project no dwg no rev scale size A3 date design drawn check approve title project project address General Note: Builder to check and verify all dimensions, levels, etc. as noted on this/these drawings and be fully aware of any additional notes on approved copy of same drawing before commencing any setting out of works, ordering of materials, and/or construction work. All works must comply with the Building Code of Australia, Australian Standards and all other relevant authorities. All work must be carried out in the best of tradesman like manner and to the full satisfaction of the owner koda design pty ltd 6/99 musgrave road red hill qld 4059 acn 137 818 645 BDAQ Member No: 1208 BSA License No: 1170922 t (07) 35116446 e [email protected] w www.kodadesign.com.au client Escape Homes p 1300 725 514 m 0431 421 181 w escapehomes.com.au e [email protected] COPYRIGHT: THESE DRAWINGS ARE THE EXCLUSIVE PROPERTY OF KODA DESIGN PTY. LTD. AND MAY NOT BE LOANED OR COPIED IN WHOLE OR PART WITHOUT WRITTEN CONSENT C B B B 03.10.13 3/10/2013 7:03:56 AM 3043 3043 3043 3043 A000 A000 A000 A000 DNP DNP DNP MZ Cover Sheet Cover Sheet Cover Sheet Cover Sheet PROPOSED RESIDENCE PROPOSED RESIDENCE PROPOSED RESIDENCE PROPOSED RESIDENCE LOT 37 ANASTASIA STREET WEST MACKAY QLD FOR APPROVAL MARY PURASH MARY PURASH MARY PURASH MARY PURASH MARY PURASH LOT 37 ANASTASIA STREET, WEST MACKAY QLD DRAWING SCHEDULE NO DWG TITLE REV REV DATE A000 Cover Sheet B 03.10.13 A001 Project Notes & Legends B 03.10.13 A011 Site Plan B 03.10.13 A101 Floor Plan B 03.10.13 A111 Slab Setout Plan B 03.10.13 A121 Elec Power Layout B 03.10.13 A122 Elec Lighting Layout B 03.10.13 A131 Framing & Bracing Plan (refer eng.) B 03.10.13 A201 Elevations B 03.10.13 A301 Typical Section A-A B 03.10.13 A401 3d Overview 1 B 03.10.13 REVISION SCHEDULE REVISION SCHEDULE REVISION SCHEDULE REVISION SCHEDULE A FOR APPROVAL 25.09.13 B GENERAL AMMENDMENTS 03.10.13

Upload: others

Post on 11-Oct-2020

2 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: MARY PURASH LOT 37 ANASTASIA STREET, WEST MACKAY QLD · 2014. 11. 12. · bca, australian standards, relevant supplements & all other relevant authorities. 5. all timber framing to

project no dwg no rev

scale sizeA3

date

design drawn check approve

title

project

project address

General Note: Builder to check and verify all dimensions, levels,etc. as noted on this/these drawings and be fully aware of anyadditional notes on approved copy of same drawing beforecommencing any setting out of works, ordering of materials,and/or construction work. All works must comply with theBuilding Code of Australia, Australian Standards and all otherrelevant authorities. All work must be carried out in the best oftradesman like manner and to the full satisfaction of the owner

koda design pty ltd6/99 musgrave road red hill qld 4059

acn 137 818 645BDAQ Member No: 1208 BSA License No: 1170922

t (07) 35116446e [email protected] www.kodadesign.com.au

client

Escape Homesp 1300 725 514m 0431 421 181

w escapehomes.com.aue [email protected]

COPYRIGHT: THESE DRAWINGS ARE THE EXCLUSIVE PROPERTY OF KODA DESIGN PTY. LTD. AND MAY NOT BE LOANED OR COPIED IN WHOLE OR PART WITHOUT WRITTEN CONSENTC

BBBB

03.10.13

3/10/2013 7:03:56 AM

3043304330433043 A000A000A000A000

DNP DNP DNP MZ

Cover SheetCover SheetCover SheetCover Sheet

PROPOSED RESIDENCEPROPOSED RESIDENCEPROPOSED RESIDENCEPROPOSED RESIDENCE

LOT 37 ANASTASIA STREET

WEST MACKAY QLD

FOR APPROVAL

MARY PURASHMARY PURASHMARY PURASHMARY PURASH

MARY PURASHLOT 37 ANASTASIA STREET, WEST MACKAY QLD

DRAWING SCHEDULE

NO DWG TITLE REV REV DATE

A000 Cover Sheet B 03.10.13

A001 Project Notes & Legends B 03.10.13

A011 Site Plan B 03.10.13

A101 Floor Plan B 03.10.13

A111 Slab Setout Plan B 03.10.13

A121 Elec Power Layout B 03.10.13

A122 Elec Lighting Layout B 03.10.13

A131 Framing & Bracing Plan (refer eng.) B 03.10.13

A201 Elevations B 03.10.13

A301 Typical Section A-A B 03.10.13

A401 3d Overview 1 B 03.10.13

REVISION SCHEDULEREVISION SCHEDULEREVISION SCHEDULEREVISION SCHEDULE

A FOR APPROVAL 25.09.13

B GENERAL AMMENDMENTS 03.10.13

tracyh
Received (Manual Date)
Page 2: MARY PURASH LOT 37 ANASTASIA STREET, WEST MACKAY QLD · 2014. 11. 12. · bca, australian standards, relevant supplements & all other relevant authorities. 5. all timber framing to

project no dwg no rev

scale sizeA3

date

design drawn check approve

title

project

project address

General Note: Builder to check and verify all dimensions, levels,etc. as noted on this/these drawings and be fully aware of anyadditional notes on approved copy of same drawing beforecommencing any setting out of works, ordering of materials,and/or construction work. All works must comply with theBuilding Code of Australia, Australian Standards and all otherrelevant authorities. All work must be carried out in the best oftradesman like manner and to the full satisfaction of the owner

koda design pty ltd6/99 musgrave road red hill qld 4059

acn 137 818 645BDAQ Member No: 1208 BSA License No: 1170922

t (07) 35116446e [email protected] www.kodadesign.com.au

client

Escape Homesp 1300 725 514m 0431 421 181

w escapehomes.com.aue [email protected]

COPYRIGHT: THESE DRAWINGS ARE THE EXCLUSIVE PROPERTY OF KODA DESIGN PTY. LTD. AND MAY NOT BE LOANED OR COPIED IN WHOLE OR PART WITHOUT WRITTEN CONSENTC

BBBB

03.10.13

3/10/2013 7:03:57 AM

3043304330433043 A001A001A001A001

DNP DNP DNP MZ

Project Notes &Project Notes &Project Notes &Project Notes &

LegendsLegendsLegendsLegends

PROPOSED RESIDENCEPROPOSED RESIDENCEPROPOSED RESIDENCEPROPOSED RESIDENCE

LOT 37 ANASTASIA STREET

WEST MACKAY QLD

FOR APPROVAL

MARY PURASHMARY PURASHMARY PURASHMARY PURASH

1. PARTICLEBOARD FLOORING19mm THICK YELLOW TONGUE PARTICLEBOARDGLUED & NAILED TO TOP END OF JOISTS. NAILSSHALL BE 10mm FROM ALL EDGES & AT 150 CTRS ATENDS & AT 300 MAX. CTRS. AT INTERMEDIATE JOISTS2. TONGUE & GROOVE FLOORINGBOARDS SHALL BE FITTED INTO GROOVES &CRAMPED. NAILS SHALL BE 12mm FROM BOARDENDS & BUTT JOINTS, & PUNCHED 3mm MIN. BELOWTOP SURFACE.3. MANUFACTURERINSTALL FLOORING AS PER MAUFACTURER'S SPECS4. STRUCTURALREFER STRUCTURAL ENG'S DWGS FOR ADDITIONALFLOORING DETAILS PRIOR TO INSTALLATION5. FLOOR WASTESFLOORS TO ALL WET AREAS TO HAVE A FALL TO AFLOOR WASTE6. WET AREAS - FIRST FLOORSALL WET AREAS TO A FIRST FLOOR TIMBER FLOORSYSTEM TO HAVE AN APPROVED "WET AREA"FLOORING FIXED IN ACCORDANCE WITH THEMANUFACTURER'S SPECS.

