listing constructional data report (cdr) - logitech · electrical wires factory ... specifically...

31
Listing Constructional Data Report (CDR) Report Number 13070799HKG-001 Original Issued: 5-Sep-2013 Revised: None Standard(s) Applicant Manufacturer Address Address Country Country Contact Contact Phone Phone FAX FAX Email Email 1.0 Reference and Address Logitech Inc. 86-769- 2208 2611 Grant Bowen / Mitchell Philipi Mr. Ben Ng USA (360) 817-1331 Information Technology Equipment – Safety – Part 1: General Requirements (UL 60950-1 Second Edition rev. December 19, 2011 and CAN/CSA C22.2 No.60950-1-07 Second Edition, rev. December 19, 2011) Entirely Replaces Report Number SZ09040028-1 Tai Sing Industrial Road, Bai Zhou Bian Village, Dong Cheng, Dongguan City, Guangdong Province 523113 (360) 817-1200 86-769- 2208 2859 4700NW Camas Meadows Drive Camas, WA 98607, China Dongguan Tai Sing Audio Technology Ltd. [email protected] [email protected] Page 1 of 31

Upload: vulien

Post on 28-Aug-2018

243 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: Listing Constructional Data Report (CDR) - Logitech · Electrical Wires Factory ... specifically described in the text of this report are also acceptable as internal wiring terminals

Listing Constructional Data Report (CDR)

Report Number 13070799HKG-001 Original Issued: 5-Sep-2013 Revised: None

Standard(s)

Applicant Manufacturer

Address Address

Country CountryContact ContactPhone PhoneFAX FAXEmail Email

1.0 Reference and Address

Logitech Inc.

86-769- 2208 2611

Grant Bowen / Mitchell Philipi Mr. Ben NgUSA

(360) 817-1331

Information Technology Equipment – Safety – Part 1: General Requirements(UL 60950-1 Second Edition rev. December 19, 2011 and CAN/CSA C22.2 No.60950-1-07 Second Edition, rev. December 19, 2011)

Entirely Replaces Report Number SZ09040028-1

Tai Sing Industrial Road, Bai Zhou Bian Village, Dong Cheng, Dongguan City, GuangdongProvince 523113

(360) 817-1200 86-769- 2208 2859

4700NW Camas Meadows DriveCamas, WA 98607,

China

Dongguan Tai Sing Audio Technology Ltd.

[email protected]@logitech.com

Page 1 of 31

Page 2: Listing Constructional Data Report (CDR) - Logitech · Electrical Wires Factory ... specifically described in the text of this report are also acceptable as internal wiring terminals

Report No. 13070799HKG-001Logitech Inc.

Page 2 of 31 Issued: 5-Sep-2013Revised: None

Product Brand name

ModelsModel Similarity

Ratings

Other Ratings

2.0 Product Description

Speaker System Z313Logitech

N.A.

N.A.

AC120V 60Hz 208mA, Class II

DescriptionThe products covered by this report is Speaker System Z313 provided with non-detachable power cordset and polarized attachment plug NEMA 1-15P.

S-00093

ED 16.3.15 (1-Jan-13) Mandatory

Page 3: Listing Constructional Data Report (CDR) - Logitech · Electrical Wires Factory ... specifically described in the text of this report are also acceptable as internal wiring terminals

Report No. 13070799HKG-001Logitech Inc.

Page 3 of 31 Issued: 5-Sep-2013Revised: None

Photo 1 - Front view

Photo 2 - Bottom and rear view

3.0 Product Photographs

1

2 34

11

ED 16.3.15 (1-Jan-13) Mandatory

Page 4: Listing Constructional Data Report (CDR) - Logitech · Electrical Wires Factory ... specifically described in the text of this report are also acceptable as internal wiring terminals

Report No. 13070799HKG-001Logitech Inc.

Page 4 of 31 Issued: 5-Sep-2013Revised: None

3.0 Product Photographs

Photo 3 - Satellite Speaker View

Photo 4 - Internal View

6, 12

5

13

ED 16.3.15 (1-Jan-13) Mandatory

Page 5: Listing Constructional Data Report (CDR) - Logitech · Electrical Wires Factory ... specifically described in the text of this report are also acceptable as internal wiring terminals

Report No. 13070799HKG-001Logitech Inc.

