

The Mediselect range of regulators are available in both Pin Index and 5/8“ BSP Bullnose connection with a universal fir tree low pressure outlet compatible with all oxygen therapy tube diameters.Mediselect regulators are manufactured from nickel plated brass and offer high levels of accuracy and ease of operation. They incorporate both sintered bronze filters and pressure relief valves, minimising the risks of contamination and increasing the level of carer and patient safety. Models are manufactured with two or nine pre-adjusted flow rate settings. Optional quick release BS 5682 Schrader sockets are available on some models. Fir tree outlets unscrew to leave 9/16” outlets compatible with most types of accessories eg. humidifiers.

ThErApy fLOw rEGULATOr rAnGE

Art. Nr. Description 0720246 Medi-select II (0,1,2,3,4,5,6,7,9,12,15,25 l/min) Pin Index Inlet Connection 0720247 Medi-select II (0,1,2,3,4,5,6,7,9,12,15,25 l/min) Bullnose Inlet Connection

ThErApy fLOw & QUICk rELEAsE COnnECTOr rEGULATOr rAnGEArt. Nr. Description 0720252 Medi-select II (0,2,4 l/min) Bullnose Inlet Connection 0720248 Medi-select II (0,1,2,3,4,5,6,7,9,12,15,25 l/min) Pin Index Inlet Connection Fitted with Single BS5682 Quick Release Connector0720249 Medi-select II (0,1,2,3,4,5,6,7,9,12,15,25 l/min) Bullnose Inlet Connection Fitted with Single BS5682 Quick Release Connector0724151 O2/N2O Regulator, Pin Index, Single BS 5682 Quick Connection Outlet0724195 O2/N2O Regulator, Bullnose Inlet Connection, Single BS 5682 Quick Connection Outlet

teChniCAL DAtAGas O2, Air, N2O/O2

Inlet pressure range up to 200 bar (depending on gas type) Nominal outlet pressure 4 barFlow ranges* 0 to 2 lpm 0-0,1-0,2-0,3-0,4-0,5-0,6-0,7-0,8-1-1,5-2 0 to 6 lpm 0-0,25-0,5-0,75-1-1,5-2-2,5-3-4-5-6 0 to 25 lpm 0-1-2-3-4-5-6-7-9-12-15-25Body material nickel-plated brassControl knob polyamideO-rings EPDMFilter sintered bronzeGauge cover TPE (thermoplastic elastomer)Weight app. 0,8 kgRegulatory status Complies with Medical Devices Directive 93/42/EEC. Complies with EN 10524-1 (Pressure regulators for use with medical gases) Complies with Standard EN 1789:2000 (Medical vehicles and their equipment - Road ambulances)

* Flowrates expressed at 23°C and 101,3 kPa

sPAre PArtsArt. Nr. Type 9419640 O-ring for outlet hose nipple 9/16 UNF, 10 pcs9438050 O-ring 9,19×2,62, 10 pcs9421560 Gasket for pin index connection, 10 pcs

FLOw Curve FOr OxyGen (P2 = 4 BAr)

Oxygen

Flow Q [l/min]

Outlet pressure p2 [bar]

Page 12: MEDICAL CATALOGUE

10

sInGLE sTAGE ThErApy rEGULATOrs

The Mediselect range of therapy regulators operate on the indirect single stage fixed pressure principle. These cylinder-mounted regulators (for use with oxygen, and air) are pre-set to 4 bar during production and locked with a tamper proof seal. These different gas version medical regulators can be used for hospital and emergency use.A pressure gauge is incorporated to register the pressure of gas entering the regulator, giving indication of the cylinder contents.All regulators are supplied with a 5/8” BSP Bullnose inlet connection, standard 3/8” or quick release BS5682 Schrader socket outlet connection and a pressure relief valve.

OxyGEn

Art. Nr. Description0781661 Mediline S400 Regulator Bullnose Inlet, BS5682 Quick Release Coupling0781660 Mediline S400 Regulator Bullnose Inlet, 3/8“ Outlet

MEDICAL AIr

Art. Nr. Description0781666 Mediline S400 Regulator Bullnose Inlet, BS5682 Quick Release Coupling

DUAL sTAGE ThErApy rEGULATOr

MEDICAL AIr

Art. Nr. Description0762169 Mediline M1000 Reg, Bullnose, BS5682 Quick Release Coupling, 7 Bar

OxyGEn

Art. Nr. Description0762170 Mediline M1000 Reg, Bullnose, BS5682 Quick Release Coupling, 4 Bar

Page 13: MEDICAL CATALOGUE

11

hIGh prEssUrE rEGULATOr

GCE sAbrE MEDICAL rEGULATOrs•The range covers the widest possible combination of inlet and outlet connections • Includes products designed for oxygen therapy, for use with gas powered resuscitation and on

demand equipment•All offer unrivalled levels of accuracy and performance whilst maintaining Sabre’s design brief of

robust and simple to operate products leaving the carer to concentrate on their patient – not on remembering how to use the equipment

•They incorporate both sintered bronze fil ers and pressure relief valves, minimising the risk of contamination and providing increased carer and patient safety

Page 14: MEDICAL CATALOGUE

12

sELECT fLOw

There is a comprehensive range of standard flow rate options on single, two and eleven flow Select Flow regulators.

pIn InDEx VErsIOnsArt. Nr. Description 1068790 Select Flow with a firtree outlet, flow rates 1, 2, 3, 4, 5, 6, 8, 10, 12, 15, ~23 l/min.1068792 Select Flow with a firtree outlet, flow rates 0.1, 0.25, 0.5, 0.75, 1, 1.5, 2, 2.5, 3, 4, 5 l/min.1068793 Select Flow with a firtree outlet, flow rates 0.1, 0.2, 0.3, 0.4, 0.5, 0.6, 0.7, 0.8, 0.9, 1.0, 1.1 l/min.1068794 Select Flow with a firtree outlet, flow rates 0.5, 0.8, 1, 2, 3, 4, 5, 6, 8, 10, 12, 15 l/min.1068812 Select Flow with a firtree outlet, flow rates 8 & 15 l/min.

bULLnOsE (5/8“)Art. Nr. Description 1068589 Select Flow with a firtree outlet, flow rates 1, 2, 3, 4, 5, 6, 8, 10, 12, 15, ~23 l/min.1068592 Select Flow with a firtree outlet, flow rates 0.1, 0.25, 0.5, 0.75, 1, 1.5, 2, 2.5, 3, 4, 5 l/min.1068593 Select Flow with a firtree outlet, flow rates 0.1, 0.2, 0.3, 0.4, 0.5, 0.6, 0.7, 0.8, 0.9, 1.0, 1.1 l/min.

teChniCAL DAtAGas O2

Input pressure up to 200 bar Therapy outlet firtree Therapy pressure 1.6 bar (23psi) Weight (no outlets) app. 0,51 kg

rEsUsCITATIOn rEGULATOr

Available with the full range of high pressure inlet connections.Sabre Resuscitation Regulators are designed for use with gas powered resuscitation products. One or two regulated outlets can be fitted to each regulator in addition to a Select Flow therapy outlet providing both resuscitation and therapy from the one regulator.

pIn InDEx VErsIOnsArt. Nr. Description1065859 Resuscitation Regulator with a single BS 5682 quick connector outlet and firtree outlet with flow rates 1, 2, 3, 4, 5, 6, 8, 10, 12, 15, ~23 l/min.

bULLnOsE (5/8“)Art. Nr. Description1065716 Resuscitation Regulator with a single BS 5682 quick connector outlet and firtree outlet with flow rates 1, 2, 3, 4, 5, 6, 8, 10, 12, 15, ~23 l/min.

teChniCAL DAtAGas O2

Input pressure up to 200 barTherapy outlet FirtreeTherapy pressure 1.6 and 4.2 bar (60psi)Weight app. 0,72 kg

DEMAnD rEGULATOr

Designed to provide the higher flow rates that ‘on demand’ medical gas products require.

