m5 east freeway · australia tel no: 1300 364 946 fax no: 1300 668 763 email [email protected]...
TRANSCRIPT
DATA REPORT Report NO: DAT11823
Report Issue Date: 28/04/2017
Report Prepared by: John Leung Page: i
ECOTECH PTY LTD. ABN: 32 005 752 081 1492 Ferntree Gully Rd, Knoxfield VIC. 3180. AUSTRALIA Tel No: 1300 364 946 Fax No: 1300 668 763 Email [email protected] WEB www.ecotech.com
M5 EAST FREEWAY AMBIENT AIR QUALITY MONITORING DATA
REPORT 8 – AIR MONITORING REPORT VALIDATED DATA FOR F1, M1
MARCH 2017
Including Section 1
Validated Summary Data for F1, M1 - MARCH 2017 Section 2
Validated Graphical Representations for F1, M1 - MARCH 2017 Section 3
Validated Meteorological Data for F1, M1 - MARCH 2017 Section 4
Validated Daily Average of 1 Hour Readings Data for F1, M1 - MARCH 2017 Section 5
Valid Data Exception Reports for F1, M1 - MARCH 2017 Appendix
Calibration Reports for F1, M1 - MARCH 2017
DATA REPORT Report NO: DAT11823
Report Issue Date: 28/04/2017
Report Prepared by: John Leung Page: ii
ECOTECH PTY LTD. ABN: 32 005 752 081 1492 Ferntree Gully Rd, Knoxfield VIC. 3180. AUSTRALIA Tel No: 1300 364 946 Fax No: 1300 668 763 Email [email protected] WEB www.ecotech.com
CONTENTS
Report 1 Cover Page i Contents Pages ii Section 1 Divider 1 F1, M1 Summary Table 2 F1, M1 NO2 Maxima Table 3 Section 2 Divider 4 F1 CO 8hr Rolling Av. Graph 5 F1 CO Scatter plot 6 F1 NO2 1 hr Av. Graph (ppm and µg/m³) 7 F1 NO2 Scatter plot 8 F1 TEOM PM10 Daily Av. Graph 9 F1 TEOM PM10 Daily Av. Scatter plot 10 M1 CO 8hr Rolling Av. Graph 11 M1 CO Scatter plot 12 M1 NO2 1 hr Av. Graph (ppm and µg/m³) 13 M1 NO2 Scatter plot 14 M1 TEOM PM10 Daily Av. Graph 15 M1 TEOM PM10 Daily Av. Scatter plot 16 Section 3 Divider 17 F1 Ambient Temperature Graph 18 F1 Wind Rose Graph 19 F1 Wind Speed Graph 20 M1 Ambient Temperature Graph 21 M1 Wind Rose Graph 22 M1 Wind Speed Graph 23 Section 4 Divider 24 F1 Daily Average of 1 hour Readings 25 M1 Daily Average of 1 hour Readings 26 Section 5 Divider 27 F1 Daily Zero and Span Summary Report 28 F1 Valid Data Exception Report 29 M1 Daily Zero and Span Summary Report 30 M1 Valid Data Exception Report 31
Appendix 32
DATA REPORT Report NO: DAT11823
Report Issue Date: 28/04/2017
Report Prepared by: John Leung
Page: 1 of 32
ECOTECH PTY LTD. ABN: 32 005 752 081 1492 Ferntree Gully Rd, Knoxfield VIC. 3180. AUSTRALIA Tel No: 1300 364 946 Fax No: 1300 668 763 Email [email protected] WEB www.ecotech.com
M5 EAST FREEWAY AMBIENT AIR QUALITY MONITORING DATA
SECTION 1
Validated Summary Data for F1, M1
MARCH 2017
Report NO: DAT11823
Page: 2 of 32
ECOTECH PTY LTD. ABN: 32 005 752 081 1492 Ferntree Gully Rd, Knoxfield VIC. 3180. AUSTRALIA Tel No: 1300 364 946 Fax No: 1300 668 763 Email [email protected] WEB www.ecotech.com
PM10 ( µg/m³ ) PM10 ( µg/m³ )
DATEDaily Av. of the 24
8HR Avg's CO
Max. 1HR Av. During
the 24HR period
Daily Av. of the 24 1HR
Avg's PM10
Daily Av. Of the 24
8HR Avg's CO
Max. 1HR Av. During
the 24HR period
Daily Av. of the 24 1HR
Avg's PM10
MUAP goal is 50 µg/m³ MUAP goal is 50 µg/m³
1/03/2017 39 0.019 60 0.029 0.35 0.74 14.6 39 0.019 55 0.027 10.7
2/03/2017 41 0.020 66 0.032 0.34 1.01 11.9 42 0.020 60 0.029 0.32 0.53 10.1
3/03/2017 38 0.019 58 0.028 0.33 0.59 13.1 34 0.016 45 0.022 0.24 0.41 10.4
4/03/2017 26 0.013 41 0.020 0.32 0.50 10.7 26 0.013 48 0.024 0.28 0.50 10.7
