machine operator priorities for linac 2 and 3 g bellodi, be-abp-hsl g bellodi, bi- boss-2 meeting,...

15
Machine operator priorities for Linac 2 and 3 G Bellodi, BE-ABP-HSL G Bellodi, BI- BOSS-2 meeting , 10 June 2015

Upload: helen-hardy

Post on 22-Dec-2015

213 views

Category:

Documents


0 download

TRANSCRIPT

G Bellodi, BI- BOSS-2 meeting , 10 June 2015

Machine operator priorities for Linac 2

and 3 G Bellodi, BE-ABP-HSL

G Bellodi, BI- BOSS-2 meeting , 10 June 2015

LBE

LBSLTB

LT

LTL LT

LTE

LALILP

Linac 2 Tunnel

PS Tunnel (inflector) – Entrance from PSB

ITH

LINAC2

G Bellodi, BI- BOSS-2 meeting , 10 June 2015

Instruments Status Usage In layout DB Stops beam?

comments

LI.BCT02

operational

Critical for machine

setup, operation,

MDs

yesYes, through

Linac2 SIS watchdog

located at several

positions along the

Linac + TRIC cards

acquisition system

LI.BCT06LA.BCT07

LT.BCT10LT.BCT20

LT.BCT30

LT.BCT40

LTB.BCT50

LTB.BCT60

BI.BCT10

Beam current transformers: intensity measurements

G Bellodi, BI- BOSS-2 meeting , 10 June 2015

Instruments Status Usage In layout DB Stops beam? comments

LT.BPM10

operational

Critical for machine

setup, operation,

MDs

yes no

During LS1 the pick ups

were replaced with

stripline detectors - compatible with Linac4.

LT.BPM20

LT.BPM30

LT.BPM40

LT.BPM50

LTB.BPM10

LTB.BPM20

LTB.BPM30

BI.BPM00

BI.BPM10

BI.BPM20

BI.BPM30

Pick-ups: Linac2 to PSB trajectory steering

G Bellodi, BI- BOSS-2 meeting , 10 June 2015

Instruments Status Usage In layout DB Stops beam?

comments

BLM1

operational MDs no no

LHC type Moveable

devicesNot in main

control system ,

BLM2

BLM3

BLM4

BLM5

BLM6

BLM7

BLMs

1, 2 low energy, in tanks, strong shielding

G Bellodi, BI- BOSS-2 meeting , 10 June 2015

LTL-LTE measurement lines at Linac exit

G Bellodi, BI- BOSS-2 meeting , 10 June 2015

Measurement Lines – LTE

Measurement Lines – LTL

Name Instrument Status Usage In layout DB Stops beam? comments

LTE.BCT15 TransfoOperational in principle MDs, setup no no

Not heavily used, most often found not working

LTE.MSG10HV?

Semgrid (fixed)

Name Instrument Status Usage In layout DB Stops beam? comments

LTS.BCT12 Transfo

Operational in principle MDs, setup no no

Not heavily used, most often found not working

LTS.BCT14 Transfo

LTS.MSGV10? Semgrid (fixed)

SPEM GM class maintenance needs follow up

G Bellodi, BI- BOSS-2 meeting , 10 June 2015

LBE, LBS measurement lines off BHZ40 magnet

G Bellodi, BI- BOSS-2 meeting , 10 June 2015

LBE

Name Instrument status usage In layout DB Stops beam?

LBE.BCT64 transo Operational

MDs, setup, debugging yes no

LBE.BCT65 Transfo Operational

LBE.BCT66 Transfo Ions / not used

LBE.MSGH10 Semgrid Operational

LBE.MSGV10 Semgrid Operational, pneumatic

LBE.MSGHV20 Semgrid Taken out

LBS

Name Instrument Status usage In layout DB Stops beam?

LBS.BCT62 Transfo Operational

MDs, setup, debugging yes no

LBS.BCT63 Transfo Ions/ not used

LBS.MSGV50 semgrid Operational, fixed with rotational

degree

G Bellodi, BI- BOSS-2 meeting , 10 June 2015

LINAC3

G Bellodi, BI- BOSS-2 meeting , 10 June 2015

Faraday cups Name status Usage In layout DB Stops beam?

ITL.MFC01 Removed

Critical for machine setup, operation, MDs

No By default, and also in case of motor malfunction

ITL.MFC02

operationalITM.MFC01

Instruments Status Usage In layout DB Stops beam?

ITL.BCT05

operationalCritical for

machine setup, operation, MDs

no noITF.BCT15

ITF.BCT25

ITH.BCT41

Transformers

G Bellodi, BI- BOSS-2 meeting , 10 June 2015

Semgrids

Name Status Usage In layout DB Stops beam?

ITL.BSF03HV

operational Machine setup, MDs no

In case of malfunction of the motor system

ITM.BSF04HV

ITF.BSF02HV

ITF.BSG03HV

ITF.BSG04HV

ITF.BSG05HV

ITH.BSG11HV

ITH.BSG15HV

2 pick-ups are installed in the Linac3 inter-tanks: not operational but still installed – could potentially cause a vacuum leak

G Bellodi, BI- BOSS-2 meeting , 10 June 2015

Pepper pot

Pepper Pot

Control Cabinet

BEAM

Pepper pot plateMCP, PHOSPHOR

Mirror

Camera

Instruments Status Usage In layout DB Stops beam? comments

XXX (no official name yet)

Installed in April, under

commissioningmachine setup, operation, MDs no

Yes, by default or in case of malfunction

Standalone controls, to be

integrated

G Bellodi, BI- BOSS-2 meeting , 10 June 2015

LIU plans for LBS upgrade

• replacement of the spectrometer magnet (reuse identical magnets from Linac2)• exchange of the power converter (from Linac4)• controls modifications to power convertors and beam diagnostics in the part of the transfer

line in common with Linac4, to allow simpler line sharing between H- and ions.

G Bellodi, BI- BOSS-2 meeting , 10 June 2015

Layout database: Linac2: LI, LA, LTE, LTL missing from layout database - only LT, LTB, BI, LBS, LBE are present Linac3 not present in the database

Beam off: Equipment failures that could cause a prolonged beam unavailability mainly related to vacuum leaks or malfunction of pneumatic arms for intercepting devices – SIS watchdog can be modified/bypassed in case of BCT failure in order to resume operation

Criticality: Linac3 – very little instrumentation and lack of redundancy what is there is mostly critical for operation

Software: need guaranteed maintenance of BI standalone applications and work towards integration of standalone controls

Conclusions