mbcx-3clu - stw...subect to change without notice data sheet mbcx-3clu | bcx body control units |...
TRANSCRIPT
Data sheet mBCX-3CLU | BCX body control units | 20190619-87020 Page 1 | 14Subject to change without notice
mBCX-3CLUBCX body control units
KEY FEATURES• Modular construction kit based on a mechanical
platform and a generic control platform
• Flexible programming in C and CODESYS IEC61131
• Compliance with standards for the automotive, agricultural and construction machinery industries
• Error Diagnostics
• Monitoring of relays, fuses and consumers in the on-board network
• Less wiring effort
TECHNICAL DATA• TriCore TC 1798 32bit, 300MHz
• 288 kB SRAM internal
• 8 MB SDRAM external
• 4 MB Flash
• 32 kB EEPROM
• 4 CAN interfaces, 1 RS232 interface and 1 Ethernet interface
• 36 inputs
• 74 outputs
ACCESSORIES • Mating connector
• Break out Box
• Starter Kit
• Compiler Package
• C-Software CD
• IEC 61131-3 Package V3.x
• Step-files
• Manual
Sensor-Technik Wiedemann GmbH
Am Bärenwald 6 87600 Kaufbeuren
+49 8341 9505-0 [email protected]
www.stw-mm.com
Data sheet mBCX-3CLU | BCX body control units | 20190619-87020 Page 2 | 14Subject to change without notice
BLOCK DIAGRAM
BtsXX_Highside01:1 x OD10A Output
1 x Door Contact Wake-up InputInXX_Door01
Controller System
TriCore32 bit, 300 Mhz
SRAM 288 kB intern
SDRAM 8 MB extern
Flash 4 MB intern
EEPROM 32 kB
RS232 CAN 1Wake-up
CAN 2 CAN 4RS485*
ETH 1Ethernet
Switch on (Ignition)
System Supervisor with Watchdog
„Power ON“ LED
8 x IACV Input
8 x IDA5V Input
12 x IDA35V Input
Main Switch 1
*this interfaces share the same IO-pins, either CAN 3 or RS485 can be used
FuseXX_Out01: Internal Voltage Supply 8 V … 32 V
5 X
Controller System
CAN 3(CANopen)3 x High Side Wake-up Input
InXX_Highside01
4 x High and Low Side InputInXX_HighLow01
X1Power Bolt(KL30)
FuseXX_InOut01: Socket for Car Fuse, up to 15 A
5 X
Vehicle Battery (12 V / 24 V System)
FuseXX_Out01: Socket for Car Fuse, up to 25 A
4 X
FuseXX_Out01:Socket for Car Fuse, up to 15 A
7 X
FuseXX_Out01:Socket for Car Fuse, up to 10 A
8 X
FuseXX_Out01:Socket for Car Fuse, up to 5 A
3 X
8 x OP2A Output
8 x OP2A Output
4 x OP4A Output
8 x OD2A Output
Extra Low Voltage (8 V … 32 V)
Main Switch 2
Main Switch 3
Main Switch 4
RelXX_Can9Pol01: Socket for Mini Relais,
for up to 25 A 5 PinsOptional, Special Relay, 9 Pins
1 X
BtsXX_HalfBridge01:2 x OD10A Output
Brake Function
RelXX_Can9Pol01:Socket for Mini Relais, for up to 15 A, 5 Pins,
2 X
User LED
RelXX_normOpen02: Output for Mini Relais Socket, 2 times secured, 2 x Car Fuse up to 20 A, 5 Pins
RelXX_normOpen02: Output for Mini Relais Socket, 2 times secured, 2 x Car Fuse up to 15 A, 5 Pins
RelXX_normOpen01: Output for Micro Relais Socket, 1 times secured,Car Fuse up to 25 A, 5 Pins
RelXX_normOpen01:OutputforMicroRelaisSocket,1 timessecured,Car Fuse up to 15 A, 5 Pins
1 X
3 X
2 X
2 XBtsXX_Highside01:
1 x OD5A Output
BtsXX_Highside01: 1 x OD5A Output for
External Supply Fuse
FuseXX_Out02: Sensor Supply Voltage 5 V
FuseXX_Out02: Sensor Supply Voltage 5 … 12 V
Legend Tabel:
Power Supply Line without Fuse Power Supply Line with Fuse
Line for Communication Interfaces Control Line or Input LineControl and Diagnostic LineDiagnostic Line
Supply Line for Extra Low Voltage without Fuse Optional, Special Relay, 9 Pins
Data sheet mBCX-3CLU | BCX body control units | 20190619-87020 Page 3 | 14Subject to change without notice
System Data
Type Property Values
