low voltage power cable - hengtong group · 2016. 12. 2. · pt voksel eletric tbk. lv/hv...
TRANSCRIPT
2016 Version
Add.: No. 100 Hengtong Rd., Wujiang Economic
Development Zone , Suzhou , Jiangsu 215200 , China
Tel.: + 86-512 63956978
Fax.: + 86-512 63956979
E-mail: [email protected]
www.hengtonggroup.com
CREATE EXCELLENCE ADVOCATE CIVILIZATIONwww.hengtonggroup.com
CREATE A WORLD RENOWNED BRAND
BUILD AN INTERNATIONAL EXCELLENT ENTERPRISE
HTGDcorporation
HENGTONG OPTIC-ELECTRIC
HENGTONG OPTIC-ELECTRIC
LOW VOLTAGE POWER CABLEGlobal Information and Energy Network Service Provider
Global Information and
Energy Network Service Provider
www.hengtonggroup.com
HENGTONG OPTIC-ELECTRIC
CONTENT
HENGTONG OPTIC-ELECTRIC
Optical��Communication
Power��Transmission
EPC
Copper�Communication
HENGTONG OPTIC-ELECTRIC
HENGTONG OPTIC-ELECTRIC, a member of the HENGTONG
GROUP, is a global information and energy network service
provider focusing on high-end technology and products. It is
adapts to telecommunications and electricity trends and is
dedicated to optical communication, power distribution and
transmission, and a range of special transmission applications.
Connecting A Smarter Future19
Integrated solutions. A power, communications, and new energy provider.
CU/XLPE/PVC
CU/XLPE/PVC/AWA/PVC
CU/XLPE/PVC/SWA/PVC
AL/XLPE/PVC
AL/XLPE/PVC/AWA/PVC
AL/XLPE/PVC/SWA/PVC
CU/PVC/PVC
CU/PVC/PVC/AWA/PVC
CU/PVC/PVC/SWA/PVC
AL/PVC/PVC
AL/PVC/PVC/AWA/PVC
AL/PVC/PVC/SWA/PVC
Recommended Multi Core Identification
Maximum D.C. resistances of conductor at 20℃
Rating Factors
Current-carrying Capacities
07
10
11
13
16
17
22
23
25
28
29
31
32
33
35
�Application Areas
Global Partners
02Low Voltage Power Cable01 Low Voltage Power Cable
HENGTONG OVERVIEW HENGTONG OVERVIEW
Business Units
China's top 500
enterprises
(279th, 2016)
50 subsidiary
companies, 14,000
staff(2015)
Annual turnover
USD 7.2 billion
(2015)
The world's second
largest cable
manufacturer
(CRU 2014)
Founded in 1991,
IPO in 2003,
Stock code:
SH.600487
Optical CommunicationPreform-optic fiber-optical fiber cables-ODN (Capacity: 60 million fkm/year), Submarine optic
cables.
Power Transmission From Low-Voltage to High-Voltage, EHV (up to 500KV ), Submarine power cables,High-speed
railway contact wires, OPGW.
Copper CommunicationsRailway signal cables, Balise cables, Axle counting cables, Lan cables.
Raw Material for Wires and Cables
Provider of integrated power, communications, and new energy solutions
0403
INDONESIA
SOUTH AFRICA
BRAZIL
PORTUGAL
SPAIN
Industry Locations
United Arab Emirates
Jordan
Iran
Egypt
Algeria
Kenya
Nigeria
South Africa
Mozambique
Ethiopia
Congo
Ghana
Sudan
Zambia
Columbia
Chile
Brazil
Sales & technical service institution
Peru
Thailand
Myanmar
Vietnam
Indonesia
Cambodia
Philippines
Malaysia
Sri_Lanka
Taiwan
Australia
Pakistan
India
Russia
Turkey
Poland
Ecuador
HT Cabos E Tecnologia Ltda
Optical fiber cables
BRAZIL
Cables De Comunicaciones Zaragoza,s.l
Optical fiber / Data cables / Digital signal
cable for railway
SPAIN
Alcobre - Condutores Eléctricos, S.a.
Telecommunication cables /LV power cables/
Digital signal cable for railway
PORTUGAL
Aberdare Cable Proprietary Limited
LV/MV/HV power cables /
Overhead bare conductors
SOURTH AFRICA
Pt Voksel Eletric Tbk.
LV/HV Power�cable/Copper communication
cables /Optic fiber/OPGW
INDONESIA
Hengtong Optic-electric Co.,ltd.
All series communication and power
transmission products
B D
CHINA
Sales&service Institutions
34
Operating In 120 Countries
120
5 Brands
Overseas Manufacturing Bases
9
Low Voltage Power CableLow Voltage Power Cable
COMPANY INTRODUCTION
0605
Our company is equipped with national advanced equipment
like Finland NOKIA XLPE production line, German TRPESTER
rubber extruding production line, Italy continuus-properzi
aluminum and aluminum alloy CCR production line, America
Southwire copper CCR production line and America HIPO
partial discharge testing system and so on. We are the first
company among the same industry field that introduce the
various systems like OA, SAP, MES, CRM, SRM and other
information management system, 6S, 6SIGMA, ISO9001,
ISO14001, OHSAS18001,CNAS and other management
systems, using international advanced standards like IEC、EN、
AS/NZS、ASTM、ICEA、BS、NBR、NF、SANS、DNV and so
on, implement “whole faculty, whole process, whole
performance” as our quality control system.
We mainly supply of MV & LV power cable, Control cable,
Instrument cable, Aerial bundled cable, Optical fiber composite
MV & LV power cable, Solar cable, Wind power cable, Electric
Vehicle charging cable, Supper flexible anti-fire cable, Oil-
platform cable, Shipboard cable, Mining cable, Copper bare
conductor etc. series cable and solutions.
Since the foundation of our company, we have established
school-enterprise personnel and technical cooperation
agreement with Xi’an Jiaotong University, Shanghai Jiaotong
University and Harbin University of Science and Technology
and other universities nationwide and kept introducing all
kinds of excellent talented people and advanced technology.
Relying on the five innovation platforms and the advantage of
owing 6 provincial research centers, Hengtong actively
commits to the development and use of core intellectual
property to achieve breakthroughs in core technologies.
Jiangsu Hengtong Power Cable Co., Ltd is one of the national key high and new technology enterprises owned by Hengtong Group. We successfully listed on Shanghai Stock Exchange in 2003 with registered trademark: Hengtong Optic-electric (Stock Code: 600487).
Hengtong currently has 109 patents, including 22
invention patents. In addition, the company develops
more than five new products every year as a technical
reserve or launched into the market. In recent three years,
Hengtong has developed smart grids of OPLC, aluminum
cables, rated voltage of 0.6/1kV and below ceramic
silicone rubber fire-proof power cable, rated voltage of
35kV and below twist resistant soft cable for wind turbine,
photovoltaic cable, reel cable, medium voltage twist
resistant cable for wind turbine, environmental-friendly
anti-termite power cable, LSOH(halogen free) cables for
coal mines rubber sheathed soft cables, special wires and
other products. In the new products developed these
years, many of them have been rated to have a leading
position in China and has an international advanced level.
Some of the new products are initiative in China.
With its excellent technology, quality and service,
Hengtong’s products are widely applied into more than
10 industrial fields like the power, information,
transportation, metallurgy, petroleum and petrochemical,
coal, infrastructure, military industry, shipbuilding, marine
engineering equipment and clean energy fields and a lot
of large projects. Hengtong’s products have been
exported to 120 countries, gaining widely recognized and
global reputation and keep advancing to the in-depth of
the international market.
Low Voltage Power CableLow Voltage Power Cable
CU/XLPE/PVC
Single core XLPE insulatedcables with copper conductor
Standard: IEC 60502.1
Rated voltage: 0.6/1(1.2)kV
Test voltage: 3.5kV/5mins
Max. Short-circuit temperature: 250℃
Operating conductor temperature: 90℃
Min. temperature for laying and manipulation with cables: -5
Temperature range for operating: from -35 to +90
Colour of insulation: Natural
Colour of sheath: Black
Min. bending radius: 20 OD
Packing: Cable Drum
Optional
The cable design based on AS/NZS, SANS, NBR, ICEA, BS, EN, AEIC etc. is also available. Flame retardant, Fire resistant, Low smoke & Halogen free, Cold resistant, UV resistant, Oil resistant, Anti-rodent, Anti-termite, water proof is also available.
Application
For fixed installation, indoors and outdoors, in the ground and in concrete. The cables are resistant to UV radiation and to flame propagation according to IEC 60332.
0807
No. Cores &Cross section area
Approx. diameter of conductor
Product Parameter
Max. AC resistance
of conductor
at 90ºC
Max. diameter of cable
Approx. mass of cable
Max. DC resistance of conductor
at 20ºC
Fault current carrying of
conductor (1s)
Max. allowable pulling force of conductor
mm mm kNΩ/km
1.53
1.98
2.49
3.06
4.05
5.1
6.0
7.0
7.9
8.4
8.9
9.5
10.5
11.5
12.8
13.8
1x1.5
1x2.5
1x4
1x6
1x10
1x16
1x25
1x35
47
60
77
99
144
206
302
397
12.1
7.41
4.61
3.08
1.83
1.15
0.727
0.524
15.4
9.45
5.88
3.93
2.33
1.47
0.927
0.668
0.26
0.41
0.64
0.94
1.53
2.29
3.58
5.01
0.10
0.17
0.27
0.41
0.68
1.09
1.70
2.38
kg/km Ω/km kA
8.1
9.8
11.4
12.9
14.4
16.0
18.4
20.6
23.4
26.2
29.8
15.1
17.1
18.8
20.6
22.6
24.8
27.5
30.1
33.5
37.0
41.2
1x50
1x70
1x95
1x120
1x150
1x185
1x240
1x300
1x400
1x500
1x630
521
730
985
1229
1511
1878
2438
3030
3854
4910
6307
0.387
0.268
0.193
0.153
0.124
0.0991
0.0754
0.0601
0.0470
0.0366
0.0283
0.494
0.342
0.247
0.196
0.160
0.128
0.0989
0.0802
0.0644
0.0522
0.0430
7.15
10.02
13.59
17.17
21.46
26.47
34.34
42.93
57.23
71.54
90.14
3.40
4.76
6.46
8.16
10.20
12.58
16.32
20.40
27.20
34.00
42.84
Copper conductor
XLPE insulation
PVC sheath
CU/XLPE/PVC
Multi core XLPE insulated cables with copper conductor
Standard: IEC 60502.1
Rated voltage: 0.6/1(1.2)kV
Test voltage: 3.5kV/5mins
Max. Short-circuit temperature: 250℃
Operating conductor temperature: 90℃
Min. temperature for laying and manipulation with cables: -5℃
Temperature range for operating: from -35 to +90℃
Colour of insulation: Table 1
Colour of sheath: Black
Min. bending radius: 15 OD
Packing: Cable Drum
Optional
The cable design based on AS/NZS, SANS, NBR, ICEA, BS, EN, AEIC etc. is also available. Flame retardant, Fire resistant, Low smoke & Halogen free, Cold resistant, UV resistant, Oil resistant, Anti-rodent, Anti-termite, water proof is also available.
Application
For fixed installation, indoors and outdoors, in the ground and in concrete. The cables are resistant to UV radiation and to flame propagation according to IEC 60332.
