Mesotherapy InstrumentINSTRUCTION

Dear Customer,Thanks for your choosing our products, for the best capability and safety, please read the manual before operation.

Page 2: Manual Equipo de Mesoterapia

Please reserve the manual for your reference.

Page 3: Manual Equipo de Mesoterapia

Content

Operation

Page 4: Manual Equipo de Mesoterapia

Taboo

Brief Introduction

Needle-free injection is high-effect,woundless and safe treatment,completely removes the traditional meddle and microneedle injection.It uses the electroporation and electroosmosis, to supply nutrition to the deep-seated cells,lymph drainage, promote metabolism,lymph and blood circulation, so as to decrease wrinkles,whiten skin and keep moisture,improve cellulite,quicken fat dissolving and weight loss . Comparing it with the single skin care products,effectively absorb products much higher,throughly solve the

Page 5: Manual Equipo de Mesoterapia

problems of products only staying at epidermis,shorten the period of treatment.Work TheoryIt uses Electroporation and Electroosmasis techniques,without any injectors,easily opens the aquaporin(AQP),transports skin wanted mutrition,so as to treat all kinds of skin problems.Let the nurtrition quickly being absorbed and effective,promote skin metabolism ,keep skin elastic and fine.AQP is the main channel of water in and out of the cells.What is the electroporation and electroosmosis? Electroporation: Directly act on the skin, instantly enhance skin tissue penetration. Under the function of electroshock, there will be formed holes in the lipid mobilizationof cells, at the same time, the hydrophile molecule which have not been absorbed originally can penetrate into cells inner. Once the holes forming, withing several seconds to several minutes, it will keep the opening state according to the lenth of electroshock. Electroosmosis: Mainly act on the substance molecule which will be dispersed, help it freely to penetrate into skin inner. Same quality electric charges are mutual repulsion, so it can throw positive current onto positive nutrition molecule, push untritin molecule into skin tissues.Brief Introduction

At the same time, the neutral molecule also will penetrate into skin inner also.

Function:Freckle removal and skin whitening: Open cells channel woundless, obsorb nutrition, participate in cells metabolism, promote cells rebirth.

Page 6: Manual Equipo de Mesoterapia

Fantasy wrinkle removal:The electrode nutrition is directly penetrated the deep-seated skin, start cells rebirth, remove wrinkles of deep skin layer. Resist the acne: Through the electric nutrition conveyer belt, inject the acne removal distillate into the focus, clear or restrain the acne rebirth, avoid the wound infection. Moisten and make up water: Inject the water feeding active distillate into the deep-seated skin, supply enough water to the cells, prevent the series of skin problems caused by short of water.Comparasion of Before and After

After Before

After Before

After Before

Page 7: Manual Equipo de Mesoterapia

Control Panel

1.swift to other function 2.start/pause3.function confirmation4.switch of the machine5-6.parameter adjustment7.display

MESO THERAPY INSTRUMENT

Page 8: Manual Equipo de Mesoterapia

Spare parts connection

Connect to the mainframe Screw it

Connect to the mainframe Screw it

Cold hammer probe connection

Screw it Connect to the mainframe

Ultrasonic probe connection

Mesoterapy probe(body) connection

Mesotherapy probe(face)connection

Page 9: Manual Equipo de Mesoterapia

Connect to the mainframe Screw it

Page 10: Manual Equipo de Mesoterapia

1.Start the machine by (No.4)

2.Press (NO .1)to select the function

Uitrasonic Cold hammer

Mesotherapy(B) Mesotherapy(F)

3.Press to (NO.2) to adjust the state,intensity and time.

State:offIntensity:01Time:30:00

4.Press (NO.1) to switch from state,intensity and time.

5.Set the state by (NO.2)

6.Set the intensity and time by (NO.5.6)

7.Press (NO.2) back to choose other functions.Operation

1.Check and analyzer the parts need to be cared2.Choose the appropriate skin care products.

3.Ultrasonic care spare part

1)Apply the skin care products on the treated parts

2 Choose the ultrasonic function as picture

Operation

Page 11: Manual Equipo de Mesoterapia

Uitrasonic Cold hammer

Mesotherapy(B) Mesotherapy(F)

3 Set each parameter as follows: State On time 05

Intensity 08 (you can adjust it according to different customers)

State:onIntensity:05Time:08

4 Move the probe as words 'O'or 'Z'

4. Mesotherapy(face) spare part--- 1)Apply the skin care products on the treated parts.

2)Choose the Mestherapy (face)function.(as picture)Uitrasonic Cold hammer

Mesotherapy(B) Mesotherapy(F)

Note: when use mesotherapy probe the Beautician should use one hand to hold the probe and the other hand touch the part where is operated on in order to create pathway for micro eletricity .

3)Set each parameter as follows:

State: on

Page 12: Manual Equipo de Mesoterapia

Time: 05 Intensity: 03 (can be adjusted according to different customers)

Frequency:20Hz (can be adjusted according to different customers)

State:onIntensity:03Frequency:20HzTime:05

4).Move the probe as number '8

(From chin to forehead)

5. Cooling treatment (spare part-- )

1) Choose the cold hammer function(as picture)Uitrasonic Cold hammer

Mesotherapy(B) Mesotherapy(F)

Operation

2).Set each parameter as follows: State:on Time:05 Intensity:10 (can be adjusted according to different customers)

State:onIntensity:10Time:05

Operation

Page 13: Manual Equipo de Mesoterapia

State:on

Intensity:08Time:05

3) Move the probe as number 8

(From chin to forehead)1.Check and analyze the parts need to be cared.2.Choose the appropriate skin care products.