Supply Voltage Direct Current (DC) 8 … 32 V
Power Consumption Without external load < 400 mA at 12 V supply voltage< 240 mA at 24 V supply voltage
Standby (ignition off) < 1 mA
Maximum load current 60 A
Temperature Chassis Temperature −40 °C … +85 °C−40 °F … +185 °F
Connector Automotive Type (Tyco / AMP):Ethernet-Variant:
81 Pins4-pin M12 sleeve with D-Code
Indicators 2 LED 1 x for system status and 1 x freely programmable
Housing Die-cast aluminum GORE-TEX® Membrane for pressure equalization
Dimensions Standard VariantVariant with Ethernet-con-nector
217 mm x 138 mm x 51 mm217 mm x 152,5 mm x 51 mm
Weight Ca. 1.3 kg (2.9 lbs)
Degree of Protection IP6k7 and IP6k9k without Ethernet-connector
IP6k7 with Ethernet-connector
Certificates and Compliance
Qualified to the applicable standards for automotive, agricultural and construction industries
CE
RoHS
E1: All vehicle types with a 12 V resp. 24 V – electrical wiring and battery (−) at the body.
Processor and memory
Type Properties Features
TriCore TC1798 32 bit, 300 MHz Optional: Separate system supervisor with programmable watchdog
SRAM 288 kB internal
SDRAM 8 MB external Available space for customer application (non-safety): in C: 7,80 MB in CODESYS: 3,00 MB
Flash 4 MB internal Available space for customer application (non-safety): in C: 3,75 MB in CODESYS: 2,00 MB
EEPROM 32 kB Available space for customer application (non-safety): in C: 24 kB in CODESYS: 24 kB
Communication Interfaces
Type Max. Quantity Configuration
CAN 4 CAN 2.0 B, Low-/High-Speed max 1 Mbit/s
CAN 1: Wake-up functionality
CAN 4: CAN or configurable as RS 485, half-duplex, baud rate up to 115 kbit/s
RS 232 1 baud rate up to 115 kbit/s
Ethernet 1 Hardware-variant with additional connector. Speed up to 100 Mbit/s
TECHNICAL DATA
Data sheet mBCX-3CLU | BCX body control units | 20190619-87020 Page 4 | 14Subject to change without notice
Outputs (All outputs are short circuit protected)
Type Max. Quan-tity
Configuration Range Property
Sensor Supply UExt
3 Programmable 5 … 12 V 100 … 250 mA
Fixed Voltage 8,5 V Max. Current 250 mA
Fixed Voltage 5 V
Interfaces
Type Fuses Max. Quantity
range attributes
Fuse pro-tection ext. voltages
1 5 V 250 mA Fuse protection on GND
Fuse pro-tection ext. voltages
1 5 … 12 Vmax 250 mA
Fuse protection on GND
Fuses 3 5A Power supply via power bolt with diagnostic function
Fuses 8 10A Power supply via power bolt with diagnostic function
Fuses 7 15A Power supply via power bolt with diagnostic function
Fuses 4 25A Power supply via power bolt with diagnostic function
Fuses 5 15 A External power supply with diagnostic function
Interfaces
Type Semi-conductor outputs
Max. QuantityConfigura-tion
Values Features Property
Half bridge protected
2 Digital 0 … 10 A Current On/Off
Power supply via power boltHalf bridge with brake functionprotected by fuse
High Side 1 Digital 0 … 10 A Current On/Off
Power supply via power boltprotected by fuse, with diagnostic function
High Side 1 Digital 0 … 5 A Current On/Off
Power supply via power boltprotected by fuse, with diagnostic function
High Side 1 Digital 0 … 5 A Current On/Off
Power supply via power boltprotected by fuse, with diagnostic functionexternal power supply (8…32 V)
TECHNICAL DATA
Data sheet mBCX-3CLU | BCX body control units | 20190619-87020 Page 5 | 14Subject to change without notice
Interfaces
Type Relay outputs
Max. Quantity
Pins range protection attributes