NOTES - FLOORING1. ALL DIMENSIONS AND RL's TO BE CHECKED ONSITE BEFORE COMMENCING ANY WORK.2. ALL DIMENSIONS IN MILLIMETRES.3. DO NOT SCALE FROM PLAN. DIMENSIONS TAKEPREFERENCE TO SCALE, & ARE TO STRUCTURE, NOTFINISH, UNLESS NOTED OTHERWISE.4. ALL BUILDING WORK TO COMPLY WITH CURRENTBCA, AUSTRALIAN STANDARDS, RELEVANTSUPPLEMENTS & ALL OTHER RELEVANTAUTHORITIES.5. ALL TIMBER FRAMING TO COMPLY WITH AS1684 &RELEVANT SUPPLEMENTS.6. ALL NEW PLUMBING TO BE CARRIED OUT BY ALICENSED PLUMBER & IS TO BE IN ACCORDANCEWITH ALL RELEVANT AUTHORITIES.7. ALL AREAS NOT ON THE PROPERTY MADE GOODBY THE BUILDER WHERE DISTURBED BY NEW WORK.8. INSTALL SMOKE DETECTORS WHERE REQUIRED INACCORDANCE WITH AS3876.9. ALL FOOTINGS, SLABS, BEAMS, COLUMNS, LINTELS,BRACING & STRUCTURAL MEMBERS TO BE DESIGNED& CERTIFIED BY A QUALIFIED ENGINEER, UNLESSNOTED OTHERWISE10. ALL DEMOLITION WORK TO BE CERTIFIED BYBUILDER AND/OR A QUALIFIED ENGINEER, UNLESSNOTED OTHERWISE11. CONNECT NEW DPs & OVERFLOWS. CONFIRMLOCATION OF STORMWATER TIE, EASEMENTS, & ALLOTHER SERVICES ON SITE BEFORE COMMENCINGWORK.12. PROTECT ALL WALL PENETRATIONS, CAVITIES, &TIMBER MEMBERS WITH AN AUSTRALIAN STANDARDSAPPROVED TERMITE PROTECTION BARRIER SYSTEM,SUCH THAT AN INTERNAL INFESTATION IS NOTPOSSIBLE.13. THE BUILDER IS TO CONFIRM ALL WALLLOCATIONS ON SITE PRIOR TO CONSTRUCTION, TOENSURE NEW BUILDING ENVELOPE FALLS WITHINCOUNCIL SETBACKS AND EASEMENTS.14. ALL TIMBER FRAMED WALLS TO WET AREAS TOBE LINED WITH FIBRE CEMENT SHEETING15. MASONRY CONSTRUCTION TO AS 3700.16. ALL HANDRAILS TO BE 1000mm MIN. ABOVEFINISHED FLOOR (CARPET, TILES ETC), & WITH125mm MAX. SPACING BETWEEN BALUSTRADING17. MATERIALS USED THROUGHOUT TO BE FIXED INACCORDANCE WITH MANUFACTURER'SSPECIFICATIONS UNLESS NOTED OTHERWISE

NOTES - GENERAL

NOTES - MATERIALS1. EXTERNALREFER ELEVATIONS AND FINISHES SCHEDULE (IFPROVIDED) FOR ALL EXTERNAL FINISHES2. INTERNALREFER FINISHES SCHEDULE (IF PROVIDED).TYPICALLY INTERNAL FINISHES ARE AS FOLLOWSUNLESS NOTED OTHERWISE: Internal Walls: 13mm Plasterboard Wet Area Walls: 6mm Villaboard Internal Ceilings: 10mm Plasterboard External Soffits: 6mm Villaboard3. WHERE A FIXTURES SCHEDULE IS NOT PROVIDED,FIXTURES ARE TO BE SELECTED BY THE BUILDERAND / OR OWNER4. WHERE COLOURS ARE NOT PROVIDED, COLOURSARE TO BE SELECTED BY THE BUILDER AND / OROWNER AND ARE TO COMPLY WITH COUNCIL POLICYAND OTHER RELEVANT AUTHORITIES5. REFER PLANS FOR FLOOR FINISHES. ALLDIFFERING ADJACENT FLOOR FINISHES TO BEFINISHED FLUSH UNLESS NOTED OTHERWISE

NOTES - ROOFING1. TRUSSESTRUSS DESIGN & PLACEMENT OF TRUSSES AS PERMANUFACTURERS DETAILS. BRACING OF TRUSSESAS PER MANUFACTURERS DETAILS2. GUTTERS & DOWNPIPESGUTTERS & DOWNPIPES INSTALLED INACCORDANCE WITH PART 3.5.2 OF THE B.C.A.GUTTERS INSTALLED WITH A FALL OF NOT LESSTHAN -(A) 1:500 FOR EAVES GUTTERS(B) 1:100 FOR BOX GUTTERSDOWNPIPES MUST NOT SERVE MORE THAN 12m OFGUTTER LENGTH FOR EACH DOWNPIPEGENERALLY PROVIDE ONE DOWNPIPE FOR EVERY40sqm OF ROOF AREA (BASED ON A GUTTERMINIMUM CROSS SECTIONAL AREA OF 6300sqmm)3. ROOF SHEETING / TILESINSTALL ROOF MATERIAL AS PER MANUFACTURER'SSPEC & DETAILS. ASSOCIATED ROOF BATTENSINSTALLED ACCORDINGLY4. STRUCTUREALL STRUCTURAL ROOFING MEMBERS TO BEDESIGNED &/OR CERTIFIED BY A QUALIFIED ENG.

NOTES - SERVICES1. ALL NEW PLUMBING TO BE CARRIED OUT BY ALICENSED PLUMBER AND IS TO BE IN ACCORDANCEWITH ALL RELEVANT AUTHORITIES2. CONNECT NEW DPs AND OVERFLOWS. CONFIRMLOCATION OF STORMWATER TIE, EASEMENTS, ANDALL OTHER SERVICES ON SITE BEFORECOMMENCING WORK.3. PRIOR TO ANY EXCAVATION OR CONSTRUCTIONON THE SITE, ALL RELEVANT AUTHORITIES ARE TOBE CONTACTED FOR POSSIBLE LOCATION OFUNDERGROUND SERVICES4. ALL PLUMBING & DRAINAGE TO COMPLY WITHTHE SEWERAGE & WATER SUPPLY ACT 1949, THENATIONAL PLUMBING DRAINAGE CODE AS 3500 ANDANY LOCAL AUTHORITY REQUIREMENTS

