Remote Programming Software LITE (RPS-LITE)D5500CU-LITE

en Release Notes

Introduction

About documentationCopyrightThis document is the intellectual property of Bosch Security Systems, Inc. and is protected bycopyright. All rights reserved.

TrademarksAll hardware and software product names used in this document are likely to be registeredtrademarks and must be treated accordingly.

1

1.1

Remote Programming Software LITE(RPS-LITE)

Introduction | en 3

Bosch Security Systems, Inc. Release Notes 2013.09 | 08 | F01U045286

Release notes

Version 5.17 compatibilityRPS-LITE supports the following control panels:– B5512/B4512/B3512– D6412/D4412– D9112B1/D7212B1– D8112G2 and D8112E1– D9412GV4/D7412GV4/D7212GV4, D9412GV3/D7412GV3/D7212GV3, D9412GV2/

D7412GV2/D7212GV2, D9412G/D7412G/D7212G, D9412/D7412/D7212, D9112. Tocreate an account in RPS for either a D9412G or D7412G control panel, use theD9124default.dsf file on the RPS-LITE CD-ROM to create a D9124 account. Use theD7212G default.dsf file on the RPS-LITE CD-ROM to create a D7212G account.

Depending on your installation, some of these control panels might not be accessible.

Version 5.17 enhancements– Diagnostics changes to support virtual output states. Refer to the help files for

information about virtual points and outputs.– The Monthly Test Report has been changed to Send Test Report where the options are

Scheduled, Hourly, or Monthly.– Add support for Show Date and Time parameter which will be an added feature in future

keypads.

B5512/B4512/B3512 control panel highlights– ULC list for:

– ULC C1023 - Household Burglar Alarm System Units– ULC C1076 - Proprietary Burglar Alarm Units and System– ULC S303 - Local Burglar Alarm Units and System– ULC S304 - Central and Monitoring Station Burglar Alarm Units– ULC S545 - Residential Fire Warning System Control Units

– RPS-LITE now fully supports the new B3512 control panel.– Output text descriptions are now transferred to the control panel for display at the

keypad or as part of the central station reports.– English, Spanish, French, and Portuguese languages are available for the primary or

secondary languages on the keypads.– Personal notification parameter settings are grouped together, different methods of SMS

and email delivery are available, and the control panel can now send messages in thelanguage of choice.

– Email Server Configuration parameters are available to support the setup of an SMTPemail server for routing emails to a personal notification destination.

– A, B, and C on-board outputs are available within custom functions. A, B, and C areequivalent to outputs 1, 2, and 3 respectively.

– SDI2 module firmware can be updated in the same fashion as panel firmware updates byimporting a firmware file and using the firmware update wizard for control panels withversion 2.01 firmware.

– A feature called Nightlight Enable illuminates the display and the keys on the keypadwhen the keypad is idle. This feature requires a compatible control panel with a firmwarerevision of 2.01 and a keypad with a firmware revision of 1.02 or higher.

2

2.1

2.2

2.2.1

4 en | Release notesRemote Programming Software LITE

(RPS-LITE)

2013.09 | 08 | F01U045286 Release Notes Bosch Security Systems, Inc.

– Keypads with four integrated points can be configured as a point source starting at pointboundaries 11, 21, 31, etc.

– Diagnostics changes support virtual output states. Refer to RPS Help for informationabout virtual points and outputs.

– The Monthly Test Report is now called Send Test Report with scheduled, hourly, ormonthly options.

– The control panel includes support for the Show Date and Time parameter which will bean added feature in future keypads.

– Guided configuration is available for Poll Rate, ACK Wait Time, and Retry Count.

GV4 Series v2.00 and higher control panel highlights– ULC list for:

– ULC C1023 - Household Burglar Alarm System Units– ULC C1076 - Proprietary Burglar Alarm Units and System– ULC S303 - Local Burglar Alarm Units and System– ULC S304 - Central and Monitoring Station Burglar Alarm Units– ULC S545 - Residential Fire Warning System Control Units

– Support for 37 bit card types have been added to the GV3 and GV4 panels. This wasadded to support 37 bit Wiegand HID H10302 cards.

