m-150s-av fuel pump - amazon s3

12
921422-20A TABLE OF CONTENTS General Information .................................................... 2 Safety Instructions ...................................................... 2 Installation .................................................................. 3 Operation .................................................................... 4 Maintenance ............................................................... 4 Repair ......................................................................... 4 Troubleshooting .......................................................... 8 Specifications ............................................................. 9 Parts and Service ....................................................... 9 Illustrated Parts List .................................................. 10 Warranty ................................................................... 12 02/14 To the owner... Congratulations on receiving your GPI ® fuel pump. We are pleased to provide you with a system designed to give you maximum reliability and efficiency. Your fuel pump is designed for use with aviation gasoline (AVGAS) and kerosene grade (JET A). Please take all due precautions when handling these flammable liquids. Your safety is important to us. Also, to assure the longest possible service life, it is important that you follow the operation and maintenance procedures outlined in this manual. We are proud to provide you with a quality product and dedicated support. Together with your conscientious use, we are sure that you will obtain years of safe, dependable service. Victor Lukic, President Great Plains Industries, Inc. DO NOT RETURN THIS PRODUCT TO THE STORE! Please contact GPI before returning any product. If you are missing parts or experience problems with your installation, our Customer Support Department will be happy to assist you: 800-835-0113 or 316-686-7361 M-150S-AV Fuel Pump Owner’s Manual SAVE THESE INSTRUCTIONS

Upload: others

Post on 06-May-2022

4 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: M-150S-AV Fuel Pump - Amazon S3

921422-20A

TABLE OF CONTENTS

General Information .................................................... 2Safety Instructions ...................................................... 2Installation .................................................................. 3Operation .................................................................... 4Maintenance ............................................................... 4Repair ......................................................................... 4Troubleshooting .......................................................... 8Specifications ............................................................. 9Parts and Service ....................................................... 9Illustrated Parts List .................................................. 10Warranty ................................................................... 12

02/14

To the owner...

Congratulations on receiving your GPI® fuel pump. We are pleased to provide you with a system designed to give you maximum reliability and efficiency.

Your fuel pump is designed for use with aviation gasoline (AVGAS) and kerosene grade (JET A). Please take all due precautions when handling these flammable liquids. Your safety is important to us.

Also, to assure the longest possible service life, it is important that you follow the operation and maintenance procedures outlined in this manual. We are proud to provide you with a quality product and dedicated support. Together with your conscientious use, we are sure that you will obtain years of safe, dependable service.

Victor Lukic, PresidentGreat Plains Industries, Inc.

DO NOT RETURN THIS PRODUCT TO THE STORE!

Please contact GPI before returning any product. If you are missing parts or experience problems with your installation, our Customer Support Department will be happy to assist you:

800-835-0113 or 316-686-7361

M-150S-AV Fuel PumpOwner’s Manual

SAVE THESE INSTRUCTIONS

Page 2: M-150S-AV Fuel Pump - Amazon S3

2 M-150S-AV 921422-20A

It is your responsibility to:• Know and follow applicable national, state and local

safety codes pertaining to installing and operating electrical equipment for use with flammable liquids.

• Know and follow all safety precautions when handling petroleum fuels.

• Ensure that all equipment operators have access to adequate instructions concerning safe operating and maintenance procedures.

Observe all safety precautions concerning safe handling of petroleum fuels.

To ensure safe operation, all fuel transfer systems must be properly grounded. Proper grounding means a continu-ous metal-to-metal contact from one component to the next, including tank, bung, pump, meter, filter, hose and nozzle. Care should be taken to ensure proper ground-ing during initial

installation and after any service or repair procedures. For your safety, please take a moment to review the warnings below.

To prevent physical injury, observe precautions against fire or explosion when dispensing fuel. Do not operate the system in the presence of any source of ignition including running or hot engines, lighted cigarettes or gas or electric heaters.

Observe precautions against electrical shock when oper-ating the system. Serious or fatal shock can result from operating electrical equipment in damp or wet locations.