NOTES - SITE

1. SITE TO BE EXCAVATED AND/OR FILLED TOLEVELS AS SHOWN2. FOOTINGS CONSTRUCTED AS PER BUILDERSSPEC. OR ENG'S DETAILS3. GROUND SURFACE TO BE SLOPED MINIMUM 1:20AWAY FROM BUILDING FOR MINIMUM 900mm OR TO APOINT WHERE PONDING WILL NOT OCCUR NEAR THEBUILDING4. STORMWATER TO BE DISCHARGED TO COUNCILAPPROVED DISCHARGE POINT5. CUT & FILL INDICATED ON PLAN MAY VARY ATCONSTRUCTION STAGE. BUILDER IS TO VERIFY &ADJUST AS REQUIRED. ANY VARIATION IS TOCOMPLY WITH COUNCIL POLICY & OTHER RELEVANTAUTHORITIES6. SITE WORKS INDICATED ON RELEVANT DRAWINGSARE FOR CONSTRUCTION PURPOSES ONLY, IT ISTHE CLIENTS RESPONSIBILITY TO CARRY OUR ALLLANDSCAPING, UNLESS NOTED OTHERWISE.7. RETAINING WALLS CONSTRUCTED AS PERBUILDERS SPEC. OR ENG'S DETAILS, & ARE TOCOMPLY WITH COUNCIL POLICY & OTHER RELEVANTAUTHORITIES8. CONTOURS & LEVELS AS SHOWN ON DRAWINGSARE DERIVED FROM SUPPLIED SURVEY DRAWING.NO RESPONSIBILITY IS TAKEN FOR ACCURACY OFSURVEY INFORMATION9. BOUNDARY CLEARANCES SHOWN ARE TO BECHECKED & VERIFIED BY BUILDER AT SETOUT &PRIOR TO COMMENCEMENT OF CONSTRUCTION. ANYVARIATION TO SETOUT DIMENSIONS MUST COMPLYWITH COUNCIL POLICY & OTHER RELEVANTAUTHORITIES10. ALL FENCING BY OWNER UNLESS NOTEDOTHERWISE & ARE NOT TO EXCEED 1.8 METRESABOVE NATURAL GROUND LEVEL11. UNLESS NOTED OTHERWISE, REMOVAL OFEXISTING TREES & CONSTRUCTION OF RETAININGWALLS WHERE REQUIRED SHALL BE PROVIDED BYTHE OWNER12. DRIVEWAY SLOPE NOT TO EXCEED 1 VERTICALTO 5 HORIZONTAL. DRIVEWAY & FOOTPATH CROSSOVER BY OWNER.13. PRIOR TO ANY EXCAVATION OR CONSTRUCTIONON THE SITE, ALL RELEVANT AUTHORITIES ARE TOBE CONTACTED FOR POSSIBLE LOCATION OFUNDERGROUND SERVICES

NOTES - STRUCTURE1. ALL CONCRETE FOOTINGS, SLABS, BEAMS &COLUMNS TO BE DESIGNED & CERTIFIED BY AQUALIFIED ENGINEER2. SLAB SETOUT PLANS (IF PROVIDED) ARE FORSETOUT ONLY. DETAILS TO BE PROVIDED BYQUALIFIED ENGINEER.3. ALL STEEL STRUCTURAL MEMBERS TO BEDESIGNED & CERTIFIED BY A QUALIFIED ENGINEER.4. ALL DEMOLITION WORK TO BE CERTIFIED BYBUILDER AND/OR A QUALIFIED ENGINEER.5. ENGINEER TO PROVIDE SOIL REPORT PRIOR TOTHE COMMENCEMENT OF ANY WORKS ON SITE. SITETO BE PREPARED IN ACCORDANCE WITH SOILREPORT6. TIMBER MEMBERS DEDUCED FROM AS1684FRAMING MANUALS, MANUFACTURER'S DATAMANUALS & SOFTWARE. REFER ENGINEERSDRAWINGS WHERE NOT PROVIDED7. ALL LAMINATED BEAMS TO HAVE FULL WIDTHBEARING AT EACH END.8. ALL STRUCUTRAL MEMBERS PROVIDED BY THEBUILDING DESIGNER TO BE CERTIFIED BY AQUALIFIED ENGINEER.

NOTES - SUSTAINABLE DESIGN

1. 3 STAR RATED OR AAA RATED SHOWER ROSESA SHOWER ROSE MUST ACHIEVE A MINIMUM 3 STARWATER EFFICIENCY LABELLING & STANDARDS RATING(WELS)2. WATER PRESSURE LIMITINGTHE MAXIMUM PRESSURE LEVEL OF WATER FROMANY OUTLET WITHIN THE PROPERTY BOUNDARIES OFA CLASS 1 BUILDING MUST NOT EXCEED 500kPa3. DUAL FLUSH TOILETSA TOILET MUST HAVE DUAL FLUSH CAPABILITY &MUST ACHIEVE A MINIMUM 4 STAR WATEREFFICIENCY LABELLING & STANDARDS RATING (WELS)4. ENERGY EFFICIENT LIGHTINGENERGY EFFICIENT LIGHTING INCLUDES FLUORO &COMPACT FLUORO LIGHTS. IT DOES NOT INCLUDEINCANDESCENT OR HALOGEN LIGHTS.ENERGY EFFICIENT LIGHTS ARE TO BE USED FOR ATLEAST 80% OF THE TOTAL FLOOR AREA OF THEBUILDING, WHICH INCLUDES GARAGES. ELECTRICIANMUST ADVISE ON COMPLIANCE.5. HOT WATER SUPPLYA HOT WATER SYSTEM IN A CLASS 1 BUILDING MUSTCOMPLY WITH THE QUEENSLAND PLUMBING &WASTEWATER CODE.6. RAINWATER TANKS (If Applicable)A RAINWATER TANK -(A) HAS A MINIMUM STORAGE CAPACITY OF 5000LFOR A DETACHED CLASS 1 BUILDING(B) IS INSTALLED TO RECIEVE RAINWATER FROM AMINIMUM ROOF CATCHMENT AREA THAT IS AT LEASTONE HALF OF THE TOTAL ROOF AREA OR 100sqm,WHICHEVER IS THE LESSER(C) IS CONNECTED TO TOILET CISTERNS ANDWASHING MACHINE COLD WATER TAPS, EXTERNALUSE (HOSE COCKS) & OTHER FIXTURES AS SPECIFIEDBY THE LOCAL GOVERNMENT IN A LOCAL PLANNINGINSTRUMENT.7. GREYWATERWHERE A GREYWATER TREATMENT PLANT ISINSTALLED IT WILL -RECIEVE GREYWATER FROM ALL BATHROOMSANITARY OUTLETS IN THE BUILDING, HAVE AMINIMUM PROCESSING CAPACITY TO TREAT TOTALGREYWATER INPUT VESSEL VOLUME IN 24 HOURS,AND HAS A STORAGE CAPACITY NOT EXCEEDING2000L

PART MP 4.0 - BUILDING SUSTAINABILITYQUEENSLAND DEVELOPMENT CODE

NOTES - TERMITE PROTECTION1. TIMBER PROTECTION FROM TERMITES INACCORDANCE WITH AS36602. BUILDER TO CONFIRM WITH OWNER THE CHOSENMETHOD OF TIMBER PROTECTION3. OWNER REMAINS RESPONSIBLE FOR ONGOINGINSPECTIONS OF STRUCTURAL TIMBER, & THATBARRIERS ARE NOT COMPROMISED4. INSTALL ANT CAPPINGS TO ALL BRICK PIERS,TIMBER OR CONCRETE STUMPS. KEEP TIMBERCLEAR OF GROUND WHEN ON STEEL ANCHORS5. ALL TIMBER IN DIRECT CONTACT WITHCONCRETE TO BE SEPERATED BY G.I. FLASHING OROTHER APPROVED METHOD / MATERIAL6. 75mm MIN. OF EXPOSED SLAB EDGES TO REMAINABOVE FINISHED PERIMETER LEVEL AND NOT TO BECOVERED BY SOIL, OR RENDERED, OR TILED, BUTMAY BE PAINTED.