Page 5 of 31 Issued: 5-Sep-2013Revised: None

3.0 Product Photographs

Photo 5 - Component side View

Photo 6 - PCB layout View

8 7

T4AL, 125V

ED 16.3.15 (1-Jan-13) Mandatory

Page 6: Listing Constructional Data Report (CDR) - Logitech · Electrical Wires Factory ... specifically described in the text of this report are also acceptable as internal wiring terminals

Report No. 13070799HKG-001Logitech Inc.

Page 6 of 31 Issued: 5-Sep-2013Revised: None

3.0 Product Photographs

Photo 7 - Internal View for single rectified board separate from alternative amplified board

Photo 8 - PCB layout View for single rectified board separate from alternative amplified board

T4AL, 125V

ED 16.3.15 (1-Jan-13) Mandatory

Page 7: Listing Constructional Data Report (CDR) - Logitech · Electrical Wires Factory ... specifically described in the text of this report are also acceptable as internal wiring terminals

Report No. 13070799HKG-001Logitech Inc.

Page 7 of 31 Issued: 5-Sep-2013Revised: None

3.0 Product Photographs

Photo 9 - Component side View for alternative amplified board

Photo 10 - PCB layout View for alternative amplified board

ED 16.3.15 (1-Jan-13) Mandatory

Page 8: Listing Constructional Data Report (CDR) - Logitech · Electrical Wires Factory ... specifically described in the text of this report are also acceptable as internal wiring terminals

Report No. 13070799HKG-001Logitech Inc.

Page 8 of 31 Issued: 5-Sep-2013Revised: None

3.0 Product Photographs

Photo 11 - Transformer construction

ED 16.3.15 (1-Jan-13) Mandatory

Page 9: Listing Constructional Data Report (CDR) - Logitech · Electrical Wires Factory ... specifically described in the text of this report are also acceptable as internal wiring terminals

Report No. 13070799HKG-001Logitech Inc.

Page 9 of 31 Issued: 5-Sep-2013Revised: None

Ph

oto

#

Item

no.1 NameManufacturer/

trademark2 Type / model2Technical data and securement means

Mark(s) of

conformity3

1 1 Power cordset Various NISPT-2300V, VW-1, 105°C, 18AWG x 2C, with plug configuration NEMA 1-15P, 10A, 125V.

cULus

2 2Wooden enclosure

Various VariousPressing wood with dimension 220 x 150 x 220 mm, min. thickness 9.0 mm, fixed by glue.

NR

2 3 Subwoofer Various Various4Ω, 15W, fixed on bottom enclosure.

NR

2 4Plastic material of rear enclosure

Formosa Chemicals & Fibre Corp Plastics DIV

HP8250 50°C, HB, Min. thickness: 2.6 mm cURus

3 5 Satellite Speaker Various Various 4Ω, 5W, 2pcs provided. NR

4 6 Mains transformerEastern Frontier Co., Ltd

2-9524T

EI-57. Rated input: 120 Vac, 60 Hz; Output: 13.5 V, 1900 mA, fixed by 2 screws on bottom inside of enclosure, Pri. winding: Ф0.27 mm x 740Ts, Sec. winding: Ф0.7 mm x 96Ts.

NR

4 6A BobbinEI Dupont De Nemours & Co Inc

101F(+)(f1)V-2, 130°C, Min. thickness: 0.7 mm.

cURus

Ta Win Industries (M) SDN BHD

UEW 130°C URus

Various Various 130°CURus or cURus

Dongguan Shin Yahua Electronic Material Co Ltd

PZ 130°C URus

Jingjiang Yahua Pressure Sensitive Glue Co Ltd

PZ 130°C URus

4 6D Thermal linkAUPO Electronics Ltd

A5-F 250V, 2A, 135°C cURus

Hang Lee Industrial Co

1672 300V, VW-1, 105°C, 22AWG cURus

Various 1672 300V, VW-1, 105°C, 22AWG cURusHang Lee Industrial Co

1015 600V, VW-1, 105°C, 20AWG cURus

Various 1015 600V, VW-1, 105°C, 20AWG cURus

Tai Ping Circuits Technology Ltd

Various 130°C, V-0 URus

Various Various 130°C, V-0 URusHollyland Co Ltd 51S, 51S(P) 125V, T 4A L, soldered on PCB cULusVarious Various 125V, T 4A L, soldered on PCB cULus