Inspect external pump wiring regularly to make sure it is correctly attached to the battery. To avoid electrical shock, use extra care when connecting the pump to power.

Avoid prolonged skin contact with petroleum fuels. Use protective goggles, gloves and aprons in case of splash-ing or spills. Change saturated clothing and wash skin promptly with soap and water.

Observe precautions against electrical shock when servicing the pump. Always disconnect power before repairing or servicing. Never apply electrical power to the system when any of the coverplates are removed.

If using solvent to clean pump components or tank, ob-serve the solvent manufacturer’s recommendations for safe use and disposal.

• Forground-basedrefuelingonly.Donotuseinorontheaircraft.

• Forusewithaviationgasoline(AVGAS100LL)andkerosenegrade(JETA).

• UsershouldconsultNFPA407StandardforAircraftFuelServicingforsafetyrequirementsduringgroundfuelservicingofaircraftusingliquidpetroleumfuels.Thisproducthasnoactualorimpliedcompliancewiththisstandard.

WARNING

GENERAL INFORMATIONThe purpose of this manual is to assist you in installing, operating and maintaining your GPI pump. This manual covers 12-volt DC electric gear pump model M-150S-AV.Model M-150S-AV should be connected to a 12-volt DC power source.Do not attempt connection of this pump to a 115-volt AC or 230-volt AC power source.

For ground-based refueling only. Do not use in or on the aircraft.

WARNING

An automatic bypass valve prevents pressure build up when the pump is on with the nozzle closed. To avoid damage, do not run the pump more than 10 minutes with the nozzle closed.The duty cycle of this pump is 30 minutes ON and 30 minutes OFF. Allow the pump to cool for 30 minutes.

This pump is designed for use only with aviation gasoline (AVGAS 100LL) and kerosene grade (JET A). Do not use this pump for dispensing any fluids other than those for which it was designed. To do so may damage pump components and will void the warranty.

This pump is designed to operate on a typical DC automo-tive electrical system. The pump is designed to operate with the appropriate DC voltage at the motor leads and the ratings are determined at this voltage. Performance may vary due to length of power cord, battery condition or output from the vehicle charging system that will affect system voltage.

Do not leave the system running without fluids. “Dry run-ning” can damage the pump.

Do not pump the tank completely dry, as contaminants from the bottom of the tank may enter the pump.

SAFETY INFORMATION

The following safety alert symbols are used in this manual.

DANGER DANGER indicates a hazardous situation which, if not avoided, will result in death or serious injury.

WARNING WARNING i nd ica tes a potentially hazardous situation which, if not avoid-ed, could result in death or serious injury.

CAUTION CAUTION i nd i ca tes a potentially hazardous situation which, if not avoid-ed, may result in minor or moderate injury.

Page 3: M-150S-AV Fuel Pump - Amazon S3

3921422-20A M-150S-AV

INSTALLATION

This pump is designed to self-prime with dry gears. If you require a greater initial prime height, coat the gears with fluid by removing the plug on the top of the pump and pour a small quantity of motor oil into the gear cavity. Replace the plug and try again. A foot valve with pressure relief may be needed to maintain prime.

Make sure all threaded fuel connections are wrapped with three to four turns of thread tape or a pipe thread sealant approved for use with petroleum fuels.

Appropriate hose, nozzle and suction pipe not included. Items must meet NFPA 407 guidelines.

Install Bung Adapter and Suction Pipe• Tighten the bung adapter snugly into the fuel tank.

• Place the union ring gasket into the inlet fitting on the bottom of the pump.

• Thread a suitable suction pipe into the inlet fitting and tighten until snug. Suction pipe should be within 1/2 inch from the bottom of the tank.

Install Pump on Tank• Clean the tank interior of all dirt and foreign material.

• Insert pump and suction pipe into the tank opening. (Figure 1)

FIGURE 1

GPI®

• Place the pump on the bung adapter and tighten the union ring securely with a pipe wrench. Make sure the union ring is not cross-threaded.

