lrd series - warestarwarestar.com/wp-content/uploads/2017/06/lumenoptix...westroads mall omaha, ne...

16
LRD SERIES Specification LED Retrofit Downlight

Upload: others

Post on 01-Sep-2020

1 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: LRD SERIES - Warestarwarestar.com/wp-content/uploads/2017/06/LumenOptix...Westroads Mall Omaha, NE Existing: 175W and 150W Metal Halides Upgraded to: LumenOptix 2000 and 4000 lumen

LRD SERIESSpecification LED Retrofit Downlight

Page 2: LRD SERIES - Warestarwarestar.com/wp-content/uploads/2017/06/LumenOptix...Westroads Mall Omaha, NE Existing: 175W and 150W Metal Halides Upgraded to: LumenOptix 2000 and 4000 lumen
Page 3: LRD SERIES - Warestarwarestar.com/wp-content/uploads/2017/06/LumenOptix...Westroads Mall Omaha, NE Existing: 175W and 150W Metal Halides Upgraded to: LumenOptix 2000 and 4000 lumen

3

More Than Just A Retrofit Downlight...

For over a decade, LumenOptix solutions have been the standard for easy to install,

specification-grade luminaires whenever a lighting upgrade takes place within an

existing facility.

LumenOptix has applied that methodology to the LRD series, a specification-grade

LED downlight retrofit. Our patent pending, tool-less installation ensures no alterations

to the existing infrastructure and installs in minutes, all from beneath the ceiling. With

multiple size options, lumen packages, optical distributions, and the ability to accom-

modate existing dimming systems, the LRD is the perfect solution for any facility look-

ing to upgrade and improve the integrity of the original lighting design.

LED Module:Open architecture, allows

specification of module to match desired lighting

criteria.

LED Driver:Open architecture, allows compatibility with existing control systems.

Heat Sink: LRD is thermally engineered to ensure optimal fixture life.

Patent Pending Installation Mechanism:Allows facilities to upgrade without any alterations to the existing ceiling surface.

Specification-Grade OpticsEnsures that the integrity of the original lighting design is main-tained or improved.

Page 4: LRD SERIES - Warestarwarestar.com/wp-content/uploads/2017/06/LumenOptix...Westroads Mall Omaha, NE Existing: 175W and 150W Metal Halides Upgraded to: LumenOptix 2000 and 4000 lumen

Installation Process

The patent pending LumenOptix LRD 5-step, tool-less installation is quick and easy. Upgrade any existing commercial, institutional or retail downlight, no matter the make or model to LED without any alterations to the existing ceiling.

4

1 Remove and Discard Simply remove and discard the existing reflector and lamp.

2 Tether and Connect Tether the LRD to the existing frame to make wiring as easy as possible. Then connect the existing power to the LRD (no need to pull additional wiring).

3 Slide and Position Slide the housing into the existing rough-in kit and position the LRD driver into the appropriate location.

4 Move and Tighten Move the thumb screws from the up position to the down and tighten them against the existing rough-in kit, creating a secure, leak-free fit.

5 Snap In and Complete Snap in the LRD reflector and the installation is complete.

1 2 3 4 5

Page 5: LRD SERIES - Warestarwarestar.com/wp-content/uploads/2017/06/LumenOptix...Westroads Mall Omaha, NE Existing: 175W and 150W Metal Halides Upgraded to: LumenOptix 2000 and 4000 lumen

5

Specification-Grade OpticsThe LumenOptix LRD’s performance is defined by its specification-grade optics. Each reflector is designed around the module, creating various beam distributions while minimizing glare. As a result, the integrity of the original lighting design is maintained or improved. In addition, LumenOptix offers various finishes (specular, semi-specular, and diffused) and multiple color options to ensure the correct specification for every application, every time. The below images illustrate our 8” semi-specular optical capa-bilities:

Diameter

Height25°

Diameter

40°Height

Diameter

80°

Height

8” Semi-Specular Narrow Beam

8” Semi-SpecularMedium Beam

8” Semi-Specular Wide Beam

Page 6: LRD SERIES - Warestarwarestar.com/wp-content/uploads/2017/06/LumenOptix...Westroads Mall Omaha, NE Existing: 175W and 150W Metal Halides Upgraded to: LumenOptix 2000 and 4000 lumen

Aperture Sizes The LRD product family can upgrade existing downlights to LED from 6.5” to 15” in commercial and institutional facilities. We offer 6”, 7”, 8” and 10“ standard size housings with various size extended trim rings (goof rings), to ensure a perfect fit every time. The chart below outlines what LRD housing to specify based on the size of the existing downlight.

