D180 PN#02081318 / 03.16 / FIL1505-1696
LOW PRESSURE FILTERS
Applications
Industrial Pulp & Paper Steel / HeavyIndustry
Technical SpecificationsMounting Method See drawingsPort Connection 4” SAE DN 102 Flange Code 61
(with M16 bolts included)
Flow Direction2.0 version Inlet: Side Outlet: Side
Construction MaterialsHead, Housing, Lid6” Piping headersElbows, Manifolds
AluminumCarbon SteelDuctile Iron
Flow Capacity DCP… 4” Header Piping5210, 5214, 7810, 7814, 10410, 10414
450 gpm (1700 lpm)
CC7… 6” Header Piping5210, 52147810, 7810, 10410, 10414
900 gpm (3406 lpm)1350 gpm (5110 lpm)
Housing Pressure RatingMax. Allowable Working PressureFatigue PressureBurst Pressure
232 psi (16 bar)232 psi (16 bar)Contact HYDAC
Element Collapse Pressure RatingON,ECON2
290 psid (20 bar)145 psid (10 bar)
Fluid Temperature Range 14°F to 212°F (-10°C to 100°C)Consult HYDAC for applications below 14˚F (-10˚C)
Fluid Compatibility Compatible with all hydrocarbon based, synthetic, water glycol, oil/water emulsion, and high water based fluids when the appropriate seals are selected.
Indicator Trip Pressure∆P = 29 psid (2 bar) -10%∆P = 72 psid (5 bar) -10% 2.0 - Differential
Bypass Valve Cracking Pressure∆P = 14.5 psid (1 bar) +10%∆P = 43 psid (3 bar) +10% (standard)∆P = 87 psid (6 bar) +10%
Features• Less weight/handling - reducing shipping costs• Towers isolated individually
(versus NFD 5210 and up, duty-standby arrangement)• Lower Clean ∆P (less filters, elements, and piping)• Significant Cost Reduction (less components, smaller footprint)• Ease of Operation/Maintenance (less leakage points)• Uses NF Series proven housing and element technology• Replacement Elements - Optimicron®, ECOmicron®-fit,
ECOmicron® (environmentally friendly, incinerable)
ConfigurationsNF Optimicron®, ECOmicron® Size 5210, 7810, 10410• Bypass located in element endcap
NF ECOmicron®-fit Size 5214, 7814, 10414• Bypass separate, replaceable component
NF MMP SeriesManifold Modular Parallel Inline Filters - with ECOmicron®-fit option232 psi • up to 450 gpm (4” header) • up to 1350 gpm (6” header)
Hydraulic Symbol NF 52XX Manifold Modular
NF 104XX Manifold Modular
B←
→A
←B
MODULARNF 52XX MANIFOLD
MODULARNF 104XX MANIFOLD
A→
B←
→A
←B
MODULARNF 52XX MANIFOLD
MODULARNF 104XX MANIFOLD
A→
D181PN#02081318 / 03.16 / FIL1505-1696
LOW PRESSURE FILTERSModel Code
NF ON 5210 C C P 6 D 2.0 / A V B6 EM - DBVFilter Type NF = Inline Filter
Element Media ON = Optimicron®
ECON2 = ECOmicron®, ECOmicron®-fit
Size 5210, 7810, 10410 = ON, ECON2 5214, 7814, 10414 = ECON2 (ECOmicron-fit)
Operating Pressure C = 232 psi (16 bar)
Type of Isolation Valve C = Butterfly valves upstream and downstream
Type of Connection P = SAE DN 102 (4”) Flange - Code 61 7 = 6” ANSI CS 300lb. Flange
Filtration Rating (micron) 1, 3, 5, 10, 15, 20 = ON 3, 5, 10, 20 = ECON2 3, 6, 12, 25 = ECON2 (ECOmicron-fit)
Type of ∆P Clogging Indicator A = No Indicator (plugged) B, BM, C, D, LE (Others available upon request)