5/03/2017 21 0.010 30 0.014 0.18 0.25 9.6 19 0.009 32 0.016 0.25 0.36 9.4
6/03/2017 32 0.015 49 0.024 0.11 0.30 18.6 17 0.008 25 0.012 0.13 0.18 14.9
7/03/2017 35 0.017 56 0.027 0.13 0.29 16.3 24 0.012 38 0.018 0.18 0.34 13.6
8/03/2017 46 0.022 60 0.029 0.26 0.51 17.9 42 0.021 56 0.027 0.26 0.49 16.7
9/03/2017 42 0.021 62 0.030 0.28 0.51 21.9 37 0.018 66 0.032 0.27 0.47 18.2
10/03/2017 38 0.019 49 0.024 0.27 0.73 20.2 31 0.015 43 0.021 0.28 0.49 17.1
11/03/2017 31 0.015 47 0.023 0.22 1.32 16.1 32 0.016 46 0.022 0.28 0.53 13.5
12/03/2017 20 0.010 39 0.019 0.44 1.65 20.4 23 0.011 38 0.018 0.36 0.74 19.8
13/03/2017 33 0.016 70 0.034 0.24 0.93 27.7 33 0.016 70 0.034 0.22 0.40 22.8
14/03/2017 32 0.016 58 0.028 0.18 0.62 17.7 34 0.017 54 0.026 0.21 0.34 17.1
15/03/2017 20 0.010 49 0.024 0.15 0.56 16.7 26 0.013 46 0.022 0.18 0.38 15.6
16/03/2017 19 0.009 28 0.014 0.16 0.29 11.3 24 0.012 33 0.016 0.19 0.31 12.2
17/03/2017 29 0.014 50 0.024 0.19 0.28 18.2 15 0.007 24 0.012 0.14 0.20 14.9
18/03/2017 20 0.010 34 0.017 0.21 0.32 18.9 26 0.013 46 0.022 0.25 0.47 18.1
19/03/2017 10 0.005 17 0.008 0.13 0.13 15.4 14 0.007 26 0.013 0.19 0.26 15.2
20/03/2017 17 0.008 31 0.015 0.14 0.29 18.4 19 0.009 32 0.016 0.15 0.37 19.7
21/03/2017 29 0.014 63 0.030 0.18 0.63 17.6 30 0.015 63 0.031 0.18 0.49 17.4
22/03/2017 37 0.018 72 0.035 0.30 0.71 11.1 49 0.024 110 0.054 0.40 0.78 14.2
23/03/2017 38 0.018 50 0.024 0.26 0.58 10.8 30 0.014 46 0.022 0.25 0.45 8.5
24/03/2017 41 0.020 51 0.025 0.29 0.52 14.7 36 0.017 59 0.029 0.26 0.88 12.8
25/03/2017 24 0.012 41 0.020 0.20 0.32 14.5 27 0.013 39 0.019 0.17 0.33 13.9
26/03/2017 21 0.010 34 0.016 0.22 0.66 14.7 25 0.012 56 0.027 0.29 0.48 14.4
27/03/2017 23 0.011 44 0.022 0.21 0.71 13.5 30 0.015 43 0.021 0.19 0.45 15.6
28/03/2017 46 0.022 74 0.036 0.29 0.42 27.2 33 0.016 48 0.023 0.21 0.32 20.8
29/03/2017 40 0.020 69 0.034 0.26 1.17 25.3 43 0.021 84 0.041 0.26 0.67 26.4
30/03/2017 40 0.020 65 0.032 0.54 1.17 17.5 36 0.018 87 0.042 0.39 1.20 18.5
31/03/2017 38 0.018 60 0.029 0.18 0.42 15.3 22 0.011 37 0.018 0.08 0.20 11.6
Monthly Average 31 ( 0.015 ) 51 ( 0.025 ) 0.24 0.62 16.7 30 ( 0.014 ) 50 ( 0.024 ) 0.24 0.47 15.3
% of valid data 95.4 95.4 99.9 95.3 93.4 99.9
Notes:
Sample Days Lowest values for month in bold italic type
Week Ends Highest values for month in bold type
MUAP goal is 256 µg/m³
(0.125ppm)
MUAP goal is 256 µg/m³
(0.125ppm)
NO2 ug/m³ (ppm)CO ( ppm )NO2 ug/m³ (ppm)
Daily Av. Of the 24 1HR
Avg's NO2
Max. 1HR Av. During the
24HR period
Daily Av. Of the 24 1HR
Avg's NO2
Max. 1HR Av. During the
24HR period
F1 M1
M5 EAST FREEWAY (Validated) March-17
CO ( ppm )
Report NO: DAT11823
Page: 3 of 32
ECOTECH PTY LTD. ABN: 32 005 752 081 1492 Ferntree Gully Rd, Knoxfield VIC. 3180. AUSTRALIA Tel No: 1300 364 946 Fax No: 1300 668 763 Email [email protected] WEB www.ecotech.com
DATE
NO2 Max. 1Hr
Av. During the
24Hr period
(µg/m3)
TimeWind Speed 1Hr
Ave for NO2 1Hr
Max (m/sec)
Wind Direction
1Hr Ave for NO2
1Hr Max (Deg)
Relative
Humidity 1Hr
Ave for NO2 1Hr
Max (%)
Sigma Theta 1Hr
Ave for NO2 1Hr
Max (Deg)
NO2 Max. 1Hr
Av. During the
24Hr period
(µg/m3)
TimeWind Speed 1Hr
Ave for NO2 1Hr
Max (m/sec)
Wind Direction
1Hr Ave for NO2
1Hr Max (Deg)
Relative
Humidity 1Hr
Ave for NO2 1Hr
Max (%)
Sigma Theta 1Hr
Ave for NO2 1Hr
Max (Deg)
