lm-79-08 test report for · spectral standard osi 9005- sb #04-05 09/01/2008 (5) a.c. power supply...

12
Page 1 of 12 LM79201306133 LM-79-08 Test Report for OSRAM SYLVANIA INC. 100 Endicott Street Danvers, MA 01923 Model(s): Sylvania LED10A19/F/827/RP (Sample 28) 13 June 2013 This test report presents the results of measurements performed on the product Sylvania LED10A19/F/827/RP (Sample 28) in accordance with LM-79-08 Electrical and Photometric Measurements of Solid-State Lighting Products. Test Personnel: J. Evans D. Dionne Test Date: 6/13/2013 (Goniophotometry) 6/13/2013 (Integrating Sphere) NVLAP Signatory: 6/14/2013 X Mark B. Sapcoe Principal Engineer Mark B. Sapcoe Laboratory: Analytics & Metrology NVLAP Code: 100403-0 OSRAM SYLVANIA INC. 71 Cherry Hill Drive Beverly, MA 01915 Voice: 978-750-1620 Fax: 978-750-1799 [email protected] Report Number: LM79201306133 Associated Request Number(s): 20134396 FOR THE SCOPE OF ACCREDITATION UNDER NVLAP LAB CODE 100403-0 This report does not imply product certification, approval or endorsement by NVLAP, NIST or any agency of the federal government.

Upload: others

Post on 20-Jul-2020

1 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: LM-79-08 Test Report for · Spectral Standard OSI 9005- SB #04-05 09/01/2008 (5) A.C. Power Supply Kikusui PCR500M MD003520 Not required A.C. Line Conditioner Elgar 5000B 4924 Not

Page 1 of 12 LM79201306133

LM-79-08 Test Report for

OSRAM SYLVANIA INC. 100 Endicott Street Danvers, MA 01923

Model(s): Sylvania LED10A19/F/827/RP (Sample 28) 13 June 2013 This test report presents the results of measurements performed on the product Sylvania LED10A19/F/827/RP (Sample 28) in accordance with LM-79-08 Electrical and Photometric Measurements of Solid-State Lighting Products.

Test Personnel: J. Evans D. Dionne

Test Date: 6/13/2013 (Goniophotometry) 6/13/2013 (Integrating Sphere)

NVLAP Signatory:

6/14/2013

XMark B. Sapcoe

Principal Engineer Mark B. Sapcoe

Laboratory: Analytics & Metrology NVLAP Code: 100403-0

OSRAM SYLVANIA INC.

71 Cherry Hill Drive Beverly, MA 01915 Voice: 978-750-1620 Fax: 978-750-1799

[email protected]

Report Number: LM79201306133

Associated Request Number(s): 20134396

FOR THE SCOPE OF ACCREDITATION UNDER NVLAP LAB CODE 100403-0

This report does not imply product certification, approval or endorsement by NVLAP, NIST or any agency of the federal government.

Page 2: LM-79-08 Test Report for · Spectral Standard OSI 9005- SB #04-05 09/01/2008 (5) A.C. Power Supply Kikusui PCR500M MD003520 Not required A.C. Line Conditioner Elgar 5000B 4924 Not

Page 2 of 12 LM79201306133

General Information Product tested Sylvania LED10A19/F/827/RP (Sample 28)

Purpose of test This test report is prepared on behalf of OSRAM SYLVANIA INC. in accordance with American National Standards Institute standards, Illumination Engineering Society of North America Lighting Methods and International Commission on Illumination (CIE) publications listed below:

IESNA LM-79-08, Approved Method for the Electrical and Photometric Testing of Solid-State Lighting Products

IESNA LM-28-1989, Guide for the Selection, Care and Use of Electrical Instruments in the Photometric Laboratory

CIE Publication No. 13.3-1995, Method of Measuring and Specifying the Color Rendering of Light Sources. The objective is to demonstrate compliance of the product evaluated to LM-79-08 Electrical and Photometric Measurements of Solid-State Lighting Products.

Laboratory Accreditation

Analytics & Metrology (ANM) is a component of OSRAM SYLVANIA, Corporate Technology, Technical Services & Support. ANM is located at 71 Cherry Hill Drive, Beverly, MA 01915.

