  • Manufacturing / Fabrication Hospitals & Health Care Facilities Fireproofing Residential/Commercial Retail / Commercial Facilities Food & Beverage Processing Maintenance Oil & Gas Water & Wastewater Facilities Industries Served Services Offered Project Inspection Coating Recommendation Failure Analysis Free Technical Service Job Site Training Specification Writing Danny Janulek Idaho, Nevada & Northern California (650) 622-6509 [email protected] [email protected] Steve Sexton Northern & Central California (925) 984-5036 [email protected]@kellymoore.com Greg Sutton Texas, Oklahoma & Arkansas (918) 625-2538 [email protected]@kellymoore.com Trusted and preferred by professionals since 1946 we are known for our commitment to quality, performance and consistency.
  • Slide 3
  • Contego Passive Fire Barrier (PFB)
  • Slide 4
  • 1.(SFRM) Spray Applied Fire Resistive Material 2.(PFB) Passive Fire Barriers 3.(PFP) Passive Fire Protection (UL1709)
  • Slide 5
  • Monokote Monokote is a gypsum based cementitious spray-applied fire resistive material for structural steel framed buildings The term cementitious as defined by ASTM or Underwriters Laboratories Inc. applies to all fireproofing that is wet mixed and then pumped as a slurry. Cementitious does not refer to portland cement content.
  • Slide 6
  • There are two basic categories of Architectural Fireproofing, Residential and Commercial applications. These products usually consist of a thin-film latex or solvent based material.
  • Slide 7
  • There are two basic types of industrial fireproofing cementitious and epoxy intumescent. These products are usually designed to meet UL1709 Cementitious fireproofing is a cement-based material that provides fire protection through its inherent insulative properties. Epoxy intumescent fireproofing has the appearance and application characteristics of a protective coating.
  • Slide 8
  • Materials including structural steel, aluminum, dimensional lumber, manufactured wood products, trusses, drywall, spray polyurethane foam insulation, HDPE wall panels, concrete, plaster, solid core doors and more. The product may also be used for conduit, decking and cladding.
  • Slide 9
  • Intumescent Fireproofing Systems allow designers to express the steel structure as an art form in buildings where fire resistance ratings are required. Project planners now have flexibility to create unique exposed steel designs where fire resistance ratings are required, with aesthetically pleasing, durable and cost effective alternatives.
  • Slide 10
  • Decorative Thin Film Coating 1, 2 and 3 Hour Fire Ratings 0 V.O.C. /Non-Toxic Excellent Durability High Impact Strength Provides A Clean Dust Free Environment Easy Paint-Like Application Suitable For Top coating with any KM Paint Marketable to our Painting Contractors Direct Manufacturer Support
  • Slide 11
  • Tested to 9 ASTM International Standards: ASTM D 1475 - Standard Test Method For Density of Paint, Varnish, Lacquer, and Related Products. ASTM D 2369 - Standard Test Method For Volatile Content of Coatings. ASTM D 3359 - Standard Methods for Measuring Adhesion by Tape Test (Methods A and B) ASTM D 3960 - Standard Practice for Determining Volatile Organic Compound (VOC) Content of Paints and Related Coatings. ASTM D 4017 - "Standard Test Method for Water in Paints and Paint Materials by Karl Fischer Method. ASTM E 84 - Standard Test Method for Surface Burning Characteristics of Building Materials. ASTM E 119 - Standard Test Methods for Fire Tests of Building Construction and Materials. ASTM E 283 - Standard Test Method for Determining Rate of Air Leakage Through Exterior Windows, Curtain Walls, and Doors Under Specified Pressure Differences Across the Specimen. ASTM E 662 - Standard Guide for Measurement of Gases Present or Generated During Fires.
  • Slide 12
  • ONE HOUR PROTECTION 1 HOUR RATINGS W Shapes - Wide Flange Beams and ColumnsTotal DFTCoverageRequiredMinimum Linear Ft.Square Ft.Mils(Sq. Ft./Gal.)GallonsCoats Section*W/D**ft.2/ft W12x220.5603.28384.001259.52 6415.0083.973 W12x160.4103.251178.003828.50 8810.91350.954 Sub Tot434.91 L Shapes - Angles Total DFTCoverageRequiredMinimum Linear Ft.Square Ft.Mils(Sq. Ft./Gal.)GallonsCoats Section*W/D**ft.2/ft L6x6x1/20.8241.98510.001009.80 2243.6423.141 L5x3x1/40.4181.3292.00121.44 4322.335.442 L4x4x3/80.6151.3261.0080.52 2933.102.432 L4x4x1/40.4161.3266.0087.12 4322.333.902 L3x3x3/80.6080.98142.00139.59 3032.004.362 L3x3x1/40.4140.98526.00517.06 4421.8223.702 497.89 TOTAL Firefilm 722 gallons
  • Slide 13
  • Sample thickness required for 2 Hour application. Beam TypeAlbi-CladContego W10x49 310 mils77 mils HSS 8x8x.500 334 mils42 mils Winner!!
  • Slide 14
  • Sample thickness required for 2 Hour application: Beam TypeFIREFILMCONTEGO W10x49 N ot possible (Design X641)77 mils HSS 8x8x.500 186 mils (Design X642) 42 mils Winner! A/D Firefilm III