MALDI Mass Spectrometer
MALDI-7090
MO363
2
A New Dimensionin MALDI TOF-TOF Design.. .
. . .the MALDI-7090™
Unparalleled MS/MS resolution
High mass accuracy
True 2 kHz acquisition speed in MS and MS/MS mode
Ultra fast solid-state UV laser
Low- and high-energy fragmentation
Integrated 10 plate loader
Wide-bore ion optics
In-built security and auditing
Multi-user software environment
Unique UV laser source cleaning
3
The MultiPlex™ platform has been designedas a multi-user walk-up system offeringunparalleled versati l ity and efficiency
TrueClean™• Fully automated UV laser-based source cleaning
• Novel patented Shimadzu technology
• Software-driven scanning reflective source optics to directthe laser during source cleaning
• Highly efficient, rapid cleaning without the need for sourceremoval or venting
• Planned source cleaning can be scheduled in a fullyautomated way
MultiPlex maximizes the efficient use of the MALDI-7090
through the combination of the integrated 10 plate loader, the
2 kHz ultra fast UV laser and the MALDI Solutions™ multi-user
environment software.
MultiPlex enables both manual investigation and fully
automated high-throughput analyses accommodating all types
of experiments from single spot investigation to even the
longest multi-plate LC-MALDI separations. Furthermore, it is
also compatible with the FlexiMass-SR™ steel reusable and
FlexiMass-DS™ disposable polymeric microscope slide format
MALDI targets.
The MALDI-7090 is an ideal platform for individual laboratories
and core facilities alike.
MultiPlex expertly manages the MALDI-7090 workflow.
Experimental set-up, data processing and results review is now
possible from any workstation linked to the instrument network
thus creating a highly efficient and versatile multi-user interface.
The realtime experiment queue within MultiPlex streamlines
automated analyses such as LC-MALDI by assigning specific
plate locations within the loader and monitoring progress of the
submitted experiments. Plates can be loaded and unloaded from
the 10 plate loader ready for analysis even while the instrument
is running another experiment. The loader chamber also has the
option of being held at standard atmosphere or vented to
nitrogen to protect more sensitive samples.
Designed for maximum reliability, MultiPlex offers the ultimate
flexibility in both high-throughput and multi-user environments.
Wide-bore Optics• Optimized focussing of the ion
beam using increased diameterextraction optics
• Minimized risk of sourcecontamination over time
• Reduced need for source cleaningand maintenance
Proprietary ultrafast laser
• 2 kHz ultra fast solid-state UVlaser in MS and MS/MS mode
• 355 nm wavelength compatiblewith a variety of matrixcompounds and samples
• Variable beam focus from 10 µmto >100 µm
• Reliable with long lifetime
• Innovative Shimadzu technology
HD Sample Viewing • State-of-the-art high-definition
viewing optics, with crystal clearimage
• High quality image of the MALDIsample spot
• 10 µm resolution sample viewing
• Full HD colour picture (1080p)with long-life LED illumination
• Software-controlled variablefocus, adapted to viewingdifferent surfaces
Before
After
Example of a small area cleaned using TrueClean
A source design l ike no other
MALDI-7090A New Dimension in MALDI TOF-TOF Design
4
Hyper-MS2™ – a new stancombining core technologies pat
%In
ten
sity
100
90
80
70
60
50
40
30
20
10
01190 1200 1210 1220 1230 1240 1250 1260 1270 1280 1290 1300
m/z
wa12
y12-2
y12
wa13
PPPPPPPPPPPPPPR
ASDF™ – unparalleledMALDI TOF-TOFion resolution
ASDF – Axial Spatial Distribution Focussing is a patented
Shimadzu technology that enables unparalleled resolution
in MS/MS mode. Through correction of the axial spatial
distribution of the ions generated, mass resolution is
significantly increased and becomes essentially
independent of the laser power and sample topography.
With ASDF, the MALDI-7090 can achieve mass resolution
in MS/MS of 10 000 FWHM – unobtainable through
pulsed extraction alone. MS/MS fragmentation in the MALDI-7090 is true high-energy
CID (HE-CID).
The ions enter the CID cell with full 20 keV extraction energy.
Furthermore, collisions with helium rather than heavier gases
(air or argon) result in the most efficient generation of ions
only associated with HE-CID (e.g. side chain fragmentation).
MS/MS fragmentation is further enriched by retaining all of
the metastable decay ions through the reflectron analyzer,
maximizing the amount of information extracted from each
sample.
All of these features provide the MALDI-7090 with the
highest possible efficiency for metastable and high-energy
CID generation and detection.