REVISION SCHEDULEREVISION SCHEDULEREVISION SCHEDULEREVISION SCHEDULE

A FOR APPROVAL 25.09.13

B GENERAL AMMENDMENTS 03.10.13

LEGEND - GENERALAW AWNING WINDOWBH BULKHEADBN BENCHCH CEILING HEIGHTCL COLUMN / POSTCPT CARPETCSD CAVITY SLIDING DOORCT COOKTOPDH DOUBLE HUNG WINDOWDP DOWNPIPEDRY CLOTHES DRYERDW DISHWASHERFG FIXED GLAZED WINDOWFGD FROSTED GLASS DOORFRD FRENCH DOUBLE DOORSFRZ FREEZERFW FLOOR WASTEGD GLASS DOORHC EXTERNAL HOSE COCKHWS HOT WATER SYSTEMLV LOUVRE WINDOWMB METER BOXMH MANHOLEOBS OBSCURE GLAZINGPLD PANEL LIFT DOORRD ROLLER DOORSD SMOKE DETECTORSGD SLIDING GLASS DOORSHR SHOWERSK KITCHEN SINKSL SLIDING WINDOWSSWB STAINLESS STEEL WIRE BALUSTRADEREF FRIDGERH RANGEHOODRWT RAINWATER TANKTMB FB TIMBER FLOOR BOARDSTUB LAUNDRY TUBUBO UNDER BENCH OVENVB VANITY BASINWC TOILET SUITEWO WALL OVENWM WASHING MACHINE

SUFFIXES (following any of the above - lower case)o overu under

STANDARD LIGHT, BATTEN HOLDER

1. light switch mount height @ 1250AFFL, uno2. powerpoint mount height @ 300AFFL, uno3. if not stated, provide electrical connection to oven,cooktop, rangehood and dishwasher4. refer general legend for all acronyms not covered inthis legend

F

MS

W

P

D

F

MB

SD

L

LEGEND - GENERAL

LIGHTING

DOWNLIGHT, FLUORO

FLOOD LIGHT

MOTION LIGHT SENSOR

WALL MOUNTED LIGHT

FLUORO BATTEN, 1x1200 LONG

PENDANT LIGHT

FLUORO ROUND LIGHT

LIGHT SWITCH

LIGHT SWITCH, 2 WAY

DIMMER SWITCH

FAN SWITCH, ON / OFF, SPEED

3 in 1 FAN / LIGHT / HEATER

POWER

A/C INT

A/C EXT

SINGLE GPO

DOUBLE GPO

TV OUTLET

PHONE OUTLET

DATA OUTLET

DOUBLE DATA OUTLET

METER BOX

INTERCOM WITH DOOR RELEASE

CEILING FAN

CEILING FAN WITH LIGHT

EXHAUST FAN

A/C UNIT, INTERNAL WALL

A/C UNIT, EXTERNAL

OTHER

SMOKE DETECTOR

SUFFIXES

FACE OF BENCHANY NUMERAL FOLLOWING ANY OFTHE ABOVE ACRONYMS INDICATESHEIGHT OF FIXTURE / FITTING

OVERUNDERWATERPROOF

FB1500*

OUWP

NOTES

Page 3: MARY PURASH LOT 37 ANASTASIA STREET, WEST MACKAY QLD · 2014. 11. 12. · bca, australian standards, relevant supplements & all other relevant authorities. 5. all timber framing to

dp

dp

dp

dp

dp

dp

dp

37.50m

64°24'00"

13.50m 334°24'00"

13.50m 154°24'00"

Anastasia Street

METER BOX (MB)

SELECTED HWS

1800 HIGH 'GOODNEIGHBOUR' TIMBER PALINGFENCE TO REAR AND SIDEBOUNDARIES (UP TO HOUSEFRONT AS SHOWN)

CONCRETE DRIVEWAYAND PATH

PROPOSED

DWELLING(ROOF AREA: 245sqm)

CLOTHESLINE

37.50m

64°24'00"

GATE

900 12100 (EAVES) 500

900 10150 (EAVES) 2450

5000

20980 (EAVES)

1152

0

6070

20940 (EAVES)

1049

0

EMT E (41sqm) 3000

project no dwg no rev

scale sizeA3

date

design drawn check approve

title

project

project address

General Note: Builder to check and verify all dimensions, levels,etc. as noted on this/these drawings and be fully aware of anyadditional notes on approved copy of same drawing beforecommencing any setting out of works, ordering of materials,and/or construction work. All works must comply with theBuilding Code of Australia, Australian Standards and all otherrelevant authorities. All work must be carried out in the best oftradesman like manner and to the full satisfaction of the owner

koda design pty ltd6/99 musgrave road red hill qld 4059

acn 137 818 645BDAQ Member No: 1208 BSA License No: 1170922

t (07) 35116446e [email protected] www.kodadesign.com.au

client

Escape Homesp 1300 725 514m 0431 421 181

w escapehomes.com.aue [email protected]

COPYRIGHT: THESE DRAWINGS ARE THE EXCLUSIVE PROPERTY OF KODA DESIGN PTY. LTD. AND MAY NOT BE LOANED OR COPIED IN WHOLE OR PART WITHOUT WRITTEN CONSENTC

BBBB

03.10.13 1 : 200

3/10/2013 7:03:59 AM

3043304330433043 A011A011A011A011

DNP DNP DNP MZ

Site PlanSite PlanSite PlanSite Plan

PROPOSED RESIDENCEPROPOSED RESIDENCEPROPOSED RESIDENCEPROPOSED RESIDENCE

LOT 37 ANASTASIA STREET

WEST MACKAY QLD

FOR APPROVAL

MARY PURASHMARY PURASHMARY PURASHMARY PURASH

SCALE 1 : 200

1 Site Plan

PROPERTY DETAILS

NOTE: CHECK BOUNDARY DIMENSIONS &CONTOURS ON SITE PRIOR TO CONSTRUCTION

LOT NUMBER:RP/SP NUMBER:PARISH:COUNTY:LOCAL AUTHORITY:SITE ZONING:PRECINCT:

PROPERTY INFORMATION

SITE AREA:EXISTING FOOTPRINT:

PROPOSED FOOTPRINT:

SITE AREA INFORMATION

NOTE: FOOTPRINT CALCULATED TO OUTSIDE EXT.WALLS. INCLUDES OUTDOOR COVERED AREAS

37SP253156

506sqm

MACKAY CC

N/A

200.4sqm39.6%

NOTES - SITE1. SITE TO BE EXCAVATED AND/OR FILLED TOLEVELS AS SHOWN2. FOOTINGS CONSTRUCTED AS PER BUILDERSSPEC. OR ENG'S DETAILS3. GROUND SURFACE TO BE SLOPED MINIMUM 1:20AWAY FROM BUILDING FOR MINIMUM 900mm OR TO APOINT WHERE PONDING WILL NOT OCCUR NEAR THEBUILDING4. STORMWATER TO BE DISCHARGED TO COUNCILAPPROVED DISCHARGE POINT5. CUT & FILL INDICATED ON PLAN MAY VARY ATCONSTRUCTION STAGE. BUILDER IS TO VERIFY &ADJUST AS REQUIRED. ANY VARIATION IS TOCOMPLY WITH COUNCIL POLICY & OTHER RELEVANTAUTHORITIES6. SITE WORKS INDICATED ON RELEVANT DRAWINGSARE FOR CONSTRUCTION PURPOSES ONLY, IT ISTHE CLIENTS RESPONSIBILITY TO CARRY OUR ALLLANDSCAPING, UNLESS NOTED OTHERWISE.7. RETAINING WALLS CONSTRUCTED AS PERBUILDERS SPEC. OR ENG'S DETAILS, & ARE TOCOMPLY WITH COUNCIL POLICY & OTHER RELEVANTAUTHORITIES8. CONTOURS & LEVELS AS SHOWN ON DRAWINGSARE DERIVED FROM SUPPLIED SURVEY DRAWING.NO RESPONSIBILITY IS TAKEN FOR ACCURACY OFSURVEY INFORMATION9. BOUNDARY CLEARANCES SHOWN ARE TO BECHECKED & VERIFIED BY BUILDER AT SETOUT &PRIOR TO COMMENCEMENT OF CONSTRUCTION. ANYVARIATION TO SETOUT DIMENSIONS MUST COMPLYWITH COUNCIL POLICY & OTHER RELEVANTAUTHORITIES10. ALL FENCING BY OWNER UNLESS NOTEDOTHERWISE & ARE NOT TO EXCEED 1.8 METRESABOVE NATURAL GROUND LEVEL11. UNLESS NOTED OTHERWISE, REMOVAL OFEXISTING TREES & CONSTRUCTION OF RETAININGWALLS WHERE REQUIRED SHALL BE PROVIDED BYTHE OWNER12. DRIVEWAY SLOPE NOT TO EXCEED 1 VERTICALTO 5 HORIZONTAL. DRIVEWAY & FOOTPATH CROSSOVER BY OWNER.13. PRIOR TO ANY EXCAVATION OR CONSTRUCTIONON THE SITE, ALL RELEVANT AUTHORITIES ARE TOBE CONTACTED FOR POSSIBLE LOCATION OFUNDERGROUND SERVICES

