macleay street...2017/06/20  · 30/01/2017 1 of 5 6xlwh :looldp 6wuhhw 32 %r[ 3ruw 0dftxdulh 16:...

5
SW SW SW SW SW SW SW 40.462 40.375 16.0 16.0 19.446 19.447 20.698 20.814 MACLEAY STREET NORTH STREET EXISTING RESIDENCE 2 1 RELOCATED HOME Hopkins Consultants Pty Ltd C Liability limited by a scheme approved under &TCYKPI 0WODGT4GHGTGPEG &TCHVKPI 5ECNG 5JGGV 5K\G 7082-06 Professional Standards Legislation 4GXKUKQP &CVG 5JGGV 0WODGT PROPOSED SUBDIVISION OF LOT 4 T6-16-252 MACLEAY STREET, FREDERICKTON GA 1:500 DEVELOPMENT APPLICATION FOR SUBDIVISION AND MULTI-DWELLING HOUSING NORTH STREET, FREDERICKTON A3 A 30/01/2017 1 of 5 6XLWH :LOOLDP 6WUHHW ā 32 %R[ 3RUW 0DFTXDULH 16: ā $%1 7HOHSKRQH ā )DFVLPLOH ā (PDLO PDLO#KRSFRQFRPDX HOPKINS SUBJECT TO COUNCIL APPROVAL, FINAL DESIGN, CONSTRUCTION, FINAL SURVEY AND REGISTRATION AT LAND AND PROPERTY INFORMATION NSW. ALL AREAS AND DIMENSIONS ARE SUBJECT TO FINAL SURVEY. EASEMENTS ARE SUBJECT TO COMPLETION OF ENGINEERING CONSTRUCTION AND APPROVAL BY COUNCIL. 5 2.5 0 10 15 Full Size 1:500 ; SCALE (m) APPENDIX C ITEM 13.1 Page 11 20JUN2017

Upload: others

Post on 13-Jul-2020

1 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: MACLEAY STREET...2017/06/20  · 30/01/2017 1 of 5 6XLWH :LOOLDP 6WUHHW 32 %R[ 3RUW 0DFTXDULH 16: $%1 7HOHSKRQH )DFVLPLOH (PDLO PDLO#KRSFRQ FRP DX HOPKINS SUBJECT TO COUNCIL APPROVAL,

SW SW

SW

SW

SW

SW

SW

40.462

40.375

16

.0

16

.0

19

.4

46

19

.4

47

20.698

20.814

MACLEAY STREET

NO

RT

H S

TR

EE

T

EXISTING

RESIDENCE

2

1

646.6m²

403.6m²

RELOCATED

HOME

Hopkins Consultants Pty Ltd

C

Liability limited by a scheme approved under

7082-06

Professional Standards Legislation

PROPOSED SUBDIVISION OF

LOT 4 T6-16-252

MACLEAY STREET, FREDERICKTON

GA

1:500

DEVELOPMENT APPLICATION FOR SUBDIVISIONAND MULTI-DWELLING HOUSINGNORTH STREET, FREDERICKTON

A3

A

30/01/2017

1 of 5

Suite 1 / 109 William Street · PO Box 1556 Port Macquarie NSW 2444 · ABN 27 055 060 878

Telephone: 02 6583 6722 · Facsimile: 02 6584 9009 · Email: [email protected]

HOPKINS

SUBJECT TO COUNCIL APPROVAL, FINALDESIGN, CONSTRUCTION, FINAL SURVEYAND REGISTRATION AT LAND ANDPROPERTY INFORMATION NSW.

ALL AREAS AND DIMENSIONS ARE SUBJECTTO FINAL SURVEY.

EASEMENTS ARE SUBJECT TO COMPLETIONOF ENGINEERING CONSTRUCTION ANDAPPROVAL BY COUNCIL.

