low voltage airguard - power prysmian airguard.pdf · w i re & cable, i nc. low voltage...

2

Upload: others

Post on 19-Aug-2020

3 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: LOW VOLTAGE AIRGUARD - POWER Prysmian Airguard.pdf · W I RE & CABLE, I NC. LOW VOLTAGE AIRGUARD -VFD Product Numberaind lnwla,tlon Nvmbctr&Sile Nomln,11 Nomini-1 Nominal M,ntmum

LOW VOLTAGE AIRGUARD - POWER

WWW.PRIORITYWIRE.COM

Page 2: LOW VOLTAGE AIRGUARD - POWER Prysmian Airguard.pdf · W I RE & CABLE, I NC. LOW VOLTAGE AIRGUARD -VFD Product Numberaind lnwla,tlon Nvmbctr&Sile Nomln,11 Nomini-1 Nominal M,ntmum

W I RE & CABLE, I NC.

LOW VOLTAGE AIRGUARD -VFD Product Numberaind lnwla,tlon Nvmbctr&Sile Nomln,11 Nomini-1 Nominal M,ntmum Number Circuit Conductor Thickness of Groundlng J1eket OveraJI Coble ~ndlng

Site Condutot'(s) ThicknHs Clblf!OD Wtio:ht Radius Mils #•AWG Mils Inches lbs/Mft Inches

14·03AIRGUAR0-0$ 3/C#14AWG 30 3 • 18 80 0.630 2$-0 7.S 12•03AIRGUARD•OS 3/C#l2AWG 30 3• 16 80 0.670 300 8.1 J0-03AIRGUAR0-05 3/C#IOAWG 30 3· 14 80 o.ns 370 8.7

8-03AIRGUARO-OS 3/C#S AWG 45 3-14 80 0.905 550 10.9 6-03AIRGUAR0-0$ 3/C#6AWG 4$ 3· ll 80 o.m 700 11.9 •4-03AIRGUARO-OS 3/C#4AWG 45 3-12 80 1.095 900 13.2 •2-03AJRGUAR0-0S 3/C#lAWG 4$ 3-10 80 t.llS ll40 14.7

• 1/0•0lAlRGUAA0-05 3/CI/OAWG 5S 3-10 80 1.445 1720 17.3 •2J0-03A1RGUAAO-OS 3/Cl/OAWG ss 3-10 80 ).$40 2170 18.S • 3/0•03AIRGUAAO-OS 3/C3/0AWG ss 3 • 8 80 1.640 2644 12.0 •4/0·03A1RGUAA0-05 3/C4/0AWG ss 3-8 80 1.830 3193 13.0 ·2so-03AIRGUARD•OS 3/C2SOAWG 65 3 • 8 110 1.980 3846 14.0 •350-03AIRGUAR0-0$ 3/C350AWG 65 3.5 llO l.l20 S-070 16.0 •soo-o3AIRGUARD•OS 3/CSOOAWG 6S 3-5 110 2.530 6863 18.0 •JS0-03AIRGUARO-OS 3/C750AWG 80 3.5 110 3 .020 10518 22.0

PrOduct Notts:

i Per 2014 NECTA8t.E 310.15{8)(16> "'Allowable AmpacitSes of Insulated Conductors R"ted up to and including 2000 Vott.s, GO•c through WC (140-F through 194"F), Not Mort Than Three Current-carl'yin& conductors"'

•c.tblH not m;,rked "·Hl• (per UL 222$, over.)11 (:.)bJe diameter mun be 1.00 in(h or le.s.s to be marked •·HL ") ••An vatue-s are nominal and subject to change al Mytime without notke

Ampacity Gla,nd IAm0$) &plosion Proof

ClDl

+/·90C

lS PWC•4l48T03

30 PWC•4248T03

40 PWC-4l48T03

55 PWC-4248104

75 PWC-4l48l04

95 PWC-4248T15 130 PWC-4l48T!S 170 PWC•4248T06

19S PWC-4l48l06

22S . l60 PWC-4l48T07

290 PWC•4248T07

350 PWC-4l48T08 430 PWC,4248109 535 .

Prysmlan's tow Voltage AJRGUARO"' Power ~bl~ are primarily designed fo, applkatloo-s Int.he harsh environments found In the heavy Industrial and offsho,e markets. Its rugged polymeric AIRBAG"" armor and chemical barNef protection pactage makes It the ideal cable choice for tough harsh environmental conditions. AIRGUMO'" provides. the ,otution to the dcfiQi()'nCie, ohto tncountcrcd with MC•Hl C'b't-S inclvdins armQf brt:lkMe cneou11tcrcd during insu1113tion a,nd in .lJ)plic31iOM r<tquiriRB rtcurting ben4ing .lft<tr inu;,tl;itiOn, lt$ wd l as P00f" pcrlo1manct in ,lrC4$ of high vibr:ilion (t.g, motor (OMC<tiOns). It ;ilso p,ovidcs • s:aftt and 10\\~t in$t3l1Cd CO$l cost aftemat!Ve to MC·HL cables d'!Jt to faster ... No Knife/ Ho SaW"' cab~ preparation and substantially reduced cost of c.able gtaOOs.

lowVott~e A!RGUAR.OVFOcabfes are designed with three symmetrically placed ground wlres and an ahJminum or copper sheath to contain the generation hig:h frequency electromagnetic interference (EMI) imposed on the cable when installed in a circuit containing a Variable frequeflC'( Drive. In the event of catastrophic cable d,1m:isc, this sl'litld, plus the 3 sc:-gment~ gr01,1nd wirts, $.hOIJ)d contain any arcing and effC(lfYtly c.onduCI system f:,1,111 cuncnt 10 ground.

Lc>wVolta,geAIRGUARO"' is ~ted fr,, insunations. In cat>Jc tr~y for eKposed r1,1ns (Typo TC•ER), «>ndr.iit, 3n4dir«t bu1i~I. tt ('KClted5 the $1rii,stnt crush 3nd im~ct reffltance of UL 222S for MC-tu cables and Is pe,tmltted for use In aass I OlvlslOt\ J and Zone 1 ha1ardous locat1ons (TC-ER·Hl) In accotdance with National Elec1,ical Code (2014) Sections S01.10(A)(2)(3) and 50S,1S(8)(i}, Prysmian's patented AIR.GUARD,.. design affords faf greater protection agains.t water ingress. and chemical att.Kk than traditional MC Armored Cable-s.. It also pcovides users tM ease of Installation of a tr,y c:ablewhile prOYidirtS better mechanical and environmental protection than tr:id'itio~J met,lJ d~d table,$

SPECIFICATIONS ASTM 83 & ASTM B8 K:EAS-82-SSS (NEMA WC70) UL 44 (l<HHW-2) 600V UL 1202/FT-4

UL 1277 NECArtlde 336.10(7}

UL222S NEC Article S01. lOIA)(2)(3) NEC Article SOS, lSIB)(l)(i) CSA 22.2 Ho. 03 MSHA

Class 8 Soft Drawn concenuic lay Stranded Bate Coppe,r conductors Cable Rating XHHW-2 Multiple Conductors • Direct &Jrled • Sunlight Resistant • Oil Resistant Fl3me Rettrdo\n1

TC,ER ExPosc4 Run Rt lin&

TC-ER· HL TC-ER· HL Cl.ass I Division 1

lCER-tlt Class I Zone l -40C/ · 35C Cold Bend/Cold Impact Min(I ~ftty & Hcollh Administr.ition

In U.S. 1-800-945-5542

WWW.PRIORITYWIRE.COM