ANM is accredited under the National Voluntary Laboratory Accreditation Program (NVLAP), Energy Efficient Lighting (EEL) program. NVLAP is a division of the National Institute of Standards and Technology. ANM NVLAP Laboratory Code is 100403-0.

Page 3: LM-79-08 Test Report for · Spectral Standard OSI 9005- SB #04-05 09/01/2008 (5) A.C. Power Supply Kikusui PCR500M MD003520 Not required A.C. Line Conditioner Elgar 5000B 4924 Not

Page 3 of 12 LM79201306133

Test Equipment

Goniometry Equipment Manufacturer Model No. Serial No. Calibration (Cycle in years)

Power Supply Kikusui PCR2000L GM003046 Not required Power Meter Yokogawa WT2030 12V729819 05/6/13 (1) Multimeter/Data Acquisition System Keithley 2700 0780651 05/18/13 (3) 10’ Polar Goniometer OS None None 02/14/13 (1)

Integrating sphere radiometry Equipment Manufacturer Model No. Serial No. Calibration (Cycle in years)

Integrating Sphere 1.5 Meter Dia. B Not required Spectrometer Instrument Systems CAS 140 CT 4414205 06/08/2012 (1) Self Absorption Meter Keithley 2000 1072300 05/17/2013 (3) Lumen Standards OSI 9005 11-12, 10-07 06/08/2012 (1) Spectral Standard OSI 9005- SB #04-05 09/01/2008 (5) A.C. Power Supply Kikusui PCR500M MD003520 Not required A.C. Line Conditioner Elgar 5000B 4924 Not required Power Meter Yokogawa WT2030 12C713520 05/17/2013 (1) D.C. Power Supply Hewlett Packard 6030A 3544A-04230 Not required VDC Meter Keithley 2000 0662960 05/17/2013 (3) ADC Meter Keithley 2000 0620603 05/17/2013 (3) Current Shunt Guildline 9230/15 62485 05/08/2013 (1) Calibration intervals are based on critical evaluations of equipment and standards behavior as per ANS/ISO/IEC 17025:2005(E) 5.10.4.4 All calibrations are directly traceable to a NMI (NIST) through an unbroken chain of calibrations or comparisons.

Page 4: LM-79-08 Test Report for · Spectral Standard OSI 9005- SB #04-05 09/01/2008 (5) A.C. Power Supply Kikusui PCR500M MD003520 Not required A.C. Line Conditioner Elgar 5000B 4924 Not

Page 4 of 12 LM79201306133

Procedure

Goniometry The lamp was operated base up. The lamp reference plane was located at the center of the lamp goniometer at a test distance of 10 feet from the detectors. The lamp was operated at an input voltage of 120VAC supplied by a four contact connection. The lamp was stabilized per the criteria of LM-79 prior to the measurement. Nine (9) vertical scans were taken due to symmetry of the source output. Color uniformity was measured at two

horizontal angles, 0 and 90. Total operating time prior to measurement is approximately 1 hour. Ambient temperature during testing was

maintained at 25C ± 1C.

Integrating Sphere Radiometry Calibration of the sphere-spectroradiometer system was performed using the flux calibration lamp. The lamp was mounted in the sphere base up. The lamp was operated at 120VAC. The lamp was stabilized per the criteria of LM-79 prior to the measurement. After the lamp was stabilized inside the sphere, electrical and spectrophotometric measurements were simultaneously performed.

Ambient temperature during testing was maintained at 25C ± 1C.

Page 5: LM-79-08 Test Report for · Spectral Standard OSI 9005- SB #04-05 09/01/2008 (5) A.C. Power Supply Kikusui PCR500M MD003520 Not required A.C. Line Conditioner Elgar 5000B 4924 Not

Page 5 of 12 LM79201306133

Sylvania LED10A19/F/827/RP (Sample 28)