Art. Nr. Description1046542 Demand Regulator with Bullnose inlet (5/8“) and BS 5682 quick connection outlet.1046574 Demand Regulator with Pin Index inlet and BS 5682 quick connection outlet.

Page 15: MEDICAL CATALOGUE

13

ThErApy rEGULATOr

This simple, high pressure regulator is suitable for inlet pressure of up to 200 bar and designed for use with traditional floating ball flow control devices. Available with the full range of high pressure inlet connections, Sabre Therapy Regulators combine all the benefits of simplicity, robustness and reliability common to the Sabre range.

pIn InDEx VErsIOns Art. Nr. Description1071001 Therapy Regulator, Pin Index with BS 5682 quick connection outlet.1070998 Therapy Regulator, Air, Pin Index with 3/8“ outlet.2004007 Therapy Regulator, Air, Pin Index with BS 5682 quick connection outlet.1071027 Therapy Regulator, Brass, Pin Index with 3/8“ outlet.

bULLnOsE (5/8“)

Art. Nr. Description1070989 Therapy Regulator, Bullnose with BS 5682 quick connection outlet.2008449 Therapy Regulator, Brass, Bullnose with 3/8“ outlet and flowmeter with 0 - 15 l/min scale.

spArE pArTs

Art. Nr. Description 1028228P O-ring (10pcs)1023713 Valve key & cord for PI regulator (1pc)

Page 16: MEDICAL CATALOGUE

hOspITAL wArDEQUIpMEnT

Page 17: MEDICAL CATALOGUE

hOspITAL wArDEQUIpMEnT

Page 18: MEDICAL CATALOGUE

16

sUCTIOn EQUIpMEnT

MEDIEVAC+•Compact and lightweight medical vacuum regulator system, which allows the user to effici tly and safely

control suction therapy•The suction level of the Medievac+ is regulated via an easy accessible, front mounted control knob•A special feature of the Medievac+ on-off alve is easy resumption of the selected de-pressure value, when

the treatment is interrupted •The Medievac+ gauge can easily be rotated, allowing the vacuum pressure to be clearly viewed

by the operator•The gauge scale is colour coded in sections to display a clear indication of suction level•Two versions of adjustable pressures are available to cover all therapy needs(-250 and –1000 mbar)•The –250 mbar version has a safety valve, which will automatically shut off o guarantee maximum protection

of the patient, in the unlikely event of de-pressure increase

the COMPACtness OF the DeviCe OFFers:•Fast connection to the vacuum source•Quick and convenient mounting of accessories (for example safety jar)•Good accessibility of other devices connected to close located terminal units

Diagonal orientation of ON/OFF switch

Safety valve (- 250 mbar)for protection of the patient

360°

Page 19: MEDICAL CATALOGUE

17

hOspITAL wArD EQUIpMEnTVACUUM rEGULATOr - MEDIEVAC+

Art. Nr. Description 0735106 Medievac+ 250 with standard probe0735105 Medievac+ 600 with standard probe0735104 Medievac+ 1000 with standard probe

teChniCAL DAtAON-OFF function ON : green button visible to switch On: push on the red buttonMax. inlet pressure - 950 mbar (Measured from atmospheric pressure)Max. suction flow 70 l/min ±5 l/minAccuracy of gauge ±2,5 % of full scaleSafety valve Medievac+ 250 only max. - 290 mbar openingInlet connection According to the respective national standardOutlet connection G1/2” maleHeight 133 mm; 260 mm (with safety jar)Width 63 mmDepth 77 mm (without connector)Body material ABSRegulatory status Complies with Medical Devices Directive 93/42/EEC. Complies with EN ISO 10079-3 (Medical suction Equipment, Part 3: Suction equipment powered from a vacuum or pressure source)

ACCEssOrIEs fOr MEDIEVAC

The Medievac+ vacuum regulator system includes an optional accessory, the safety jar. It is an additional protection of the vacuum regulator and the hospital vacuum network, when the collection jars overflow. The filling capacity of 100 ml and the safety valve function, provide the user with extra time to stop the suction therapy.

The jar can be easily and safely disconnected from the vacuum regulator and autoclaved at 134 °C for 18 minutes, in line with hospital protocols. GCE Mediline also recommends the use of the front mounted filter that is connected on the safety jar for increased safety. The plastic shell of the filter is very convenient to mount; it enables hygienic handling as direct contact with the membrane is avoided. The use of this filter is also recommended by the standard (EN ISO 10079-3 part 6.5.2.1). Medievac+ compliance is based on EN ISO 10079-3 standard.

Art. Nr. Description548900291594 Safety jar 100 ml 548900291595 Safety jar 100 ml including filter K291603 Filter (x10)K293492 Hose nipple G1/2 + o-ring

Page 20: MEDICAL CATALOGUE

18

sUCTIOn EQUIpMEnT

MEDIEjECT•The suction ejectors Medieject-32 and Medieject-33 come with either a metal bracket for rail mounting or

a quick coupling for direct connection to gas outlet•The negative pressure can be seen clearly on the front-mounted gauge•The suction ejector has an ON/OFF control knob•The suction effect is regulated with a needle valve• It has a low sound level and requires a minimum of maintenance

Page 21: MEDICAL CATALOGUE

19

fLExIUnIT

fLExIUnIT The Flexiunit is the Mediline Mediselect 15 regulator, with the venturi suction ejector fitted directly to it. Allowing 0 to 15 l/min free flow oxygen and a powerful, effective, fully adjustable 0 to -80 kPa suction. A quick release outlet connector can be fitted as an optional extra, enabling a ventilator , demand valve etc to be powered from the unit.The Flexiunit can be fitted with both Pin Index and Bullnose inlet connections to suit all standard cylinders.

Art. Nr. Description0720250 Flexiunit Combined Suction/0-15 l/min Pin Index Connection0720251 Flexiunit Combined Suction/0-15 l/min Bullnose Connection

teChniCAL DAtAMaximal suction effect -80 kPa (-0,8 bar)Capacity >25 l/minMaximum consumption of gas 38 l/minDimensions (w×h×d) 105×115×102 mm (mounting in gas outlet version)

Page 22: MEDICAL CATALOGUE

20

ACCEssOrIEs - sUCTIOn bOTTLEs - wITh sInGLE UsE bAGs

suCtiOn BOttLes - sinGLe useD BAGsArt. Nr. Description 373234560 Suction bottle 2 l Complete with lid373234559 Suction bag 2 l (20 pcs)325113335 Suction bottle 1 l Add lid art. no. 325111944 to make complete325111952 Suction bag 1 l (20 pcs)

ACCessOriesArt. Nr. Description 373234593 Connection for suction bag325113237 Silicone hose; 25m; 6×129435440 Silicone hose; 5m; 6×129435450 Silicone hose; 1m; 6×12325111944 Lid for suction bottleK291538 Catheter holder (without plate) K291539 Catheter holder (with plate)

373234560 325113335

373234559 325111952

325111944373234593

ACCEssOrIEs - sUCTIOn jArs - MEDICOLLECT 2000

Medicollect 2000 is a range of reusable jars for collection of secretion. For protected and hygienic use of unbreakable material, guaranteed airtight, with an overflow valve and autoclavable material.