• To prevent pressure buildup and possible fuel leaks through the nozzle, make sure the tank is vented. A vent cap rated at 3 psi or less is recommended.

Install Electrical ConnectionsA grounding connection is provided. It is identified as a green colored binding head screw in the electrical cavity.

Model M-150S-AV should be connected to a 12-volt DC power source.

Do not attempt connection of this pump to a 115-volt AC or 230-volt AC power source.

For installation in unclassified areas, the supplied power cord, fuse and strain relief grip may be used.

NOTE: These components have not been evaluated as part of the UL Listed Equipment and are not intended for use in a Hazardous (Classified) Location.

To install the power cord, remove the electrical cover-plate. (Figure 2)

FIGURE 2

If necessary, trim the power cord to the desired length. Strip 3 to 4 inches (7.5 to 10 cm) of outer insulation from the power cord end. Then strip 1/2 inch (1.3 cm) of insulation from the power cord wires.

Slide the strain relief grip onto the power cord so that the threaded end of the strain relief grip faces the stripped power wires. (Figure 3)

FIGURE 3

Insert the power cord through the 1/2 inch NPT connec-tion on the back of the pump. (Figure 4)

FIGURE 4

Using wire nuts, connect the black wire to the black wire and the red wire to the red in the pump’s electrical cavity. Position the wires inside the electrical cavity and tighten the strain relief grip securely. Make sure surfaces are clean. Install the coverplate and tighten securely.

Page 4: M-150S-AV Fuel Pump - Amazon S3

4 M-150S-AV 921422-20A

Motor ProtectorThe pump contains a motor protector that provides added protection against motor damage. It must be reset manually.

If the motor protector trips, reset by turning the switch OFF. Let the pump cool then turn ON again. If the motor protector trips again, see the Troubleshooting Section of this manual.

MAINTENANCE

This pump is designed for minimum maintenance. Motor bearings are sealed and require no lubrication. Inspect the pump and components regularly for fuel leaks and make sure the hose and power cord are in good condi-tion. Keep the pump exterior clean to help identify leaks.

Do not use this pump for water, chemicals or herbicides. Dispensing any fluid other than those listed in this manual will damage the pump. Use of the pump with unauthor-ized fluids will void the warranty.

To Clean or Replace StrainerTurn the pump off and disconnect from power. Remove the strainer coverplate. (Figure 5) Remove the inlet strainer and inspect for damage or clogs. Clean the strainer with a soft-bristled brush and solvent. If the strainer is very dirty, compressed air may be used. If damaged, replace the strainer.

FIGURE 5

GPI®

Place the strainer in the cavity. Clean the coverplate and O-ring. Coat the O-ring lightly with grease. Ensure the coverplate O-ring is properly seated and tighten the strainer coverplate.

REPAIR

Carefully inspect all parts for wear or damage. Replace components, as necessary. The Illustrated Parts List gives information on replacement parts and kits.

Review the Safety Instructions before proceeding.

Observe precautions against electrical shock when servicingthepump.Alwaysdisconnectpowerbeforerepairingorservic-ing.Neverapplyelectricalpowertothesystemwhenanyofthecoverplatesareremoved.

WARNING

Carefullyroutethepowercordtothebattery,protectingthepowercordfromhotsurfaces,sharpedgesoranythingthatcoulddam-agethepowercord,resultinginashortcircuit.

Afuseisprovidedtoprotectthepowercordandmotor.Installfuseintheredwireofthepowercordascloseaspossibletothebat-tery.Connecttheredwireofthefusetothepositive(ungrounded)sideofbattery.Connectblackwire to thenegative (grounded)sideofthebattery.

Failuretofollowtheseinstructionscouldresultindeath,seriousinjuryorlossofequipmentduetoshortcircuit,fireorexplosion.

WARNING

If thepump is tobe installed inaHazardous (Classified) loca-tion,itmustbeinstalledbyalicensedelectricianandconformtoNationalFireProtectionAssociation(NFPA)codes30and70.Youastheowner,areresponsibleforseeingthattheinstallationandoperationofyourpumpcomplieswithNFPAcodesaswellasanyapplicablestateandlocalcodes.Rigidconduitmustbeusedtoinstallwiring.Notethattheleadwiresarefactory-sealedisolatingthemotorfromthejunctionbox.