Micro Relay 2 5 0 … 15 A 1 Power supply via power bolt with diagnostic functioninternal control by processor
Micro Relay 2 5 0 … 25 A 1 Power supply via power bolt with diagnostic functioninternal control by processor
Mini Relay 3 5 0 … 15 A 2 Power supply via power bolt with diagnostic functioninternal control by processor
Mini Relay 1 5 0 … 20 A 2 Power supply via power bolt with diagnostic functioninternal control by processor
Mini Relay 1 9 0 … 25 A -- external power supply external triggering no diagnostic functionCAN interface for extensions
Mini Relay 2 9 0 … 15 A -- external power supply external triggering no diagnostic functionCAN interface for extensions
System Information
Type Property Values
supply voltage DC voltage 8 … 32 V
current consumption without ext. load < 400 mA bei 12V supply
< 240 mA bei 24V supply
Standby (Ignition off) < 2 mA
Maximaler Laststrom 210 A
temperature range Chassis temperature −40 °C ... +85 °C
-40 °F … + 185 °F
displays 2 LED 1 x for system status and 1 x freely programmable
housing Aluminium die casting
weight 1,6 Kg
Connectors
Type Quantity Pins
JPT 5 21
JPT 2 18
DFK 1 12
TECHNICAL DATA
Data sheet mBCX-3CLU | BCX body control units | 20190619-87020 Page 6 | 14Subject to change without notice
TECHNICAL DRAWING
4x 7,5 +-
0,80,5
0
248
+ -0,5
0,3
6,5 19 229
241,
5
0
191 +-
0,50,3
19
184,5
Power ON LED
User LED1
0,5
262 ±1,5
40
+ -1,2
1,4
78,
4 ±2
Connector optional
Data sheet mBCX-3CLU | BCX body control units | 20190619-87020 Page 7 | 14Subject to change without notice
PIN ASSIGNMENT mBCX.3cluConnector X1: Power Bolt
Data sheet mBCX-3CLU | BCX body control units | 20190619-87020 Page 8 | 14Subject to change without notice
X3 Pin
Connected component
Additional description of functionality
Connected fuse
Connected relay
Supplied from
1 Rel25_Can9Pol01_02 K5 KL87a
2 Rel25_Can9Pol01_02 K5 C
3 OD2A_1 Output of controller
4 Rel30_normOpen02_02 F32 K3 X1
5 IACV_2 Input of controller
6 OD2A_2 Output of controller
7 Rel30_normOpen02_03 F33 K4 X1
8 IDA35V_12 Input of controller
9 IACV_3 Input of controller
10 Fuse10_Out01_07 F7 X1
11 IDA35V_10 Input of controller
12 IACV_1 Input of controller
13 Rel25_Can9Pol01_02 K5 KL86
14 IDA5V_3 Input of controller
15 IDA35V_11 Input of controller
16 Rel15_normOpen01_02 F35 K11 X1
17 5Vext 5Vext external sensor
supply output of control-
ler
18 OD2A_3 Output of controller
19 Rel25_Can9Pol01_02 K5 X
20 Fuse02_Out02_01 AGND of 5Vext of the
ESX-3CM
F42
21 OD2A_4 Output of controller
PIN ASSIGNMENT mBCX-3CLUPin assignment of connector X2 (green) sorted by pin numbers Pin assignment of connector X3 (magenta) sorted by pin numbers
X2 Pin
Connected component
Additional description of functionality
Connected fuse
Connected relay
Supplied from
1 Fuse05_Out01_03 F25 X1
2 Fuse10_Out01_02 F10 X1
3 Fuse10_Out01_01 F8 X1
4 Fuse15_Out01_06 F1 X1
5 IDA35V_7 Input of controller
6 OP2A_14 Output of controller
7 Fuse05_Out01_02 F2 X1
8 IDA35V_8 Input of controller
9 IDA35V_9 Input of controller
10 Fuse05_Out01_01 F4 X1
11 IDA35V_4 Input of controller
12 IDA35V_5 Input of controller
13 Rel30_normOpen02_01 F27 K2 X1
14 IDA35V_6 Input of controller
15 IDA35V_3 Input of controller
16 Rel30_normOpen02_01 F28 K2 X1
17 CAN4_H or RS485_A CAN bus or serial inter-
face of controller
18 CAN4_H or RS485_A CAN bus or serial inter-
face of controller
19 OP2A_16 Output of controller
20 CAN4_L or RS485_B CAN bus or serial inter-
face of controller
21 CAN4_L or RS485_B CAN bus or serial inter-