Art. Nr. DescriptionK291530 Medicollect 2000 ml with lid (121°C) K291620 Medicollect 2000 ml with lid (134°C)K291540 Medicollect 1000 ml with lid (121°C) K291619 Medicollect 1000 ml with lid (134°C)

COnsuMABLesArt. Nr. DescriptionK006968 Manual vacuum stop device, non sterile for adults

teChniCAL DAtADimensions Height 302 x Ø 135x Ø130 mmWeight 0,6 KgCapacity 2 lPressure Maximum applicable 950 mbar Minimum applicable 100 mbarMaximum flow 100 l/minAnti-overflow arrangement Ball valveMaterial Jar: polysulphone (134°C), polycarbonate (121°C) Lid: polypropylene Hose nipples: chrome plated brass. Connections Hose nipples - Ø 9 mmCleaning Use a non abrasive cloth moistured with a neutral detergent immerged at 10% in hot water, < 60ºC. Rince in pure water and dry well. Never use solvents. Autoclave at 121°C for 20 minutes for polycarbonyte and 134°C for 18 minutes for polysulfone.Maintenance Check air tightness every six months or every five cleaning cycles. Check the overflow valve every six months or every ten cleaning cycles.Durability Maximum 30 autoclave cycles.

K291530

K291538 K291539

K291620

Page 23: MEDICAL CATALOGUE

21

fLOw-METErInG DEVICE

MEDIMETEr•Medimeter is a fl wmeter intended for control and measurement of fl w of air or oxygen administered

to patients•Flat surface flo t allows easy and safe reading of fl w values by the users•Ergonomic design, easy for cleaning•Available with probe connector, rail mounting with a hose and twin versions•Soft closing mechanism•Robust flo t, resistant against impact•New scale - better reading of fl w values

Page 24: MEDICAL CATALOGUE

22

fLOwMETEr - MEDIMETEr

The Medimeter is a pressure compensating flow meter giving clear indication of flow rates which are controlled by a fully adjustable needle valve. The most common version used is the 0-15 l/min for both oxygen and air. The durable brass body is nickel plated with a polycarbonate flow tube making it both tough and easy to clean.

OxyGenArt. Nr. Description 0730121 Medimeter 5 (0-5 l/min) with standard probe0730122 Medimeter 15 (0-15 l/min) with standard probe0730123 Medimeter 30 (0-30 l/min) with standard probe0730124 Medimeter 15 (0-15 l/min) Twin with standard probe

MeDiCAL AirArt. Nr. Description0730125 Medimeter 15 (0-15 l/min) with standard probe

teChniCAL DAtAGas O2, AirInlet pressure 4,5 barFlow ranges 0 - 5 lpm 0 - 15 lpm 0 - 30 lpmBody material Nickel-plated brassO-rings EPDMControl knob PolyamideBody dimensions Width 32 mm Height 160 mm Depth 60 mm Weight 280 g (without connector)Temperature range Storage - 30 °C to + 60 °C Operation - 20 °C to + 60 °CRegulatory status Complies with medical devices directive 93/42/EEC Complies with EN 15 002 (Flow - metering devices for connection to terminal units of medical gas pipeline systems)

ACCessOriesArt. Nr. DescriptionK294402 MediWet 200 134°C G 9/16

sPAre PArtsArt. Nr. Denomination9437250 External tube (10 pcs)9454170 O-ring (20 pcs)9423250 Hose nipple 9/16 UNF with o-ring (10 pcs)

Standard version with probe

Duo version with probe

Page 25: MEDICAL CATALOGUE

23

Independence of the pressure flu tuation with inlet pressure range of 2,8 – 8 bar

Continuous fl w between settings, in the unlikely event of mechanism failure

Two windows - frontal and lateral al-low very good visibility of set values360°

360° swivelling outlet alows wider use of positioning

MEDIfLOw® ULTrA II Is ThE nEw GEnErATIOn Of MEDICAL fLOw sELECTOr DEVICE wITh bUILT-In rEGULATOr

• It covers a comprehensive combination of inlet and outlet connections and offers various options for all medical applications, from neonatal care through to resuscitation

•Built-in regulator provides a very stable and precise fl w, independent of the pressure in the medical central gas system or cylinder

• Innovative self centering fl w setting device with continuous fl w between settings. In the unlikely event of indent mechanism failure, the patient will still be supplied by medicinal gas

•Lateral and frontal reading of fl w settings•360° swivelling outlet – it enables better orientation of the nasal cannula or oxygen mask towards the patient

(preventing from twisting)•Higher number of fl w disc holes increases treatment options. Extra fl w setting of 25 lpm on the traditional

15 lpm variant, allows use in resuscitation. The additional 7 lpm is intended for nebulization•Ergonomic and streamlined design

fLOw-METErInG DEVICE

MEDIfLOw® ULTrA II

Page 26: MEDICAL CATALOGUE

24

MEDIfLOw ULTrA II (LOw prEssUrE rEGULATOr)

Art.Nr. Type 0728187 Mediflow® Ultra II with flow rates 0-2 l/min0728168 Mediflow® Ultra II with flowrates 0-6 l/min0728173 Mediflow® Ultra II with flowrates 0-25 l/min

teChniCAL DAtAGas O2, AirInlet pressure range 2,8 – 8 barMax.outlet pressure with no flow 2,1 barFlow ranges* 0 to 2 l/min 0-0,1-0,2-0,3-0,4-0,5-0,6-0, 7-0,8-1-1,5-2 0 to 6 l/min 0-0,25-0,5-0,75-1-1,5-2-2,5-3-4-5-6 0 to 25 l/min 0-1-2-3-4-5-6-7-9-12-15-25Body material nickel-plated brassControl knob polyamideO-rings EPDMFilter sintered bronze and stainless steelDiameter 39 mmLength 77 mmWeight 350 gRegulatory status Complies with Medical Devices Directive 93/42/EEC. Complies with EN 10524-4 (Pressure regulators for use with medical gases-Low pressure regulators) Complies with Standard EN 1789:2000 (Medical vehicles and their equipment-Road ambulances)

Page 27: MEDICAL CATALOGUE

25

ACCEssOrIEs - MEDIwET II hUMIDIfIEr

The bubbling humidifier for oxygen therapy is used to increase the relative humidity in the oxygen supplied to the patient in the hospital or home. The humidifiers jar are made of polycarbonate or polysulfone. The humidifiers lid are made of polypropylen. The connectors are from the brass thread and it is injected to the plastic hand nut.They can be autoclaved at a temperature of 121 °C for 20 minutes (polacarbonate) or 134°C for 18 minutes (polysulfone). Polypropylen and the silicon hose withstands 134°C. They may also be used in conjunction with GCE Mediline flowmeters and regulators providing versatility and simplicity in use.