5 7 All PCB

5 8 Current fuse

4 6E Pri. Lead wire

4 6F Sec. Lead wire

4 6B Magnet wire

4 6C Insulation tape

4.0 Critical Components

ED 16.3.15 (1-Jan-13) Mandatory

Page 10: Listing Constructional Data Report (CDR) - Logitech · Electrical Wires Factory ... specifically described in the text of this report are also acceptable as internal wiring terminals

Report No. 13070799HKG-001Logitech Inc.

Page 10 of 31 Issued: 5-Sep-2013Revised: None

Ph

oto

#

Item

no.1 NameManufacturer/

trademark2 Type / model2Technical data and securement means

Mark(s) of

conformity3

4.0 Critical Components

5 9Heat sink (not shown)

Various VariousMetallic, Min. Thickness: 1.0 mm, with dimenstion 86 mm (W) x 120 mm (L) x 25 mm (H)

NR

Changyuan Electronics (Shenzhen) Co Ltd

Changbao102, CB-HFT

125°C, 600V, VW-1 cURus

Shenzhen Woer Heat-shrinkable Material Co., Ltd

RSFR-H 125°C, 600V, VW-1 cURus

4 11Bushings, incorporating a strain relief

Heavy Power Co., Ltd.

4K-4For UL wire accommodated SPT-2 with mounting hole 12.7 - 13.1 X 11.8mm, lrngth 10.3mm.

cURus

4 12Alternative Mains transformer

Kings Electric Co., Ltd.

H10080

Rated input: 120Vac, 60Hz; EI48Loaded voltagae: 13.5V, 1900mA,Unloaded voltage: AC15.5V, fixed by 2 screws on bottom inside of enclosure, Pri. Winding: Ø0.25mm x 660Ts, Secondary winding: Ø0.7mm x 85Ts.This transformer for for construction in photo 7 - 10 only.

NR

4 12aBobbin of Transformer

EI Dupont De Nemours & Co., Inc

101FMin 0.7 mm thickness, rated V-2, 130°C.

URus

Jingjiang Yahua Pressure Sensitive Glue Co., Ltd.

PZ

Teraoka Seisakusho Co., Ltd.

631S #25(A)*

Aupo Electronics Ltd.

A4-F

Xiamen Set Electronics Co., Ltd.

K4

Hong Hu Bluelight Electronic Co., Ltd.

RH 130-2

Humen Xintai Electrical Wires Factory

1672

Various Various

Humen Xintai Electrical Wires Factory

1015

Various Various

Secondary lead wire

5 10Heat shrinkable tube (not shown)

Insulation Tape12b

rated 300V, VW-1, Min. 20AWG, Min. 105°C.

rated 300V, VW-1, Min. 22AWG, Min. 105°C.

Primary lead wire

Thermal Fuse AC 250V 2A 130°C

URus

URus

cURus

12e4

Polyethylene terephthalate film insulating tape 130°C with flame retardent.

4

12c4

12d4

ED 16.3.15 (1-Jan-13) Mandatory

Page 11: Listing Constructional Data Report (CDR) - Logitech · Electrical Wires Factory ... specifically described in the text of this report are also acceptable as internal wiring terminals

Report No. 13070799HKG-001Logitech Inc.

Page 11 of 31 Issued: 5-Sep-2013Revised: None

Ph

oto

#

Item

no.1 NameManufacturer/

trademark2 Type / model2Technical data and securement means

Mark(s) of

conformity3

4.0 Critical Components

4 13Closed-End connector

Heavy Power Co., Ltd.

CE2 rated 600V 105°C URus

2) “Various“ means any type, from any manufacturer that complies with the "Technical data and securement means" and meets the "Mark(s) of conformity" can be used.

