lvp - gimaticusa.com · 2018-01-29 · 109 01/2015 lvp lvp 25 0500 0400 0300 0200 - 300* 70 sin...
TRANSCRIPT
www.gimatic.com108
01
/20
15
LVPLVP
Electric linear guides
Guide lineari elettriche
Electric linear guides
• Integrated linear motor.• Integrated encoder sensor.• Recirculating ball-bearing guide system.• 200mm, 300mm, 400mm and 500mm strokes.• T-nut mounting.• M12 standard electrical connection.• Compatible with several drives available on the market.• Optional magnetic homing sensors.• Compatible with LV electric linear actuators and ZV pneumatic
actuators.
Recirculating ball bearing guide• Structure in extruded aluminium designed to be lightweight
and dissipate heat.• Hardened steel bars inserted in the aluminium body.• Long life bearings.• Adjustable preloading for zero backlash adjustment.
Adjustment screws
T-nut grooves for fastening
Hardened steel bars
M12 connection
Recirculating ball bearing
Hardened steel bars
Recirculating ball bearing
Hardened pins
Electric linear guides
www.gimatic.com 109
01
/20
15
LVP
LVP 25 0500040003000200
- 300*70
SIN HALLABZ
Electric linear guides
LVP250200 LVP250300 LV250400 LV250500
Stroke 200 mm 300 mm 400 mm 500 mm
Mass of the parts integral with the slider 1700 g 2010 g 2300 g 2605 g
Mass of the parts integral with the stator 1030 g 1030 g 1030 g 1030 g
Total Mass (motor included) 2730 g 3040 g 3330 g 3635 g
Order codeLVP250200-
70LVP250200-
300LVP250300-
70LVP250300-
300LVP250400-
70LVP250400-
300LVP250500-
70LVP250500-
300
Linear motor ML2570X6 ML25300X6 ML2570X6 ML25300X6 ML2570X6 ML25300X6 ML2570X6 ML25300X6
BUS voltage 72 Vdc 325 Vdc 72 Vdc 325 Vdc 72 Vdc 325 Vdc 72 Vdc 325 Vdc
Peak force 105.4 N 131.6 N 105.4 N 131.6 N 105.4 N 131.6 N 105.4 N 131.6 N
(110°C)Peak current 5.2 A 2.1 A 5.2 A 2.1 A 5.2 A 2.1 A 5.2 A 2.1 A
Force constant 20.3 N/A 62.7 N/A 20.3 N/A 62.7 N/A 20.3 N/A 62.7 N/A 20.3 N/A 62.7 N/A
Continuous force 42.4 N 43.9 N 42.4 N 43.9 N 42.4 N 43.9 N 42.4 N 43.9 N
Continuous current (110* C) 2.05 A 0.7 A 2.05 A 0.7 A 2.05 A 0.7 A 2.05 A 0.7 A
Thermal resistance 1.35 °C/W 1.1 °C/W 1.35 °C/W 1.1 °C/W 1.35 °C/W 1.1 °C/W 1.35 °C/W 1.1 °C/W
Maximum speed 2 m/s
Temperature range 5 ÷ 80 °C
Environmental Degree IP67
Order code
Encoder sensor
Magnetic slider
Linear motor
LVP25 actuator
Motor size
Stroke
BUS voltage
Encoder sensor
Phase sensor
www.gimatic.com110
01
/20
15
LVP
ZX
Ix= 83475 mm4
Iz= 99807 mm4
max
Fx 1200 N
Fz 1200 N
Mx 60 Nm
My 11 Nm
Mz 60 Nm
Electric linear guides
Safety loadsExcessive loads can damage the unit, cause functioning troubles and endanger the safety of the operator. The load factor LF must be lower than 1.
Area moment of inertia for the extruded aluminum profile
www.gimatic.com 111
01
/20
15
LVP
C L52
90
C L210
B
71.5
CL 42
A
CL 14
36
CL 30
CL 42
15
29.5
54
32
71.5
53
11
6
32
54
CL 5.2
CL 7.4
3.4
5.4 6.5
M4
(4x)
Ø3
H8
(2
x)
7
3
MM
K
K
LVP250200 LVP250300 LVP250400 LVP250500
A 555 655 - 855
B 255 355 - 555
FIRST ANGLEPROJECTION
LP23-67MFM-058
Electric linear guides
Dimensions (mm)
T-nut groovesAll slots have the same size and T-nuts can be
used.
www.gimatic.com112
01
/20
15
LVP
90
100
110
120
130
140
0 20 40 60 80 100 120 140 160 180 200
0 kg
0.5 kg
1 kg
1.5 kg
2 kg
0
0.020
0.040
0.060
0.080
0.100
0.120
0.140
0.160
0.180
0 20 40 60 80 100 120 140 160 180 200
0 kg
0.5 kg
1 kg
1.5 kg
2 kg
0
0.020
0.040
0.060
0.080
0.100
0.120
0.140
0.160
0.180
0.200
0.220
0 20 40 60 80 100 120 140 160 180 200
A
C
B
D
90
100
110
120
130
140
0 30 60 90 120 150 180 210 240 270 300
A
C
B
D
LVP250200-70
LVP250300-70
LVP250200-300
LVP250300-300
(ML25300X6)
(ML25300X6)
(ML2570X6)
(ML2570X6)
Electric linear guides
Force Stroke
A 131.6 N 0 mm
B 131.6 N 200 mm
C 105.4 N 0 mm
D 105.4 N 200 mm
Force Stroke
A 131.6 N 0 mm
B 131.6 N 300 mm
C 105.4 N 0 mm
D 105.4 N 300 mm
LVP250200...The peak force of the actuator is constant during the whole stroke. The diagrams show the best single time of the actuator movement with different loads in vertical and horizonatal position. An appropriate delay time Toff should be added to allow for the system to cool, once the movement cycle has been checked.