Existing Cut-Out Dimension LRD Size Conversion6.5” - 6.97” LRD 6”

6.98” - 7.26” LRD 6” With Goof Ring7.27” - 7.86” LRD 7”7.87”- 8.42” LRD 8”8.43” - 9.85” LRD 8” With Goof Ring

9.86” - 10.34” LRD 10”10.35” - 15” LRD 10” With Goof Ring

6

6” Housing 7” Housing 8” Housing 10” Housing

Page 7: LRD SERIES - Warestarwarestar.com/wp-content/uploads/2017/06/LumenOptix...Westroads Mall Omaha, NE Existing: 175W and 150W Metal Halides Upgraded to: LumenOptix 2000 and 4000 lumen

Lumen Packages

LumenOptix offers the widest range of lumen packages within a specification- grade downlight retrofit ranging from 1,000 - 16,000 lumens. The chart below outlines various existing light source conversions to LRD.

7

LRD Lumen Package Conversion Chart

Existing Lamp TypeExisting System

Wattage

Initial Lumens

Average Efficiency

In a Downlight

LLD at 1 Year

Delivered Lumens

LRD Lumen Package

Equivalent

LRD Wattage

Draw

Wattage Saved

% of Energy Saved

Vertical CFL 26W 1 lamp 30 1,800 65% 80% 936 1,000 15 15 50%

Horizontal CFL 32W 1 lamp 36 2,400 55% 80% 1,056 1,000 15 21 58%

100W Halogen Quartz 100 1,400 90% 90% 1,134 1,000 15 85 85%

Vertical CFL 32W 1 lamp 36 2,400 65% 80% 1,248 1,000 15 21 58%

Horizontal CFL 42W 1 lamp 46 3,200 55% 80% 1,408 1,500 22 24 52%

Horizontal CFL 26W 2 lamp 56 3,420 55% 80% 1,505 1,500 22 34 61%

Vertical CFL 42W 1 lamp 46 3,200 65% 80% 1,664 1,500 22 24 52%

Horizontal CFL 32W 2 lamp 66 4,800 55% 80% 2,112 2,000 28 38 58%

50W Ceramic Metal Halide 65 4,100 65% 85% 2,265 2,000 28 37 57%

70W Probe Start Metal Halide 90 5,700 65% 70% 2,594 3,000 43 47 52%

Horizontal CFL 42W 2 lamp 88 6,400 55% 80% 2,816 3,000 43 45 51%

250W Halogen Quartz 250 3,600 90% 90% 2,916 3,000 43 207 83%

70W Ceramic Metal Halide 85 6,200 65% 85% 3,426 4,000 57 28 33%

100W Probe Start Metal Halide 130 8,200 65% 70% 3,731 4,000 57 73 56%

150W Probe Start Metal Halide 185 11,000 65% 70% 5,005 6,000 85 100 54%

100W Ceramic Metal Halide 125 9,500 65% 85% 5,249 6,000 85 40 32%

150W Ceramic Metal Halide 175 14,000 65% 85% 7,735 8,000 114 61 35%

175W Pulse Start Metal Halide 205 16,000 65% 80% 8,320 8,000 114 91 44%

250W Probe Start Metal Halide 295 20,000 60% 70% 8,400 8,000 114 181 61%

500W Halogen Quartz 500 11,000 85% 90% 8,415 8,000 114 386 77%

250W Pulse Start Metal Halide 280 23,000 65% 80% 11,960 12,000 135 145 53%

320W Pulse Start Metal Halide 350 29,500 65% 80% 15,340 16,000 180 170 48%

Page 8: LRD SERIES - Warestarwarestar.com/wp-content/uploads/2017/06/LumenOptix...Westroads Mall Omaha, NE Existing: 175W and 150W Metal Halides Upgraded to: LumenOptix 2000 and 4000 lumen

8

Page 9: LRD SERIES - Warestarwarestar.com/wp-content/uploads/2017/06/LumenOptix...Westroads Mall Omaha, NE Existing: 175W and 150W Metal Halides Upgraded to: LumenOptix 2000 and 4000 lumen

9

Control Compatibility Many LED drivers are designed to be compatible with 0-10V control systems. However, when you encounter an older phase cut dimming system, not every LED luminaire will work. Some LEDs have a delay, flicker, or simply don’t work at all.

With LumenOptix’ extensive dimming knowledge and open architecture on modules and drivers, we are able to select the compatible module and driver for the current control system. This is crucial in market segments such as auditoriums, churches and theaters which commonly utilize phase dimming, 0-10V or Lutron® control systems.

By utilizing the LumenOptix LRD, the majority of facilities can upgrade to LED without changing their control system and still have smooth, even dimming.

Page 10: LRD SERIES - Warestarwarestar.com/wp-content/uploads/2017/06/LumenOptix...Westroads Mall Omaha, NE Existing: 175W and 150W Metal Halides Upgraded to: LumenOptix 2000 and 4000 lumen

10

LRD1 Philips DLM Fortimo or DLM Flex

1000, 2000, 3000

80 CRI

3000K, 3500K, 4000K

SERIES

NOMINAL LUMENS

CRI

COLOR TEMP.

