lm-79 distribution testing: total luminous flux, 3.5 3029 3009 2995 2986 2997 3005 3044 ... 2936...

9
LM-79 Distribution Test Report (Luminaire) Total Luminous Flux, Luminous Intensity Distribution and Electrical Characteristics of Customer Submitted Luminaire Report No.: PHM-RPT-171026-D07 Date: October 26, 2017 Page 1 of 9 LM-79 Distribution Testing: Total Luminous Flux, Luminous Intensity Distribution, Electrical Characteristics and Efficacy. Report Prepared for: Vantage Lighting 181 Narragansett Park Drive East Providence, RI 02916 USA Telephone: (860) 564-4512 Description : 2” Recessed Downlight Model Tested: V2CRRU-1335K-N WO/CS#: R3243 Report Issue Date: October 26, 2017 Date of Test(s): October 24-26, 2017 Total Number of Pages : 9 (including this page) Report Reviewed by: Mark Razvi Photometric Lab Supervisor Curtis-Straus

Upload: ngophuc

Post on 22-Feb-2018

221 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: LM-79 Distribution Testing: Total Luminous Flux, 3.5 3029 3009 2995 2986 2997 3005 3044 ... 2936 2954 2992 3007 3.8 3012 2991 2975 2971 2991 2990 3024 3031 ... 4 2995 2972 2968 2966

LM-79 Distribution Test Report (Luminaire)

Total Luminous Flux, Luminous Intensity Distribution and Electrical Characteristics of Customer Submitted Luminaire

Report No.: PHM-RPT-171026-D07 Date: October 26, 2017

Page 1 of 9

LM-79 Distribution Testing: Total Luminous Flux, Luminous Intensity Distribution, Electrical

Characteristics and Efficacy.

Report Prepared for:

Vantage Lighting 181 Narragansett Park Drive East Providence, RI 02916

USA Telephone: (860) 564-4512

Description : 2” Recessed Downlight

Model Tested: V2CRRU-1335K-N WO/CS#: R3243

Report Issue Date: October 26, 2017 Date of Test(s): October 24-26, 2017 Total Number of Pages : 9 (including this page)

Report Reviewed by:

Mark Razvi

Photometric Lab Supervisor Curtis-Straus

Page 2: LM-79 Distribution Testing: Total Luminous Flux, 3.5 3029 3009 2995 2986 2997 3005 3044 ... 2936 2954 2992 3007 3.8 3012 2991 2975 2971 2991 2990 3024 3031 ... 4 2995 2972 2968 2966

LM-79 Distribution Test Report (Luminaire)

Total Luminous Flux, Luminous Intensity Distribution and Electrical Characteristics of Customer Submitted Luminaire

Report No.: PHM-RPT-171026-D07 Date: October 26, 2017

Page 2 of 9

DETAILED PRODUCT DESCRIPTION Model # V2CRRU-1335K-N CS/WO# R3243 Description 2” Recessed Downlight Supply Voltage 120VAC Pictures:

Page 3: LM-79 Distribution Testing: Total Luminous Flux, 3.5 3029 3009 2995 2986 2997 3005 3044 ... 2936 2954 2992 3007 3.8 3012 2991 2975 2971 2991 2990 3024 3031 ... 4 2995 2972 2968 2966

LM-79 Distribution Test Report (Luminaire)

Total Luminous Flux, Luminous Intensity Distribution and Electrical Characteristics of Customer Submitted Luminaire

Report No.: PHM-RPT-171026-D07 Date: October 26, 2017

Page 3 of 9

Curtis-Straus Photometric Testing Information

Photometric Testing is performed in accordance with the procedures outlined in LM-79-2008 . The test sample is evaluated for photometric and electrical characteristics using the equipment listed below.

Curtis-Straus Environmental Testing Info Curtis-Straus testing laboratory temperature during testing: 25.0 °C .

