lle-b1-st • lle-d1-stlle-b1-st • lle-d1-st installation instructions product safety! this...

8
LLE-B1-ST • LLE-D1-ST Installation Instructions PRODUCT SAFETY ! This product must be installed in accordance with the applicable installation codes by a person familiar with the construction and operation of the product and the hazards involved. To avoid risk of electrical shock, disconnect power before installing, wiring, or servicing the fixture or Digital Light Agent (DLA). ! Do not install fixtures in a vertical or angled orientation. ! Do not apply paint, lubricants, or other coatings to fixture, DLA-LLE, suspension cables, or fasteners. ! Do not use fixture or DLA-LLE if the housing, suspension cables, or optics are damaged. ! Use a damp cloth to clean fixture housing. LLE-B1-ST: 120 - 277 V AC 50/60 Hz 0.29 A maximum LLE-D1-ST: 120 - 277 V AC 50/60 Hz 0.55 A maximum REQUIRED TOOLS: Sticker book template (provided by the project manager) Phillips ® #2 screwdriver Box level (for Standard Aircraft Cable) Mounting screws (for Fixed Mount) INSTALLATION GUIDELINES Some steps, including fixture installation, power/data connection, as well as connection to facility mains power, may vary depending on the project design and conditions. Power and Data Limits A single DLA-LLE can control up to 15 fixtures in a continuous run. Additionally, up to 15 fixtures can share the same power line between each LLE’s internal line voltage harness. To power more than 15 fixtures, introduce a new line voltage connection at the sixteenth fixture. Hardware Spacing and Orientation Fixture orientation must enable correct power and data connections. Fixture spacing must account for DLA-LLEs to be installed after the fixtures are hung, according to the project design. The length of each DLA-LLE module is 2.8 in (7.1 cm) when installed between two fixtures. The length of each LLE fixture is 48.5 in (123.2 cm). 2.8 in (7,1 cm) ! ! Read these instructions before using product. VERIFY THE FIXTURE AND MODULE ORIENTATION Each LLE fixture and DLA-LLE module have two unique ends: Side A and Side B. DLA-LLE Side A: • Receives power from LLE fixture. • Facilitates data connection. Attaches to side A of an LLE fixture. DLA-LLE Side B: • Facilitates data connection. Attaches to side B of an LLE fixture. LLE Side A: • Facilitates data connection. • Facilitates line voltage connection to an adjacent fixture or from the supply circuit. • Attaches to side B of another LLE fixture or DLA-LLE module. LLE Side B: • Provides power to an adjacent DLA-LLE module. • Facilitates data connection. • Facilitates line voltage connection to an adjacent fixture or from the supply circuit. • Attaches to side A of another LLE fixture or DLA-LLE module. Side A Side B ENGLISH

Upload: others

Post on 27-Apr-2020

14 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: LLE-B1-ST • LLE-D1-STLLE-B1-ST • LLE-D1-ST Installation Instructions PRODUCT SAFETY! This product must be installed in accordance with the applicable installation codes by a person

LLE-B1-ST • LLE-D1-STInstallation Instructions

PRODUCT SAFETY! This product must be installed in accordance with the applicable

installation codes by a person familiar with the construction and operation of the product and the hazards involved.

To avoid risk of electrical shock, disconnect power before installing, wiring, or servicing the fixture or Digital Light Agent (DLA).

! Do not install fixtures in a vertical or angled orientation.

! Do not apply paint, lubricants, or other coatings to fixture, DLA-LLE, suspension cables, or fasteners.

! Do not use fixture or DLA-LLE if the housing, suspension cables, or optics are damaged.

! Use a damp cloth to clean fixture housing.

LLE-B1-ST: 120 - 277 V AC 50/60 Hz 0.29 A maximum LLE-D1-ST: 120 - 277 V AC 50/60 Hz 0.55 A maximum

REQUIRED TOOLS:• Sticker book template (provided by the project manager)

• Phillips® #2 screwdriver

• Box level (for Standard Aircraft Cable)

• Mounting screws (for Fixed Mount)

INSTALLATION GUIDELINESSome steps, including fixture installation, power/data connection, as well as connection to facility mains power, may vary depending on the project design and conditions.