– SDI2 module firmware can be updated in the same fashion as panel firmware updates byimporting a firmware file and using the firmware update wizard for control panels withversion 2.01 firmware.

– A feature called Nightlight Enable illuminates the display and the keys on the keypadwhen the keypad is idle. This feature requires a compatible control panel with a firmwarerevision of 2.01 and a keypad with a firmware revision of 1.02 or higher.

– Keypads with four integrated points can be configured as a point source starting at pointboundaries 11, 21, 31, etc.

– Diagnostics changes support virtual output states. Refer to RPS Help for informationabout virtual points and outputs.

– The Monthly Test Report is now called Send Test Report with scheduled, hourly, ormonthly options.

– The control panel includes support for the Show Date and Time parameter which will bean added feature in future keypads.

– Guided configuration is available for Poll Rate, ACK Wait Time, and Retry Count.

Version 5.17 installation notes– Directory Installation. Do not install RPS-LITE in a directory with a space in its name (for

example, “Program Files”).– Update Operating System Message when Installing SQL Express. If you install SQL

Express on any non-English version of Windows XP SP3, a dialog might appearrecommending you to update your operating system. This message can be ignored. ClickOK to continue installing SQL Express.

2.2.2

2.3

Remote Programming Software LITE(RPS-LITE)

Release notes | en 5

Bosch Security Systems, Inc. Release Notes 2013.09 | 08 | F01U045286

– Cannot Update System File Message when Installing SQL Express. When installing SQLExpress on a non-English version of Windows XP SP3, the following error message mightappear:

“The Windows Installer service cannot update the system file C:\WINDOWS\system32\msxml6r.dll because the file is protected by Windows.”If this error message appears, cancel the installation and perform the following steps:Make a backup copy of the system registry. Navigate to the registry key on the RPS-LITE CD-ROM at X:\Windows File Protection Registry Update. “X” refers to the letter assigned to thecomputer’s CD-ROM drive. Double-click the WindowsFileProtection.reg file. Restart thecomputer and reinstall SQL Express.– Corrupt Account Database on a Turkish Operating System. If you change the original

settings of the RPS-LITE computer after installing RPS-LITE on a Turkish version of asupported Windows operating system, the account database will become corrupted.

Version 5.17 operation notes– Creating a GV4 Series control panel account. When creating a new GV4 Series control

panel account in RPS, be sure to select the correct firmware version on the Panel Infotab on the Panel Data – New window.

Figure 2.1: GV4 Panel Version (v1.00 thru v1.99 or v2.00 or greater)

– Upgrading a GV4 v1.x account to a GV4 v2.0 account. Important: You cannot upgradeD7212GV4 v1.x accounts. If you upgrade a D7412GV4 v1.x or a D9412GV4 v1.x to a v2.0control panel you must keep in mind that these panels no longer support the sameperipherals. You must review the results of the conversion in detail. Affected itemsinclude point indexes and custom functions.

– Firmware Update a GV4 v1.x account to GV4 v2.0 account. Due to the fundamentaldifferences in the firmware between the GV4 v1.x and GV4 v2.0 it is important to followthe process below. Note that after update of firmware from v1.x to v2.0 the configurationvalues are set to the defaults.

Updating RPS and importing the firmware file:1. Install RPS v5.17.2. To import the new firmware into RPS, from the Main menu, select Config > System.

Select the Firmware Files tab, and then click Import.3. Click the Select Firmware File ellipsis (browse) button, and then browse to and select

the firmware file to upload.4. Click Open and then Next. When the import finishes, click Finish.Creating a backup of the control panel account:

2.4

6 en | Release notesRemote Programming Software LITE

(RPS-LITE)

2013.09 | 08 | F01U045286 Release Notes Bosch Security Systems, Inc.

1. From the Panel List window, click New.2. To create a new control panel account from one currently in the Panel List, from the New

Panel window, click the Existing tab. Select the control panel account from the list ofexisting panels, and click OK.

3. Fill in the appropriate parameters to create the GV4 Version 1.x control panel accountand click OK.

Updating the control panel firmware:1. Open the new GV4 v1.x control panel account and connect to the control panel using a

high speed connection. Do not use a phone connection.