1/03/2017 60 10:00 0.8 140 92 39 55 8:00 0.6 79 100 53
2/03/2017 66 11:00 1.6 133 68 46 60 11:00 1.7 163 67 45
3/03/2017 58 7:00 1.3 154 100 32 45 7:00 1.2 171 100 42
4/03/2017 41 5:00 1.0 172 101 28 48 6:00 1.2 158 98 44
5/03/2017 30 7:00 0.5 211 91 46 32 6:00 1.1 234 82 63
6/03/2017 49 6:00 0.6 212 74 47 25 6:00 3.4 213 66 32
7/03/2017 56 5:00 0.7 200 73 41 38 7:00 2.7 217 88 26
8/03/2017 60 12:00 2.1 148 58 35 56 13:00 1.0 136 55 67
9/03/2017 62 9:00 1.9 136 70 36 66 4:00 1.5 156 66 35
10/03/2017 49 6:00 0.5 209 88 57 43 19:00 1.1 197 75 47
11/03/2017 47 21:00 0.1 115 82 20 46 22:00 0.6 333 74 30
12/03/2017 39 23:00 0.1 138 87 36 38 1:00 0.6 324 82 35
13/03/2017 70 12:00 1.4 123 47 44 70 12:00 1.1 152 47 71
14/03/2017 58 6:00 1.2 102 82 34 54 7:00 1.0 110 77 42
15/03/2017 49 6:00 0.3 170 101 70 46 6:00 0.3 310 100 56
16/03/2017 28 7:00 1.5 52 97 28 33 11:00 1.4 89 96 49
17/03/2017 50 1:00 0.4 191 92 53 24 7:00 3.5 192 90 27
18/03/2017 34 8:00 2.5 147 93 29 46 5:00 1.5 140 98 52
19/03/2017 17 18:00 2.2 62 90 30 26 7:00 1.9 72 97 34
20/03/2017 31 6:00 1.1 59 97 17 32 5:00 1.3 43 92 26
21/03/2017 63 18:00 0.4 97 99 53 63 17:00 0.4 133 101 66
22/03/2017 72 14:00 2.4 134 59 28 110 14:00 1.4 153 58 38
23/03/2017 50 12:00 1.3 179 77 43 46 6:00 2.8 196 81 29
24/03/2017 51 9:00 1.2 172 78 39 59 7:00 1.8 213 89 29
25/03/2017 41 23:00 0.1 212 87 79 39 23:00 0.5 312 81 44
26/03/2017 34 1:00 0.2 130 94 65 56 11:00 0.7 130 51 64
27/03/2017 44 22:00 0.2 103 92 79 43 23:00 0.4 186 89 58
28/03/2017 74 11:00 1.4 166 73 29 48 11:00 2.5 173 73 42
29/03/2017 69 18:00 1.1 62 78 24 84 22:00 0.1 329 80 76
30/03/2017 65 8:00 0.3 186 86 64 87 6:00 4.3 180 86 40
31/03/2017 60 6:00 0.5 209 73 54 37 6:00 2.1 243 68 26
Notes:
Sample Days
Week Ends
M1
March-2017
NO2 Validated Data for the Maximum Hourly Average per day and the associated Meteorological data for that hour
M5 EAST FREEWAY
F1
DATA REPORT Report NO: DAT11823
Report Issue Date: 28/04/2017
Report Prepared by: John Leung Page: 4 of 32
ECOTECH PTY LTD. ABN: 32 005 752 081 1492 Ferntree Gully Rd, Knoxfield VIC. 3180. AUSTRALIA Tel No: 1300 364 946 Fax No: 1300 668 763 Email [email protected] WEB www.ecotech.com
M5 EAST FREEWAY
AMBIENT AIR QUALITY MONITORING DATA
SECTION 2
Validated Graphical Representations for F1, M1
MARCH 2017
DATA REPORT Report NO: DAT11823
Report Issue Date: 28/04/2017
Report Prepared by: John Leung Page: 5 of 32
ECOTECH PTY LTD. ABN: 32 005 752 081 1492 Ferntree Gully Rd, Knoxfield VIC. 3180. AUSTRALIA Tel No: 1300 364 946 Fax No: 1300 668 763 Email [email protected] WEB www.ecotech.com
CO 8hr avg. ppm Station: M5 Flatrock Rd (F1)
Figure 1: CO 8 hour rolling average for F1
DATA REPORT Report NO: DAT11823
Report Issue Date: 28/04/2017
Report Prepared by: John Leung Page: 6 of 32
ECOTECH PTY LTD. ABN: 32 005 752 081 1492 Ferntree Gully Rd, Knoxfield VIC. 3180. AUSTRALIA Tel No: 1300 364 946 Fax No: 1300 668 763 Email [email protected] WEB www.ecotech.com
CO concentrations for wind speed between 0.4 and 10 m/s
Station: M5 Flatrock Rd (F1)
Figure 2: CO scatter plot for F1
DATA REPORT Report NO: DAT11823
Report Issue Date: 28/04/2017
Report Prepared by: John Leung Page: 7 of 32
ECOTECH PTY LTD. ABN: 32 005 752 081 1492 Ferntree Gully Rd, Knoxfield VIC. 3180. AUSTRALIA Tel No: 1300 364 946 Fax No: 1300 668 763 Email [email protected] WEB www.ecotech.com