52.50 10 15

Full Size 1:500 ; SCALE (m)

APPENDIX CITEM 13.1

Page 1120JUN2017

Page 2: MACLEAY STREET...2017/06/20  · 30/01/2017 1 of 5 6XLWH :LOOLDP 6WUHHW 32 %R[ 3RUW 0DFTXDULH 16: $%1 7HOHSKRQH )DFVLPLOH (PDLO PDLO#KRSFRQ FRP DX HOPKINS SUBJECT TO COUNCIL APPROVAL,

SW SW SW SW SW SW

SW SW SW SW SW SW SW SW SW SW SW SW SW SW SW SW SW SW SW

SW SW SW SW

SW

10

.4

4

6.2

1.1

65

5.5

4.5

1.0

1.0

00

4.5

6

1.0

1.2

25

6.0

NO

RT

H S

TR

EE

T

EXISTING RESIDENCE

RELOCATED HOUSE

STEEL FRAME

C'BOND ROOF

CARPORT

3.5x6m

STEEL FRAME

ZINC CLAD

SINGLE GARAGE &

AWNING 6.5x6.5m

Hopkins Consultants Pty Ltd

C

Liability limited by a scheme approved under

7082-06

Professional Standards Legislation

PROPOSED RELOCATED HOME

SITE LOCATION PLAN

MACLEAY STREET, FREDERICKTON

GA

1:400

DEVELOPMENT APPLICATION FOR SUBDIVISIONAND MULTI-DWELLING HOUSING

MACLEAY STREET, FREDERICKTON

A3

A

30/01/2017

2 of 5

Suite 1 / 109 William Street · PO Box 1556 Port Macquarie NSW 2444 · ABN 27 055 060 878

Telephone: 02 6583 6722 · Facsimile: 02 6584 9009 · Email: [email protected]

HOPKINS10.50 32

Full Size 1:100 ; SCALE (m)

APPENDIX CITEM 13.1

Page 1220JUN2017

Page 3: MACLEAY STREET...2017/06/20  · 30/01/2017 1 of 5 6XLWH :LOOLDP 6WUHHW 32 %R[ 3RUW 0DFTXDULH 16: $%1 7HOHSKRQH )DFVLPLOH (PDLO PDLO#KRSFRQ FRP DX HOPKINS SUBJECT TO COUNCIL APPROVAL,

Hopkins Consultants Pty Ltd

C

Liability limited by a scheme approved under

7082-06

Professional Standards Legislation

PROPOSED RELOCATED HOME

ELEVATION AND FLOOR PLAN

MACLEAY STREET, FREDERICKTON

GA

1:400

DEVELOPMENT APPLICATION FOR SUBDIVISIONAND MULTI-DWELLING HOUSING

MACLEAY STREET, FREDERICKTON

A3

B

30/01/2017

3 of 5

Suite 1 / 109 William Street · PO Box 1556 Port Macquarie NSW 2444 · ABN 27 055 060 878

Telephone: 02 6583 6722 · Facsimile: 02 6584 9009 · Email: [email protected]

HOPKINS

WESTERN ELEVATION

SCALE 1:100

FLOOR PLAN

SCALE 1:100

10.50 32

Full Size 1:100 ; SCALE (m)

EASTERN ELEVATION

SCALE 1:100

SOUTHERN ELEVATION

SCALE 1:100

NORTHERN ELEVATION

SCALE 1:100

STUMPS @ 1800 CTRS

TO ENGINEERS

SPECIFICATIONS

STUMPS @ 1800 CTRS

TO ENGINEERS

SPECIFICATIONS

STUMPS @ 1800 CTRS

TO ENGINEERS

SPECIFICATIONS

STUMPS @ 1800 CTRS

TO ENGINEERS

SPECIFICATIONS

NOTE: SITE CLASS M

FOOTINGS - BORED CONCRETE

PIERS 450DIA SOCKED INTO FIRM

CLAY - MINIMUM 600 DEEP @ 1800

CTRS

INSPECTION/CERTIFICATION BY

MICHAEL MOWLE CPEng MIEAust

APPENDIX CITEM 13.1

Page 1320JUN2017

Page 4: MACLEAY STREET...2017/06/20  · 30/01/2017 1 of 5 6XLWH :LOOLDP 6WUHHW 32 %R[ 3RUW 0DFTXDULH 16: $%1 7HOHSKRQH )DFVLPLOH (PDLO PDLO#KRSFRQ FRP DX HOPKINS SUBJECT TO COUNCIL APPROVAL,