No. Cores &Cross section area
Approx. diameter of conductor
Product Parameter
Max. AC resistance
of conductor
at 90ºC
Max. diameter of cable
Approx. mass of cable
Max. DC resistance of conductor
at 20ºC
Fault current carrying of
conductor (1s)
Max. allowable pulling force of conductor
mm mm kNΩ/km
1.53
1.98
2.49
3.06
4.05
5.1
6.0
7.0
8.1
9.8
11.4
12.9
14.4
16.0
18.4
20.6
23.4
1.53
1.98
12.2
13.1
14.1
15.3
17.3
19.4
22.0
24.0
26.6
30.5
33.9
37.5
41.6
46.0
51.8
57.2
64.4
12.7
13.7
117
146
186
236
340
478
693
902
1176
1639
2198
2746
3382
4202
5446
6761
8606
138
177
12.1
7.41
4.61
3.08
1.83
1.15
0.727
0.524
0.387
0.268
0.193
0.153
0.124
0.0991
0.0754
0.0601
0.0470
12.1
7.41
15.4
9.45
5.88
3.93
2.33
1.47
0.927
0.669
0.494
0.343
0.247
0.197
0.160
0.129
0.0996
0.0810
0.0654
15.4
9.45
0.26
0.41
0.64
0.94
1.53
2.29
3.58
5.01
7.15
10.02
13.59
17.17
21.46
26.47
34.34
42.93
57.23
0.26
0.41
0.20
0.34
0.54
0.82
1.36
2.18
3.40
4.76
6.80
9.52
12.92
16.32
20.40
25.16
32.64
40.80
54.40
0.31
0.51
kg/km Ω/km kA
2x1.5
2x2.5
2x4
2x6
2x10
2x16
2x25
2x35
2x50
2x70
2x95
2x120
2x150
2x185
2x240
2x300
2x400
3x1.5
3x2.5
Copper conductor
XLPE insulation
Filler
Binder tape
PVC sheath
Low Voltage Power CableLow Voltage Power Cable
No. Cores &Cross section area
Approx. diameter of conductor
Product Parameter
Max. AC resistance
of conductor
at 90ºC
Max. diameter of cable
Approx. mass of cable
Max. DC resistance of conductor
at 20ºC
Fault current carrying of
conductor (1s)
Max. allowable pulling force of conductor
mm mm kNΩ/km
2.49
3.06
4.05
5.1
6.0
7.0
8.1
9.8
11.4
12.9
14.4
16.0
18.4
20.6
23.4
1.53
1.98
2.49
3.06
4.05
5.1
6.0
7.0
8.1
9.8
11.4
12.9
14.4
16.0
18.4
20.6
23.4
1.53
1.98
2.49
3.06
4.05
5.1
6.0
7.0
8.1
9.8
11.4
12.9
14.4
16.0
18.4
20.6
23.4
14.8
16.0
18.2
20.4
23.2
25.4
28.2
32.6
36.2
40.2
44.7
49.5
55.8
61.6
69.4
13.5
14.6
15.9
17.2
19.6
22.2
25.3
27.7
31.1
35.9
40.1
44.6
49.7
55.2
62.2
68.7
77.4
14.4
15.6
17.0
18.5
21.2
24.1
27.6
30.4
34.1
39.6
44.3
49.4
55.2
61.2
69.1
76.3
86.1
231
301
444
637
939
1237
1625
2290
3089
3867
4766
5932
7708
9588
12217
165
214
284
373
559
810
1205
1596
2116
2989
4043
5065
6248
7782
10123
12600
16062
192
252
339
449
678
988
1479
1970
2623
3710
5024
6298
7771
9685
12603
15694
20013
4.61
3.08
1.83
1.15
0.727
0.524
0.387
0.268
0.193
0.153
0.124
0.0991
0.0754
0.0601
0.0470
12.1
7.41
4.61
3.08
1.83
1.15
0.727
0.524
0.387
0.268
0.193
0.153
0.124
0.0991
0.0754
0.0601
0.0470
12.1
7.41
4.61
3.08
1.83
1.15
0.727
0.524
0.387
0.268
0.193
0.153
0.124
0.0991
0.0754
0.0601
0.0470
5.88
3.93
2.33
1.47
0.927
0.669
0.494
0.343
0.247
0.197
0.160
0.129
0.0996
0.081
0.0654
15.4
9.45
5.88
3.93
2.33
1.47
0.927
0.669
0.494
0.343
0.247
0.197
0.160
0.129
0.0996
0.081
0.0654
15.4
9.45
5.88
3.93
2.33
1.47
0.927
0.669
0.494
0.343
0.247
0.197
0.160
0.129
0.0996
0.081
0.0654
0.64
0.94
1.53
2.29
3.58
5.01
7.15
10.02
13.59
17.17
21.46
26.47
34.34
42.93
57.23
0.26
0.41
0.64
0.94
1.53
2.29
3.58
5.01
7.15
10.02
13.59
17.17
21.46
26.47
34.34
42.93
57.23
0.26
0.41
0.64
0.94
1.53
2.29
3.58
5.01
7.15
10.02
13.59
17.17
21.46
26.47
34.34
42.93
57.23
0.82
1.22
2.04
3.26
5.10
7.14
10.20
14.28
19.38
24.48
30.60
37.74
48.96
61.20
81.60
0.41
0.68
1.09
1.63
2.72
4.35
6.80
9.52
13.60
19.04
25.84
32.64
40.80
50.32
65.28
81.60
108.80
0.51
0.85
1.36
2.04
3.40
5.44
8.50
11.90
17.00
23.80
32.30
40.80
51.00
62.90
81.60
102.00
136.00
kg/km Ω/km kA
3x4
3x6
3x10
3x16
3x25
3x35
3x50
3x70
3x95
3x120
3x150
3x185
3x240
3x300
3x400
4x1.5
4x2.5
4x4
4x6
4x10
4x16
4x25
4x35
4x50
4x70
4x95
4x120
4x150
4x185
4x240
4x300
4x400
5x1.5
5x2.5
5x4
5x6
5x10
5x16
5x25
5x35
5x50
5x70
5x95
5x120
5x150
5x185
5x240
5x300
5x400
CU/XLPE/PVC/AWA/PVC
Single core XLPE Insulated cables with copper conductor and aluminium wires armour
Standard: IEC 60502.1
Rated voltage: 0.6/1(1.2)kV
Test voltage: 3.5kV/5mins
Max. Short-circuit temperature: 250℃
Operating conductor temperature: 90℃
Min. temperature for laying and manipulation with cables: -5℃
Temperature range for operating: from -35 to +90℃
Colour of insulation: Natural
Colour of sheath: Black
Min. bending radius: 15 OD
Packing: Cable Drum
Optional
The cable design based on AS/NZS, SANS, NBR, ICEA, BS, EN, AEIC etc. is also available. Flame retardant, Fire resistant, Low smoke & Halogen free, Cold resistant, UV resistant, Oil resistant, Anti-rodent, Anti-termite, water proof is also available.
Application
For fixed installation, indoors and outdoors, in the ground and in concrete with higher risk of mechanical damage. The cables are resistant to UV radiation and to flame propagation according to IEC 60332.
No. Cores &Cross section area
Approx. diameter of conductor
Product Parameter
Max. AC resistance
of conductor
at 90ºC
Max. diameter of cable
Approx. mass of cable
Max. DC resistance of conductor
at 20ºC
Fault current carrying of
conductor (1s)
Max. allowable pulling force of conductor
mm mm kNΩ/km
1.53
1.98
2.49
3.06
4.05
5.1
6.0
7.0
8.1
9.8
11.4
12.9
14.4
16.0
18.4
20.6
23.4
26.2
29.8
13.2
13.6
14.1
14.7
15.7
16.7
18.0
19.0
21.2
23.1
24.7
27.1
29.0
31.0
33.8
36.4
41.1
44.6
49.1
1x1.5
1x2.5
1x4
1x6
1x10
1x16
1x25
1x35
1x50
1x70
1x95
1x120
1x150
1x185
1x240
1x300
1x400
1x500
1x630
153
172
196
226
285
359
474
583
767
1007
1284
1599
1906
2303
2913
3547
4563
5684
7171
12.1
7.41
4.61
3.08
1.83
1.15
0.727
0.524
0.387
0.268
0.193
0.153
0.124
0.0991
0.0754
0.0601
0.0470
0.0366
0.0283
15.4
9.45
5.88
3.93
2.33
1.47
0.927
0.668
0.494
0.342
0.247
0.196
0.159
0.128
0.0982
0.0793
0.0633
0.051
0.0415
0.26
0.41
0.64
0.94
1.53
2.29
3.58
5.01
7.15
10.02
13.59
17.17
21.46
26.47
34.34
42.93
57.23
71.54
90.14
0.35
0.39
0.43
0.47
0.55
0.61
0.71
0.78
1.34
1.58
1.77
2.51
2.74
3.06
3.45
3.76
5.39
5.88
6.62
kg/km Ω/km kA
Copper conductor
XLPE insulation
PVC inner sheath
Hard-drawn aluminium wires
Binder tape
PVC outer sheath
1009 Low Voltage Power CableLow Voltage Power Cable
CU/XLPE/PVC/SWA/PVC
Multi core XLPE Insulated cables with copper conductor and steel wires armour
Standard: IEC 60502.1
Rated voltage: 0.6/1(1.2)kV
Test voltage: 3.5kV/5mins
Max. Short-circuit temperature: 250℃
Operating conductor temperature: 90℃
Min. temperature for laying and manipulation with cables: -5℃
Temperature range for operating: from -35 to +90℃
Colour of insulation: Table 1
Colour of sheath: Black
Min. bending radius: 120D
Packing: Cable Drum
Optional
The cable design based on AS/NZS, SANS, NBR, ICEA, BS, EN, AEIC etc. is also available. Flame retardant, Fire resistant, Low smoke & Halogen free, Cold resistant, UV resistant, Oil resistant, Anti-rodent, Anti-termite, water proof is also available.
Application
For fixed installation, indoors and outdoors, in the ground and in concrete with higher risk of mechanical damage. The cables are resistant to UV radiation and to flame propagation according to IEC 60332.
No. Cores &Cross section area
Approx. diameter of conductor
Product Parameter
Max. AC resistance
of conductor
at 90ºC
Max. diameter of cable
Approx. mass of cable
Max. DC resistance of conductor
at 20ºC
Fault current carrying of
conductor (1s)
Max. allowable pulling force of conductor
mm mm kNΩ/km
1.53
1.98
2.49
3.06
4.05
5.1
6.0
7.0
8.1
9.8
11.4
12.9
14.4
16.0
18.4
20.6
23.4
1.53
1.98
16.7
17.6
18.6
19.7
22.6
24.7
28.0
30.0
32.7
36.7
41.4
45.2
49.4
55.5
61.3
67.1
74.3
17.2
18.1
2x1.5
2x2.5
2x4
2x6
2x10
2x16
2x25
2x35
2x50
2x70
2x95
2x120
2x150
2x185
2x240
2x300
2x400
3x1.5
3x2.5
337
384
447
522
799
1002
1415
1704
2085
2702
3663
4373
5201
6686
8231
9893
12141
370
431
12.1
7.41
4.61
3.08
1.83
1.15
0.727
0.524
0.387
0.268
0.193
0.153
0.124
0.0991
0.0754
0.0601
0.0470
12.1
7.41
15.4
9.45
5.88
3.93
2.33
1.47
0.927
0.669
0.494
0.343
0.247
0.197
0.160
0.129
0.0996
0.081
0.0654
15.4
9.45
0.26
0.41
0.64
0.94
1.53
2.29
3.58
5.01
7.15
10.02
13.59
17.17
21.46
26.47
34.34
42.93
57.23
0.26
0.41
1.64
1.79
2.01
2.22
4.12
4.77
6.97
7.81
8.87
10.34
14.51
16.16
18.14
25.26
28.35
31.44
35.56
1.74
1.95
kg/km Ω/km kA
No. Cores &Cross section area
Approx. diameter of conductor
Product Parameter
Max. AC resistance
of conductor
at 90ºC
Max. diameter of cable
Approx. mass of cable
Max. DC resistance of conductor
at 20ºC
Fault current carrying of
conductor (1s)
Max. allowable pulling force of conductor
mm mm kNΩ/km kg/km Ω/km kA
Copper conductor
XLPE insulation
Filler
Binder tape
PVC inner sheath
Galvanized steel wires
Binder tape
PVC outer sheath
2.49
3.06
4.05
5.1
6.0
7.0
8.1
9.8
11.4
12.9
14.4
16.0
18.4
20.6
23.4
1.53
1.98
2.49
3.06
4.05
5.1
6.0
7.0
8.1
9.8
11.4
12.9
14.4
16.0
18.4
20.6
23.4
1.53
1.98
2.49
3.06
4.05
5.1
6.0
7.0
8.1
9.8
11.4
12.9
14.4
16.0
18.4
20.6
23.4
19.2
21.4
23.5
25.8
29.3
31.4
34.5
40.1
43.9
48.0
54.1
58.9
65.6
71.4
79.2
18.0
19.1
21.2
22.6
25.0
28.2
31.4
33.9
38.2
43.5
47.9
54.0
59.2
64.6
72.0
78.5
89.2
18.9
20.1
22.3
23.9
26.6
30.1
33.7
36.6
41.7
47.3
53.7
58.9
64.6
71.1
78.9
88.1
97.8
510
721
929
1187
1719
2098
2603
3691
4653
5621
7157
8572
10745
12969
16006
414
487
693
832
1084
1549
2049
2550
3423
4550
5796
7455
8931
10720
13511
16340
21241
460
549
786
946
1254
1790
2412
3015
4090
5433
7411
8937
10709
13023
16348
20859
25810
4.61
3.08
1.83
1.15
0.727
0.524
0.387
0.268
0.193
0.153
0.124
0.0991
0.0754
0.0601
0.0470
12.1
7.41
4.61
3.08
1.83
1.15
0.727
0.524
0.387
0.268
0.193
0.153
0.124
0.0991
0.0754
0.0601
0.0470
12.1
7.41
4.61
3.08
1.83
1.15
0.727
0.524
0.387
0.268
0.193
0.153
0.124
0.0991
0.0754
0.0601
0.0470
5.88
3.93
2.33
1.47
0.927
0.669
0.494
0.343
0.247
0.197
0.160
0.129
0.0996
0.081
0.0654
15.4
9.45
5.88
3.93
2.33
1.47
0.927
0.669
0.494
0.343
0.247
0.197
0.160
0.129
0.0996
0.081
0.0654
15.4
9.45
5.88
3.93
2.33
1.47
0.927
0.669
0.494
0.343
0.247
0.197
0.160
0.129
0.0996
0.081
0.0654
0.64
0.94
1.53
2.29
3.58
5.01
7.15
10.02
13.59
17.17
21.46
26.47
34.34
42.93
57.23
0.26
0.41
0.64
0.94
1.53
2.29
3.58
5.01
7.15
10.02
13.59
17.17
21.46
26.47
34.34
42.93
57.23
0.26
0.41
0.64
0.94
1.53
2.29
3.58
5.01
7.15
10.02
13.59
17.17
21.46
26.47
34.34
42.93
57.23
2.16
3.74
4.38
5.03
7.60
8.44
9.50
13.85
15.50
17.48
24.22
26.80
30.41
34.02
38.14
1.90
2.11
3.61
4.12
4.77
7.18
8.23
9.29
13.19
15.50
17.48
24.22
27.32
29.89
34.02
37.63
53.19
2.06
2.32
3.99
4.51
5.28
7.81
9.08
10.13
14.51
17.15
24.22
26.80
29.89
33.50
37.63
53.19
59.73
3x4
3x6
3x10
3x16
3x25
3x35
3x50
3x70
3x95
3x120
3x150
3x185
3x240
3x300
3x400
4x1.5
4x2.5
4x4
4x6
4x10
4x16
4x25
4x35
4x50
4x70
4x95
4x120
4x150
4x185
4x240
4x300
4x400
5x1.5
5x2.5
5x4
5x6
5x10
5x16
5x25
5x35
5x50
5x70
5x95
5x120
5x150
5x185
5x240
5x300
5x400
1211 Low Voltage Power CableLow Voltage Power Cable
AL/XLPE/PVC
Single core XLPE insulated cables withaluminium conductor
Standard: IEC 60502.1
Rated voltage: 0.6/1(1.2)kV
Test voltage: 3.5kV/5mins
Max. Short-circuit temperature: 250℃
Operating conductor temperature: 90℃
Min. temperature for laying and manipulation with cables: -5℃
Temperature range for operating: from -35 to +90℃
Colour of insulation: Natural
Colour of sheath: Black
Min. bending radius: 20 OD
Packing: Cable Drum
Optional
The cable design based on AS/NZS, SANS, NBR, ICEA, BS, EN, AEIC etc. is also available. Flame retardant, Fire resistant, Low smoke & Halogen free, Cold resistant, UV resistant, Oil resistant, Anti-rodent, Anti-termite, water proof is also available.
Application
For fixed installation, indoors and outdoors, in the ground and in concrete. The cables are resistant to UV radiation and to flame propagation according to IEC 60332.