REVISION SCHEDULEREVISION SCHEDULEREVISION SCHEDULEREVISION SCHEDULE

A FOR APPROVAL 25.09.13

B GENERAL AMMENDMENTS 03.10.13

NORTH

Page 4: MARY PURASH LOT 37 ANASTASIA STREET, WEST MACKAY QLD · 2014. 11. 12. · bca, australian standards, relevant supplements & all other relevant authorities. 5. all timber framing to

Garageconc

Bed 2carpet

Ldrytile

Bathtile

Bed 4carpet

Bed 3carpet

Enstile

WIRcarpet

Bed 1tile

Alfrescotile

Porchag. conc

Robe

Linen

Robe

230

3000

701900

702000

703000

7090

070

1410

903400

703200

230

1030

2030

3240

5070

2540

6900

230

6000

703000

704000

703570

230

2500

6460

2840

3840

4100

2500

70 2640 70 1600 70 1000 55070 5800 230

600 230 2950 70530230 1230 230 5800 230

4010 1230 6260

070 2400 70 1840 70 1000 70 4560 70

230 3550 70 1000 70 3800 230 600

230 3550 230 4940

Robe

Diningtile

Media / Livingtile

Kitchentile

230 2950 7053070 1000 70 600 3200 230

1070

230

4930

701000

701100

701830

703700

7053

070

3270

230

2150

350

Robe

Study

Nook

600

1974

060

0

600

230

1800

701130

7093

070

900

702000

701130

701800

702380

903400

701730

1470

23068

035

0

600

1978

060

0

600 11500

600 8950 600

brick col.

brick col.brick col.

brick col.brick col.

WMTUB

WC

FW

FW

FW

BATH

VB

SHR

SHR

WC

VBFW

CT

RH

UBO

REF

SK DW

SD

SD

550

1

A301

D15

D01

D02

D05

D16

D06

D09

D10

D11

D12

D13D14

D17

D07

D08

D18

D20

D19

/1.8 0.9SWW01

/1.8 0.9SWW02

/0.91.8SW

W04

/0.91.8SW

W11

/0.61.5SW

W05

/1.22.1SW

W06

/1.2 1.8SWW07

/1.20.9D

HW08

D03

/0.61.5SW

W03

/0.62.4SW

W10

/0.61.5SW

W09

D04

BOUNDARY WALL TO ACHIEVE 60/60/60 FRL

MB

HWS

HC

HC

dp

dp

dp

dp

dp

dp

project no dwg no rev

scale sizeA3

date

design drawn check approve

title

project

project address

General Note: Builder to check and verify all dimensions, levels,etc. as noted on this/these drawings and be fully aware of anyadditional notes on approved copy of same drawing beforecommencing any setting out of works, ordering of materials,and/or construction work. All works must comply with theBuilding Code of Australia, Australian Standards and all otherrelevant authorities. All work must be carried out in the best oftradesman like manner and to the full satisfaction of the owner

koda design pty ltd6/99 musgrave road red hill qld 4059

acn 137 818 645BDAQ Member No: 1208 BSA License No: 1170922

t (07) 35116446e [email protected] www.kodadesign.com.au

client

Escape Homesp 1300 725 514m 0431 421 181

w escapehomes.com.aue [email protected]

COPYRIGHT: THESE DRAWINGS ARE THE EXCLUSIVE PROPERTY OF KODA DESIGN PTY. LTD. AND MAY NOT BE LOANED OR COPIED IN WHOLE OR PART WITHOUT WRITTEN CONSENTC

BBBB

03.10.13 1 : 100

3/10/2013 7:04:00 AM

3043304330433043 A101A101A101A101

DNP DNP DNP MZ

Floor PlanFloor PlanFloor PlanFloor Plan

PROPOSED RESIDENCEPROPOSED RESIDENCEPROPOSED RESIDENCEPROPOSED RESIDENCE

LOT 37 ANASTASIA STREET

WEST MACKAY QLD

FOR APPROVAL

MARY PURASHMARY PURASHMARY PURASHMARY PURASH

SCALE 1 : 100

1 Floor Plan

SCHEDULE OF AREAS

SITE AREA

LOWER FLOORLIVINGGARAGEALFRESCOPORCHLOWER TOTAL

UPPER FLOORINTERNALBACLONYUPPER TOTAL

TOTAL

sqm

sqmsqmsqmsqmsqm

sqmsqmsqm

sqm

147.438.3

n/an/a

200.4

200.4

n/a

-

12.42.3

REVISION SCHEDULEREVISION SCHEDULEREVISION SCHEDULEREVISION SCHEDULE

1 PRELIMINARY 20.08.13

2 PRELIMINARY[2] 27.08.13

3 PRELIMINARY[3] 08.09.13

A FOR APPROVAL 25.09.13

B GENERAL AMMENDMENTS 03.10.13

DOOR SCHEDULE

NO HEIGHT WIDTH TYPE

D01 2100 4800 2148 Panel Lift Garage Door

D02 2100 820 2100 x 820 External Swing (Entry)

D03 2100 1500 2115 Sliding Glass Door

D04 2100 3000 2130 Sliding Glass Door (4 Panel)

D05 2100 820 2100 x 820 Internal Swing

D06 2100 820 2100 x 820 Internal Swing

D07 2100 820 2100 x 820 Internal Swing

D08 2100 820 2100 x 820 Internal Swing

D09 2100 820 2100 x 820 Internal Swing

D10 2100 720 2100 x 720 Internal Swing

D11 2100 720 2100 x 720 Internal Swing

D12 2100 720 2100 x 720 Internal Swing

D13 2100 720 2100 x 720 Internal Swing

D14 2100 720 2100 x 720 Cavity Sliding Door

D15 2100 1800 2100 x 1800 Sliding Cupboard Door

D16 2100 1800 2100 x 1800 Sliding Cupboard Door

D17 2100 1800 2100 x 1800 Sliding Cupboard Door

D18 2100 1800 2100 x 1800 Sliding Cupboard Door

D19 2100 1800 2100 x 1800 Sliding Cupboard Door

D20 2100 1500 Square Set Opening

WINDOW SCHEDULE

NO HEIGHT WIDTH TYPE

W01 1800 900 1809 Sliding Window

W02 1800 900 1809 Sliding Window

W03 600 1500 0615 Sliding Window

W04 900 1800 0918 Sliding Window

W05 600 1500 0615 Sliding Window

W06 1200 2100 1221 Sliding Window

W07 1200 1800 1218 Sliding Window

W08 1200 900 1209 Double Hung Window

W09 600 1500 0615 Sliding Window

W10 600 2410 0624 Sliding Window

W11 900 1800 0918 Sliding Window

NORTH

Page 5: MARY PURASH LOT 37 ANASTASIA STREET, WEST MACKAY QLD · 2014. 11. 12. · bca, australian standards, relevant supplements & all other relevant authorities. 5. all timber framing to

DOOR

NOTE:

DIMENSIONS SHOWN ARE TO SLABEDGE (OUTER FACE B'WORK)

ALFRESCO SLABASSUMED RL 00.100

HOUSE SLABASSUMED RL 00.250

GROUND LEVELASSUMED RL 00.000

SHR SETDOWN.NOM. 50mm

SHR SETDOWN.NOM. 50mm

GARAGE DOOR

150

SDN DOOR

FALL SLA

B

DOOR

TUB

WC

FW

FW

FWBATH

VB

SHR

SHR

WC VBFW

SK

brick col.

brick col.brick col.

brick col.brick col.