Stroke [mm]
Peak
forc
e [N
]
LVP250300...The peak force of the actuator is constant during the whole stroke. The diagrams show the best single time of the actuator movement with different loads in vertical and horizonatal position. An appropriate delay time Toff should be added to allow for the system to cool, once the movement cycle has been checked.
Stroke [mm]
Peak
forc
e [N
]
www.gimatic.com 113
01
/20
15
LVP
90
100
110
120
130
140
0 40 80 120 160 200 240 280 320 360 400
A
C
B
D
90
100
110
120
130
140
0 50 100 150 200 250 300 350 400 450 500
A
C
B
D
LVP250400-70
LVP250500-70
LVP250400-300
LVP250500-300
(ML25300X6)
(ML25300X6)
(ML2570X6)
(ML2570X6)
Electric linear guides
ForzaForce
CorsaStroke
A 131.6 N 0 mm
B 131.6 N 400 mm
C 105.4 N 0 mm
D 105.4 N 400 mm
ForzaForce
CorsaStroke
A 131.6 N 0 mm
B 131.6 N 500 mm
C 105.4 N 0 mm
D 105.4 N 500 mm
LVP250400...The peak force of the actuator is constant during the whole stroke. The diagrams show the best single time of the actuator movement with different loads in vertical and horizonatal position. An appropriate delay time Toff should be added to allow for the system to cool, once the movement cycle has been checked.
Stroke [mm]
Peak
forc
e [N
]
LVP250500...The peak force of the actuator is constant during the whole stroke. The diagrams show the best single time of the actuator movement with different loads in vertical and horizonatal position. An appropriate delay time Toff should be added to allow for the system to cool, once the movement cycle has been checked.
Stroke [mm]
Peak
forc
e [N
]
www.gimatic.com114
01
/20
15
LVP
38
14
28
30
52
62
3M4 (4x)
5.5
Ø3 (2x)
7
= =
= =
=
=
==
=
=
= =
LVP250200
LVP250200
LV25-KIT-01
LV25-KIT-01
LV25050
LV25050
LV25050
Electric linear guides
LV25-KIT-01
Mounting interface plate• Weight: 57g.
Application examples
www.gimatic.com 115
01
/20
15
LVP
30
42
21
48
12
621 Ø3 (2x)
M4 (4x)
6.5
42
5
3
6
6.5
14
52
60
41
22
= =
= =
= =
= =
= =
LVP250200
LV25-KIT-07
LV25050
Electric linear guides
Application example
LV25-KIT-07
Mounting interface plate• Weight: 90g.
www.gimatic.com116
01
/20
15
LVP
OUT
OUT
PNP
NPN
Magneto-resistive
SN...
SS...
Electric linear guides
SN4N225-G PNP 2.5m Cable
SN4M225-G NPN 2.5m Cable
SN3N203-G PNP Snap M8 plug connector
SN3M203-G NPN Snap M8 plug connector
SS4N225-G PNP 2.5m Cable
SS4M225-G NPN 2.5m Cable
SS3N203-G PNP Snap M8 plug connector
SS3M203-G NPN Snap M8 plug connector
SensorsExtrastroke and zero position detection is made by magnetic proximity sensors (optional) fixed on the profile of the slide with special brackets.
High-sensitivity sensors (HS suffix) can be used, if necessary.
Use sensors:
Magnet
Sensor Sensor bracket
They are all provided with a 3-wire flat cable and a LED.
www.gimatic.com 117
01
/20
15
LVP
Electric linear guides
CFGM800325P CFGM1200525P CFGM1200825P0° axial
CFGM890325P90° angular
Gripper
CFGM1290525P
Motor
CFGM1290825P
EncoderApplication
FemaleContact type
3 5 8Number of contacts
2.5 mStandard length
Bare CopperMaterial
32 x 0.10 mm 42 x 0.10 mm 32 x 0.10 mmStranding
0.25 mm2 / 24 0.34 mm2 / 22 0.25 mm2 / 24Section - AWG
- < 58.16 Ω/km < 76.33 Ω/kmElectrical resistance
Ø 1.25 mm Ø 1.30 mm Ø 1.15 mmConductor diameter
TPO PPConductor compound
- Fully shieldedShield
- BraidShield type
Ø 4.1 mm ±0.25 mm Ø 6.3 mm ±0.2 mmCable diameter
PURCable material
RAL 9005Cable color
Oil, Hydraulic fluide and UV resistant, Silicone, Pb, Cd, Hg, FCKW and Halogen freeFeatures
41 mm 63 mmMin. bending radius
EN 50363-10-2, IEC 60754-1, UL/CSA style 21576
2002/95/CE, EN 50363-10-2, IEC 60344Reference standards
1 Brown3 Blue4 Black
1 Brown2 White3 Blue4 Black5 Gray
1 White2 Brown3 Green4 Yellow5 Gray6 Pink7 Blue8 Red
Color layout
1
4
3
4
3
52
1
2 3
4
5
86
7
1
CFGM800325P CFGM1200525P CFGM1200825P
CFGM890325P CFGM1290525P CFGM1290825P
ConnectorsMotor, sensors and grippers connection can be done thanks to the axial and 90° angular standard connectors with special flexible cable for moving applications.
www.gimatic.com118
01
/20
15
LVP
Electric linear guides
LubricationPeriodically check the steel bars and lubricate when dry. The suitable grease is available in 90 grams tubes. Ordering code: GPL500-90.
Remove the protection metal plate.
Lubricate the steel bars.
Move the carrier to distribute the lubricant in the ball bearings.
Pay attention not to drive the carrier out of the guide.