face of controller
Data sheet mBCX-3CLU | BCX body control units | 20190619-87020 Page 9 | 14Subject to change without notice
X4 Pin
Connected component
Additional description of functionality
Connected fuse
Connected relay
Supplied from
1 Fuse15_Out01_07 F11 X1
2 OP2A_2 Output of controller
3 In35_HighLow01_01 Input of controller
4 Fuse15_Out01_03 F39 X1
5 CAN2_L CAN bus of controller
6 CAN2_L CAN bus of controller
7 Fuse15_InOut01_03 External voltage supply in F41
8 CAN2_H CAN bus of controller
9 CAN2_H CAN bus of controller
10 Fuse15_InOut01_03 External voltage supply
out
F41
11 GND
12 OP2A_8 Output of controller
13 Rel15_Can9Pol01_01 K6 C
14 Rel15_Can9Pol01_01 K6 KL30
15 OP2A_1 Output of controller
16 Bts08_HalfBridge01_02 F47 Internal (K13) X1
17 Bts08_HalfBridge01_01 F45 Internal (K12) X1
18 IDA35V_2 Input of controller
PIN ASSIGNMENT mBCX-3CLUPin assignment of connector X4 (white) sorted by pin numbers
X5 Pin
Connected component
Additional description of functionality
Connected fuse
Connected relay
Supplied from
1 Fuse15_InOut01_01 External voltage supply in F29
2 Fuse15_Out01_05 F9 X1
3 In35_Highside01_01 Input of controller
4 Fuse15_InOut01_01 External voltage supply
out
F29
5 GND
6 OP2A_5 Output of controller
7 RS232_TxD Serial interface
8 RS232_RxD Serial interface
9 OP2A_6 Output of controller
10 Fuse15_InOut01_02 External voltage supply
out
F36
11 CAN1_H CAN bus
12 CAN1_H CAN bus
13 Rel30_normOpen02_03 F34 K4 X1
14 CAN1_L CAN bus
15 CAN1_L CAN bus
16 Rel30_normOpen02_02 F31 K3 X1
17 IDA5V_6 Input of controller
18 OP2A_7 Output of controller
19 Rel15_normOpen01_01 F30 K10 X1
20 IDA35V_1 Input of controller
21 In35_HighLow01_02 Input of controller
Pin assignment of connector X5 (blue) sorted by pin numbers
Data sheet mBCX-3CLU | BCX body control units | 20190619-87020 Page 10 | 14Subject to change without notice
X6 Pin
Connected component
Additional description of functionality
Connected fuse
Connected relay
Supplied from
1 In35_Door01_01 Input of controller
2 In35_Highside01_02 Input of controller X1
3 In35_Highside01_03 Input of controller
4 In35_HighLow01_04 Input of controller
5 OP2A_15 Output of controller
6 In35_HighLow01_03 Input of controller
7 Rel15_Can9Pol01_01 K6 KL87
8 Rel15_Can9Pol01_01 K6 KL87a
9 OP2A_13 Output of controller
10 Rel15_Can9Pol01_01 K6 X
11 Rel25_Can9Pol01_01 K7 C
12 IDA5V_4 Input of controller
13 OP2A_9 Output of controller X1
14 Rel25_Can9Pol01_01 K7 X
15 OP2A_11 Output of controller
16 Rel15_Can9Pol01_01 K6 KL86 X1
17 Rel25_Can9Pol01_01 K7 KL87a
18 OP2A_12 Output of controller
19 Rel25_Can9Pol01_01 K7 KL86 X1
20 Fuse15_InOut01_02 External voltage supply in F36
21 OP2A_10 Output of controller K7 KL86 X1
PIN ASSIGNMENT mBCX-3CLUPin assignment of connector X6 (yellow) sorted by pin numbers
X7 Pin
Connected component
Additional description of functionality
Connected fuse
Connected relay
Supplied from
1 Fuse15_InOut01_04 External voltage supply
out
F37
2 Fuse15_InOut01_04 External voltage supply in F37 X1
3 OD2A_7 Output of controller
4 Fuse15_Out01_01 F38 X1
5 IACV_4 Input of controller
6 GND
7 Fuse15_Out01_04 F40 X1
8 OD2A_8 Output of controller
9 OD2A_6 Output of controller
10 Fuse15_InOut01_05 External voltage supply in F43
11 IDA5V_1 Input of controller
12 IDA5V_2 Input of controller
13 Fuse15_InOut01_05 External voltage supply
out
F43 X1
14 IACV_7 Input of controller
15 IACV_8 Input of controller