Art. Nr. DescriptionK294401 Mediwet II 121 ºC inlet connection 9/16 UNF FK294416 Mediwet II 121 ºC inlet connection G 3/8 FK294402 Mediwet II 134 ºC inlet connection 9/16 UNF F K294432 Mediwet II 134 ºC inlet connection G 3/8 F

teChniCAL DAtAContents Only sterile waterDimensions Height 190 × Width 85 (incl hose nipple) × Ø 60 mmWeight 150 gCapacity 200 ml of waterConsumption 6 ml of water per hour at a gas flow of 10 l/min at 20 ºCMaterial Jar polycarbonate (autoclavable at 121 ºC) Jar polysulphone (autoclavable at 134 ºC) Lid and outlet hose nipple: polypropylene Inlet nut: the brass thread and it is injected to the plastic hand nut Diffuser: Polyethylene Hose: Silicone Gasket: O-ring NBROutlet connection Tapered hose nipple for hose 6 × 9 mm (recommended length 2 m)Cleaning Water, non abrasive detergent. Never use solvents.Disinfection An alcoholic solution, or other solution compatible with the material according to the disinfectant manufacturer.Autoclave Polycarbonate version 121 ºC for 20 minutes Polysulphone version 134 ºC for 18 minutesSpecial case Diffuser: exchange at every cleaning - do not sterilise!Maintenance Check that the humidifier is whole and air tight before use. Monthly exchange of gaskets is recommended. Exchange the diffuser when its microperforations no longer exist.Durability Minimum 20 autoclave cycles under the condition that all instructions accompanying the product are adhered.

sPAre PArtsArt. Nr. DescriptionK301059 Jar 121 ºCK301062 Jar 134 ºC K301078 Lid connection G3/8 K301064 Lid connection 9/16K294433 Inlet connection gasket G3/8 (10 pcs)K294407 Inlet connection gasket 9/16 UNF (10 pcs)K294408 Bottle gasket 121 ºC (10 pcs) K294409 Bottle gasket 134 ºC (10 pcs)

COnsuMABLes Art. Nr. DescriptionK294434 Complete diffuser (tube 13 cm and diffuser, 10 pcs)

Page 28: MEDICAL CATALOGUE

hOMECArE

Page 29: MEDICAL CATALOGUE

hOMECArE

Page 30: MEDICAL CATALOGUE

28

During exhalation oxygen collects in a reservoir. At the start of the inhalation, the diaphragm detects the negative pressure in the nose. This opens a valve delivering the oxygen to the patient at the start of the breath.The oxygen delivered correlates closely to the established method of constant flow across a range of breathing rates.The Sabre Elite automatically adjusts oxygen delivery on a given setting to the patient’s breathing rate. For higher breathing rates there is less time for the oxygen to collect. The patient will therefore get smaller pulses, but more of them. For lower breathing rates there is more time for the oxygen to collect. The patient will therefore get larger pulses, but less of

them.A simple way of looking at oxygen savings by considering efficiency. The % efficiency is calculated by dividing the oxygen delivered to the lung by the total flow delivered. In constant flow delivery only a small proportion of oxygen gets into the lung where it can be absorbed. About 60% to 80% of the oxygen delivered is wasted.Efficiencies are in the region of 20% to 40%.

the reAsOns FOr this Are: • Constant fl w does not stop during exhalation, so two thirds of the gas is wasted by fl wing

into the atmosphere.• Constant fl w delivers throughout inhalation including the gas that goes into the dead-space. The Sabre

Elite delivers more effici tly. Efficiencies e in the region of 90% to 70%.

The pulse of oxygen is at the start of the breath where the gas is mixed with air that goes into the lung to be absorbed.During the later part of inhalation (where the oxygen would otherwise go into dead-space) and duringexhalation the Sabre Elite saves the gas. The oxygen saving factor is primarily derived from efficiency, but other factors are relevant. The traditional constant flow settings of 2 and 4L/m are limited. By having a large range of settings with smaller increments significant further savings are possible.

The Sabre Elite has a saving factor of approximately 3 based on efficiency. If the incremental saving of having a wide range of settings that will accurately meet the patient’s need is taken into account, a saving of 3 × 1.6 = 4.8 may be claimed.

The Elite Set is supplied with a strapped carry bag Cylinder and Nasal Canulae.

CyLinDer DurAtiOn tABLeApproximate duration in hours: minutes for Elite

hOw TO sAVE OxyGEn?UsE ELITE Or ECOLITE 4000 AnD sAVE 3 Up TO 10 TIMEs ThE OxyGEn COMpArED

TO COnTInOUs fLOw

ThE nEw GCE sAbrE ELITE 8

Cylinder capacity

(litre)Pressure

(bar)Flow equivelency settings (L/min)

1 2 3 4 5

0.5 137 3:25 1:42 1:80 0:51 0:34

1.5 137 6:51 3:25 2:17 1:42 1:80

1.7 137 11:38 5:49 3:52 2:54 1:56

2.0 137 13:42 6:51 4:34 3:25 2:17

2.7 137 18:29 9:14 6:90 4:37 3:40

9.4 137 64:35 32:17 21:31 16:80 10:45

0.5 200 5:00 2:30 1:40 1:15 0:50

1.0 200 10:00 5:00 3:20 2:30 1:40

1.7 200 17:00 8:30 5:40 4:15 2:50

2.0 200 20:00 10:00 6:40 5:00 3:20

2.7 200 27:00 13:30 9:00 6:45 4:30

9.4 200 94:17 47:80 31:26 23:34 15:43

Page 31: MEDICAL CATALOGUE

29

hOMECArEELITE - pnEUMATIC GAs COnsErVEr

The Sabre Elite oxygen conserving device is an innovative way of delivering oxygen to the patient, whilst conserving the gas and extending the duration of the cylindert.

•Totally pneumatic, requires no external power source•On demand oxygen is delivered to meet patient needs, depending on exercise / effort•Matching the delivery performance of constant fl w oxygen over a range of fl w rates•All brass high pressure components•Easy to change between cylinders, medium pressure break ensures maximum user safety•Easy to use, does not require complex set up, a simple, single connection of a cannula to the therapy outlet of

the device is all that is required

GCe sABre eLite 8

Art. Nr. Description2001647 GCE Sabre Elite 8

eLite with hiGh Pressure CyLinDer COnneCtOr

Art. Nr. Description2001635 Elite valve and regulator with UK Bullnose standard connection.2001637 Elite valve and regulator with Pin Index connection.

eLite inteGrAL vALve

Art. Nr. DescriptionT.B.A. Elite valve and regulator with 17E cylinder connection.

teChniCAL DAtA Input pressure 0-200 barInlet Connector Type(s) Full range high pressurePressure gauge 0-200 bar low profileTherapy flow Equivalency (lpm) 1,0-1,2-1,5-2,0-2,5-3,0-3,5-4,0-4,5-5,0-5,5-6,0Pressure Relief Valve Pressure 7 barTherapy outlet Universal firtreeService Intervals Elite - 3 YearsNasal Canulae Part Numbers 2008202 (pack of 100)

Type of regulator Low pressure regulator without pressure gauge Outlet pressure max. 1,6

Inlet pressure 3,9 - 6 bar Therapy outlet Universal ‘fir-tree’ type.

Type of inlet connection Low pressure quick coupler connection Max. nominal gas fl w Pulse - see table below

Therapy fl w accuracy

10% for gas flows over 1l/minGas fl w setting See table below

20% for gas fl ws under 1l/min

SeTTiNg BOl u S VOl ume @ Bre ATh r ATe Per miNu Te OF

l abel elite 8 15 20 25 30

1 29 23 18 16

2 47 36 29 25

2,5 54 42 34 29

3 61 48 39 34

3,5 67 54 44 38

4 73 60 49 43

5 77 64 53 46

6 79 67 56 49

7 83 72 61 54

8 86 76 65 58

Page 32: MEDICAL CATALOGUE

30

ECOlite® 4000 Is An ELECTrOnIC OxyGEn GAs COnsErVInG DEVICE, whICh EnAbLEs pATIEnT frIEnDLy AnD EffICIEnT LOnG TErM OxyGEn ThErApy

TrEATMEnT (LTOT).

•With the ECOlite® 4000, oxygen is delivered only during the inspiration phase, permitting savings of up to 10 times compared to continuous fl w oxygen therapy

•The volume of oxygen needed for one breath is delivered during the first thi d of the inspiratory cycle, which guarantees both effici t and optimal treatment and a short exposure of the nasal mucosa to medical oxygen.

