Page 1: MASSAGE BATHTUB

MODEL : SYM085A

INSTALLATION INSTRUCTION

MASSAGE BATHTUBMASSAGE BATHTUB

Page 2: MASSAGE BATHTUB

1、pillow

2、handrail

3、water jet

4、water in

5、switch

6、cold/hot water switch

7、drainage switch

10 9 8

126543 21

711

14

8、drainage

9、shower

10、tap

11、air conditioning

12、control panel

13、

、Backflow prevention

air bubble jet

14 bottom light

15

Shower

Shower chain

1

13

Sketch

15

Page 3: MASSAGE BATHTUB

650

2

Manual

Earth line

Red pipehot water pipe

blue pipecold water pipe

230

9201840

12

40

SIZE:1840 ×1240×650mm

Cold water pipe

Hot water pipeSocket

Earth line

Page 4: MASSAGE BATHTUB

Cautions

3

I、Safety

Danger symbol:This icon reminds the users that this product has dangerous voltage!

Warning symbol:This icon reminds the users that this product is enclosed with importantoperating and maintenance instruction!

【Warning】1.In order to prevent fire or electric shock accident, do not expose the controller to the rain or humid environment. There are dangerous high-tension fittings inside the controller, therefore do not open the cover. Entrust the repairing work only to the qualified professional repairing personnel when repairing is required.2.Without the clear approval from the controller manufacturer or its authorized units, anychange or alternation to this controller might bring various inconveniences to the users when in use.

【Attention】1. Please read this operating instruction manual thoroughly, so as to allow you to master the correct use of this controller.2. After reading this operating instruction manual, please keep it safe and for reference in the future. If repairing is required, please contact the local dealer or the technical service center of our company.

【Notice for use】1. In case this controller is not used for a long time, please remove the power plug from the socket.2. Before switching on the power, please make sure that all wirings and power cord have been connected accurately.3. Please put this controller in a ventilated dry area. Prevent it from getting close to the heat source,put it away from direct sunlight, mechanical vibration, dampness and dusty environment, and prevent it from getting close to other thermal-radiating objects.

Dear Guest,Thank you very much for purchasing our sanitary ware. To enable you to use this product safely and effectively, please read this installation and operation manual carefully before use.

1.Please ensure that the product installed reliable electric leakage protection device, the power plug contains earth line, and make sure it is reliable earth line. Check the protect system of leakage protection each time before use.2.Do not turn on water pump, heat pump or air bubble pump without water.3.Before turn on water pump, check if the water level over jets 10 to 20 mm or not, make sure regular usage of water pump otherwise it will be destroy because of water leakage.4.People with Hypertension symptom, after drink or heart disease are not allowed to use the bathtub. Children have a bath must under adult's guidance.5.During use please noticed that don't blocked the jets and avoiding the air adjustment valve overflowing. Also keep the bathtub clean and don't let it blocked by hair or mess.6.During use, please firstly adjust the water temperature or it will be burned.7.The bathtub is designed with ergonomic, rise and fall changes are quite big so during usage pay more attention of be slipped.8.Please shut down the system when not to use.

Page 5: MASSAGE BATHTUB

【Helpful suggestion】1. In order to prolong the service life of this controller, the time interval for continuously turning on and off the machine must be over 30 seconds.2. Please switch off the power after use.3. The power supply used must be consistent with the voltage specified value indicated on this controller; otherwise it will not work, or even burn out the controller.4. When installing this controller, carefully check if the load parameters are consistent with the parameters required by this controller, otherwise it will not work, or even burn out the controller.5. If it is halted accidentally, please close and restart.

II、Brief Introduction

1. Controller System Including:

1) Control panel(1); 2) Control box(1).2. Characteristics of the Controller

1) Rated voltage :AC110V

2) Working voltage range :AC100V ~ AC130V

3) Rated power :60HZ

4) Power consumption :<10W (all loads OFF)

5) Applied ambient temperature :+5℃ ~ +40℃3. Devices controlled by the controlling system

1) Water pump surf : AC110V/1HP

2) Thermostatic heating : AC110V/1500W

3) Blower : AC110V/300W

4) Bottom lamp : DC12V/2W

5) Ozone : DC12V/6W

6) Loudspeaker : 8Ω/15W4.`Remote control

1) Working voltage :3.0VDC2) Power : 2pcs of 7# batteries3) Expected life span of battery: above 1 year

4

Page 6: MASSAGE BATHTUB

1.The remote control is waterproof and dampproof.2.The usage of remote control and the function of control panel is basically the same.3.Lay the remote control with care, and don't throw it.

