Manual de usuario
STF100
REF. 4464
4 Generalsafetyinstructions
4 Types of notices
5 Basic safety instructions
6 Introduction
6 General description
7 General use of the headend
8 Basicinstallationandconfiguration
8 Assembly, connection of signals and power supply
9 Description of the user interface
10 IKUNET bus configuration
15 Configuration of general parameters
16 Module configuration
21 Service Management
24 Advancedfunctions
24 Save/Restore Function
24 Internet Access
25 Network functions
26 Advanced global transport processing
27 Reports
31 CECertificate
31 STF-201
Contents
4
General safety instructionsJJ ReadJallJofJthisJuserJmanualJcarefullyJbeforeJpluggingJinJtheJunit.
JJ AlwaysJhaveJtheseJinstructionsJtoJhandJduringJinstallation.
JJ FollowJallJofJtheJinstructionsJandJsafetyJnoticesJregardingJunitJhandling.
Types of noticesTheJmeaningJofJtheJsafetyJnoticesJusedJinJthisJmanualJareJdescribedJbelow.
DANGER of DEATH oR INJURY
ThisJsafetyJnoticeJindicatesJaJpossibleJdangerJforJtheJlifeJandJhealthJofJpeople.JNotJfollowingJtheseJinstructionsJmayJleadJtoJseriousJconsequencesJtoJhealthJandJmayJevenJcauseJfatalJinjuries.
RISK of DAmAGE To THE UNIT
ThisJsafetyJnoticeJindicatesJaJpossibleJdangerousJsituation.JNotJfollowingJtheseJinstructionsJmayJleadJtoJtheJunitJbeingJdamaged.
NoTE
ThisJtypeJofJnoticeJisJaJnoteJcontainingJapplicableJadviceJandJusefulJinformationJforJoptimumJuseJofJtheJunit.
HANDLING THE INSIDE of THE UNIT IS foRBIDDEN
ThisJnoticeJforbidsJanyJworkJthatJmayJaffectJtheJworkingJorderJofJtheJunitJorJitsJwarranty.
Do NoT DISPoSE of AS URBAN WASTE
ThisJtypeJofJnoticeJindicatesJthatJtheJunitJmustJnotJbeJdisposedJofJasJunselectedJurbanJwaste.
DANGER
ATTENTION
General safety instructions/Basic safety instructions
5
Basic safety instructions
DANGER of DEATH oR INJURY
JJ DoJnotJinstallJtheJunitJduringJanJelectricalJstorm.JThisJcouldJleadJtoJelectro-staticJdischargeJfromJlightning.
JJ DoJnotJopenJtheJunit.JThereJisJaJriskJofJelectrostaticJdischarge.
RISK of DAmAGE To THE UNIT
JJ TheJunitJmustJbeJappropriatelyJventilated.JInstallJtheJunitJinJaJdust-freeJlocation.JDoJnotJplaceJtheJunitJinJaJlocationJwhereJtheJventilationJslotsJareJcoveredJorJblocked.JInstallJtheJunitJinJaJlocationJwithJatJleastJ20JcmJaroundJitJfreeJofJotherJobjects.
JJ DoJnotJexposeJtheJunitJtoJrainJorJmoisture.JInstallJtheJequipmentJinJaJdryJlo-cationJwithJnoJinfiltrationJorJcondensationJofJwater.JShouldJaJliquidJenterJtheJunit,JdisconnectJitJimmediatelyJfromJtheJmains.
JJ KeepJtheJunitJawayJfromJflammableJobjects,JcandlesJandJanythingJthatJmayJcauseJaJfire.
JJ ConnectJtheJunitJtoJanJeasilyJaccessibleJpowerJsocket.JInJtheJeventJofJanJemergency,JitJwillJthenJbeJpossibleJtoJquicklyJunplugJtheJunit.
JJ DoJnotJexposeJtheJunitJtoJsourcesJofJheatJ(sun,Jheating,Jetc.).
DANGER
ATTENTION
EN
Introduction/General description
6
IntroductionJJ ToJensureJtheJcorrectJuseJandJinstallationJofJtheJheadend,JitJisJnecessaryJtoJreadJtheJ
userJandJtroubleshootingJprocedureJmanualsJcorrespondingJtoJtheJcompleteJsolutionJ("DigitalJTVJforJhotels")JandJtoJeachJofJtheJindividualJmodules.
JJ IKUSIJreservesJtheJrightJtoJmodifyJtheJcontentsJofJthisJmanualJwithoutJpriorJwarning.
General description
TheJheadendJdescribedJinJthisJmanualJisJmadeJupJofJtheJfollowingJmodules:
JJ STF-100J(Ref.J4465):JDVB-S/S2JtoJDVB-TJtransmodulatorJ(QPSK/8PSKJtoJCOFDM).
JJ CFP-507J(Ref.J4439):JpowerJsupplyJ+12JV/+24JV.
4
5
6
7
1
2
3
8
9
10
11
12
13
14
15STF-100
KEY
A STF-100Jmodule
B CFP-700Jmodule
C CFP-507Jmodule
1 DVB-S/S2JchannelJinput
2 LoopJoutput
3 LNBJremoteJpowerJsupply
4 DB-9Jport
5 DCJpowerJsupply
6 RJ-45JportsJforJIKUNETJbus
7 CouplingJloopJDVB-TJoutput
8 OutputJ+12JVJ(5JA)
9 OutputJ+24JVJ(60JmA)
10 OutputJ+18JV/22JkHzJ(300 mA)
11 OutputJ+13JV/22JkHzJ(300 mA)
12 OutputJ+18JV/0JkHzJ(300 mA)
13 OutputJ+13JV/0JkHzJ(300 mA)
14 OutputJ+12JVJ(7JA)
15 OutputJ+24JVJ(60JmA)
7
Introduction/General use of the headend
7
JJ CFP-700J(Ref.J4401):JpowerJsupplyJ+12JV/+24JVJforJselectionJofJpolarisation.
JJ BAS-900J(Ref.J4411):Jbase-supportJwithJcapacityJforJ9JmodulesJ(dimensions:J563x257x24Jmm).
JJ MS-0504J(Ref.J1023):Jstand-aloneJmultiswitchJ(4JSATJinputsJandJ4Joutputs).
NoTE
PleaseJreadJtheJdetailedJinformationJinJtheJmanualsJforJtheJmodulesJincludedJinJtheirJrespectiveJpackaging.
General use of the headendThisJheadendJisJdesignedJforJtheJemissionJofJDVB-TJ(COFDM)JsignalsJfromJtheJinputJofJfreeJorJencryptedJDVB-S/S2JsignalsJ(QPSK/8PSKJtoJCOFDM).
NoTE
TheJDVB-TJ(COFDM)JoutputJsignalJrequiresJaJtrunkJamplifierJforJtheJcorrectJdistri-butionJinJinstallationsJforJaJlargeJnumberJofJsockets.