3) Indicates specific marks to be verified, which assures the agreed level of surveillance for the component. "NR" - indicates Unlisted and only visual examination is necessary. "See 5.0" indicates Unlisted components or assemblies to be evaluated periodically refer to section 5.0 for details.

NOTES:

1) Not all item numbers are indicated (called out) in the photos, as their location is obvious.

ED 16.3.15 (1-Jan-13) Mandatory

Page 12: Listing Constructional Data Report (CDR) - Logitech · Electrical Wires Factory ... specifically described in the text of this report are also acceptable as internal wiring terminals

Report No. 13070799HKG-001Logitech Inc.

Page 12 of 31 Issued: 5-Sep-2013Revised: None

No Unlisted CEC components are used in this report.

5.0 Critical Unlisted CEC Components

ED 16.3.15 (1-Jan-13) Mandatory

Page 13: Listing Constructional Data Report (CDR) - Logitech · Electrical Wires Factory ... specifically described in the text of this report are also acceptable as internal wiring terminals

Report No. 13070799HKG-001Logitech Inc.

Page 13 of 31 Issued: 5-Sep-2013Revised: None

2. Mechanical Assembly - Components such as switches, fuseholders, connectors, wiring terminals and display lamps are mounted and prevented from shifting or rotating by the use of lockwashers, starwashers, or other mounting format that prevents turning of the component.

3. Corrosion Protection - All ferrous metal parts are protected against corrosion by painting, plating or the equivalent.

4. Accessibility of Live Parts - All uninsulated live parts in primary circuitry are housed within a non-metallic enclosure constructed with no openings other than those specifically described in Sections 4 and 5.

5. Grounding - No grounding connection provided within the equipment.

6. Internal Wiring - Internal wiring is routed away from sharp or moving parts. Internal wiring leads terminating in soldered connections are made mechanically secure prior to soldering. Recognized Component separable (quick disconnect) connectors of the positive detent type, closed loop connectors, or other types specifically described in the text of this report are also acceptable as internal wiring terminals. At points where internal wiring passes through metal walls or partitions, the wiring insulation is protected against abrasion or damage by plastic bushings or grommets.

7. Markings - The product is marked on as labeling system as described as follows: - manufacturer's name,trade name or trade mark, - model number, - electrical ratings(volts, input current & frequency), - Symbol for Class II equipment. Refer to Illustration No. 1 for details.

8. Cautionary Markings - Refer to Illustration No. 1 for details.

9. Installation, Operating and Safety Instructions - Instructions for installation and use of this product are provided by the manufacturer. When applying in Canada, instructions in both Frenth and English are required. Refer to Illustration No. 5 & 6 for details.

1. Spacing - In primary circuits, 1.0 mm minimum spacing are maintained through air and 1.6 mm over surfaces of insulating material between current-carrying parts of opposite polarity before thermal link, 2.0 mm minimum spacing are maintained through air and 3.2 mm over surfaces of insulating material between such current-carrying parts and low voltage isolated circuits.

Recognized Component - A component part, which has been previously evaluated by an accredited certification body with restrictions and must be evaluated as part of the basic product considering the restrictions as specified by the Conditions of Acceptability.

6.0 Critical Features

Unlisted Component - A part that has not been previously evaluated to the appropriate designated component standard. It may also be a Listed or Recognized component that is being used outside of its evaluated Listing or component recognition.

descriptions. All dimensions are approximate unless specified as exact or within a tolerance. In addition to the specific construction details described in this Report, the following general requirements also apply.

Listed Component - A component part, which has been previously Listed or Certified by an accredited Certification Organization with no restrictions and is used in the intended application within its ratings.

Critical Features/Components - An essential part, material, subassembly, system, software, or accessory of a product that has a direct bearing on the product’s conformance to applicable requirements of the product standard.

Construction Details - For specific construction details, reference should be made to the photographs and

ED 16.3.15 (1-Jan-13) Mandatory

Page 14: Listing Constructional Data Report (CDR) - Logitech · Electrical Wires Factory ... specifically described in the text of this report are also acceptable as internal wiring terminals

Report No. 13070799HKG-001Logitech Inc.

