Joint stock company «ABS ZEiM Automation» is one of the leaders of of electric engineering in Russia. One of the company fields of activity is turnkey development of industrial processes automated control systems, industrial automation equipment.

«ABS ZEiM Automation» is one of the key elements of the «ABS Electro» international holding that has united companies in the Russian Federation. For more than 55 years «ABS Electro» provides EPC-services to electric power engineering, oil and gas, metallurgical, mining and other core-forming industries.

Our company started its history in 1958 with manufacturing of first Russian electric actuators. This line of activity is still one of the most important and we are holding leading positions in it.

«ABS ZEiM Automation» supplies:• electric actuators for pipeline fitting;• industrial controllers;• industrial processes control devices;• industrial processes measurement instruments and

automation means;• low-voltage switchgears;• power ducts and bus ducts.

«ABS ZEiM Automation» produces the following types of low voltage switchgears:• synchronous and asynchronous electric motors control

switchgears;• input switchgears (including those equipped with

Automatic Transfer Switches designed to operate currents up to 4000 A);

• distribution switchgears with cell design equipped with pull-breakers that also can be applied at electric power generating facilities and gas pumping stations;

• electric power distribution and electric actuators control switchgears (including those equipped with pull-breakers) for electric power plants and sub-stations;

• AC switchgears for sub-stations;• control, protection, signaling and automation

switchgears;• smart switchgears employing microprocessor-based

devices for operation within an industrial process automated control system.

Advantages and features of «ABS ZEiM Automation» switchgears:• wide range of produced switchgears;• design and manufacturing of switchgears of any

complexity in accordance with the customer’s requirements;

• implementation of original automation equipment (PBR-A reversing starters, PBR-I intelligent starters, BRU manual control units, FC, DUP-M units, etc.) and equipment from the leading Russian and foreign companies;

• developed distributors network;• capability of carrying out complex supplies of industrial

processes automated control equipment systems;• competitive prices.

Quality management system adopted by our company complies with the ISO 9001:2000 requirements which is confirmed by the TÜV Hessen CERT and EUROCART certificates.

Page 3: Low voltage switchgears

3

LOW VOLTAGE SWITCHGEARS

www.abs-zeim.ru

333

KSATO series industrial facilities complex automation system low-voltage switchgears designed to operate currents up to 4000 A – UVRUThis type of low-voltage switchgears is designed for input and distribution of electric power and for electric motors control. UVRU switchgears are assembled in metal

cabinets (panels) equipped with a chassis for electric equipment. Here is a description of UVRU series products nomenclature:

Note: cabinets (boxes, panels, terminals) dimensions can be changed on demand. Customized switchgears manufactured on the basis of a technical inquiry from a customer are also available.

Page 4: Low voltage switchgears

LOW VOLTAGE SWITCHGEARS

www.abs-zeim.ru

44

Main technical characteristics

Power, KW Block type index Nominal current, AThermal release adjustment

range

0,12 17 0,5 0,4-0,63

0,18 18 0,63 0,4-0,63

0,25 19 0,8 0,63-1

0,37 20 1 0,63-1

0,55 22 1,6 1-1,6

0,75 23 2 1,6-2,5

1,1 24 2,5 2,5-4

1,5 25 3,2 2,5-4

2,2 27 5 4,0-6,3

3 28 6,3 6-10

4 29 8 6-10

5,5 30 10 9-14

7,5 32 16 13-18

11 33 20 20-25

15 34 25 24-32

18,5 35 32 25-40

22 36 40 40-63

30 37 50 40-63

37 38 63 56-80

45 39 80 60-100

55 40 100 90-150

75 41 125 90-150

90 42 160 132-220

110 43 200 132-220

132 44 250 160-400

160 45 320 160-400

250 46 400 252-630

300 48 600 252-630

400 50 800 320-800

630 52 1000 400-1000

800 54 1250 500-1250

1000 56 1600 640-1600

1200 58 2000 800-2000

1600 60 2500 1000-2500

2000 62 3200 1280-3200

2500 64 4000 1600-4000

Rated current Table 1

Page 5: Low voltage switchgears

5

LOW VOLTAGE SWITCHGEARS

www.abs-zeim.ru

5

Power circuit nominal voltage Table 2

Third symbol in type index

0 4 7 8 9 B V G D Е

Unоm, В, connection No circuit~220 50 Hz

~380 50 Hz

~440 50 Hz

~415 50 Hz

~220 60 Hz

~380 60 Hz

~440 60 Hz

-48 -24

Номинальное напряжение цепей управления Table 3

Fourth symbol in type index

0 4 5 6 7 8 9 R S Т D Е

Unom, В,

connectionNo circuit

~220 50 Hz

~230 50 Hz

~240 50 Hz

~380 50 Hz

~400 50 Hz

~415 50 Hz

~220 60 Hz

~380 60 Hz

~440 60 Hz

-48 -24

Operation mode: continuous. Confirmed operating life – not less than 25 years (replacement of units or wires is possible).

Page 6: Low voltage switchgears

LOW VOLTAGE SWITCHGEARS

www.abs-zeim.ru

66

KSATO series switchgears (RTZO-88 type)These switchgears are designed for input and distribution of electric power and electric drives control in circuits with a solidly grounded neutral operating up to 1000 V, for control, signaling and equipment protection. Output lines are equipped with short-circuit protection devices designed for a nominal current load of up to 630 A and total supply current of up to 4000 A.

Switchgears are classified by the following criteria:- construction;- installation location;- transportability;- protection class;- screening;- components mounting type (e.g. fixed or dismountable);- operators protection;- internal partitioning type;- units electric interconnection.

KSATO series switchgears can use either solidly fixed or dismountable units (retractable or plug-in) which house power handling and control equipment. That is achieved by application of the Prisma Plus design principle: all the equipment is located on dismountable circuit boards that are installed on vertical mounting rails by means of clamps. Maintenance or upgrade can be carried out without power supply disconnection that allows uninterrupted operation in any conditions.

B X – XXX – XX – XX XX – XXX

Climatic version (UHL; T) and allocation category (2; 3) under GOST 15150-69 and GOST 15543.1-89

Power line and control line voltage

Current used by blocks

Components manufacturer:SE –Schneider Electric;Si – Siemens;Mo – Moeller;GE – General Electric;Lo – Lovato;AB – ABB;RU – Russian manufacturers.

Circuit No:0 – 499 – typical circuits500 – 999 – custom circuits

Switchgear purpose:A – automation;V – power input;P – connection;S – section;U – electric drive control.

Product type: B – block

Page 7: Low voltage switchgears

7

LOW VOLTAGE SWITCHGEARS

www.abs-zeim.ru

7

A

B

C

Blocks are divided in the following categories according to the connection type:A – retractable. A block is connected to output cables and to switchgear power bus by means of connectors;B – plug-in. A block is connected to switchgear power bus with connectors and to output cables with a dismountable plug-socket connection with a socket installed on a block;C – fixed. A block is connected to switchgear power bus and to output cables by terminal clamps.

Switchgears employing retractable or plug-in modules have a number of advantages:- easy and safe to upgrade, add or replace blocks;- easy to assemble. Dismountable circuit boards are easy to install from the front side of a cabinet using clamp connection that allows to avoid any intermediary connections and thus to provide quality and reliability of electrical contacts.- optimization of equipment allocation. Dismountable circuit boards height is pretty much suitable for installation of three-pole and four-pole equipment. Control wires are located inside functional blocks which allows to optimize space utilization in the process of equipment installation.

Parameter Value

Protection class under GOST 14254

IP20 - open switchgearIP31 - enclosed cabinet switchgearIP54 - protected cabinet switchgear

IP66 - special purpose protected cabinet switchgear

Main collector bus short circuit surge current, KA 10; 25; 50

Main collector bus nominal current, A 250; 400; 630; 1250; 1600; 3200; 2500; 4000

Control circuits nominal voltage 220 V, 50 Hz, phase-zero, 24 V DC. 380 V on demand

Major parameters of switchgears Table 4

Page 8: Low voltage switchgears

LOW VOLTAGE SWITCHGEARS

www.abs-zeim.ru

88

Nomenclature of power units for fitting electric drives, actuator electric motors and power distribution blocks Table 5

Purpose Block type (circuit No)Current range, A

FeaturesCorresponds

to

Auxiliary actuators motor power units

Actuator motor control BU-001-SE 0,1 - 150 -BM5130 analog

Control of an auxiliary actuator electric motor operated by a control panel

BU-003-SE 0,1 - 25 -BOE5103V

analog

Reversible motor control BU-004-SE 0,1 - 150 -BMR5340

analog

Control blocks for shutoff or control fitting electric motors operated by a control board or by a selective control system with a central control device

Reversible motor control (with fitting closing completion option using a current relay)

BU-005-SE 0,1 - 15 With a current and intermediary relaysBOE5401V

analog

Reversible motor control BU-007-SE 0,1 - 25 With an additional intermediary relayBOE5403V

analog

Reversible motor control (with fitting closing completion option using a current relay)

BU-009-SE 0,1 - 15 With a current relayBOE5405V

analog

Reversible motor control (with fitting closing completion option using a current relay)

BU-011-SE 0,1 - 25 Without current relayBOE5405V

analog

Reversible motor control BU-013-SE 0,1 - 25 With an additional intermediary relayBOE5406V

analog

Control blocks for shutoff or control fitting electric motors operated using a control board or by a selective control system with a central control device and a soft starter

Actuator motor control BU-101-SE 2,5 - 11 Three-phase power supply of a soft starter -

Reversible motor control BU-103-SE 44 - 85Automatic control allowing rotation direction change without slowing down, soft starter

-

Reversible motor control BU-105-SE 44 - 85Automatic control with or without slowing

down option, without contactor, soft starter controlled using a three-wire connection

-

Reversible motor control BU-107-SE 6 - 32Automatic control with rotation direction

change option without slowing down (equipped with a soft starter)

-

Actuator motor control BU-109-SE 6 - 32Automatic control with or without slowing down, without contactor (equipped with a soft starter), three-wire control connection

-

Actuator motor control BU-111-SE 0,1 - 150 Star-delta motor control scheme -

Actuator motor control BU-113-SE 17 - 140 Control using an ATS48 device -

Power units for control and shutoff pipeline fitting electric drives using remote control scheme

Three-phase electric drive control using an FC three-position thyristor amplifier