•A special feature of the ECOlite® 4000 is the small, internal regulator, that allows the user to select a supply inlet pressure of between 1,6 to 5 bar. The working pressure of the device is regulated to 1,6 bar which enables a both clinically and physiologically patient friendly oxygen administration. The device has two operating modes, Automatic and Manual

• In the Automatic mode the amount of oxygen delivered increases in relation to the set fl w rate at breath rates of 15 to 30 breaths per minute, to a maximum of 8 lpm. In the Manual mode the fl w rates are from 0,5 to 8 lpm with 0,5 lpm steps

•The fl w settings can be locked at any rate by the health care personnel in charge of setting the fl ws on initial setup

•The device has several built in alarm functions for safe use. The alarms are shown on the display and are also audible

the eCOLite® 4000 hAs ALArMs FOr: •Low battery•No oxygen•No breathing

The battery life time of the device is prolonged to last for 200 hours. Standard AA 1,5 volt batteries are in use.

OxyGEn COnsErVInG DEVICE

ECOlite® 4000

PAtenteD

0434

Page 33: MEDICAL CATALOGUE

31

1517

2024

30

12

46

8 0,05,010,015,020,025,030,035,040,045,050,055,060,065,070,075,080,085,0

Setting

Breath/min

Liter/min

Automatic mode

12468

ECOlite® 4000 OxyGEn COnsErVEr

The ECOlite 4000 is an electronic gas-conserving device with built in alarm functions. It operates with a gas cylinder set at an outlet pressure of 1.6 - 5 bar. An optional 1.6 bar outlet pressure version is available for use with a liquid oxygen container.The oxygen flows through a pressure-reducing valve before entering the ECOlite 4000 and then onto the patient via a nasal canula. The incorporated microprocessor in the ECOlite 4000 controls and manages the oxygen flow to the patient in all conditions. The sensitive valve delivers oxygen at exactly the right dosage as soon as the patient inhales, then stops. This ensures oxygen will penetrate the alveoli and be assimilated into the blood.

reGuLAtOry stAtusEuropean Economic Area (EEA): This mark on the product indicates compliance with Directive 93/42/EEC relating to medical devices, Class IIa.

Art. Nr. Description325197479 ECOlite® 4000 Conserver with spiral hose, batteries and nasal cannula

ACCessOriesArt. Nr. Descriptionmm3735 Firclic Snap On/Off Connector (to suit BAREMA standard firtree outlet)2008973 1 litre Rucksack Bag325112782 Spiral supply hose for ECOlite325112719 Belt bag

sPAre PArtsArt. Nr. Description325112670 Battery cover

teChniCAL DAtA fUnCTIOnAL pErfOrMAnCESettings Manual/Automatic Triggering At each breathSensitivity 0,13 cm H2ORegulating pressure 1,6 BarAccuracy 0,5-1,5 l/min +/- 30% 2-8 l/min +/- 15% Cycle output 0.5 to 8 l/min coresponding to 5-80 ml per bolusAlarms Battery monitoring Missing Oxygen supply No inhalation

pOwEr sUppLy Battery RO6, AA, Alkaline 1,5 VOxygen supply Pressure Between 1,6 and 5 BarFlow Minimum 4 litres per minute

DIMEnsIOns AnD wEIGhT Dimensions Height: 101 mm Width: 85 mm Depth: 32 mmWeight 184 g without battery

EnVIrOnMEnTAL COnDITIOnAmbient temperatureOperational -10°C to +40°CStorage -40°C to +70°CRelative humidity 25% to 95%

325112719

Page 34: MEDICAL CATALOGUE

32

OxyGEn COnCEnTrATOrs

InOGEn OnE® G2

The Inogen One®G2 is an oxygen system designed to provide unparalleled freedom for the active oxygen user. It’s designed for stationary, portable, and travel use, for daytime and night time, and it’s a concentrator that makes its own oxygen, so it never has to be refilled.

Art. Nr. Description14111311 Inogen One®G2 System (cannula+manual+trolley+bag+batterycharger (250V+12V)+battery)

ACCessOries/sPAre PArtsArt. Nr. Description14111312 G2 Rechargable 12 cell battery14111313 G2 Rechargable 24 cell battery14111314 G2 Recharger + power supply14111315 G2 Universal power supply14111316 G2 Carry bag14111317 G2 Caddy14111318 G2 Particle filter pu: 3 pcs14111319 G2 A/C supply cord only no pol14111320 G2 Car input cable (cig. Port)14111321 G2 Plane input cable for seat14111322 G2 Cable fuse for car cable

InOGEn OnE® G3

The new Inogen One® G3 is a smaller, lighter and makes more oxygen per kg than previous model. It is a portable concentrator light enough to be worn care-free by the active oxygen user.That means there are no tanks to refill and no worry about running out of oxygen.

Art. Nr. Description

14111361 Portable Concentrator Inogen One® G3 8 cell battery14111362 Portable Concentrator Inogen One® G3 16 cell battery

ACCessOries/sPAre PArtsArt. Nr. Description14111364 Inogen One® G3 8 cell Battery14111365 Inogen One® G3 16 cell Battery14111366 Inogen One® G3 Ext Battery Charger14111368 Inogen One® G3 DC Power Cable14111369 Inogen One® G3 Carry Bag14111370 Finger Pulse Oximeter14111371 Inogen One® G3 Particle Filters14111372 Inogen One® G3 Output Filters qt 1014111373 Inogen One® G3 Filter Spanner Wr14111374 Inogen One® G3 Filter Repl Kit

12 cell Battery 24 cell Battery Battery Charger (250V+12V)

* Included with system** Accessory sold separately

Double Lithium Ion Battery**Up to 8 hours run time

Single Lithium Ion Battery*Up to 4 hours run time

AC Power Supply*Carry Bag*

Page 35: MEDICAL CATALOGUE

33

Lockable flow control valve

Metal flow outlet fitting

Circuit breaker reset

nUVO 8 COnCEnTrATOr

FeAtures•230V / 50/60 Hz

•2.0 to 8.0 LPM fl w

•117.2 kpa (17 psi) ± 10%

•394 mm × 396 mm × 706 mm

•24.3 kg

Art. Nr. Description14111811 NUVO 8 concentrator

All products on this page require a plug adapter for use in the UK, part number 2001507.

nUVO LITE OxyGEn COnCEnTrATOr

•Lightweight - a mere 13,6 kg

•Slender and sleek cabinet design with integrated handles

•Lockable Flow Control Valve

•Litre Flow - 0,125 to 5 l/min adjustable

Art. Nr. Description14111211 Concentrator Nuvo Lite Mark 514111220 Compressor intake filter14111222 Prefiltering fleece14090329 Bacteria filter14090417 Single use bottle14090510 Cannula with 2,1 m tube

Page 36: MEDICAL CATALOGUE

EMErGEnCy EQUIpMEnT

Page 37: MEDICAL CATALOGUE

EMErGEnCy EQUIpMEnT

Page 38: MEDICAL CATALOGUE

36

DEMAnD VALVE

EAsE IIThe New Sabre EASE II portable systems provide a compact low resistance method of self-administering O2 or O2/N20. The EASE demand valve is constructed in a way that creates minimal breathing resistance to the patient and can deliver high flows when required.

For greater user comfort the EASE II is both smaller and lighter than the original Sabre EASE. The new ‘Easy Grip’ handle is another user friendly addition.

•On demand Oxygen or Nitrous Oxide/ Oxygen system for delivering up to 300 litres/ min

•Portable first stage egulator and cylinder version for immediate care and pre-hospital applications.

•Low pressure pipeline version for obstetrics and general nursing applications.