Page 14 of 31 Issued: 5-Sep-2013Revised: None

Illustration 1 - Marking (representative)

7.0 Illustrations

Note: The ETL, CETL logo shall not be less than 8 mm in width and in height, “C” and “US” and the control No. “3121678” shall not be less than 2 mm in height, "Intertek" shall be at least 3 mm in height and “CM” shall be at least 1 mm in height. The “CONFORMS TO UL STD. 60950-1” and “CERTIFIED TO CAN/CSA STD. C22.2 No. 60950-1-07” shall not be less than 1.5 mm in height.

ED 16.3.15 (1-Jan-13) Mandatory

Page 15: Listing Constructional Data Report (CDR) - Logitech · Electrical Wires Factory ... specifically described in the text of this report are also acceptable as internal wiring terminals

Report No. 13070799HKG-001Logitech Inc.

Page 15 of 31 Issued: 5-Sep-2013Revised: None

7.0 Illustrations

Illustration 2 - Circuit diagram

ED 16.3.15 (1-Jan-13) Mandatory

Page 16: Listing Constructional Data Report (CDR) - Logitech · Electrical Wires Factory ... specifically described in the text of this report are also acceptable as internal wiring terminals

Report No. 13070799HKG-001Logitech Inc.

Page 16 of 31 Issued: 5-Sep-2013Revised: None

7.0 Illustrations

Illustration 3 - Circuit diagram

ED 16.3.15 (1-Jan-13) Mandatory

Page 17: Listing Constructional Data Report (CDR) - Logitech · Electrical Wires Factory ... specifically described in the text of this report are also acceptable as internal wiring terminals

Report No. 13070799HKG-001Logitech Inc.

Page 17 of 31 Issued: 5-Sep-2013Revised: None

7.0 Illustrations

Illustration 4 - Circuit diagram

ED 16.3.15 (1-Jan-13) Mandatory

Page 18: Listing Constructional Data Report (CDR) - Logitech · Electrical Wires Factory ... specifically described in the text of this report are also acceptable as internal wiring terminals

Report No. 13070799HKG-001Logitech Inc.

Page 18 of 31 Issued: 5-Sep-2013Revised: None

7.0 Illustrations

Illustration 5 - Circuit diagram for single rectified board separate from alternative amplified board

ED 16.3.15 (1-Jan-13) Mandatory

Page 19: Listing Constructional Data Report (CDR) - Logitech · Electrical Wires Factory ... specifically described in the text of this report are also acceptable as internal wiring terminals

Report No. 13070799HKG-001Logitech Inc.

Page 19 of 31 Issued: 5-Sep-2013Revised: None

7.0 Illustrations

Illustration 6 - Circuit diagram for alternative amplified board

ED 16.3.15 (1-Jan-13) Mandatory

Page 20: Listing Constructional Data Report (CDR) - Logitech · Electrical Wires Factory ... specifically described in the text of this report are also acceptable as internal wiring terminals

Report No. 13070799HKG-001Logitech Inc.

Page 20 of 31 Issued: 5-Sep-2013Revised: None

7.0 Illustrations

Illustration 7 - Circuit diagram for alternative amplified board

ED 16.3.15 (1-Jan-13) Mandatory

Page 21: Listing Constructional Data Report (CDR) - Logitech · Electrical Wires Factory ... specifically described in the text of this report are also acceptable as internal wiring terminals

Report No. 13070799HKG-001Logitech Inc.

Page 21 of 31 Issued: 5-Sep-2013Revised: None

7.0 Illustrations

Illustration 8 - Circuit diagram for alternative amplified board

ED 16.3.15 (1-Jan-13) Mandatory

Page 22: Listing Constructional Data Report (CDR) - Logitech · Electrical Wires Factory ... specifically described in the text of this report are also acceptable as internal wiring terminals

Report No. 13070799HKG-001Logitech Inc.

Page 22 of 31 Issued: 5-Sep-2013Revised: None

7.0 Illustrations

Illustration 9 - Circuit diagram for alternative amplified board

ED 16.3.15 (1-Jan-13) Mandatory

Page 23: Listing Constructional Data Report (CDR) - Logitech · Electrical Wires Factory ... specifically described in the text of this report are also acceptable as internal wiring terminals

Report No. 13070799HKG-001Logitech Inc.