Failuretofollowthesewiringinstructionsmayresultindeathorseriousinjuryfromshock,fireorexplosion.

DANGER

OPERATIONALWAYS FOLLOW SAFETY PRECAUTIONS WHEN OPERATING THIS EQUIPMENT. REVIEW THE SAFETY INSTRUCTIONS. Before each use, repair leaks around seals or connections. Make sure hoses are in good condition and connections are tight. Make sure the work area is dry. MAKE SURE THE PUMP IS PROPERLY GROUNDED. Repair any corroded or damaged wiring before use. Ensure the tank contains enough fuel. Make sure the fuel is not contaminated with debris.

Dispense FuelTurn the pump on by pushing up the switch lever. Insert the nozzle into the receiving tank and squeeze the handle to start fuel flow. When done, release the nozzle handle, turn the pump off, and return the nozzle to its holder.

This pump is designed to be self-priming. If fuel is not delivered within 15 to 20 seconds, turn the pump off and refer to the priming information in the Troubleshooting Section.

An automatic bypass valve prevents pressure buildup when the pump is on with the nozzle closed. To avoid pump damage, do not run the pump for more than 10 minutes with the nozzle closed.

MAINTENANCE

Page 5: M-150S-AV Fuel Pump - Amazon S3

5921422-20A M-150S-AV

Avoidprolongedskincontactwithpetroleumfuels.Useprotectivegoggles,glovesandapronsincaseofsplashingorspills.Changesaturatedclothingandwashskinpromptlywithsoapandwater.

WARNING

Remove Pump from Tank• Turn the pump OFF and disconnect from power.

• Turn the union ring counterclockwise to release the inlet fitting.

• Lift the pump and suction pipe straight up from the bung adapter.

• Elevate the nozzle and hose to allow excess fuel to drain into the tank.

• Wipe the entire system with a clean cloth.

Service O-RingsA Wet Seal Kit contains all seals for your pump and should be on hand when performing repairs. Old seals may then be replaced with new seals.

In general, when inspecting O-rings, look for breaks, wear and signs of deterioration, such as swelling. Replace, as necessary. Before seating, coat O-rings with light grease.

Replace Gears and Drive Key• Turn the pump OFF and disconnect from power.

• Remove the gear coverplate. (Figure 6)

FIGURE 6

• Lift the drive key and gears from the pump. (Figure 7)

FIGURE 7

• Inspect the gears and key for wear and damage. Replace, as necessary.

• Wipe the gear cavity with a clean cloth.

• Replace the gears. Make sure they turn freely.

• Replace the drive key.

• Make sure the gear coverplate O-ring is securely in place. Tighten the coverplate to the housing.

Clean or Replace Bypass Poppet• Turn the pump OFF and disconnect from power.

• Using a drive ratchet or extension, remove the pipe plug from the top outlet port. (Figure 8)

FIGURE 8

• Remove the gear coverplate and O-ring from the pump housing.

• Lift the drive key and two gears from the pump.

• To clean the bypass poppet:

a. With a clean cloth, wipe the poppet cavity through the top outlet port.

b. Push down on the poppet until the poppet O-ring is exposed inside the housing. (Figure 9)

FIGURE 9

c. Using a clean cloth, rotate the poppet and clean it thoroughly.

Page 6: M-150S-AV Fuel Pump - Amazon S3

6 M-150S-AV 921422-20A

Replace Power Switch• Turn the pump OFF and disconnect from power.

• Remove the switch coverplate from the pump housing. (Figure 12)

FIGURE 12

• Remove the torx head screw, then remove the switch assembly. (Figure 13)

FIGURE 13

• Remove one pump wire from the back of the switch and one wire from the circuit protector.