•Conforms to BS 4272: Part 2: 1996•Low inspiratory effort demand valve•Test/ Purge facility on the demand valve, easy to clean and reassemble

for cross infection protocol•Hose fit ed with probes by the national standards for connection into

cylinder system or wall outlet•Autoclavable, removable handle

The EASE II system is available to deliver Nitrous Oxide/ Oxygen upon demand. It is available for use as a portable system with first stage regulator, or as a low pressure pipeline version. The EASE is designed to administer effective pain relief within a wide range of medical situations including immediate care, general practice and general nursing obstetrics.

Conforming to BS 4272: Part 2:1996, the demand valve is designed to deliver up to 300 litres per minute of gas with minimal inspiratory effort by the patient. This valve also contains a removable patient valve that houses the exhalation flap and anti contamination valve. This can be removed and cleaned before replacement and re-use.

OPtiOnsThe Sabre EASE range of products is structured in a way to allow the user to define their personal requirements of system, cylinder and carry options.

Page 39: MEDICAL CATALOGUE

37

EMErGEnCy EQUIpMEnTDEMAnD VALVEs - EAsE II

Art. Nr. g as Type 0715302 Ease II kit with demand valve, 3 metres of hose & pin index regulator. Supplied with mask, mouthpieces and manual.0715300 EASE II Demand value with 3 metres of hose & BS5682 probe. Supplied with mask, mouthpieces and manual.0715309 EASE II kit with demand valve, 3 metres of hose and BS5682 probe, Pin Index regulator with BS5682 socket. Supplied with mask, mouthpieces and manual0715321 EASE II kit with demand valve, 3 metres of hose and BS5682 probe, For use with OXYGEN. Supplied with mask, mouthpieces and manual

teChniCAL DAtA DEMAnD VALVEGas N2O/O2 , O2

Material Polycarbonate, silicone rubber, stainless steelDimensions 50 × 50 × 63 mmWeight 0,085 kgGas supply Requirement 2,8 to 7,0 bar and 200 L/min Inspiratory resistance (At 2,8 bar supply press.) Cracking -0,15-0,2 kPa -0,2 kPa at 10 L/min -0,7 kPa at 200 L/minExpiratory resistance Cracking Zero At flow +0,35 kPa at 120 L/minOperating temperature -20°C tp +60°C used Oxygen +5°C to +40°C used 50/50 N2O/O2Storage temperature -30°C to +60°C

hOsE AssEMbLyConnection Probes by the national standardsWorking pressure 7 barBurst pressure ≥ 56 bar/23°C and ≥ 40 bar/40°CMaterial PVC, anti-static in accordance with ISO 5359Weight 0,5 kg (3 m length)

ACCessOry tO eAse iiArt. Nr. Description1032937 Disposable mouthpiece (Pack of 5 pcs)1035575P Breathing filter (Pack of 5 pcs)1032994P Disposable facemask - medium (Pack of 5 pcs)1032620P Adult size reusable mask1024417 Blue barrel carry bag 1032622P Adult/Child size mask, multiple use for Ease II 850500P Expiration diverter single use for Ease II (Pack of 1 pce)

Page 40: MEDICAL CATALOGUE

38

Manual switch-over

Gauge

Quick Couplings

Outlet

AMbULAnCE pAnEL

AMbULAnCE pAnEL IIThe Ambulance Panel ii is the next generation of ambulance panels. it is designed for permanent installa-tion and use in road ambulances. l ong experience in this market has resulted in a product that gives the customer a lot of options and flexibility.

FLexiBiLityDue to the design and functions there are a big range of variants available. The functions and variants can be combined upon customer’s request.

MODuLArThe modular concept means that same components can be used for many variants, resulting in short lead times and full fl xibility. The Ambulance Panel II is designed with same shape for recessed and exposed.

Page 41: MEDICAL CATALOGUE

39

reCesseDRecessed mounting is when the ambulance panel is mounted in the wall. The inlet could either be mounted at the end or at the back depending on the wall construction and the space behind the wall. The only part that will be outside the wall is the quick connector.

exPOseDExposed mounting is when the ambulance panel is mounted on the wall in the ambulance. The inlet could as the recessed, also be located at the end or at the back. When using the end inlet the hoses are fastened on the wall and fully visible. For some countries and regulations this is a must and the Ambulance Panel II has the features complying to these requests. The panel is fastened easily by 4 screws. Depending on the wall construction the fastening could either be done by a counter fastening frame or nuts and washers.

inLetThe inlet connection the the Ambulance Panel II is standard 3/8 thread. This is a standard thread with conical sealing that has been used many times in this kind of application. Using a threaded connection gives the assembly easier and the parts easy to maintain and exchange.

quiCk COuPLinGsThere are many variants of quick couplings on the Ambulance Panel II. The most frequent standards are used on the Ambulance Panel II. For special quick couplings please contact GCE. By using standard components and quick couplings the assembly is easy and the maintenance access able and effective.

OutLetThe outlet is standard 3/8 thread connection. If additional panels are needed, the Ambulance Panel II can have extra outlets for panels mounted in series. The panels are then connected with a standard hose and hose connections.

MAnuAL switCh-OverThe manual switch-over is a selector that chooses what cylinder is supplying the ambulance panel. There are three steps 1-0-2, where the 0 is off 1 is cylinder one and 2 cylinder two. The manual switch-over can be incorporated in the panel beside the other quick couplings or it could be mounted separately.

AMbULAnCE GAs pAnEL II

Recessed

Exposed

Inlet

Quick Couplings

Outlet

Sketch of double recessed mounted panelSketch of recessed mounted panelSketch of expossed mounted panel

Manual switch-over

GAuGeOne of the additional functions in the Ambulance Panel II is the gauge on the panel. The gauge is showing the working pressure in the system and gives continuously surveillance and is fully visible by the staff in the ambulance.

FLOwseLeCtOrThe AP II module can be equipped with a flow selector. The flow selector is permanently attached to the AP II module and can be delivered with the flow settings 0-15 and 0-25 liter per minute. This integrated module gives the AP II a compact design and minimize the products sticking out from the wall.

suCtiOnThe integrated suction ejector is a variant in the AP II system giving the end user a complete range of functions. The suction ejector uses the pressure in the system to create suction by the venture principle. The unit is operated by a simple on of button and a regulating knob to adjust the negative pressure.

AMBuLAnCe PAneL systeM (APs)The complete installation of the ambulance panel, hoses and regulators is called Ambulance Panel System.

Flowselector

Suction

Gauge

Page 42: MEDICAL CATALOGUE

40

DiMensiOns:rECCEsED MOUnTInG

441

428

79 66

28 55 70 6855

22.5

ExpOsED MOUnTInG441

7966

428

427

60.9

29

68 55 70 55 28

teChniCAL DAtA Weight example AP II O2 2xSS R: 754gQC standards BS5682Gases O2, N2O/O2

Standards EN 1789:2008Classification Class IIb

Page 43: MEDICAL CATALOGUE

41

Gss

The Automatic Gas Source Switch has been developed for devices such as transport incubators, respirators and anaesthesia devices, which can be sup-plied with gas from a cylinder during transport or whilst stationary connected to a central gas system. Economic and continuous gas supply from the central gas system will be made possible automatically and the safety of patients increased.

key BeneFits• Increased safety for users and patients•Economic gas supply from wall outlet•Less frequent replacement of gas cylinders•Compact dimensions•Simple connection to devices•A green pressure indicator indicating gas supply from gas outlet

Art. Nr. Type0727205 GSS O2 NIST0727206 GSS Air NIST0727207 GSS O2 AFNOR0727209 GSS Air AFNOR0727210 GSS O2 DIN INLET0727211 GSS Air DIN INLET

teChniCAL DAtAGases: O2, air, N20 on requestInput pressure at gas outlet 3-6 barInput pressure of pressure reducer 3.6 – 5.5 barOutput pressure = input pressureOutput flow (no internal reduction) = input flowHousing material Al-alloy, nickel platedDimensions 42x65x74 mmWeight approx. 400 gMaintenance maintenance freeMax. life 10 yearsSuitable for use in emergency in transport

Gss InLET-hOsE ATTAChMEnT From gas outlet connection NIST or AfnorFrom pressure reducer M12×1 (O2) M20×1 (Air)

Gss-OUTLET hOsE ATTAChMEnT To consumer M15×1 (O2) M17×1 (Air)

GSS automatic gas source switch switches automatically between the gas cylinder supply and wall outlet connection. Preference is always given to the more economic wall outlets. As soon as the gas socket is connected, GSS changes over from the wall cylinder to the gas outlet. It does not change over to the gas cylinder unless the pressure at the wall outlet drops below a preset minimum pressure level.