BU-200-RU 0,4-4 Electric motor start, reverseBOE5415V

analog

Three-phase electric drive control by a PBR-3A contactless starter

BU-201-RU 0,4-3Synchronous and asynchronous electric motor start and reverse, asynchronous

motor protection

BOE5413V analog

Single-phase electric drive control by a PBR-2M contactless starter

BU-202-RU 0,4-10BOE5414V

analog

Three-phase electric motor drive control by a contactless smart starter PBR-3I

BU-210-RUBU-212-RUBU-213-RUBU-214-RUBU-215-RU

0,4-16

Analog control optionWith RS-485 network interface and motor

protection from overheatingWith RS-485 network interface

With motor protection from overheating

-

Single-phase electric drive control by a contactless smart starter PBR-2I

BU-234-RUBU-236-RUBU-237-RUBU-238-RUBU-239-ru

0,09-10

Analog control optionWith RS-485 network interface and motor

protection from overheatingWith RS-485 network interface

With motor protection from overheating

-

Three-phase electric drive control by a PBR-3I contactless smart starter with a BU-30 amplifier used for control of mechanisms equipped with

rheostat or inductive position transducers

BU-270-RUBU-271-RUBU-272-RUBU-273-RUBU-274-RU

0,4-16

With motor protection from overheatingWith RS-485 network interface

With analog control optionWith RS-485 network interface and motor

protection from overheating

-

Page 9: Low voltage switchgears

9

LOW VOLTAGE SWITCHGEARS

www.abs-zeim.ru

9

Single-phase electric drive control by a PBR-2I contactless smart starter and a BU-30 amplifier used for control of mechanisms equipped with

rheostat or inductive position transducers

BU-275-RUBU-276-RUBU-277-RUBU-278-RUBU-279-RU

0,09-10

With motor protection from overheatingWith RS-485 network interface

With analog control optionWith RS-485 network interface and motor

protection from overheating

-

Three-phase electric drives control by a KIM1 actuators controller

BU-267-RUBU-268-RUBU-269-RU

0,4-1,2With analog control option

With discrete control optionWith network control option

-

Three-phase electric drive control by a PBR-3A contactless starter with a BTZ-3 thermal protection

blockBU-280-RU 0,4-3 With motor protection from overheating -

Three-phase electric drive control by a PBR-3A contactless starter equipped with a BU-30 block for control of mechanisms equipped with rheostat or

inductive position transducers

BU-281-RU 0,4-3Synchronous and asynchronous electric motor start and reverse, asynchronous

motor protection-

Three-phase electric drive control by a PBR-3IM contactless starter

BU-282-RU 0,4-16 - -

Distribution blocks

With automatic switches (56 modules) BR-001-SE Up to 100 AC power distribution blockBOE8504V

analog

With one automatic switch BR-003-SE Up to 630Distribution block (switch with an

independent release)-

With one automatic switch BR-005-SE Up to 630Distribution block (switch with an independent

reducing gear and release)-

Input blocks

With one knife switchBV-001-SE Up to 160 Input block with a voltmeter and a switch

BOE8102Vanalog

BV-003-SE Up to 630 Input block -

Automatic switch with additional terminals BV-005-SEFrom 630 to

4000Input block -

With 2 automatic switches BV-007-SE Up to 630 - -

With 2 knife switches BV-009-SE Up to 630 Input block -

With 2 contactors BV-011-SE Up to 630 Input block -

Terminal block BV-012-SE Up to 250 Input block -

Various purpose blocks

Manual control blocks

BA-001-RU -Shutoff fitting electric drive control block used

together with BOE54XXVBOE9502V

analog

BA-002-RU - For input block -

BA-003-RU - Electric motor control equipment blockBU9511

block

BA-004-RU - Metering block -

BA-005-RU - Electric motor control equipment blockBU9512 analog

BA-007-RU - Electric motor control equipment blockBU9513 analog

BA-009-RU - Electric motor control equipment blockBU9514 analog

BA-011-RU - Distribution block -

Relay block

БА-025-RU - Automatic transfer switch -

БА-027-RU - Input -

БА-029-RU - Sectioning -

Purpose Block type (circuit No)Current range, A

FeaturesCorresponds

to

Selection of blocks and ordering of UVRU-SH series cabinets is carried out using a data sheet filled in on the basis of KSATO series switchgears specifications.

Page 10: Low voltage switchgears

LOW VOLTAGE SWITCHGEARS

www.abs-zeim.ru

1010

Data

she

et

Pane

l typ

eKS

ATO

serie

s ca

bine

t

Met

al w

ork

type

UVRU

-SH-

11-4

074-

SNOP

UHL

4UV

RU-S

H-31

-307

4-SN

OP U

HL4

UVRU

-SH-

31-3

074-

SNOP

UHL

4UV

RU-S

H-31

-307

4-SN

OP U

HL4

Cabi

net N

o1

23

4

Type

blo

ck

Bloc

ks m

ount

ed in

side

ca

bine

t

Bloc

ks

mou

nted

on

a do

or

Bloc

ks m

ount

ed in

side

ca

bine

tLa

belin

gBl

ocks

m

ount

ed o

n a

door

Bloc

ks m

ount

ed in

side

ca

bine

tLa

belin

gBl

ocks

mou

nted

on

a d

oor

Bloc

ks m

ount

ed in

side

ca

bine

tLa

belin

gBl

ocks

mou

nted

on

a d

oor

1BV

-023

-SE-

4070

1BV

-001

-RU

-307

01

BV-0

01-

RU-3

070

1BV

-001

-RU

-307

0

2BV

-019

-SE-

4077

2BU

-009

-SE-

1774

2BU

-011

-SE-

1774

2BU

-009

-SE-

1774

3BV

-027

-SE-

4074

3BU

-009

-SE-

1774

3BU

-011

-SE-

1774

3BU

-009

-SE-

1774

4BA

-033

-SE-

0004

4BU

-009

-SE-

1774

4BU

-011

-SE-

1774

4BU

-009

-SE-

1774

5BV

-012

-SE-

4470

5BU

-009

-SE-

1774

5BU

-009

-SE-

1774

5BU

-009

-SE-

1774

66

BU-0

09-S

E-17

746

BU-0

09-S

E-17

746

BU-0

09-S

E-17

74

77

BU-0

09-S

E-17

747

BU-0

09-S

E-17

747

BU-0

09-S

E-17

74

88

BU-0

09-S

E-17

748

BU-0

09-S

E-18

748

BU-0

09-S

E-18

74

99

BU-0

09-S

E-17

749

BU-0

09-S

E-18

749

BU-0

09-S

E-18

74

1010

BU-0

09-S

E-18

7410

BU-0

09-S

E-18

7410

BU-0

09-S

E-18

74

1111

BU-0

09-S

E-18

7411

BU-0

09-S

E-17

7411

BU-0

09-S

E-17

74

1212

BU-0

09-S

E-18

7412

BU-0

09-S

E-17

7412

BU-0

09-S

E-17

74

1313

1313

Cabi

net

dim

ensi

ons

(HxL

xW)

2000

x800

x400

2000

x800

x400

2000

x800

x400

2000

x800

x400

Addi

tiona

l eq

uipm

ent

Voltm

eter

, lig

htin

g, ~

220

V la

mps

Ligh

ting,

~22

0 V

lam

psLi

ghtin

g, ~

220

V la

mps

Ligh

ting,

~22

0 V

lam

ps

Page 11: Low voltage switchgears

11

LOW VOLTAGE SWITCHGEARS

www.abs-zeim.ru

11

Pane

l typ

eKS

ATO

serie

s ca

bine

t

Met

al w

ork

type

UVRU

-SH-

11-4

074-

SNOP

UHL

4UV

RU-S

H-31

-307

4-SN

OP U

HL4

UVRU

-SH-

31-3

074-

SNOP

UHL

4UV

RU-S

H-31

-307

4-SN

OP U

HL4

Cabi

net N

o1

23

4

Type

blo

ck

Bloc

ks m

ount

ed in

side

ca

bine

t

Bloc

ks

mou

nted

on

a do

or

Bloc

ks m

ount

ed in

side

ca

bine

tLa

belin

gBl

ocks

m

ount

ed o

n a

door

Bloc

ks m

ount

ed in

side

ca

bine

tLa

belin

gBl

ocks

mou

nted

on

a d

oor

Bloc

ks m

ount

ed in

side

ca

bine

tLa

belin

gBl

ocks

mou

nted

on

a d

oor

1BV

-023

-SE-

4070

1BV

-001

-RU

-307

01

BV-0

01-

RU-3

070

1BV

-001

-RU

-307

0

2BV

-019

-SE-

4077

2BU

-009

-SE-

1774

2BU

-011

-SE-

1774

2BU

-009

-SE-

1774

3BV

-027

-SE-

4074

3BU

-009

-SE-

1774

3BU

-011

-SE-

1774

3BU

-009

-SE-

1774

4BA

-033

-SE-

0004

4BU

-009

-SE-

1774

4BU

-011

-SE-

1774

4BU

-009

-SE-

1774

5BV

-012

-SE-

4470

5BU

-009

-SE-

1774

5BU

-009

-SE-

1774

5BU

-009

-SE-

1774

66

BU-0

09-S

E-17

746

BU-0

09-S

E-17

746

BU-0

09-S

E-17

74

77

BU-0

09-S

E-17

747

BU-0

09-S

E-17

747

BU-0

09-S

E-17

74

88

BU-0

09-S

E-17

748

BU-0

09-S

E-18

748

BU-0

09-S

E-18

74

99

BU-0

09-S

E-17

749

BU-0

09-S

E-18

749

BU-0

09-S

E-18

74

1010

BU-0

09-S

E-18

7410

BU-0

09-S

E-18

7410

BU-0

09-S

E-18

74

1111

BU-0

09-S

E-18

7411

BU-0

09-S

E-17

7411

BU-0

09-S

E-17

74

1212

BU-0

09-S

E-18

7412

BU-0

09-S

E-17

7412

BU-0

09-S

E-17

74

1313

1313

Cabi

net

dim

ensi

ons

(HxL

xW)

2000

x800

x400

2000

x800

x400

2000

x800

x400

2000

x800

x400

Addi

tiona

l eq

uipm

ent

Voltm

eter

, lig

htin

g, ~

220

V la

mps

Ligh

ting,

~22

0 V

lam

psLi

ghtin

g, ~

220

V la

mps

Ligh

ting,

~22

0 V

lam

ps

VRU8-1N (UVRU-Y-12) input devicesUVRU-Y-12 devices are designed for input and distribution of three-phase 50 Hz 380/220 V current in power networks with a TN-S, TN-C-S solid-grounded neutral, for protection from overloads, short circuits and to carry out infrequent routine switchings.

DesignAn input device case is made of sheet metal housing a knife switch or a rotary switch and fuses. Input devices are classified according to the nominal current and type of input block. Cable input and output is located either on top or on the bottom side of a case.