LRD2 GE DLM Infusion Twist and Lock Replaceable

1000, 1500, 2000, 3000, 4000

92 CRI

2700K, 3000K, 3500K, 4000K

LRD3 CREE LMH2

1250, 2000, 3000, 4000, 6000, 8000

90 CRI

2700K, 3000K, 3500K, 4000K, 2700-1800K Sunset Dimming

6”, 7”, 8”, 10”

Narrow, Medium, Wide, Wall Wash (6” Only)

Semi-Specular, Diffused, Specular, Painted, All in a Variety of Colors

Non-Dimming, 0-10V, Lutron® 3-Wire, Lutron® EcoSystem, 2-Wire Leading Edge, 2-Wire Trailing Edge

SIZE

BEAM SPREAD

REFLECTORFINISH

DIMMING*

* Dimming options available with most lumen configurations. Consult specification sheet for details.

LRD Product Platform

Page 11: LRD SERIES - Warestarwarestar.com/wp-content/uploads/2017/06/LumenOptix...Westroads Mall Omaha, NE Existing: 175W and 150W Metal Halides Upgraded to: LumenOptix 2000 and 4000 lumen

11

LRD CASE STUDIESSpecification LED Retrofit Downlight

Page 12: LRD SERIES - Warestarwarestar.com/wp-content/uploads/2017/06/LumenOptix...Westroads Mall Omaha, NE Existing: 175W and 150W Metal Halides Upgraded to: LumenOptix 2000 and 4000 lumen

Featured Case Studies

BEFORE

AFTER

Garnet Valley Middle SchoolGlen Mills, PA

12

Existing: 250W Halogen Quartz

Upgraded to: LumenOptix 2000 lumen LRD

Key Project Drivers:

• No alteration to existing hard ceiling during upgrade• LRD compatible with existing phase dimming system• Reduced energy costs by 88%• Increased light output by 25%

Grand Canyon UniversityPhoenix, AZ

Existing: Incandescent Downlights

Upgraded to: LumenOptix 1000, 2000 and 3000 lumen LRD

Key Project Drivers:

• No alteration to existing hard ceiling during upgrade

• Reduced glare, providing a better learning environment

• Increased light output by more than 50%• Significant maintenance savings

Page 13: LRD SERIES - Warestarwarestar.com/wp-content/uploads/2017/06/LumenOptix...Westroads Mall Omaha, NE Existing: 175W and 150W Metal Halides Upgraded to: LumenOptix 2000 and 4000 lumen

Featured Case Studies

13

Thomas Jefferson University and HospitalPhiladelphia, PA

Existing: 2 lamp, 26W CFLs

Upgraded to: LumenOptix 2000 lumen LRD

Key Project Drivers:

• No alteration to existing hard ceiling during upgrade

• LRD compatible with existing Lutron® control system

• Improved color rendering• Increased light output by over 50%

BEFORE

AFTER

Arkansas Children’s HospitalLittle Rock, AR

Existing: 100W Mercury Vapor Downlights

Upgraded to: LumenOptix 2000 lumen LRD

Key Project Drivers:

• No alteration to existing hard ceiling during upgrade• LRD is damp location listing making it perfect for soffit

applications• Significantly improved color quality• Improved light output by over 50%

Before

After

BEFORE AFTER

Page 14: LRD SERIES - Warestarwarestar.com/wp-content/uploads/2017/06/LumenOptix...Westroads Mall Omaha, NE Existing: 175W and 150W Metal Halides Upgraded to: LumenOptix 2000 and 4000 lumen

Featured Case Studies

14

Don Hewlet Chevrolet DealershipAustin, TX

Existing: 175W Metal Halide

Upgraded to: LumenOptix 4000 lumen LRD

Key Project Drivers:

• No alteration to existing hard ceiling during upgrade• Improvement in color quality due to CRI of 90 and R9 value of 91• Proper cutoff angles provide even distribution and less surface glare• Significant energy savings

General Growth PropertiesWestroads MallOmaha, NEExisting: 175W and 150W Metal Halides

Upgraded to: LumenOptix 2000 and 4000 lumen LRD

Key Project Drivers:

• No alteration to existing hard ceiling during upgrade• 90 CRI and 92 R9 value of LRD was perfect for retail

applications• Reduced energy consumption by 75%• Increased light output by 25%

Page 15: LRD SERIES - Warestarwarestar.com/wp-content/uploads/2017/06/LumenOptix...Westroads Mall Omaha, NE Existing: 175W and 150W Metal Halides Upgraded to: LumenOptix 2000 and 4000 lumen

Featured Case Studies

15

Bon Secours Wellness ArenaGreenville, SC

Existing: CFL and Metal Halide Fixtures

Upgraded to: LumenOptix 1000 and 3000 lumen LRD

Key Project Drivers:

• Update appearance and efficiency• No disturbance to existing ceilings• 80% energy savings• Virtually eliminated maintenance

Amtrak Train StationsNew Carrollton, MD

BEFORE AFTER

Existing: 100W - 400W Mercury Vapors

Upgraded to: LumenOptix 4000 lumen LRDs and 2000 lumen Cylinders

Key Project Drivers:

• No alteration to existing hard ceiling during upgrade• Saved $126,000 in annual energy costs• Improved color rendering• Increased light output by over 50%