FLOw sCheMe

GSS on transport incubator

GSS on transport respirator

WALL OUTLET

DEVICEDEVICE

Page 44: MEDICAL CATALOGUE

42

rEsUsCITATIOn kITs & VEnTILATOrspOrTAfLOw & InTEGrA

The GCE Sabre Medical range of Portaflow, portable medical oxygen delivery systems include products that are equally suited for immediate care or mobile oxygen therapy. The range includes a cylinder, regulator and oxygen therapy mask. A feature of the Portaflow is that the regulator is permanently married to the cylinder, providing a user friendly, robust and low profile unit when compared with separate cylinder and regulator options. The regulator incorporates a non-return charging port and can either be refilled by reputable medical oxygen providers or, for domicillary and emergency use by decanting from larger cylinders. The integra includes a shut off isolating valve.

• Small, lightweight design• High accuracy design• Shut off, isolating valve (Integra only)• Contents gauge, fl w selector and outlet positioned in line• All brass high pressure components• Click position fl w settings• Anti rust tube and fil er• Integrated jet assembly

POrtAFLOw with CyLinDer - new white appearance cylinders complaint with UK MHRA approved changes.

pOrTAfLOw 17 (1.7 Litre)Art. Nr. Description1062598 Portaflow 17 kit with regulator flow rates 1, 2, 3, 4, 5, 6, 8, 10, 12, 15, ~23 l/min.1062622 Portaflow 17 kit with regulator flow rates 0.5, 0.8, 1, 2, 3, 4, 5, 6, 8, 10, 12, 15 l/min.

pOrTAfLOw 27 (2.7 Litre)Art. Nr. Description1062760 Portaflow 27 kit with regulator flow rates 1, 2, 3, 4, 5, 6, 8, 10, 12, 15, ~23 l/min.1062784 Portaflow 27 kit with regulator flow rates 0.5, 0.8, 1, 2, 3, 4, 5, 6, 8, 10, 12, 15 l/min.Note: Cylinder variants supplied with carry bag, mask and full to 200 bar. Fitted with a G1/4 fill port (adapters available).

pOrTAfLOw VALVE

pOrTAfLOw VALVEArt. Nr. Description1063395 Portaflow Valve regulator only with flow rates 1, 2, 3, 4, 5, 6, 8, 10, 12, 15, ~23 l/min.Note: Portaflow valve thread to cylinder is 0.715” tapered.

pOrTAfLOw ACCEssOrIEsArt. Nr. Description1032907 Oxygen mask and tubing, Adult size for Portaflow.306798P Standard nasal cannula 10 pcs2003558 Portaflow filling adaptor to 5/8“ bullnose thread.

Page 45: MEDICAL CATALOGUE

43

MArs

With Sabre MARS the operator does not have to make judgements on the lung capacity of the patient to select a tidal volume; only the basic size or type of patient being cared for. Once this simple operation has been made the MARS will control both tidal volume and pulse frequency within the parame-ters laid down in the British Standards.Even if the wrong setting is selected there is no risk of over inflating the patient’s lungs. The MARS always ‘fails safe’ and will vent excess gas whilst giving the operator an audible warning that the equipment is not being used correctly.

Art. Nr. Description1042767 MARS Standard kit with demand valve and trigger (100 l/min flow), control module

(3 settings - Adult/Medium/Child). Pin index regulator with 11 setting constant flow (1 - 23 l/min).‘Square’ carry bag, masks and head harness.

1042768 MARS Industrial kit with demand valve and trigger (100 l/min flow), control module with adult only setting.Pin index regulator with 11 setting constant flow (1 - 23 l/min).‘Square’ carry bag, mask and head harness.

1042762 MARS Bag kit with demand valve and trigger (100 l/min flow), control module(3 settings - Adult/Medium/Child). Pin index regulator with 11 setting constant flow (1 - 23 l/min).Red ‘barrel bag’, masks and head harness.

2014213 MARS AIR kit with demand valve and trigger (100 l/min flow), control module(3 settings - Adult/Medium/Child). Pin index regulator with 11 setting constant flow (1 - 23 l/min).Hard plastic case, masks and head harness.

ACCessOriesArt. Nr. Description1032620 Adult size mask, multiple use (Large) for MARS demand valve.

1024419 Barrel bag, red

nET hEAD hArnEss

Designed in partnership with UK Rescue Services, the GCE Sabre Net Head Harness is suitable for use in the harshest of rescue environments. Manufactured from heavy duty black webbing this fully adjustable harness helps keep a resuscitator mask well filled to a casually's face during extrication or during rescue from a toxic atmosphere.

Art. Nr. Description1033026 Net Head Harness

OxyGEn CyLInDErs

New white appearance cylinders compliant with uK mhr A approved changes.Art. Nr. Description1019854 Oxygen Cylinder with Pin Index Valve, 1.7 Litre, 200 bar1019797 Oxygen Cylinder with Pin Index Valve, 2.7 Litre, 200 bar1019798 Oxygen Cylinder with Pin Index Valve, 2.7 Litre, 200 bar, Empty1019799 Oxygen Cylinder with Pin Index Valve, 2.0 Litre, 200 bar

Page 46: MEDICAL CATALOGUE

44

bAGs AnD ACCEssOrIEsbAGs AnD ACCEssOrIEs

Art. Nr. Description1024417 Barrel bag, blue

1024419 Barrel bag, red

1017471 MARS hard plastic case

new POrtAFLOw ruCksACk BAGArt. Nr. Description1024401A 1.7 litre1024402A 2.7 litre (also fits BOC CD cylinder)

Page 47: MEDICAL CATALOGUE

45

MIsCELLAnEOUsMEDICAL CyLInDEr VALVEs

Art. Nr. Description0765414 Medical - Entonox - pin index 200 bar 18T (0.715 ) entonox pin 200765340 Medical - Oxygen - pin index 200 bar 17E oxy pin 200765397 Medical - Oxygen - pin index 200 bar 18T (0.715) oxy pin 200765339 Medical - Oxygen - pin index 200 bar 25E oxy pin 200775467 Medical - Oxygen - pin index 200 bar M18 oxy pin 20

Page 48: MEDICAL CATALOGUE

46

sErVICInG OpTIOns

GCe sABre MeDiCAL equiPMent serviCinG AnD rePAirFor User/Maintainer, or Service Agents, GCE offer a one day training course in-house at their works, or at GCE premises, in each of the following modules.

MEDICAL rEGULATOrs - 5 AnD 3 yEAr sErVICE AnD rEpAIr • Service schedules and instructions for the full range of GCE Sabre

Medical Gas Regulators.• Use of specified ooling and assembly equipment.• Test, troubleshooting and labeling instructions.