LIST OF EQUIPMENT USED: Description Model

No. Serial No. Asset

No Cal. Date

Cal. Due

Yokogawa Power Meter

WT-310E C2SK21021V

2356 12-19-16` 12-19-17

Chroma AC Power Supply

61603 616030001283 2355 04-21-17 04-21-18

LabSphere Type-C GoniometerSystem

PM-150-140 022172153 AA-30058-195

10-17-17 11-17-17

Digital Thermometer

4627 160739886 2392 09-07-16 09-07-18

This technical report may only be quoted in full. Any use for advertising purposes must be granted in writing. This report is the result of a single examination of the object in question and is not generally applicable evaluation of the quality of other products in regular production.

Page 4: LM-79 Distribution Testing: Total Luminous Flux, 3.5 3029 3009 2995 2986 2997 3005 3044 ... 2936 2954 2992 3007 3.8 3012 2991 2975 2971 2991 2990 3024 3031 ... 4 2995 2972 2968 2966

LM-79 Distribution Test Report (Luminaire)

Total Luminous Flux, Luminous Intensity Distribution and Electrical Characteristics of Customer Submitted Luminaire

Report No.: PHM-RPT-171026-D07 Date: October 26, 2017

Page 4 of 9

LM-79-2008 Distribution Test Data

Model # V2CRRU-1335K-N CS/WO# R3243 Description 2” Recessed Downlight Supply Voltage 120VAC

Result of Tests

Photometric and Electrical Test Data

Input Voltage: 120 VAC

Base Orientation: Base Up

Lumens (lm) Watts (W) Volts (VAC) Amps (A) Efficacy PF Ithd (%)

1138.94 14.67 120.20 0.12 77.63 0.9910 0.12

Luminous Intensity Summary: Cd Illumination Cone of Light Mounting Ht: 10 ft.

Page 5: LM-79 Distribution Testing: Total Luminous Flux, 3.5 3029 3009 2995 2986 2997 3005 3044 ... 2936 2954 2992 3007 3.8 3012 2991 2975 2971 2991 2990 3024 3031 ... 4 2995 2972 2968 2966

LM-79 Distribution Test Report (Luminaire)

Total Luminous Flux, Luminous Intensity Distribution and Electrical Characteristics of Customer Submitted Luminaire

Report No.: PHM-RPT-171026-D07 Date: October 26, 2017

Page 5 of 9

IsoCandela Plot

Zonal Lumens Summary Lumens per Zone

Page 6: LM-79 Distribution Testing: Total Luminous Flux, 3.5 3029 3009 2995 2986 2997 3005 3044 ... 2936 2954 2992 3007 3.8 3012 2991 2975 2971 2991 2990 3024 3031 ... 4 2995 2972 2968 2966

LM-79 Distribution Test Report (Luminaire)

Total Luminous Flux, Luminous Intensity Distribution and Electrical Characteristics of Customer Submitted Luminaire

Report No.: PHM-RPT-171026-D07 Date: October 26, 2017

Page 6 of 9

Candela Table - Type C

0 22.5 45 67.5 90 112.5 135 157.5 180 202.5 225 247.5 270 292.5 315 337.5 360

0 3094 3094 3094 3094 3094 3094 3094 3094 3094 3094 3094 3094 3094 3094 3094 3094 3094

0.1 3105 3090 3092 3091 3085 3097 3129 3138 3163 3119 3087 3065 3035 3029 3047 3109 3119

0.2 3104 3092 3096 3091 3081 3099 3133 3142 3161 3119 3086 3065 3031 3028 3051 3108 3115

0.3 3103 3092 3096 3089 3077 3100 3136 3144 3159 3118 3082 3061 3027 3029 3055 3107 3111

0.4 3105 3093 3097 3086 3073 3101 3138 3147 3154 3119 3079 3057 3027 3032 3057 3103 3107

0.5 3108 3093 3096 3082 3073 3097 3137 3146 3149 3121 3075 3053 3026 3035 3057 3098 3103

0.6 3111 3095 3092 3077 3072 3093 3133 3144 3145 3123 3071 3050 3026 3037 3058 3095 3100

0.7 3113 3096 3087 3072 3072 3089 3130 3141 3142 3124 3068 3048 3029 3039 3053 3092 3100

0.8 3115 3096 3083 3070 3074 3085 3125 3136 3139 3125 3066 3047 3032 3041 3049 3089 3101

0.9 3115 3094 3078 3069 3076 3082 3119 3130 3139 3126 3065 3048 3034 3038 3045 3089 3102