Major specifications of switchgears and their components Table 6

Product series Nominal current, A Circuit drawingOverall

dimensions (HxLxW), mm

Analog

UVRU-Y-12-01 Up to 100 700х700х200 VRU8-1N-004

UVRU-Y-12-02 Up to 250 700х900х200 VRU8-1N-002

Example of an order of a wall-mounted input device installed in a metal case, using circuit No1 designed to operate nominal current up to 100 A, 380 V, 50 Hz, without control circuits, in general industrial use version, with bottom cable inlet, single-sided accessibility, fixed type of components mounting, in UHL climatic version, allocation category – 4, equipped with a VA47-100 three-pole breaker for 100 A, with a three-pole switch for 100 A, with an electric three-phase meter and two VA47-63 single-pole switches for signal circuits: UVRU-Y-12-01-SNOP UHL4 (KSATO series)

Product view

to load

Input 1 Input 2

Input 1 Input 2

to load

Page 12: Low voltage switchgears

LOW VOLTAGE SWITCHGEARS

www.abs-zeim.ru

1212

PR8503, PR11 distribution devices (UVRU-Y-22)

UVRU-Y-22 switchgears are designed for electric power distribution and electric units protection from short circuits and overloads, for infrequent routing switchings of lighting circuits, for protection of AC three-phase 380/220V 50Hz lighting networks from overloads and short circuits. Each switchgear is equipped with a number of automatic switches depending on the number of outgoing lines.

DesignAn UVRU-Y-22 type distribution device is assembled in a unified metal case which houses all the equipment. Cable inlets and outputs are installed on top or bottom side of a case.

Product series Input circuit breakerNominal

current, A

Number of 18mm distribution modules, not

more than

Overall dimensions (HxLxW)

Electrical circuit No Analog

UVRU-Y-22-03 - Up to 63

18

350х300х120 5 VRU8-3N-301

UVRU-Y-23-03 - Up to 63 350х300х120 5 VRU8-3В-301

UVRU-Y-22-04 + Up to 63 350х300х120 6 VRU8-3N-302

UVRU-Y-23-04 + Up to 63 350х300х120 6 VRU8-3V-302

UVRU-Y-22-05 - Up to 63

24

400х310х120 5 VRU8-3N-303

UVRU-Y-23-05 - Up to 63 400х320х120 5 VRU8-3V-303

UVRU-Y-22-06 + Up to 63 400х310х120 6 VRU8-3N-304

UVRU-Y-23-06 + Up to 63 400х320х120 6 VRU8-3V-304

UVRU-Y-22-07 - Up to 100

48

620х310х120 5 VRU8-3N-305

UVRU-Y-23-07 - Up to 100 630х320х120 5 VRU8-3V-305

UVRU-Y-22-08 + Up to 100 620х310х120 6 VRU8-3N-306

UVRU-Y-23-08 + Up to 100 630х320х120 6 VRU8-3V-306

UVRU-Y-22-09 - Up to 10024

400х310х120 5 VRU8-3N-307

UVRU-Y-23-09 - Up to 100 400х320х120 5 VRU8-3V-307

UVRU-Y-22-10 + Up to 10018

270х440х120 6 VRU8-3N-308

UVRU-Y-23-10 + Up to 100 280х450х120 6 VRU8-3V-308

UVRU-Y-22-11 + Up to 10036

540х310х120 6 VRU8-3N-309

UVRU-Y-23-11 + Up to 100 550х320х120 6 VRU8-3V-309

UVRU-Y-22-11 - Up to 10048

620х310х120 5 VRU8-3N-310

UVRU-Y-23-11 - Up to 100 630х320х120 5 VRU8-3V-310

UVRU-Y-22-12 - Up to 10054

540х440х120 5 VRU8-3N-311

UVRU-Y-22-13 + Up to 100 540х440х120 6 VRU8-3N-312

UVRU-Y-22-14 + 100 - 250 10 800х650х250 6 VRU8-3N-313

Major specifications of switchgears and their components Table 7

Product view

Page 13: Low voltage switchgears

13

LOW VOLTAGE SWITCHGEARS

www.abs-zeim.ru

13

Major specifications and overall dimensions Table8

Product series

Input automatic circuit breaker

nominal current, A

Cabinet nominal current, A

Overall dimensions

(HxLxW), mmInput switch

Automatic breaker

Analog1-pole 3-pole

UVRU-Y-22-20- 90

400х750х200- 6 -

PR11-1045

UVRU-Y-22-21 400х650х200 PR11-3045

UVRU-Y-22-22100 90

500х750х200+ 6 -

PR11-1046

UVRU-Y-22-23 500х650х200 PR11-3046

UVRU-Y-22-24- 90

400х750х200- - 2

PR11-1047

UVRU-Y-22-25 400х650х200 PR11-3047

UVRU-Y-22-26100 90

500х750х200+ - 2

PR11-1048

UVRU-Y-22-27 500х650х200 PR11-3048

UVRU-Y-22-28- 90

400х750х200- 3 1

PR11-1049

UVRU-Y-22-29 400х650х200 PR11-3049

UVRU-Y-22-30100 90

500х750х200+ 3 1

PR11-1050

UVRU-Y-22-31 500х650х200 PR11-3050

UVRU-Y-22-32- 225

500х750х200- 12 -

PR11-1051

UVRU-Y-22-33 500х650х200 PR11-3051

UVRU-Y-22-34250 225

1000х750х250+ 12 -

PR11-1052

UVRU-Y-22-35 1000х650х250 PR11-3052

UVRU-Y-22-36- 225

500х750х200- - 4

PR11-1053

UVRU-Y-22-37 500х650х200 PR11-3053

UVRU-Y-22-38250 225

1000х750х250+ - 4

PR11-1054

UVRU-Y-22-39 1000х650х250 PR11-3054

UVRU-Y-22-40- 225

500х750х200- 6 2

PR11-1055

UVRU-Y-22-41 500х650х200 PR11-3055

UVRU-Y-22-42250 225

1000х750х250+ 6 2

PR11-1056

UVRU-Y-22-43 1000х650х250 PR11-3056

UVRU-Y-22-44- 225

600х750х200- 18 -

PR11-1057

UVRU-Y-22-45 600х650х200 PR11-3057

UVRU-Y-22-46250 225

1000х750х250+ 18 -

PR11-1058

UVRU-Y-22-47 1000х650х250 PR11-3058

UVRU-Y-22-48- 225

600х750х200- - 6

PR11-1059

UVRU-Y-22-49 600х650х200 PR11-3059

UVRU-Y-22-50250 225

1000х750х250+ - 6

PR11-1060

UVRU-Y-22-51 1000х650х250 PR11-3060

UVRU-Y-22-52- 225

600х750х200- 12 2

PR11-1061

UVRU-Y-22-53 600х650х200 PR11-3061

UVRU-Y-22-54250 225

1000х750х250+ 12 2

PR11-1062

UVRU-Y-22-55 1000х650х250 PR11-3062

UVRU-Y-22-56- 225

600х750х200- 6 4

PR11-1063

UVRU-Y-22-57 600х650х200 PR11-3063

UVRU-Y-22-58250 225

1000х750х250+ 6 4

PR11-1064

UVRU-Y-22-59 1000х650х250 PR11-3064

UVRU-Y-22-60- 225

800х750х200- 24 -

PR11-1065

UVRU-Y-22-61 800х650х200 PR11-3065

Page 14: Low voltage switchgears

LOW VOLTAGE SWITCHGEARS

www.abs-zeim.ru

1414

Table 8 (continued)