16 Fuse10_Out01_03 F16 X1 X1
17 IACV_6 Input of controller
18 OP4A_2 Output of controller
19 OP4A_1 Output of controller X1
20 OD2A_5 Output of controller
21 IACV_5 Input of controller
Pin assignment of connector X7 (brown) sorted by pin numbers
Data sheet mBCX-3CLU | BCX body control units | 20190619-87020 Page 11 | 14Subject to change without notice
X8 Pin
Connected component
Additional description of functionality
Connected fuse
Connected relay
Supplied from
1 Bts10_Highside01_01 F49 Internal (K14) X1
2 Fuse10_Out01_08 F17 X1
3 OP2A_3 Output of controller
4 Fuse15_Out01_02 F18 X1
5 IDA5V_5 Input of controller
6 Fuse02_Out02_02 AGND of 5-12Vext of the
controller
F46
7 Fuse10_Out01_04 F20 X1
8 Fuse10_Out01_05 F48 X1
9 5-12Vext 5-12Vext external sensor
supply output of control-
ler
10 Fuse10_Out01_06 F21 X1
11 IDA5V_8 Input of controller
12 OP4A_3 Output of controller
13 Bts05_Highside01_01 External voltage supply in F44 Internal (K15)
14 IDA5V_7 Input of controller
15 OP4A_4 Output of controller
16 Bts05_Highside01_02 F50 Internal (K16) X1
17 Bts05_Highside01_01 External voltage supply
out
F44 Internal (K15)
18 OP2A_4 Output of controller
PIN ASSIGNMENT mBCX-3CLUPin assignment of connector X8 (grey) sorted by pin numbers
X9 Pin
Connected component
Additional description of functionality
Connected fuse
Connected relay
Supplied from
1 Rel25_normOpen01_01 F22 K8 X1 X1
2 Rel40_normOpen02_01 F24 K1 X1 X1
3 Rel40_normOpen02_01 F23 K1 X1
4 Rel25_normOpen01_02 F26 K9 X1 X1
5 Fuse25_Out01_01 F5 X1
6 Fuse25_Out01_02 F3 X1
7 Fuse25_Out01_04 F12 X1 X1
8 Fuse25_Out01_03 F6 X1 X1
9 Rel25_Can9Pol01_02 K5 KL30
10 Rel25_Can9Pol01_02 K5 KL87 X1
11 Rel25_Can9Pol01_01 K7 KL30
12 Rel25_Can9Pol01_01 K7 KL87
Pin assignment of connector X9 (black) sorted by pin numbers
Data sheet mBCX-3CLU | BCX body control units | 20190619-87020 Page 12 | 14Subject to change without notice
EMC industrial (CE)
Emissions (Residential, commercial and light-industrial envirnoments
DIN EN 61000-6-3
Immunity for industrial environments - Electrostatic discharge immunity test
DIN EN 61000-6-2
Immunity for industrial environments - Radiated, ra-dio-frequency, electromagnetic field immunity test
DIN EN 61000-6-2
Immunity for industrial environments - Burst (Electrical fast transient / burst immunity test)
DIN EN 61000-6-2
Immunity for industrial environments - Surge immunity test
DIN EN 61000-6-2
Immunity for industrial environments - Conducted immunity(Immunity to conducted disturbances, induced by radio-frequency fields)
DIN EN 61000-6-2
Immunity for residential, commercial and light-industri-al environments
DIN EN 61000-6-1
Emission standard for industrial environments DIN EN 61000-6-4
EMC automotive
Radiated emissions from components - ALSE method (emissions antenna) (RE Test)
ECE R10(CISPR25, DIN EN 55025)
Radiated immunity ECE R10(ISO 11452-5/-2)
Voltage transient emissions test (CTE Test) ECE R10ISO 7637-2
Electrical transient conduction alongPulse 1 (12V) - 150V, 5000 pulses, 10ΩPulse 1 (24V) - 600V, 5000 pulses, 50ΩPulse 2a (12V + 24V) 112V, 5000 pulses, 2ΩPulse 2b (24V), 20V, 10 pulsesPulse 3a (12V + 24V), -300V, 1hrPulse 3b (12V + 24V), +300V, 1hrPulse 4 (12V), -7V, 2 pulsesPulse 4 (24V), -16V, 2 pulses
ECE R10ISO 7637-2
Discontinuities in supply voltage - Load dumpPulse 5a (12V + 24V) 123V, 100 ms, 4 Ω, 2 pulsesPulse 5b (24V)
ISO 16750-2(ehem. ISO 7637-2)