No. Cores &Cross section area
Approx. diameter of conductor
Product Parameter
Max. AC resistance
of conductor
at 90ºC
Max. diameter of cable
Approx. mass of cable
Max. DC resistance of conductor
at 20ºC
Fault current carrying of
conductor (1s)
Max. allowable pulling force of conductor
mm mm kNΩ/km kg/km Ω/km kA
Aluminium conductor
XLPE insulation
PVC sheath
3.99
5.07
6.0
7.0
8.1
9.8
11.4
12.9
14.4
16.0
18.4
20.6
23.4
26.2
29.8
10.4
11.5
12.8
13.8
15.1
17.1
18.8
20.6
22.6
24.8
27.5
30.1
33.5
37.0
41.2
1x10
1x16
1x25
1x35
1x50
1x70
1x95
1x120
1x150
1x185
1x240
1x300
1x400
1x500
1x630
82
107
147
181
228
308
398
490
597
736
936
1143
1447
1820
2307
3.08
1.91
1.20
0.868
0.641
0.443
0.320
0.253
0.206
0.164
0.125
0.100
0.0778
0.0605
0.0469
3.95
2.45
1.54
1.11
0.822
0.568
0.411
0.325
0.265
0.212
0.162
0.130
0.103
0.0812
0.0647
1.03
1.51
2.36
3.31
4.72
6.61
8.98
11.34
14.17
17.48
22.68
28.35
37.79
47.24
59.52
0.39
0.62
0.98
1.37
1.95
2.73
3.71
4.68
5.85
7.22
9.36
11.70
15.60
19.50
24.57
AL/XLPE/PVC
Multi core XLPE insulated cables with aluminium conductor
Standard: IEC 60502.1
Rated voltage: 0.6/1(1.2)kV
Test voltage: 3.5kV/5mins
Max. Short-circuit temperature: 250℃
Operating conductor temperature: 90℃
Min. temperature for laying and manipulation with cables: -5℃
Temperature range for operating: from -35 to +90℃
Colour of insulation: Table 1
Colour of sheath: Black
Min. bending radius: 15 OD
Packing: Cable Drum
Optional
The cable design based on AS/NZS, SANS, NBR, ICEA, BS, EN, AEIC etc. is also available. Flame retardant, Fire resistant, Low smoke & Halogen free, Cold resistant, UV resistant, Oil resistant, Anti-rodent, Anti-termite, water proof is also available.
Application
For fixed installation, indoors and outdoors, in the ground and in concrete. The cables are resistant to UV radiation and to flame propagation according to IEC 60332.
No. Cores &Cross section area
Approx. diameter of conductor
Product Parameter
Max. AC resistance
of conductor
at 90ºC
Max. diameter of cable
Approx. mass of cable
Max. DC resistance of conductor
at 20ºC
Fault current carrying of
conductor (1s)
Max. allowable pulling force of conductor
mm mm kNΩ/km
3.99
5.07
6.0
7.0
8.1
9.8
11.4
12.9
14.4
16.0
18.4
20.6
23.4
3.99
5.07
6.0
7.0
8.1
9.8
17.1
19.3
22.0
24.0
26.6
30.5
33.9
37.5
41.6
46.0
51.8
57.2
64.4
18.0
20.4
23.2
25.4
28.2
32.6
2x10
2x16
2x25
2x35
2x50
2x70
2x95
2x120
2x150
2x185
2x240
2x300
2x400
3x10
3x16
3x25
3x35
3x50
3x70
213
279
381
468
588
792
1019
1261
1546
1908
2429
2970
3770
254
338
471
586
743
1018
3.08
1.91
1.20
0.868
0.641
0.443
0.320
0.253
0.206
0.164
0.125
0.100
0.0778
3.08
1.91
1.20
0.868
0.641
0.443
3.95
2.45
1.54
1.11
0.822
0.569
0.411
0.325
0.265
0.212
0.162
0.131
0.103
3.95
2.45
1.54
1.11
0.822
0.569
1.03
1.51
2.36
3.31
4.72
6.61
8.98
11.34
14.17
17.48
22.68
28.35
37.79
1.03
1.51
2.36
3.31
4.72
6.61
0.78
1.25
1.95
2.73
3.90
5.46
7.41
9.36
11.70
14.43
18.72
23.40
31.20
1.17
1.87
2.93
4.10
5.85
8.19
kg/km Ω/km kA
Aluminium conductor
XLPE insulation
Filler
Binder tape
PVC sheath
1413 Low Voltage Power CableLow Voltage Power Cable
No. Cores &Cross section area
Approx. diameter of conductor
Max. AC resistance
of conductor
at 90ºC
Max. diameter of cable
Approx. mass of cable
Max. DC resistance of conductor
at 20ºC
Fault current carrying of
conductor (1s)
Max. allowable pulling force of conductor
mm mm kNΩ/km
11.4
12.9
14.4
16.0
18.4
20.6
23.4
3.99
5.07
6.0
7.0
8.1
9.8
11.4
12.9
14.4
16.0
18.4
20.6
23.4
3.99
5.07
6.0
7.0
8.1
9.8
11.4
12.9
14.4
16.0
18.4
20.6
23.4
36.2
40.2
44.7
49.5
55.8
61.6
69.4
19.5
22.1
25.3
27.7
31.1
35.9
40.1
44.6
49.7
55.2
62.2
68.7
77.4
21.1
24.0
27.6
30.4
34.1
39.6
44.3
49.4
55.2
61.2
69.1
76.3
86.1
3x95
3x120
3x150
3x185
3x240
3x300
3x400
4x10
4x16
4x25
4x35
4x50
4x70
4x95
4x120
4x150
4x185
4x240
4x300
4x400
5x10
5x16
5x25
5x35
5x50
5x70
5x95
5x120
5x150
5x185
5x240
5x300
5x400
1321
1639
2012
2492
3182
3901
4962
306
412
580
728
941
1294
1685
2095
2575
3195
4089
5018
6389
362
492
698
885
1154
1591
2077
2585
3181
3950
5060
6217
7921
0.320
0.253
0.206
0.164
0.125
0.100
0.0778
3.08
1.91
1.20
0.868
0.641
0.443
0.320
0.253
0.206
0.164
0.125
0.100
0.0778
3.08
1.91
1.20
0.868
0.641
0.443
0.320
0.253
0.206
0.164
0.125
0.100
0.0778
0.411
0.325
0.265
0.212
0.162
0.131
0.103
3.95
2.45
1.54
1.11
0.822
0.569
0.411
0.325
0.265
0.212
0.162
0.131
0.103
3.95
2.45
1.54
1.11
0.822
0.569
0.411
0.325
0.265
0.212
0.162
0.131
0.103
8.98
11.34
14.17
17.48
22.68
28.35
37.79
1.03
1.51
2.36
3.31
4.72
6.61
8.98
11.34
14.17
17.48
22.68
28.35
37.79
1.03
1.51
2.36
3.31
4.72
6.61
8.98
11.34
14.17
17.48
22.68
28.35
37.79
11.12
14.04
17.55
21.65
28.08
35.10
46.80
1.56
2.50
3.90
5.46
7.80
10.92
14.82
18.72
23.40
28.86
37.44
46.80
62.40
1.95
3.12
4.88
6.83
9.75
13.65
18.53
23.40
29.25
36.08
46.80
58.50
78.00
kg/km Ω/km kA
Product Parameter
AL/XLPE/PVC/AWA/PVC
Single core XLPE Insulated cables with aluminium conductor and aluminium wires armour
Standard: IEC 60502.1
Rated voltage: 0.6/1(1.2)kV
Test voltage: 3.5kV/5mins
Max. Short-circuit temperature: 250℃
Operating conductor temperature: 90℃
Min. temperature for laying and manipulation with cables: -5℃
Temperature range for operating: from -35 to +90℃
Colour of insulation: Natural
Colour of sheath: Black
Min. bending radius: 15 OD
Packing: Cable Drum
Optional
The cable design based on AS/NZS, SANS, NBR, ICEA, BS, EN, AEIC etc. is also available. Flame retardant, Fire resistant, Low smoke & Halogen free, Cold resistant, UV resistant, Oil resistant, Anti-rodent, Anti-termite, water proof is also available.
Application
For fixed installation, indoors and outdoors, in the ground and in concrete with higher risk of mechanical damage. The cables are resistant to UV radiation and to flame propagation according to IEC 60332.
No. Cores &Cross section area
Approx. diameter of conductor
Product Parameter
Max. AC resistance
of conductor
at 90ºC
Max. diameter of cable
Approx. mass of cable
Max. DC resistance of conductor
at 20ºC
Fault current carrying of
conductor (1s)
Max. allowable pulling force of conductor
mm mm kNΩ/km
3.99
5.07
6.0
7.0
8.1
9.8
11.4
12.9
14.4
16.0
18.4
20.6
23.4
26.2
29.8
15.6
16.7
18.0
19.0
21.2
23.1
24.7
27.1
29.0
31.0
33.8
36.4
41.1
44.6
49.1
1x10
1x16
1x25
1x35
1x50
1x70
1x95
1x120
1x150
1x185
1x240
1x300
1x400
1x500
1x630
220
260
318
367
475
585
697
859
992
1162
1411
1660
2156
2594
3171
3.08
1.91
1.20
0.868
0.641
0.443
0.320
0.253
0.206
0.164
0.125
0.100
0.0778
0.0605
0.0469
3.95
2.45
1.54
1.11
0.822
0.568
0.411
0.325
0.265
0.211
0.162
0.130
0.102
0.0803
0.0637
1.03
1.51
2.36
3.31
4.72
6.61
8.98
11.34
14.17
17.48
22.68
28.35
37.79
47.24
59.52
0.53
0.61
0.71
0.78
1.34
1.58
1.77
2.51
2.74
3.06
3.45
3.76
5.39
5.88
6.62
kg/km Ω/km kA
Aluminium conductor
XLPE insulation
PVC inner sheath
Hard-drawn aluminium wires
Binder tape
PVC outer sheath
1615 Low Voltage Power CableLow Voltage Power Cable
AL/XLPE/PVC/SWA/PVC
Multi core XLPE Insulated cables with aluminium conductor and steel wires armour
Standard: IEC 60502.1
Rated voltage: 0.6/1(1.2)kV
Test voltage: 3.5kV/5mins
Max. Short-circuit temperature: 250℃
Operating conductor temperature: 90℃
Min. temperature for laying and manipulation with cables: -5℃
Temperature range for operating: from -35 to +90℃
Colour of insulation: Table 1
Colour of sheath: Black
Min. bending radius: 120D
Packing: Cable Drum
Optional
The cable design based on AS/NZS, SANS, NBR, ICEA, BS, EN, AEIC etc. is also available. Flame retardant, Fire resistant, Low smoke & Halogen free, Cold resistant, UV resistant, Oil resistant, Anti-rodent, Anti-termite, water proof is also available.
Application
For fixed installation, indoors and outdoors, in the ground and in concrete with higher risk of mechanical damage. The cables are resistant to UV radiation and to flame propagation according to IEC 60332.
No. Cores &Cross section area
Approx. diameter of conductor
Product Parameter
Max. AC resistance
of conductor
at 90ºC
Max. diameter of cable
Approx. mass of cable
Max. DC resistance of conductor
at 20ºC
Fault current carrying of
conductor (1s)
Max. allowable pulling force of conductor
mm mm kNΩ/km
3.99
5.07
6.0
7.0
8.1
9.8
11.4
12.9
14.4
16.0
18.4
20.6
23.4
3.99
5.07
6.0
7.0
8.1
9.8
22.5
24.6
28.0
30.0
32.7
36.7
41.4
45.2
49.4
55.5
61.3
67.1
74.3
23.4
25.7
29.3
31.4
34.5
40.1
2x10
2x16
2x25
2x35
2x50
2x70
2x95
2x120
2x150
2x185
2x240
2x300
2x400
3x10
3x16
3x25
3x35
3x50
3x70
661
792
1102
1270
1498
1854
2484
2888
3365
4393
5214
6103
7304
728
889
1251
1447
1722
2419
3.08
1.91
1.20
0.868
0.641
0.443
0.320
0.253
0.206
0.164
0.125
0.100
0.0778
3.08
1.91
1.20
0.868
0.641
0.443
3.95
2.45
1.54
1.11
0.822
0.569
0.411
0.325
0.265
0.212
0.162
0.131
0.103
3.95
2.45
1.54
1.11
0.822
0.569
1.03
1.51
2.36
3.31
4.72
6.61
8.98
11.34
14.17
17.48
22.68
28.35
37.79
1.03
1.51
2.36
3.31
4.72
6.61
3.99
4.64
6.97
7.81
8.87
10.34
14.51
16.16
18.14
25.26
28.35
31.44
35.56
4.25
5.03
7.60
8.44
9.50
13.85
kg/km Ω/km kA
No. Cores &Cross section area
Approx. diameter of conductor
Max. AC resistance
of conductor
at 90ºC
Max. diameter of cable
Approx. mass of cable
Max. DC resistance of conductor
at 20ºC
Fault current carrying of
conductor (1s)
Max. allowable pulling force of conductor
mm mm kNΩ/km kg/km Ω/km kA
Product Parameter
43.9
48.0
54.1
58.9
65.6
71.4
79.2
24.8
28.1
31.4
33.9
38.2
43.5
47.9
54.0
59.2
64.6
72.0
78.5
89.2
26.4
30.0
33.7
36.6
41.7
47.3
53.7
58.9
64.6
71.1
78.9
88.1
97.8
2885
3393
4403
5132
6219
7283
8751
830
1135
1424
1682
2248
2855
3439
4484
5258
6133
7477
8758
11567
927
1293
1631
1930
2621
3314
4464
5224
6119
7288
8805
11382
13718
15.50
17.48
24.22
26.80
30.41
34.02
38.14
4.77
6.97
8.23
9.29
13.19
15.50
17.48
24.22
27.32
29.89
34.02
37.63
53.19
5.15
7.81
9.08
10.13
14.51
17.15
24.22
26.80
29.89
33.50
37.63
53.19
59.73
8.98
11.34
14.17
17.48
22.68
28.35
37.79
1.03
1.51
2.36
3.31
4.72
6.61
8.98
11.34
14.17
17.48
22.68
28.35
37.79
1.03
1.51
2.36
3.31
4.72
6.61
8.98
11.34
14.17
17.48
22.68
28.35
37.79
0.411
0.325
0.265
0.212
0.162
0.131
0.103
3.95
2.45
1.54
1.11
0.822
0.569
0.411
0.325
0.265
0.212
0.162
0.131
0.103
3.95
2.45
1.54
1.11
0.822
0.569
0.411
0.325
0.265
0.212
0.162
0.131
0.103
0.320
0.253
0.206
0.164
0.125
0.100
0.0778
3.08
1.91
1.20
0.868
0.641
0.443
0.320
0.253
0.206
0.164
0.125
0.100
0.0778
3.08
1.91
1.20
0.868
0.641
0.443
0.320
0.253
0.206
0.164
0.125
0.100
0.0778
11.4
12.9
14.4
16.0
18.4
20.6
23.4
3.99
5.07
6.0
7.0
8.1
9.8
11.4
12.9
14.4
16.0
18.4
20.6
23.4
3.99
5.07
6.0
7.0
8.1
9.8
11.4
12.9
14.4
16.0
18.4
20.6
23.4
3x95
3x120
3x150
3x185
3x240
3x300
3x400
4x10
4x16
4x25
4x35
4x50
4x70
4x95
4x120
4x150
4x185
4x240
4x300
4x400
5x10
5x16
5x25
5x35
5x50
5x70
5x95
5x120
5x150
5x185
5x240
5x300
5x400
Aluminium conductor
XLPE insulation
Filler
Binder tape
PVC inner sheath
Galvanized steel wires
Binder tape
PVC outer sheath
1817 Low Voltage Power CableLow Voltage Power Cable
CU/PVC/PVC
Single core PVC insulated cables with copper conductor
Standard: IEC 60502.1
Rated voltage: 0.6/1(1.2)kV
Test voltage: 3.5kV/5mins
Max. Short-circuit temperature: 160℃ (CSA≤300mm2), 140℃ (CSA>300mm2)
Operating conductor temperature: 70℃
Min. temperature for laying and manipulation with cables: -5℃
Temperature range for operating: from -35 to +70℃
Colour of insulation: White
Colour of sheath: Black
Min. bending radius: 20 OD
Packing: Cable Drum
Optional
The cable design based on AS/NZS, SANS, NBR, ICEA, BS, EN, AEIC etc. is also available. Flame retardant, Fire resistant, Low smoke & Halogen free, Cold resistant, UV resistant, Oil resistant, Anti-rodent, Anti-termite, water proof is also available.