Type Number / Modification Number 2.0 = Inline Filter - ∆P indicator
Flow Path (facing Inlet manifold headers) A = Left inlet, Left outlet C = Left inlet, Right outlet B = Right inlet, Right outlet D = Right inlet, Left outlet
Seals (omit) = Nitrile rubber (NBR) (standard) V = Fluorocarbon elastomer (FKM) EPR = Ethylene propylene rubber (EPR)
Bypass Valve (omit) = 43 psid (3 bar) (standard) B1 = 14.5 psid (1 bar) (lube or coolant) B6 = 87 psid (6 bar) (return line extended life)
not available with ECON2
KB = no bypass (flushing system)
Supplementary Details SO263 = Modification of ON and W/HC elements for Skydrol or HYJET phosphate ester fluids L24, L48, L110, L220 = Lamp for D-type clogging indicator (LXX, XX = voltage) SFREE = Element specially designed to minimize electrostatic charge generation EM = Manual vent valve set VKD = Drain manifold DBV = Double butterfly valve (standard) DBVL = Double butterfly valve - lockable cRUus = Electrical Indicator with underwriter’s recognition
Model Codes Containing RED are non-stock items — Minimum quantities may apply – Contact HYDAC for information and availability
Replacement Element Model Code (ON, ECON2)
2600 R 005 ON / V B6 . Size 2600
Filtration Rating (micron) 1, 3, 5, 10, 15, 20 = ON 3, 5, 10, 20 = ECON2
Element Media ON, ECON2
Seals (omit) = Nitrile rubber (NBR) (standard) V = Fluorocarbon elastomer (FKM) EPR = Ethylene Propylene rubber (EPDM)
Bypass Valve (omit) = 43 psid (3 bar) (standard) B1 = 14.5 psid (1 bar) B6 = 87 psid (6 bar) KB = no bypass
Supplementary Details SO263 = (See above) SFREE = (See above)
Replacement Element Model Code (ECOmicron-fit)
1.14.39D 6 ECON2 - V. Size 1.14.39D
Filtration Rating (micron) 3, 6, 12, 25 = ECON2
Element Media ECON2
Seals (omit) = Nitrile rubber (NBR) (standard) V = Fluorocarbon elastomer (FKM)
Clogging Indicator Model CodeVM 5 BM . X / .
Indicator Prefix VM = ∆P, G 1/2” 3000 psi VD = ∆P G 1/2” 6000 psi
(2.0 ver. - LE Indicators only)Trip Pressure 2 = 29 psid (2 bar) (return filters) 5 = 72 psid (5 bar) (optional)
Type of Indicator A = No indicator, plugged port BM = Pop-up indicator (manual reset) C = Electric switch - SPDT D = Electric switch and LED light - SPDT LE = Electric switch and pop-upModification NumberSupplementary Details Seals (omit) = Nitrile rubber (NBR) (standard) V = Fluorocarbon elastomer (FKM) EPR = Ethylene Propylene rubber (EPDM) Light Voltage (D type indicators only) L24 = 24V L110 = 110V Thermal Lockout (VM type C, D, J, J4 only) T100 = Lockout below 100˚F Underwriter’s Approval (VM type C, D, J, J4 only) cRUus = Electrical Indicator with underwriter’s recognition
(For additional details and options, see Section G - Clogging Indicators.)
D182 PN#02081318 / 03.16 / FIL1505-1696
LOW PRESSURE FILTERS
Size 5210
Weight (lbs.) 287
Dimensions shown are [inches] millimeters for general information and overall envelope size only. Weights listed include element. For complete dimensions please contact HYDAC to request a certified print.