Nitrogen Dioxide µg/m³ Station: M5 Flatrock Rd (F1)
Figure 3: NO2 hourly average for F1
DATA REPORT Report NO: DAT11823
Report Issue Date: 28/04/2017
Report Prepared by: John Leung Page: 8 of 32
ECOTECH PTY LTD. ABN: 32 005 752 081 1492 Ferntree Gully Rd, Knoxfield VIC. 3180. AUSTRALIA Tel No: 1300 364 946 Fax No: 1300 668 763 Email [email protected] WEB www.ecotech.com
NO2 concentrations for wind speed between 0.4 and 10 m/s
Station: M5 Flatrock Rd (F1)
Figure 4: NO2 scatter plot for F1
DATA REPORT Report NO: DAT11823
Report Issue Date: 28/04/2017
Report Prepared by: John Leung Page: 9 of 32
ECOTECH PTY LTD. ABN: 32 005 752 081 1492 Ferntree Gully Rd, Knoxfield VIC. 3180. AUSTRALIA Tel No: 1300 364 946 Fax No: 1300 668 763 Email [email protected] WEB www.ecotech.com
TEOM PM10 µg/m³ Station: M5 Flatrock Rd (F1)
Figure 5: PM10 daily average for F1
DATA REPORT Report NO: DAT11823
Report Issue Date: 28/04/2017
Report Prepared by: John Leung Page: 10 of 32
ECOTECH PTY LTD. ABN: 32 005 752 081 1492 Ferntree Gully Rd, Knoxfield VIC. 3180. AUSTRALIA Tel No: 1300 364 946 Fax No: 1300 668 763 Email [email protected] WEB www.ecotech.com
Station: M5 Flatrock Rd (F1)
PM10 concentrations for wind speed between 0.4 and 10 m/s
Figure 6: PM10 scatter plot for F1
DATA REPORT Report NO: DAT11823
Report Issue Date: 28/04/2017
Report Prepared by: John Leung Page: 11 of 32
ECOTECH PTY LTD. ABN: 32 005 752 081 1492 Ferntree Gully Rd, Knoxfield VIC. 3180. AUSTRALIA Tel No: 1300 364 946 Fax No: 1300 668 763 Email [email protected] WEB www.ecotech.com
CO 8hr avg. ppm Station: M5 W Botany St (M1)
Figure 7: CO 8 hour rolling average for M1
DATA REPORT Report NO: DAT11823
Report Issue Date: 28/04/2017
Report Prepared by: John Leung Page: 12 of 32
ECOTECH PTY LTD. ABN: 32 005 752 081 1492 Ferntree Gully Rd, Knoxfield VIC. 3180. AUSTRALIA Tel No: 1300 364 946 Fax No: 1300 668 763 Email [email protected] WEB www.ecotech.com
CO concentrations for wind speed between 0.4 and 10 m/s
Station: M5 W Botany St (M1)
Figure 8: CO scatter plot for M1
DATA REPORT Report NO: DAT11823
Report Issue Date: 28/04/2017
Report Prepared by: John Leung Page: 13 of 32
ECOTECH PTY LTD. ABN: 32 005 752 081 1492 Ferntree Gully Rd, Knoxfield VIC. 3180. AUSTRALIA Tel No: 1300 364 946 Fax No: 1300 668 763 Email [email protected] WEB www.ecotech.com
Nitrogen Dioxide µg/m³ Station: M5 W Botany St (M1)
Figure 9: NO2 hourly average for M1
DATA REPORT Report NO: DAT11823
Report Issue Date: 28/04/2017
Report Prepared by: John Leung Page: 14 of 32
ECOTECH PTY LTD. ABN: 32 005 752 081 1492 Ferntree Gully Rd, Knoxfield VIC. 3180. AUSTRALIA Tel No: 1300 364 946 Fax No: 1300 668 763 Email [email protected] WEB www.ecotech.com
NO2 concentrations for wind speed between 0.4 and 10 m/s
Station: M5 W Botany St (M1)
Figure 10: NO2 scatter plot for M1
DATA REPORT Report NO: DAT11823
Report Issue Date: 28/04/2017
Report Prepared by: John Leung Page: 15 of 32
ECOTECH PTY LTD. ABN: 32 005 752 081 1492 Ferntree Gully Rd, Knoxfield VIC. 3180. AUSTRALIA Tel No: 1300 364 946 Fax No: 1300 668 763 Email [email protected] WEB www.ecotech.com
TEOM PM10 µg/m³ Station: M5 W Botany St (M1)
Figure 11: PM10 daily average for M1
DATA REPORT Report NO: DAT11823
Report Issue Date: 28/04/2017
Report Prepared by: John Leung Page: 16 of 32