ENEN
Basic installation and configuration/Assembly, connection of signals and power supply
8
Basic installation and configurationNoTE
AJPCJwithJanJEthernetJnetworkJcardJandJaJCAT-5EJEthernetJcrossoverJcableJareJrequiredJforJcommunicationJwithJtheJheadend.
NoTE
ToJdisplayJtheJgraphicsJprovidedJinJtheJheadendJconfigurationJprogramJcorrectly,JweJrecommendJinstallingJtheJMozillaJFirefoxJwebJbrowserJ(www.mozilla.com)JinJtheJcontrolJPC.
Assembly, connection of signals and power supply
1) AttachJtheJmodulesJtoJtheJbaseJoneJbyJoneJfollowingJtheJinstructionsJgivenJinJtheJmanualsJforJeachJmodule.
NoTE
IKUSIJrecommendsJtheJmodulesJareJassembledJinJtheJorderJshownJinJtheJaboveJfigure:
JJ Right:JCFP-700/CFP-507JpowerJsupplies.
JJ Left:JSTF-100JtransmodulatorsJ
JJ LastJSTF-100JonJtheJright:JMasterJSTF-100JwithJDVB-TJoutputJsignal.
13
2
654
KEY
1 DVB-S/S2JsignalJinput
2 DVB-TJsignalJoutput
3 BridgingJlineJinJloopJmode
4 PowerJsupplyJbridges
5 IKUNET
9
Basic installation and configuration/Description of the user interface
2) ConnectJtheJinputJandJoutputJsignalJconnectionsJinJaccordanceJwithJtheJinstructionsJforJtheJmoduleJmanualsJandJtheJdiagramJshownJinJtheJpreviousJfigure.
3) DistributeJtheJheadendJpowerJsupplyJasJsymmetricallyJasJpossibleJ(seeJexampleJinJaboveJfigure).
Description of the user interfaceTheJinterfaceJpermitsJtheJuserJtoJcommunicateJeasilyJandJcomfortablyJwithJtheJheadend.JTheJlayoutJofJtheJmenusJandJsubmenusJofJtheJinterfaceJisJshownJinJtheJfollowingJdiagram:
TheJupperJpartJofJtheJinterfaceJdisplaysJmessagesJaboutJtheJcommunicationJstatusJwithJtheJheadend.JEachJmessageJisJcolour-coded:
JF Green:JnotifiesJthatJtheJinstructionJhasJbeenJcarriedJout.JF Red:JindicatesJthatJtheJinstructionJcouldJnotJbeJperformedJandJgivesJtheJreason.
KEY
1 ExitJbutton
2 InformationJbutton
3 PrintJbutton
4 MainJmenu
5 Submenus
6 Tabs
7 StatusJmessage
8 WorkJarea
EN
10
Basic installation and configuration/IKUNET bus configuration
IKUNET bus configurationTheJIKUNETJbusJisJanJEthernetJcommunicationJbusJbetweenJtheJheadendJmodules.JTheJIKUNETJbusJisJinstalledJusingJEthernetJpigtailsJsuppliedJwithJtheJmodules.JIfJnJisJtheJnumberJofJstationJmodules,Jn-1JEthernetJpigtailsJareJrequired.
Definition of the master module
NoTE
JJ RememberJtheJPCJconfigurationJpriorJtoJtheJconnectionJwithJtheJIKUNETJbus.
JJ TheJdefinitionJofJtheJmasterJmoduleJmustJbeJmadeJwithJanJSTF-100Jmodule.
NoTE
InJmixedJSTFJandJMTCJconfigurations,JanJSTFJmoduleJmayJneverJbeJanJMTCJmoduleJmaster.JInJtheseJcases,JtheJmasterJmoduleJmustJbeJanJMTCJmoduleJandJtheJSTFJmodulesJareJreservedJforJconfigurationJasJslaveJmodules.
1) StartJtheJconfigurationJofJtheJIKUNETJbusJforJtheJheadendJwithJtheJmodulesJdisconnectedJfromJeachJother.
2) ConnectJtheJselectedJmoduleJ(JAJ)JtoJtheJPCJ( B )JviaJitsJEthernetJconnectionJandJusingJanJRJ-45JcableJ(JCJ).
3) InJtheJPCJ(WindowsJXP)JgoJtoJStart > Con-trol panel > network ConneCtionS > loCal area ConneCtion > proper-tieS > internet protoCol (tCp/ip) > propertieS.
4) SelectJtheJUSe the following ip ad-dreSSJcheckbox.JEnterJtheJfollowingJIPJcon-figurationJparameters:
JF ip addreSS:J10.254.254.2JF SUbnet maSk:J255.255.255.0JF defaUlt gateway:J10.254.254.1
5) ClickJonJtheJaCCeptJbutton.
6) EnterJtheJIPJaddressJhttp://10.254.254.254JinJtheJwebJbrowser.JThisJtakesJyouJtoJtheJhomeJpageJofJtheJconnectedJmodule.
7) InJtheJhomeJpageJofJtheJselectedJmodule,J“Admin”JappearsJbyJdefaultJinJtheJUSerJfield.JEnterJtheJwordJ“admin”JinJtheJpaSSword fieldJandJclickJonJaCCept.
8) TheJmainJmanagementJwindowJforJtheJSTF-100JmoduleJasJslaveJmoduleJisJdisplayed.
STF-100 STF-100
11
Basic installation and configuration/IKUNET bus configuration
NoTE
TheJmoduleJwithJwhichJyouJhaveJcon-nectedJtheJPCJdisconnectsJautomaticallyJafterJ15JminutesJwithoutJinteraction.
9) InJtheJmainJmenu,JclickJonJmaSter mod-Ule > ConfigUration.JTheJgeneral SyStem parameterJConfigUration windowJisJdisplayed,JwithJtheJinStallation data tab.
10) EnterJtheJnameJofJtheJmoduleJinJtheJmodUle nameJfield.
NoTE
IKUSIJrecommendsJyouJgiveJaJdescriptionJtoJtheJmoduleJaccordingJtoJitsJpositionJinJtheJheadendJinJorderJtoJidentifyJtheJmodulesJlogicallyJandJphysically.JForJex-ample,JforJaJconfigurationJidenticalJtoJthatJproposedJinJtheJassemblyJsection,JincludeJtheJfollowingJidentificationsJ(onJtheJbase,JfromJrightJtoJleft:JStf-1 maSter and Stf-2).
11) ToJactivateJtheJmoduleJasJmasterJofJtheJheadend,JclickJonJtheJthiS Stf-100 iS the maSter modUleJcheckbox.JTheJmoduleJwillJbeJconfiguredJasJmasterJonceJtheJwindowJhasJbeenJsaved.
CAUTIoN
IfJtheJbackgroundJofJtheJfieldJisJred,JthisJmeansJthatJtheJdataJhasJbeenJmodi-fiedJbutJhasJnotJyetJbeenJsaved.JBeforeJchangingJtoJanotherJwindowJorJtab,JanyJmodifiedJdataJmustJbeJsavedJ(clickJonJSave).JOtherwise,JtheJmodifiedJdataJwillJbeJlostJandJtheJpreviousJinformationJstatusJwillJbeJmaintainedJinJtheJheadend.