Road vehicles - Electrical disturbances from conduc-tion and coupling - Part 3: Electrical transient trans-mission by capacitive and inductive coupling via lines other than supply lines(TOL Test)
ISO 7637-3
Conducted emission; power and signal lines CISPR25
ESD - Component immunity test method ISO 10605
ESD - Packaging and handling ISO 10605
DETAILED QUALIFICATIONS
Data sheet mBCX-3CLU | BCX body control units | 20190619-87020 Page 13 | 14Subject to change without notice
Electrical tests
Safety of machinery - Electrical equipment of machines - Part 1: General requirements
DIN EN 60204-1
Supply voltage STW Company Standard(Art.Nr. 26688)
Overvoltage / Undervoltage /Switch-on hysteresis
STW Company Standard(Art.Nr. 26688)
Cable breakage supply lines STW Company Standard(Art.Nr. 26688)
Short circuit strength of signal andcommunication lines
STW Company Standard(Art.Nr. 26688)
Start test STW Company Standard(Art.Nr. 26688)
Polarity protection STW Company Standard(Art.Nr. 26688
Data retention STW Company Standard(Art.Nr. 26688)
Load test STW Company Standard(Art.Nr. 26688)
Start-processing times STW Company Standard(Art.Nr. 26688
Direct current supply voltage ISO 16750-2
Overvoltage - Systems with 12V / 24V nominal voltage ISO 16750-2
Superimposed alternating voltage ISO 16750-2
Slow decrease and increase of supply voltage ISO 16750-2
Discontinuities in supply voltage -Momentary drop in supply voltage
ISO 16750-2
Discontinuities in supply voltage -Reset behavior voltage drop
ISO 16750-2
Electrical tests
Discontinuities in supply voltage -Starting profile 12V code B (8-32V)Voltage cranking; Level 1Voltage cranking; Level 2Voltage cranking; Level 3Voltage cranking; Level 4
ISO 16750-2
Discontinuities in supply voltage -Starting profile 24V code ? (8-32V)Voltage cranking; Level 1Voltage cranking; Level 2Voltage cranking; Level 3
ISO 16750-2
Reversed voltage - Case 2 ISO 16750-2
Ground reference and supply offset ISO 16750-2
Open circuit tests - Single line interruption ISO 16750-2
Open circuit tests - Multiple line interruption ISO 16750-2
Short circuit protection - signal circuits ISO 16750-2
Short circuit protection - load circuits (supply lines) ISO 16750-2
Withstand voltage ISO 16750-2
Insulation resistance ISO 16750-2
DETAILED QUALIFICATIONS
Data sheet mBCX-3CLU | BCX body control units | 20190619-87020 Page 14 | 14Subject to change without notice
Climatic and mechanical tests
PSD Vibration noise with temperature superimposition / Test VII (Power Spectral Density)
ISO 16750-3
PSD Vibration noise with temperature superimposition, Ad-ditional profile in the case of DUT natural frequencies < 30 Hz (Test VII)
ISO 16750-3
Mechanical Shock - Test for devices on rigid points on the body and on the frame
ISO 16750-3
Free fall ISO 16750-3
Vibration (sinusoidal) DIN EN 60068-2-6
Shock DIN EN 60068-2-27
Bump DIN EN 60068-2-27
Tests at constant temperature: Low temperature - storage ISO 16750-4
Tests at constant temperature: Low temperature – operation ISO 16750-4
Tests at constant temperature: High temperature – storage ISO 16750-4
Tests at constant temperature: High temperature – operation ISO 16750-4
Temperature step test ISO 16750-4
Temperature cycling test ISO 16750-4
Temperature cycling test - Rapid change of Temperature ISO 16750-4
Corrosion test with flow of mixed gas ISO 16750-4
IP Protection IP30 ISO 20653
Life-time (Temperature cycling test - Rapid change of Tem-perature)
ISO 16750-1 Annex B
Life-time STW WN (26688)
DETAILED QUALIFICATIONS