ECOTECH PTY LTD. ABN: 32 005 752 081 1492 Ferntree Gully Rd, Knoxfield VIC. 3180. AUSTRALIA Tel No: 1300 364 946 Fax No: 1300 668 763 Email [email protected] WEB www.ecotech.com
Station: M5 W Botany St (M1)
PM10 concentrations for wind speed between 0.4 and 10 m/s
Figure 12: PM10 scatter plot for M1
DATA REPORT Report NO: DAT11823
Report Issue Date: 28/04/2017
Report Prepared by: John Leung Page: 17 of 32
ECOTECH PTY LTD. ABN: 32 005 752 081 1492 Ferntree Gully Rd, Knoxfield VIC. 3180. AUSTRALIA Tel No: 1300 364 946 Fax No: 1300 668 763 Email [email protected] WEB www.ecotech.com
M5 EAST FREEWAY AMBIENT AIR QUALITY MONITORING DATA
SECTION 3
Validated Meteorological Data for F1, M1
MARCH 2017
DATA REPORT Report NO: DAT11823
Report Issue Date: 28/04/2017
Report Prepared by: John Leung Page: 18 of 32
ECOTECH PTY LTD. ABN: 32 005 752 081 1492 Ferntree Gully Rd, Knoxfield VIC. 3180. AUSTRALIA Tel No: 1300 364 946 Fax No: 1300 668 763 Email [email protected] WEB www.ecotech.com
Figure 13: Hourly average temperature for F1
DATA REPORT Report NO: DAT11823
Report Issue Date: 28/04/2017
Report Prepared by: John Leung Page: 19 of 32
ECOTECH PTY LTD. ABN: 32 005 752 081 1492 Ferntree Gully Rd, Knoxfield VIC. 3180. AUSTRALIA Tel No: 1300 364 946 Fax No: 1300 668 763 Email [email protected] WEB www.ecotech.com
Station: M5 Flatrock Rd (F1)
Figure 14: Wind rose for F1
DATA REPORT Report NO: DAT11823
Report Issue Date: 28/04/2017
Report Prepared by: John Leung Page: 20 of 32
ECOTECH PTY LTD. ABN: 32 005 752 081 1492 Ferntree Gully Rd, Knoxfield VIC. 3180. AUSTRALIA Tel No: 1300 364 946 Fax No: 1300 668 763 Email [email protected] WEB www.ecotech.com
Wind Speed Vector m/s Station: M5 Flatrock Rd (F1)
Figure 15: Hourly Average wind speed for F1
DATA REPORT Report NO: DAT11823
Report Issue Date: 28/04/2017
Report Prepared by: John Leung Page: 21 of 32
ECOTECH PTY LTD. ABN: 32 005 752 081 1492 Ferntree Gully Rd, Knoxfield VIC. 3180. AUSTRALIA Tel No: 1300 364 946 Fax No: 1300 668 763 Email [email protected] WEB www.ecotech.com
Figure 16: Hourly Average temperature for M1
DATA REPORT Report NO: DAT11823
Report Issue Date: 28/04/2017
Report Prepared by: John Leung Page: 22 of 32
ECOTECH PTY LTD. ABN: 32 005 752 081 1492 Ferntree Gully Rd, Knoxfield VIC. 3180. AUSTRALIA Tel No: 1300 364 946 Fax No: 1300 668 763 Email [email protected] WEB www.ecotech.com
Station: M5 W Botant St (M1)
Figure 17: Wind rose for M1
DATA REPORT Report NO: DAT11823
Report Issue Date: 28/04/2017
Report Prepared by: John Leung Page: 23 of 32
ECOTECH PTY LTD. ABN: 32 005 752 081 1492 Ferntree Gully Rd, Knoxfield VIC. 3180. AUSTRALIA Tel No: 1300 364 946 Fax No: 1300 668 763 Email [email protected] WEB www.ecotech.com
Wind Speed Vector m/s Station: M5 W Botant St (M1)
Figure 18: Hourly Average wind speed for M1
DATA REPORT Report NO: DAT11823
Report Issue Date: 28/04/2017
Report Prepared by: John Leung Page: 24 of 32
ECOTECH PTY LTD. ABN: 32 005 752 081 1492 Ferntree Gully Rd, Knoxfield VIC. 3180. AUSTRALIA Tel No: 1300 364 946 Fax No: 1300 668 763 Email [email protected] WEB www.ecotech.com
M5 EAST FREEWAY AMBIENT AIR QUALITY MONITORING DATA
SECTION 4
Validated Daily Average of 1 hour readings for F1, M1
MARCH 2017
DATA REPORT Report NO: DAT11823
Report Issue Date: 28/04/2017
Report Prepared by: John Leung Page: 25 of 32
