Features & Benefits M10 (lite) Multi-parameter Patient Monitor 12.1" high resolution color TFT display 6 display interfaces, maximum 10 waveforms display 13 arrhythmia analysis and 15 concentration titration analysis 168 hours trend recall Auto video and audio alarming Protection against interference of defibrillation and high-frequency electrotome All-lead ECG display simultaneously Network function Application: operating room, ICU, NICU, CCU, general ward : ECG, NIBP, SPO2, RESP, TEMP, HR Standard configuration : thermo- recorder, central monitoring system, wall mount, trolley Options Patient Monitor M10 (lite) Multi-parameter Patient Monitor Safety standard IEC-60601-1, CE marked Power supply AC: 100~240V, 50/60Hz DC: 14.4V Packing information Size: 313mm×301mm×163mm Weight: 5kgs(N.W), 7kgs(G.W) Display 12.1″ color TFT Maximum 10 waveforms in full screen Power/standby indicator and battery indicator Battery Rechargeable, regular working time more than 120 minutes Lasting 5 minutes after first alarm of low battery Recorder( Optional) Built-in, thermal array Recording mode: manual, alarm and timing Paper width: 50mm Recording width: 48mm Recording track: two channels Recording speed:25mm/s Recall Trend recall: 168 hours trend recall Alarm event recall: 100 alarm events ECG Lead Input: 3-lead, 5-lead Lead method: I; II; III; avR; avL; avF; V I; II; III Gain: X0.125; X0.25; X0.5; X1.0; X2.0 Sweep speed: 12.5mm/s, 25mm/s, 50mm/s Differential input impedance: 5MΩ HR Range: 15~350bpm Resolution: 1bpm Precision: ±1% or ±1bpm, prior to larger Sensitivity: 0.2mVpp RESP Method: RA-LL impedance method RESP measurement & alarming : Adult: 1~120rpm Neonatal/ pediatric: 1~150rpm Resolution: 1rpm Accuracy: ±2rpm Differential input impedance: over 2.5MΩ, RA-LL lead Apnea alarm: 10~40 seconds NIBP Measurement method: automatic vibration Work mode: Manual / Automatic Unit: mmHg/ Kpa optional Measurement range: Adult: SYS 40~270mmHg DIA 10~210mmHg MEAN 20~230mmHg Pediatric: SYS 40~200mmHg DIA 10~150mmHg MEAN 20~165mmHg Neonatal: SYS 40-135mmHg DIA 10~100mmHg MEAN 20~110mmHg Over-pressure protection: Adult: 300±10%mmHg Pediatric: 240±10%mmHg Neonatal: 150±10%mmHg Resolution: 1mmHg Precision: ±5% or 8mmHg SPO2 Measurement & alarm range: 0~100% Resolution: 1% Precision: 70~100%, 0%~69% no definition PR and alarm range: 25~240bpm PR resolution: 1bpm PR precision: ±3bpm TEMP Measurement & alarm range: 0~50Resolution: 0.1Precision: ±0.1Channel: 2 channels, giving display of T1, T2 and T Shenzhen Carewell Electronics Co., Ltd. Specification subject to change without prior notice Add: 1A-2/F, Building 29, District B, Tanglang Industrial Zone, Taoyuan Street Nanshan, Shenzhen 518055, P.R. China Tel: +86-755-8617 0389 Fax: +86-755-8617 0478 E-mail: [email protected] Website: www.carewell.com.cn

Upload: dhirajkumar1

Post on 09-Dec-2015

219 views

Category:

Documents


3 download

DESCRIPTION

medical equipment

TRANSCRIPT

Page 1: M10 lite

Features & Benefits

M10(lite) Multi-parameter Patient Monitor

● 12.1" high resolution color TFT display

● 6 display interfaces, maximum 10 waveforms display

● 13 arrhythmia analysis and 15 concentration titration analysis

● 168 hours trend recall

● Auto video and audio alarming

● Protection against interference of defibrillation and high-frequency electrotome

● All-lead ECG display simultaneously

● Network function

● Application: operating room, ICU, NICU, CCU, general ward

: ECG, NIBP, SPO2, RESP, TEMP, HRStandard configuration: thermo- recorder, central monitoring system, wall mount, trolleyOptions

Patient Monitor

M10(lite)Multi-parameter Patient Monitor

Safety standardIEC-60601-1, CE marked

Power supplyAC: 100~240V, 50/60HzDC: 14.4V

Packing informationSize: 313mm×301mm×163mmWeight: 5kgs(N.W), 7kgs(G.W)

Display

12.1″ color TFT Maximum 10 waveforms in full screenPower/standby indicator and battery indicator

BatteryRechargeable, regular working time more than 120

minutesLasting 5 minutes after first alarm of low battery

Recorder(Optional)Built-in, thermal arrayRecording mode: manual, alarm and timingPaper width: 50mmRecording width: 48mmRecording track: two channelsRecording speed:25mm/s

RecallTrend recall: 168 hours trend recallAlarm event recall: 100 alarm events

ECG Lead Input: 3-lead, 5-leadLead method: I; II; III; avR; avL; avF; V I; II; III Gain: X0.125; X0.25; X0.5; X1.0; X2.0Sweep speed: 12.5mm/s, 25mm/s, 50mm/s

Differential input impedance: ≥ 5MΩ

HRRange: 15~350bpmResolution: 1bpmPrecision: ±1% or ±1bpm, prior to larger

Sensitivity: ≥0.2mVpp

RESP Method: RA-LL impedance methodRESP measurement & alarming : Adult: 1~120rpm Neonatal/ pediatric: 1~150rpmResolution: 1rpmAccuracy: ±2rpmDifferential input impedance: over 2.5MΩ, RA-LL leadApnea alarm: 10~40 seconds

NIBPMeasurement method: automatic vibrationWork mode: Manual / AutomaticUnit: mmHg/ Kpa optionalMeasurement range:Adult: SYS 40~270mmHg DIA 10~210mmHg MEAN 20~230mmHgPediatric: SYS 40~200mmHg DIA 10~150mmHg MEAN 20~165mmHgNeonatal: SYS 40-135mmHg DIA 10~100mmHg MEAN 20~110mmHgOver-pressure protection: Adult: 300±10%mmHgPediatric: 240±10%mmHgNeonatal: 150±10%mmHgResolution: 1mmHgPrecision: ±5% or 8mmHg

SPO2 Measurement & alarm range: 0~100%Resolution: 1%Precision: 70~100%, 0%~69% no definitionPR and alarm range: 25~240bpmPR resolution: 1bpmPR precision: ±3bpm

TEMP

Measurement & alarm range: 0~50℃

Resolution: 0.1℃

Precision: ±0.1℃

Channel: 2 channels, giving display of T1, T2 and △T