Dimensions NF 5210 2.0 Version (Modular Parallel)
60.081526
52.681338
OUTLET
4" Flange
SAE DN100
SAE DN100
manifold
4" Flange
OUTLETIsolation valve
INLETIsolation valve
INLET
Drain
(Option)
Manual ventvalves Option
G 1/2" ports2 places
Dirty side drain portG 1/2"
25.66652
7.87200
for element removal
G 1/2"
2 places
[36.02]
2 places
915Clearance required
P Clogging indicatorport ∆
port G 3/4"
Filling connection
Connection for staticclogging indicator
G 1/2"2 places
19Thru
0.75
3.06 77.8
5.12130Bolt
Spacing
3.94100 335.5
13.21
452.3 17.81
405.5
8 places
15.96
10.24260
Lid Top
Mounting pattern
120 4.72
11.81300
0.5514
Thru4 Places
716 28.18
23.32592.3
11.81300
D183PN#02081318 / 03.16 / FIL1505-1696
LOW PRESSURE FILTERS
68.111730
60.781543.8
Mounting pattern
120 4.72
11.81300
0.5514
Thru4 Places
592.323.32
71628.18
11.81300
2 placesG 1/2"port
P Clogging indicator
for element removal
port Filling connection
915
2 placesG 3/4"
[36.02]
Clearance required
∆
Connection for staticclogging indicator
G 1/2"2 places
77.8 3.06
Lid top260
10.24
1003.94 13.21
335.5
17.81 452.3
15.96405.5
0.75
19Thru8 places
5.12130Bolt
Spacing OUTLET
4" Flange
4" FlangeSAE DN100
INLETSAE DN100
2 places
OUTLETIsolation valve
INLETIsolation valve
Drainmanifold(Option)
Manual ventvalves Option
G 1/2" ports
Dirty SideDrain PortG 1/2"
25.66652
7.87200
Size 5214
Weight (lbs.) 291
Dimensions shown are [inches] millimeters for general information and overall envelope size only. Weights listed include element. For complete dimensions please contact HYDAC to request a certified print.
Dimensions: NF 5214 2.0 Version (Modular Parallel)
D184 PN#02081318 / 03.16 / FIL1505-1696
LOW PRESSURE FILTERS
Size 7810
Weight (lbs.) 370
Dimensions shown are [inches] millimeters for general information and overall envelope size only. Weights listed include element. For complete dimensions please contact HYDAC to request a certified print.
Dimensions: NF 7810 2.0 Version (Modular Parallel)
1338.3 52.69
60.081526
3 places
∆port
P Clogging indicator
3 places
G 1/2"
G 3/4"port Filling connection
Connection for staticclogging indicator
G 1/2"3 places
405.515.96
SpacingBolt 1305.12
1003.94
77.8 3.06
335.5 13.21
452.3 17.81
0.75
8 places
19Thru
10.24260
Lid Top
[36.02]915Clearance requiredfor element removal
Mounting pattern
34813.7
14
thru6 places
0.55
11.81 300
4.72120
300 11.81
592.3 23.32
11.81 300
42.671084
INLETIsolation valve
INLET
SAE DN1004" Flange
OUTLET
Isolation valveOUTLET
Drainmanifold(Option)
4" FlangeSAE DN100
Manual ventvalves Option(G 1/2" ports)(3 places)
Dirty Side Drain PortG 1/2"
869.734.24
7.87200
D185PN#02081318 / 03.16 / FIL1505-1696
LOW PRESSURE FILTERS
Size 7814
Weight (lbs.) 380
Dimensions shown are [inches] millimeters for general information and overall envelope size only. Weights listed include element. For complete dimensions please contact HYDAC to request a certified print.
1338.3 52.69
60.081526
3 places
∆port
P Clogging indicator
3 places
G 1/2"
G 3/4"port Filling connection
Connection for staticclogging indicator
G 1/2"3 places
405.515.96
SpacingBolt 1305.12
1003.94
77.8 3.06
335.5 13.21
452.3 17.81
0.75
8 places
19Thru
10.24260
Lid Top
[36.02]915Clearance requiredfor element removal
Mounting pattern
34813.7
14
thru6 places
0.55
11.81 300
4.72120
300 11.81
592.3 23.32
11.81 300
42.671084
INLETIsolation valve
INLET
SAE DN1004" Flange
OUTLET
Isolation valveOUTLET
Drainmanifold(Option)
4" FlangeSAE DN100
Manual ventvalves Option(G 1/2" ports)(3 places)
Dirty Side Drain PortG 1/2"
869.734.24
7.87200
Dimensions: NF 7814 2.0 Version (Modular Parallel)
D186 PN#02081318 / 03.16 / FIL1505-1696
LOW PRESSURE FILTERS
Size 10410
Weight (lbs.) 554
Dimensions shown are [inches] millimeters for general information and overall envelope size only. Weights listed include element. For complete dimensions please contact HYDAC to request a certified print.