2. Click the Firmware Update Wizard icon. The Firmware Update Wizard opens.3. Click Next, and then select the correct firmware file. Click Next.4. Select the Acknowledge to Continue check box and click Next to begin the update.

When the update finishes, the Disconnecting from the Control Panel message appears.

5. Click Close. The control panel reboots.6. Close the control panel account.Updating and sending programming to the control panel:1. Highlight the updated control panel account in the Panel List, and then right-click the

account and select View.2. In the control panel Data View window, click Edit, and then from the Panel Type drop

down list, select the correct control panel type with [V2.00 or greater] (i.e. D9412GV4v2.00 or greater), and then click OK.

3. Prior to sending data to the control panel, confirm the new, automatically changedconfiguration values match those needed for the control panel. Make any necessarychanges.

4. Open the Version 2.00 control panel account and click the Connect icon. The PanelCommunication dialog box appears.

5. Temporarily change the passcode in the RPS Passcode text box to 999999, and clickConnect. (On the next connection, you will not need to change the passcode to connectto the panel (the account’s passcode is used.)

6. The Panel Sync dialog box appears.7. Select Send ALL Updated RPS Data to Panel and click OK. Note: Do not select Receive

Panel Data.8. The firmware update completes and you can exit RPS.9. Test the control panel for operation.For more information on changed configuration values, refer to GV4 v1.x to GV4 v2.0conversion issues, page 8.

Remote Programming Software LITE(RPS-LITE)

Release notes | en 7

Bosch Security Systems, Inc. Release Notes 2013.09 | 08 | F01U045286

– Creating a GV3 Series control panel account: When creating a new GV3 Series controlpanel account in RPS, be sure to select the correct firmware version on the Panel Infotab on the Panel Data – New window.

Figure 2.2: GV3 Panel Version (v8.00 thru v8.09 or v8.10 or greater)

GV4 v1.x to GV4 v2.0 conversion issues– Cannot convert v1.x custom functions. Due to the enhanced formatting for custom

functions, RPS cannot convert v1.x custom functions in an updated account. Recreate thefunctions after update.

– Point Indexes and Point Types differences.– Fire point has been removed as a Point Index, it is now a Point Type. When a Point

Index with Fire Point = Yes is detected in a from GV4 v1.x control panel account, thePoint Type for that Point Index is changed to Point Type = Fire Point.

– Some Point Types that are no longer supported: D279 (O/C Non-Priority), D279 (O/CNon-Priority), and Easikey. When these point types are detected in a GV4 v1.x controlpanel account, they are converted to Point Type = 24-Hour.

– Supported printers. The D9131 Parallel Printer Interface is no longer supported..

Version 5.17 known issues– When setting View/Edit levels for User Passcodes, it is recommended that this level is

also configured at the same level as Mask User Passcode. If you have used a View/Editlevel higher than the Mask User Passcode, it is possible for a user with a level below theView/Edit level to view user passcodes through panel reports. This will be resolved in thenext release of RPS-LITE

– Gas Alarms and Gas Trouble indications are not properly displayed in RPS diagnostics.They are, however, properly reported to the Central Station, shown at keypads, andcommunicated in the automation protocol. This issue will be resolved in the next releaseof RPS-LITE

– Support for B5512/B4512/B3512 USB direct connect. USB direct connect uses a serialport assignment on the connected computer. RPS-LITE only supports COM ports 1through 16. If Windows automatically assigns a COM port higher than 16, reassign a COMport previously assigned but no longer in use (Windows might present an unused COMport as still in use). Refer to release com ports in Microsoft's technical forums at http://social.technet.microsoft.com/Forums/en-US/w7itprohardware/thread/e1ba4f5e-af63-40e5-855a-c513f5013ec6.

– For the B5512/B4512/B3512 on-board USB connection, the USB drivers might notautomatically install when you connect the USB cable from the computer to the controlpanel. When you connect the USB for the first time, the Found New Hardware (NotResponding) dialog box might appear, depending on the operating system. If it does, clickthe Locate and install driver software (recommended) option. Windows locates thedrivers automatically; RPS installs the drivers in the proper folder with the other USBdrivers. Notice! The RPS-LITE USB driver is named USB, RPS to Bosch ST-IN CP. Onceconfigured, the computer remembers the proper configuration the next time you connectthe control panel using USB. When installed properly, the USB driver is listed in theDevice Manager under Ports (COM & LPT).