1 3112 3093 3073 3068 3077 3080 3115 3126 3142 3122 3065 3049 3034 3034 3040 3090 3105

1.1 3108 3088 3072 3072 3078 3080 3114 3123 3144 3118 3067 3051 3035 3030 3036 3091 3107

1.2 3104 3082 3072 3075 3079 3080 3113 3121 3145 3114 3069 3053 3032 3025 3034 3092 3107

1.3 3099 3076 3072 3077 3077 3081 3113 3121 3146 3109 3071 3056 3028 3019 3034 3092 3106

1.4 3094 3072 3074 3077 3073 3083 3115 3122 3146 3104 3071 3054 3023 3015 3034 3093 3105

1.5 3090 3068 3076 3076 3069 3085 3117 3123 3142 3100 3071 3053 3018 3013 3035 3091 3101

1.6 3087 3065 3077 3073 3064 3083 3118 3124 3138 3098 3070 3050 3013 3010 3036 3089 3097

1.7 3084 3065 3075 3068 3058 3081 3117 3125 3132 3096 3065 3045 3009 3010 3038 3085 3093

1.8 3084 3066 3073 3062 3053 3078 3117 3126 3125 3097 3061 3039 3006 3012 3036 3080 3087

1.9 3084 3066 3069 3056 3051 3072 3111 3122 3118 3098 3055 3034 3004 3013 3033 3074 3081

2 3084 3067 3062 3049 3049 3066 3106 3117 3113 3099 3049 3029 3002 3011 3030 3068 3076

2.1 3084 3067 3055 3042 3048 3060 3100 3112 3110 3097 3043 3025 3003 3009 3023 3063 3073

2.2 3085 3064 3050 3039 3048 3055 3094 3105 3107 3095 3039 3023 3004 3007 3016 3058 3069

2.3 3082 3061 3044 3037 3049 3049 3088 3098 3107 3092 3037 3023 3004 3001 3010 3056 3067

2.4 3077 3057 3039 3035 3048 3047 3083 3092 3108 3087 3035 3023 3004 2995 3005 3056 3066

2.5 3072 3049 3036 3035 3047 3046 3082 3088 3108 3082 3035 3023 3004 2989 3000 3055 3065

2.6 3064 3042 3035 3034 3045 3045 3080 3084 3106 3076 3036 3023 2998 2982 2997 3055 3065

2.7 3056 3035 3033 3032 3039 3045 3079 3083 3105 3068 3036 3023 2991 2975 2996 3055 3064

2.8 3048 3029 3032 3029 3032 3045 3080 3083 3102 3060 3033 3017 2984 2970 2995 3053 3063

2.9 3043 3024 3031 3026 3024 3044 3080 3083 3095 3054 3031 3011 2975 2966 2995 3048 3056

3 3038 3020 3029 3020 3016 3039 3076 3081 3088 3049 3026 3005 2966 2961 2995 3043 3050

3.1 3035 3017 3025 3014 3008 3035 3072 3079 3080 3044 3018 2997 2959 2960 2994 3036 3042

3.2 3034 3014 3020 3007 3002 3028 3067 3076 3072 3043 3011 2988 2956 2960 2990 3027 3033

3.3 3033 3012 3013 3000 3000 3020 3060 3069 3064 3042 3003 2982 2952 2958 2985 3019 3025

3.4 3032 3011 3004 2993 2998 3012 3052 3061 3060 3040 2995 2977 2950 2955 2979 3011 3018

3.5 3029 3009 2995 2986 2997 3005 3044 3054 3056 3037 2987 2972 2949 2951 2970 3004 3013

3.6 3026 3004 2988 2980 2996 2999 3036 3045 3053 3034 2981 2969 2948 2945 2962 2997 3008

Page 7: LM-79 Distribution Testing: Total Luminous Flux, 3.5 3029 3009 2995 2986 2997 3005 3044 ... 2936 2954 2992 3007 3.8 3012 2991 2975 2971 2991 2990 3024 3031 ... 4 2995 2972 2968 2966

LM-79 Distribution Test Report (Luminaire)