Application
For fixed installation, indoors and outdoors, in the ground and in concrete. The cables are resistant to UV radiation and to flame propagation according to IEC 60332.
No. Cores &Cross section area
Approx. diameter of conductor
Product Parameter
Max. AC resistance
of conductor
at 90ºC
Max. diameter of cable
Approx. mass of cable
Max. DC resistance of conductor
at 20ºC
Fault current carrying of
conductor (1s)
Max. allowable pulling force of conductor
mm mm kNΩ/km
1.53
1.98
2.49
3.06
4.05
5.1
6.0
7.0
8.1
9.8
11.4
12.9
14.4
16.0
18.4
20.6
23.4
26.2
29.8
8.1
8.6
9.5
10.1
11.1
12.1
13.4
14.4
15.9
17.7
19.9
21.5
23.5
25.6
28.6
31.4
34.8
38.2
42.1
53
66
91
115
163
227
329
427
564
775
1052
1297
1592
1973
2562
3185
4038
5123
6519
12.1
7.41
4.61
3.08
1.83
1.15
0.727
0.524
0.387
0.268
0.193
0.153
0.124
0.0991
0.0754
0.0601
0.0470
0.0366
0.0283
14.5
8.87
5.52
3.69
2.19
1.38
0.870
0.627
0.463
0.321
0.232
0.184
0.150
0.121
0.0930
0.0754
0.0607
0.0494
0.0408
0.19
0.42
0.65
0.96
1.59
2.42
3.78
5.30
7.56
10.59
14.37
18.16
22.69
27.99
36.31
45.39
60.52
75.65
95.32
0.10
0.17
0.27
0.41
0.68
1.09
1.70
2.38
3.40
4.76
6.46
8.16
10.20
12.58
16.32
20.40
27.20
34.00
42.84
kg/km Ω/km kA
Copper conductor
PVC insulation
PVC sheath
1x1.5
1x2.5
1x4
1x6
1x10
1x16
1x25
1x35
1x50
1x70
1x95
1x120
1x150
1x185
1x240
1x300
1x400
1x500
1x630
CU/PVC/PVC
Multi core PVC insulated cables with copper conductor
Standard: IEC 60502.1
Rated voltage: 0.6/1(1.2)kV
Test voltage: 3.5kV/5mins
Max. Short-circuit temperature: 160℃ (CSA≤300mm2), 140℃ (CSA>300mm2)
Operating conductor temperature: 70℃
Min. temperature for laying and manipulation with cables: -5℃
Temperature range for operating: from -35 to +70℃
Colour of insulation: Table 1
Colour of sheath: Black
Min. bending radius: 15 OD
Packing: Cable Drum
Optional
The cable design based on AS/NZS, SANS, NBR, ICEA, BS, EN, AEIC etc. is also available. Flame retardant, Fire resistant, Low smoke & Low halogen, Cold resistant, UV resistant, Oil resistant, Anti-rodent, Anti-termite, water proof is also available.
Application
For fixed installation, indoors and outdoors, in the ground and in concrete. The cables are resistant to UV radiation and to flame propagation according to IEC 60332.
No. Cores &Cross section area
Approx. diameter of conductor
Product Parameter
Max. AC resistance
of conductor
at 90ºC
Max. diameter of cable
Approx. mass of cable
Max. DC resistance of conductor
at 20ºC
Fault current carrying of
conductor (1s)
Max. allowable pulling force of conductor
mm mm kNΩ/km
1.98
2.49
3.06
4.05
5.1
6.0
7.0
8.1
9.8
11.4
12.9
14.4
16.0
18.4
20.6
23.4
1.53
1.98
2.49
13.5
15.3
16.5
18.5
20.6
23.2
25.2
28.2
31.8
36.0
39.2
43.3
47.8
54.1
59.9
67.1
14.0
15.1
17.3
161
221
275
386
530
758
974
1276
1746
2366
2911
3577
4429
5746
7140
9051
188
240
342
7.41
4.61
3.08
1.83
1.15
0.727
0.524
0.387
0.268
0.193
0.153
0.124
0.0991
0.0754
0.0601
0.0470
12.1
7.41
4.61
8.87
5.52
3.69
2.19
1.38
0.870
0.627
0.464
0.322
0.232
0.185
0.150
0.121
0.0937
0.0762
0.0616
14.5
8.87
5.52
0.42
0.65
0.96
1.59
2.42
3.78
5.30
7.56
10.59
14.37
18.16
22.69
27.99
36.31
45.39
60.52
0.26
0.42
0.65
0.34
0.54
0.82
1.36
2.18
3.40
4.76
6.80
9.52
12.92
16.32
20.40
25.16
32.64
40.80
54.40
0.41
0.68
1.09
kg/km Ω/km kA
2x2.5
2x4
2x6
2x10
2x16
2x25
2x35
2x50
2x70
2x95
2x120
2x150
2x185
2x240
2x300
2x400
3x1.5
3x2.5
3x4
Copper conductor
PVC insulation
Filler
Binder tape
PVC sheath
2019 Low Voltage Power CableLow Voltage Power Cable
No. Cores &Cross section area
Approx. diameter of conductor
Product Parameter
Max. AC resistance
of conductor
at 90ºC
Max. diameter of cable
Approx. mass of cable
Max. DC resistance of conductor
at 20ºC
Fault current carrying of
conductor (1s)
Max. allowable pulling force of conductor
mm mm kNΩ/km
3.06
4.05
5.1
6.0
7.0
8.1
9.8
11.4
12.9
14.4
16.0
18.4
20.6
23.4
1.53
1.98
2.49
3.06
4.05
5.1
6.0
7.0
8.1
9.8
11.4
12.9
14.4
16.0
18.4
20.6
23.4
1.53
1.98
2.49
3.06
4.05
5.1
6.0
7.0
8.1
9.8
11.4
12.9
14.4
16.0
18.4
20.6
23.4
18.7
21.1
23.6
26.8
29.2
33.1
37.5
42.7
46.8
51.9
57.3
64.9
71.9
80.7
13.2
14.1
16.1
17.3
19.5
21.7
24.5
26.7
30.1
33.9
38.6
42.0
46.6
51.4
58.2
64.5
72.3
15.0
16.2
18.6
20.2
22.8
25.7
29.2
32.1
36.5
41.3
47.3
51.9
57.6
63.7
72.1
80.0
89.7
438
635
898
1318
1723
2301
3179
4337
5359
6596
8192
10660
13277
16860
157
198
277
352
504
706
1026
1334
1768
2436
3316
4092
5033
6246
8121
10107
12827
221
285
410
528
772
1097
1617
2133
2853
3946
5388
6662
8205
10195
13273
16537
21008
3.08
1.83
1.15
0.727
0.524
0.387
0.268
0.193
0.153
0.124
0.0991
0.0754
0.0601
0.0470
12.1
7.41
4.61
3.08
1.83
1.15
0.727
0.524
0.387
0.268
0.193
0.153
0.124
0.0991
0.0754
0.0601
0.0470
12.1
7.41
4.61
3.08
1.83
1.15
0.727
0.524
0.387
0.268
0.193
0.153
0.124
0.0991
0.0754
0.0601
0.0470
3.69
2.19
1.38
0.870
0.627
0.464
0.322
0.232
0.185
0.150
0.121
0.0937
0.0762
0.0616
14.5
8.87
5.52
3.69
2.19
1.38
0.870
0.627
0.464
0.322
0.232
0.185
0.150
0.121
0.0937
0.0762
0.0616
14.5
8.87
5.52
3.69
2.19
1.38
0.870
0.627
0.464
0.322
0.232
0.185
0.150
0.121
0.0937
0.0762
0.0616
0.96
1.59
2.42
3.78
5.30
7.56
10.59
14.37
18.16
22.69
27.99
36.31
45.39
60.52
0.26
0.42
0.65
0.96
1.59
2.42
3.78
5.30
7.56
10.59
14.37
18.16
22.69
27.99
36.31
45.39
60.52
0.26
0.42
0.65
0.96
1.59
2.42
3.78
5.30
7.56
10.59
14.37
18.16
22.69
27.99
36.31
45.39
60.52
1.63
2.72
4.35
6.80
9.52
13.60
19.04
25.84
32.64
40.80
50.32
65.28
81.60
108.80
0.31
0.51
0.82
1.22
2.04
3.26
5.10
7.14
10.20
14.28
19.38
24.48
30.60
37.74
48.96
61.20
81.60
0.51
0.85
1.36
2.04
3.40
5.44
8.50
11.90
17.00
23.80
32.30
40.80
51.00
62.90
81.60
102.00
136.00
kg/km Ω/km kA
3x6
3x10
3x16
3x25
3x35
3x50
3x70
3x95
3x120
3x150
3x185
3x240
3x300
3x400
4x1.5
4x2.5
4x4
4x6
4x10
4x16
4x25
4x35
4x50
4x70
4x95
4x120
4x150
4x185
4x240
4x300
4x400
5x1.5
5x2.5
5x4
5x6
5x10
5x16
5x25
5x35
5x50
5x70
5x95
5x120
5x150
5x185
5x240
5x300
5x400
CU/PVC/PVC/AWA/PVC
Single core PVC Insulated cables with copper conductor and aluminium wires armour
Standard: IEC 60502.1
Rated voltage: 0.6/1(1.2)kV
Test voltage: 3.5kV/5mins
Max. Short-circuit temperature: 160℃ (CSA≤300mm2), 140℃ (CSA>300mm2)
Operating conductor temperature: 70℃
Min. temperature for laying and manipulation with cables: -5℃
Temperature range for operating: from -35 to +70℃
Colour of insulation: White
Colour of sheath: Black
Min. bending radius: 15 OD
Packing: Cable Drum
Optional
The cable design based on AS/NZS, SANS, NBR, ICEA, BS, EN, AEIC etc. is also available. Flame retardant, Fire resistant, Low smoke & Low halogen, Cold resistant, UV resistant, Oil resistant, Anti-rodent, Anti-termite, water proof is also available.
Application
For fixed installation, indoors and outdoors, in the ground and in concrete with higher risk of mechanical damage. The cables are resistant to UV radiation and to flame propagation according to IEC 60332.
No. Cores &Cross section area
Approx. diameter of conductor
Product Parameter
Max. AC resistance
of conductor
at 90ºC
Max. diameter of cable
Approx. mass of cable
Max. DC resistance of conductor
at 20ºC
Fault current carrying of
conductor (1s)
Max. allowable pulling force of conductor
mm mm kNΩ/km
1.53
1.98
2.49
3.06
4.05
5.1
6.0
7.0
8.1
9.8
11.4
12.9
14.4
16.0
18.4
20.6
23.4
26.2
29.8
13.4
13.8
14.7
15.3
16.3
17.3
18.6
20.5
22.0
23.7
26.4
27.9
29.8
31.9
34.9
38.5
42.4
45.9
51.1
162
181
218
249
311
390
508
664
822
1058
1406
1676
2001
2411
3050
3809
4766
5926
7545
12.1
7.41
4.61
3.08
1.83
1.15
0.727
0.524
0.387
0.268
0.193
0.153
0.124
0.0991
0.0754
0.0601
0.0470
0.0366
0.0283
14.5
8.87
5.52
3.69
2.19
1.38
0.870
0.627
0.463
0.321
0.232
0.184
0.150
0.120
0.0923
0.0746
0.0596
0.0481
0.0393
0.19
0.31
0.48
0.71
1.17
1.78
2.78
3.90
5.57
7.79
10.58
13.36
16.70
20.60
26.72
33.40
39.47
49.34
62.17
0.37
0.41
0.47
0.51
0.59
0.67
0.74
1.29
1.44
1.63
2.35
2.59
2.90
3.14
3.53
4.90
5.51
6.13
8.42
kg/km Ω/km kA
1x1.5
1x2.5
1x4
1x6
1x10
1x16
1x25
1x35
1x50
1x70
1x95
1x120
1x150
1x185
1x240
1x300
1x400
1x500
1x630
Copper conductor
PVC insulation
PVC inner sheath
Hard-drawn aluminium wires
Binder tape
PVC outer sheath
2221 Low Voltage Power CableLow Voltage Power Cable
CU/PVC/PVC/SWA/PVC
Multi core PVC Insulated cables with copper conductor and steel wires armour
Standard: IEC 60502.1
Rated voltage: 0.6/1(1.2)kV
Test voltage: 3.5kV/5mins
Max. Short-circuit temperature: 160℃ (CSA≤300mm2), 140℃ (CSA>300mm2)
Operating conductor temperature: 70℃
Min. temperature for laying and manipulation with cables: -5℃
Temperature range for operating: from -35 to +70℃
Colour of insulation: Table 1
Colour of sheath: Black
Min. bending radius: 120D
Packing: Cable Drum
Optional
The cable design based on AS/NZS, SANS, NBR, ICEA, BS, EN, AEIC etc. is also available. Flame retardant, Fire resistant, Low smoke & Low halogen, Cold resistant, UV resistant, Oil resistant, Anti-rodent, Anti-termite, water proof is also available.