NoTE
IfJtheJIKUNETJbusJisJconnectedJtoJanotherJEthernetJbus,JweJrecommendJyouJlimitJtheJIPJrangeJtoJtheJnumberJofJslaveJmodulesJinJtheJIKUNETJbus,JsoJthatJtheseJcanJbeJidentifiedJmoreJeasily.
12) ClickJonJexitJinJtheJmainJscreenJ(topJrightJcorner).
EN
12
Basic installation and configuration/IKUNET bus configuration
Name of slave modules
ContinueJwithoutJconnectingJtheJIKUNETJbus.JFollowJtheJstepsJbelowJforJeachJofJtheJremainingJmodulesJofJtheJheadendJ(slaveJmodules).
1) ConnectJtheJselectedJmoduleJ(JAJ)JtoJtheJPCJ( B )JviaJitsJEthernetJconnectionJandJusingJanJRJ-45JcableJ(JCJ).
2) EnterJtheJIPJaddressJhttp://10.254.254.254JinJtheJwebJbrowser.JThisJtakesJyouJtoJtheJhomeJpageJofJtheJconnectedJmodule.
3) InJtheJhomeJpageJofJtheJselectedJmodule,J“Admin”JappearsJbyJdefaultJinJtheJUSerJfield.JEnterJtheJwordJ“admin”JinJtheJpaSSwordJfieldJandJclickJonJaCCept.
4) EnterJtheJnameJofJtheJmoduleJinJtheJmodUle name (Stf-2, ngt-1, ngt-2, ngt-3, ngt-4)Jfield.
CAUTIoN
TheJcheckboxJthiS Stf-100 iS the maSter modUle mustJbeJleftJun-markedJforJtheJslaveJmodules.
5) ClickJonJSave.
6) ClickJonJexitJinJtheJmainJscreenJ(topJrightJcorner).
General configuration of the headend
WhenJtheJmasterJmoduleJforJtheJheadendJhasJbeenJdefined,JaccessJtoJtheJheadendJisJviaJtheJmasterJmodule.JToJaccessJtheJmasterJmoduleJitJisJnecessaryJtoJconfigureJtheJIPJaccessJofJtheJPCJandJenterJanotherJIPJaddressJinJtheJwebJbrowser.
1) ConnectJtheJIKUNETJbusJforJtheJheadendJwithJtheJEthernetJpigtailsJsuppliedJtogetherJwithJeachJmoduleJ(seeJexampleJinJtheJfigureJinJtheJGeneral descriptionJsection).
2) InJtheJPC,JmodifyJtheJIPJaddress,JfollowingJtheJsameJstepsJasJinJDefinition of the master module,JbutJincludingJtheJfollowingJparameters:
JF ip addreSS:JitJshouldJfollowJtheJrootJofJtheJIPJaddressJforJtheJmasterJmoduleJofJtheJheadend,JbutJbeJoutJofJitsJrange.JTheJaddressJrecommendedJbyJIKUSIJforJtheJdefaultJconfigurationJofJtheJmasterJmoduleJisJ192.168.1.2.
JF SUbnet maSk:J255.255.255.0JF defaUlt gateway:J192.168.1.1
3) ClickJonJtheJaCCeptJbutton.
4) InJtheJwebJbrowser,JenterJtheJIPJaddressJofJtheJmasterJmodule.JTheJdefaultJaddressJisJhttp://192.168.1.5.JThisJtakesJyouJtoJtheJhomeJpageJofJtheJheadendJmasterJmodule.
STF-100 STF-100
13
Basic installation and configuration/IKUNET bus configuration
5) InJtheJhomeJpageJofJtheJselectedJmodule,JenterJtheJwordJ“Admin”JinJtheJpaSSwordJfield.
6) ClickJonJaCCept.JTheJmainJscreenJofJtheJmas-terJmoduleJuserJinterfaceJisJaccessedJthroughJtheJgeneral headend parameter ConfigUration > inStallation dataJwindow.
Module registry and name
ProceedJasJfollowsJtoJregisterJtheJmodules:
1) GoJtoJtheJmenuJheadend > headend modUle liSt. TheJlistJofJmodulesJcon-nectedJtoJtheJIKUNETJbusJshouldJappearJonJtheJscreen.JEachJrowJcorrespondsJtoJaJmodule.JTheJrecognitionJstatusJinJIKUNETJandJtheJmoduleJregistryJinJtheJconfigurationJofJtheJheadendJcanJbeJdistinguishedJbyJtheJcolourJofJeachJrow:
JF Blue:JtheJmoduleJhasJbeenJrecognisedJinJtheJIKUNETJbusJbutJhasJnotJyetJbeenJregistered.
JF Red:JtheJmoduleJisJnotJrecognisedJinJtheJIKUNETJbusJandJhasJbeenJregisteredJprevi-ously.
JF LightJgreen:JtheJmoduleJisJrecognisedJinJtheJIKUNETJbusJandJhasJbeenJregistered.
2) ToJregisterJtheJidentifiedJmodules,JselectJtheJcheckboxJinJtheJregiSterJcolumnJforJallJtheJmodulesJwhichJformJpartJofJtheJheadendJandJclickJonJregiSter.JToJdeleteJtheJregistryJofJaJmoduleJwhichJisJpartJofJtheJheadend,JclickJonJ(JJJJJ).
3) NameJtheJmodulesJ(nameJcolumnJinJtheJlistJofJmodules).JProceedJasJfollows,JmoduleJbyJmodule:
a)J SearchJforJtheJmoduleJtoJbeJnamed.JFollowJaJlogicalJorderJwithJrespectJtoJtheJselectedJassemblyJorder.JExample:JfollowJtheJmodulesJfittedJfromJrightJtoJleft:J“STF-1”JandJ“STF-2”).
EN
14
Basic installation and configuration/Configuration of general parameters
NoTE
ToJidentifyJaJmodule,JinJtheJliSt of headend modUleS tableJclickJonJtheJcellJcorrespondingJtoJtheJMACJaddressJofJtheJmodule.JTheJcellJwillJchangeJtoJaJfluo-rescentJgreenJcolourJandJtheJSynCJandJStatUS controlJLEDsJforJtheJselectedJmoduleJflashJtogether.
b)J ClickJonJtheJmagnifyingJglassJiconJofJtheJmoduleJtoJbeJnamed.
c)J InJtheJmainJwindowJofJtheJuserJinterfaceJgoJtoJtheJmenuJJmaSter modUle > ConfigUration.
d)J EnterJtheJnameJofJtheJmoduleJinJtheJmodUle name field.