Total Luminous Flux, Luminous Intensity Distribution and Electrical Characteristics of Customer Submitted Luminaire

Report No.: PHM-RPT-171026-D07 Date: October 26, 2017

Page 7 of 9

3.7 3019 2998 2981 2975 2995 2993 3029 3037 3052 3029 2976 2967 2945 2936 2954 2992 3007

3.8 3012 2991 2975 2971 2991 2990 3024 3031 3050 3021 2971 2965 2941 2928 2946 2988 3005

3.9 3004 2982 2971 2968 2985 2987 3021 3026 3048 3014 2970 2962 2938 2919 2938 2984 3003

4 2995 2972 2968 2966 2980 2985 3018 3021 3041 3005 2969 2959 2929 2910 2934 2980 2999

4.1 2985 2964 2965 2962 2970 2982 3016 3019 3034 2996 2967 2955 2921 2901 2931 2977 2995

4.2 2976 2957 2963 2958 2960 2980 3013 3018 3026 2987 2963 2947 2912 2896 2928 2973 2989

4.3 2970 2950 2960 2954 2950 2975 3010 3015 3015 2981 2959 2939 2902 2891 2925 2967 2980

4.4 2963 2946 2955 2945 2940 2966 3003 3010 3005 2975 2952 2930 2892 2887 2921 2962 2971

4.5 2958 2942 2948 2936 2931 2957 2997 3005 2996 2970 2943 2920 2885 2884 2916 2953 2961

4.6 2955 2938 2940 2927 2924 2948 2989 2997 2988 2966 2935 2910 2878 2882 2908 2943 2952

4.7 2952 2934 2930 2916 2919 2938 2980 2986 2981 2962 2924 2901 2872 2878 2900 2932 2942

4.8 2947 2930 2920 2905 2914 2928 2971 2976 2977 2958 2914 2893 2868 2871 2890 2922 2936

4.9 2942 2925 2909 2896 2910 2921 2962 2965 2973 2952 2904 2885 2864 2864 2880 2912 2930

5 2936 2917 2900 2888 2905 2914 2953 2955 2969 2946 2897 2881 2860 2855 2869 2903 2925

5.1 2926 2908 2891 2880 2901 2908 2944 2945 2964 2937 2890 2876 2854 2843 2860 2897 2921

5.2 2916 2899 2883 2875 2894 2903 2937 2939 2959 2926 2884 2872 2849 2831 2851 2890 2917

5.3 2905 2887 2877 2871 2886 2899 2931 2934 2951 2915 2880 2866 2842 2822 2843 2884 2911

5.4 2893 2876 2872 2866 2878 2894 2926 2929 2940 2903 2875 2861 2832 2813 2837 2880 2904

5.5 2882 2866 2866 2861 2867 2888 2920 2925 2928 2891 2869 2853 2821 2804 2832 2875 2896

5.6 2872 2857 2861 2855 2855 2882 2915 2920 2917 2880 2862 2842 2810 2798 2827 2867 2886

5.7 2864 2848 2856 2848 2844 2873 2909 2915 2906 2874 2854 2831 2799 2792 2821 2859 2872

5.8 2856 2842 2848 2836 2833 2863 2901 2905 2895 2867 2843 2819 2788 2786 2815 2851 2859

5.9 2850 2837 2838 2824 2823 2852 2892 2896 2886 2861 2830 2806 2779 2780 2807 2839 2848

6 2844 2832 2828 2812 2814 2840 2881 2885 2878 2854 2818 2794 2770 2775 2796 2828 2837

6.1 2839 2825 2815 2799 2807 2828 2868 2873 2870 2848 2806 2785 2761 2767 2786 2816 2827

6.2 2831 2818 2802 2786 2799 2816 2855 2860 2864 2839 2794 2776 2755 2758 2774 2804 2820

6.3 2822 2809 2789 2777 2793 2805 2843 2849 2858 2829 2784 2768 2750 2749 2761 2791 2813

6.4 2813 2796 2779 2769 2786 2794 2832 2837 2851 2819 2777 2762 2743 2736 2749 2780 2806

6.5 2799 2783 2769 2762 2779 2784 2821 2826 2840 2806 2770 2755 2733 2723 2739 2770 2799