UVRU-Y-22-62250 225

1000х750х250+ 24 -

PR11-1066

UVRU-Y-22-63 1000х650х250 PR11-3066

UVRU-Y-22-64- 225

800х750х200- - 8

PR11-1067

UVRU-Y-22-65 800х650х200 PR11-3067

UVRU-Y-22-66250 225

1000х750х250+ - 8

PR11-1068

UVRU-Y-22-67 1000х650х250 PR11-3068

UVRU-Y-22-68- 225

800х750х200- 18 2

PR11-1069

UVRU-Y-22-69 800х650х200 PR11-3069

UVRU-Y-22-70250 225

1000х750х250+ 18 2

PR11-1070

UVRU-Y-22-71 1000х650х250 PR11-3070

UVRU-Y-22-72- 225

800х750х200- 12 4

PR11-1071

UVRU-Y-22-73 800х650х200 PR11-3071

UVRU-Y-22-74250 225

1000х750х250+ 12 4

PR11-1072

UVRU-Y-22-75 1000х650х250 PR11-3072

UVRU-Y-22-76- 225

800х750х200- 6 6

PR11-1073

UVRU-Y-22-77 800х650х200 PR11-3073

UVRU-Y-22-78250 225

1000х750х250+ 6 6

PR11-1074

UVRU-Y-22-79 1000х650х250 PR11-3074

UVRU-Y-22-80- 225

800х750х200- 30 -

PR11-1075

UVRU-Y-22-81 800х650х200 PR11-3075

UVRU-Y-22-82250 225

1200х750х250+ 30 -

PR11-1076

UVRU-Y-22-83 1200х650х250 PR11-3076

UVRU-Y-22-84

- 225

800х750х200

- - 10

PR11-1077

UVRU-Y-22-85 800х650х200 PR11-3077

UVRU-Y-22-86 800х650х200 PR11-7077*

UVRU-Y-22-87

250 225

1200х750х250

+ - 10

PR11-1078

UVRU-Y-22-88 1200х650х250 PR11-3078

UVRU-Y-22-89 1200х650х250 PR11-7078*

UVRU-Y-22-90- 225

800х750х200- 24 2

PR11-1079

UVRU-Y-22-91 800х650х200 PR11-3079

UVRU-Y-22-92250 225

1200х750х250+ 24 2

PR11-1080

UVRU-Y-22-93 1200х650х250 PR11-3080

UVRU-Y-22-94- 225

800х750х200- 18 4

PR11-1081

UVRU-Y-22-95 800х650х200 PR11-3081

UVRU-Y-22-96250 225

1200х750х250+ 18 4

PR11-1082

UVRU-Y-22-97 1200х650х250 PR11-3082

UVRU-Y-22-98- 225

800х750х200- 12 6

PR11-1083

UVRU-Y-22-99 800х650х200 PR11-3083

UVRU-Y-22-100250 225

1200х750х250+ 12 6

PR11-1084

UVRU-Y-22-101 1200х650х250 PR11-3084

UVRU-Y-22-102- 225

800х750х200- 6 8

PR11-1085

UVRU-Y-22-103 800х650х200 PR11-3085

Серия ящикаНом. ток вводного

автомата, А

Ном. ток шкафа, А

Размеры (HxLxB), мм

Наличие вводного

выключателя

Кол-во автоматических выключателей Аналог

1 полюсных 3 полюсных

Product series

Input automatic circuit breaker

nominal current, A

Cabinet nominal current, A

Overall dimensions

(HxLxW), mmInput switch

Automatic breaker

Analog1-pole 3-pole

* - floor cabinet design

Page 15: Low voltage switchgears

15

LOW VOLTAGE SWITCHGEARS

www.abs-zeim.ru

15

UVRU-Y-22-104250 225

1200х750х250+ 6 8

PR11-1086

UVRU-Y-22-105 1200х650х250 PR11-3086

UVRU-Y-22-106- 360

600х750х200- 18 -

PR11-1087

UVRU-Y-22-107 600х650х200 PR11-3087

UVRU-Y-22-108400 360

1000х750х250+ 18 -

PR11-1088

UVRU-Y-22-109 1000х650х250 PR11-3088

UVRU-Y-22-110- 360

600х750х200- - 6

PR11-1089

UVRU-Y-22-111 600х650х200 PR11-3089

UVRU-Y-22-112400 360

1000х750х250+ - 6

PR11-1090

UVRU-Y-22-113 1000х650х250 PR11-3090

UVRU-Y-22-114- 360

600х750х200- 12 2

PR11-1091

UVRU-Y-22-115 600х650х200 PR 11-3091

UVRU-Y-22-116400 360

1000х750х250+ 12 2

PR11-1092

UVRU-Y-22-117 1000х650х250 PR11-3092

UVRU-Y-22-118- 360

600х750х200- 6 4

PR11-1093

UVRU-Y-22-119 600х650х200 PR11-3093

UVRU-Y-22-120400 360

1000х750х250+ 6 4

PR11-1094

UVRU-Y-22-121 1000х650х250 PR11-3094

UVRU-Y-22-122- 360

800х750х200- 24 -

PR11-1095

UVRU-Y-22-123 800х650х200 PR11-3095

UVRU-Y-22-124400 360

1200х750х250+ 24 -

PR11-1096

UVRU-Y-22-125 1200х650х250 PR11-3096

UVRU-Y-22-126- 360

800х750х200- - 8

PR11-1097

UVRU-Y-22-127 800х650х200 PR11-3097

UVRU-Y-22-128400 360

1200х750х250+ - 8

PR11-1098

UVRU-Y-22-129 1200х650х250 PR11-3098

UVRU-Y-22-130- 360

800х750х200- 18 2

PR11-1099

UVRU-Y-22-131 800х650х200 PR11-3099

UVRU-Y-22-132400 360

1200х750х250+ 18 2

PR11-1100

UVRU-Y-22-133 1200х650х250 PR11-3100

UVRU-Y-22-134- 360

800х750х200- 12 4

PR11-1101

UVRU-Y-22-135 800х650х200 PR11-3101

UVRU-Y-22-136400 360

1200х750х250+ 12 4

PR11-1102

UVRU-Y-22-137 1200х650х250 PR11-3102

UVRU-Y-22-138- 360

800х750х200- 6 6

PR11-1103

UVRU-Y-22-139 800х650х200 PR11-3103

UVRU-Y-22-140400 360

1200х750х250+ 6 6

PR11-1104

UVRU-Y-22-141 1200х650х250 PR11-3104

UVRU-Y-22-142- 360

800х750х200- 30 -

PR11-1105

UVRU-Y-22-143 800х650х200 PR11-3105

Product series

Input automatic circuit breaker

nominal current, A

Cabinet nominal current, A

Overall dimensions

(HxLxW), mmInput switch

Automatic breaker

Analog1-pole 3-pole

Table 8 (continued)

Page 16: Low voltage switchgears

LOW VOLTAGE SWITCHGEARS

www.abs-zeim.ru

1616

Table 8 (continued)

UVRU-Y-22-144400 360

1200х750х250+ 30 -

PR11-1106

UVRU-Y-22-145 1200х650х250 PR11-3106

UVRU-Y-22-146

- 360

800х750х200

- - 10

PR11-1107

UVRU-Y-22-147 800х650х200 PR11-3107

UVRU-Y-22-148 800х650х200 PR11-7107*

UVRU-Y-22-149

400 360

1200х750х250

+ - 10

PR11-1108

UVRU-Y-22-150 1200х650х250 PR11-3108

UVRU-Y-22-151 1200х650х250 PR11-7108*

UVRU-Y-22-152- 360

800х750х200- 24 2

PR11-1109

UVRU-Y-22-153 800х650х200 PR11-3109

UVRU-Y-22-154400 360

1200х750х250+ 24 2

PR11-1110

UVRU-Y-22-155 1200х650х250 PR11-3110

UVRU-Y-22-156- 360

800х750х200- 18 4

PR11-1111

UVRU-Y-22-157 800х650х200 PR11-3111

UVRU-Y-22-158400 360

1200х750х250+ 18 4

PR11-1112

UVRU-Y-22-159 1200х650х250 PR11-3112

UVRU-Y-22-160- 360

800х750х200- 12 6

PR11-1113

UVRU-Y-22-161 800х650х200 PR11-3113

UVRU-Y-22-162400 360

1200х750х250+ 12 6

PR11-1114

UVRU-Y-22-163 1200х650х250 PR11-3114

UVRU-Y-22-164- 360

800х750х200- 6 8

PR11-1115

UVRU-Y-22-165 800х650х200 PR11-3115

UVRU-Y-22-166400 360

1200х750х250+ 6 8

PR11-1116

UVRU-Y-22-167 1200х650х250 PR11-3116

UVRU-Y-22-168- 225

600х750х250- 6 4

PR11-1117

UVRU-Y-22-169 600х650х200 PR11-3117

UVRU-Y-22-170250 225

1000х750х250+ - 4

PR11-1118

UVRU-Y-22-171 1000х750х250 PR11-3118

UVRU-Y-22-172- 360

800х750х200- - 6

PR11-3119

UVRU-Y-22-173 800х750х200 PR11-7119*

UVRU-Y-22-174400 360

1200х750х250+ - 6

PR11-3120

UVRU-Y-22-175 1200х750х250 PR11-7120*

UVRU-Y-22-176- 567

1000х750х250- - 8

PR11-3121

UVRU-Y-22-177 1000х750х200 PR11-7121*

UVRU-Y-22-178630 567

1200х750х250+ - 8

PR11-3122

UVRU-Y-22-179 1200х750х250 PR11-7122*

UVRU-Y-22-180- 567

1200х750х250- - 12

PR11-3123

UVRU-Y-22-181 1200х750х200 PR11-7123*

UVRU-Y-22-182630 567

1500х750х250+ - 12

PR11-3124

UVRU-Y-22-183 1500х750х250 PR11-7124*

Product series

Input automatic circuit breaker

nominal current, A

Cabinet nominal current, A

Overall dimensions

(HxLxW), mmInput switch

Automatic breaker

Analog1-pole 3-pole

* - floor cabinet design

Page 17: Low voltage switchgears

17

LOW VOLTAGE SWITCHGEARS

www.abs-zeim.ru

17

Overall dimensions of wall-mounted switchgears stated in the Table 11 Table 9

DimensionSize

H L W

1 650 500 220

2 800 600 250

3 1200 750 300

Overall dimensions of floor-mounted switchgears stated in the Table 11 Table 10

DimensionSize

H L W

1 1200 750 300

2 1600 700 300

3 1800 800 450

Major specifications Table 11

UVRU-Y-22-201-…-PV IP54 1 1 6 - 1001-2UHL2,2Т2

UVRU-Y-21-201-…-PN IP54 2 1 6 - 2001-6UHL2,6Т2

UVRU-Y-22-201-…-PV IP21 1 1 6 - 1001-1 UHL3

UVRU-Y-23-201-…-PV IP21 1 1 6 - 3001-1 UHL3

UVRU-Y-23-201-…-PV IP21 1 1 6 - 3001-1Т3,3Т3

UVRU-Y-22-201-…-PN IP21 2 1 6 - 1001-5 UHL3

UVRU-Y-21-201-…-PN IP21 2 1 6 - 2001-5 UHL3

UVRU-Y-23-201-…-PN IP21 2 1 6 - 3001-5UHL3,3Т3

UVRU-Y-22-202-…-PV IP54 2 1 8 - 1002-2UHL2,2Т2

UVRU-Y-21-202-…-PV IP54 2 1 8 - 2002-2UHL2,2Т2

UVRU-Y-22-202-…-PN IP54 3 1 8 - 1002-6UHL2,6Т2

UVRU-Y-21-202-…-PN IP54 3 1 8 - 2002-6UHL2,6Т2

UVRU-Y-22-202-…-PV IP21 2 1 8 - 1002-1 UHL3

UVRU-Y-21-202-…-PV IP21 2 1 8 - 2002-1 UHL3

UVRU-Y-23-202-…-PV IP21 2 1 8 - 3002-1 UHL3

UVRU-Y-23-202-…-PV IP21 2 1 8 - 3002-1Т3

UVRU-Y-22-202-…-PN IP21 3 1 8 - 1002-5 UHL3

UVRU-Y-21-202-…-PN IP21 3 1 8 - 2002-5 UHL3

UVRU-Y-22-203-…-PV IP54 2 1 10 - 1003-2UHL2,2Т2

UVRU-Y-21-203-…-PV IP54 2 1 10 - 2003-2UHL2,2Т2

UVRU-Y-22-203-…-PN IP54 3 1 10 - 1003-6UHL2,6Т2

UVRU-Y-21-203-…-PN IP54 3 1 10 - 2003-6UHL2,6Т2

UVRU-Y-22-203-…-PV IP21 2 1 10 - 1003-1 UHL2

UVRU-Y-22-203-…-PN IP21 2 1 10 - 1003-13Т2

UVRU-Y-21-203-…-PV IP21 2 1 10 - 2003-1 UHL3

UVRU-Y-21-203-…-PN IP21 2 1 10 - 2003-3 UHL3

Switchgear seriesProtection

classDimension

Number of circuit breakersAnalogs

InputDistribution

0,6 - 63 А 16 - 250 А PR8503, PR8703

Page 18: Low voltage switchgears

LOW VOLTAGE SWITCHGEARS

www.abs-zeim.ru

1818

Switchgear seriesProtection

classDimension

Number of circuit breakersAnalogs

InputDistribution

0,6 - 63 А 16 - 250 А PR8503, PR8703

Table 11 (continued)