• Install a new switch by reversing the above procedure. Insert the switch assembly into the pump cavity. Place the red wire between the circuit breaker and the wall of the pump. Make sure the O-ring is seated properly before tightening the switch coverplate.

NOTE: For the proper operation of the switch lever and cam, attach the mounting plate to the switch with a clearance of 0.175 or about 3/16 inch. (Figure 14)

FIGURE 14

• To remove or replace the bypass poppet:

a. As above, push down on the poppet until the O-ring is exposed.

b. Remove the O-ring with a small screwdriver or similar tool. Take care not to damage the poppet or O-ring. (Figure 10)

GPI®

O-ring Groove➤

Poppet O-ring➤

Spring➤

FIGURE 10

c. From inside the housing, use a small screwdriver to push the poppet and spring through the top outlet port. (Figure 11)

FIGURE 11

d. Wipe the poppet and gear cavities with a clean cloth.

e. Replace the poppet, O-ring, and spring, as neces-sary.

NOTE: Replace O-ring if damaged, swollen, or loose-fitting.

• To assemble, place the spring and poppet into the poppet cavity through the top outlet port. Compress the poppet into the housing until the poppet appears in the lower chamber. (see Figure 10) Coat the O-ring lightly with grease and slip over the poppet head. Make sure the O-ring is well-seated.

• Push on the poppet through the top outlet port to make sure it moves freely.

• Install the pipe plug again.

• Replace the gears and drive key. Make sure gears turn freely with the key removed.

• Make sure the gear coverplate O-ring is in place. Tighten the coverplate to the pump housing.

Page 7: M-150S-AV Fuel Pump - Amazon S3

7921422-20A M-150S-AV

Replace Motor ProtectorNOTE: The pump can remain on the tank during motor

protector replacement.

• Turn off the pump and disconnect from power.

• Remove the switch coverplate from the pump housing. (Figure 15)

FIGURE 15

• Remove switch bracket mounting screw and gently pull switch from switch cavity. (Figure 16)

FIGURE 16

• Remove the red wires from the terminals on the back of the switch.

• Remove the remaining wire on motor protector then remove the motor protector from switch cavity.

• Install new motor protector by reversing above pro-cedure.

NOTE: Make sure the O-ring is seated properly before tightening the switch coverplate.

Replace Switch Lever or Switch Lever Shaft O-Ring• Turn off the pump and disconnect from power.

• Remove the switch coverplate from the pump housing.

• Remove the screw connecting the switch cam to the coverplate.

• Remove the cam and switch lever.

• Replace the switch lever or switch lever shaft O-ring as needed.

• Reassemble by reversing the above procedure. Make sure the O-ring is seated properly before tightening the coverplate.

Replace Motor Shaft Seal• Turn the pump OFF and disconnect from power.

• Remove the gear coverplate, gears, and drive key as described in Gear Replacement instructions.

• Remove the motor from the pump housing.

• Remove the motor shaft seal by prying out with a small screwdriver. (Figure 17)

FIGURE 17

• Lubricate the gear shaft with WD-40® or a similar penetrating oil.

• Press a new motor shaft seal evenly in the pump hous-ing until seated. Lubricate the seal with a lightweight motor oil.

• Gently slide the shaft through the seal until the motor is flush against the pump housing.

• Tighten the motor to the pump housing. Check for proper installation by working a .0015 feeler gauge around the motor flange. The gauge should not fit between the flange and the housing.

• Install the gears and drive key as described in Gear Replacement instructions.

Replace MotorIn order to preserve the UL Listing or CSA Certification for pump safety, return the entire pump to the factory for motor repair or replacement. For products serviced outside the factory, the UL and CSA nameplates must be defaced to indicate the equipment may no longer meet the requirements for UL Listing or CSA Certification. This does not apply to products serviced outside the factory under the UL program for Rebuilt Motors for Use in Hazardous Locations and the CSA rebuild program.