ECOTECH PTY LTD. ABN: 32 005 752 081 1492 Ferntree Gully Rd, Knoxfield VIC. 3180. AUSTRALIA Tel No: 1300 364 946 Fax No: 1300 668 763 Email [email protected] WEB www.ecotech.com
M5 East FreeWay AQMS - March 2017
Daily Average of 1 Hour Readings (Validated)
M5 Flatrock Rd (F1)
NO2
µg/m³
CO
ppm
PM10
µg/m³
WS
m/s
WD
Deg
SIGMA
Deg
SRAD
W/m²
RH
%
01/03/2017 39 0.38 14.6 1.1 139 28 179 92
02/03/2017 41 0.32 11.9 0.6 112 41 241 86
03/03/2017 38 0.35 13.1 1.1 154 32 130 97
04/03/2017 26 0.29 10.7 1.3 165 37 104 96
05/03/2017 21 0.15 9.6 0.8 201 54 123 83
06/03/2017 32 0.11 18.6 1.4 186 48 306 66
07/03/2017 35 0.14 16.3 1.4 179 39 153 83
08/03/2017 46 0.28 17.9 1.2 153 41 144 77
09/03/2017 42 0.28 21.9 1.3 164 37 194 75
10/03/2017 38 0.28 20.2 1.2 171 42 257 73
11/03/2017 31 0.29 16.1 0.7 123 42 313 69
12/03/2017 20 0.27 20.4 1.1 53 39 327 71
13/03/2017 33 0.23 27.7 1.5 71 34 237 77
14/03/2017 32 0.21 17.7 1.6 83 27 99 85
15/03/2017 20 0.14 16.7 1.9 71 29 168 86
16/03/2017 19 0.18 11.3 1.4 57 34 93 94
17/03/2017 29 0.18 18.2 2.1 179 40 132 91
18/03/2017 20 0.23 18.9 2.6 138 29 151 92
19/03/2017 10 0.11 15.4 2.1 68 27 161 91
20/03/2017 17 0.14 18.4 1.5 47 27 168 85
21/03/2017 29 0.21 17.6 0.7 52 37 146 89
22/03/2017 37 0.29 11.1 0.4 160 55 183 91
23/03/2017 38 0.30 10.8 0.9 184 43 91 88
24/03/2017 41 0.27 14.7 0.9 154 42 209 86
25/03/2017 24 0.19 14.5 0.4 36 49 165 78
26/03/2017 21 0.19 14.7 0.7 70 46 268 80
27/03/2017 23 0.24 13.5 1.1 40 36 288 82
28/03/2017 46 0.27 27.2 1.1 167 42 94 84
29/03/2017 40 0.35 25.3 0.7 52 44 249 82
30/03/2017 40 0.42 17.5 1.2 173 39 37 97
31/03/2017 37 0.22 15.3 1.4 179 44 271 70
% Data Capture 95.4 95.4 99.9 99.7 99.7 99.7 99.9 99.9
Table 3: Daily Average data for F1
DATA REPORT Report NO: DAT11823
Report Issue Date: 28/04/2017
Report Prepared by: John Leung Page: 26 of 32
ECOTECH PTY LTD. ABN: 32 005 752 081 1492 Ferntree Gully Rd, Knoxfield VIC. 3180. AUSTRALIA Tel No: 1300 364 946 Fax No: 1300 668 763 Email [email protected] WEB www.ecotech.com
M5 East FreeWay AQMS - March 2017
Daily Average of 1 Hour Readings (Validated)
M5 W Botany St (M1)
NO2
µg/m³
CO
ppm
PM10
µg/m³
WS
m/s
WD
Deg
SIGMA
Deg
SRAD
W/m²
RH
%
01/03/2017 39 0.32 10.7 0.7 155 43 169 93
02/03/2017 42 0.32 10.1 0.5 150 44 245 85
03/03/2017 34 0.23 10.4 1.0 170 41 125 97
04/03/2017 26 0.29 10.7 1.5 183 46 75 92
05/03/2017 19 0.24 9.4 2.2 222 44 100 79
06/03/2017 17 0.11 14.9 3.5 198 39 320 62
07/03/2017 24 0.21 13.6 2.9 193 30 149 77
08/03/2017 42 0.25 16.7 1.0 163 51 155 71
09/03/2017 37 0.29 18.2 1.6 176 42 179 66
10/03/2017 31 0.29 17.1 1.5 206 40 245 68
11/03/2017 32 0.27 13.5 0.5 204 33 344 64
12/03/2017 23 0.33 19.8 1.2 42 33 335 68
13/03/2017 33 0.21 22.8 1.1 74 44 237 71
14/03/2017 34 0.22 17.1 1.1 94 39 81 85
15/03/2017 26 0.17 15.6 1.4 82 39 190 83
16/03/2017 24 0.22 12.2 1.3 57 32 88 92
17/03/2017 15 0.11 14.9 3.7 189 27 122 88
18/03/2017 26 0.28 18.1 1.6 148 40 130 92
19/03/2017 14 0.19 15.2 1.7 74 37 139 89
20/03/2017 19 0.14 19.7 1.6 56 34 164 82
21/03/2017 30 0.22 17.4 0.7 46 40 145 87
22/03/2017 49 0.43 14.2 0.4 246 36 205 89
23/03/2017 30 0.24 8.5 2.4 194 27 83 86
24/03/2017 35 0.24 12.8 1.2 182 36 217 81
25/03/2017 27 0.20 13.9 0.5 22 36 156 73
26/03/2017 25 0.27 14.4 0.5 51 35 289 75
27/03/2017 30 0.20 15.6 0.9 44 35 295 78