2.4.1

2.5

8 en | Release notesRemote Programming Software LITE

(RPS-LITE)

2013.09 | 08 | F01U045286 Release Notes Bosch Security Systems, Inc.

– Modem baud rate for GV4 Series and B Series control panels. D9412GV4/D7412GV4 andB5512/B4512/B3512 control panels can communicate via Modem at 2400 baud rate, butthe UOM operation only communicates at 1200 baud. RPS-LITE operates in UOM modewith only one baud rate, and to be backward compatible with older control panels, RPS-LITE uses 1200 baud. When setting a control panel for UOM, configure PANEL WIDEPARAMETERS > RPS Parameters > RPS Modem Speed to 1200.

Operating system known issues– Windows Server 2003 Win Installer 3.1 Error Message. During the installation of RPS-LITE,

Win Installer 3.1 shows a failed installation message when installing RPS-LITE on aWindows Server 2003 computer.

– Windows 7 DX4010V2 Driver Update. When upgrading an existing version of the RPS-LITEon a Windows 7 computer, the driver for the DX4010V2 does not automatically update tothe latest version. If it is required, manually install the file now located on the CD.

RPS operation known issues– Firmware version shows after refresh. After firmware update, the Panel View window

does not immediately show the correct firmware value. Press [F5] to refresh the screento display the correct firmware version.

– Language Settings for Windows Users Without Admin Rights. If a Windows user who doesnot have admin rights on the RPS-LITE computer changes the default language setting(for example, from English to Spanish), the change is not preserved when RPS-LITE isclosed and restarted. The setting reverts to the default language.

– Changing the Computer’s Regional Settings Affects Date Displays. If you change yourRPS-LITE computer’s regional settings, some date displays might not appear correctly.

– Invalid Messages. Some modems can cause RPS-LITE to generate an invalid RPS-LITEpasscode message as a result of a busy phone line. Calling an invalid control panel type(for example, a D7024 account calling a D6412 control panel) does not always cause RPSto generate an Invalid Panel Type error message. An Invalid RPS Passcode message mightappear instead.

– RPS-LITE and Door Access Control Module (DACM) Software Compatibility. If you installRPS-LITE and the DACM software on the same computer, the DACM software might notstart. Uninstall the DACM software, and then reinstall it.

– Importing Accounts from Older Versions of RPS-LITE. Accounts imported from olderversions of RPS-LITE do not appear in the Panel List regardless of a successful importmessage from RPS. This issue applies only to non-English versions of RPS-LITE installedon compatible Microsoft Windows operating systems.

– Extended Desktop Monitor Configuration. When using an Extended Desktop monitorconfiguration, some of the dialog boxes and windows do not retain their last usedlocation. If you change from Extended Desktop to a Single monitor, some windowsattempt to open on the extended monitor.

Unattended Service known issues– Windows Users Without Admin Rights Cannot Turn Unattended Service On or Off.

Windows users who do not have admin rights on the RPS-LITE computer cannot turnUnattended Service on or off.

2.5.1

2.5.2

2.5.3

Remote Programming Software LITE(RPS-LITE)

Release notes | en 9

Bosch Security Systems, Inc. Release Notes 2013.09 | 08 | F01U045286

– UOM and Hayes 1200 Modem. Starting with RPS-LITE 5.13, the Hayes 1200 Modem is nolonger supported for Unattended Over Modem (UOM) operation.

– UOM Init String for a GV3 Series or DS7400XiV4 Account. When using Unattended OverModem (UOM) with a GV3 Series or DS7400XiV4 control panel account, use the modeminit string for the DS7400XiV4 control panel.

– Panel-Initiated Unattended Over Network (PI-UOM/UON). Changes trigger UnattendedService to run unexpectedly. After a panel-initiated UOM/UON change, the UnattendedService runs without alerting the RPS-LITE operator.