Page 8: M-150S-AV Fuel Pump - Amazon S3

8 M-150S-AV 921422-20A

TROUBLESHOOTING

SYMPTOM PROBABLE CAUSE CORRECTIVE ACTION

A. MOTOR DOES NOT RUN

1. Fuse blown Inspect fuse in fuse holder on power cord. If blown, replace.

2. Switch defective Remove switch coverplate and inspect switch. Replace, if necessary.

3. Motor burned out Replace motor as described in the Repair Section.

4. Switch or electrical connections faulty

Inspect for damaged motor protector, defective wiring or switch, or im-proper electrical connections. Replace as needed and re-install.

5. Circuit breaker tripped Turn power off at source. Inspect the pump thoroughly; clean or repair. Reset circuit breaker by turning the power switch off then back on.

B. MOTOR RUNS, BUT DOES NOT PUMP

1. Suction pipe clogged, damaged, or missing

Remove pump from tank. Inspect suction pipe. Clean or replace, as necessary.

2. Gear coverplate or O-ring damaged Remove and inspect the coverplate and O-ring. Replace, as necessary. Refer to the Repair Section on Servicing O-rings.

3. Strainer clogged or defective Remove strainer coverplate. Remove and clean strainer. Install again.

4. Bypass poppet O-ring worn or missing

Inspect O-ring using instructions in the Repair Section. Replace, if necessary.

5. Bypass poppet O-ring dirty Remove poppet assembly and clean poppet and cavity.

6. Bypass poppet binding or damaged Using instructions in the Repair Section, remove the bypass poppet, spring, and O-ring. Clean cavity. Inspect and replace components, as necessary.

7. System air leak Tighten all pump fittings and connections. Inspect suction pipe for leaks or damage.

8. System air lock This can occur if external filter, meters, or an off-the-shelf automatic nozzle is used. To correct, remove the pipe plug in the top outlet port and fill the gear cavity with fuel. Use of a factory-supplied automatic nozzle is recommended.

9. Poor connections or low voltage Make sure electrical connections are secure. Also check battery voltage.

10. Fuel level low Fill tank.

11. Motor running backwards due to incorrect polarity

Connect red wire to positive (+) ungrounded side of battery. Gear with key should turn counterclockwise.

C. LOW FLOWRATE

1. Poor connections or low voltage Make sure electrical connections are secure. Also check battery voltage.

2. Strainer partially clogged Remove the strainer coverplate. Remove and clean the strainer. Install again.

3. Suction pipe clogged or damaged Remove pump from tank. Inspect suction pipe. Clean or replace, as necessary.

4. Fuel tank empty Fill tank.

5. Using off-the-shelf automatic nozzle Factory-supplied automatic nozzle is recommended.

6. System air leak Tighten all pump fittings and connections. Inspect suction pipe for leaks or damage. Replace, as necessary.

7. Bypass poppet spring weak Using instructions in the Repair Section, remove the bypass poppet and inspect spring. Replace, if necessary.

D. MOTOR STALLS WHEN OPERATING IN BYPAS MODE

1. Motor protector activated Turn off switch. Allow motor to cool, then turn on switch.

2. Gears locked Remove gear coverplate and inspect gears and drive key. Make sure gears turn freely with the key removed. Replace, if worn.

3. Wiring defective Use Wiring instructions in the Installation Section to ensure proper con-nections.

4. Bypass poppet binding or damaged Using instructions in the Repair Section, remove the bypass poppet, spring, and O-ring. Clean cavity. Inspect components and replace, as necessary.

5. Motor defective Replace motor as described in the Repair Section.

E. SWITCH FAILS TO OPERATE MOTOR

1. Switch or electrical connections faulty

Inspect for damaged motor protector, blown fuse, defective wiring or switch, or improper electrical connections. Replace as needed and re-install.

2. Motor burned out Replace motor as described in the Repair Section.

3. Motor protector activated Turn off switch. Allow motor to cool, then turn on switch.

F. RAPID OVERHEATING OF MOTOR

1. Duty cycle too long Pump operation should not exceed the standard duty cycle of 30 minutes ON and 30 minutes OFF. Allow the pump to cool for 30 minutes.