CAUTIoN
IfJtheJbackgroundJofJtheJfieldJisJred,JthisJmeansJthatJtheJdataJhasJbeenJmodifiedJbutJhasJnotJyetJbeenJsaved.JBeforeJchangingJtheJwindowJorJtab,JtheJmodifiedJdataJmustJbeJsavedJ(clickJonJSave).JOtherwiseJtheJmodifiedJdataJwillJbeJlostJandJtheJheadendJwillJremainJinJtheJsameJstatusJasJbefore.
STF-100 STF-100
15
Basic installation and configuration/Configuration of general parameters
Configuration of general parametersAllowsJtheJmodificationJofJtheJbasicJidentification,JnetworkJandJaccessJparametersJandJofJtheJheadendJfirmware.
ToJaccessJfromJtheJmainJmenu,JclickJonJmaSter modUle > ConfigUration.JJ identifiCation:
JF model: showsJtheJnameJofJtheJmoduleJmodel.
JF Serial nUmber: showsJtheJhardwareJidentificationJcode.
JF maC addreSS: showsJtheJnumberJwhichJidentifiesJtheJunitJforJnetworkJconnection.
JF modUle name: enterJtheJmoduleJname.JF loCation: allowsJtheJnameJofJtheJcityJinJ
whichJtheJunitJisJinstalledJtoJbeJentered.JF inStaller: allowsJtheJnameJofJtheJper-
sonJinstallingJtheJequipmentJtoJbeJentered.JF ContaCt nUmber. AllowsJtheJphoneJnumberJofJtheJinstallingJcompanyJtoJbeJ
entered.JF date of inStallation: allowsJtheJdateJonJwhichJtheJunitJisJinstalledJtoJbeJ
entered.JF maSter modUle: clickJonJtheJcheckboxJonJtheJrightJtoJselectJtheJmoduleJasJ
master. F Save:JclickJonJtheJbuttonJtoJsaveJtheJchanges.
JJ ikUnet network:JF maC addreSS. ShowsJtheJnumberJwhichJ
identifiesJtheJunitJforJnetworkJconnection.JF ip addreSS: showsJtheJnumberJofJtheJIPJ
address.JF network maSk: showsJtheJnetworkJ
maskJcode.JF defaUlt gateway: showsJtheJGatewayJ
IPJaddress.JF dhCp pool - Start: allowsJtheJnumberJofJtheJfirstJIPJaddressJinJtheJrangeJofJ
IPsJtoJbeJincludedJtoJbeJentered.JF dhCp pool - end : allowsJtheJnumberJofJtheJlastJIPJaddressJinJtheJrangeJofJIPsJ
toJbeJincludedJtoJbeJentered.JF modify ikUnet: clickJonJtheJbuttonJtoJsaveJtheJchanges.
JF reStore: clickJonJtheJbuttonJtoJomitJtheJchanges.
EN
16
Basic installation and configuration/Module configuration
JJ paSSword:JF old paSSword: enterJtheJcurrentJpass-
wordJforJtheJhomeJpage.JF new paSSword: enterJtheJnewJpass-
word.JF Confirm new paSSword: enterJtheJ
newJpasswordJagain.JF Send: clickJonJtheJbuttonJtoJsaveJtheJchanges.JF CanCel: clickJonJtheJbuttonJtoJomitJtheJchanges.
JJ reboot:JF reboot iCon ( ): rebootsJtheJmoduleJ
inJtheJeventJofJblocking.
JJ modUle firmware Update:JF modUle Updated verSion: showsJ
theJnumberJofJtheJcurrentJfirmwareJversion.JF verSion: listJofJimportedJfirmwareJversionJ
numbers.JF browSe: clickJonJtheJbuttonJtoJselectJtheJ
routeJforJtheJfirmwareJfileJtoJbeJimported.JF Update modUle: clickJonJtheJbuttonJtoJ
importJtheJselectedJfirmwareJfile.
Module configurationAllowsJtheJmodificationJofJtheJoperatingJparametersJforJtheJmultiswitch,JtheJinputsJandJtheJoutputJofJtheJmodule.JToJaccessJfromJtheJmainJmenu,JclickJonJheadend > liSt head-end modUleS.
NoTE
ToJstartJtheJheadendJconfiguration,JfirstJdefineJtheJmasterJmoduleJandJtheJidenti-ficationJofJtheJslaveJmodulesJforJtheJheadend,JasJdescribedJinJtheJsectionJBasic installation and configuration.
JJ liSt of headend modUleS:JF magnifying glaSS iCon ( ): clickJ
onJtheJiconJtoJaccessJtheJmoduleJconfigura-tion.
JF SUmmary: clickJonJtheJiconJ(JJJJJ)JtoJdisplay:JfreqUenCy, Symbol rate, ber, StatUS ofJtheJmoduleJinputsJandJtheJoUtpUt freqUenCy.
JF modUle name: showsJtheJnameJofJeachJmodule.JF family: showsJtheJfamilyJnameJofJeachJmodule.JF model: showsJtheJnameJofJtheJmoduleJmodel.
17
Basic installation and configuration/Module configuration
JF maC: clickJonJtheJbutton toJidentifyJallJtheJmodules.JF ip addreSS:JshowsJtheJIPJaddressJofJeachJmodule.JF StatUS: indicatesJtheJoperatingJstatusJofJtheJmodule.JIfJitJisJoperatingJcorrectly,J
theJiconJ(JJJJ)JisJdisplayed,JotherwiseJtheJiconJ(JJJJ)JisJdisplayed.JF alarm: thisJindicatesJwhetherJthereJisJanJoperatingJalarmJinJtheJmodule.JF regiSter: ToJregisterJtheJmodulesJidentified,JselectJtheJcheckboxJinJtheJreg-
iSterJcolumnJforJallJtheJmodulesJwhichJformJpartJofJtheJheadendJandJclickJonJregiSter.JToJdeleteJtheJregistryJofJaJmoduleJwhichJisJpartJofJtheJheadend,JclickJonJ(JJJJJ).
JF refreSh: clickJonJtheJbutton toJupdateJtheJinformationJonJtheJscreen.
Configuration of master STF module
Description of the multiswitch
ThisJallowsJtheJmodificationJofJtheJmultiswitchJoperatingJparametersJforJtheJmasterJSTFJmodule.JToJenterJfromJheadend > headend modUle liSt,JclickJonJtheJmagnifyingJglassJiconJofJtheJmasterJmodule.JGoJtoJSettingS > lnb/mUltiSwitCh.
JJ low loCal oSCillator freqUenCy (mhz): allowsJtoJenterJtheJlocalJoscillatorJfrequencyJvalueJforJtheJlowJbandJandJinformJtheJmasterJSTFJmoduleJofJtheJpresenceJandJcharacteristicsJofJtheJmultiswitch.
JJ high loCal oSCillator freqUenCy (mhz): allowsJtoJenterJtheJlocalJoscillatorJfrequencyJvalueJforJtheJhighJbandJandJinformJtheJmasterJSTFJmoduleJofJtheJpresenceJandJcharacteristicsJofJtheJmultiswitch.