Page 23 of 31 Issued: 5-Sep-2013Revised: None

7.0 Illustrations

Illustration 10 - User manual in English

ED 16.3.15 (1-Jan-13) Mandatory

Page 24: Listing Constructional Data Report (CDR) - Logitech · Electrical Wires Factory ... specifically described in the text of this report are also acceptable as internal wiring terminals

Report No. 13070799HKG-001Logitech Inc.

Page 24 of 31 Issued: 5-Sep-2013Revised: None

7.0 Illustrations

Illustration 11 - User manual in French

ED 16.3.15 (1-Jan-13) Mandatory

Page 25: Listing Constructional Data Report (CDR) - Logitech · Electrical Wires Factory ... specifically described in the text of this report are also acceptable as internal wiring terminals

Report No. 13070799HKG-001Logitech Inc.

Page 25 of 31 Issued: 5-Sep-2013Revised: None

Evaluation Period Project No. SZ09040028

Sample Rec. Date 01 Apr. 2009 Condition Prototype Sample ID.Z09040028-001, Z09040028-002, Z09040028-003

Test LocationTest Procedure

8.0 Test Summary01 Apr. - 28 Apr. 2009/ 25 Mar. - 26 Apr. 2010

Intertek Testing Services Shenzhen Ltd. Kejiyuan BranchTesting Lab

Determination of the result includes consideration of measurement uncertainty from the test equipment and The following tests were performed:Test Description UL 60950-1 2nd Edition, Dated March 27, 2007 & Input current 1.6.2Marking Durability test 1.7.11Finger Test 2.1.1.1bPin Test 2.1.1.1cVoltage under normal conditions test 2.2.2Voltage under fault conditions test 2.2.3Humidity Condition Test 2.9.2Determination of Working Voltage Test 2.10.2Clearances and Creepage Distances Measurements 2.10.3 & 2.10.4Solid Insualtion Measurement 2.10.5.1 & 2.10.5.2Cord Anchorages and Strain Relief Test 3.2.6Mechanical Strength - 10N Force Test 4.2.2Mechanical Strength - 250N Force Test 4.2.4Steel Ball Impact Test 4.2.5Stress Relief Test 4.2.7Temperature rise test 4.5.2Ball Pressure Test 4.5.5

Abnormal Operations and Fault Conditions Test 5.3

Touch Current Test 5.1Electric Strength Test 5.2

ED 16.3.15 (1-Jan-13) Mandatory

Page 26: Listing Constructional Data Report (CDR) - Logitech · Electrical Wires Factory ... specifically described in the text of this report are also acceptable as internal wiring terminals

Report No. 13070799HKG-001Logitech Inc.

Page 26 of 31 Issued: 5-Sep-2013Revised: None

8.0 Test SummaryEvaluation Period Project No. HK13070799Sample Rec. Date 19-Jul-13 Condition Prototype Sample ID. 1001Test LocationTest Procedure

Completed by: Reviewed by:Title: Title:

Signature: Signature:

Touch Current TestElectric Strength Test

Lead Engineer SupervisorMartha Pang

5.2Abnormal Operations and Fault Conditions Test 5.3

Test DescriptionInput Current

Alvin Yeung

8.1 Signatures A representative sample of the product covered by this report has been evaluated and found to comply with the applicable requirements of the standards indicated in Section 1.0.

Temperature rise testBall Pressure Test

Mechanical Strength - 250N Force TestSteel Ball Impact TestStress Relief Test

Determination of the result includes consideration of measurement uncertainty from the test equipment and methods. The product was tested as indicated below with results in conformance to the relevant test criteria.The following tests were performed:

Cerpass Technology CorporationTesting at Manufacturers Premise

19-Jul-2013 to 12-Aug-2013

Voltage under normal conditions testVoltage under fault conditions test

2.10.22.10.3 & 2.10.4

Humidity Condition TestDetermination of Working Voltage TestClearances and Creepage Distances MeasurementsCord Anchorages and Strain Relief TestMechanical Strength - 10N Force Test

4.5.55.1

4.5.24.2.7

3.2.64.2.24.2.44.2.5

UL 60950-1 Second Edition rev. December 19, 2011 and CAN/CSA C22.2 No.60950-1-07 Second Edition, rev. December 19, 2011

2.2.22.2.32.9.2

1.6.2

ED 16.3.15 (1-Jan-13) Mandatory

Page 27: Listing Constructional Data Report (CDR) - Logitech · Electrical Wires Factory ... specifically described in the text of this report are also acceptable as internal wiring terminals

Report No. 13070799HKG-001Logitech Inc.