6460

2840

3840

4100

2500

1974

0

350

2150

2030

3170

5140

2540

6900

1978

0

1978

0

600

350

720

800

600 4010 1230 3710 2550

4010 1230 6260

600 600

2550

470 3070 470 1230 350

4010 4940

4010 350 4240 350

8950

1030

7090

0

70 2400

2180 1000

1000

1000

600

project no dwg no rev

scale sizeA3

date

design drawn check approve

title

project

project address

General Note: Builder to check and verify all dimensions, levels,etc. as noted on this/these drawings and be fully aware of anyadditional notes on approved copy of same drawing beforecommencing any setting out of works, ordering of materials,and/or construction work. All works must comply with theBuilding Code of Australia, Australian Standards and all otherrelevant authorities. All work must be carried out in the best oftradesman like manner and to the full satisfaction of the owner

koda design pty ltd6/99 musgrave road red hill qld 4059

acn 137 818 645BDAQ Member No: 1208 BSA License No: 1170922

t (07) 35116446e [email protected] www.kodadesign.com.au

client

Escape Homesp 1300 725 514m 0431 421 181

w escapehomes.com.aue [email protected]

COPYRIGHT: THESE DRAWINGS ARE THE EXCLUSIVE PROPERTY OF KODA DESIGN PTY. LTD. AND MAY NOT BE LOANED OR COPIED IN WHOLE OR PART WITHOUT WRITTEN CONSENTC

BBBB

03.10.13 1 : 100

3/10/2013 7:04:01 AM

3043304330433043 A111A111A111A111

DNP DNP DNP MZ

Slab Setout PlanSlab Setout PlanSlab Setout PlanSlab Setout Plan

PROPOSED RESIDENCEPROPOSED RESIDENCEPROPOSED RESIDENCEPROPOSED RESIDENCE

LOT 37 ANASTASIA STREET

WEST MACKAY QLD

FOR APPROVAL

MARY PURASHMARY PURASHMARY PURASHMARY PURASH

SCALE 1 : 100

1 Slab Setout Plan

LEGEND - SETOUTC1 COLUMN TYPE 1

200sq HWD TIMBER COLUMNC2 COLUMN TYPE 2

STEEL SHS COLUMN (NOM. 90SHS)C3 COLUMN TYPE 3

COLUMN. SIZE AS SHOWNC4 COLUMN TYPE 4

COLUMN. SIZE AS SHOWNFW FLOOR WASTESDN SETDOWNSINK KITCHEN SINKTUB LAUNDRY TUBVB VANITY BASINWC TOILET SUITE

REVISION SCHEDULEREVISION SCHEDULEREVISION SCHEDULEREVISION SCHEDULE

A FOR APPROVAL 25.09.13

B GENERAL AMMENDMENTS 03.10.13

Page 6: MARY PURASH LOT 37 ANASTASIA STREET, WEST MACKAY QLD · 2014. 11. 12. · bca, australian standards, relevant supplements & all other relevant authorities. 5. all timber framing to

A/C INT

A/C EXT

GARAGE DOOR(ceiling mount for panel lift)

RH

DW

UBO

REF

A/C EXT

A/C INT

WP

DIRECT CONNECTFOR UBO/CT

ELEC POWER FIXTURES COUNT

DOUBLE GPO: 19SINGLE GPO: 03TV OUTLETS: 01DATA OUTLETS: 02PHONE OUTLETS: 01

SD

SD

MB

HWS

project no dwg no rev

scale sizeA3

date

design drawn check approve

title

project

project address

General Note: Builder to check and verify all dimensions, levels,etc. as noted on this/these drawings and be fully aware of anyadditional notes on approved copy of same drawing beforecommencing any setting out of works, ordering of materials,and/or construction work. All works must comply with theBuilding Code of Australia, Australian Standards and all otherrelevant authorities. All work must be carried out in the best oftradesman like manner and to the full satisfaction of the owner

koda design pty ltd6/99 musgrave road red hill qld 4059

acn 137 818 645BDAQ Member No: 1208 BSA License No: 1170922

t (07) 35116446e [email protected] www.kodadesign.com.au

client

Escape Homesp 1300 725 514m 0431 421 181

w escapehomes.com.aue [email protected]

COPYRIGHT: THESE DRAWINGS ARE THE EXCLUSIVE PROPERTY OF KODA DESIGN PTY. LTD. AND MAY NOT BE LOANED OR COPIED IN WHOLE OR PART WITHOUT WRITTEN CONSENTC

BBBB

03.10.13 1 : 100

3/10/2013 7:04:02 AM

3043304330433043 A121A121A121A121

DNP DNP DNP MZ

Elec Power LayoutElec Power LayoutElec Power LayoutElec Power Layout

PROPOSED RESIDENCEPROPOSED RESIDENCEPROPOSED RESIDENCEPROPOSED RESIDENCE

LOT 37 ANASTASIA STREET

WEST MACKAY QLD

FOR APPROVAL

MARY PURASHMARY PURASHMARY PURASHMARY PURASH

REVISION SCHEDULEREVISION SCHEDULEREVISION SCHEDULEREVISION SCHEDULE

A FOR APPROVAL 25.09.13

B GENERAL AMMENDMENTS 03.10.13

STANDARD LIGHT, BATTEN HOLDER

1. light switch mount height @ 1250AFFL, uno2. powerpoint mount height @ 300AFFL, uno3. if not stated, provide electrical connection to oven,cooktop, rangehood and dishwasher4. refer general legend for all acronyms not covered inthis legend

F

MS

W

P

D

F

MB

SD

L

LEGEND - GENERAL

LIGHTING

DOWNLIGHT, FLUORO

FLOOD LIGHT

MOTION LIGHT SENSOR

WALL MOUNTED LIGHT

FLUORO BATTEN, 1x1200 LONG

PENDANT LIGHT

FLUORO ROUND LIGHT

LIGHT SWITCH

LIGHT SWITCH, 2 WAY

DIMMER SWITCH

FAN SWITCH, ON / OFF, SPEED

3 in 1 FAN / LIGHT / HEATER

POWER

A/C INT

A/C EXT

SINGLE GPO

DOUBLE GPO

TV OUTLET

PHONE OUTLET

DATA OUTLET

DOUBLE DATA OUTLET

METER BOX

INTERCOM WITH DOOR RELEASE

CEILING FAN

CEILING FAN WITH LIGHT

EXHAUST FAN

A/C UNIT, INTERNAL WALL

A/C UNIT, EXTERNAL

OTHER

SMOKE DETECTOR

SUFFIXES

FACE OF BENCHANY NUMERAL FOLLOWING ANY OFTHE ABOVE ACRONYMS INDICATESHEIGHT OF FIXTURE / FITTING

OVERUNDERWATERPROOF

FB1500*

OUWP

NOTES

SCALE 1 : 100

1 Elec Plan - Power Layout

Page 7: MARY PURASH LOT 37 ANASTASIA STREET, WEST MACKAY QLD · 2014. 11. 12. · bca, australian standards, relevant supplements & all other relevant authorities. 5. all timber framing to