UVRU-Y-23-203-…-PV IP21 2 1 10 - 3003-1 UHL3

UVRU-Y-23-203-…-PN IP21 2 1 10 - 3003-3 UHL3

UVRU-Y-22-203-…-PN IP21 2 3 10 - 1003-5 UHL3

UVRU-Y-21-203-…-PN IP21 2 3 10 - 2003-5 UHL3

UVRU-Y-23-203-…-PV IP21 2 3 10 - 3003-1Т3

UVRU-Y-23-203-…-PN IP21 2 3 10 - 3003-3Т3

UVRU-Y-22-204-…-PV IP54 2 1 12 - 1004-2UHL2,2Т2

UVRU-Y-21-204-…-PV IP54 2 1 12 - 2004-2UHL2,2Т2

UVRU-Y-22-204-…-PN IP54 2 1 12 - 1004-4UHL2,4Т2

UVRU-Y-21-204-…-PN IP54 2 1 12 - 2004-4UHL2,4Т2

UVRU-Y-22-204-…-PN IP54 3 1 12 - 1004-6UHL2,6Т2

UVRU-Y-21-204-…-PN IP54 3 1 12 - 2004-6UHL2,6Т2

UVRU-Y-22-204-…-PV IP21 2 1 12 - 1004-1 UHL3

UVRU-Y-22-204-…-PN IP21 2 1 12 - 1004-3 UHL3

UVRU-Y-21-204-…-PV IP21 2 1 12 - 2004-1 UHL3

UVRU-Y-21-204-…-PN IP21 2 1 12 - 2004-3 UHL3

UVRU-Y-23-204-…-PV IP21 2 1 12 - 3004-1 UHL3

UVRU-Y-23-204-…-PN IP21 2 1 12 - 3004-3 UHL3

UVRU-Y-22-204-…-PN IP21 3 1 12 - 1004-5 UHL3

UVRU-Y-21-204-…-PN IP21 3 1 12 - 2004-5 UHL3

UVRU-Y-23-204-…-PV IP21 3 1 12 - 3004-1Т3

UVRU-Y-23-204-…-PN IP21 3 1 12 - 3004-3Т3

UVRU-Y-22-205-…-PV IP54 2 1 - 4 1005-2UHL2,2Т2

UVRU-Y-21-205-…-PV IP54 2 1 - 4 2005-2UHL2,2Т2

UVRU-Y-22-205-…-PN IP54 2 1 - 4 1005-4UHL2,4Т2

UVRU-Y-21-205-…-PN IP54 2 1 - 4 2005-4UHL2,4Т2

UVRU-Y-22-205-…-PN IP54 3 1 - 4 1005-6UHL2,6Т2

UVRU-Y-21-205-…-PN IP54 3 1 - 4 2005-6UHL2,6Т2

UVRU-Y-22-205-…-PV IP21 2 1 - 4 1005-1 UHL3

UVRU-Y-22-205-…-PN IP21 2 1 - 4 1005-3 UHL3

UVRU-Y-21-205-…-PV IP21 2 1 - 4 2005-1 UHL3

UVRU-Y-21-205-…-PN IP21 2 1 - 4 2005-3 UHL3

UVRU-Y-22-205-…-PN IP21 3 1 - 4 1005-5 UHL3

UVRU-Y-21-205-…-PN IP21 3 1 - 4 2005-5 UHL3

UVRU-Y-22-206-…-PV IP54 2 1 - 6 1006-2UHL2,2Т2

UVRU-Y-21-206-…-PV IP54 2 1 - 6 2006-2UHL2,2Т2

UVRU-Y-22-206-…-PN IP54 2 1 - 6 1006-4UHL2,4Т2

UVRU-Y-21-206-…-PN IP54 2 1 - 6 2006-4UHL2,4Т2

UVRU-Y-22-206-…-PN IP54 3 1 - 6 1006-6UHL2,6Т2

UVRU-Y-21-206-…-PN IP54 3 1 - 6 2006-6UHL2,6Т2

UVRU-Y-22-206-…-PV IP21 2 1 - 6 1006-1 UHL3

UVRU-Y-22-206-…-PN IP21 2 1 - 6 1006-3 UHL3

Page 19: Low voltage switchgears

19

LOW VOLTAGE SWITCHGEARS

www.abs-zeim.ru

19

Switchgear seriesProtection

classDimension

Number of circuit breakersAnalogs

InputDistribution

0,6 - 63 А 16 - 250 А PR8503, PR8703

Table 11 (continued)

UVRU-Y-21-206-…-PV IP21 2 1 - 6 2006-1 UHL3

UVRU-Y-21-206-…-PN IP21 2 1 - 6 2006-3 UHL3

UVRU-Y-22-206-…-PN IP21 3 1 - 6 1006-5 UHL3

UVRU-Y-21-206-…-PN IP21 3 1 - 6 2006-5 UHL3

UVRU-Y-22-207-…-PV IP54 1 1 2 2 1007-2UHL2,2Т2

UVRU-Y-22-207-…-PN IP54 1 1 2 2 1007-4UHL2,4Т2

UVRU-Y-22-207-…-PN IP54 2 1 2 2 1007-6UHL2,6Т2

UVRU-Y-21-207-…-PN IP54 2 1 2 2 2007-6UHL2,6Т2

UVRU-Y-22-207-…-PV IP21 1 1 2 2 1007-1 UHL3

UVRU-Y-22-207-…-PN IP21 1 1 2 2 1007-3 UHL3

UVRU-Y-22-207-…-PN IP21 2 1 2 2 1007-5 UHL3

UVRU-Y-21-207-…-PN IP21 2 1 2 2 2007-5 UHL3

UVRU-Y-22-208-…-PV IP54 2 1 4 2 1008-2UHL2,2Т2

UVRU-Y-21-208-…-PV IP54 2 1 4 2 2008-2UHL2,2Т2

UVRU-Y-22-208-…-PN IP54 2 1 4 2 1008-4UHL2,4Т2

UVRU-Y-21-208-…-PN IP54 2 1 4 2 2008-4UHL2,4Т2

UVRU-Y-22-208-…-PN IP54 3 1 4 2 1008-6UHL2,6Т2

UVRU-Y-21-208-…-PN IP54 3 1 4 2 2008-6UHL2,6Т2

UVRU-Y-22-208-…-PV IP21 2 1 4 2 1008-1 UHL3

UVRU-Y-22-208-…-PN IP21 2 1 4 2 1008-3 UHL3

UVRU-Y-21-208-…-PV IP21 2 1 4 2 2008-1 UHL3

UVRU-Y-21-208-…-PN IP21 2 1 4 2 2008-3 UHL3

UVRU-Y-22-208-…-PN IP21 3 1 4 2 1008-5 UHL3

UVRU-Y-21-208-…-PN IP21 3 1 4 2 2008-5 UHL3

Page 20: Low voltage switchgears

LOW VOLTAGE SWITCHGEARS

www.abs-zeim.ru

2020

UVRU-Y-22 series control boxes electric diagrams

Fig. 5 Fig. 6 Fig. 7

Fig. 8 Fig. 9 Fig. 10

Example of an order of a panel-type wall-mounted switchgear with an electric circuit No03, operating nominal current of 63 A and power lines voltage of 380 V 50 Hz, no control lines, general industrial use version, bottom cable inlet, single-side accessibility, fixed mounting of components, UHL climatic version, allocation category 4, no input circuit breaker, equipped with VA47-63 distribution circuit breakers (10 A) – 6 pc.: UVRU-Y-22-03-3870-SNOP UHL4 KSATO series, VA47-63 distribution circuit breakers (10 A) – 6 pc.

~380 V~380 V

~380 V

~380 V

~380 V

~380 V

Page 21: Low voltage switchgears

21

LOW VOLTAGE SWITCHGEARS

www.abs-zeim.ru

21

VRU8-2N (UVRU-Y-42) input and distribution switchgearsUVRU-Y-42 switchgears are designed for input and distribution of 380/220V 50 Hz three-phase alternating current in power networks with a solid-ground neutral and for power lines protection from short circuits and overloads.

Residual current circuit breakers can be installed in order to provide protection from electric shock caused by touching energized open wiring or electric equipment and to prevent combustion caused by long-term flow of drain current and occurrence of short circuits current caused by it.

Wires inlets and outlets are located on top and at the bottom of a case and closed with covers. Maximal section of cable cores and maximal cable diameter is determined by switchgear parameters. Technical dataPanels are equipped with special fastening elements allowing maintenance accessibility from the front side without panels removing. Switchgears manufactured in accordance with the IP54 protection class can be equipped with gland sealings on demand. Switchgears equipped with input circuit breakers are controlled by means of a manual remote drive installed on the external surface of the panel.

Design featuresOperators protection from touching energized elements is provided by a dummy panel. Switchgear controls are located on its external surface. Neutral and grounding buses are located behind the dummy panel.

Number of distribution circuit breakers is determined by a customer but it can not exceed the number of modules that can be installed in a panel. In case an input circuit breaker is installed in a panel then the maximal allowed number of modules decreases.

Product view

Major specifications of switchgears and components Table 12

Component Number of modules

1-position automatic circuit breaker (up to 63 A, 220 V) 1

2-position automatic circuit breaker (up to 63 A, 220 V)2

UZO residual current circuit breaker ~220 V

3-position automatic circuit breaker (up to 63 A, 380 V)3

VKZ-2 combined protection circuit breaker (up to 63 A, 220 V)

4-position automatic circuit breaker (Up to 63 A, 220 V)

4UZO residual current circuit breaker ~220 V

Residual current circuit breaker (Inom. up to 63 A, 380 V)