– Intermittent Connection over IP and “U Comm Failure” Message. If there is anintermittent connection over IP, the control panel and RPS-LITE can becomeunsynchronized during a data Send. If this occurs, RPS-LITE logs a "U Comm Failure"message in the Activity List. There is no visible indication (at the control panel or RPS)other than the "U Comm Failure" message that indicates that the data send did not finishproperly.

– Baud Rates for Panel-initiated Unattended Over Modem (PI-UOM). PI-UOM can only use1200 baud. Baud rates of 300 and 2400 are currently not supported.

RPS printing known issues– Printing the Program Record Sheet (PRS). RPS-LITE might add extra blank pages when

printing the PRS to the .rtf file format. Some PRS reports printed in .pdf or .rtf formatmight show unaligned data.

– RPS-LITE Uses Default Printer for All But First Report in Multiple Report Group. Whenprinting multiple control panel reports, RPS-LITE sends only the first report to a selectedprinter other than the default printer. All subsequent reports in the request are sent tothe default printer.

– Resizing Saved Exported Reports. To print a saved exported file correctly, some manualresizing might be required for the selected printer.

D9412GV2/GV3, D7412GV2/GV3, D7212GV2/GV3 known issues– GV3 Series v8.10 or greater and Hayes or Securcomm Modem Baud Rate Settings. If you

set the baud rate in the control panel and in the RPS Panel Communication Window to2400 and you receive either an Invalid RPS Passcode or Retry count exceeded message,reset the baud rate to 1200 in both RPS and the control panel.

– Online Diagnostics Area Tab (D7212GV2/GV3 only). The Diagnostics Area Tab for theD7212GV2 and GV3 accounts displays eight areas. The D7212GV2/GV3 control panelsonly support four areas.

– Master Armed Instant Status (Area Tab). RPS-LITE only displays the current status forMaster Armed Instant in the Area tab. RPS cannot send this command to the controlpanel.

– Ground Fault Restoral Event. RPS-LITE does not show this event as a Ground FaultRestoral event in the History List details. In the Events column, RPS-LITE shows “RestoralReport.” In the Details column, RPS-LITE shows “Area 1 Point N/A.”

– Routing Selections do not Match Diagnostic Reports Selections. To enable all DiagnosticReports or disable Diagnostic Reports for Route Groups 1 through 4, select Yes or No forthat category from PANEL-WIDE PARAMETERS > Routing. The only time you shouldselect specific reports from PANEL-WIDE PARAMETERS > Routing > Diagnostic Reportsis when you want to enable some diagnostic reports but not all. All Diagnostic Reportsselections made from that location appear as “Custom” in the corresponding RouteGroup.

2.5.4

2.5.5

10 en | Release notesRemote Programming Software LITE

(RPS-LITE)

2013.09 | 08 | F01U045286 Release Notes Bosch Security Systems, Inc.

– Invalid Relay Parameter Entries in Upgraded Accounts (D7212GV2 only). An upgradedD7212GV2 account might contain invalid entries if the original D7212 or D7212G accountcontained a value between 25 and 64 in any of the relay parameters. The valid range forD7212GV2 relay parameters is 0 to 24, except for the Silent Alarm relay parameter. Thisparameter also allows additional entries of 60, 63, and 64 as alternate functions.

– Panel Sync Window Appears When Control Panel and RPS are Synchronized (GV2 only).The Panel Sync Window might appear even if the control panel account and RPS aresynchronized.

– RPS-LITE Override of Control Panel High Security Features. For high security applications,the control panel provides features such as Two-Man Rule and Early Ambush that requiretwo valid passcode entries to disarm an area. Disarming an area through the RPSDiagnostic window overrides these high security features without alerting the RPS-LITEoperator.

Miscellaneous– Use the D9124default.dsf file on the RPS CD-ROM to create a D9124 account.– To create an account in RPS-LITE for either a D9412G or D7412G control panel, use

either the D9412 or D7412 control panel type.– Use the D7212G default.dsf file on the RPS CD-ROM to create a D7212G account.

2.6

Remote Programming Software LITE(RPS-LITE)

Release notes | en 11

Bosch Security Systems, Inc. Release Notes 2013.09 | 08 | F01U045286