Power and Data LimitsA single DLA-LLE can control up to 15 fixtures in a continuous run. Additionally, up to 15 fixtures can share the same power line between each LLE’s internal line voltage harness. To power more than 15 fixtures, introduce a new line voltage connection at the sixteenth fixture.

Hardware Spacing and OrientationFixture orientation must enable correct power and data connections. Fixture spacing must account for DLA-LLEs to be installed after the fixtures are hung, according to the project design. The length of each DLA-LLE module is 2.8 in (7.1 cm) when installed between two fixtures. The length of each LLE fixture is 48.5 in (123.2 cm).

2.8 in (7,1 cm)!

! Read these instructions before using product.

VERIFY THE FIXTURE AND MODULE ORIENTATIONEach LLE fixture and DLA-LLE module have two unique ends: Side A and Side B.

DLA-LLE Side A:• Receives power from

LLE fixture.

• Facilitates data connection.

• Attaches to side A of an LLE fixture.

DLA-LLE Side B:• Facilitates data connection.

• Attaches to side B of an LLE fixture.

LLE Side A:

• Facilitates data connection.

• Facilitates line voltage connection to an adjacent fixture or from the supply circuit.

• Attaches to side B of another LLE fixture or DLA-LLE module.

LLE Side B:

• Provides power to an adjacent DLA-LLE module.

• Facilitates data connection.

• Facilitates line voltage connection to an adjacent fixture or from the supply circuit.

• Attaches to side A of another LLE fixture or DLA-LLE module.

Side A Side B

ENGLISH

Page 2: LLE-B1-ST • LLE-D1-STLLE-B1-ST • LLE-D1-ST Installation Instructions PRODUCT SAFETY! This product must be installed in accordance with the applicable installation codes by a person

2

3. Attach the spring clips to the fixture using the designated holes.

4. Hook the suspension cables to the spring clips.

5. Use a box level to level the fixture.

! Note maximum cable angle.

MAKE POWER AND DATA CONNECTIONSNote: Before making data connections, refer to the sticker book or project plan to identify all assigned control groups. There must be one continuous data line between all fixtures assigned to the same DLA-LLE.

Fixture to Fixture:

1. In accordance with national, state and local electrical codes, gather the line power and control data (yellow/white) cables from each fixture and make the appropriate connections.

60° max.!

ADD TRACKING LABELS TO THE STICKER BOOK1. Detach the plastic bag from the DLA-LLE

module containing the barcode label.

2. Affix the barcode label to the sticker book in accordance with the physical location of the DLA-LLE module in the facility.

3. Repeat for each DLA-LLE module and its assigned fixture run.

Note: Ensure that you have labeled each fixture run clearly as this information is necessary for wiring and data configuration.

INSTALL THE FIXTURESThere are two hanging methods: Fixed Mount and Standard Aircraft Cable. Note: Leave 2.8 in (7.1 cm) between fixtures where DLA-LLE modules will be installed, according to the project design.

Fixed Mount (to surface or unistrut):

1. Refer to the sticker book to confirm the correct location of the fixture.

2. Install both mounting brackets so that they will be equidistant from the center of the fixture, leaving 39.375 ± .375 in (100.1 ± 1.0 cm) between brackets.

3. Secure the fixture to the mounting brackets through the designated handles so that the hardware snaps into place.

4. Center the fixture, then use a Phillips® #2 screwdriver and the provided locking screws to lock the fixture to the brackets.

Standard Aircraft Cable:Note: Each fixture requires at least two suspension cables, two cable fasteners, and two Gripple® spring clips.