JJ nUmber of inpUtS: clickJonJtheJdropdownJmenuJtoJselectJtheJnumberJofJinputsJforJtheJmasterJmodule:J
JF ForJaJconnectionJwithoutJmultiswitch,JselectJtheJ“0”JvalueJforJtheJmasterJmoduleJinputs.
JF ForJaJconnectionJwithJmultiswitch,JselectJtheJvalueJcorrespondingJtoJtheJnumberJofJmultiswitchJinputs.JNextJopenJtheJdropdownJmenuJlnb/mUltiSwitCh:
JÌ Satellite:JnameJofJtheJinputJsignalJtoJtheJmultiswitchJforJidentificationJinJsubsequentJconfigurations.JIKUSIJrecommendsJyouJidentifyJtheJtypeJofJsatel-lite,JpolarityJandJtheJbandwidthJofJtheJsignal.
JÌ mUltiSwitCh poSition: notifiesJofJtheJmultiswitchJinputJbeingJde-scribed.
JÌ polarity (v): clickJonJtheJdropdownJmenuJtoJselectJtheJpolarity:Jverti-Cal or horizontal.
JÌ band (khz):JforJeachJpolarityJselectJhigh onceJandJlowJonce.
JJ Save: clickJonJtheJbuttonJtoJsaveJtheJchanges.
EN
18
Basic installation and configuration/Module configuration
Configuration of inputs
ThisJallowsJtheJmodificationJofJtheJoperatingJparametersJforJtheJmasterJSTFJmoduleJinput.JToJenterJfromJheadend > headend modUle liSt,JclickJonJtheJmagnifyingJglassJiconJofJtheJmasterJmodule.JGoJtoJSettingS >JinpUt.
JJ inpUt:JF mUltiSwitCh oUtpUt: clickJonJtheJ
dropdownJmenuJtoJselectJoneJofJtheJfollow-ingJoptions:
JÌ ForJaJconnectionJwithJmultiswitchJse-lectJtheJinputJforJtheJmultiswitchJtoJbeJconnectedJtoJtheJSTF.
JÌ ForJaJconnectionJwithoutJmultiswitchJselectJmUltiSwitCh diSabled.
JF fi band: clickJonJtheJdropdownJmenuJtoJselectJtheJintermediateJsatelliteJbandJtype.
JF tranSponder freqUenCy (mhz): al-lowsJtheJfrequencyJvalueJtoJbeJselectedJforJtheJtransponderJtoJbeJreceived.
JF freqUenCy fi (mhz): allowsJtheJrequiredJintermediateJfrequencyJvalueJtoJbeJselected.J
JF inpUt rate (kbit/s): allowsJtheJmodificationJofJtheJinputJspeedJvalue.JF inpUt Signal: showsJifJthereJisJanJInputJsignal.JF ber: showsJtheJrateJofJbitsJthatJwereJincorrectlyJreceivedJbyJtheJInput.JF C/n (db): showsJtheJnoiseJlevelJinJtheJinputJ
signal.JF Signal power: showsJtheJpercentageJ
powerJofJtheJinputJsignalJwithJrespectJtoJtheJmaximumJpossible.
JF Save:JclickJonJtheJbuttonJtoJsaveJtheJchanges.
19
Basic installation and configuration/Module configuration
output configuration
ThisJallowsJtheJmodificationJofJtheJoperatingJparametersforJtheJmasterJSTFJmoduleJoutput.JToJenterJfromJheadend > headend modUle liSt,JclickJonJtheJmagnifyingJglassJiconJofJtheJmasterJmodule.JGoJtoJSettingS > oUtpUt.
JJ parameterS:JF freqUenCy (mhz):JallowsJtheJvalueJofJ
theJoutputJfrequencyJtoJbeJmodified.JF ofdmJmode:JclickJonJtheJdropdownJ
menuJtoJselectJtheJOFDMJtransmissionJparameter.
JF bandwidth (mhz):JclickJonJtheJdropJdownJmenuJtoJselectJtheJbandJwidthJvalueJforJtheJoutputJsignal.
JF gUard interval:JclickJonJtheJdropdownJmenuJtoJselectJtheJguardJintervalJforJtheJOFDMJsignal.
JF ConStellation:JclickJonJtheJdropdownJmenuJtoJselectJtheJdigitalJconstellationJlayout.
JF Code rate:JclickJonJtheJdropdownJmenuJtoJselectJtheJFECJcodingJconvolutionJcode.
JF attenUation (db):JclickJonJtheJdisplacementJbarJtoJmodifyJtheJoutputJlevelJofJtheJsignal.
NoTE
TheJadvancedJparametersJmayJonlyJbeJmodifiedJinJspecialJcases,JinJtheJmajorityJofJinstallationsJtheJfactoryJsettingsJshouldJnotJbeJchanged.
JJ advanCed parameterS.JClickJonJtheJright-handJcheckboxJtoJdisplayJtheJmenuJad-vanCed parameterS.
JF i-q format: clickJonJtheJdropdownJmenuJtoJselectJtheJformJ(normal orJinverted)JofJtheJI-QJoutputJchannelJspectrum.
NoTE
ToJmodifyJtheJvalueJofJtheJCofdm window rememberJthatJwhenJtheJband-widthJofJtheJCOFDMJoutputJisJreduced,JtheJinterferenceJfromJtheJadjacentJchan-nelJisJreduced,JbutJtheJefficiencyJofJtheJguardJintervalJisJreducedJproportionallyJandJmayJpreventJtheJtuningJofJtheJreceivers.
JF Cofdm window: clickJonJtheJhorizontalJdisplacementJbarJtoJmodifyJtheJbandJwidthJofJtheJCOFDMJchannelJoutput.
JF Cell id: clickJonJtheJhorizontalJdisplacementJbarJtoJmodifyJtheJnumberJofJcellsJtoJbeJallocatedJtoJtheJCOFDMJchannelJoutput.
EN
20
Basic installation and configuration/Module configuration
JF mpe feC dvb-h: clickJonJtheJdropdownJmenuJtoJactivateJorJdeactivateJtheJerrorJcorrectionJprotocol.JThisJpermitsJerrorsJinJtheJDVB-HJtransmissionJtoJbeJdetectedJandJcorrected.
JF timeSliCing dvb-h: clickJonJtheJdropdownJmenuJtoJactivateJorJdeactivateJtheJtimeslicing.JIfJtimeslicingJisJenabled,JtheJreceiverJswitchesJoffJduringJinactiveJperiodsJandJconsumptionJforJtransmissionJinJDVB-HJisJreduced.
JF dvb-h interlaCing: clickJonJtheJdropdownJmenuJtoJactivateJorJdeactivateJtheJbitJinterlacingJforJtheJcorrectionJofJtransmissionJcodeJerrorsJinJDVB-H.
JJ Save: clickJonJtheJbuttonJtoJsaveJtheJchanges.
JJ CanCel: clickJonJtheJbuttonJtoJcancelJtheJchanges.
JJ temperatUre (ºC): showsJtheJmoduleJtemperature.