Measured and Derived Performance Parameters

Voltage /V 120.06Current /A 0.1009

Wattage /W 10.14 R1 80Power Factor 0.8370 R2 89

ITHD 49.72% R3 96Lumens 903 R4 80

Efficacy /LPW 89.0 R5 79x 0.454 R6 85y 0.410 R7 84u’ 0.259 R8 62v’ 0.526 R9 14

Duv 0.0003 R10 74CCT /K 2776 R11 77

CRI 82 R12 70R9 14 R13 81S/P 1.21 R14 98

Tamb /°C 24.5

Integrating Sphere Values

Integrating Sphere Values Special

Color

Rendering

Voltage /V 120.03Current /A 0.0998

Wattage /W 10.16Power Factor 0.8486

ITHD 49.25%Lumens 905

Efficacy /LPW 89.1Tamb /C 24.6

Goniophotometer Values

Goniometric Values

Page 6: LM-79-08 Test Report for · Spectral Standard OSI 9005- SB #04-05 09/01/2008 (5) A.C. Power Supply Kikusui PCR500M MD003520 Not required A.C. Line Conditioner Elgar 5000B 4924 Not

Page 6 of 12 LM79201306133

Sylvania LED10A19/F/827/RP (Sample 28) Absolute Spectral Radiant Flux

0.00E+00

2.00E-03

4.00E-03

6.00E-03

8.00E-03

1.00E-02

1.20E-02

1.40E-02

1.60E-02

1.80E-02

2.00E-02

380 430 480 530 580 630 680 730 780

W/nm

nm

Page 7: LM-79-08 Test Report for · Spectral Standard OSI 9005- SB #04-05 09/01/2008 (5) A.C. Power Supply Kikusui PCR500M MD003520 Not required A.C. Line Conditioner Elgar 5000B 4924 Not

Page 7 of 12 LM79201306133

Sylvania LED10A19/F/827/RP (Sample 28) Absolute Spectral Radiant Flux

nm W/nm nm W/nm nm W/nm nm W/nm nm W/nm380 3.338E-05 464 3.289E-03 548 1.113E-02 632 1.641E-02 716 2.822E-03