1. Refer to the sticker book to confirm the correct location of the fixture.

2. Secure the suspension cables to a beam or truss.

39.375 in ± .375 in100,0 cm ± 1,0 cm

Fixed Mount Locking Screws

Suspension Cable to Beam/Truss

Sticker Book

CONTROLCONTROL

Power (black/red)Alimentacion (negro/rojo)

Data (yellow/white)Datos (amarillo/blanco)

LINE POWERLÍNEA DE ALIMENTACIÓN

Line (brown)Línea (marrón)

Ground (green/yellow)Tierra (verde/amarillo)

Neutral (blue)Neutro (azul)

Page 3: LLE-B1-ST • LLE-D1-STLLE-B1-ST • LLE-D1-ST Installation Instructions PRODUCT SAFETY! This product must be installed in accordance with the applicable installation codes by a person

3

Note: A continuous data bus is required for all fixtures in a DLA-LLE control group. Familiarize yourself with the project design to avoid connecting one fixture to multiple DLA-LLEs.

3. Once all connections are made, hook the tab on Side A of the DLA-LLE onto Side B of the adjacent fixture.

4. Using a Phillips® #2 screwdriver, secure the endplates together with the provided screws.

5. Connect all fixtures and DLA-LLE modules in a fixture run. Make any necessary knockouts (see Connect to Facility Mains Power, page 8) and secure cover plates to fixtures or modules on either end of the fixture run.

CONNECT TO FACILITY MAINS POWER Do not connect or disconnect while under load.

Knockout Locations:

To connect through knockout on top of fixture:

1. Make the appropriate knockout, then use a Phillips® #2 screwdriver to remove the (4x) screws to open the top of the fixture.

2. Identify the power lines that will attach to facility mains power and cut off the modular connector.

Side BSide A

Note: Control power (black/red) cables provide power from a fixture to a DLA-LLE module. If no DLA-LLE is present, tuck the cables into the fixture.

2. Once the power and data lines are connected, hook the tab on Side A of the fixture onto Side B of the next fixture.

3. Using a Phillips® #2 screwdriver, secure the endplates together with the provided screws.

4. Connect all fixtures and DLA-LLE modules in a fixture run. Make any necessary knockouts and secure cover plates to fixtures or modules on either end of the fixture run.

Fixture to DLA-LLE (to Fixture):

1. If connecting line power between two fixtures: In accordance with national, state and local electrical codes, feed the line power cables from the first fixture through the DLA-LLE. Connect to the second fixture.

2. Refer to the project plan to verify the control assignments. Feed one control data (yellow/white) cable through each side of the DLA-LLE, and connect to the adjacent fixture(s). Then, feed the control power (black/red) cable to connect with the appropriate fixture.

Side BSide A

CONTROLCONTROL

Power (black/red)Alimentacion (negro/rojo)

Data (yellow/white)Datos (amarillo/blanco)

LINE POWERLÍNEA DE ALIMENTACIÓN

Line (brown)Línea (marrón)

Ground (green/yellow)Tierra (verde/amarillo)

Neutral (blue)Neutro (azul)

LLE (Top View) Knockout Locations

½ inch trade size

Cover Plate Knockout Locations

Page 4: LLE-B1-ST • LLE-D1-STLLE-B1-ST • LLE-D1-ST Installation Instructions PRODUCT SAFETY! This product must be installed in accordance with the applicable installation codes by a person

4

3. Feed the wires through the knockout and strain relief.

4. In accordance with national, state, and local electrical codes, connect to facility mains power.

5. Replace the fixture top and screws.

To connect through knockout on cover plate:

1. Identify the power lines that will attach to facility mains power and cut off the modular connector.

2. Feed the wires through the knockout and strain relief.

3. In accordance with national, state, and local electrical code, connect to facility mains power.

4. Attach the cover plate by inserting the two bottom tabs to the fixture.

5. Using a Phillips® #2 screwdriver and the provided screws, screw the cover plate to the fixture.

VERIFY THE STICKER BOOKTo prevent issues during commissioning, ensure that the placement of the bar code label in the sticker book corresponds to the DLA-LLE’s physical location in the facility and that the corresponding fixture runs are identified.

Cut modular connector

Page 5: LLE-B1-ST • LLE-D1-STLLE-B1-ST • LLE-D1-ST Installation Instructions PRODUCT SAFETY! This product must be installed in accordance with the applicable installation codes by a person

5

SEGURIDAD DEL PRODUCTO! Este producto se debe instalar conforme al código de instalación

correspondiente y dicha instalación debe estar a cargo de una persona familiarizada con la construcción y la operación del producto y los riesgos involucrados.