VKZ-4 combined protection circuit breaker (Inom. up to 63 A, 380 V) 5

Page 22: Low voltage switchgears

LOW VOLTAGE SWITCHGEARS

www.abs-zeim.ru

2222

Major specifications Table 13

SeriesOutput circuit

breaker

Nominal current,

A

Metering device

Current transformer

Number of distribution

modules, not more than

Overall dimensions

(HxLxW), mm

Electric diagram No

Analog1 3

UVRU-Y-42-01 - 50 + - - 12 466х350х170 12 VRU8-2N-101

UVRU-Y-42-02 - 50 + - - 12 496х380х170 12 VRU8-2V-101

UVRU-Y-42-03 + 50 + - - 13 466х350х170 13 VRU8-2N-102

UVRU-Y-42-04 + 50 + - - 13 496х380х170 13 VRU8-2V-102

UVRU-Y-42-05 - 63 - + - 12 466х350х170 14 VRU8-2N-103

UVRU-Y-42-06 - 63 - + - 12 496х380х170 14 VRU8-2V-103

UVRU-Y-42-07 + 63 - + - 12 466х350х170 15 VRU8-2N-104

UVRU-Y-42-08 + 63 - + - 12 496х380х170 15 VRU8-2V-104

UVRU-Y-42-09 - 50 + - - 27 682х350х170 12 VRU8-2N-105

UVRU-Y-42-10 - 50 + - - 27 712х380х170 12 VRU8-2V-105

UVRU-Y-42-11 + 50 + - - 27 682х350х170 13 VRU8-2N-106

UVRU-Y-42-12 + 50 + - - 27 712х380х170 13 VRU8-2V-106

UVRU-Y-42-13 - 100 - + - 30 682х350х170 14 VRU8-2N-107

UVRU-Y-42-14 - 100 - + - 30 712х380х170 14 VRU8-2V-107

UVRU-Y-42-15 + 100 - + - 27 682х350х170 15 VRU8-2N-108

UVRU-Y-42-16 + 100 - + - 27 712х380х170 15 VRU8-2V-108

UVRU-Y-42-17 + 100 +(б) + - 30 750х700х170 16 VRU8-2N-109

UVRU-Y-42-18 + 100 +(б) + - 30 780х730х170 16 VRU8-2V-109

UVRU-Y-42-19 + 250 - + + 30 750х700х170 18 VRU8-2N-110

UVRU-Y-42-20 + 250 - + + 30 780х730х170 18 VRU8-2V-110

UVRU-Y-42-21 + 250 +(б) + +(в) 30 750х700х170 17 VRU8-2N-111

UVRU-Y-42-22 + 250 +(б) + +(в) 30 780х730х170 17 VRU8-2V-111

UVRU-Y-42-23 + 100 - + - 30 466х684х170 15 VRU8-2N-112

UVRU-Y-42-24 + 100 - + - 45 682х684х170 15 VRU8-2N-113

UVRU-Y-42-25 + 250 - + + - 898х694х170 18 VRU8-2N-114

UVRU-Y-42-26 + 250 - + + 60 898х694х170 18 VRU8-2N-115

UVRU-Y-42-27 - 40 + - - 5 380х180х130 12 VRU8-2N-120

UVRU-Y-42-28 - 40 + - - 5 420х220х130 12 VRU8-2V-120

UVRU-Y-42-29 + 40 + - - 3 380х180х130 13 VRU8-2N-121

UVRU-Y-42-30 + 40 + - - 3 420х220х130 13 VRU8-2V-121

Note:(a) As stated in the Table 12.(b) Total load on 220 V network should not exceed 50 A.(c) One meter and a current transformer, two direct connection meters.

Page 23: Low voltage switchgears

23

LOW VOLTAGE SWITCHGEARS

www.abs-zeim.ru

23

Fig. 12 Fig. 13 Fig.14

Fig. 15 Fig. 16 Fig. 17

Fig. 18

UVRU-Y-42 series control boxes electric diagrams

Note: QF1 – single-phase automatic transformer;QF2 – three-phase automatic transformer;P1 – 220 V meter;P2 – 380 V meter;TA – current transformer.

Example of an order of a box-type switchgear using electric circuit No04 and designed for a nominal current of 50 A and power lines voltage of 220 V 50 Hz, without control circuits, in general industrial use version, bottom cable inlet, single-side maintenance accessibility, fixed connection of components, UHL climatic version, 4 allocation category, one single-pole VA-47-63 circuit breaker (50 A), 10 pc. VA47-63 single-pole distribution circuit breakers (3 A) and 3 pc. VA47-63 single-pole distribution circuit breakers (6 A), 220 V electric meter:UVRU-Y-42-04-3740-SNOP UHL4 KSATO series, VA47-63 single-pole input circuit breaker (50 A), VA-47-63 single-pole distribution circuit breakers 10pc. x 3 A, 3 pc. x 6 A.

~220 V~220 V

~380 V

~380 V ~380 V~380 V

~380 V

~380 V~380 V

~220 V~220 V

Page 24: Low voltage switchgears

LOW VOLTAGE SWITCHGEARS

www.abs-zeim.ru

2424

UVRU-Y-32 control boxes are designed for control of electric motors of up to 90 KW power with short-circuited rotor operating in continuous, short-time and intermittent modes. Products of this series comply with the GOST R 51321.1 requirements.

Control boxes are assembled in metal cases with a mounting panel. The following equipment can be installed in accordance with nomenclature and type index: automatic circuit breakers, starters, thermal relays, light indicators and controls (buttons, switches, etc.).

Major specifications Table 14

Box series Type indexOverall dimensions (HxLxW),

mmNote Analog

UVRU-Y-32-01

18...34 400х300х250

Single-feeder, non-reversible, with automatic circuit breaker, a lamp and a button

Y511035...38 500х400х250

39...42 650х500х250

UVRU-Y-32-02

18...34 400х300х250

Single-feeder, non-reversible, with automatic circuit breaker, a lamp, a button and a switch

Y511135...38 500х400х250

39...42 650х500х250

UVRU-Y-32-03

18...34 400х300х250

Single-feeder, non-reversible, with automatic circuit breaker, a lamp and a button

Y511235...38 500х400х250

39...42 650х500х250

UVRU-Y-32-04

18...34 400х300х250

Single-feeder, non-reversible, with automatic circuit breaker, a lamp, a button and a switch

-35...38 500х400х250

39...42 650х500х250

UVRU-Y-32-05

18...34 400х300х250

Two-feeder, non-reversible, with automatic circuit breaker, a button, and a lamp for each feeder

Y511435...38 500х400х250

39...42 800х650х250

UVRU-Y-32-06

18...34 400х300х250

Two-feeder, non-reversible, with automatic circuit breaker, a button, a lamp and a switch for each feeder

Y511535...38 500х400х250

39...42 800х650х250

UVRU-Y-32-07 18...34 400х300х250Two-feeder, non-reversible, with automatic circuit

breaker, a button, and a lamp for each feederY5124

UVRU-Y-32-08 18...34 400х300х250Two-feeder, non-reversible, with automatic circuit

breaker, a button, a lamp and a switch for each feederY5125

UVRU-Y-32-09

31-34 400х300х250

Single-feeder, non-reversible, without automatic circuit breaker, with a button and a lamp

Y513035-38 500х400х250

39-42 650х500х250

UVRU-Y-32-10

31-34 400х300х250

Single-feeder, non-reversible, without automatic circuit breaker, with a button, a lamp and a switch

Y513135-38 500х400х250

39-42 650х500х250

UVRU-Y-32-11 18-34 500х400х250Two-feeder, non-reversible. Without automatic circuit

breaker, with a button and a lamp for each feederY5134

Y5000 (UVRU-Y-32) control boxes

Product view

Page 25: Low voltage switchgears

25

LOW VOLTAGE SWITCHGEARS

www.abs-zeim.ru

25

UVRU-Y-32-12 18-34 400х300х250Two-feeder, non-reversible. Without automatic circuit breaker, with a button, a lamp and a switch for each

feederY5135

UVRU-Y-32-13

18-34 400х300х250

Single-feeder, non-reversible, with an intermediary relay, a button, a lamp and a switch

Y514135-38 500х400х250

39-42 650х500х250

UVRU-Y-32-20

18-34 400х300х250

Single-feeder, reversible, with an automatic circuit breaker, a lamp and a button

Y541035-38 500х400х250

39-42 800х650х250

UVRU-Y-32-21

18-34 400х300х250

Single-feeder, reversible, with an automatic switch, a lamp, a button and a switch

Y541135-38 500х400х250

39-42 800х650х250

UVRU-Y-32-22

18-34 400х300х250

Single-feeder, reversible, with an automatic circuit breaker, a lamp and a button

Y541235-38 500х400х250

39-42 800х650х250

UVRU-Y-32-23

18-34 400х300х250

Single-feeder, reversible, with an automatic switch, a lamp, a button and a switch

Y541335-38 500х400х250

39-42 800х650х250

UVRU-Y-32-24

18-34 400х300х250

Two-feeder, reversible, with an automatic circuit breaker, a lamp and a button for each feeder

Y541435-38 650х500х250

39-41 800х650х250

UVRU-Y-32-25

18-34 400х300х250

Two-feeder, reversible, with an automatic circuit breaker, a lamp, a button and a switch for each feeder

Y541535-38 650х500х250

39-41 800х650х250

UVRU-Y-32-26 22-32 500х400х250Two-feeder, reversible with an automatic circuit

breaker for both feeders, with a button, a lamp and a switch for each feeder

Y5425

UVRU-Y-32-27

31-34 400х300х250

Single-feeder, reversible, without an automatic circuit breaker, with a button and a lamp

Y543035-38 500х400х250

39-42 800х650х250

UVRU-Y-32-28

31-34 400х300х250

Single-feeder, reversible, without automatic circuit breaker, with a button, a lamp and a switch

Y543135-38 500х400х250

39-42 800х650х250

UVRU-Y-32-29 22-34 500х400х250Two-feeder, reversible, with an automatic circuit

breaker for both feeders, with a button and a lamp for each feeder

Y5434

UVRU-Y-32-30 18-34 400х300х250Two-feeder, reversible, without automatic circuit breaker, with a button and a lamp for each feeder

Y5435

UVRU-Y-32-31

18-34 500х400х250

Single-feeder, reversible, with an intermediary relay, a button, a lamp and a switch

Y544135-38 650х500х250

39-42 800х650х250

Table 14 (continued)

Box series Type indexOverall dimensions (HxLxW),

mmNote Analog

Boxes differ in: - electric motor reverse option;- max. number of controlled motors;- control lines power supply: phase voltage, linear voltage, from an independent power source;- presence of circuit breakers: no circuit breakers, circuit breaker for each feeder, one circuit breaker for two or three feeders;- devices mounted on a door: no devices mounted; a button and a signal lamp; a button, a signal lamp and a switch.

Example of an order of a single-feeder non-reversible control box equipped with an automatic circuit breaker, a lamp and a button (installed in a box door), using electric diagram No01, operating a nominal current of 0,63 A and power lines current of 380 V 50 Hz, control lines current of 220 V 50 Hz, in general industrial version, with bottom cable inlet, single-side maintenance accessibility, fixed connection of components, UHL climatic version, 4 allocation category:UVRU-Y-32-01-1874-SNOP UHL4 KSATO series

Page 26: Low voltage switchgears

LOW VOLTAGE SWITCHGEARS

www.abs-zeim.ru

2626

Examples of control boxes electric diagrams

Fig.1 UVRU-Y-32-01 series control boxes electrical diagram Fig.2 UVRU-Y-32-02 series control boxes electrical diagram

Fig.3 UVRU-Y-32-03 series control boxes electrical diagram Fig.4 UVRU-Y-32-04 series control boxes electrical diagram

Fig.5 UVRU-Y-32-06 series control boxes electrical diagram Fig.6 UVRU-Y-32-07 series control boxes electrical diagram

Page 27: Low voltage switchgears

27

LOW VOLTAGE SWITCHGEARS

www.abs-zeim.ru

27

Fig.7 UVRU-Y-32-08 series control boxes electrical diagram Fig.8 UVRU-Y-32-10 series control boxes electrical diagram

Fig.9 UVRU-Y-32-12 series control boxes electrical diagram Fig.10 UVRU-Y-32-13 series control boxes electrical diagram

Fig.11 UVRU-Y-32-21 series control boxes electrical diagram Fig.12 UVRU-Y-32-31 series control boxes electrical diagram

Page 28: Low voltage switchgears

LOW VOLTAGE SWITCHGEARS

www.abs-zeim.ru

2828

Example of an order of a wall-mounted box-type automatic transfer switch using electric diagram No01 and designed to operate nominal current up to 0,63 A and power lines current of 380 A 50 Hz, control lines current of 220 V 50 Hz, single-side maintenance accessibility, fixed type of components mounting, in general industrial use version, with a bottom cable inlet, in UHL climatic version, 4 allocation category: UVRU-Y-52-01-1874-SNOP UHL4 KSATO series.Note: this type of boxes can be supplied without automatic circuit breakers.