III Operation of Control PanelWhen any function button works, there is a sound of di“ …”Remote control code checking2.1 the transmission media of this remote control is wireless (non infrared). To avoid one remote control operating several control box, remote control andcontrol box need to do one-to-one code checking.2.2 Remote controller code checking has been done before ex-work shop. There is no need to check the code before using. If the remote controller is found can not be used, please operate the code checking with following instruction.

Code checking procedure:

** Power must be off to the bathtub before the below procedure:Press the power icon on the controller for 8S.

In the state of control panel, press“ ”for 2S,entering controller code checking

state. LCD shows“PAIR”。Within 10S, press any button on the remote controller,

“PAIR” disappears from the LCD with sound Di... Which indicates the code

checking is finished.

1.“ ” power

Press “ ”for 2 seconds to start the controller ,at the same time, the lamp is turned

on ;press the icon again to stop the controller and all the loads is turned off.

2.LAMP

When the system is on, press continuously and till the cursor is on “ ”;

then press“ ”,lamp is turned on;press “ ”another time,lamp is turned off.

Manual

power switch

left switch right switch

confirmation switch

5

Page 7: MASSAGE BATHTUB

3.Lock

If no operation with the control panel for 3 minutes,all the keys will be locked

except “LOCK”,LCD displays “LOCK”.

When the keys were locked,press any key for 3 seconds,the keys will be unlocked

after a“di…”,icon“LOCK”disappear.

4.Ozone (FM radio on,ozone will be turned off automatically)

4.1 When the system is on, press continuously “ 、 ”,when the cursor is on

“ ”press“ ”ozone will be started. And LCD symbol will be displayed

dynamically.Press “ ”again,ozone will be turned off.

4.2 ozone will be turned off automatically after being started 10 minutes.5 BlowerWhen the system is on, press continuously “ ” “ ”till the cursor moved

to “ ”,and then press “ ”to start the blower,the cursor blinks;press again, blower is stopped.6 Water pump surf6.1 The water checking device of this controller protects the water pump from burning out.6.2 When the system is on, press“ ” “ ”till the cursor moved to “ ”,while the water level achieves the setting value ,and then press “ ”to start the

pump,the cursor blinks;press again, Water pump surf is stopped.6.3 When the water level lowers than the setting value, pump stops working.6.4 When the water surf pump function is on, and the system checks the water level lower than the setting value, water surf pump function stops automatically, at the same time the pump icon blinks.When any time the system checks the water level achieves the setting value, the icon stops blink and the pump starts to work.7 FM Radio7.1 The FM frequency scope is 87.5MHz—108.0MHz.7.2 When the system is on, press “ ” “ ”till the cursor moved to “ ”, andthen press “ ” to turn on the FM Radio Function, at the same time, the LCD displays the current frequency and “FM”; press the icon “ ”again ,FM function stops while the current frequency and “FM” disappears.7.3 When the FM function is on, press “ ” till the LCD blinks “FM” and “MHZ”, the system enter into the state of adjusting the frequency.7.3.1 press “ ” to increase the length of one step (the length of one step =100KHz): Press this button over 2 seconds, the system searches the radio stations of larger frequencies automatically; the digital phase locked loop will lockthe FM station automatically and the LCD shows the present frequency, when it reaches to the limit of 108.0MHz, press this button againand the frequency jumps to 87.5MHz.7.3.2 Press “ ” to decrease the length of one step (the length of one step =100KHz).Press this button over 2 seconds, the system searches the radio stationsof smaller frequencies automatically; the digital phase locked loop will lock the FM station automatically and the liquid crystal shows the frequency of this station; When it reaches to the limit of 87.5MHz, press this button again and the frequency jumps to 108.0MHz.

Manual

6

Page 8: MASSAGE BATHTUB

7.4 When the FM radio is on, press“ ”till the LCD blinks “VOL”, and then press “ ”to increase the volume and press “ ”to decrease the volume. The volume adjusting range is 0-20, and 21 in total.7.5 Station storage/select

7.5.1 Station storage:when FM function is on and select the station frequency to be

stored,press “ ” to select the location for storage “CH”and number below it shall blink, and press the icon “ ” “ ”to choose the location(1-18,all18 ); press the icon“ ”, the station frequency shall be stored in the selected storage location.And LCD will resume to current frequency.

7.5.2 station storage:when the station to be stored is chosen, press“ ”for 2S

on the remote controller. LCD blinks with“CH”and the number below,the system

entering station storage state. By pressing “ ” on the controller to adjust the storage position(1-18,totally 18). When the position is chosen, pressing “ ” for 2Sthen the storage is done and LCD resume to display station frequency.

7.5.3 Station select:in FM state,press“ ”. When LCD displays“CH”,select

the according stored station (1-18,totally 18).