Hopkins Consultants Pty Ltd

C

Liability limited by a scheme approved under

7082-06

Professional Standards Legislation

PROPOSED SINGLE GARAGE & AWNING

ELEVATION AND FLOOR PLAN

MACLEAY STREET, FREDERICKTON

GA

1:400

DEVELOPMENT APPLICATION FOR SUBDIVISIONAND MULTI-DWELLING HOUSING

MACLEAY STREET, FREDERICKTON

A3

A

03/05/2017

4 of 5

Suite 1 / 109 William Street · PO Box 1556 Port Macquarie NSW 2444 · ABN 27 055 060 878

Telephone: 02 6583 6722 · Facsimile: 02 6584 9009 · Email: [email protected]

HOPKINS

WESTERN ELEVATION

SCALE 1:100

FLOOR PLAN

SCALE 1:100

10.50 32

Full Size 1:100 ; SCALE (m)

EASTERN ELEVATION

SCALE 1:100

SOUTHERN ELEVATION

SCALE 1:100

NORTHERN ELEVATION

SCALE 1:100

SLAB & FOOTINGS TO

SUPPLIERS SPECS.

6.5m

6.5

m

6.5m

6.5m

6.5m

6.5m

3.00

APPENDIX CITEM 13.1

Page 1420JUN2017

Page 5: MACLEAY STREET...2017/06/20  · 30/01/2017 1 of 5 6XLWH :LOOLDP 6WUHHW 32 %R[ 3RUW 0DFTXDULH 16: $%1 7HOHSKRQH )DFVLPLOH (PDLO PDLO#KRSFRQ FRP DX HOPKINS SUBJECT TO COUNCIL APPROVAL,

SW

SW

SW

SW

SW

SW

SW

SW

SW

SW

SW SW

SW

SW SW

SW SW

SW

D

G

E

EX

IS

TIN

G H

OU

SE

DR

AIN

AG

E

IN

ST

ALL

KE

RB

AD

AP

TO

R

Ø150mm

uP

VC

IN

ST

AL

L F

UT

UR

E

ST

OR

MW

AT

ER

JU

NC

TIO

N &

KE

RB

A

DA

PT

OR

IN

ST

AL

L F

UT

UR

E

HO

US

E S

ER

VIC

E

DISCONNECT EXISTING

JUNCTION - CONNECT

TO NEW RESIDENCE

CONSTRUCT JUNCTION

- RECONNECT TO

EXISTING HOUSE

EXISTING HOUSE SERVICE

NEW HOUSE SERVICE

NO

RT

H S

TR

EE

T

Hopkins Consultants Pty Ltd

C

Liability limited by a scheme approved under

7082-06

Professional Standards Legislation

PROPOSED SUBDIVISION

SERVICES PLAN

NORTH STREET, FREDERICKTON

GA

1:200

DEVELOPMENT APPLICATION FOR SUBDIVISIONAND MULTI-DWELLING HOUSING

MACLEAY STREET, FREDERICKTON

A3

A

30/01/2017

4 of 5

Suite 1 / 109 William Street · PO Box 1556 Port Macquarie NSW 2444 · ABN 27 055 060 878

Telephone: 02 6583 6722 · Facsimile: 02 6584 9009 · Email: [email protected]

HOPKINS210 64

Full Size 1:200 ; SCALE (m)

APPENDIX CITEM 13.1

Page 1520JUN2017