JJ max. bitrate (mbps): showsJtheJmaximumJflowJofJtheJoutputJsignal.
JJ perCentage of empty CarrierS: showsJtheJpercentageJofJpackagesJreceivedJwithoutJinformation.
JJ theoretiCal minimUm C/n (db): showsJtheJtheoreticalJsignal/noiseJratioJre-quiredJatJtheJbaseJofJtheJsocketJsoJthatJtheJtelevisionJreceivesJtheJsignalJcorrectly.
Configuration of slave STF module
NoTE
TheJoperatingJparametersJforJtheJslaveJSTFJmoduleJinputsJandJoutputJfollowJtheJsameJconfigurationJmethodJasJtheJinputsJandJoutputJofJtheJmasterJSTFJmodule.
Input configuration
AllowsJtoJchangeJtheJoperationalJparametersJforJtheJslaveJSTFJmoduleJinput.JToJenterJfromJheadend > headend modUle liSt,JclickJonJtheJmagnifyingJglassJiconJofJtheJslaveJSTFJmodule.JGoJtoJSettingS >JinpUt.
ForJaJdescriptionJofJtheJoperatingJparametersJofJtheJslaveJSTFJmoduleJinputJinJthisJmanual,JpleaseJgoJtoJtheJsectionJ Configuration of the inputs.
output configuration
ThisJallowsJtheJmodificationJofJtheJoperatingJparametersJforJtheJslaveJSTFJmoduleJoutput.JToJenterJfromJheadend > headend modUle liSt,JclickJonJtheJmagnifyingJglassJiconJofJtheJslaveJSTFJmodule.JGoJtoJSettingS > oUtpUt.
ForJaJdescriptionJofJtheJoperatingJparametersJofJtheJslaveJSTFJmoduleJoutputJinJthisJmanual,JpleaseJgoJtoJtheJsectionJoutput configuration.
21
Basic installation and configuration/Service Management
Service Management
Selection of input services
1) ToJdefineJtheJservicesJtoJbeJemittedJthroughJtheJoutputJofJtheJDVB-TJoutputJsignal,JgoJtoJServ-iCeS > ServiCe management. InJtheJupperJsideJofJtheJheadend ServiCe managementJwindowJthereJisJaJtableJshowingJtheJservicesJavailableJinJtheJinput,JdifferentiatedJbyJmodules.
2) ClickJonJtheJiconJonJtheJleftJofJtheJrowJofJeachJmoduleJ(positionJJ1JJinJtheJaboveJfigure)JtoJgoJtoJtheJlistJofJinputJservices.
a)J ToJselectJaJparticularJservice,JactivateJtheJcheckboxJinJtheJaddJcolumnJ(JJ2JJ).
b)J WhenJallJtheJservicesJofJaJmoduleJhaveJbeenJenabledJforJtheJoutputJsignal,JclickJonJtheJSave ServiCeSJbutton.
KEY
1 SelectionJofJSTFJmodule.
2 SelectionJofJserviceJtoJtheJoutputJsignalJ(ifJtheJcheckboxJisJnotJdisplayed,JtheJserviceJhasJalreadyJbeenJselectedJatJtheJoutput).
3 ServiceJtype.JJLockJclosedJ=Jencrypted.JJLockJopenJ=Jfree.
4 Service:JnameJofJserviceJ(contextualJmenuJwhenJpassedJwithJtheJcursor:JinformationJonJServiceJID).
5 Input:JmoduleJinputJnumberJ(contextualJmenuJwhenJpassedJwithJtheJcursor:JinformationJonJOriginalJNetworkJIDJandJTransportJStreamJID).
6 OriginalJLCN:JLogicJControlJNumberJemittedJbyJtheJoperator.
EN
22
Basic installation and configuration/Service Management
Management of output services
NoTE
IfJtheJbandwidthJisJsaturated,JdeleteJtheJoutputJservicesJnotJrequiredJselectingJtheJcheckboxesJinJtheJdeleteJcolumnJ(JJ1JJ)JandJclickingJonJSave ServiCeS.
JJ LCNJmanagementJ(JJ4JJ):JJF TheJDVB-TJinputJservicesJhaveJanJLCNJ(LogicJControlJNumber)JwhichJisJtransmit-
tedJinJtheJoutputJservicesJ(seeJLCNJcolumn).JF TheJDVB-S/S2JinputJservicesJdoJnotJusuallyJhaveJanJLCN.JTheJheadendJautomati-
callyJallocatesJanJLCNJforJtheJDVB-TJoutputJsignalJofJtheseJservices.JF ToJmodifyJanJLCNJ(seeJLCNJcolumn,JcellsJwithJyellowJbackground):
i)J PlaceJtheJcursorJinJtheJLCNJcellJtoJbeJmodified.
ii)J ModifyJtheJLCN.
iii)J ClickJonJtheJSave lCn valUeSJbutton.
JJ OutputJservicesJsaturationJlevel:JTheJsaturationJlevelJofJtheJoutputJmultiplexesJcanJbeJcontrolledJwithJtheJinstructionJonJemptyJpacketsJ(stuffing)JandJtheJinformationJaboutJtheJdataJtransferJspeedJ(JJ5JJ).
JF TheJinformationJonJemptyJpacketsJreflectsJtheJavailableJbandwidthJinJtheJoutputJmultiplexJandJisJindicatedJinJrealJtimeJinJtheJlowerJtableJoUtpUt bitrate ofJtheJheadend ServiCe management windowJwithJtheJfollowingJcolumns:
JÌ max. bitrate: dataJtransferJspeedJofJtheJoutputJmultiplex.JÌ min. nUll:JminimumJpercentageJofJemptyJpacketsJperformed.
KEY
1 DeletionJofJtheJoutputJservice.
2 LockJopen:JserviceJprocessingJnotJencrypted.
3 LockJclosed:JserviceJencrypted.JJ“Ok”JiconJ=JunencryptionJcorrect.JJ
“NotJok”JiconJ=JunencryptionJfailed.
4 LCN:JLogicJControlJNumberJemittedJbyJtheJDVB-TJoutputJsignalJofJtheJheadend.JYellowJcellJ=JLCNJfree.
5 MonitoringJofJbandwidthJofJavailableJoutputJsignal.
23
Basic installation and configuration/Service Management
JÌ aCt. nUll:JpercentageJofJactualJemptyJpackets.JÌ max. nUll:JmaximumJpercentageJofJemptyJpacketsJperformed.
JF TheJbitrateJcolumnJinJtheJaboveJtablesJinpUt ServiCeSJandJoUtpUt ServiCeS providesJinformationJonJtheJindividualJdataJtransferJspeedJforJeachJservice.
EN
Advanced functionsThisJsectionJdescribesJtheJadditionalJfunctionsJofJtheJuserJinterface.
NoTE
TheJwordJ“Live”JappearsJinJaJredJrectangleJinJtheJupperJrightJcornerJofJtheJmainJscreen.JThisJmeansJthatJtheJheadendJisJcheckingJevaluationJdata.
