Page 1: Low Temperature Corrosion in a Waste Fired Boiler€¦ · Low Temperature Corrosion in a Waste Fired Boiler. Dr.ir. Kenneth Villani. Dr.ir. Johan De Greef. Introduction . Åmotfors

www.keppelseghers.com

Low Temperature Corrosion in a Waste Fired Boiler

Dr.ir. Kenneth VillaniDr.ir. Johan De Greef

Page 2: Low Temperature Corrosion in a Waste Fired Boiler€¦ · Low Temperature Corrosion in a Waste Fired Boiler. Dr.ir. Kenneth Villani. Dr.ir. Johan De Greef. Introduction . Åmotfors

IntroductionÅmotfors

Energi

AB

VarmlandSweden

First fire 12/02/2010

27,4 MWth10 t/h waste throughput

Page 3: Low Temperature Corrosion in a Waste Fired Boiler€¦ · Low Temperature Corrosion in a Waste Fired Boiler. Dr.ir. Kenneth Villani. Dr.ir. Johan De Greef. Introduction . Åmotfors

Sludge treatment

Sludge drying/pelletising/

incineration

Sludge digestion

HARDPELLETISER HARDPELLETISER ZEROFUELZEROFUELTMTM

Solid Waste

Waste pre-treatment

DANODANO®® drumdrum

Waste-to-Energy Air Pollution Control

WasteWaste--toto--energy plantenergy plant

Wastewater treatment

• Process- & Drinking water treatment• Desalination

CAS, UNITANK CAS, UNITANK ®® & UNIBRANE & UNIBRANE ®®

NEWATER / MEMSTILLNEWATER / MEMSTILL®®

Water treatment

Introduction

For energy recuperationFor energy recuperation

Page 4: Low Temperature Corrosion in a Waste Fired Boiler€¦ · Low Temperature Corrosion in a Waste Fired Boiler. Dr.ir. Kenneth Villani. Dr.ir. Johan De Greef. Introduction . Åmotfors

NextGenBioWaste-project

WP 2.6 : Ecoprobe

Life test ofAcid Dewpointin a WtE

plant

SP 2 -

Boiler Optimisation

Page 5: Low Temperature Corrosion in a Waste Fired Boiler€¦ · Low Temperature Corrosion in a Waste Fired Boiler. Dr.ir. Kenneth Villani. Dr.ir. Johan De Greef. Introduction . Åmotfors

Basics: Acid Dewpoint

SO2 (g) + ½ O2 (g)→ SO3 (g)

SO3 (g) + H2 O (g) → H2 SO4 (g)

• Presence of catalyst• Fly ash as absorber• Soot as condensation site• Excess air conditions• Water content• Temperature

ADT = Acid Dewpoint Temperature

[ Blanco J.M. and Pena F., Appl. Ther. Eng (2007)

H2 SO4 (g) →

H2 SO4 (l)T < ADT

Page 6: Low Temperature Corrosion in a Waste Fired Boiler€¦ · Low Temperature Corrosion in a Waste Fired Boiler. Dr.ir. Kenneth Villani. Dr.ir. Johan De Greef. Introduction . Åmotfors

ObjectivesGoals

- Collection of plant-scale data on acid dewpoint corrosion at the exit of a WtE-boiler

- Experimental assessment of risk on acid dewpoint corrosion

Ultimate aimOptimisation of WtE-boiler design by reducing excessive safety margins on :

• BFW-temperature• Flue Gas temperature

Increase efficiency - increase operational revenue

Page 7: Low Temperature Corrosion in a Waste Fired Boiler€¦ · Low Temperature Corrosion in a Waste Fired Boiler. Dr.ir. Kenneth Villani. Dr.ir. Johan De Greef. Introduction . Åmotfors

ObjectivesSimulation - potential electrical efficiency gain

Page 8: Low Temperature Corrosion in a Waste Fired Boiler€¦ · Low Temperature Corrosion in a Waste Fired Boiler. Dr.ir. Kenneth Villani. Dr.ir. Johan De Greef. Introduction . Åmotfors

Approach

• Insert water-cooled probe of economiser material (ST45.8) in end boiler near economizer section

• Observe corrosion phenomena (s.a. type, depth, intensity, …) at various temperatures for 60 days

How ?

Page 9: Low Temperature Corrosion in a Waste Fired Boiler€¦ · Low Temperature Corrosion in a Waste Fired Boiler. Dr.ir. Kenneth Villani. Dr.ir. Johan De Greef. Introduction . Åmotfors

Ecoprobe

Boiler wall

HCl

SO2

H2 O

SO3O2

CO2

and many other …

ashes

Probe

Metalssoot

Page 10: Low Temperature Corrosion in a Waste Fired Boiler€¦ · Low Temperature Corrosion in a Waste Fired Boiler. Dr.ir. Kenneth Villani. Dr.ir. Johan De Greef. Introduction . Åmotfors

Set-up

Experimental set-up

aerotherm

T

TT

Tpump

Expansion vessel

Boiler w

all

3-wayvalve

PROBE

heater

Page 11: Low Temperature Corrosion in a Waste Fired Boiler€¦ · Low Temperature Corrosion in a Waste Fired Boiler. Dr.ir. Kenneth Villani. Dr.ir. Johan De Greef. Introduction . Åmotfors