382 3.368E-05 466 3.056E-03 550 1.143E-02 634 1.607E-02 718 2.669E-03

384 3.252E-05 468 2.851E-03 552 1.174E-02 636 1.573E-02 720 2.523E-03

386 3.270E-05 470 2.684E-03 554 1.206E-02 638 1.538E-02 722 2.386E-03

388 3.284E-05 472 2.558E-03 556 1.238E-02 640 1.502E-02 724 2.252E-03

390 3.334E-05 474 2.489E-03 558 1.269E-02 642 1.465E-02 726 2.129E-03

392 3.483E-05 476 2.486E-03 560 1.302E-02 644 1.426E-02 728 2.008E-03

394 3.708E-05 478 2.540E-03 562 1.334E-02 646 1.386E-02 730 1.896E-03

396 4.050E-05 480 2.647E-03 564 1.366E-02 648 1.345E-02 732 1.787E-03

398 4.537E-05 482 2.793E-03 566 1.399E-02 650 1.303E-02 734 1.688E-03

400 5.423E-05 484 2.976E-03 568 1.431E-02 652 1.262E-02 736 1.590E-03

402 6.656E-05 486 3.194E-03 570 1.463E-02 654 1.220E-02 738 1.501E-03

404 8.637E-05 488 3.430E-03 572 1.495E-02 656 1.178E-02 740 1.413E-03

406 1.183E-04 490 3.689E-03 574 1.527E-02 658 1.136E-02 742 1.331E-03

408 1.702E-04 492 3.972E-03 576 1.558E-02 660 1.094E-02 744 1.258E-03

410 2.473E-04 494 4.264E-03 578 1.589E-02 662 1.054E-02 746 1.187E-03

412 3.536E-04 496 4.555E-03 580 1.618E-02 664 1.013E-02 748 1.120E-03

414 4.929E-04 498 4.853E-03 582 1.648E-02 666 9.728E-03 750 1.057E-03

416 6.742E-04 500 5.150E-03 584 1.676E-02 668 9.336E-03 752 9.963E-04

418 8.861E-04 502 5.426E-03 586 1.702E-02 670 8.944E-03 754 9.403E-04

420 1.135E-03 504 5.691E-03 588 1.726E-02 672 8.571E-03 756 8.866E-04

422 1.417E-03 506 5.955E-03 590 1.749E-02 674 8.199E-03 758 8.369E-04

424 1.748E-03 508 6.199E-03 592 1.771E-02 676 7.862E-03 760 7.904E-04

426 2.106E-03 510 6.432E-03 594 1.791E-02 678 7.513E-03 762 7.452E-04

428 2.496E-03 512 6.662E-03 596 1.807E-02 680 7.187E-03 764 7.062E-04

430 2.922E-03 514 6.879E-03 598 1.822E-02 682 6.859E-03 766 6.653E-04

432 3.371E-03 516 7.092E-03 600 1.834E-02 684 6.548E-03 768 6.286E-04

434 3.833E-03 518 7.316E-03 602 1.843E-02 686 6.249E-03 770 5.926E-04

436 4.314E-03 520 7.527E-03 604 1.850E-02 688 5.952E-03 772 5.599E-04

438 4.831E-03 522 7.740E-03 606 1.854E-02 690 5.671E-03 774 5.288E-04

440 5.378E-03 524 7.961E-03 608 1.855E-02 692 5.389E-03 776 4.989E-04

442 5.938E-03 526 8.185E-03 610 1.853E-02 694 5.125E-03 778 4.715E-04

444 6.442E-03 528 8.413E-03 612 1.848E-02 696 4.866E-03 780 4.460E-04

446 6.793E-03 530 8.652E-03 614 1.840E-02 698 4.620E-03 782 4.223E-04

448 6.876E-03 532 8.894E-03 616 1.829E-02 700 4.383E-03 784 3.987E-04

450 6.668E-03 534 9.149E-03 618 1.816E-02 702 4.149E-03 786 3.784E-04

452 6.193E-03 536 9.405E-03 620 1.798E-02 704 3.934E-03 788 3.583E-04

454 5.564E-03 538 9.673E-03 622 1.778E-02 706 3.719E-03 790 3.385E-04

456 4.926E-03 540 9.947E-03 624 1.755E-02 708 3.523E-03 792 3.209E-04

458 4.361E-03 542 1.024E-02 626 1.730E-02 710 3.332E-03 794 3.030E-04

460 3.900E-03 544 1.053E-02 628 1.703E-02 712 3.157E-03 796 2.869E-04

462 3.559E-03 546 1.082E-02 630 1.672E-02 714 2.985E-03 798 2.720E-04

800 2.575E-04

Absolute Spectral Flux

Page 8: LM-79-08 Test Report for · Spectral Standard OSI 9005- SB #04-05 09/01/2008 (5) A.C. Power Supply Kikusui PCR500M MD003520 Not required A.C. Line Conditioner Elgar 5000B 4924 Not

Page 8 of 12 LM79201306133

Sylvania LED10A19/F/827/RP (Sample 28) Spatial Distribution Photometry

Manufacturer: Sylvania

Lamp: LED10A19/F/827/RP

Lamp Output: 905 lumens

Max Candela: 243.7 at Horizontal: 180°, Vertical: 2°

Input Wattage: 10.16

Luminous Opening: Vertical Cylinder (Dia : 2.18", H: 1.06")