2. Strainer clogged Remove strainer coverplate. Remove and clean strainer. Install again.

3. Suction pipe clogged or damaged Remove pump from tank. Inspect suction pipe. Clean or replace, as necessary.

4. Gears worn Remove gear coverplate and inspect gears and drive key. Make sure gears turn freely with key removed. Replace, if necessary.

5. Fuel level low Fill tank.

6. Running too long in bypass mode Limit bypass operation to 10 minutes.

Page 9: M-150S-AV Fuel Pump - Amazon S3

9921422-20A M-150S-AV

SPECIFICATIONSApplication

For use with aviation gasoline (AVGAS 100LL) and kerosene grade (JET A).

Pump Housing Lightweight, corrosion-resistant, cast aluminum body, conve-nient union ring for easy installation.

Performance Pump Rate Up to 15 GPM (57 LPM) Duty Cycle 30 min. ON, 30 min. OFF

Operating Temperature -20° F to +125° F (-29° C to +52° C)

Operating Pressure 15 PSI

Electrical Specifications Input 12-volt DC Current Draw 18 amps Motor 1900 RPM, 1/5 hp (150 watts) Motor Approval UL Listed, CSA Certified Motor Protection 20 amp circuit breaker Cord 18 ft. of 12 gauge (5.5 m) Fuse 25 amp

Mechanical Connection Bung 2 inch NPT Inlet 1 inch NPT Outlet 3/4 inch NPT

Accessories None

Weight 16.6 lbs. (7.5 kg)

PARTS AND SERVICE

In order to preserve the UL Listing for the motor, do not attempt to service the motor. For products serviced outside the factory, the UL nameplate must be defaced to indicate that the equipment may no longer meet the requirements for UL Listing. This does not apply to products serviced outside the factory under the UL program for Rebuilt Motors for Use in Hazardous Locations.

For warranty consideration, parts, or other service in-formation, please contact your local distributor. If you need further assistance, contact the GPI Customer Service Department in Wichita, Kansas, during normal business hours.

A toll free number is provided for your convenience.1-800-835-0113

To obtain prompt, efficient service, always be prepared with the following information:

1. The model number of your pump.

2. The serial number or manufacturing date code of your pump.

3. Part descriptions and numbers.

Part information can be obtained from the Illustrated Parts List.

For warranty work, always be prepared with your original sales slip or other evidence of purchase date.

Please contact GPI before returning any parts. It may be possible to diagnose the trouble and identify needed parts in a telephone call. GPI can also inform you of any special requirements you will need to follow for shipping fuel dispensing equipment.

Do not return the pump or parts without authority from theCustomerServiceDepartment.Duetostrictgovernmentregula-tions,GPIcannotacceptpartsunless theyhavebeendrainedandcleaned.

CAUTION

SAVE THESE INSTRUCTIONS

Page 10: M-150S-AV Fuel Pump - Amazon S3

10 M-150S-AV 921422-20A

110500-02 25-amp Fuse Kit

110504-1 Fuel Pump Overhaul Kit - Includes 2 Gears, Drive Key & O-Rings

110524-1 Armature Assembly Kit (M-150S)

110525-1 Brush Card Assembly Kit - Includes Brush Holder Assembly

110526-1 Motor Housing Kit - Includes Motor Housing Assembly

110527-1 Battery Clamp Kit - Includes 2 Battery Clamps

110906-1 Wet Seal Kit - Includes O-Rings & Motor Shaft Seal

110907-1 Gear Kit - Includes 2 Gears & Drive Key

110908-1 Poppet Seal Kit - Includes Poppet O-Ring

110909-1 Bung Adapter Kit

110910-02 Switch Kit - Includes Switch

110913-2 Spare Key Kit - Includes Spare Drive Key

110927-04 Gear Coverplate Kit

111501-1 Adapter Kit

902006-31 Motor Protector Only

906001-4 Pre-Vent Vapor Control Cap (3 psi)