6.6 2786 2770 2759 2755 2768 2777 2814 2817 2830 2792 2763 2748 2724 2709 2729 2760 2792

6.7 2772 2758 2752 2748 2758 2770 2806 2809 2818 2778 2756 2739 2713 2698 2720 2753 2782

6.8 2760 2745 2744 2740 2746 2763 2799 2801 2803 2766 2749 2729 2700 2687 2714 2745 2769

6.9 2748 2735 2737 2731 2732 2754 2791 2793 2788 2754 2739 2718 2687 2677 2708 2738 2757

7 2737 2726 2729 2721 2718 2746 2784 2786 2775 2744 2729 2705 2674 2669 2701 2728 2743

7.1 2727 2717 2721 2709 2706 2735 2774 2776 2762 2736 2718 2691 2660 2661 2692 2718 2728

7.2 2717 2710 2710 2695 2694 2723 2761 2764 2749 2729 2704 2678 2647 2654 2683 2706 2713

7.3 2709 2703 2699 2681 2681 2711 2748 2751 2741 2720 2689 2664 2638 2646 2672 2693 2703

7.4 2702 2696 2687 2667 2673 2696 2733 2737 2733 2711 2675 2650 2629 2638 2659 2679 2693

7.5 2694 2685 2672 2655 2664 2680 2718 2722 2725 2702 2662 2642 2621 2627 2647 2665 2684

7.6 2683 2675 2658 2642 2656 2666 2703 2707 2715 2688 2649 2633 2614 2614 2631 2651 2677

Page 8: LM-79 Distribution Testing: Total Luminous Flux, 3.5 3029 3009 2995 2986 2997 3005 3044 ... 2936 2954 2992 3007 3.8 3012 2991 2975 2971 2991 2990 3024 3031 ... 4 2995 2972 2968 2966

LM-79 Distribution Test Report (Luminaire)

Total Luminous Flux, Luminous Intensity Distribution and Electrical Characteristics of Customer Submitted Luminaire

Report No.: PHM-RPT-171026-D07 Date: October 26, 2017

Page 8 of 9

7.7 2673 2663 2644 2633 2647 2654 2691 2694 2705 2673 2637 2624 2606 2601 2616 2637 2670

7.8 2661 2648 2632 2624 2639 2643 2679 2682 2693 2657 2629 2615 2597 2586 2602 2625 2661

7.9 2645 2632 2620 2616 2628 2633 2668 2671 2679 2642 2620 2606 2585 2572 2592 2615 2650

8 2630 2618 2610 2605 2613 2625 2660 2662 2664 2626 2610 2594 2572 2558 2581 2604 2639

8.1 2615 2605 2602 2595 2599 2617 2652 2653 2648 2611 2598 2579 2558 2548 2572 2596 2625

8.2 2601 2592 2593 2583 2584 2607 2642 2644 2632 2601 2587 2563 2543 2538 2563 2587 2608

8.3 2587 2583 2581 2566 2569 2595 2630 2632 2616 2591 2572 2548 2528 2529 2554 2577 2591

8.4 2576 2574 2569 2549 2554 2583 2618 2621 2606 2580 2556 2533 2517 2520 2542 2564 2578

8.5 2566 2566 2557 2534 2543 2567 2603 2607 2597 2569 2541 2518 2506 2512 2527 2550 2565

8.6 2555 2554 2540 2522 2534 2551 2586 2589 2588 2559 2526 2508 2496 2501 2512 2535 2552

8.7 2545 2542 2523 2510 2524 2535 2569 2572 2576 2545 2511 2499 2487 2487 2497 2519 2543

8.8 2536 2529 2508 2500 2514 2522 2554 2557 2565 2529 2498 2490 2478 2474 2481 2503 2534

8.9 2524 2512 2496 2491 2504 2509 2540 2543 2552 2513 2489 2480 2468 2458 2465 2489 2524

9 2509 2494 2483 2483 2492 2497 2527 2529 2534 2497 2479 2470 2455 2442 2455 2477 2510

9.1 2494 2479 2472 2470 2476 2487 2517 2518 2517 2482 2468 2458 2442 2427 2445 2464 2497