SHAP, SHAVR series (UVRU-Y(SH)-52(51)) automatic transfer switchesUVRU-Y(SH)-51(52) boxes and cabinets are designed for automatic switching to backup lighting, power supply and automation circuits in case of main power supply disruption. Consumers transition back to main power supply is carried out automatically upon its restoration.

Operation mode – continuous.

Control panel version – protected, in unified boxes or cabinets depending on required nominal current.

Overall dimensions Table 15

Box series Type index Overall dimensions (HxLxW) Analog

UVRU-Y-5217...38 500х500х200

YAVR, SHAP39...40 800х650х300

UVRU-SH-5141...44 1600х700х450

SHAVR, SHAP45...48 2000х1200х800

Figure 16. – Automatic Transfer Switch box electric diagram*

Product view

Main input

Outgoinglines

Backupinput

Page 29: Low voltage switchgears

29

LOW VOLTAGE SWITCHGEARS

www.abs-zeim.ru

29

SHOS, SHO (UVRU-Y-62) lighting panelsLighting panels are designed for electric circuits distributed switchings on and off and for protection of three-phase AC 380/220 V 50 Hz lighting networks from overloads and short circuits.

Lighting panel of each type is equipped with automatic circuit breakers by the number of outgoing group lines.

Panels can be applied in electric networks using any type of grounding: TN-S, TN-S, TN-C-S, TT, IT with any location of neutral and protective conductors providing protection from electric shock in the process of operation.

Panels are classified by:- presence of input circuit breakers;- maximal number and type of distribution circuit breakers (in single-pole version);- installation location (method): hanging (wall-mounted, column-mounted, mounted on a vertical surface); recessed (in a niche).

Major specifications:Nominal operating voltage – 220/380 V.AC frequency – 50 Hz.Nominal conventional short circuit current – 3 KA.

Fig. 33 UVRU-Y-62-01 series boxes electric diagram Fig. 34 UVRU-Y-62-02 series boxes electric diagram

Fig. 35 UVRU-Y-62-03 series boxes electric diagram Fig. 36 UVRU-Y-62-04 series boxes electric diagram

Input Input

Input

Input

Page 30: Low voltage switchgears

LOW VOLTAGE SWITCHGEARS

www.abs-zeim.ru

3030

PRP-9 (UVRU-P-31) control panelsPRP-9 series panel is an operator workstation designed for control of equipment at power plants and sub-stations.

Desk-type control panels house metering equipment, small-size monitors, displays and indicators. Other modifications of PRP-9 panels house monitors.

Lifting surface of a panel houses buttons, switches, light indicators, mnemonic diagrams, control system keyboards and other devices.

Terminal clamps for AC and DC electric circuits connection are located inside control panels on the side surfaces. Clamps are accessed through a port on the rear side.

Cabinet-type panels with metering equipment installed on the front side and terminal clamps located inside the cabinet on the wiring board are also available on demand.

A technical inquiry from a customer should include:- general view;- list of devices installed stating their specifications;- electric diagram and wiring diagram.

Example of an order of an operational control cabinet-type panel without electric power lines, with control lines using 220 V 50 Hz, in general industrial use version, UHL climatic version, 4 allocation category: KSATO UVRU-P-31-01-0004-SNOP UHL4.

Fig.37 UVRU-Y-62-05 series boxes electric diagram

Example of an order of a hanging lighting panel using electric diagram No01 and designed to operate 63 A nominal current and power lines voltage of 380 V 50 Hz, without control lines, in general industrial use version, with bottom cable inlet, single-side maintenance accessibility, fixed type connection of components, UHL climatic version, 4 allocation category, with one three-pole VA47-63 circuit breaker (63 A) and six single-pole VA47-63 circuit breakers (25 A): UVRU-Y-62-01-3870-SNOP UHL4 KSATO series, VA47-63 three-pole input circuit breaker (63 A); single-pole VA47-63 distribution circuit breakers (25 A) – 6 pc.

Input

Page 31: Low voltage switchgears

31

LOW VOLTAGE SWITCHGEARS

www.abs-zeim.ru

31

BEZ series (UVRU-P-31(32)) gate valves actuators control panelsGate valves actuator control panels are designed for gate valves and other control and shutoff fitting types actuators control. This type panels connect fitting actuators to switchgears.

BEZ series control panels in general industrial use version can be used at combined heat and power plants and other power generating facilities in an indoor environment complying with the II category under GOST 15150-69. BEZ control panels can not be operated in aggressive and volatile environments and in indoor environments containing conductive dust, aggressive gases and fumes in concentration exceeding allowed values as regulated by GOST 12.1005-88.

Operating position in space – vertical, mounted on a pole/pipe by means of a pipe junction withstanding 50 N disconnecting force. Allowed inclination - 5° from vertical.

Parameter Value

Nominal voltage, V 380/220

Electric power line current, Inom, A 25

Control line current, Inom, A 6

Nominal frequency, Hz 50

Protection class IP54

Climatic version U3 under GOST 15150-69

Overall dimensions (HxLxW), mm 340x310x90 (250x300x150)

Weight, kg, not more than 6

Cable On demand

Major specifications Table 16

Note:1. Stated values can be changed according to the customer’s technical inquiry

2. When a metal structure type is not specified the product is supplied in type 1 metal housing.

Product view

Page 32: Low voltage switchgears

LOW VOLTAGE SWITCHGEARS

www.abs-zeim.ru

3232

Nomenclature Electric diagram Analog

UVRU-P-31(32)-112 U3

BEZ-3N(P)-1-S

UVRU-P-31(32)-113 U3

BEZ-0N(P)-1-S

UVRU-P-31(32)-114 U3

-

Type, electric diagrams, field of application Table 17

XS1 - SHR55P31EG3 receptacleXS2 - SHR20P3EG7 receptacle1X - YBX terminals by Klemson SBT, SBQ, SBC - SW2C-11 buttons

XS1 - SHR55P31EG3 receptacleXS2 - SHR20P3EG7 receptacle1X - YBX terminals by Klemson

XS1 - SHR55P31EG3 receptacleXS2 - SHR20P3EG7 receptacle1X - YBX terminals by Klemson SBT, SBQ, SBC - SW2C-11 buttonsSA1 TV1-3 switch

CLOSESBT

STOPSBQ

OPENSBC

CLOSESBT

STOPSBQ

OPENSBC

Page 33: Low voltage switchgears

33

LOW VOLTAGE SWITCHGEARS

www.abs-zeim.ru

33

UVRU-P-31(32)-115 U3

-

UVRU-P-31(32)-116 U3

-

UVRU-P-31(32)-118 U3

BEZ-3N(P)-1-SH

Nomenclature Electric diagram Analog

Table 17 (continued)

XS1 - SHR55P31EG3 receptacleXS2 - SHR20P3EG7 receptacle1X - YBX terminals by Klemson SBT, SBQ, SBC - SW2C-11 buttonsHLR, HKG - ENS-22 light indicator

XS1 - SHR55P31EG3 receptacleXS2 - SHR20P3EG7 receptacle1X - YBX terminals by Klemson SBT, SBQ, SBC - SW2C-11 buttonsHLR, HKG - ENS-22 light indicator

XS1 - SHR55P31EG3 receptacleXS2 - SHR20P3EG7 receptacle1X - YBX terminals by Klemson SBT, SBQ, SBC - SW2C-11 buttons

to gate valves

to gate valves

CLOSESBT

STOPSBQ

OPENSBC

CLOSESBT

STOPSBQ

OPENSBC

CLOSESBT

STOPSBQ

OPENSBC

Page 34: Low voltage switchgears

LOW VOLTAGE SWITCHGEARS

www.abs-zeim.ru

3434

Nomenclature Electric diagram Analog

UVRU-P-31(32)-120 U3

BEZ-0N(P)-1-SH

UVRU-P-31(32)-122 U3

BEZ-0N(P)-2-SH

UVRU-P-31(32)-124 U3

BEZ-3N(P)-2-SH

Table 17 (continued)

XS1 - SHR55P31EG3 receptacleXS2 - SHR20P3EG7 receptacle1X - YBX terminals by Klemson

XS1 - SHR55P31EG3 receptacle1X - YBX terminals by Klemson

XS1 - SHR55P31EG3 receptacle1X - YBX terminals by Klemson SBT, SBQ, SBC - SW2C-11 buttons

CLOSESBT

STOPSBQ

OPENSBC

Page 35: Low voltage switchgears

35

LOW VOLTAGE SWITCHGEARS

www.abs-zeim.ru

35

UVRU-P-31(32)-126 U3

BEZ-0N(P)-3-V3

UVRU-P-31(32)-128 U3

BEZ-3N(P)-3-V3

UVRU-P-31(32)-130 U3

BEZ-0N(P)-3-VR

Nomenclature Electric diagram Analog

Example of an order of a cabinet-type gate valve actuators control panel using electric circuit No130, in general industrial use version, with bottom cable inlet, equipped with a cable, in U climatic version, 3 allocation category: UVRU-P-31-130-3474-SNOP U3, with KSATO series cable.

Table 17 (continued)

CLOSESBT

STOPSBQ

OPENSBC

XS1, XS3 - SHR20P3EG7 receptacleXS2 - SHR40P16EG2 receptacle1X - YBX terminals by Klemson

XS1 - SHR40P16EG2 receptacleXS2 - SHR36P5EG11 receptacleXS3 - SHR20P4EG8 receptacle1X - YBX terminals by Klemson SBT, SBQ, SBC - SW2C-11 buttons

XS1 - SHR40P16EG2 receptacleXS2 - SHR36P5EG11 receptacleXS3 - SHR20P4EG8 receptacle1X - YBX terminals by Klemson

Page 36: Low voltage switchgears

LOW VOLTAGE SWITCHGEARS

www.abs-zeim.ru

3636

Customized low-voltage switchgearsBesides the products shown in the present catalogue our company manufactures customized switchgears based on customer’s or own technical documentation. Highly qualified specialists would provide assistance in equipment engineering, design of electric diagrams, offer different configuration variants.