3.Ultrasonic care (spare part )

1). Apply the skin care products on the treated parts2). Choose the ultrasonic function (as picture)

Uitrasonic Cold hammer

Mesotherapy(B) Mesotherapy(F)

3).Set each parameter as follows: State:on Time:05 Intensity: 08

Page 14: Manual Equipo de Mesoterapia

4).Move the probe with circle as picture

4. Mesotherapy(body) spare part--

1). Pure the skin care products into the probe:

Operation

Page 15: Manual Equipo de Mesoterapia

Take out the bottle capPut the skin care products into the bottle

2).Choose the Mesotherapy (for body)function.Uitrasonic Cold hammer

Mesotherapy(B) Mesotherapy(F)

3).Set each parameter as follows:

State:On Time:05

Intensity:08(can be adjusted according to different customers) Frequency:20Hz

Operation

Screw out the glass bottleStep1:Screw the golden part

Page 16: Manual Equipo de Mesoterapia

State:on

Intensity:08Frequency:20HzTime:05

4).Move the probe with circle as picture

5.Cooling treatment (spare part-- )

1).Choose the Cold pore hammer functionUitrasonic Cold hammer

Mesotherapy(B) Mesotherapy(F)2).Set each parameter as follows: State:on

Time:05 Intensity: 10(can be adjusted according to different customers)

State:onIntensity:10Time:05

Operation

Page 17: Manual Equipo de Mesoterapia

1.Check and analyze the parts need to be treated.2.Choose the appropriate skin care products.

3. Ultrasonic care ( spare part )

1).Apply the skin care products on the treated parts.2).Choose the ultrasonic function

Uitrasonic Cold hammer

Mesotherapy(B) Mesotherapy(F)

Operation

Page 18: Manual Equipo de Mesoterapia

Operation

3).Set each parameter as follows:

State:on Time:05

Intensity:08(can be adjusted according to different customers)

State:onIntensity:08Time:05

4).Move the probe as picture

4.Mesotherapy ( spare part- )

1).Put the skin care products in to the probe.

Screw out the glass bottle

Put the skin care products into the bottle

Take out the bottle cap

Operation

Step1:Screw the golden part

Page 19: Manual Equipo de Mesoterapia

1 Choose the Mesotherapy(B) functionUitrasonic Cold hammer

Mesotherapy(B) Mesotherapy(F)

2). Set each parameter as follows:

State: On Time: 05

Intensity:08 Frequency:20Hz

State:on

Intensity:08Frequency:20HzTime:30:00

3).Move the probe as follows:

5. Cooling treatment (spare part--- )

1).Choose the cold hammer functionUitrasonic Cold hammer

Mesotherapy(B) Mesotherapy(F) 2). Set each parameter as follows:

State: On Time:05

Intensity:10(can be adjusted according to different customers)

Page 20: Manual Equipo de Mesoterapia

Operation

State:on

Intensity:10Time:05

3).Apply the skin care products on the treated skin.4). Move the probe as picture:

Taboo:1. People with allergic skin

2. Skin with wound without recovery3. There is any medical equipment in body

4.Pregnant woman5.People with mental disease

Operation

Page 21: Manual Equipo de Mesoterapia

Solution for simple malfunction

Gross Weight:30kg table

type

Voltage AC110V 230V 240V

Frequency: 5 Power:

Meas:54*40*23cm

stand type

Check whether power switch is on

connectionCheck whether power is in right

replace another one Check whether fuse is broken, if so

right condition (by technician)Check if the power supply is in

power off and cool in a natural wayUsed for too long a time, need to

connection with the machine Check if the probe is in good

during operationMachine is over heating

No output

Meas:106*55*46.5cm

Power:

Frequency: 5

240V 230V 220VAC110VVoltage

No power

Power on, no reponse

SolutionMalfunction

220V

Page 22: Manual Equipo de Mesoterapia

Gross Weight:7.5kgPacking List

Name Unit Qty Remark

Mainframe Set 1

Ultrasonic probe Piece 1

Mesotherapy probe(face) Piece 1

Clod hammer Piece 1

Mesotherapy probe(body) Piece 1

Accessories shelf Piece 1

Power wire Strip 1

Fuse Piece 2

User manual Piece 1

Important Safety Notice

1.Please don't disassemble the equipment or try to do some other operation, which have been indicated in our instruction. All the repairing work should be done by our admitted professional personnel.

2.Please don't assemble or operate this equipment while you are near the water or your hands are wet. Notice that don't pour the liquid on it.

Page 23: Manual Equipo de Mesoterapia

3.Please pull out the plug from the socket when you met such conditions as below. And keep in touch with professional maintenance Station.

A.The equipment touched liquid B.The equipment has abnormal smell, smoking or loud and strong noise. C.Cable is brokenD.The equipment is fallen down and broken

4.Please don't put anything on the cables, don't place the equipment at any place where someone can step on the cable.

5.Please pull out the power cable after using it for your safety6.Don't put anything into the equipment's jack, otherwise it may

cause fire or touch the electricity. If something enters the equipment, please don't pick it out by yourself, contract distributor or our company immediately

7.Please don't put the equipment on the anything that can't stand steadily, avoid it turns over and damage.

8.Our company reserves the right to modify the information in this introduction before notify! And keep the explanations right for the above.