There are some of the important alarms which should be kept in the mind during work in the NOC are compiled in the table below. The reasons of alarms appearing are mentioned. ALARM NAME SOURCE NAME REASON AND POSSIBILITIES Cell PTP BVC Faulty BSC Gb link down NSE FAULTY BSC Gb link down Extern Figure Sensor1 Alarm BSC Rectifier Failure Extern Figure Sensor3 Alarm BSC Rectifier Alarm Extern Figure Sensor4 Alarm BSC AC Failure Extern Figure Sensor5 Alarm BSC Door Open Alarm MTP3 Link Unavailable BSC Either Signaling link are faulty or deactivated. Check it from BSC from MAINTAIN MTP3 LINK. May be some of A interface E1 is faulty on which it is define. Local NM Connection Broken BSC OMCR OML link down so we are not able to perform any task in the BSC. Loss of E1/T1 Signals ( LOS ) BSC Check whether some Ater or A interface E1 is faulty or degraded. Main Board Out of Position BSC BSC alarm chest cable been disconnected or power of BSC alarm box gets down. Must focus on this alarm if it comes for more than 30 min than make sure to clear it on urgent basis. LAPD OML FAULT BTS Site is down check the reason from history either transmission or Generator issue LAPD ALARM BTS It will be on some of TRX or can be on all TRX check child alarms like SFP Port alarms. CELL OUT OF SERVICE ALARM BTS Either the site is locked or some TRX of that sector gets down or SFP Port not consistent. SFP PORT INCONSISTENCY ALARM BTS the SFP Port is not inserted properly CPRI may be damaged Wrong configuration ALARM NAME SOURCE NAME REASON AND POSSIBILITIES

Upload: riadelectro

Post on 25-Oct-2015

25 views

Category:

Documents


5 download

TRANSCRIPT

Page 1: M2000 and BSC Alarm Detail 1

There are some of the important alarms which should be kept in the mind during work in the

NOC are compiled in the table below. The reasons of alarms appearing are mentioned.

ALARM NAME SOURCE NAME REASON AND POSSIBILITIES

Cell PTP BVC Faulty BSC Gb link down

NSE FAULTY BSC Gb link down

Extern Figure Sensor1 Alarm BSC Rectifier Failure

Extern Figure Sensor3 Alarm BSC Rectifier Alarm

Extern Figure Sensor4 Alarm BSC AC Failure

Extern Figure Sensor5 Alarm BSC Door Open Alarm

MTP3 Link Unavailable BSC Either Signaling link are faulty or deactivated. Check it from BSC from MAINTAIN MTP3 LINK. May be some of A interface E1 is faulty on which it is define.

Local NM Connection Broken BSC OMCR OML link down so we are not able to perform any task in the BSC.

Loss of E1/T1 Signals ( LOS ) BSC Check whether some Ater or A interface E1 is faulty or degraded.

Main Board Out of Position BSC BSC alarm chest cable been disconnected or power of BSC alarm box gets down. Must focus on this alarm if it comes for more than 30 min than make sure to clear it on urgent basis.

LAPD OML FAULT BTS Site is down check the reason from history either transmission or Generator issue

LAPD ALARM BTS It will be on some of TRX or can be on all TRX check child alarms like SFP Port alarms.

CELL OUT OF SERVICE ALARM BTS Either the site is locked or some TRX of that sector gets down or SFP Port not consistent.

SFP PORT INCONSISTENCY ALARM

BTS the SFP Port is not inserted properly

CPRI may be damaged

Wrong configuration

ALARM NAME SOURCE NAME REASON AND POSSIBILITIES

Page 2: M2000 and BSC Alarm Detail 1

Diversity Receive Channel Alarms

BTS Cross connected cable (diversity cables) among the DRFU get damaged or not properly inserted.

No AC input alarm BTS AC power of the BTS gets down

Cell PS Service Faulty BTS GPRS of the site or sector not working

Clock Reference Abnormal Alarm

BTS BTS is not synchronizing BSC Clock

Fan Subassembly Communication Alarm

BTS BTS Fan alarm cable is not properly inserted or FAN is not working or FAN power cable is damaged or not inserted properly.

TRX VSWR ALARM BTS This alarm is service effecting due to impedance mismatching this alarms come. Check the jumper connector, feeder connector or antenna port to remove the alarm.