Para evitar descargas eléctricas, desconecte la alimentación antes de instalar, cablear o realizar tareas de mantenimiento en el dispositivo o el Digital Light Agent (agente de luz digital, DLA).

! No instale los dispositivos en posición vertical o en ángulo.

! No aplique pintura, lubricantes ni ningún otro recubrimiento al dispositivo, al DLA-LLE, a los cables de suspensión o a los sujetadores.

! No use el dispositivo o el DLA-LLE si la carcasa, los cables de suspensión o la óptica están dañados.

! Use un paño húmedo para limpiar la carcasa del dispositivo.

LLE-B1-ST: 120 - 277 V AC 50/60 Hz 0.29 A maximum LLE-D1-ST: 120 - 277 V AC 50/60 Hz 0.55 A maximum

HERRAMIENTAS NECESARIAS• Plantilla del libro de etiquetas adhesivas (proporcionada por el

director del proyecto)

• Destornillador Phillips® n.º 2

• Caja niveladora (para el cable para aviación estándar)

• Tornillos de montaje (si está colgado mediante un

• montaje fijo)

PAUTAS DE INSTALACIÓNAlgunos pasos pueden variar según el diseño y las condiciones del proyecto (p. ej., la instalación de dispositivos, la conexión de los cables de datos y de alimentación, y la conexión a la red eléctrica en la ubicación física).

Límites de alimentación y datosUn solo DLA-LLE puede controlar hasta 15 dispositivos que funcionen de forma continua. Además, hasta 15 dispositivos pueden compartir la misma línea de alimentación entre los cables de tensión de línea interna del LLE. Para suministrar alimentación a más de 15 dispositivos, instale una nueva conexión de tensión de línea en el decimosexto dispositivo.

Orientación y espaciado del equipo físicoLa orientación del dispositivo debe permitir conectar correctamente los cables de alimentación y de datos. Para la separación de los dispositivos es importante tener en cuenta que, según el plan del proyecto, los módulos DLA-LLE se instalarán después de colgar los dispositivos. La longitud de cada módulo DLA-LLE es de 7,1 cm cuando se instala entre dos dispositivos.

La longitud de cada dispositivo LLE es de 123,2 cm.

! Lea las instrucciones antes de usar el producto.

2.8 in (7,1 cm)!

VERIFICAR LA ORIENTACIÓN DEL DISPOSITIVO Y DEL MÓDULOLos dispositivos LLE y los módulos DLA-LLE tienen cada uno dos extremos únicos, el lado A y el lado B.

Lado A del DLA-LLE:• Recibe alimentación del

dispositivo LLE.

• Facilita la conexión de datos.

• Se conecta al lado A de otro dispositivo LLE.

Lado B del DLA-LLE:• Facilita la conexión

de datos.

• Se conecta al lado B de otro dispositivo LLE.

Lado A del LLE:

• Facilita la conexión de datos.

• Facilita la conexión de voltaje de línea a un dispositivo adyacente o desde el circuito de alimentación.

• Se conecta al lado B de otro dispositivo LLE o módulo DLA-LLE.

Lado B del LLE:

• Suministra alimentación a un módulo DLA-LLE adyacente.

• Facilita la conexión de datos.

• Facilita la conexión de voltaje de línea a un dispositivo adyacente o desde el circuito de alimentación.

• Se conecta al lado A de otro dispositivo LLE o módulo DLALLE.

Lado A Lado B

LLE-B1-ST • LLE-D1-STInstrucciones de instalación

ESPAÑOL

Page 6: LLE-B1-ST • LLE-D1-STLLE-B1-ST • LLE-D1-ST Installation Instructions PRODUCT SAFETY! This product must be installed in accordance with the applicable installation codes by a person

6

Cable para aviación estándar:Nota: Cada dispositivo necesita, por lo menos, dos cables de suspensión, dos sujetadores de cable y dos abrazaderas de resorte Gripple®.