High- and low-energyfragmentation
5MALDI-7090
A New Dimension in MALDI TOF-TOF Design
dard in MS/MS acquisition,ented and exclusive to Shimadzu
0
10
20
30
40
50
60
70
80
90
100
m/z860 870 880 890 900 910 920 930 940 950 960 970 980
0
10
20
30
40
50
60
70
80
90
100
m/z860 870 880 890 900 910 920 930 940 950 960 970 980
0
10
20
30
40
50
60
70
80
90
100
m/z1030 1032 1034 1036 1038 1040 1042 1044 1046 1048 1050 1052 1054 1056 1058 1060 1062 1064 1066 1068 1070
MS/MSlow resolution ion gatepeptide A + peptide B
MS/MS high resolution ion gate
peptide A only
y7 peptide A
(b-H2O)7 peptide A
b7 peptide A
y7 peptide A
(b-H2O)7 peptide A
b7 peptide A
y7 peptide B
(b-H2O)7 peptide B
b7 peptide B
peptide A
peptide B
The MALDI-7090 is equipped with a dual wire
Bradbury-Nielsen high resolution precursor
ion gate.
Compounds of similar nominal mass may
produce fragment ion spectra that contain
ions from both precursors. However the high
resolution ion gate allows the individual
gating of species close in nominal mass thus
producing distinct fragment ion spectra.
High resolution ion gate
6
MALDI-7090 ultimate performance
NTPpSQHDHpSIQHSPER
(M+H)+Neutral loss
of H3PO4 (98 Da)Neutral loss
of H3PO4 (98 Da)
1780 1800 1820 1840 1860 1880 1900 1920 1940 1960 1980 2000 2020
m/z
%In
ten
sity
100
90
80
70
60
50
40
30
20
10
0
1808.156
1807.126
1905.063
1790.125
1789.106
1805.0081843.089 1863.127 1887.964 1923.089
1954.304
1993.979
1985.792
551.55
573.54
645.48
829.73
x20
100
80
60
40
20
0680 700 720 740 760 775
O
O
OOO
O
%In
ten
sity
100
90
80
70
60
50
40
30
20
10
0500 540 580 620 660 700 740 780 820 860
m/z
High-energy CIDfragment ions
Hyper-MS2 – post-translational modification analysis
High-energy CID – lipid analysis
7MALDI-7090
A New Dimension in MALDI TOF-TOF Design
Coupling the MALDI-7090 with MALDI Solutions provides a stable,high-throughpu t multi-user environment which is ideally placed tomeet the demands of today’s modern high-tech laboratory
MALDI Solutions™ – a software suite delivering more forthe multi-user environment
• Define, acquire and view experiments from the MALDI-7090
• Create experiments and review results using MALDI Solutions on anycomputer on the user network
• Collaborate and share results in completely new ways
• Full data export to industry standards – imzML, mzML
• Manual acquisition mode for full control of the instrument or fullautomation using the integrated 10 plate loader
• Administrator-definable user-specific roles from simpleacquisition to full control with method development,acquisition and processing
• Centralized secure database for data storage(Microsoft® SQL server)
• User-specific access / restriction to experiments and results
• High level of security, essential in multi-user environments
• Full audit trail
• Provides the level of control required in regulatoryenvironments
• Allows 21 CFR part 11 compliance
Company names, product/service names and logos used in this publication are trademarks and trade names of Shimadzu Corporation and its affiliates. In this publication, those namesand logos may be used without trademark symbol “TM” or “®”.Third-party trademarks and trade names may be used in this publication to refer to either the entities claiming the marks and names or their products. Shimadzu Corporation disclaimsany proprietary interest in trademarks and trade names other than its own.
For Research Use Only. Not for use in diagnostic procedures. The contents of this publication are subject to change without notice. Shimadzu does not assume any responsibility or liabilityfor any damage, whether direct or indirect, relating to, or arising out of the use of this publication.
MA
LDI-7090
t
MO363 v2 May 2013
Founded in 1875, Shimadzu Corporation, a leader in thedevelopment of advanced technologies, has adistinguished history of innovation built on thefoundation of contributing to society through scienceand technology. We maintain a global network of sales,service, technical support and applications centres on sixcontinents, and have established long-term relationshipswith a host of highly trained distributors located in over100 countries. For information about Shimadzu, and tocontact your local office, please visit our web site atwww.shimadzu.com
Kratos Analytical Ltd.Wharfside, Trafford Wharf Road, Manchester M17 1GP, UKPhone: +44 161 888 4400 Fax. +44 161 888 4402URL http://www.shimadzu.com/an/