Page 27 of 31 Issued: 5-Sep-2013Revised: None

BASIC LISTEE

Address

CountryProduct

MULTIPLE LISTEE 1AddressCountry

Brand Name

ASSOCIATED MANUFACTURER

AddressCountry

BASIC LISTEE MODELS

MULTIPLE LISTEE 2AddressCountry

Brand Name

ASSOCIATED MANUFACTURER

AddressCountry

BASIC LISTEE MODELS

MULTIPLE LISTEE 3AddressCountry

Brand Name

ASSOCIATED MANUFACTURER

AddressCountry

BASIC LISTEE MODELS

Speaker System Z313USA

9.0 Correlation Page For Multiple ListingsThe following products, which are identical to those identified in this report except for model number and Listee name, are authorized to bear the ETL label under provisions of the Intertek Multiple Listing Program.

Logitech Inc.

4700NW Camas Meadows DriveCamas, WA 98607,

MULTIPLE LISTEE 2 MODELS

MULTIPLE LISTEE 3 MODELS

None

MULTIPLE LISTEE 1 MODELS

None

None

ED 16.3.15 (1-Jan-13) Mandatory

Page 28: Listing Constructional Data Report (CDR) - Logitech · Electrical Wires Factory ... specifically described in the text of this report are also acceptable as internal wiring terminals

Report No. 13070799HKG-001Logitech Inc.

Page 28 of 31 Issued: 5-Sep-2013Revised: None

10.0 General InformationThe Applicant and Manufacturer have agreed to produce, test and label ETL Listed products in accordance with the requirements of this Report. The Manufacturer has also agreed to notify Intertek and to request authorization prior to using alternate parts, components or materials.

COMPONENTSComponents used shall be those itemized in this Intertek report covering the product, including any amendments and/or revisions.

LISTING MARKThe ETL Listing mark applied to the products shall either be separable in form, such as labels purchased from Intertek, or on a product nameplate or other media only as specifically authorized by Intertek. Use of the mark is subject to the control of Intertek.

The mark must include the following four items:

1) applicable country identifiers "US" and/or "C" or "US", "C" and "EU" 2) the word "Listed" or "Classified" or "Recognized Component" (whichever is appropriate)3) a control number issued by Intertek 4) a product descriptor that identifies the standards used for certification. Example:

For US standards, the words, “Conforms to” shall appear with the standard number along with the word, “Standard” or “Std.” Example: “Conforms to ANSI/UL Std. XX.”

For Canadian standards, the words “Certified to CAN/CSA Standard CXX No. XX.” shall be used, or abbreviated, “Cert. to CAN/CSA Std. CXX No. XX.”

Can be used together when both standards are used.

Note: A facsimile must be submitted to Intertek, Attn: Follow-up Services for approval prior to use. The facsimile need not have a control number. A control number will be issued after signed Certification Agreements have been received by the Follow-up Services office, approval of the facsimile of your proposed Listing Mark, satisfactory completion of the Listing Report, and scheduling of a factory assessment in your facility.

MANUFACTURING AND PRODUCTION TESTSManufacturing and Production Tests shall be performed as required in this Report.

FOLLOW-UP SERVICEPeriodic unannounced audits of the manufacturing facility (and any locations authorized to apply the mark) shall be scheduled by Intertek. An audit report shall be issued after each visit. Special attention will be given to the following:

1. Conformance of the manufactured product to the descriptions in this Report.2. Conformance of the use of the ETL mark with the requirements of this Report and the Certification Agreement.3. Manufacturing changes.4. Performance of specified Manufacturing and Production Tests.

