master distributor of intelligent motor controller starters is looking for investor
DESCRIPTION
The product caters for a number of industrial sectors where electricity is being wasted. Fixed speed AC induction motor can benefit by utilizing the product as a soft starter and as well as device for energy conservation & optimization, which can easily be achieved, where the motor are loaded and unloaded during the work cycle and operation.TRANSCRIPT
Master Distributor of Intelligent Motor Controller Starters Is Looking for Investor
This presentation was kindly prepared by the project owner for www.merar.com
POWERBOSS
THE INTELLIGENT CHOICEFOR FIXED SPEED MOTOR
CONTROL
PROBLEMS WITH MOTORS
HIGH STARTING CURRENT PROBLEMS
CurrentDirect On Line
Mot
or C
urr
ent
Speed
In
6-12 x In
100% N
Excess Starting Current
PROBLEMS WITH MOTORS
HIGH STARTING CURRENT PROBLEMSHigh Torque
Torque
Direct On Line
100% N
X N
omin
al M
otor
Tor
qu
e
Speed
2.5
1 Excess Starting Torque
Acceleration Torque
Load Torque
DOL Torque
† Star Delta Current
Speed 100% N
Transition Peakup to 20 x In
Excess StartingCurrent
Mot
or C
urr
ent
6-10 x In
In
3X In
Star Delta Torque
X N
omin
al M
otor
T
orq
ue
Speed 100% N
2.5
1
Excess Acceleration Torque
0.33
Delta Torque
Star Torque
Load Torque
Powerboss vs DOL
Mot
or C
urre
nt
Speed 100% N
6-10 x In
Direct on Line Current
1
Unused Starting Current
Powerboss Start
Powerboss vs DOL
TorqueX
Nom
inal
Mot
or
Tor
que
2.5
0.66
1
Unused Starting Torque
Motor Torque
Speed 100% N
Load Torque
Powerboss Torque
Acceleration Torque
SEE THE DIFFERENCE
Direct on Line Powerboss
PROBLEMS WITH MOTORS
HIGH STARTING CURRENT PROBLEMS High Torque VOLTAGE DIPS HIGH ENERGY COST NUISANCE TRIPPING
"NUISANCE TRIPPING"
A nuisance trip occurs when it mistakes a normal operating condition for a hazardous condition,
Also, it is a nuisance to constantly have to reset a defective circuit breaker. However, it may not be defective, it may be a warning that the wiring and its connections are being overloaded with too much current or too many appliances.
Never try to solve the problem of a nuisance tripping circuit breaker by putting in a higher rated breaker; i.e., a 30 amp breaker in place of a 15 or 20 amp breaker.
PROBLEMS WITH MOTORS
HIGH STARTING CURRENT PROBLEMS High Torque VOLTAGE DIPS HIGH ENERGY COST NUISANCE TRIPPING EXCESSIVE WEAR & TEAR OF EQUIPMENT
Motor Losses
PROBLEMS WITH MOTORS
HIGH STARTING CURRENT PROBLEMS High Torque VOLTAGE DIPS HIGH ENERGY COST NUISANCE TRIPPING EXCESSIVE WEAR & TEAR OF EQUIPMENT FREQUENT CONTACTOR REPLACEMENT CO2 EMISSIONS
Real Power kWCos
Reactive Power kvar
Apparent Power
VA
How Powerboss Works
How Powerboss Works
Torque is proportional to the applied voltage squared: T∞V²
The Powerboss adjusts the output voltage to the motor according to the torque required
This in turn decreases the current.Voltage and current are common to all three
sides of the power triangle
How Powerboss Works
The Power triangle is reduced from all three sides saving energy in three components:
Kva which is the total energy applied which will put less strain on the supply as less current is drawn.
Kw which is paid for.Kvar the reactive component causing heating
and vibration in the motor (all the nastiness).
Powerboss is not designed to increase the PF significantly
If you look at the power triangle the lagging angle is only decreased by a small amount even although there is a significant drop in Kvar. The reason for this is the triangle is affected from all three sides.
Real Power kWCos
Reactive Power kvar
Apparent Power
VA
How Powerboss Works
Recap
If you look at a capacitor it affects Kvar only so it changes the triangle differently see below;
Power Factor correction is designed to counter act the KvarL in the system thus only improves the PF and reduces LPF penalty
Real Power kW
Cos
Apparent Power
VA
Reactive PowerKVAR
USING POWERBOSS AS A SOFT STARTER YOU CAN:
Prevent dips in supply when starting larger motors
Attach more equipment to a single supplySwitch your motors On & Off at any time due
to reduced starting currentSignificantly increase the life of contactors &
drive train componentsReduce the worry of Peak Demand penalties
during starting
EFFICIENT RUNNING withPOWERBOSS INTEGRA
Motors consume only the energy required by the load
Optimisation of Voltage automatically Motors are switched off automatically
when idlingEnergy cost reducedReduced heat and vibrationReduced breakdowns
SMOOTH STARTINGControlled starting currentControlled starting torqueControl on Max Demand
POWERBOSS is in effect an electronic clutch ensuring gradual uptake of power, smooth step-less acceleration and reduced stress on driven equipment
CONTROLLED STOPPINGPowerboss Soft Stop controls decelerationMinimises ‘water hammer’ effectReduces damage to pipe systemsProvides energy efficient plug braking for stored
energy
POWERBOSS-General features
Soft StartOptional DOL startCurrent LimitKick StartSoft StopPlug BrakingEnergy Saving
POWERBOSS- Special Features
Timed Cut offStored EnergyArc-less SwitchingControlled Star-Delta
WHERE SHOULD YOU USE
POWERBOSS ? Injection moulding machines Power Presses & Die Castings Rubber Industry Rock & Aggregate Crushers Water pumps & Compressors Conveyors Fly-Wheel applications Fans & Blowers Ice Plants Agitators , Mixers & Marble Industry
SOME POWERBOSS CLIENTELE
3M Ford Motor Co. Renault Nissan Volvo Penta Aston Martin Proton Cars Honda
Parker Pen Co. Denso Procter & Gamble Coca Cola Cadbury Schweppes Johnson Controls TRW Damage
Powerboss is installed in over 77 countries around the world
CLIENTELE IN PAKISTAN
Samad Rubber Works
Sufi Steel Mills Sazgar Ltd Margla Stone
Crusher Kashif Crushers Awais Flour Mills
Service Industries (Tyre Department)
Al-Qamar Steel Nauras Ltd Pak Chemicals Ltd QadBros Meraj Industries 12 x CNG Stations
Positive Audit for over 85 companies have been
conducted
Energy Readings Logged without Powerboss
Max = 11.826 kWh
Energy readings logged with Powerboss
Max = 8.969 kWh 24% Saving
Max Apparent power without Powerboss
Actual = 32451(VA)
Max Apparent power with Powerboss
Actual = 8487(VA)