1. Consulte el libro de etiquetas adhesivas para confirmar la ubicación correcta del dispositivo.

2. Asegure los cables de suspensión a la viga o a la armadura de cubierta.

3. Conecte las abrazaderas de resorte al dispositivo mediante los orificios designados.

4. Cuelgue los cables de suspensión a las abrazaderas de resorte.

5. Utilice una caja niveladora para nivelar el dispositivo.

! Tenga en cuenta el ángulo máximo del cable.

CONEXIÓN DE LOS CABLES DE ALIMENTACIÓN Y DE DATOSNota: Antes de realizar conexiones de datos, consulte el libro de etiquetas adhesivas o el plan del proyecto para identificar todos los grupos de control asignados. Debe haber una línea de datos continua entre todos los dispositivos asignados al mismo DLA-LLE.

Fixture to Fixture:

1. Para cumplir con las normativas de electricidad locales, regionales y nacionales, agrupe los cables de la línea de alimentación y de datos de control (amarillo/blanco) de cada dispositivo y realice las conexiones adecuadas.

Suspension Cable to Beam/Truss

60° máx.!

CONTROLCONTROL

Power (black/red)Alimentacion (negro/rojo)

Data (yellow/white)Datos (amarillo/blanco)

LINE POWERLÍNEA DE ALIMENTACIÓN

Line (brown)Línea (marrón)

Ground (green/yellow)Tierra (verde/amarillo)

Neutral (blue)Neutro (azul)

AGREGAR LAS ETIQUETAS DE SEGUIMIENTO EN EL LIBRO DE ETIQUETAS ADHESIVAS

1. Retire la bolsa de plástico del módulo DLA-LLE que contiene la etiqueta del código de barras.

2. Pegue la etiqueta del código de barras al libro de etiquetas adhesivas según la ubicación física del módulo DLA-LLE.

3. Repita la acción para cada módulo DLA-LLE y su serie de dispositivos asignada.

Nota: Asegúrese de haber etiquetado claramente cada serie de dispositivos, ya que esta información es necesaria para la configuración de datos y del cableado.

INSTALAR LOS DISPOSITIVOSHay dos métodos: montaje fijo y cable para aviación estándar. Nota: Deje 7,1 cm de separación entre los dispositivos donde se instalarán módulos DLA-LLE (según el diseño del proyecto).

Montaje fijo (a la superficie o Unistrut):

1. Consulte el libro de etiquetas adhesivas para confirmar la ubicación correcta del dispositivo.

2. Instale ambos soportes de montaje de manera que queden equidistantes desde el centro del dispositivo y deje 100,1 ± 1,0 cm entre los soportes.

3. Fije el dispositivo a los soportes de montaje a través de las manijas designadas de manera que el equipo físico se coloque en su lugar.

4. Centre el dispositivo y fíjelo en los soportes con un destornillador Phillips® n.º 2 y los tornillos de retención.

Libro de etiquetas adhesivas

39.375 in ± .375 in100,0 cm ± 1,0 cm

Tornillos de retención del montaje fijo

Page 7: LLE-B1-ST • LLE-D1-STLLE-B1-ST • LLE-D1-ST Installation Instructions PRODUCT SAFETY! This product must be installed in accordance with the applicable installation codes by a person

7

Nota: Los cables de alimentación de control (negro/rojo) suministran alimentación desde un dispositivo a un módulo DLA-LLE. Si no hay presente un DLA-LLE, introduzca los cables en el dispositivo.

2. Después de conectar las líneas de datos y de alimentación, enganche la pestaña del lado A del dispositivo en el lado B del dispositivo siguiente.

3. Use un destornillador Phillips® n.º 2 para fijar las placas de los extremos con los tornillos suministrados.

4. Conecte todos los dispositivos y los módulos DLA-LLE en una serie de dispositivos. Realice los orificios necesarios y fije las placas de protección en los dispositivos o en los módulos de uno de los extremos de la serie de dispositivos.

Dispositivo a DLA-LLE (a dispositivo):

1. Si se conecta la línea de alimentación entre dos dispositivos: Para cumplir con las normativas de electricidad locales, regionales y nacionales, pase los cables de la línea de alimentación del dispositivo a través del DLA-LLE. Conéctelos al segundo dispositivo.

