Features & Benefits
M10(lite) Multi-parameter Patient Monitor
● 12.1" high resolution color TFT display
● 6 display interfaces, maximum 10 waveforms display
● 13 arrhythmia analysis and 15 concentration titration analysis
● 168 hours trend recall
● Auto video and audio alarming
● Protection against interference of defibrillation and high-frequency electrotome
● All-lead ECG display simultaneously
● Network function
● Application: operating room, ICU, NICU, CCU, general ward
: ECG, NIBP, SPO2, RESP, TEMP, HRStandard configuration: thermo- recorder, central monitoring system, wall mount, trolleyOptions
Patient Monitor
M10(lite)Multi-parameter Patient Monitor
Safety standardIEC-60601-1, CE marked
Power supplyAC: 100~240V, 50/60HzDC: 14.4V
Packing informationSize: 313mm×301mm×163mmWeight: 5kgs(N.W), 7kgs(G.W)
Display
12.1″ color TFT Maximum 10 waveforms in full screenPower/standby indicator and battery indicator
BatteryRechargeable, regular working time more than 120
minutesLasting 5 minutes after first alarm of low battery
Recorder(Optional)Built-in, thermal arrayRecording mode: manual, alarm and timingPaper width: 50mmRecording width: 48mmRecording track: two channelsRecording speed:25mm/s
RecallTrend recall: 168 hours trend recallAlarm event recall: 100 alarm events
ECG Lead Input: 3-lead, 5-leadLead method: I; II; III; avR; avL; avF; V I; II; III Gain: X0.125; X0.25; X0.5; X1.0; X2.0Sweep speed: 12.5mm/s, 25mm/s, 50mm/s
Differential input impedance: ≥ 5MΩ
HRRange: 15~350bpmResolution: 1bpmPrecision: ±1% or ±1bpm, prior to larger
Sensitivity: ≥0.2mVpp
RESP Method: RA-LL impedance methodRESP measurement & alarming : Adult: 1~120rpm Neonatal/ pediatric: 1~150rpmResolution: 1rpmAccuracy: ±2rpmDifferential input impedance: over 2.5MΩ, RA-LL leadApnea alarm: 10~40 seconds
NIBPMeasurement method: automatic vibrationWork mode: Manual / AutomaticUnit: mmHg/ Kpa optionalMeasurement range:Adult: SYS 40~270mmHg DIA 10~210mmHg MEAN 20~230mmHgPediatric: SYS 40~200mmHg DIA 10~150mmHg MEAN 20~165mmHgNeonatal: SYS 40-135mmHg DIA 10~100mmHg MEAN 20~110mmHgOver-pressure protection: Adult: 300±10%mmHgPediatric: 240±10%mmHgNeonatal: 150±10%mmHgResolution: 1mmHgPrecision: ±5% or 8mmHg
SPO2 Measurement & alarm range: 0~100%Resolution: 1%Precision: 70~100%, 0%~69% no definitionPR and alarm range: 25~240bpmPR resolution: 1bpmPR precision: ±3bpm
TEMP
Measurement & alarm range: 0~50℃
Resolution: 0.1℃
Precision: ±0.1℃
Channel: 2 channels, giving display of T1, T2 and △T