7.5.4 Station select:When FM function is on,press “ ” the corresponding

stored station can be selected by press“ ”and “ ”to choose from (1-18,all 18stations)7.5.5 When pressing “ ”and entering a certain function state, within 5 S without

pressing “ ”、“ ”, system will automatically exit that function operationstate.Or by pressing“ ”function choosing key to exit that function.8 Thermostatic heating8.1 This functions works only when the water pump surf function is on.8.2 Press “ ” “ ” till the cursor moved to “ ”,and then press “ ”to start thethermostatic heating function.8.2.1 Thermostatic heating function starts or stops according to the water

temperature and set temperature(the temperature that the system defaults is 37℃)

Controlling rule is as follows:

If the temperature≥setting temperature+1℃,stop heating and LCD heating symbol

blinks;

If the temperature≤setting temperature -1℃,start heating and LCD heating symbol displayed in dynamical way.8.3 Press “ ” again to stop the function.8.4 Temperature adjustment

8.4.1 When the thermostatic heating function is on, press “ ”till “℃”on LCD blinks,then press “ ”or“ ” to adjust the temperature. During the adjusting, LCD ddisplays the setting temperature, then the temperature shall be increased /

decreased 1 ℃ after press“ ” “ ”once;When pressing“ ”or“ ”more that

2S,the temperature will increase or decrease by“1℃ /0.5s”;stop adjusting for

5 seconds,LCD shall display the current water temperature and system exit

temperature adjustment.

Manual

7

Page 9: MASSAGE BATHTUB

8.4.2 when the system is on and the heating function is on, press“ ”on the remotecontroller, at this time the LCD displays temperature. Temperature unit blinks. Then press“ ”or “ ”,temperature will go up or down 1℃;if press “ ”or “ ”

more than 2S,temperature will increase or decrease by“1℃ /0.5S”;If within 5S

“ ”or “ ” is not pressed,then temperature last set will be the setting

temperature. And system will exit temperature setting. LCD displays current water temperature in static state.

8.5 Temperature setting range:35℃--45℃

8.6 If the temperature sensor occurs error, LCD displays “E1” and the controller sounds “di…di…”,in this case the heater cannot be start.9. Blue tooth music play9.1 When the system is on and FM is off, pressing“ ”for 2Sor press“ ”for 2S on the remote controller ,to disconnect the equipment connected with the blue tooth currently. And entering blue tooth pairing state. LCD displays“PAIR”.

9.2 when the system is on, pressing constantly“ 、 ”,and moving the cursor to

“ ”,pressing continuously“ ”,till the LCD displays“BT--C”,then blue

tooth music will be started;press again“ ”,till “BT--C”disappear,blue tooth

music play will be off.

9.3 blue tooth name “PROW-BT”. If pairing is not done,LCD displays“BT--C”;

if pairing is done,LCD displays“BT--C”.

9.4 When the blue tooth music is started, press “ ”,when LCD displays“P--N”,

by pressing“ ”to choose nest song,by pressing “ ”to choose the last song;

by press “ ”and “ ”next song and last song can also be chosen.

9.5 When the blue tooth music is started,pressing“ ”for 2S,to play or pause.

9.6 When the blue tooth music is started,pressing“ ”,when the LCD displays

“VOL”,it enters volume adjusting state. By pressing“ ”to increase volume,and “ ”todecrease volume. Volume adjusting range is from 0-20,total 21.

IV 、Remote control operation instruction1. When any function button works, there is a sound of “di…”2. For function button operation on the remote controller , except the ones with special instruction, they are all the same with the buttons on the control panel.

V、Precautions for Installation and UseUsers must carefully read the following precautions to ensure the normal use of the

product,extension of its service life and the personal safety:1. Users must install loads in strict compliance with the circuit diagrams and parameters supplied by our company.2. The ground wire must be connected to the power supply line with good grounding.3. The end user should use power supply cables in 3 x 3mm2 or wider cable diameter. .According to the National standards (GB). The socket should be of 30A or above

according to the National standards (GB).4. The end user should install air-break or leakage switch of 30A or above according to the National standards (GB).5. Strictly check the power supply wiring of the control box. Power on to use only after no errorsconfirmed.

Manual

8

Page 10: MASSAGE BATHTUB

Attention1. Turn on the power and make sure it won't surpass the electric current.2. Make sure to fix leakage protection device, and the socket must be connected

with earth line.3. Please don't block the water recycle net by any part of your body, if that occurs,

turn off the pump or power at once.4. A switch for the supply of the hot/cool water must be installed, when stop to use

this product. The water supply switch and the power source switch should be turned off.