Application
For fixed installation, indoors and outdoors, in the ground and in concrete with higher risk of mechanical damage. The cables are resistant to UV radiation and to flame propagation according to IEC 60332.
No. Cores &Cross section area
Approx. diameter of conductor
Product Parameter
Max. AC resistance
of conductor
at 90ºC
Max. diameter of cable
Approx. mass of cable
Max. DC resistance of conductor
at 20ºC
Fault current carrying of
conductor (1s)
Max. allowable pulling force of conductor
mm mm kNΩ/km
1.53
1.98
2.49
3.06
4.05
5.1
6.0
7.0
8.1
9.8
11.4
12.9
14.4
16.0
18.4
20.6
23.4
1.53
1.98
17.1
18.0
19.8
21.8
23.8
25.9
29.2
31.2
34.4
38.9
43.6
47.0
52.4
57.3
63.5
69.8
77.0
17.6
18.6
361
410
511
709
873
1082
1520
1816
2255
3084
3928
4605
5832
7012
8633
10423
12694
399
459
12.1
7.41
4.61
3.08
1.83
1.15
0.727
0.524
0.387
0.268
0.193
0.153
0.124
0.0991
0.0754
0.0601
0.0470
12.1
7.41
14.5
8.87
5.52
3.69
2.19
1.38
0.870
0.627
0.464
0.322
0.232
0.185
0.150
0.121
0.0937
0.0762
0.0616
14.5
8.87
0.19
0.31
0.48
0.71
1.17
1.78
2.78
3.90
5.57
7.79
10.58
13.36
16.70
20.60
26.72
33.40
39.47
0.19
0.31
1.74
1.90
2.27
3.87
4.38
5.03
7.39
8.23
9.50
13.52
15.50
16.82
23.19
26.29
29.38
32.99
36.59
1.85
2.01
kg/km Ω/km kA
2x1.5
2x2.5
2x4
2x6
2x10
2x16
2x25
2x35
2x50
2x70
2x95
2x120
2x150
2x185
2x240
2x300
2x400
3x1.5
3x2.5
No. Cores &Cross section area
Approx. diameter of conductor
Product Parameter
Max. AC resistance
of conductor
at 90ºC
Max. diameter of cable
Approx. mass of cable
Max. DC resistance of conductor
at 20ºC
Fault current carrying of
conductor (1s)
Max. allowable pulling force of conductor
mm mm kNΩ/km
2.49
3.06
4.05
5.1
6.0
7.0
8.1
9.8
11.4
12.9
14.4
16.0
18.4
20.6
23.4
1.53
1.98
2.49
3.06
4.05
5.1
6.0
7.0
8.1
9.8
11.4
12.9
14.4
16.0
18.4
20.6
23.4
1.53
1.98
2.49
3.06
4.05
5.1
6.0
7.0
8.1
9.8
11.4
12.9
14.4
16.0
18.4
20.6
23.4
21.4
22.7
24.8
27.8
30.6
32.8
36.3
41.5
46.3
49.9
56.0
60.9
68.1
74.3
83.6
18.5
19.5
22.6
24.0
26.4
29.7
32.9
35.5
40.7
45.2
51.7
56.2
61.3
67.2
74.8
81.8
92.4
19.4
21.5
24.0
25.5
28.9
31.7
35.4
39.2
44.1
49.2
56.8
61.3
67.5
73.5
83.4
91.7
101.5
698
811
1028
1426
1848
2243
2811
3901
4978
5914
7524
8986
11305
13641
17620
449
525
801
936
1210
1681
2225
2726
3734
4806
6587
7892
9381
11327
14199
17173
22271
501
706
908
1066
1532
1960
2620
3474
4445
5737
7926
9447
11342
13680
18063
21938
27041
4.61
3.08
1.83
1.15
0.727
0.524
0.387
0.268
0.193
0.153
0.124
0.0991
0.0754
0.0601
0.0470
12.1
7.41
4.61
3.08
1.83
1.15
0.727
0.524
0.387
0.268
0.193
0.153
0.124
0.0991
0.0754
0.0601
0.0470
12.1
7.41
4.61
3.08
1.83
1.15
0.727
0.524
0.387
0.268
0.193
0.153
0.124
0.0991
0.0754
0.0601
0.0470
5.52
3.69
2.19
1.38
0.870
0.627
0.464
0.322
0.232
0.185
0.150
0.121
0.0937
0.0762
0.0616
14.5
8.87
5.52
3.69
2.19
1.38
0.870
0.627
0.464
0.322
0.232
0.185
0.150
0.121
0.0937
0.0762
0.0616
14.5
8.87
5.52
3.69
2.19
1.38
0.870
0.627
0.464
0.322
0.232
0.185
0.150
0.121
0.0937
0.0762
0.0616
0.48
0.71
1.17
1.78
2.78
3.90
5.57
7.79
10.58
13.36
16.70
20.60
26.72
33.40
39.47
0.19
0.31
0.48
0.71
1.17
1.78
2.78
3.90
5.57
7.79
10.58
13.36
16.70
20.60
26.72
33.40
39.47
0.19
0.31
0.48
0.71
1.17
1.78
2.78
3.90
5.57
7.79
10.58
13.36
16.70
20.60
26.72
33.40
39.47
3.74
4.12
4.77
6.97
8.02
8.87
10.13
14.51
16.49
18.14
25.26
27.83
31.96
35.56
49.91
2.01
2.22
4.12
4.51
5.28
7.60
8.87
9.71
14.18
16.16
23.19
25.77
28.35
31.44
35.56
39.17
55.64
2.16
3.74
4.51
4.90
7.39
8.44
9.71
13.52
15.83
17.81
25.77
28.35
31.44
35.05
49.91
55.64
62.19
kg/km Ω/km kA
3x4
3x6
3x10
3x16
3x25
3x35
3x50
3x70
3x95
3x120
3x150
3x185
3x240
3x300
3x400
4x1.5
4x2.5
4x4
4x6
4x10
4x16
4x25
4x35
4x50
4x70
4x95
4x120
4x150
4x185
4x240
4x300
4x400
5x1.5
5x2.5
5x4
5x6
5x10
5x16
5x25
5x35
5x50
5x70
5x95
5x120
5x150
5x185
5x240
5x300
5x400
Copper conductor
PVC insulation
Filler
Binder tape
PVC inner sheath
Galvanized steel wires
Binder tape
PVC outer sheath
2423 Low Voltage Power CableLow Voltage Power Cable
AL/PVC/PVC
Single core PVC insulated cables with aluminium conductor
Standard: IEC 60502.1
Rated voltage: 0.6/1(1.2)kV
Test voltage: 3.5kV/5mins
Max. Short-circuit temperature: 160℃ (CSA≤300mm2), 140℃ (CSA>300mm2)
Operating conductor temperature: 70℃
Min. temperature for laying and manipulation with cables: -5℃
Temperature range for operating: from -35 to +70℃
Colour of insulation: White
Colour of sheath: Black
Min. bending radius: 20 OD
Packing: Cable Drum
Optional
The cable design based on AS/NZS, SANS, NBR, ICEA, BS, EN, AEIC etc. is also available. Flame retardant, Fire resistant, Low smoke & Low halogen, Cold resistant, UV resistant, Oil resistant, Anti-rodent, Anti-termite, water proof is also available.
Application
For fixed installation, indoors and outdoors, in the ground and in concrete. The cables are resistant to UV radiation and to flame propagation according to IEC 60332.
No. Cores &Cross section area
Approx. diameter of conductor
Product Parameter
Max. AC resistance
of conductor
at 90ºC
Max. diameter of cable
Approx. mass of cable
Max. DC resistance of conductor
at 20ºC
Fault current carrying of
conductor (1s)
Max. allowable pulling force of conductor
mm mm kNΩ/km kg/km Ω/km kA
Aluminium conductor
PVC insulation
PVC sheath
3.99
5.07
6.0
7.0
8.1
9.8
11.4
12.9
14.4
16.0
18.4
20.6
23.4
26.2
29.8
11.0
12.1
13.4
14.4
15.9
17.7
19.9
21.5
23.5
25.6
28.6
31.4
34.8
38.2
42.1
1x10
1x16
1x25
1x35
1x50
1x70
1x95
1x120
1x150
1x185
1x240
1x300
1x400
1x500
1x630
100
128
174
211
271
353
465
558
678
831
1060
1298
1630
2034
2518
3.08
1.91
1.20
0.868
0.641
0.443
0.320
0.253
0.206
0.164
0.125
0.100
0.0778
0.0605
0.0469
3.70
2.29
1.44
1.04
0.77
0.533
0.385
0.305
0.249
0.198
0.152
0.122
0.0963
0.0763
0.0611
1.06
1.60
2.50
3.50
5.00
6.99
9.49
11.99
14.99
18.49
23.98
29.98
39.97
49.96
62.95
0.39
0.62
0.98
1.37
1.95
2.73
3.71
4.68
5.85
7.22
9.36
11.70
15.60
19.50
24.57
AL/PVC/PVC
Multi core PVC insulated cables with aluminium conductor
Standard: IEC 60502.1
Rated voltage: 0.6/1(1.2)kV
Test voltage: 3.5kV/5mins
Max. Short-circuit temperature: 160℃ (CSA≤300mm2), 140℃ (CSA>300mm2)
Operating conductor temperature: 70℃
Min. temperature for laying and manipulation with cables: -5℃
Temperature range for operating: from -35 to +70℃
Colour of insulation: Table 1
Colour of sheath: Black
Min. bending radius: 15 OD
Packing: Cable Drum
Optional
The cable design based on AS/NZS, SANS, NBR, ICEA, BS, EN, AEIC etc. is also available. Flame retardant, Fire resistant, Low smoke & Low halogen, Cold resistant, UV resistant, Oil resistant, Anti-rodent, Anti-termite, water proof is also available.
Application
For fixed installation, indoors and outdoors, in the ground and in concrete. The cables are resistant to UV radiation and to flame propagation according to IEC 60332.
No. Cores &Cross section area
Approx. diameter of conductor
Product Parameter
Max. AC resistance
of conductor
at 90ºC
Max. diameter of cable
Approx. mass of cable
Max. DC resistance of conductor
at 20ºC
Fault current carrying of
conductor (1s)
Max. allowable pulling force of conductor
mm mm kNΩ/km
3.99
5.07
6.0
7.0
8.1
9.8
11.4
12.9
14.4
16.0
18.4
20.6
23.4
3.99
5.07
6.0
7.0
8.1
9.8
18.3
20.5
23.2
25.2
28.2
31.8
36.0
39.2
43.3
47.8
54.1
59.9
67.1
19.3
21.7
24.5
26.7
30.1
33.9
2x10
2x16
2x25
2x35
2x50
2x70
2x95
2x120
2x150
2x185
2x240
2x300
2x400
3x10
3x16
3x25
3x35
3x50
3x70
258
331
445
540
689
898
1187
1426
1741
2135
2729
3349
4214
313
407
558
683
886
1164
3.08
1.91
1.20
0.868
0.641
0.443
0.320
0.253
0.206
0.164
0.125
0.100
0.0778
3.08
1.91
1.20
0.868
0.641
0.443
3.70
2.29
1.44
1.04
0.771
0.533
0.385
0.305
0.249
0.199
0.152
0.123
0.0969
3.70
2.29
1.44
1.04
0.771
0.533
1.06
1.60
2.50
3.50
5.00
6.99
9.49
11.99
14.99
18.49
23.98
29.98
39.97
1.06
1.60
2.50
3.50
5.00
6.99
0.78
1.25
1.95
2.73
3.90
5.46
7.41
9.36
11.70
14.43
18.72
23.40
31.20
1.17
1.87
2.93
4.10
5.85
8.19
kg/km Ω/km kA
Aluminium conductor
PVC insulation
Filler
Binder tape
PVC sheath
2625 Low Voltage Power CableLow Voltage Power Cable
No. Cores &Cross section area
Approx. diameter of conductor
Max. AC resistance
of conductor
at 90ºC
Max. diameter of cable
Approx. mass of cable
Max. DC resistance of conductor
at 20ºC
Fault current carrying of
conductor (1s)
Max. allowable pulling force of conductor
mm mm kNΩ/km kg/km Ω/km kA
Product Parameter
38.6
42.0
46.6
51.4
58.2
64.5
72.3
20.9
23.6
26.8
29.2
33.1
37.5
42.7
46.8
51.9
57.3
64.9
71.9
80.7
22.7
25.6
29.2
32.1
36.5
41.3
47.3
51.9
57.6
63.7
72.1
80.0
89.7
1548
1864
2279
2805
3595
4420
5571
382
501
693
855
1126
1484
1979
2388
2923
3604
4626
5695
7187
455
600
836
1048
1384
1827
2441
2949
3614
4460
5730
7059
8916
11.12
14.04
17.55
21.65
28.08
35.10
46.80
1.56
2.50
3.90
5.46
7.80
10.92
14.82
18.72
23.40
28.86
37.44
46.80
62.40
1.95
3.12
4.88
6.83
9.75
13.65
18.53
23.40
29.25
36.08
46.80
58.50
78.00
9.49
11.99
14.99
18.49
23.98
29.98
39.97
1.06
1.60
2.50
3.50
5.00
6.99
9.49
11.99
14.99
18.49
23.98
29.98
39.97
1.06
1.60
2.50
3.50
5.00
6.99
9.49
11.99
14.99
18.49
23.98
29.98
39.97
0.385
0.305
0.249
0.199
0.152
0.123
0.0969
3.70
2.29
1.44
1.04
0.771
0.533
0.385
0.305
0.249
0.199
0.152
0.123
0.0969
3.70
2.29
1.44
1.04
0.771
0.533
0.385
0.305
0.249
0.199
0.152
0.123
0.0969
0.320
0.253
0.206
0.164
0.125
0.100
0.0778
3.08
1.91
1.20
0.868
0.641
0.443
0.320
0.253
0.206
0.164
0.125
0.100
0.0778
3.08
1.91
1.20
0.868
0.641
0.443
0.320
0.253
0.206
0.164
0.125
0.100
0.0778
11.4
12.9
14.4
16.0
18.4
20.6
23.4
3.99
5.07
6.0
7.0
8.1
9.8
11.4
12.9
14.4
16.0
18.4
20.6
23.4
3.99
5.07
6.0
7.0
8.1
9.8
11.4
12.9
14.4
16.0
18.4
20.6
23.4
3x95
3x120
3x150
3x185
3x240
3x300
3x400
4x10
4x16
4x25
4x35
4x50
4x70
4x95
4x120
4x150
4x185
4x240
4x300
4x400
5x10
5x16
5x25
5x35
5x50
5x70
5x95
5x120
5x150
5x185
5x240
5x300
5x400
AL/PVC/PVC/AWA/PVC
Single core PVC Insulated cables with aluminium conductor and aluminium wires armour
Standard: IEC 60502.1
Rated voltage: 0.6/1(1.2)kV
Test voltage: 3.5kV/5mins
Max. Short-circuit temperature: 160℃ (CSA≤300mm2), 140℃ (CSA>300mm2)
Operating conductor temperature: 70℃
Min. temperature for laying and manipulation with cables: -5℃
Temperature range for operating: from -35 to +70℃
Colour of insulation: White
Colour of sheath: Black
Min. bending radius: 15 OD
Packing: Cable Drum
Optional
The cable design based on AS/NZS, SANS, NBR, ICEA, BS, EN, AEIC etc. is also available. Flame retardant, Fire resistant, Low smoke & Low halogen, Cold resistant, UV resistant, Oil resistant, Anti-rodent, Anti-termite, water proof is also available.