Dimensions: NF 10410 2.0 Version (Modular Parallel)
60.081526
INLETIsolation valve
SAE DN100INLET
SAE DN100
(Option)manifoldDrain
OUTLET
4" Flange
Isolation valve
OUTLET
4" Flange
Manual ventvalves Option(G 1/2" ports)(4 places)
Dirty SideDrain PortG1/2"
7.87200
49.28
1251.8
4 places
for element removal
port
[
G 1/2"
G 3/4"
91536.02]
Clearance required
4 places
port P Clogging indicator∆
Filling connection
Connection for staticclogging indicator
G 1/2"4 places
405.515.96
8 places
0.75
77.8
Lid top260
19
3.06
10.24
Thru
3.94100
1338.3
335.5 13.21
17.81 452.3
52.69
5.12130Bolt
Spacing
51.221301
11.81
23.32592.3
30011.81
300
11.81300
Mounting pattern
11.81
300
0.55
Thru14
300
8 Places
300 11.81
11.81
4.72120
D187PN#02081318 / 03.16 / FIL1505-1696
LOW PRESSURE FILTERS
Size 10414
Weight (lbs.) 562
Dimensions shown are [inches] millimeters for general information and overall envelope size only. Weights listed include element. For complete dimensions please contact HYDAC to request a certified print.
Dimensions: NF 10414 2.0 Version (Modular Parallel)
68.111730
60.781543.8
Mounting pattern
11.81
11.81
8 Places
0.55
11.81
300
300
300
Thru
14
4.72120
INLETINLET
Isolation valve
SAE DN100
SAE DN1004" Flange
manifold
Isolation valve
4" Flange
OUTLET
(Option)
OUTLET
Drain
Manual ventvalves OptionG 1/2" ports4 places
Dirty SideDrain PortG 1/2"
7.87200
49.28
1251.8
300
23.32
11.81
300 11.81
51.22
592.3
1301
11.81300
for element removal
G 1/2"
4 places
[36.02]
4 places
915Clearance required
P Clogging indicatorport ∆
port G 3/4"
Filling connection
Connection for staticclogging indicator
G 1/2"4 places
19Thru
0.75
3.06 77.8
5.12130Bolt
Spacing
3.94100
335.513.21
452.3 17.81
405.5
8 places
15.96
10.24260
Lid top
D188 PN#02081318 / 03.16 / FIL1505-1696
LOW PRESSURE FILTERS
Size 5210DC7
Weight (lbs.) 530
Dimensions shown are [inches] millimeters for general information and overall envelope size only. Weights listed include element. For complete dimensions please contact HYDAC to request a certified print.
Dimensions: NF 5210DC7 2.0 Version (Modular Parallel High Flow)
18.94481
60.591539
64.83
1646.7
Mounting Pattern
Manual ventvalves Option (G 1/2" ports)
(2 places)
(2 places)
INLET
300 lb flange
300 lb flange6" ANSI CS
OUTLET6" ANSI CS
∆ P Clogging indicatorport G 1/2"
Drainmanifold(Option)
1315.751.8
761.529.98
25.84656.4
for staticclogging
Isolation valveINLET
2 places
indicator G 1/2"
(G 3/4" )
2 places
Connection
Filling connection
Isolation valveOUTLET
743.429.27
15.39391
M16 X 2ThreadedTyp
38.11.5
4
101.6
345.9
38.1
13.62
1.5
38.11.5
12.12307.8
[36.02]915
Clearance requiredfor element removal
11.81300
D189PN#02081318 / 03.16 / FIL1505-1696
LOW PRESSURE FILTERS
Size 7810DC7
Weight (lbs.) 679
Dimensions shown are [inches] millimeters for general information and overall envelope size only. Weights listed include element. For complete dimensions please contact HYDAC to request a certified print.