5. Check the water level if it is 10-20 mm above the spray nozzle before you start the pump or the pump could be damaged.

6. Dispose of this product according to the local law when it is out of use.7. Please contact the local dealer for help if you have any problem.

Circuit diagram

9

6. The electric appliances recommended by illegal manufacturers must not be connected to the controller.Unapproved dismantling and modification of the enclosed internal wiring are strictly prohibited. It is not allowed to connect or plug the wires and plug-in units on the power supply box during the power-on.7. The connecting wires of the power supply box should be connected and plugged correspondingly according to the tags and specifications of theconnectors. The output wires can not be short circuited each other.8. After using, please cut off the power to avoid aging of the device.9. The installation of the controller must be performed in strict compliance with the installation instructions by qualified persons.10. No recoverable elements exist in the controller. Don’t try to improve it by yourself for the high voltage in the controller can cause dangers. The maintenance and adjustment must be performed by professionals.For any consequences caused by wrong operation, the user should bear the responsibility.

Page 11: MASSAGE BATHTUB

Water leaks from the pipes.

1.seal ring is broken2.screws doesn't lock tightly3.pipes doesn't seal properly.4.water pipe is broken

1.chang seal ring2. lock the screws tightly3. re-seal the silicone.4. change water pipe

Control panel doesn't work

1.Electricity line didn't connect to power source, electricity leaking protection device cut off power.2.power button is not working.

1.Re-connect the power source and check the electricity leaking switch button.2.change a new control panel Lighting is off

No lighting1.The bulb is broken2. power line is disconnected.3.control panel is broken

1.change a new bulb.2.re-connect the circuit.3 .maintain or change control panel

Radio is off

1.speaker is broken2. power line is disconnected.3.control panel is broken

1.change a new speaker2.reconnect the circuit.3. maintain or change control panel

Problems Reasons Maintenances

1. turn on the system2. check through and remove the garbage which is inside the pump. Switch pipe can be removed.3. install a new water pump

Water Jets are not working.

1.check the system whether is on.2.the impeller of water pump doesn't rotate3.water pump is broken which caused by working without water coming in.

The intensity of hydro-massage cannot be adjusted

1.water pump's suction has not enough power.2.air adjustment valve is abnormal3.jets or nozzles are blocked

1. check the water pump whether is working normally.2.change the air adjustment valve3. remove things which are blocking the jets.

No power or electricity leaking protection device is activated

1.Electricity leaking protection device cut off power source when electricity line is not well connected.2.Power or electricity circuit have phenomenon of electricity leaking.

1.check and reconnect the wiring 3system.2.check the power source, electricity circuit and ground line.

Troubleshooting

1.please use it at the normal situation of voltage2. check and change the switch3.maintain and change the control panel4.get rid of mess of the jets.

Jets shower cannot be work

1. voltage is abnormal 2 .Switch cannot be work 3.control panel cannot be work4. water in electromagnetism valve is be blocked

10

Page 12: MASSAGE BATHTUB

Cleaning and Maintenance

1. The daily maintenance should be cleaned with ordinary detergent and soft cloth. Please do not use the detergent which contains acetone or ammonia liquid. If there marks or something like glue on the surface of bathtub, just polish it with soft cloth dipping with gas.

2. If there are scratches on bathtub surface, please polish it with 1500# frosted paper dipping with liquid and burnish it with toothpaste. It will be shining again after that.

3. If there are furring on the surface of bathtub, it can be take away by mild acid detergent, for example wipe the bathtub with lemon juice or vinegar which be heated.

4. Do not wipe the chrome plated spare parts all the time, and do not get in touch with chemical detergent etc. Otherwise the surface of chrome plated will be destroyed. The product should be clean by soft cloth other than coarse cloth.

5. To check the water pipe regularly in order to avoid troubles from crack of water pipes or blocked inside.

6. If there are something such as hair stuck inside the jets, then just to twist out the jets and remove it.

7. To clean hydro-massage equipment: To full fill hot water which is 40'C, and pour 2g/L detergent, start hydro-massage function more than 5 minutes, then turn off the massage function and drain out the water. Next, to full fill cold water and start hydro-massage function for 3 minutes, then turn off the massage function and drain out the water, at last, to dry the bathtub with towel.

8. Filter should be clean once a week.

9. Keep out from combustibles and goods which over 80°C to avoid fire disaster and damage the product.

10.The bathtub should be transported carefully. Do not lay heavy things on it and do not bump and shaking the tub. If the bathtub has not been used for a long time, drain out the water of the bathtub and keep it in a dry and ventilate environment. Avoid corrosive gas.

Do not dispose this product as unsorted municipal

waste. Collection of such waste separately for special