28/03/2017 33 0.22 20.8 1.8 184 39 83 82
29/03/2017 43 0.33 26.4 0.4 54 48 250 79
30/03/2017 36 0.30 18.5 4.1 189 33 28 93
31/03/2017 22 0.10 11.6 2.8 196 32 265 67
% Data Capture 95.3 93.4 99.9 99.6 99.6 99.6 79.6 100.0
Table 4: Daily Average data for M1
DATA REPORT Report NO: DAT11823
Report Issue Date: 28/04/2017
Report Prepared by: John Leung Page: 27 of 32
ECOTECH PTY LTD. ABN: 32 005 752 081 1492 Ferntree Gully Rd, Knoxfield VIC. 3180. AUSTRALIA Tel No: 1300 364 946 Fax No: 1300 668 763 Email [email protected] WEB www.ecotech.com
M5 EAST FREEWAY AMBIENT AIR QUALITY MONITORING DATA
SECTION 5
Validation Reports for F1, M1
MARCH 2017
DATA REPORT Report NO: DAT11823
Report Issue Date: 28/04/2017
Report Prepared by: John Leung Page: 28 of 32
ECOTECH PTY LTD. ABN: 32 005 752 081 1492 Ferntree Gully Rd, Knoxfield VIC. 3180. AUSTRALIA Tel No: 1300 364 946 Fax No: 1300 668 763 Email [email protected] WEB www.ecotech.com
Date
NO Zero NO2 Zero NOx Zero NOx Span NOx Prec CO Zero CO Span CO Prec
1/03/2017 2 0 2 380 388 0.00 40.87 40.05
2/03/2017 1 0 2 380 388 0.01 40.89 40.05
3/03/2017 1 0 1 381 388 0.01 40.95 40.05
4/03/2017 1 0 2 386 388 0.02 39.99 40.05
5/03/2017 1 0 1 384 388 -0.02 40.02 40.05
6/03/2017 1 0 1 383 388 -0.02 40.00 40.05
7/03/2017 1 0 1 385 388 0.00 40.04 40.05
8/03/2017 1 0 1 384 388 0.08 40.15 40.05
9/03/2017 0 1 1 383 388 0.03 40.15 40.05
10/03/2017 1 0 1 384 388 0.05 40.22 40.05
11/03/2017 1 0 1 382 388 0.02 40.30 40.05
12/03/2017 1 1 2 383 388 0.05 40.44 40.05
13/03/2017 1 1 2 384 388 0.04 40.33 40.05
14/03/2017 1 0 1 383 388 0.01 40.09 40.05
15/03/2017 1 0 1 381 388 0.01 40.11 40.05
16/03/2017 1 1 1 382 388 0.02 40.10 40.05
17/03/2017 2 0 2 382 388 0.03 40.17 40.05
18/03/2017 1 0 1 381 388 0.03 40.11 40.05
19/03/2017 1 1 2 379 388 -0.01 40.10 40.05
20/03/2017 2 0 2 381 388 -0.03 40.01 40.05
21/03/2017 2 0 2 380 388 -0.05 39.99 40.05
22/03/2017 1 1 1 380 388 0.01 40.13 40.05
23/03/2017 1 1 2 379 388 0.02 40.05 40.05
24/03/2017 2 0 2 378 388 0.04 40.09 40.05
25/03/2017 1 1 1 378 388 0.04 40.13 40.05
26/03/2017 1 0 1 377 388 0.01 40.11 40.05
27/03/2017 1 0 1 378 388 0.02 40.04 40.05
28/03/2017 2 0 2 378 388 0.02 40.15 40.05
29/03/2017 2 0 2 378 388 -0.01 40.10 40.05
30/03/2017 2 0 2 378 388 -0.03 40.24 40.05
31/03/2017 1 1 2 374 388 0.10 40.21 40.05
Table 5: Daily Zero and Span Summary Report for F1
M5 East Freeway Air Quality Monitoring Station, F1
Daily Zero and Span Summary Report
March-17
NOx ( ppb ) CO ( ppm )
DATA REPORT Report NO: DAT11823
Report Issue Date: 28/04/2017
Report Prepared by: John Leung Page: 29 of 32
ECOTECH PTY LTD. ABN: 32 005 752 081 1492 Ferntree Gully Rd, Knoxfield VIC. 3180. AUSTRALIA Tel No: 1300 364 946 Fax No: 1300 668 763 Email [email protected] WEB www.ecotech.com
Start Date End Date Reason Change Details
Blank in
Summary
Yes/No
02/03/17 17:00 31/03/17 15:05 Intermittent data transmission errors All channels No
03/03/17 08:05 03/03/17 09:50Scheduled monthly maintenance - instrument
calibration and stabilisationNO,NO2, NOX, CO No
19/03/17 00:45 29/03/17 00:45Intermittent instrument stabilisation following
overnight check for 5 to 10 minutesCO No
Table 6: Valid Data Exception Report for F1
M5 East Motorway
F1 Valid Data Exception Report
March-17
Note: The F1 site is not optimal for solar radiation due to shadows from multiple obstructions.