Lado BLado A

CONTROLCONTROL

Power (black/red)Alimentacion (negro/rojo)

Data (yellow/white)Datos (amarillo/blanco)

LINE POWERLÍNEA DE ALIMENTACIÓN

Line (brown)Línea (marrón)

Ground (green/yellow)Tierra (verde/amarillo)

Neutral (blue)Neutro (azul)

2. Compruebe las asignaciones de control en el plan del proyecto. Pase un cable de datos de control (amarillo o blanco) por cada uno de los lados del DLA-LLE y conéctelos a los dispositivos adyacentes. A continuación, pase el cable de alimentación de control (negro o rojo) para conectarlo al dispositivo adecuado.

Nota: Se requiere un bus de datos continuo para todos los dispositivos que pertenezcan a un grupo de control de DLA-LLE. Familiarícese con el diseño del proyecto para evitar conectar un dispositivo a varios DLA-LLE.

3. Después de completar todas las conexiones, enganche la pestaña del lado A del DLA-LLE en el lado B del dispositivo adyacente.

4. Use un destornillador Phillips® n.º 2 para fijar las placas de los extremos con los tornillos suministrados.

5. Conecte todos los dispositivos y los módulos DLA-LLE en una serie de dispositivos. Realice los orificios necesarios y fije las placas de protección en los dispositivos o en los módulos de uno de los extremos de la serie de dispositivos.

CONEXIÓN A LA RED ELÉCTRICA EN LA UBICACIÓN FÍSICA

No debe conectarse o desconectarse mientras esté en funcionamiento.

Lado BLado A

Ubicaciones de los orificios en el LLE (vista superior)

Tamaño comercial de 1,27 cm

Ubicaciones de los orificios para las placas de protección

Page 8: LLE-B1-ST • LLE-D1-STLLE-B1-ST • LLE-D1-ST Installation Instructions PRODUCT SAFETY! This product must be installed in accordance with the applicable installation codes by a person

5. Atornille la placa de protección al dispositivo con un destornillador Phillips® n.º 2.

VERIFICAR EL LIBRO DE ETIQUETAS ADHESIVASPara evitar inconvenientes durante la puesta en marcha, asegúrese de que la ubicación de la etiqueta del código de barras en el libro de etiquetas adhesivas corresponda a la ubicación física del DLA-LLE en la instalación y de que se hayan identificado las series de dispositivos correspondientes.

Para realizar la conexión a través del orificio en la parte superior del dispositivo:

1. Realice el orificio correspondiente y, a continuación, use un destornillador Phillips® n.º 2 para retirar los 4 tornillos y abrir la parte superior del dispositivo.

2. Identifique las líneas de alimentación que se conectarán a la red eléctrica en la ubicación física y recorte el conector modular.

3. Pase los cables a través del orificio y del protector para cables.

4. Para cumplir con las normativas de electricidad locales, regionales y nacionales, conecte los cables a la red eléctrica en la ubicación física.

5. Sustituya los tornillos y la parte superior del dispositivo.

Para realizar la conexión a través del orificio en la placa de protección:

1. Identifique las líneas de alimentación que se conectarán a la red eléctrica en la ubicación física y recorte el conector modular.

2. Pase los cables a través del orificio y del protector para cables.

3. Para cumplir con las normativas de electricidad locales, regionales y nacionales, conecte los cables a la red eléctrica en la ubicación física.

4. Para sujetar la placa de protección, inserte las dos pestañas inferiores en el dispositivo.

Cut modular connector

www.digitallumens.com374 Congress Street, Suite 600Boston, MA USA 02210+1 (617) 723-1200

All Rights Reserved © 2010-2016Digital Lumens Incorporated

Subject to change without notice.DOC-000279-01 Rev B 08-2016

Importador mexicanoH20 Arquitecteros

Nuevo León #501 ACol. Alameda

Celaya, GuanajuatoMéxico C.P. 38050

Tel.: +52 (461) 613 3751