Item No. Part No. Description No. Req'd.2 904002-23 Sems Screw, 1/4-20 x 3/4 in. ..................................93 119000-1 Motor, 12-volt (UL) .................................................14 11002502 Seal, Motor Shaft ....................................................15 904002-17 Strain Relief Sealing Grip .......................................17 904001-42 Pipe Plug, 3/4 inch..................................................18 110010-1 Bypass Poppet .......................................................19 110131-2 Spring, Bypass Poppet ..........................................111 110265-02 Power Cord, 12 ga. x 18 ft. (5.5 m) ........................116 110026-1 Gear Coverplate O-Ring .........................................118 110024-1 Coverplate, Strainer................................................119 110026-4 Strainer Coverplate O-Ring ....................................120 110009-1 Inlet Strainer ...........................................................121 110195-02 Coverplate, Electrical .............................................122 110285-01 Electrical Coverplate Gasket ..................................123 110277-05 Switch Assembly.....................................................129 110026-6 Switch Coverplate O-Ring ......................................130 110276-01 Switch Coverplate Assembly ..................................131 110032-1 Gasket, Union Ring ...............................................132 110037-1 Bung Adapter ..........................................................138 904002-24 Sems Screw ...........................................................439 904002-22 Sems Screw ...........................................................440 904006-86 Tapping Screw ........................................................241 11030301 Nozzle Cover ..........................................................1

Items Not Shown

ILLUSTRATED PARTS LIST

39

18

19

20 2

30

23

40

41

5

2

34

7

8

9

29

21

16

38

31

11

22

32NOTE: Hose and Nozzle supplied by customer.

GPI®

Page 11: M-150S-AV Fuel Pump - Amazon S3
Page 12: M-150S-AV Fuel Pump - Amazon S3

02/14

LISTED MOTOR

Limited Warranty Policy

Great Plains Industries, Inc. 5252 E. 36th Street North, Wichita, KS USA 67220-3205, hereby provides a limited warranty against defects in material and workmanship on all products manufactured by Great Plains Industries, Inc. This product includes a 2 year warranty from date of purchase as evidenced by the original sales receipt. A 30 month warranty from product date of manufacture will apply in cases where the original sales receipt is not available. Reference product labeling for the warranty expiration date based on 30 months from date of manufacture. Manufacturer’s sole obligation under the foregoing warranties will be limited to either, at Manufacturer’s option, replacing or repairing defective Goods (subject to limitations hereinafter provided) or refunding the purchase price for such Goods theretofore paid by the Buyer, and Buyer’s exclusive remedy for breach of any such warranties will be enforce-ment of such obligations of Manufacturer. The warranty shall extend to the purchaser of this product and to any person to whom such product is transferred during the warranty period.This warranty shall not apply if:

A. the product has been altered or modified outside the warrantor’s duly appointed representative;B. the product has been subjected to neglect, misuse, abuse or damage or has been installed or operated other than in ac-

cordance with the manufacturer’s operating instructions.To make a claim against this warranty, contact the GPI Customer Service Department at 316-686-7361 or 800-835-0113. Or by mail at:

Great Plains Industries, Inc.5252 E. 36th St. North

Wichita, KS, USA 67220-3205GPI will step you through a product troubleshooting process to determine appropriate corrective actions.GREAT PLAINS INDUSTRIES, INC., EXCLUDES LIABILITY UNDER THIS WARRANTY FOR DIRECT, INDIRECT, INCIDENTAL AND CONSEQUENTIAL DAMAGES INCURRED IN THE USE OR LOSS OF USE OF THE PRODUCT WARRANTED HEREUNDER.The company herewith expressly disclaims any warranty of merchantability or fitness for any particular purpose other than for which it was designed.This warranty gives you specific rights and you may also have other rights which vary from U.S. state to U.S. state.Note: In compliance with MAGNUSON MOSS CONSUMER WARRANTY ACT – Part 702 (governs the resale availability of the war-ranty terms).

921422-20A

© 2014 Great Plains Industries, Inc. All Rights Reserved. Made in U.S.A. and The Proven Choice

are trademarks, and GPI is a registered trademark of Great Plains Industries, Inc.