Test: 20134396

Test Date: 6/13/2013

Test Lab: Osram Sylvania ANM NA

Photometry : Type C

Lumens Per Zone

Zone Lumens % Total Zone Lumens % Total

0-5 5.8 0.6% 90-95 19.1 2.1%

5-10 17.3 1.9% 95-100 15.1 1.7%

10-15 28.4 3.1% 100-105 12.1 1.3%

15-20 38.8 4.3% 105-110 9.4 1%

20-25 48.3 5.3% 110-115 7.3 0.8%

25-30 56.3 6.2% 115-120 5.6 0.6%

30-35 62.7 6.9% 120-125 4.2 0.5%

35-40 66.8 7.4% 125-130 3.1 0.3%

40-45 69.0 7.6% 130-135 2.2 0.2%

45-50 68.4 7.6% 135-140 1.5 0.2%

50-55 66.0 7.3% 140-145 1.0 0.1%

55-60 61.2 6.8% 145-150 0.7 0.1%

60-65 55.6 6.1% 150-155 0.4 0%

65-70 48.6 5.4% 155-160 0.2 0%

70-75 42.0 4.6% 160-165 0.1 0%

75-80 35.0 3.9% 165-170 0.1 0%

80-85 29.2 3.2% 170-175 0.0 0%

85-90 23.5 2.6% 175-180 0.0 0%

Zonal Lumen Summary

Zone Lumens % Luminaire

0-30 194.9 21.5%

0-40 324.4 35.8%

0-60 588.8 65.1%

60-90 233.8 25.8%

70-100 163.9 18.1%

90-120 68.6 7.6%

0-90 822.7 90.9%

90-180 82.2 9.1%

0-180 904.9 100%

Page 9: LM-79-08 Test Report for · Spectral Standard OSI 9005- SB #04-05 09/01/2008 (5) A.C. Power Supply Kikusui PCR500M MD003520 Not required A.C. Line Conditioner Elgar 5000B 4924 Not

Page 9 of 12 LM79201306133

Sylvania LED10A19/F/827/RP (Sample 28) Spatial Distribution Photometry (continued) Candela Table - Type C