ELEC LIGHTING FIXTURES COUNT

DOWNLIGHT: 30STANDARD LIGHT: 00FLUORO BATTEN: 02FLUORO ROUND: 01WALL LIGHT: 00FLOOD LIGHT: 00EXHAUST FAN: 03CEILING FAN: 06

project no dwg no rev

scale sizeA3

date

design drawn check approve

title

project

project address

General Note: Builder to check and verify all dimensions, levels,etc. as noted on this/these drawings and be fully aware of anyadditional notes on approved copy of same drawing beforecommencing any setting out of works, ordering of materials,and/or construction work. All works must comply with theBuilding Code of Australia, Australian Standards and all otherrelevant authorities. All work must be carried out in the best oftradesman like manner and to the full satisfaction of the owner

koda design pty ltd6/99 musgrave road red hill qld 4059

acn 137 818 645BDAQ Member No: 1208 BSA License No: 1170922

t (07) 35116446e [email protected] www.kodadesign.com.au

client

Escape Homesp 1300 725 514m 0431 421 181

w escapehomes.com.aue [email protected]

COPYRIGHT: THESE DRAWINGS ARE THE EXCLUSIVE PROPERTY OF KODA DESIGN PTY. LTD. AND MAY NOT BE LOANED OR COPIED IN WHOLE OR PART WITHOUT WRITTEN CONSENTC

BBBB

03.10.13 1 : 100

3/10/2013 7:04:03 AM

3043304330433043 A122A122A122A122

DNP DNP DNP MZ

Elec Lighting LayoutElec Lighting LayoutElec Lighting LayoutElec Lighting Layout

PROPOSED RESIDENCEPROPOSED RESIDENCEPROPOSED RESIDENCEPROPOSED RESIDENCE

LOT 37 ANASTASIA STREET

WEST MACKAY QLD

FOR APPROVAL

MARY PURASHMARY PURASHMARY PURASHMARY PURASH

REVISION SCHEDULEREVISION SCHEDULEREVISION SCHEDULEREVISION SCHEDULE

A FOR APPROVAL 25.09.13

B GENERAL AMMENDMENTS 03.10.13

STANDARD LIGHT, BATTEN HOLDER

1. light switch mount height @ 1250AFFL, uno2. powerpoint mount height @ 300AFFL, uno3. if not stated, provide electrical connection to oven,cooktop, rangehood and dishwasher4. refer general legend for all acronyms not covered inthis legend

F

MS

W

P

D

F

MB

SD

L

LEGEND - GENERAL

LIGHTING

DOWNLIGHT, FLUORO

FLOOD LIGHT

MOTION LIGHT SENSOR

WALL MOUNTED LIGHT

FLUORO BATTEN, 1x1200 LONG

PENDANT LIGHT

FLUORO ROUND LIGHT

LIGHT SWITCH

LIGHT SWITCH, 2 WAY

DIMMER SWITCH

FAN SWITCH, ON / OFF, SPEED

3 in 1 FAN / LIGHT / HEATER

POWER

A/C INT

A/C EXT

SINGLE GPO

DOUBLE GPO

TV OUTLET

PHONE OUTLET

DATA OUTLET

DOUBLE DATA OUTLET

METER BOX

INTERCOM WITH DOOR RELEASE

CEILING FAN

CEILING FAN WITH LIGHT

EXHAUST FAN

A/C UNIT, INTERNAL WALL

A/C UNIT, EXTERNAL

OTHER

SMOKE DETECTOR

SUFFIXES

FACE OF BENCHANY NUMERAL FOLLOWING ANY OFTHE ABOVE ACRONYMS INDICATESHEIGHT OF FIXTURE / FITTING

OVERUNDERWATERPROOF

FB1500*

OUWP

NOTES

SCALE 1 : 100

1 Elec Plan - Lighting Layout

Page 8: MARY PURASH LOT 37 ANASTASIA STREET, WEST MACKAY QLD · 2014. 11. 12. · bca, australian standards, relevant supplements & all other relevant authorities. 5. all timber framing to

project no dwg no rev

scale sizeA3

date

design drawn check approve

title

project

project address

General Note: Builder to check and verify all dimensions, levels,etc. as noted on this/these drawings and be fully aware of anyadditional notes on approved copy of same drawing beforecommencing any setting out of works, ordering of materials,and/or construction work. All works must comply with theBuilding Code of Australia, Australian Standards and all otherrelevant authorities. All work must be carried out in the best oftradesman like manner and to the full satisfaction of the owner

koda design pty ltd6/99 musgrave road red hill qld 4059

acn 137 818 645BDAQ Member No: 1208 BSA License No: 1170922

t (07) 35116446e [email protected] www.kodadesign.com.au

client

Escape Homesp 1300 725 514m 0431 421 181

w escapehomes.com.aue [email protected]

COPYRIGHT: THESE DRAWINGS ARE THE EXCLUSIVE PROPERTY OF KODA DESIGN PTY. LTD. AND MAY NOT BE LOANED OR COPIED IN WHOLE OR PART WITHOUT WRITTEN CONSENTC

BBBB

03.10.13 1 : 100

3/10/2013 7:04:04 AM

3043304330433043 A131A131A131A131

DNP DNP DNP MZ

Framing & BracingFraming & BracingFraming & BracingFraming & Bracing

Plan (refer eng.)Plan (refer eng.)Plan (refer eng.)Plan (refer eng.)

PROPOSED RESIDENCEPROPOSED RESIDENCEPROPOSED RESIDENCEPROPOSED RESIDENCE

LOT 37 ANASTASIA STREET

WEST MACKAY QLD

FOR APPROVAL

MARY PURASHMARY PURASHMARY PURASHMARY PURASH

SCALE 1 : 100

1 Framing & Bracing Plan (refer eng.)

REVISION SCHEDULEREVISION SCHEDULEREVISION SCHEDULEREVISION SCHEDULE

A FOR APPROVAL 25.09.13

B GENERAL AMMENDMENTS 03.10.13

Page 9: MARY PURASH LOT 37 ANASTASIA STREET, WEST MACKAY QLD · 2014. 11. 12. · bca, australian standards, relevant supplements & all other relevant authorities. 5. all timber framing to

LOWER FLOOR0

LOWER FLOOR0

LOWER CEILING2440

LOWER CEILING2440

'COLORBOND CUSTOMORB' METALSHEET ROOFING AT 20° PITCH

SELECTED COLORBONDFASCIAS & GUTTERS

ALUMINIUM FRAME WINDOW &DOOR SUITES TYPICAL

RENDERED BRICKWORKTYPICAL EXTERNAL FINISH

D01 NOTE:RL'S TO BE CONFIRMED.

CONFIRM ON SITE

D02/1.8 0.9 SWW01

/1.8 0.9 SWW02

FEATURE BRICK COLUMNS.CLADDING AS SELECTED.NOM. STONE CLADDING

LOWER FLOOR0

LOWER FLOOR0

LOWER CEILING2440

LOWER CEILING2440

'COLORBOND CUSTOMORB' METALSHEET ROOFING AT 20° PITCH

SELECTED COLORBONDFASCIAS & GUTTERS

ALUMINIUM FRAME WINDOW &DOOR SUITES TYPICAL RENDERED BRICKWORK

TYPICAL EXTERNAL FINISH

/1.2 1.8 SWW07

D04

LOWER FLOOR0

LOWER FLOOR0

LOWER CEILING2440

LOWER CEILING2440

FC CLADDING WITH TIMBER BATTENCOVER STRIPS ON STUD FRAME TOBUILT OUT UNDER EAVES SECTION'COLORBOND CUSTOMORB' METAL

SHEET ROOFING AT 20° PITCH

SELECTED COLORBONDFASCIAS & GUTTERS

ALUMINIUM FRAME WINDOW &DOOR SUITES TYPICALRENDERED BRICKWORK

TYPICAL EXTERNAL FINISH60/60/60 FIRE RATED WALL

(BOUNDARY WALL)RENDER FINISH

/0.9 1.8SWW11

/0.6 2.4SWW10

/0.6 1.5SWW09

/1.2 0.9DHW08

LOWER FLOOR0

LOWER FLOOR0

LOWER CEILING2440

LOWER CEILING2440

FC CLADDING WITH TIMBER BATTENCOVER STRIPS ON STUD FRAME TOBUILT OUT UNDER EAVES SECTION'COLORBOND CUSTOMORB' METAL

SHEET ROOFING AT 20° PITCH

SELECTED COLORBONDFASCIAS & GUTTERS

ALUMINIUM FRAME WINDOW &DOOR SUITES TYPICAL

RENDERED BRICKWORKTYPICAL EXTERNAL FINISH

D03/0.6 1.5SWW03

/0.9 1.8SWW04

/0.6 1.5SWW05

/1.2 2.1SWW06

project no dwg no rev

scale sizeA3

date

design drawn check approve

title

project

project address

General Note: Builder to check and verify all dimensions, levels,etc. as noted on this/these drawings and be fully aware of anyadditional notes on approved copy of same drawing beforecommencing any setting out of works, ordering of materials,and/or construction work. All works must comply with theBuilding Code of Australia, Australian Standards and all otherrelevant authorities. All work must be carried out in the best oftradesman like manner and to the full satisfaction of the owner