Client: ISVAG

Capacity: 2 x 288 tonnes/day

Calorific value: 8 MJ/kg

Thermal power: 2 x 28 MWth

Electrical power: 12 MWe

Flue gas treatment: SNCR + ESP + semi

dry + AC injection + fabric filter + wet

Capacity: 2 x 65,000 Nm³/h

Start-up: 1999

Experiment Location

Antwerpen-Wilrijk (Flanders)

Page 12: Low Temperature Corrosion in a Waste Fired Boiler€¦ · Low Temperature Corrosion in a Waste Fired Boiler. Dr.ir. Kenneth Villani. Dr.ir. Johan De Greef. Introduction . Åmotfors

Range of Measurement

Plant data ISVAG:

Flue gas flow 56 000 Nm³/hO2 6 - 8 Vol. %H2 O 12 - 15 Vol. %HCl 600 – 1500 mg/Nm³ 11%O2 drySOx 50 - 350 mg/Nm³ 11%O2 dryT 250 °C

Dewpoint expected between 105 and 120 °C

[Predicting Dew Points of Flue Gases, Verhoff & Banchero, Chem. Eng. Prog. 70, 8, 71-72 (1974)]

Estimation of expected ADT

Page 13: Low Temperature Corrosion in a Waste Fired Boiler€¦ · Low Temperature Corrosion in a Waste Fired Boiler. Dr.ir. Kenneth Villani. Dr.ir. Johan De Greef. Introduction . Åmotfors

60

70

80

90

100

110

120

130

blanc test 1 test 2 test 3 test 4

Tem

pera

ture

[°C

]

Experiments

125105 100

9080

T = 60 days

Page 14: Low Temperature Corrosion in a Waste Fired Boiler€¦ · Low Temperature Corrosion in a Waste Fired Boiler. Dr.ir. Kenneth Villani. Dr.ir. Johan De Greef. Introduction . Åmotfors

Results

T = 0 days

Page 15: Low Temperature Corrosion in a Waste Fired Boiler€¦ · Low Temperature Corrosion in a Waste Fired Boiler. Dr.ir. Kenneth Villani. Dr.ir. Johan De Greef. Introduction . Åmotfors

Results

T = 30 days

Page 16: Low Temperature Corrosion in a Waste Fired Boiler€¦ · Low Temperature Corrosion in a Waste Fired Boiler. Dr.ir. Kenneth Villani. Dr.ir. Johan De Greef. Introduction . Åmotfors

125°C 105°C

100°C 90°C

new80°C

T = 60 days

Page 17: Low Temperature Corrosion in a Waste Fired Boiler€¦ · Low Temperature Corrosion in a Waste Fired Boiler. Dr.ir. Kenneth Villani. Dr.ir. Johan De Greef. Introduction . Åmotfors

ResultsSEM-pictures

Magnitude 200 xNital

surface treatment

(a)

Blanc(b)

90°C

(c)

80°C (a)

(b) (c)

Page 18: Low Temperature Corrosion in a Waste Fired Boiler€¦ · Low Temperature Corrosion in a Waste Fired Boiler. Dr.ir. Kenneth Villani. Dr.ir. Johan De Greef. Introduction . Åmotfors

Results

0

20

40

60

80

100

80 90 100 105 125 130

temperature [°C]

Cor

rosi

on d

epth

[% o

f sec

tion]

new

Page 19: Low Temperature Corrosion in a Waste Fired Boiler€¦ · Low Temperature Corrosion in a Waste Fired Boiler. Dr.ir. Kenneth Villani. Dr.ir. Johan De Greef. Introduction . Åmotfors

125°C 105°C

100°C

80°C

90°C

Cl

SEM/EDAX

Page 20: Low Temperature Corrosion in a Waste Fired Boiler€¦ · Low Temperature Corrosion in a Waste Fired Boiler. Dr.ir. Kenneth Villani. Dr.ir. Johan De Greef. Introduction . Åmotfors

Results overview125 °C1440h

105 °C1440h

100 °C1440h

90 °C1440h

80°C1440h

type Fe2 O3 Fe2 O3 Fe2 O3 Fe2 O3 Fe2 O3

intensity superficial superficial superficial superficial deep – entire section

Depth (mm) 0.4 to 0.6 0.15 0.1 to 0.15 0.2 to 0.35 2.0 to 2.6

decrease thickness tube wall

no no no no no

Cl + + - + +++

S - + - - -

Page 21: Low Temperature Corrosion in a Waste Fired Boiler€¦ · Low Temperature Corrosion in a Waste Fired Boiler. Dr.ir. Kenneth Villani. Dr.ir. Johan De Greef. Introduction . Åmotfors

Summary

• Superficial corrosion at 125, 105, 100 and 90 °C

• No significant difference between 125, 105, 100 and 90°C

• Very intense corrosion at 80°C

• Cl appears to contribute (HCl ?)

Page 22: Low Temperature Corrosion in a Waste Fired Boiler€¦ · Low Temperature Corrosion in a Waste Fired Boiler. Dr.ir. Kenneth Villani. Dr.ir. Johan De Greef. Introduction . Åmotfors

Conclusions

• The onset of low temperature corrosion in a waste fired boiler is situated between 80 and 90°C (FGT 240°C)

• BFW at 105°C represents no corrosion risk

• Room for Energetic/Revenue optimisation

Page 23: Low Temperature Corrosion in a Waste Fired Boiler€¦ · Low Temperature Corrosion in a Waste Fired Boiler. Dr.ir. Kenneth Villani. Dr.ir. Johan De Greef. Introduction . Åmotfors