Application
For fixed installation, indoors and outdoors, in the ground and in concrete with higher risk of mechanical damage. The cables are resistant to UV radiation and to flame propagation according to IEC 60332.
No. Cores &Cross section area
Approx. diameter of conductor
Product Parameter
Max. AC resistance
of conductor
at 90ºC
Max. diameter of cable
Approx. mass of cable
Max. DC resistance of conductor
at 20ºC
Fault current carrying of
conductor (1s)
Max. allowable pulling force of conductor
mm mm kNΩ/km
3.99
5.07
6.0
7.0
8.1
9.8
11.4
12.9
14.4
16.0
18.4
20.6
23.4
26.2
29.8
16.2
17.3
18.6
20.5
22.0
23.7
26.4
27.9
29.8
31.9
34.9
38.5
42.4
45.9
51.1
1x10
1x16
1x25
1x35
1x50
1x70
1x95
1x120
1x150
1x185
1x240
1x300
1x400
1x500
1x630
248
291
353
448
530
636
819
936
1087
1269
1549
1923
2359
2837
3544
3.08
1.91
1.20
0.868
0.641
0.443
0.320
0.253
0.206
0.164
0.125
0.100
0.0778
0.0605
0.0469
3.70
2.29
1.44
1.04
0.770
0.533
0.385
0.305
0.248
0.198
0.151
0.122
0.0956
0.0755
0.0600
0.78
1.18
1.84
2.58
3.68
5.15
6.99
8.83
11.04
13.62
17.66
22.08
26.10
32.62
41.11
0.59
0.67
0.74
1.29
1.44
1.63
2.35
2.59
2.90
3.14
3.53
4.90
5.51
6.13
8.42
kg/km Ω/km kA
Aluminium conductor
PVC inner sheath
PVC inner sheath
Hard-drawn aluminium wires
Binder tape
PVC outer sheath
2827 Low Voltage Power CableLow Voltage Power Cable
AL/PVC/PVC/SWA/PVC
Multi core PVC Insulated cables with aluminium conductor and steel wires armour
Standard: IEC 60502.1
Rated voltage: 0.6/1(1.2)kV
Test voltage: 3.5kV/5mins
Max. Short-circuit temperature: 160℃ (CSA≤300mm2), 140℃ (CSA>300mm2)
Operating conductor temperature: 70℃
Min. temperature for laying and manipulation with cables: -5℃
Temperature range for operating: from -35 to +70℃
Colour of insulation: Table 1
Colour of sheath: Black
Min. bending radius: 120D
Packing: Cable Drum
Optional
The cable design based on AS/NZS, SANS, NBR, ICEA, BS, EN, AEIC etc. is also available. Flame retardant, Fire resistant, Low smoke & Low halogen, Cold resistant, UV resistant, Oil resistant, Anti-rodent, Anti-termite, water proof is also available.
Application
For fixed installation, indoors and outdoors, in the ground and in concrete with higher risk of mechanical damage. The cables are resistant to UV radiation and to flame propagation according to IEC 60332.
No. Cores &Cross section area
Approx. diameter of conductor
Product Parameter
Max. AC resistance
of conductor
at 90ºC
Max. diameter of cable
Approx. mass of cable
Max. DC resistance of conductor
at 20ºC
Fault current carrying of
conductor (1s)
Max. allowable pulling force of conductor
mm mm kNΩ/km
3.99
5.07
6.0
7.0
8.1
9.8
11.4
12.9
14.4
16.0
18.4
20.6
23.4
3.99
5.07
6.0
7.0
8.1
9.8
23.7
25.8
29.2
31.2
34.4
38.9
43.6
47.0
52.4
57.3
63.5
69.8
77.0
24.7
27.7
30.6
32.8
36.3
41.5
2x10
2x16
2x25
2x35
2x50
2x70
2x95
2x120
2x150
2x185
2x240
2x300
2x400
3x10
3x16
3x25
3x35
3x50
3x70
744
882
1208
1383
1667
2236
2749
3120
3996
4719
5616
6632
7858
826
1127
1379
1592
1929
2630
3.08
1.91
1.20
0.868
0.641
0.443
0.320
0.253
0.206
0.164
0.125
0.100
0.0778
3.08
1.91
1.20
0.868
0.641
0.443
3.70
2.29
1.44
1.04
0.771
0.533
0.385
0.305
0.249
0.199
0.152
0.123
0.0969
3.70
2.29
1.44
1.04
0.771
0.533
0.78
1.18
1.84
2.58
3.68
5.15
6.99
8.83
11.04
13.62
17.66
22.08
26.10
0.78
1.18
1.84
2.58
3.68
5.15
4.38
5.03
7.39
8.23
9.50
13.52
15.50
16.82
23.19
26.29
29.38
32.99
36.59
4.64
6.97
8.02
8.87
10.13
14.51
kg/km Ω/km kA
No. Cores &Cross section area
Approx. diameter of conductor
Max. AC resistance
of conductor
at 90ºC
Max. diameter of cable
Approx. mass of cable
Max. DC resistance of conductor
at 20ºC
Fault current carrying of
conductor (1s)
Max. allowable pulling force of conductor
mm mm kNΩ/km kg/km Ω/km kA
Product Parameter
46.3
49.9
56.0
60.9
68.1
74.3
83.6
26.3
29.6
32.9
35.5
40.7
45.2
51.7
56.2
61.3
67.2
74.8
81.8
92.4
28.7
31.6
35.4
39.2
44.1
49.2
56.8
61.3
67.5
73.5
83.4
91.7
101.5
3210
3687
4770
5545
6779
7955
10364
946
1283
1601
1858
2559
3110
4229
4921
5709
6739
8165
9591
12597
1198
1463
1839
2389
2977
3617
4980
5734
6752
7946
10521
12461
14949
16.49
18.14
25.26
27.83
31.96
35.56
49.91
5.15
7.60
8.87
9.71
14.18
16.16
23.19
25.77
28.35
31.44
35.56
39.17
55.64
7.18
8.44
9.71
13.52
15.83
17.81
25.77
28.35
31.44
35.05
49.91
55.64
62.19
6.99
8.83
11.04
13.62
17.66
22.08
26.10
0.78
1.18
1.84
2.58
3.68
5.15
6.99
8.83
11.04
13.62
17.66
22.08
26.10
0.78
1.18
1.84
2.58
3.68
5.15
6.99
8.83
11.04
13.62
17.66
22.08
26.10
0.385
0.305
0.249
0.199
0.152
0.123
0.0969
3.70
2.29
1.44
1.04
0.771
0.533
0.385
0.305
0.249
0.199
0.152
0.123
0.0969
3.70
2.29
1.44
1.04
0.771
0.533
0.385
0.305
0.249
0.199
0.152
0.123
0.0969
0.320
0.253
0.206
0.164
0.125
0.100
0.0778
3.08
1.91
1.20
0.868
0.641
0.443
0.320
0.253
0.206
0.164
0.125
0.100
0.0778
3.08
1.91
1.20
0.868
0.641
0.443
0.320
0.253
0.206
0.164
0.125
0.100
0.0778
11.4
12.9
14.4
16.0
18.4
20.6
23.4
3.99
5.07
6.0
7.0
8.1
9.8
11.4
12.9
14.4
16.0
18.4
20.6
23.4
3.99
5.07
6.0
7.0
8.1
9.8
11.4
12.9
14.4
16.0
18.4
20.6
23.4
3x95
3x120
3x150
3x185
3x240
3x300
3x400
4x10
4x16
4x25
4x35
4x50
4x70
4x95
4x120
4x150
4x185
4x240
4x300
4x400
5x10
5x16
5x25
5x35
5x50
5x70
5x95
5x120
5x150
5x185
5x240
5x300
5x400
Aluminium conductor
PVC insulation
Filler
Binder tape
PVC inner sheath
Galvanized steel wires
Binder tape
PVC outer sheath
3029 Low Voltage Power CableLow Voltage Power Cable
Recommended Multi Core Identification
Recommended Multi Core Identification
Phase A
Phase B
Phase C
Natural core
Earth core
Brown
Black
Grey
Blue
Yellow/Green
Red
Yellow
Blue
Black
Yellow/Green
Red
Yellow
Green
Blue
Black
Red
White (or neutral)
Blue
Black
Yellow/Green
White for single PVC insulation core, Neutral for single XLPE insulation core.
Maximum D.C. resistances of conductor at 20℃
Nominal cross-sectional area
Category
2mm
1.5
2.5
4
6
10
16
25
35
50
70
95
120
150
185
240
300
400
500
630
800
12.1
7.41
4.61
3.08
--
--
--
--
--
--
--
--
--
--
--
--
--
--
--
--
Plain
Ω/kM
Tinned
Ω/kM
Plain
Ω/kM
Tinned
Ω/kM Ω/kM
Plain
Ω/kM
Tinned
Ω/kM
Plain
Ω/kM
Tinned
Ω/kM
Copper Aluminium
Class 1 Class 2 Class 5 Class 6
Copper Copper Copper Copper
12.2
7.56
4.70
3.11
--
--
--
--
--
--
--
--
--
--
--
--
--
--
--
--
12.1
7.41
4.61
3.08
1.83
1.15
0.727
0.524
0.387
0.268
0.193
0.153
0.124
0.0991
0.0754
0.0601
0.0470
0.0366
0.0283
0.0221
12.2
7.56
4.70
3.11
1.84
1.16
0.734
0.529
0.391
0.270
0.195
0.154
0.126
0.100
0.0762
0.0607
0.0475
0.0369
0.0286
0.0224
--
--
--
--
3.08
1.91
1.20
0.868
0.641
0.443
0.320
0.253
0.206
0.164
0.125
0.100
0.0778
0.0605
0.0469
0.367
13.3
7.98
4.95
3.30
1.91
1.21
0.780
0.554
0.386
0.272
0.206
0.161
0.129
0.106
0.0801
0.0641
0.0486
0.0384
0.0287
--
13.7
8.21
5.09
3.39
1.95
1.24
0.795
0.565
0.393
0.277
0.210
0.164
0.132
0.108
0.0817
0.0654
0.0495
0.0391
0.0292
--
13.3
7.98
4.95
3.30
1.91
1.21
0.780
0.554
0.386
0.272
0.206
0.161
0.129
0.106
0.0801
0.0641
--
--
--
--
13.7
8.21
5.09
3.39
1.95
1.24
0.795
0.565
0.393
0.277
0.210
0.164
0.132
0.108
0.0817
0.0654
--
--
--
--
3231 Low Voltage Power CableLow Voltage Power Cable
Rating Factors
Conductor temperature ℃
150
110
90
80
70
Rating factor
Air and concrete slab ambient temperature, ℃
VARIANCE:
INSTALLATION CONDITIONS:
AIR AND CONCRETE SLAB AMBIENT TEMPERATURES
CABLES IN AIR OR HEATED CONCRETE SLABS
15
1.11
1.16
1.26
1.31
1.35
20
1.09
1.13
1.2
1.25
1.28
25
1.07
1.1
1.15
1.19
1.21
35
1.02
1.04
1.05
1.06
1.07
40
1
1
1
1
1
45
0.98
0.96
0.94
0.92
0.91
50
0.95
0.93
0.88
0.84
0.82
55
0.93
0.89
0.81
0.76
0.72
60
0.9
0.85
0.73
0.66
0.6
65
0.88
0.8
0.65
0.56
0.49
70
0.85
0.76
0.57
0.45
0.37
75
0.83
0.71
0.47
0.27
—
80
0.8
0.65
0.34
—
—
85
0.77
0.6
0.19
—
—
90
0.74
0.53
—
—
—
100
0.69
0.38
—
—
—
110
0.6
—
—
—
—
120
0.52
—
—
—
—
130
0.43
—
—
—
—
140
0.3
—
—
—
—
Conductor temperature ℃
90
80
70
Rating factor
Soil ambient temperature, ℃
VARIANCE:
INSTALLATION CONDITIONS:
SOIL AMBIENT TEMPERATURE
CABLE BURIED DIRECT IN GROUND OR IN UNDERGROUND WIRING ENCLOSURES
10
1.11
1.13
1.14
15
1.07
1.09
1.1
20
1.03
1.04
1.05
25
1.0
1.0
1.0
30
0.97
0.96
0.95
35
0.93
0.91
0.89
40
0.89
0.85
0.83
Depth of laying m
0.5
0.6
0.8
1
1.25
1.5
1.75
2
2.5
3.0 or more
Rating factor
2 Conductor size, mm
CABLE TYPES:
VARIANCE:
INSTALLATION CONDITIONS:
Up to 50
1.00
0.99
0.97
0.95
0.94
0.93
0.92
0.91
0.90
0.89
Above 50 to 300
1.00
0.98
0.96
0.94
0.92
0.91
0.89
0.88
0.87
0.86
Above 300
1.00
0.97
0.94
0.92
0.90
0.89
0.87
0.86
0.85
0.83
SINGLE-CORE OR MULTICORE
DEPTH OF LAYING
BURIED DIRECT IN GROUND
Depth of laying m
0.5
0.6
0.8
1
1.25
1.5
1.75
2
2.5
3.0 or more
Rating factor
CABLE TYPES:
VARIANCE:
INSTALLATION CONDITIONS:
Single-core
1.00
0.98
0.95
0.93
0.90
0.89
0.88
0.87
0.86
0.85
Multicore
1.00
0.99
0.97
0.96
0.95
0.94
0.94
0.93
0.93
0.92
SINGLE-CORE OR MULTICORE
DEPTH OF LAYING
IN UNDERGROUND WIRING ENCLOSURES
Thermal resistivity of soil °C.m/W
0.8
0.9
1.0
1.2
1.5
2.0
2.5
3.0
Rating factor
VARIANCE:
INSTALLATION CONDITIONS:
THERMAL RESISTIVITY OF THE SOIL (FROM 1.2°C.m/W)
BURIED DIRECT IN GROUND AND IN UNDERGROUND WIRING ENCLOSURES
Multicore cable buried direct
Two or three single-core cables buried direct
Multicore cable in a wiring enclosure
Three single-core cables in a wiring enclosure*
Two single-core cables in a wiring enclosure*
1.09
1.07
1.04
1.00
0.92
0.81
0.74
0.69
1.16
1.11
1.07
1.00
0.9
0.8
0.72
0.66
1.03
1.02
1.02
1.00
0.95
0.88
0.83
0.78
1.08
1.06
1.04
1.00
0.92
0.83
0.77
0.71
1.06
1.04
1.03
1.00
0.94
0.86
0.8
0.75
* These rating factors apply to single-core cables enclosed separately, or grouped in a single wiring enclosure.