9.2 2478 2467 2463 2456 2460 2478 2508 2508 2501 2467 2457 2443 2429 2416 2434 2453 2482

9.3 2461 2455 2453 2442 2444 2466 2497 2496 2486 2456 2445 2427 2415 2405 2423 2443 2465

9.4 2444 2444 2440 2425 2428 2453 2483 2483 2470 2446 2430 2412 2401 2394 2411 2432 2448

9.5 2431 2434 2425 2408 2413 2440 2469 2469 2459 2435 2413 2398 2389 2384 2397 2417 2433

9.6 2419 2424 2410 2392 2401 2423 2452 2454 2449 2423 2396 2384 2379 2374 2380 2402 2420

9.7 2407 2410 2394 2380 2390 2406 2434 2436 2438 2411 2382 2373 2369 2361 2363 2386 2406

9.8 2396 2394 2378 2368 2380 2388 2415 2418 2424 2398 2367 2363 2358 2347 2348 2369 2395

9.9 2385 2378 2362 2357 2368 2375 2400 2403 2409 2381 2353 2353 2345 2332 2332 2352 2384

10 2373 2361 2349 2346 2355 2361 2388 2389 2394 2364 2343 2341 2332 2317 2317 2337 2373

15 1637 1637 1633 1635 1637 1638 1647 1645 1642 1644 1650 1649 1638 1621 1618 1614 1639

20 1027 1030 1024 1033 1036 1043 1043 1039 1030 1034 1036 1042 1056 1050 1048 1039 1030

25 624 617 612 621 620 622 619 618 610 603 600 607 628 639 637 632 623

30 329 328 326 328 324 323 318 312 307 308 310 317 321 328 334 332 328

35 97 102 105 107 106 97 89 84 80 79 82 85 85 89 90 91 97

40 35 36 37 36 35 34 33 33 32 31 32 32 32 32 32 33 35

45 20 21 21 20 20 19 19 19 19 19 19 19 18 19 18 19 20

50 11 11 11 11 11 11 11 10 10 10 11 11 11 11 10 11 11

55 8 8 8 8 9 8 8 8 8 8 8 9 9 8 8 8 8

60 6 7 7 7 7 7 7 7 7 6 6 7 7 6 6 6 6

65 5 5 5 6 6 6 5 5 5 5 5 5 5 5 5 5 5

70 5 5 5 6 5 5 5 5 5 5 5 5 4 5 5 5 5

75 5 5 5 6 5 5 5 5 5 5 5 4 4 4 5 5 5

80 5 5 5 5 5 5 5 5 5 4 4 4 4 4 4 4 4

85 5 5 5 5 5 5 5 5 4 4 4 4 4 4 4 4 4

90 3 3 4 4 4 4 3 3 3 3 3 3 3 3 3 3 3

Page 9: LM-79 Distribution Testing: Total Luminous Flux, 3.5 3029 3009 2995 2986 2997 3005 3044 ... 2936 2954 2992 3007 3.8 3012 2991 2975 2971 2991 2990 3024 3031 ... 4 2995 2972 2968 2966

LM-79 Distribution Test Report (Luminaire)

Total Luminous Flux, Luminous Intensity Distribution and Electrical Characteristics of Customer Submitted Luminaire

Report No.: PHM-RPT-171026-D07 Date: October 26, 2017

Page 9 of 9

95 3 3 3 4 3 3 3 3 3 3 3 3 3 3 3 3 3

100 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3

105 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3

110 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3

115 3 4 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3

120 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3

125 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3

130 3 3 4 3 3 3 3 3 3 3 3 3 3 3 4 3 3

135 4 4 4 3 4 4 3 3 3 3 3 3 3 3 3 3 3

140 4 4 4 4 4 4 4 4 3 3 3 3 3 3 4 4 4

145 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4

150 4 4 5 5 5 5 5 4 4 4 4 4 4 4 4 4 4

155 5 5 5 5 5 5 5 5 5 4 5 4 4 4 4 4 5

160 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5

165 5 5 5 5 5 5 6 5 5 5 5 5 5 5 5 5 5

170 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5

175 5 5 6 6 6 6 6 5 5 5 5 5 5 5 5 5 5

180 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5