koda design pty ltd6/99 musgrave road red hill qld 4059

acn 137 818 645BDAQ Member No: 1208 BSA License No: 1170922

t (07) 35116446e [email protected] www.kodadesign.com.au

client

Escape Homesp 1300 725 514m 0431 421 181

w escapehomes.com.aue [email protected]

COPYRIGHT: THESE DRAWINGS ARE THE EXCLUSIVE PROPERTY OF KODA DESIGN PTY. LTD. AND MAY NOT BE LOANED OR COPIED IN WHOLE OR PART WITHOUT WRITTEN CONSENTC

BBBB

03.10.13 1 : 100

3/10/2013 7:04:07 AM

3043304330433043 A201A201A201A201

DNP DNP DNP MZ

ElevationsElevationsElevationsElevations

PROPOSED RESIDENCEPROPOSED RESIDENCEPROPOSED RESIDENCEPROPOSED RESIDENCE

LOT 37 ANASTASIA STREET

WEST MACKAY QLD

FOR APPROVAL

MARY PURASHMARY PURASHMARY PURASHMARY PURASH

REVISION SCHEDULEREVISION SCHEDULEREVISION SCHEDULEREVISION SCHEDULE

A FOR APPROVAL 25.09.13

B GENERAL AMMENDMENTS 03.10.13

SCALE 1 : 100

1 Elevation 1 - South West

SCALE 1 : 100

2 Elevation 2 - North East

SCALE 1 : 100

3 Elevation 3 - South East

SCALE 1 : 100

4 Elevation 4 - North West

Page 10: MARY PURASH LOT 37 ANASTASIA STREET, WEST MACKAY QLD · 2014. 11. 12. · bca, australian standards, relevant supplements & all other relevant authorities. 5. all timber framing to

LOWER FLOOR0

LOWER FLOOR0

LOWER CEILING2440

LOWER CEILING2440

(floor leve

l to soffit lining)

2140

FLUSH PLASTERBOARDCEILING TYPICAL

SELECTED METAL SHEETROOFING AT 20° PITCH

SELECTED COLORBOND FASCIAS,GUTTERS & DOWNPIPES

6mm FC SOFFIT LINING

TIMBER ROOF TRUSS AS PERMANUFACTURER'S DETAILS

FLOOR FINISHES ASSELECTED. REFER PLAN

PLASTERBOARD WALLLINING TYPICAL

CONCRETE SLAB & FOOTINGS AS PER ENG'SDWGS. REFER FLOOR PLAN FOR FINISHES

NOTE: TERMITE PROTECTION BY BUILDER,TO BE IN ACCORDANCE WITH AS3660.

GROUND LEVEL NOM.225mm BELOW SLAB LEVEL

NOTE: ENSURE ADEQUATE HEAD ROOM FORSOFFIT LINING. 600mm EAVES AT 20 PITCHLEAVES NOMINAL 2140mm MINIMUM FLOOR LEVELTO SOFFIT, ALLOWING FOR 2130mm HEAD HEIGHT

project no dwg no rev

scale sizeA3

date

design drawn check approve

title

project

project address

General Note: Builder to check and verify all dimensions, levels,etc. as noted on this/these drawings and be fully aware of anyadditional notes on approved copy of same drawing beforecommencing any setting out of works, ordering of materials,and/or construction work. All works must comply with theBuilding Code of Australia, Australian Standards and all otherrelevant authorities. All work must be carried out in the best oftradesman like manner and to the full satisfaction of the owner

koda design pty ltd6/99 musgrave road red hill qld 4059

acn 137 818 645BDAQ Member No: 1208 BSA License No: 1170922

t (07) 35116446e [email protected] www.kodadesign.com.au

client

Escape Homesp 1300 725 514m 0431 421 181

w escapehomes.com.aue [email protected]

COPYRIGHT: THESE DRAWINGS ARE THE EXCLUSIVE PROPERTY OF KODA DESIGN PTY. LTD. AND MAY NOT BE LOANED OR COPIED IN WHOLE OR PART WITHOUT WRITTEN CONSENTC

BBBB

03.10.13 1 : 50

3/10/2013 7:04:08 AM

3043304330433043 A301A301A301A301

DNP DNP DNP MZ

Typical Section A-ATypical Section A-ATypical Section A-ATypical Section A-A

PROPOSED RESIDENCEPROPOSED RESIDENCEPROPOSED RESIDENCEPROPOSED RESIDENCE

LOT 37 ANASTASIA STREET

WEST MACKAY QLD

FOR APPROVAL

MARY PURASHMARY PURASHMARY PURASHMARY PURASH

REVISION SCHEDULEREVISION SCHEDULEREVISION SCHEDULEREVISION SCHEDULE

A FOR APPROVAL 25.09.13

B GENERAL AMMENDMENTS 03.10.13

SCALE 1 : 50

1 Typical Cross Section A-A

Page 11: MARY PURASH LOT 37 ANASTASIA STREET, WEST MACKAY QLD · 2014. 11. 12. · bca, australian standards, relevant supplements & all other relevant authorities. 5. all timber framing to

project no dwg no rev

scale sizeA3

date

design drawn check approve

title

project

project address

General Note: Builder to check and verify all dimensions, levels,etc. as noted on this/these drawings and be fully aware of anyadditional notes on approved copy of same drawing beforecommencing any setting out of works, ordering of materials,and/or construction work. All works must comply with theBuilding Code of Australia, Australian Standards and all otherrelevant authorities. All work must be carried out in the best oftradesman like manner and to the full satisfaction of the owner

koda design pty ltd6/99 musgrave road red hill qld 4059

acn 137 818 645BDAQ Member No: 1208 BSA License No: 1170922

t (07) 35116446e [email protected] www.kodadesign.com.au

client

Escape Homesp 1300 725 514m 0431 421 181

w escapehomes.com.aue [email protected]

COPYRIGHT: THESE DRAWINGS ARE THE EXCLUSIVE PROPERTY OF KODA DESIGN PTY. LTD. AND MAY NOT BE LOANED OR COPIED IN WHOLE OR PART WITHOUT WRITTEN CONSENTC

BBBB

03.10.13

3/10/2013 7:04:11 AM

3043304330433043 A401A401A401A401

DNP DNP DNP MZ

3d Overview 13d Overview 13d Overview 13d Overview 1

PROPOSED RESIDENCEPROPOSED RESIDENCEPROPOSED RESIDENCEPROPOSED RESIDENCE

LOT 37 ANASTASIA STREET

WEST MACKAY QLD

FOR APPROVAL

MARY PURASHMARY PURASHMARY PURASHMARY PURASH

REVISION SCHEDULEREVISION SCHEDULEREVISION SCHEDULEREVISION SCHEDULE

A FOR APPROVAL 25.09.13

B GENERAL AMMENDMENTS 03.10.13