NoTE
InJlocalJconfigurationJthereJareJcontentsJwhichJareJalsoJdisplayedJinJheadend > headend modUle liSt > detailS
Save/Restore FunctionThisJallowsJtheJcurrentJconfigurationJofJtheJselectedJmodelJtoJbeJstoredJinJaJtextJfileJ(.txt)JandJthenJimportedJlater.JToJaccessJfromJtheJmainJmenu,JclickJonJheadend > headend modUle liSt > aCCeSS modUle > general > Save/reStore.
JJ SaveJfunction:JselectJtheJtabJforJtheJmoduleJforJwhichJyouJwishJtoJsaveJtheJconfigura-tion,JselectJSave the ConfigUration and clickJonJreboot.
JJ RestoreJFunction:JselectJtheJtabJforJtheJmoduleJfromJwhichJyouJwishJtoJimportJtheJconfiguration,JselectJreStore the ConfigUrationJandJclickJonJreboot.JThisJfunctionJcanJbeJusedJtoJstreamlineJtheJconfigurationJprocessJforJfutureJstations.
Internet AccessTheJInternetJaccessJnotJonlyJallowsJtheJheadendJtoJaccessJtheJInternetJ(forJexampleJtoJdisplayJitsJloca-tion),JbutJitJallowsJanJoperatorJtoJaccessJandJcon-figureJtheJheadendJfromJtheJexterior.JToJaccessJfromJtheJmainJmenu,JclickJonJheadend > aCCeSS via internet.
JJ ConfigUre aCCeSS via internet: selectJtheJcheckboxJtoJactivateJthisJfunctionJandJthenJconfigureJtheJheadendJaccessJtoJInternetJ(IPJaddress,JnetworkJmask,JandJdefaultJgateway).
JJ maC addreSS: headendJidentifierJforJtheJnetworkJconnection.
J USe dhCp to aSSign ip addreSS:JactivateJtheJcheckboxJsoJthatJtheJDHCPJserverJautomaticallyJassignsJanJIPJaddress:JDeactivateJtheJcheckboxJtoJenterJtheJIPJaddress,JnetworkJmaskJandJdefaultJgatewayJmanually.
J ip addreSS:JenterJtheJIPJaddressJifJtheJDHCPJisJnotJenabled.
J network maSk:JenterJtheJnetworkJmaskJifJtheJDHCPJisJnotJenabled.
25
Advanced functions/Network functions
J defaUlt gateway:JenterJtheJdefaultJgatewayJifJtheJDHCPJisJnotJenabled.
J primary dnS Server:JtoJuseJaJDNSJserver,JenterJtheJIPJaddressJofJtheJprimaryJDNSJserverJprovidedJbyJtheJdomainJsupplier.
J SeCondary dnS Server:JtoJuseJaJsecondaryJDNSJserver,JenterJtheJIPJaddressJofJtheJsecondaryJDNSJserverJprovidedJbyJtheJdomainJsupplier.
J modify with: network:JclickJonJtheJbuttonJtoJsaveJtheJchanges.
J reStore:JclickJonJtheJbuttonJtoJomitJtheJchanges.
Network functionsThisJenablesJtheJparametersJrelatingJtoJtheJdistributionJnetworkJtoJbeJconsultedJandJconfig-ured.JToJaccessJfromJtheJmainJmenu,JclickJonJheadend > headend network.
JJ InJtheJnetwork ConfigUrationJtabJtheJnameJandJnetworkJidentifierJcanJbeJconsultedJandJedited.
JF edit/Save:JclickJonJtheJiconJ(JJJJJ)JtoJmodifyJtheJnetworkJnameJandJtheJNID.JNext,JtheJSaveJiconJisJdisplayedJ(JJJJJ).JClickJonJSaveJtoJstoreJtheJnetworkJnameJandJtheJNID.
JF network name: nameJofJtheJdistributionJnetwork.JF nid: networkJidentifier,JrequiredJtoJtuneJtheJsupplierJserviceJchannels.JF no. CUrrent/regiStered modelS: quantityJofJheadendJmodulesJandJ
quantityJofJregisteredJmodules.JJJJJ
JJ TheJmodUleS in network tabJcontainsJallJtheJinformationJregardingJtheJnetwork:
JF name: moduleJname.
JF inpUt freq. (hz): showsJtheJinputJfrequency.
JF oUtpUt freq. (hz): showsJtheJoutputJfrequency.
JF family: nameJofJmoduleJfamily.
JF model: nameJofJmoduleJmodel.
EN
26
Advanced functions/Advanced global transport processing
Advanced global transport processingEnablesJtheJconfigurationJofJallJtheJadditionalJfunc-tionsJofJtheJmodules,JtheJnetworkJandJtheJservices.JToJaccessJfromJtheJmainJmenu,JclickJonJServiCeS > advanCed tS proCeSSing.
JJ InJtheJmain network tabJtheJadvancedJoperatingJofJtheJnetworkJcanJbeJedited,JandJservicesJnotJincludedJinJtheJinputJcanJbeJse-lectedJorJblocked.
JF nit regeneration SettingS:JJÌ aUto ServiCeS liSt:JselectJtheJcheckboxJtoJincludeJaJservice_list_des-
criptorJinJtheJNIT,JgeneratedJbyJtheJmasterJmoduleJandJbasedJonJtheJservicesJavailableJinJtheJheadendJoutput.
JÌ nit model:JclickJonJtheJdropdownJmenuJtoJselectJoneJofJtheJthreeJavailableJNITJmodels:
JJ withoUt nitJMODEL:JtheJmasterJmoduleJgeneratesJanJNITJfromJscratch,JfromJtheJselectedJoutputJfrequencies,JtheJoutputJservicesJandJtheJselectedJLCN.
JJ nit integration:JcalculatesJaJnewJNITJfromJtheJNITJinJtheJinputJsignals,JifJthereJisJrelevantJinformationJinJtheJinputJNITJthisJisJsentJtoJtheJoutput.
JJ inpUt nitS: calculatesJaJnewJNITJfromJtheJNITsJselectedJasJmodelJforJtheJDVB-S/S2JinputJsignals.
JJ file nitS: theJNITJareJgeneratedJbasedJonJuser-loadedJinformationJfromJanJexternalJfile.
NoTE
TheJheadendJautomaticallyJallocatesJanJavailableJLCNJvalueJforJtheJsatelliteJservices.
Ì offSet lCn:JpermitsJtheJadditionJofJanJoffsetJLCN.
JÌ lCn mode:JclickJonJtheJdropdownJmenuJtoJselectJtheJLCNJtransmissionJstandardJinJtheJNIT:Joff (noJLCNJentered), eUropean Standard (de-fault), nordig v1 2 Standard, nordig v2 3 Standard, generiC mode (forJexampleJforJAustralia).
JÌ download tableS:JclickJonJtheJwordJnit-Sdt toJdownloadJtheJtablesJtoJtheJPC.