0 45 90 135 180 225 270 315 360

0 244 244 244 244 244 244 244 244 244

2 244 243 243 243 244 244 244 243 244

4 243 243 243 243 243 243 243 243 243

6 243 242 242 242 243 243 243 242 243

8 242 242 242 241 242 243 242 242 242

10 241 241 241 241 241 242 242 241 241

12 240 240 239 239 240 241 241 240 240

14 239 238 238 238 239 240 240 238 239

16 237 237 237 236 237 238 238 237 237

18 235 235 235 235 236 236 236 235 235

20 233 233 233 232 233 234 234 233 233

22 231 230 230 230 231 232 232 230 231

24 228 228 228 227 228 229 229 228 228

26 225 225 225 224 225 226 226 225 225

28 222 222 221 221 222 223 223 221 222

30 218 218 218 217 218 219 219 218 218

32 214 214 214 213 214 214 215 213 214

34 210 210 209 209 209 210 210 209 210

36 205 205 205 204 204 205 205 204 205

38 200 200 199 199 199 199 200 199 200

40 195 194 194 194 193 193 194 193 195

42 189 188 188 188 187 187 188 187 189

44 183 182 181 182 180 181 181 181 183

46 176 175 175 175 174 175 175 175 176

48 170 169 168 169 167 167 167 167 170

50 162 161 161 161 159 159 160 160 162

52 156 154 154 155 152 152 152 152 156

54 148 147 146 148 145 144 145 145 148

56 141 139 139 140 137 137 137 137 141

58 134 132 131 133 130 129 129 130 134

60 126 124 124 126 122 121 122 122 126

62 119 117 116 118 115 114 114 115 119

64 112 109 109 111 107 106 107 107 112

66 104 102 102 104 100 99 100 100 104

68 98 95 94 97 94 92 93 93 98

70 91 88 88 90 87 86 86 87 91

72 85 82 81 84 81 79 80 80 85

74 79 76 75 78 75 73 74 74 79

76 73 70 70 72 69 68 68 68 73

78 67 65 64 67 63 62 63 63 67

80 62 60 59 62 58 57 58 58 62

82 57 55 54 57 54 53 53 53 57

84 53 51 50 52 49 48 48 49 53

86 49 46 46 48 45 44 44 45 49

88 45 43 42 44 42 40 41 41 45

90 41 39 39 41 38 37 37 38 41

Candela Table - Type C

0 45 90 135 180 225 270 315 360

92 38 36 35 37 35 34 34 35 38

94 35 33 32 34 32 31 31 32 35

96 32 30 30 31 29 28 28 29 32

98 29 28 27 29 27 26 26 27 29

100 27 25 25 26 24 24 24 24 27

102 24 23 23 24 22 22 22 22 24

104 22 21 21 22 21 20 20 20 22

106 21 20 19 20 19 18 18 19 21

108 19 18 18 19 17 17 17 17 19

110 17 16 16 17 16 15 15 16 17

112 16 15 15 16 14 14 14 14 16

114 14 14 14 14 13 13 13 13 14

116 13 13 12 13 12 11 12 12 13

118 12 11 11 12 11 10 11 11 12

120 11 10 10 11 10 10 10 10 11

122 10 10 9 10 9 9 9 9 10

124 9 9 9 9 8 8 8 8 9

126 8 8 8 8 7 7 7 7 8

128 8 7 7 7 7 6 7 7 8

130 7 6 6 7 6 6 6 6 7

132 6 6 6 6 5 5 5 5 6

134 6 5 5 5 5 5 5 5 6

136 5 5 5 5 4 4 4 4 5

138 4 4 4 4 4 4 4 4 4

140 4 4 4 4 3 3 3 3 4

142 4 3 3 3 3 3 3 3 4

144 3 3 3 3 3 3 3 3 3

146 3 3 2 3 2 2 2 2 3

148 2 2 2 2 2 2 2 2 2

150 2 2 2 2 2 2 2 2 2

152 2 2 2 2 2 1 2 2 2

154 2 1 1 1 1 1 1 1 2

156 1 1 1 1 1 1 1 1 1

158 1 1 1 1 1 1 1 1 1

160 1 1 1 1 1 1 1 1 1

162 1 1 1 1 1 1 1 1 1

164 1 1 0 0 1 1 1 1 1

166 1 0 0 0 0 0 1 1 1

168 1 0 0 0 0 0 0 0 1

170 0 0 0 0 0 0 0 0 0

172 0 0 0 0 0 0 0 0 0

174 0 0 0 0 0 0 0 0 0

176 0 0 0 0 0 0 0 0 0

178 0 0 0 0 0 0 0 0 0

180 0 0 0 0 0 0 0 0 0

Page 10: LM-79-08 Test Report for · Spectral Standard OSI 9005- SB #04-05 09/01/2008 (5) A.C. Power Supply Kikusui PCR500M MD003520 Not required A.C. Line Conditioner Elgar 5000B 4924 Not

Page 10 of 12 LM79201306133

Sylvania LED10A19/F/827/RP (Sample 28) Spatial Color Deviation (Goniospectroradiometric Determination)

Average Weighted u', v'

0.260 0.527

Horizontal Vertical Spatial u', v' Du'v'

0 0 0.261 0.525 0.002

0 10 0.261 0.525 0.001

0 20 0.261 0.526 0.001

0 30 0.261 0.526 0.001

0 40 0.261 0.527 0.001

0 50 0.261 0.527 0.001

0 60 0.261 0.528 0.001

0 70 0.260 0.528 0.001

0 80 0.259 0.527 0.001

0 90 0.258 0.526 0.002

0 100 0.256 0.525 0.004

90 0 0.261 0.525 0.002

90 10 0.261 0.525 0.001

90 20 0.261 0.526 0.001

90 30 0.261 0.526 0.001

90 40 0.261 0.527 0.001

90 50 0.261 0.527 0.001

90 60 0.261 0.528 0.001

90 70 0.260 0.527 0.001

90 80 0.259 0.527 0.001

90 90 0.258 0.526 0.003

90 100 0.256 0.525 0.005

Page 11: LM-79-08 Test Report for · Spectral Standard OSI 9005- SB #04-05 09/01/2008 (5) A.C. Power Supply Kikusui PCR500M MD003520 Not required A.C. Line Conditioner Elgar 5000B 4924 Not

Page 11 of 12 LM79201306133

Sylvania LED10A19/F/827/RP (Sample 28) Compliance to Specification for Chromaticity of Solid State Lighting Products

0.28

0.30

0.32

0.34

0.36

0.38

0.40

0.42

0.44

0.46

0.26 0.28 0.30 0.32 0.34 0.36 0.38 0.40 0.42 0.44 0.46 0.48 0.50 0.52

y

x

Nominal CCT CategoriesANSI_NEMA_ANSLG C78.377-2011

2700 K

3000 K

4000 K

6500 K

3500 K

5700 K

Planckian locus

2500 K

3000 K

4000 K

5000 K

6000 K

7000 K

4500 K

5000 K

Page 12: LM-79-08 Test Report for · Spectral Standard OSI 9005- SB #04-05 09/01/2008 (5) A.C. Power Supply Kikusui PCR500M MD003520 Not required A.C. Line Conditioner Elgar 5000B 4924 Not

Page 12 of 12 LM79201306133