EAsE AnD EAsE II EnTOnOx DEMAnD VALVEs - MOnThLy ChECks AnD AnnUAL sErVICE• Service and maintenance instruction for the Regulator and Hose.• Demand Valve service, testing and troubleshooting.• A specific emand Valve Test unit is required for this training.

MArs rEsUsCITATOr - MOnThLy ChECks AnD AnnUAL sErVICE• Service and maintenance instruction for the Regulator and Hose.• Demand Valve service, testing and troubleshooting.• Control Mocule service, testing and troubleshooting.• A specific ARS Test unit is required for this training.

COUrsE ObjECTIVEs• To train course attendee(s) in the service repair and testing of GCE Sabre, Medical Regulators, MARS and EASE using the Service Manuals written for these

products (issued in CD format).• Safety considerations of medical compressed gases and the general priciples of operation of these medical devices are covered in the course, with guidance

on workplace cleanliness, tooling management and quality standards required for high pressure oxygen devices.• The training is done in a practical forum, using the GCE Sabre Medical Service Manuals, test equipments, tooling and spares kits supplied/recommended

by the manufacturer.

TrAInInG OUTCOME/bEnEfITs• Attendees of the course will be certified to Service and Repair GCE Sabre Medical products for the range specified for two years and be competent

undertake the servicing/repair activity.• User/Maintainers establish autonomy over the service and maintenance of this equipment, offering service cost savings and significa tly reduced down

time of this essential medical equipment.

ALternAtiveLy equiPMent CAn Be returneD tO GCe FOr serviCe At the ADDress BeLOw:

UsEr InsTrUCTIOnsUser instructions videos are available on the GCE website www.gcegroup.com.

GCE Latin America REGIONAL OFFICE Dakris pl. 6408 Los Ríos, Ciudad de Panamá Tel: +507 317 61 68 Fax: + 507 317 65 00

[email protected] www. gcegroup.com

Page 49: MEDICAL CATALOGUE

47

CErTIfICATEs

DNV BUSINESS ASSURANCEMANAGEMENT SYSTEM CERTIFICATE

Certificate No. 109396-2012-AQ-CZS-NA

This is to certify that the Management System of:

GCE Holding AB

Källvattengatan, SE-200 21, Malmö, Sweden

With sites as per attachment

has been found to conform to the standard:

ISO 9001:2008

This Certificate is valid for the following product or service ranges:

Design, production, sales and servicing of equipment for using of technical gases in industry. Pressure regulators, closing, combined and special valves, cutting,

welding, heating and brazing torches, safety equipment, speciality torches, fittings, accessories for industrial purposes.

Initial Certification date:28 February 1997

MSYS 002

Place and date:Høvik,9 April 2013

This Certificate is valid until:

28 February 2015

for the Accredited Unit:DET NORSKE VERITAS

CERTIFICATION AS, NORWAY

The audit has been performed under the supervision of

Evangelos Tavandžis Eugenie Winger HusebyeLead Auditor Management Representative

Lack of fulfilment of conditions as set out in the Certification Agreement may render this Certificate invalid.This Certificate has been digitally signed. See www.dnv.com/digitalsignatures for more info

HEAD OFFICE. Det Norske Veritas AS, Veritasveien 1, 1322 Hovik, Norway. Tel: +47 67 57 99 00 Fax: +47 67 57 99 11 - www.dnv.com

DNV BUSINESS ASSURANCEMANAGEMENT SYSTEM CERTIFICATE

Certificate No. 109399-2012-AQ-CZS-NA

This is to certify that the Management System of:

GCE Holding AB

Källvattengatan 9, SE-200 21, Malmö, Sweden

With sites as per attachment

has been found to conform to the standard:

NS-EN-ISO 13485:2012

This Certificate is valid for the following product or service ranges:

Design, production, sales and servicing of medical devices for using of medical gases in health service. Pressure regulators, terminal units,

suction equipment, medical hoses, cylinder and combi valves and flow meters for medical gases.

Initial Certification date:28 February 1997

MSYS 002

Place and date:Høvik, 9 April 2013

This Certificate is valid until:

28 February 2015

for the Accredited Unit:DET NORSKE VERITAS

CERTIFICATION AS, NORWAY

The audit has been performed under the supervision of

Evangelos Tavandžis Eugenie Winger HusebyeLead Auditor Management Representative

Lack of fulfilment of conditions as set out in the Certification Agreement may render this Certificate invalid.This Certificate has been digitally signed. See www.dnv.com/digitalsignatures for more info

HEAD OFFICE. Det Norske Veritas AS, Veritasveien 1, 1322 Hovik, Norway. Tel: +47 67 57 99 00 Fax: +47 67 57 99 11 - www.dnv.com

DNV BUSINESS ASSURANCEEC CERTIFICATE – FULL QUALITY ASSURANCE SYSTEM

Certificate No. 73547-2010-CE-CZS-NA 5.0

This Certificate consists of 3 pages

This is to certify that the Quality Management System of

GCE s.r.o.Žižkova 381, 583 81 Chotěboř, Czech Republic

for design, production and final product inspection/testing of

Medical Devices for use with Medical Gases

has been assessed with respect tothe conformity assessment procedure described in Article 11.3.a and Annex II excluding section 4

(Module H) of Council Directive 93/42/EEC on Medical Devices, as amended, and found to comply

Further details are given overleaf

Place and date:Høvik, 04 March 2013

This Certificate is valid until:

30 March 2015

For DET NORSKE VERITAS CERTIFICATION ASNORWAY

Eugenie Winger Husebye Notified Body No.: 0434

Aud Løken EiklidCertification Manager Technical Reviewer

This Certificate has been digitally signed. See www.dnv.com/digitalsignatures for more info

Notice: The certificate is subject to terms and conditions overleaf. Any significant changes in design or construction may render this certificate invalid.If any person suffers loss or damage which is proved to have been caused by any negligent act or omission of Det Norske Veritas, then Det Norske Veritas shall pay compensation to such person for his proved direct loss or damage. However, the compensation shall not exceed an amount equal to ten times the fee charged for the service in question, provided that the maximum compensation shall never exceed USD 300.000. In this provision “Det Norske Veritas” shall mean the Foundation Det Norske Veritas as well as all its subsidiaries, directors, officers, employees, agents and any other acting on behalf of Det Norske Veritas.

Det Norske Veritas Certification AS, Veritasveien 1, 1322 Høvik, Norway. Tel: +47 67 57 9900 Fax: +47 6757 9911 www.dnv.comPage 1 of 3

Page 50: MEDICAL CATALOGUE

Art

. Nr.

CATM

EDU

K021

4. E

ditio

n 4/

2014

. Alte

ratio

ns a

re s

ubje

ct to

cha

nge

with

out n

otic

e. 0

7032

014h

z ©

GCE

201

4

GCE Group is one of the world’s leading companies in the field of gas control equipment. The headquarters are inMalmö, Sweden, and the two major supply units are located in Europe and Asia.The company operates 15 subsidiaries around the world and employs more than 850 people. GCE Group includesfour business areas – Cutting & Welding, Process Applications, Medical and High Purity.Today’s product portfolio corresponds to a large variety of applications, from single pressure regulators andblowpipes for cutting and welding to sophisticated gas supply systems for medical and electronics industry applications.

[email protected]. gcegroup.com

GCE Latín America OFICINA REGIONAL Po. Box: 0843-01211

Dakris pl. 6408 Los Ríos, Ciudad de Panamá Tel: +507 317 61 68

Fax: + 507 317 65 00