JF add ServiCeS not preSent in the inpUtS:
Ì modUle - inpUt:JclickJonJtheJdropdownJmenuJtoJselectJtheJmoduleJandJtheJinputJfromJwhichJyouJwishJtoJselectJservicesJnotJincluded.
Ì Sid:JpermitsJtheJadditionJofJaJnotJincludedJserviceJidentificationJnumberJwhichJyouJwishJtoJselect.
Ì add:JclickJonJtheJiconJ(JJJJJ)JtoJsaveJtheJchanges.
27
Advanced functions/Reports
F advanCed modUle ConfigUration:JclickJonJSee modUleS toJopenJtheJdropdownJmenu.JThisJfunctionJpermitsJtheJmanagementJofJtheJnon-referencedJPIDJforJeachJmoduleJwhichJareJnotJlistedJinJanyJtable,JandJmayJbeJunblocked.J
NoTE
InJanJSTFJmodule,JbyJdefaultJnoJoutputJserviceJisJselectedJandJtheJrequiredJoutputJservicesJmustJbeJselectedJoneJbyJone.JInJanJSTFJmodule,JallJtheJoutputJservicesJareJselectedJbyJdefaultJandJyouJhaveJtoJselectJtheJoutputJservicesJyouJwishJtoJdeleteJoneJbyJone.J
JJ FromJtheJexternal nit tabJaJfileJofJNITJtablesJcanJbeJimported.JClickJonJSeleCt file to be loadedJtoJactivateJtheJimportJfunction.
a)J ClickJonJbrowSe andJselectJtheJpathJwhereJtheJNITJtableJfileJisJlocated.
b)J ClickJonJSend toJimportJtheJfileJorJclickJonJCanCel toJdeactivateJtheJimportJfunction.
ReportsTheseJcontainJallJtheJupdatedJinformationJaboutJtheJoperatingJofJtheJheadend.JThereJareJ5JdifferentJreportsJaccordingJtoJtheJcontent:JStatUS information, general re-port, general headend report, ServiCeS report, headend logS
Status information
LocatedJinJtheJmenuJmaSter modUle > StatUS information. ContainsJallJtheJinformationJregardingJtheJstatusJofJtheJJmoduleJcommunication:
JJ general:JF inpUt: inputJcommunicationJstatus.
JF oUtpUt: communicationJstatusJofJoutput.
JF general: generalJoperatingJstatusJofJheadend.
JJ detailS: thisJisJanJinformationJfileJforJtheJheadendJstatusJwhichJincludesJtheJfollow-ingJstates:Jgeneral, inpUt, diSeqC, tS proCeSSing, oUtpUt.
NoTE
ToJdownloadJinformationJfromJthisJtab,JclickJonJtheJSave to pC buttonJinJtheJlowerJpartJofJtheJscreen.
EN
28
Advanced functions/Reports
General report
JJ LocatedJinJtheJmenuJConfigUration > general report. ContainsJallJtheJinforma-tionJregardingJtheJgeneralJparametersJofJtheJheadend:
JJ inStallation data:JgeneralJidentificationJparametersJforJtheJheadend.
JJ network:JnetworkJparameterJinformation.
JJ SettingS: operationalJparametersJforJinput,Joutput,JLNBJ/JMultiswitch,JLNB.
General headend report
LocatedJinJtheJmenuJreportS > general headend report.JContainsJinformationJregard-ing:
JJ inStallation data:JgeneralJidentificationJparametersJforJtheJheadend.
JJ SyStem time and CoUntry:JtimeJcon-figurationJparametersJforJtheJheadend.
JJ headend oUtpUt:JnetworkJoperatingJparameters.
Service report
LocatedJinJtheJmenuJreportS > ServiCe report.JContainsJallJtheJinformationJaboutJtheJservices:
JJ inpUt ServiCeS:JclickJonJtheJiconJ(JJJJJ)JforJmoreJdetailedJinformation.
JJ oUtpUt ServiCeS:JclickJonJtheJiconJ(JJJJJ)JforJmoreJdetailedJinformation.
JJ oUtpUt bitrate:clickJonJtheJiconJ(JJJJJ)JforJmoreJdetailedJinformation.
Headend logs
LocatedJinJtheJmenuJreportS > headend logS. ContainsJallJtheJinformationJaboutJtheJsys-temJlogs.
JJ Show inpUtS: clickJonJtheJdropdownJmenuJtoJselectJtheJfilterJbyJlevelJoption.
29
Advanced functions/Reports
JJ Show inpUtS: clickJonJtheJsecondJdropdownJmenuJtoJselectJtheJfilterJbyJprocessJstatusJoption.
JJ apply filterS: clickJonJtheJbuttonJtoJstartJtheJfilterJprocess.
EN
Advanced functions/Reports
Unit recyclingRECYCLING of ELECTRICAL AND ELECTRoNIC EqUIPmENT
(Applicable in the European Union and in European countries with selective waste collection systems.)
ThisJsymbolJonJyourJunitJorJitsJpackagingJindicatesJthatJthisJproductJcannotJbeJtreatedJasJgeneralJdomesticJwasteJandJmustJbeJhandedJinJatJtheJcorrespondingJpointJofJcollectionJforJelectricJandJelectronicJequipment.JByJensuringJthisJproductJisJdisposedJofJcorrectlyJyouJwillJhelpJpreventJnegativeJconsequencesJforJtheJenvironmentJandJhumanJhealth,JwhichJcouldJotherwiseJbeJcausedJbyJinappropri-ateJwasteJhandlingJofJthisJproduct.JRecyclingJofJmaterialsJhelpsJpreserveJnaturalJresources.JForJmoreJdetailedJinformationJonJtheJrecyclingJofJthisJproduct,JpleaseJcontactJyourJlocalJcouncil,JyourJnearestJcollectionJpointJorJtheJdistributorJfromJwhomJyouJpurchasedJtheJproduct.
CE Certificate/STF-201
3131
CE CertificateByJreproducingJtheJCEJmarking,JIKUSIJguaranteesJunitJcomplianceJwithJtheJcorrespondingJharmonisedJstandards.
STF-201
EC-Declaration of Conformity
We, Manufacturer
IKUSI, Angel Iglesias, S.A.
Paseo Miramón, 170
E-20009 San Sebastián, Spain
declare that the product
marking
E M C
San Sebastián, May 2010
Luis Rodríguez NavarreteR&D Director
is in conformity with
Council Directive 89/336/EEC (EMC Directive)Standards to which conformity is declared:
STC-100 ,, STC-200 ,, STF-100
DVB-S/S2 to DVB-T Transmodulators
EN 50083-2 :2007
Cabled distribution systems for television and sound signals.
Part 2: Electromagnetic compatibility for equipment.
EN
Ángel Iglesias, S.A.Paseo Miramón, 17020009 San Sebastián, SpainTel. +34 943 44 88 00Fax +34 943 44 88 [email protected]
120,126a