DATA REPORT Report NO: DAT11823
Report Issue Date: 28/04/2017
Report Prepared by: John Leung Page: 30 of 32
ECOTECH PTY LTD. ABN: 32 005 752 081 1492 Ferntree Gully Rd, Knoxfield VIC. 3180. AUSTRALIA Tel No: 1300 364 946 Fax No: 1300 668 763 Email [email protected] WEB www.ecotech.com
Date
NO Zero NO2 Zero NOx Zero NOx Span NOx Prec CO Zero CO Span CO Prec
1/03/2017 0 0 0 373 391 -0.08 39.98 40.00
2/03/2017 0 1 1 393 391 -0.06 40.06 40.00
3/03/2017 0 0 0 392 391 -0.18 39.85 40.00
4/03/2017 0 0 0 392 391 -0.06 40.01 40.00
5/03/2017 0 0 0 -0.05
6/03/2017 0 0 0 390 391 -0.03 40.02 40.00
7/03/2017 0 0 0 391 391 -0.06 40.00 40.00
8/03/2017 0 0 0 392 391 -0.06 39.98 40.00
9/03/2017 0 0 0 392 391 -0.04 40.02 40.00
10/03/2017 0 0 0 391 391 -0.04 40.06 40.00
11/03/2017 0 0 1 390 391 -0.05 40.09 40.00
12/03/2017 0 0 0 390 391 -0.05 40.13 40.00
13/03/2017 0 0 0 390 391 -0.06 39.98 40.00
14/03/2017 0 0 0 391 391 -0.09 39.94 40.00
15/03/2017 0 0 0 391 391 -0.06 39.96 40.00
16/03/2017 0 0 0 390 391 -0.07 39.97 40.00
17/03/2017 0 0 0 390 391 -0.08 39.95 40.00
18/03/2017 0 0 0 390 391 -0.06 39.91 40.00
19/03/2017 0 0 0 390 391 0.02 39.93 40.00
20/03/2017 0 0 0 389 391 -0.09 39.87 40.00
21/03/2017 0 0 0 389 391 -0.14 39.86 40.00
22/03/2017 0 0 0 389 391 -0.05 39.99 40.00
23/03/2017 0 0 0 389 391 -0.05 40.01 40.00
24/03/2017 0 0 0 389 391 -0.09 39.93 40.00
25/03/2017 0 0 0 390 391 -0.07 40.01 40.00
26/03/2017 0 0 0 389 391 -0.04 40.01 40.00
27/03/2017 0 0 0 389 391 -0.10 39.91 40.00
28/03/2017 0 0 0 389 391 -0.07 39.97 40.00
29/03/2017 0 0 0 389 391 -0.06 39.99 40.00
30/03/2017 0 0 1 389 391 -0.10 40.05 40.00
31/03/2017 0 0 1 387 391 -0.07 39.96 40.00
M5 East Freeway Air Quality Monitoring Station, M1
Daily Zero and Span Summary Report
March-17
NOx ( ppb ) CO ( ppm )
Table 7: Daily Zero & Span for M1
DATA REPORT Report NO: DAT11823
Report Issue Date: 28/04/2017
Report Prepared by: John Leung Page: 31 of 32
ECOTECH PTY LTD. ABN: 32 005 752 081 1492 Ferntree Gully Rd, Knoxfield VIC. 3180. AUSTRALIA Tel No: 1300 364 946 Fax No: 1300 668 763 Email [email protected] WEB www.ecotech.com
Start Date End Date Reason Change Details
Blank in
Summary
Yes/No
01/03/17 00:00 01/04/17 00:00Shadow on sensor, daily between approximately
06:20 - 07:30 and 15:20 - 18:05SR Yes
01/03/17 00:55 31/03/17 01:25Intermittent instrument stabilisation following overnight
calibration check for approximately 5 to 30 minutesCO No
01/03/17 06:25 31/03/17 22:20 Intermittent data transmission errors All channels No
01/03/17 09:00 01/03/17 12:10Scheduled monthly maintenance - instrument calibration and
stabilisationCO,NO,NO2, NOX Yes
01/03/17 11:15 01/03/17 12:00Scheduled monthly maintenance - instrument calibration and
stabilisationPM10 No
04/03/17 13:00 28/03/17 18:00 Intermittent instrument fault - wind speed spike WS,WD,Sig No
05/03/17 00:00 05/03/17 00:35 Automatic overnight span not triggered CO,NO,NO2, NOX Yes
M5 East Motorway
M1 Valid Data Exception Report
March-17
Table 8: Valid Data Exception Report for M1
DATA REPORT Report NO: DAT11823
Report Issue Date: 28/04/2017
Report Prepared by: John Leung Page: 32 of 32
ECOTECH PTY LTD. ABN: 32 005 752 081 1492 Ferntree Gully Rd, Knoxfield VIC. 3180. AUSTRALIA Tel No: 1300 364 946 Fax No: 1300 668 763 Email [email protected] WEB www.ecotech.com
M5 EAST FREEWAY
AMBIENT AIR QUALITY MONITORING DATA
APPENDIX
Calibration Reports for F1, M1
MARCH 2017