Dimensions: NF 7810DC7 2.0 Version (Modular Parallel High Flow)
1487 58.54
64.79
1645.7
18.94481
port G 1/2"
3 places
(3 Places)
Dirty Side ∆
3 Placesindicator
P Clogging
OUTLETIsolation valve
Drain Port
connection
G 1/2"
G 3/4"
INLETIsolation valve
Filling
Connection for staticclogging indicator G 1/2"3 places
10.24
260Lid top
30.05 763.4
41116.18
7.87200
M16 X 2Threaded Typ
25.12
101.6
638.1
30011.81
30011.81
38.11.5
4
1.5
38.1
11.81300 300
11.81
5.9150
[36.02]915
Clearance requiredfor element removal
300 lb flange6" ANSI CSINLET
DrainmanifoldOption
OUTLET6" ANSI CS300 lb flange
51.81315.7
39.76
1009.8
6.25
158.8
Mounting Pattern
valves Option
3 placesG 1/2" ports
Manual vent
∆ P Clogging indicatorport G 1/2"(3 places)
D190 PN#02081318 / 03.16 / FIL1505-1696
LOW PRESSURE FILTERS
All Element K Factors in psi / gpm.
Sizing InformationTotal pressure loss through the filter is as follows:
Assembly ∆P = Housing ∆P + Element ∆P
Housing Curve:
Pressure loss through housing is as follows:
Housing ∆P = Housing Curve ∆P x Actual Specific Gravity
0.86
Adjustments must be made for viscosity & specific gravity of the fluid to be used! (see “Sizing HYDAC Filter Assemblies” in Section B - Overview)
0 100 200 300 400 500
0
0.2
0.4
0.8
0.6
0
2
4
6
10
8
0 20 40 60 80 120 140 100
NF 330/500/750 HOUSINGQ in l/min
Q in gpm
0 400 800 1200 1600 2000
0
0.1
0.2
0.3
0
1.0
2.0
3.0
4.0
0 100 200 300 400 500
NF 1310-2650 HOUSINGQ in l/min
Q in gpm
NF 5210 HOUSINGQ in l/min
Q in gpm
0
0.05
0.1
0.15
0.2 0 400 800 1200 1600 2000
0
1.0
2.0
3.0
0 100 200 300 400 500
NF 7810 HOUSINGQ in l/min
Q in gpm
NF 10410 HOUSINGQ in l/min
Q in gpm
0
0.04
0.08
0.12
0.16
0 400 800 1200 1600 2000
0
0.5
1.0
1.5
2.0
2.5
0 100 200 300 400 5000
0.04
0.08
0.12
0 400 800 1200 1600 2000
0
0.4
0.8
1.2
1.6
2.0
0 100 200 300 400 500
NF 5210DC7 HOUSINGQ in l/min
Q in gpm
NF 7810DC7 HOUSINGQ in l/min
Q in gpm0
0
5.0
10.0
15.0
20.0
25.0
0
0.3
0.9
0.6
1.2
1.5
1.8
250 500 750 1000 1250 1500
0 1000 2000 3000 4000 60005000
00
5.0
10.0
0
0.3
0.6
0.9
250 500 750 1000 1250 1500
0 1000 2000 3000 4000 5000 6000
D191PN#02081318 / 03.16 / FIL1505-1696
LOW PRESSURE FILTERSElement K Factors
∆P Elements = Elements (K) Flow Factor x Flow Rate (gpm) x Actual Viscosity (SUS) x Actual Specific Gravity
(From Tables Below) 141 SUS 0.86
Optimicron …R…ON Size 1 µm 3 µm 5 µm 10 µm 15 µm 20 µm
1300 R XXX ON 0.094 0.04 0.032 0.019 0.018 0.0122600 R XXX ON 0.046 0.02 0.016 0.01 0.009 0.006
ECOmicron ...R...ECON2Size 3 μm 5 μm 10 μm 20 μm
1300 R XXX ECON2 0.044 0.033 0.022 0.0162600 R XXX ECON2 0.022 0.016 0.011 0.005
ECOmicron fit 1.14.XXDXXECO/NSize 3 μm 6 μm 12 μm 25 μm
1.14.16DXXECO/N 0.046 0.041 0.022 0.0151.14.39DXXECO/N 0.017 0.016 0.008 0.006
Notes