In the event that the Intertek representative identifies non-conformance(s) to any provision of this Report, the Applicant shall take one or more of the following actions:

1. Correct the non-conformance.2. Remove the ETL Mark from non-conforming product.3. Contact the issuing product safety evaluation center for instructions.

ED 16.3.15 (1-Jan-13) Mandatory

Page 29: Listing Constructional Data Report (CDR) - Logitech · Electrical Wires Factory ... specifically described in the text of this report are also acceptable as internal wiring terminals

Report No. 13070799HKG-001Logitech Inc.

Page 29 of 31 Issued: 5-Sep-2013Revised: None

10.1 Evaluation of Unlisted Components

Note to Intertek Follow Up Inspector: The Component Evaluation Center, CEC, will notify you in writing when these components must be selected and sent to the CEC for re-evaluation

Ship the samples to:Intertek Testing Services Hong Kong LimitedETL Component Evaluation CenterUnit H, 3/F., Garment Centre, 576 Castle Peak RoadKowloon, Hong KongAttn: Sample RoomSample Disposition: Due to the destructive nature of the testing, all samples will be discarded at the conclusion of testing unless, the manufacturer specifically requests the return of the samples. The request for return must accompany the initial component

shipment.

Because Unlisted Components are uncontrolled, and they do not fall under a third party follow up program, Intertek may require these components to be tested and/or evaluated at least once annually, more often for certain components, as part of the independent certification process. The Unlisted Components in Section 5.0 require testing and/or evaluation as indicated.

ED 16.3.15 (1-Jan-13) Mandatory

Page 30: Listing Constructional Data Report (CDR) - Logitech · Electrical Wires Factory ... specifically described in the text of this report are also acceptable as internal wiring terminals

Report No. 13070799HKG-001Logitech Inc.

Page 30 of 31 Issued: 5-Sep-2013Revised: None

Product Test Voltage Test TimeAll products covered by this Report. 2000 V 1 s

Dielectric Voltage Withstand Test

11.0 Manufacturing and Production TestsThe manufacturer agrees to conduct the following Manufacturing and Production Tests as specified:

Required Tests

11.1 Dielectric Voltage Withstand TestMethod

One hundred percent of production of the products covered by this Report shall be subjected to a routine production line dielectric withstand test.

The test shall be conducted on products, which are fully assembled. Prior to applying the test potential, all switches, contractors, relays, etc., should be closed so that all primary circuits are energized by the test potential. If all primary circuits cannot be tested at one time, then separate applications of the test potential shall be made.

The test voltage specified below shall be applied between primary circuits and accessible dead-metal parts. The test voltage may be gradually increased to the specified value but must be maintained at the specified value for one second or one minute as required.

Test Equipment

Products Requiring Dielectric Voltage Withstand Test:

The test equipment shall incorporate a transformer with an essentially sinusoidal output, a means to indicate the applied test potential, and an audible and/or visual indicator of dielectric breakdown.The test equipment shall incorporate a voltmeter in the output circuit to indicate directly the applied test potential if the rated output of the test equipment is less than 500VA.If the rated output of the test equipment is 500VA or more, the applied test potential may be indicated by either: 1 - a voltmeter in the primary circuit; 2 - a selector switch marked to indicate the test potential; or 3 - a marking in a readily visible location to indicate the test potential for test equipment having a single test potential output. In cases 2 and 3, the test equipment shall include a lamp or other visual means to indicate that the test potential is present at the test equipment output. All test equipment shall be maintained in current calibration.

ED 16.3.15 (1-Jan-13) Mandatory

Page 31: Listing Constructional Data Report (CDR) - Logitech · Electrical Wires Factory ... specifically described in the text of this report are also acceptable as internal wiring terminals

Report No. 13070799HKG-001Logitech Inc.

Page 31 of 31 Issued: 5-Sep-2013Revised: None

Date/ Project Handler/Proj # Site ID Reviewer

None

12.0 Revision SummaryThe following changes are in compliance with the declaration of Section 8.1:

Section Item Description of Change

ED 16.3.15 (1-Jan-13) Mandatory