Moreover, «ABS Electro» is experienced in implementation of serial products such as RTZO, Y5000 and other modern equipment to perform various functions, e.g. to represent data on network, mechanisms, switches state by means of digital systems (so called smart RTZOs). Our company is also capable of implementation of projects involving microprocessor based equipment, soft starters, frequency converters, etc.

Intermediary relay cabinet used for discrete signals formation in hardware-

software complexes

Valves control cabinet with automatic regulation option

Valves control cabinet with automatic regulation option (microprocessor-

based)

Local control touch-screen panel Gate valves control panelGate valve control panel with automatic

control function

Page 37: Low voltage switchgears

37

LOW VOLTAGE SWITCHGEARS

www.abs-zeim.ru

37

KTP series transformer substations

250…2500 KVA single-ended and double-ended transformer substations (employing two transformers) with cable and overhead inlets are designed to receive three-phase industrial frequency alternating current of 6-10 KV, its transformation into 0,4 KV 50 Hz current and distribution to industrial consumers.

Transformer substations consist of a number of switchgear cabinets:• inputcabinets(businlet,cableinlet);• sectionalizingcabinets;• commondevicescabinets;• transformerscontrolcabinets;• outgoinglinescabinets.

Hardware-software complex control, indication, protection and automation circuits are based on electromechanical relays. Microprocessor-based versions are also available.

Nomenclature structure

SpecificationsNominal power of a power transformer, KVA: 250; 400; 630; 1000; 1600; 2500.Nominal voltage at VN inlet: 6; 10 KV.Nominal voltage at NN outlet: 0,4 KV.

Short-time thermal withstand current at NN outlet (applied for 1 sec):- for 400 KVA complex – 10 KA;- for 630 and 1000 KVA – 20 KA;- for 1600 KVA – 30 KA;- for 2500 KVA – 40 KA.

Short-time thermal withstand current at VN inlet (applied for 1 sec): 20 KA.

Climatic version and allocation category under GOST 15150.

VN inlet and NN outlet version:K – cable;V – overhead.

High-voltage power supply connection:P – double-ended;T – single-ended.

Development year: 2008

Nominal voltage at NN outlet: 0,4; 0,69 KV.

Nominal voltage at VN inlet: 6; 10 KV.

Power transformer: 250; 400; 630; 1000; 1600; 2500 KVA.

Indoor use industrial transformer sub-station

Number of transformers used (not stated if 1)

X KTPP – X / X / X – 2008 – X – XX X

Page 38: Low voltage switchgears

LOW VOLTAGE SWITCHGEARS

www.abs-zeim.ru

3838

KTP series transformer sub-station (single row of cabinets)

KTP series transformer sub-station (two rows of cabinets)

Face

Page 39: Low voltage switchgears

39

LOW VOLTAGE SWITCHGEARS

www.abs-zeim.ru

39

KTP series double-transformer sub-station (single row of cabinets)

KTP series double-transformer sub-station (double row of cabinets)

*KTP series KSATO switchgears are ordered using data sheet.

Face

Page 40: Low voltage switchgears

LOW VOLTAGE SWITCHGEARS

www.abs-zeim.ru

4040

Com

plex

bus

es__

_A

Circ

uit b

reak

er

Curr

ent t

rans

form

er

Cabi

net t

ype

Hig

h vo

ltage

in

put

devi

ce

Pow

er

trans

form

erSH

VNN

inpu

t cab

inet

SHSN

N s

ectio

naliz

ing

cabi

net

SHLN

N li

near

cab

inet

SHVN

N in

put c

abin

etPo

wer

tra

nsfo

rmer

Hig

h vo

ltage

in

put

devi

ce

Cabi

net N

o1

23

4

Row

No

21

11

12

32

13

21

11

2

Feed

er N

oV1

12

34

SV5

67

89

1011

12V2

Vers

ion

(cab

le (K

) or

bus

duct

(SH

))SH

K↑K↑

K↑K↑

SHK↑

K↑K↑

K↑K↑

K↑K↑

K↑SH

Feed

er ra

ted

curr

ent,

A

Switc

h

Brea

ker

type

VA55

-43

VA51

-39

VA51

-39

VA51

-30

VA51

-39

VA55

-41

VA55

-41

VA06

-36

VA06

-36

VA06

-36

VA51

-39

VA51

-39

VA51

-39

VA51

-39

VA55

-41

Nom

inal

cu

rren

t, A

1600

630

630

630

630

1000

250

250

250

250

630

630

630

630

1600

Rele

aser

cu

rren

t, A

1600

630

630

630

630

1000

250

250

250

250

400

400

630

630

1600

Cata

logu

e No

3347

7034

4770

3447

7034

4770

3347

7034

1870

3418

7034

1870

3418

7034

1870

3447

7034

4770

3447

7034

4770

3347

70

Curr

ent t

rans

form

er,

trans

form

atio

n ty

pe

and

ratio

TSH

N-

0,66

15

00/5

TSH

N-

0,66

60

0/5

TSH

N-

0,66

60

0/5

TSH

N-

0,66

60

0/5

TSH

N-

0,66

60

0/5

TSH

N-

0,66

30

0/5

T-0,

66

300/

5T-

0,66

30

0/5

TSH

N-

0,66

30

0/5

T-0,

66

400/

5

TSH

N-

0,66

60

0/5

TSH

N-

0,66

60

0/5

TSH

N-

0,66

60

0/5

TSH

N-

0,66

15

00/5

Mea

surin

g de

vice

s

ZA07

04

curr

ent

met

er0-

1500

A0-

600A

0-60

0A0-

600A

0-60

0A-

0-30

0A0-

300A

0-30

0A0-

300A

0-40

0A0-

400A

0-60

0A0-

600A

0-15

00A

ZV07

04

volta

ge

met

er0-

500V

--

--

--

--

--

--

-0-

500V

Met

erSE

T-4T

M02

--

--

--

--

--

--

-SE

T4TM

020

Cust

omer

:Fa

cilit

y:

Auto

mat

ic tr

ansf

er

switc

h

Yes

Data

she

et fo

rm

Page 41: Low voltage switchgears

41

LOW VOLTAGE SWITCHGEARS

www.abs-zeim.ru

41

Water intake pump stations control cabinets

Major functions:

1. Monitoring of all the process parameters (water level, consumption, muddiness, temperature at the facility, pressure).2. State monitoring and pumps remote control.3. Transmission of alarm signals to the central control room.4. Maintaining set temperature regime at the facility.5. Receiving control signals from the central control room (pumps remote control).6. Indication of the following blockings triggering:• pump turning off at reaching set minimal level of

water in a well;• pump turning on in case of reaching set maximal

level of water in a well.7. Indication of the following types protection triggering:• thermal protection;• short circuit;• phase control.8. Pumps start/stop by commands formed on the basis of water level and pressure meters readings.9. Pumps performance control.10. Switching of pumps providing water to consumers in emergency mode (limited supply).

11. Water intake control either by means of a local terminal or by means of a terminal in the central control room.12. Data transfer via Ethernet, RS-232, RS-485, radio, GSM (ModBus).13. Local control panel installed on the front side of the cabinet allows local control and indication of process parameters.

Booster pump stations control cabinet

Major functions:

1. Keeping set pressure in incoming pipeline (if water tank is located above ground) or in a water tank (if it is located underground).2. Indication of the following types protection triggering:• thermal protection;• short circuit;• phase control;• phase interlacing;• dry run alarm;• backup pump start.3. Monitoring of all the process parameters (pressure before and after the pump, flow metering, temperature inside the cabinet, intrusion alarm).4. Routine submission of data to the central control room (pumps condition, pipeline pressure, flow rate, temperature at the facility).

5. Receiving control signals from the central control room (pumps remote control).6. Alarms signals transmission to the central control room.7. Maintaining set temperature regime at the facility.8. Implementation of the following blockings:• pump shut down in case of disruption of connection

to the central control room for more than 1 hour;• pump start in case of exceeding the set maximal

pressure value in the incoming pipeline.9. Data transfer via Ethernet, RS-232, RS-485, radio, GSM (ModBus).10. Local control panel installed on the front side of the cabinet allows local control and indication of process parameters.

Page 42: Low voltage switchgears

LOW VOLTAGE SWITCHGEARS

www.abs-zeim.ru

4242

Sewage pump stations control cabinets

Major functions:

1. Routine monitoring of the volume of sewage discharge.2. Automatic start of sewage pumping from a well based on the readings of transducers installed in the well.3. Remote and local control of equipment installed at a sewage pump station.4. Equipment state diagnostics. Maintaining temperature regime inside the room where a control cabinet is installed.5. Acquisition of readings from equipment installed at a sewage pump station and their transmission to an operator automated workstation in the central control room via radio or GSM (Modbus) channel.6. Optimization of pumps operational life utilization by means of their alternation, soft start, etc.7. Emergency situations prevention.8. Local control panel installed on the front side of the cabinet allows local control and indication of process parameters.

Water treatment facilities control cabinetsMajor functions:

1. Routine monitoring and logging of water purification quality.2. Metering and monitoring of the volume of purified water and the volume of water consumed for technical needs.3. Monitoring and control of water treatment facilities equipment.4. Monitored parameters logging in an easy for analysis form with a set records storage period.5. Coagulants and chemicals feed control depending on the volume of water to be treated.6. Water treatment facilities equipment washing control.7. Protection of actuators, check valves.8. Equipment diagnostics; monitoring and metering of treated water volume and water consumption for technical needs; automatic and remote switching of water treatment facilities operation modes.9. Fast data transfer to the central control room.10. Data transfer via Ethernet, RS-232, RS-485, radio, GSM (ModBus).

Page 43: Low voltage switchgears
Page 44: Low voltage switchgears

ABS Electro29, Serebryanicheskaya naberezhnaya, Moscow, Russian Federation, 109028Теl.: +7 (495) 735-42-44Fax.: +7 (495) 735-42-59E-mail: [email protected]

JSC «ABS Automation»1, I.Yakovleva ave., Cheboksary, Chuvash Republic, Russian Federation, 428020Теl.: +7 (8352) 30-51-48 Fаx.: +7 (8352) 30-51-11E-mail: [email protected]

www.abselectro.comwww.abs-zeim.ru

© A

BS E

lect

ro 08

.201

3 Pr

inte

d in

Rus

sia