3433 Low Voltage Power CableLow Voltage Power Cable
Current-carrying Capacities
Conductor size 2mm
Current-carrying capacity, A
Unenclosed
CABLE TYPE:
INSULATION TYPE:
MAXIMUM CONDUCTOR TEMPERATURE:
REFERENCE AMBIENT TEMPERATURE:
SINGLE-CORE
PVC
70°C
40°C IN AIR, 25°C IN GROUND
Stranded/Solid
Space Space from surface Touching Exposed to sun
CU CU CU CU
Flexible AL Stranded/Solid Flexible AL Stranded/Solid Flexible AL Stranded/Solid Flexible AL
1.5
2.5
4
6
10
16
25
35
50
70
95
120
150
185
240
300
400
500
630
20
29
38
49
67
89
120
148
181
230
287
335
385
447
535
620
726
846
990
21
27
37
47
66
88
117
145
183
231
279
331
383
438
528
609
734
855
1011
—
—
—
—
—
69
93
115
141
179
222
260
298
347
417
483
570
669
789
17
25
33
42
58
77
103
127
156
197
246
287
330
383
457
529
615
710
817
18
24
32
41
57
75
100
125
157
198
239
284
328
376
451
519
621
717
833
—
—
—
—
—
59
80
98
121
153
191
223
256
299
358
415
488
571
668
16
23
31
40
54
72
97
119
146
184
230
267
308
357
426
492
573
661
760
17
22
30
38
54
71
94
117
147
185
223
264
305
350
420
484
578
668
775
—
—
—
—
—
56
75
92
113
143
178
208
239
278
334
387
455
532
622
10
13
18
22
30
39
50
61
72
89
107
122
137
154
176
197
219
242
265
10
13
17
21
29
38
49
59
73
89
104
120
135
149
172
191
216
237
262
—
—
—
—
—
30
39
47
56
69
83
95
106
120
138
155
175
196
219
Conductor size 2mm
Current-carrying capacity, A
CABLE TYPE:
INSULATION TYPE:
MAXIMUM CONDUCTOR TEMPERATURE:
REFERENCE AMBIENT TEMPERATURE:
SINGLE-CORE
PVC
70°C
40°C IN AIR, 25°C IN GROUND
Stranded/Solid
Enclosed Thermal insulation Buried direct Underground wiring enclosure
CU CU
Flexible AL AL Stranded/Solid Flexible AL
1.5
2.5
4
6
10
16
25
35
50
70
95
120
150
185
240
300
400
500
630
15
21
28
35
47
62
81
100
119
152
183
217
244
284
331
388
442
523
588
15
20
27
34
46
61
78
98
120
152
178
213
241
277
336
379
461
520
592
—
—
—
—
—
48
63
78
92
118
142
169
190
222
269
305
351
421
481
12
17
23
28
37
50
64
80
95
122
147
173
195
227
265
311
353
418
471
—
—
—
—
—
39
50
62
74
94
114
135
152
177
207
244
281
337
385
—
—
—
—
—
28
38
46
—
—
—
—
—
—
—
—
—
—
—
20
27
36
45
59
104
134
160
190
233
279
317
356
402
465
524
593
668
748
20
27
36
45
59
78
100
122
144
180
217
252
283
325
377
434
492
571
639
20
26
35
43
58
76
97
119
145
180
210
247
279
316
376
423
504
566
641
—
—
—
—
—
60
78
94
112
140
168
196
220
253
295
341
391
459
523
CU AL AL AL CU CU CU
8
12
16
20
27
36
48
59
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
81
104
124
147
181
216
247
276
313
364
412
471
537
612
24
33
43
53
70
90
117
140
168
205
250
283
317
365
422
488
553
641
723
—
—
—
—
—
70
91
108
131
159
194
220
246
284
329
380
434
507
578
1. Applies to non-armoured, sheathed or unsheathed cables.
2. Air and concrete slab ambient temperature: 40
3. Soil ambient temperature: 25
4. Depth of laying: 0.5m
5. Thermal resistivity of the soil: 1.2℃.m/W
Notes: 1. Applies to non-armoured, sheathed or unsheathed cables.
2. Air and concrete slab ambient temperature: 40
3. Soil ambient temperature: 25
4. Depth of laying: 0.5m
5. Thermal resistivity of the soil: 1.2℃.m/W
Notes:
Wiring enclosure in air Partially surroundedby thermal insulation
Completely surrounded by thermal insulation
3635 Low Voltage Power CableLow Voltage Power Cable
Current-carrying Capacities
Conductor size 2mm
Current-carrying capacity, A
Unenclosed
CABLE TYPE:
INSULATION TYPE:
MAXIMUM CONDUCTOR TEMPERATURE:
REFERENCE AMBIENT TEMPERATURE:
SINGLE-CORE
XLPE
90°C
40°C IN AIR, 25°C IN GROUND
Stranded/Solid
Space Space from surface Touching Exposed to sun
CU CU CU CU
Flexible AL Stranded/Solid Flexible AL Stranded/Solid Flexible AL Stranded/Solid Flexible AL
1.5
2.5
4
6
10
16
25
35
50
70
95
120
150
185
240
300
400
500
630
25
35
46
59
81
108
146
180
221
282
350
410
472
560
660
766
899
1051
1230
25
33
45
57
80
106
142
177
223
283
341
406
470
540
651
752
909
1062
1256
—
—
—
—
—
84
113
140
171
219
271
318
366
427
513
596
705
829
978
21
30
40
50
69
92
125
154
188
240
298
349
403
468
560
648
756
874
1010
22
29
38
49
69
91
121
151
191
241
290
346
400
459
553
637
764
884
1030
—
—
—
—
—
71
97
119
146
186
232
271
313
365
438
508
599
703
824
120
28
37
47
65
86
117
144
176
224
278
325
375
435
521
602
702
812
938
20
27
36
46
64
85
114
141
178
225
271
322
372
427
514
591
709
821
956
—
—
—
—
—
67
91
111
136
174
216
253
291
339
407
472
557
652
765
15
21
28
36
48
64
86
105
127
160
197
229
262
302
358
410
474
544
621
16
21
27
34
48
63
83
103
128
161
192
226
260
296
352
402
477
546
630
—
—
—
—
—
50
66
81
99
124
153
178
203
235
280
322
376
437
507
Conductor size 2mm
Current-carrying capacity, A
CABLE TYPE:
INSULATION TYPE:
MAXIMUM CONDUCTOR TEMPERATURE:
REFERENCE AMBIENT TEMPERATURE:
SINGLE-CORE
XLPE
90°C
40°C IN AIR, 25°C IN GROUND
Stranded/Solid
Enclosed Thermal insulation Buried direct Underground wiring enclosure
CU CU
Flexible AL AL Stranded/Solid Flexible AL
1.5
2.5
4
6
10
16
25
35
50
70
95
120
150
185
240
300
400
500
630
18
25
33
42
56
72
97
120
143
183
220
261
295
335
399
469
534
633
714
19
24
31
41
55
73
94
118
144
183
214
256
291
334
391
458
533
630
719
—
—
—
—
—
56
75
93
111
142
171
203
229
261
312
368
424
509
583
15
20
26
34
45
58
77
96
114
146
176
209
236
268
320
375
427
506
571
—
—
—
—
—
45
60
75
89
114
137
162
183
209
250
294
339
407
466
—
—
—
—
—
28
38
46
—
—
—
—
—
—
—
—
—
—
—
22
31
40
50
67
117
151
180
214
262
313
356
400
452
523
589
668
752
843
22
31
40
50
67
86
113
137
163
203
244
284
320
363
426
491
557
648
727
23
30
38
49
66
85
109
134
163
203
237
279
316
357
416
479
554
642
729
—
—
—
—
—
66
87
106
126
158
190
221
249
283
333
385
442
520
593
CU AL AL AL CU CU CU
10
14
19
24
32
43
58
72
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
91
117
140
166
203
243
277
310
352
409
463
530
604
688
27
38
49
60
79
101
132
158
190
232
276
320
358
413
477
552
626
707
820
—
—
—
—
—
79
103
122
147
180
214
248
277
321
371
430
491
559
654
1. Applies to non-armoured, sheathed or unsheathed cables.
2. Air and concrete slab ambient temperature: 40
3. Soil ambient temperature: 25
4. Depth of laying: 0.5m
5. Thermal resistivity of the soil: 1.2℃.m/W
Notes: 1. Applies to non-armoured, sheathed or unsheathed cables.
2. Air and concrete slab ambient temperature: 40
3. Soil ambient temperature: 25
4. Depth of laying: 0.5m
5. Thermal resistivity of the soil: 1.2℃.m/W
Notes:
Wiring enclosure in air Partially surroundedby thermal insulation
Completely surrounded by thermal insulation
3837 Low Voltage Power CableLow Voltage Power Cable
Current-carrying Capacities
Conductor size 2mm
Current-carrying capacity, A
Unenclosed
CABLE TYPE:
INSULATION TYPE:
MAXIMUM CONDUCTOR TEMPERATURE:
REFERENCE AMBIENT TEMPERATURE:
TWO-CORE SHEATHED
PVC
70°C
40°C IN AIR, 25°C IN GROUND
Stranded/Solid
Space Touching Exposed to sun
Exposed to sun
CU CU CU CU
Flexible AL Stranded/Solid Flexible AL Stranded/Solid Flexible AL Stranded/Solid Flexible AL
1.5
2.5
4
6
10
16
25
35
50
70
95
120
150
185
240
300
400
19
27
37
46
64
85
113
139
170
215
265
307
351
403
477
547
631
20
26
35
45
63
83
110
137
171
215
257
304
348
395
470
537
636
—
—
—
—
—
66
88
108
132
167
205
239
272
314
373
429
500
18
26
34
44
60
80
107
131
159
201
248
288
328
377
446
511
589
18
25
33
42
59
78
104
128
161
202
241
285
326
370
439
502
593
—
—
—
—
—
62
83
101
124
156
192
224
255
294
349
401
467
14
20
27
34
46
60
79
97
116
145
175
202
227
258
300
339
384
14
19
26
32
45
59
77
94
117
145
170
199
225
252
294
331
384
—
—
—
—
—
47
62
75
90
112
136
157
177
201
235
266
305
16
23
30
39
52
68
90
112
133
170
204
241
271
313
364
424
482
17
23
29
38
51
68
87
109
134
169
198
236
267
305
368
415
500
—
—
—
—
—
52
70
87
103
132
158
187
210
244
285
333
383
Conductor size 2mm
Current-carrying capacity, A
CABLE TYPE:
INSULATION TYPE:
MAXIMUM CONDUCTOR TEMPERATURE:
REFERENCE AMBIENT TEMPERATURE:
SINGLE-CORE
XLPE
90°C
40°C IN AIR, 25°C IN GROUND
Thermal insulation Buried direct Underground wiring enclosure
1. Applies to cables with or without earth core, armoured or unarmoured, including neutral screened cables.
2. Air and concrete slab ambient temperature: 40
3. Soil ambient temperature: 25
4. Depth of laying: 0.5m
5. Thermal resistivity of the soil: 1.2℃.m/W
Notes:
Partially surrounded by thermal insulation, in a wiring enclosure
Enclosed
CU
AL Stranded/Solid Flexible AL
1.5
2.5
4
6
10
16
25
35
50
70
95
120
150
185
240
300
400
—
—
—
—
—
49
66
81
99
125
154
179
204
235
279
321
373
14
20
27
35
48
64
85
105
127
161
198
230
263
302
357
409
471
13
19
24
31
42
54
72
90
107
136
163
192
217
250
291
340
386
—
—
—
—
—
42
56
70
83
105
127
150
168
195
228
266
306
9
13
17
22
30
40
53
65
—
—
—
—
—
—
—
—
—
8
12
15
20
26
34
45
56
—
—
—
—
—
—
—
—
—
—
—
—
—
—
26
35
43
—
—
—
—
—
—
—
—
—
21
30
39
50
66
86
112
136
162
202
243
282
317
363
421
483
548
22
29
38
48
65
85
108
133
163
202
236
277
313
353
419
472
560
—
—
—
—
—
66
87
106
126
157
189
220
246
283
329
379
434
CU AL AL CU CU
—
—
—
—
—
31
41
51
—
—
—
—
—
—
—
—
—
21
30
39
50
66
114
147
178
211
259
311
355
398
449
520
586
663
1. Applies to cables with or without earth core, armoured or unarmoured, including neutral screened cables.
2. Air and concrete slab ambient temperature: 40
3. Soil ambient temperature: 25
4. Depth of laying: 0.5m
5. Thermal resistivity of the soil: 1.2℃.m/W
Notes:
AL CU CU AL
—
—
—
—
—
88
114
138
163
201
241
276
309
350
406
460
526
Partially surrounded by thermal insulation, unenclosed
Completely surrounded by thermal insulation, unenclosed
Completely surrounded by thermal insulation, in a wiring enclosure
4039 Low Voltage Power CableLow Voltage Power Cable
Current-carrying Capacities
Conductor size 2mm
Current-carrying capacity, A
Unenclosed
CABLE TYPE:
INSULATION TYPE:
MAXIMUM CONDUCTOR TEMPERATURE:
REFERENCE AMBIENT TEMPERATURE:
TWO-CORE SHEATHED
PVC
70°C
40°C IN AIR, 25°C IN GROUND
Stranded/Solid
Space Touching Exposed to sun
Exposed to sun
CU CU CU CU
Flexible AL Stranded/Solid Flexible AL Stranded/Solid Flexible AL Stranded/Solid Flexible AL
1.5
2.5
4
6
10
16
25
35
50
70
95
120
150
185
240
300
400
24
34
45
57
78
104
140
173
211
268
331
385
441
509
604
694
804
24
32
43
55
78
103
136
169
213
269
322
381
438
499
596
682
811
—
—
—
—
—
81
109
134
163
208
257
299
342
396
472
544
636
22
31
42
53
73
97
131
162
197
250
309
359
411
473
562
645
745
23
30
40
51
72
96
128
158
199
251
300
355
408
464
554
633
751
—
—
—
—
—
75
102
125
153
194
239
279
319
369
439
505
590
19
27
36
46
63
83
111
136
165
208
255
295
336
385
454
518
594
20
26
35
44
62
82
108
134
167
209
248
292
333
377
446
507
597
—
—
—
—
—
64
86
106
128
162
198
230
261
300
354
406
470
20
28
37
46
63
82
110
132
162
200
250
285
332
377
448
523
596
20
27
35
44
62
80
106
129
163
207
242
289
328
375
439
511
595
—
—
—
—
—
63
85
102
126
155
194
222
257
293
350
410
472
Conductor size 2mm
Current-carrying capacity, A
CABLE TYPE:
INSULATION TYPE:
MAXIMUM CONDUCTOR TEMPERATURE:
REFERENCE AMBIENT TEMPERATURE:
SINGLE-CORE
XLPE
90°C
40°C IN AIR, 25°C IN GROUND
Thermal insulation Buried direct Underground wiring enclosure
1. Applies to cables with or without earth core, armoured or unarmoured, including neutral screened cables.
2. Air and concrete slab ambient temperature: 40
3. Soil ambient temperature: 25
4. Depth of laying: 0.5m
5. Thermal resistivity of the soil: 1.2℃.m/W
Notes:
Partially surrounded by thermal insulation, in a wiring enclosure
Enclosed
CU
AL Stranded/Solid Flexible AL
1.5
2.5
4
6
10
16
25
35
50
70
95
120
150
185
240
300
400
—
—
—
—
—
60
81
100
122
155
192
223
255
295
351
404
472
18
25
33
42
58
78
105
129
158
200
247
287
328
379
449
516
596
16
23
29
37
51
66
88
106
130
160
200
228
265
301
358
418
477
—
—
—
—
—
51
68
82
101
124
155
177
206
235
280
328
378
11
16
21
27
36
49
66
81
—
—
—
—
—
—
—
—
—
10
14
18
23
32
41
55
66
—
—
—
—
—
—
—
—
—
—
—
—
—
—
32
43
51
—
—
—
—
—
—
—
—
—
24
34
45
56
75
98
128
154
185
228
279
318
365
413
485
558
633
25
33
43
54
74
95
124
150
186
231
271
318
360
407
475
544
631
—
—
—
—
—
75
99
119
144
177
216
247
283
322
379
437
501
CU AL AL CU CU
—
—
—
—
—
38
51
63
—
—
—
—
—
—
—
—
—
24
34
45
56
75
132
170
205
244
300
360
410
460
520
603
680
771
1. Applies to cables with or without earth core, armoured or unarmoured, including neutral screened cables.
2. Air and concrete slab ambient temperature: 40
3. Soil ambient temperature: 25
4. Depth of laying: 0.5m
5. Thermal resistivity of the soil: 1.2℃.m/W
Notes:
AL CU CU AL
—
—
—
—
—
102
132
159
189
233
279
319
357
405
471
533
610
Partially surrounded by thermal insulation, unenclosed
Completely surrounded by thermal insulation, unenclosed
Completely surrounded by thermal insulation, in a wiring enclosure
4241 Low Voltage Power CableLow Voltage Power Cable
Current-carrying Capacities
Conductor size 2mm
Current-carrying capacity, A
Unenclosed
CABLE TYPE:
INSULATION TYPE:
MAXIMUM CONDUCTOR TEMPERATURE:
REFERENCE AMBIENT TEMPERATURE:
THREE-CORE TO FIVE-CORE SHEATHED
PVC
70°C
40°C IN AIR, 25°C IN GROUND
Stranded/Solid
Space Touching Exposed to sun
Exposed to sun
CU CU CU CU
Flexible AL Stranded/Solid Flexible AL Stranded/Solid Flexible AL Stranded/Solid Flexible AL
1.5
2.5
4
6
10
16
25
35
50
70
95
120
150
185
240
300
400
16
23
31
40
54
72
97
120
146
185
228
265
303
348
412
472
544
17
22
30
38
54
71
94
117
148
185
222
262
301
342
407
464
549
—
—
—
—
—
56
75
93
113
143
177
206
235
272
323
372
434
15
22
29
37
51
68
91
112
137
172
213
247
282
324
383
438
504
16
21
28
36
51
67
89
110
138
173
207
244
280
318
378
430
508
—
—
—
—
—
53
71
87
106
134
165
192
219
253
301
345
402
12
17
23
29
39
51
67
82
99
123
150
172
194
220
256
288
326
12
16
22
28
38
50
65
80
100
123
145
169
192
215
251
282
326
—
—
—
—
—
40
52
64
77
96
116
134
151
172
200
227
260
14
20
25
33
44
58
76
94
112
142
177
202
228
263
316
—
—
14
19
24
32
43
57
73
92
112
142
172
199
229
257
309
—
—
—
—
—
—
—
45
59
73
87
111
137
157
177
206
248
—
—
Conductor size 2mm
CABLE TYPE:
INSULATION TYPE:
MAXIMUM CONDUCTOR TEMPERATURE:
REFERENCE AMBIENT TEMPERATURE:
THREE-CORE TO FIVE-CORE SHEATHED
PVC
70°C
40°C IN AIR, 25°C IN GROUND
Thermal insulation Buried direct Underground wiring enclosure
1. Applies to cables with or without earth core, armoured or unarmoured, including neutral screened cables.
2. Air and concrete slab ambient temperature: 40
3. Soil ambient temperature: 25
4. Depth of laying: 0.5m
5. Thermal resistivity of the soil: 1.2℃.m/W
Notes:
Partially surrounded by thermal insulation, in a wiring enclosure
Enclosed
CU
AL Stranded/Solid Flexible AL
1.5
2.5
4
6
10
16
25
35
50
70
95
120
150
185
240
300
400
—
—
—
—
—
42
57
69
85
107
132
154
175
203
240
—
—
12
17
23
30
41
54
73
90
109
138
170
198
226
259
307
—
—
11
16
20
26
35
47
60
75
89
114
142
162
182
211
253
—
—
—
—
—
—
—
36
47
58
69
88
110
126
142
165
198
—
—
8
11
15
19
25
34
46
56
—
—
—
—
—
—
—
—
—
7
10
13
16
22
29
38
47
—
—
—
—
—
—
—
—
—
—
—
—
—
—
23
29
36
—
—
—
—
—
—
—
—
—
18
25
33
42
55
73
94
114
136
170
208
237
266
304
359
404
468
18
24
32
40
54
71
91
112
137
169
201
232
265
296
351
394
467
—
—
—
—
—
56
73
89
105
132
161
184
207
237
281
318
374
CU AL AL CU CU
—
—
—
—
—
26
35
43
—
—
—
—
—
—
—
—
—
18
25
33
42
55
96
125
150
178
219
263
300
336
379
438
493
557
1. Applies to cables with or without earth core, armoured or unarmoured, including neutral screened cables.
2. Air and concrete slab ambient temperature: 40
3. Soil ambient temperature: 25
4. Depth of laying: 0.5m
5. Thermal resistivity of the soil: 1.2℃.m/W
Notes:
AL CU CU AL
—
—
—
—
—
75
97
117
138
170
204
233
261
296
344
388
444
Partially surrounded by thermal insulation, unenclosed
Completely surrounded by thermal insulation, unenclosed
Completely surrounded by thermal insulation, in a wiring enclosure
4443 Low Voltage Power CableLow Voltage Power Cable
Current-carrying Capacities
Conductor size 2mm
Current-carrying capacity, A
Unenclosed
CABLE TYPE:
INSULATION TYPE:
MAXIMUM CONDUCTOR TEMPERATURE:
REFERENCE AMBIENT TEMPERATURE:
THREE-CORE TO FIVE-CORE SHEATHED
PVC
70°C
40°C IN AIR, 25°C IN GROUND
Stranded/Solid
Space Touching Exposed to sun
Exposed to sun
CU CU CU CU
Flexible AL Stranded/Solid Flexible AL Stranded/Solid Flexible AL Stranded/Solid Flexible AL
1.5
2.5
4
6
10
16
25
35
50
70
95
120
150
185
240
300
400
20
28
38
48
66
88
119
147
180
229
283
330
377
436
517
594
685
20
27
36
46
66
87
116
144
182
230
275
327
375
428
511
584
692
—
—
—
—
—
68
93
114
140
178
220
256
293
340
405
467
546
19
26
35
45
62
83
111
137
168
213
263
306
350
404
479
549
632
19
26
34
43
61
81
108
135
170
214
256
303
348
396
472
539
638
—
—
—
—
—
64
86
106
130
165
204
238
272
315
375
432
504
16
23
30
39
53
70
94
115
140
177
217
251
285
327
385
439
502
17
22
29
37
52
69
92
113
142
177
211
248
283
320
379
430
504
—
—
—
—
—
54
73
89
109
137
168
195
222
255
302
345
400
16
24
30
38
53
68
91
114
136
173
209
246
277
322
386
—
—
17
23
29
37
52
67
89
111
136
173
202
242
274
314
379
—
—
—
—
—
—
—
53
71
88
105
134
162
192
216
251
303
—
—
Conductor size 2mm
CABLE TYPE:
INSULATION TYPE:
MAXIMUM CONDUCTOR TEMPERATURE:
REFERENCE AMBIENT TEMPERATURE:
THREE-CORE TO FIVE-CORE SHEATHED
XLPE
90°C
40°C IN AIR, 25°C IN GROUND
Thermal insulation Buried direct Underground wiring enclosure
1. Applies to cables with or without earth core, armoured or unarmoured, including neutral screened cables.
2. Air and concrete slab ambient temperature: 40
3. Soil ambient temperature: 25
4. Depth of laying: 0.5m
5. Thermal resistivity of the soil: 1.2℃.m/W
Notes:
Partially surrounded by thermal insulation, in a wiring enclosure
Enclosed
CU
AL Stranded/Solid Flexible AL
1.5
2.5
4
6
10
16
25
35
50
70
95
120
150
185
240
300
400
—
—
—
—
—
51
69
85
104
132
163
190
218
252
300
—
—
15
21
28
36
49
66
89
110
134
170
210
245
280
323
383
—
—
13
19
24
30
42
55
73
91
108
138
167
197
222
257
309
—
—
—
—
—
—
—
42
57
71
84
107
129
153
172
201
242
—
—
9
13
18
22
31
41
56
69
—
—
—
—
—
—
—
—
—
8
12
15
19
26
34
46
57
—
—
—
—
—
—
—
—
—
—
—
—
—
—
26
36
44
—
—
—
—
—
—
—
—
—
20
29
37
46
63
81
107
130
155
193
233
270
304
348
411
463
524
21
28
36
45
62
79
103
127
155
193
226
266
300
339
402
452
537
—
—
—
—
—
63
83
101
120
150
181
210
236
272
322
365
417
CU AL AL CU CU
—
—
—
—
—
32
43
53
—
—
—
—
—
—
—
—
—
20
29
37
46
63
110
143
172
204
251
302
344
385
435
504
567
640
1. Applies to cables with or without earth core, armoured or unarmoured, including neutral screened cables.
2. Air and concrete slab ambient temperature: 40
3. Soil ambient temperature: 25
4. Depth of laying: 0.5m
5. Thermal resistivity of the soil: 1.2℃.m/W
Notes:
AL CU CU AL
—
—
—
—
—
85
111
133
159
195
234
267
299
340
395
446
510
Partially surrounded by thermal insulation, unenclosed
Completely surrounded by thermal insulation, unenclosed
Completely surrounded by thermal insulation, in a wiring enclosure
4645 Low Voltage Power CableLow Voltage Power Cable